If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Costs
EMD
₹ 88,000Document Cost
₹ 500Tender Fee
Refer Documents
Summary
Misc Repairs And Internal Electrification Services, Garden Lights, Replacement Of Unsv Wall Mounted Panels,
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_692028_1Tender No
GE (N)/TOKEN-68/2024-2025Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Supply and fixing warm white 20 meter Mini marathon rope light with connector, IP 65 protection water proof strip light with 72 LEDs/meter offers 400 lumens/meter consuming 6 watt power incl electrically connection complete all as specified and directed. Make: Philips or as equivalent in Halonix /Crompton Greaves /osram /wipro
6
-
-
... More
Supply and fixing of Inverter LED tube light fitting 1x20 Watt with minimum 04 hours battery back integrated aluminium batten with diffuser and including 20 Watt LED hight efficient, AC 220-240 V, 50 Hz and connecting with copper conductor flexible cable of size 0.50 Sqmm from ceiling rose to connector of the light including disconnecting and taking down old existing light fitting of any description and in any position complete all as specified and directed.Make: Philips or as equivalent in Halonix/Crompton Greaves /osram /wipro
50
-
-
... More
S & F LED lamp invertor technology 9 watt with 4 hour power back up with efficiency more than 100 lumen per watt, Lithium ion battery including removing of unserviceable lamp complete all as specified and directed by Engr-in-charge.Make: Philips or as equivalent in Halonix/Crompton Greaves /osram /wipro
120
-
-
... More
S & F modern energy efficient bedroom Muziris wall decorative light of capacity 20 watt single headed 240 volt, IP20 rating, controller type (push button), product weight 1.04 kg, body material (metal), power source (corded electric),Lamp base E27, Colour(bronze) incl electrically connection , including removing of unserviceable decorative light fittings of any description complete all as specified and directed by Engr-in-charge. Make: Philips model No 31425 or as equivalent in Halonix/Crompton Greaves /osram /wipro
25
-
-
... More
S & F modern energy efficient Muziris picture/mirror light of capacity 12 watt 240 volt, Colour (bronze), material (Aluminium), dimensions(mm) 500x80x95, lamp base (LED), CCT 3000K, Lumen 420 lm, CRI80 incl electrically connection , including removing of unserviceable mirror light fittings of any description complete all as specified and directed by Engr-in-charge. Make: Philips model No 31403 or as equivalent in Halonix/Crompton Greaves /osram /wipro
18
-
-
... More
S & F modern energy efficient Bed side light of capacity 2 watt 220-240 volt, Colour (Grey), material (Metal), dimensions(mm) 470x67x28, lamp base (LED), CCT 3000K, Lumen 50 lm,controller type (push button), power source (corded electric) incl electrically connection , including removing of unserviceable bed side light fittings of any description complete all as specified and directed by Engr-in-charge. Make: Philips model No 30975 or as equivalent in Halonix/Crompton Greaves /osram /wipro
14
-
-
... More
S & F modern energy efficient Track light of capacity 20 watt 220-240 volt, Colour (Black), material (Aluminium), dimensions(mm) 158x65x125, lamp base (LED), CCT 3000K, Lumen 1500 lm,controller type (push button), power source ( electric) incl electrically connection , including removing of unserviceable track light fittings of any description complete all as specified and directed by Engr-in-charge. Make: Philips model No 31446 or as equivalent in Halonix/Crompton Greaves /osram /wipro
18
-
-
... More
S & F well designed modern energy garden spike light of capacity 12 watt 220-240 volt, Colour (Anthracite), material (Aluminium), dimensions(mm) 100x75x75, lamp base (LED COB Integrated), CCT 4000K, Lumen 360 lm, IP 65 protection against dust & jet of water from any direction ,controller type (push button), power source (corded electric) incl electrically connection complete all as specified and directed by Engr-in-charge. Make: Philips model No 31385 or as equivalent in Halonix/Crompton Greaves /osram /wipro
20
-
-
... More
S & F Solar LED post top luminaire 20 W of high efficiency poly crystalline Solar Module with maintenance free Lithium battery of having 3 days backup with 2 PIR Sensor with 360 degree coverage , 5700K, IP-65 made of pressure die cast aluminium housing & clear glass complete with all accessories internally prewired wire including electronic driver, connecting with fitting and including disconnecting and taking down existing unsv light fitting complete all as specified and directed by Engr-in-charge.
10
-
-
... More
Supply, Install , testing and commissioning of factory made Wall Mounted LT panel CPRI approved in replacement of old damaged wall mounted LT panels of suitable size for 3 Phase 415 Volts indoor type made out 2 mm thick CRCA sheet of sides of the panel board, insulated with PVC sleaves and coloured with (red, yellow,blue and black) CTR and internal wiring with suitable size of PVC insulated copper wire , , fitted on wall by propererly , thimbling and cable entry boxes with cable gland. and the copper bus bar should be 1.5 time from the main incoming comprising of followings :- NOTE:-All MCCB's used are thermal magnetic overload and short-circuit protection class with adjustable tharmal and magnetic levels.
MCCB 4 pole 200 amps 25 KA - 01 No (incoming)
MCCB 4 POLE 63 amps 25 KA - 04No (outgoing to V TPN DB for light/fan/socket point) Ampere meter (digital type) 0-100 amps with selector switch - 01 No
Volt meter (digital type) 0-500 volts with selector switch - 01 No
Indicator lamp RYB (3 Nos) - 01 Set
4
-
-
... More
Material & labour for replacement of unsv earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to galvanised earth wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron.Earth strip protected by GI pipe 15mm bore(medium grade) and connected to earthing test point as directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm c/c both ways with one handle for lifting made out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing complete all as directed by Engineer-in-Charge and earth testing on completion .
25
-
-
... More
Taking down existing LT panel board (Meter Box) located at Map block and supply and fixing sheet metal enclosure board made of 1.6 mm thick metal sheet and painting 2 coats with synthetic enamel paint over a coat of red oxide primer including Aluminium bus bar of 200Amp rating and fixed with wall for fixing MCCB 4Pole 125 amp and electric meters complete with wiring, fitting and accessories, locking arrangements with handle (adequate size and adequate depth for the following equipments, internal wiring and termination of external cable, lugs and glands and conduits as required) comprising of following. (a) Incoming 125 Amp 4 pole MCCB 25 KA-01 Nos.(Main incomer) (b) Aluminium Bus bar rated 200 Amp capacity. (c) 10Amp DP/SPN MCB-01 No (Outgoing for stair case and garrage) (d) 63 Amp DP/SPN MCB-06 Nos (Outgoing for Qtr meters) (e) Taking down and Refixing of electric meter energy meters single phase 240Volt 40Amps 50HZ -06 Nos.
6
-
-
... More
Supply and fix in replacement of LED post top fitting 40 W powder coated aluminium die cast and spun aluminium with clear/diffused PC cover suitable for landscape lighting 240V, 50 Hz ,AC supply complete with all accessories internally pre wired including provision of 3 core PVC flexible copper conductor from electric supply source to connector of light with degree of protection IP 65,CCT 6500K complete all as specified and directed by Engr-in-charge.
Note: Cost of GI pipe of suitable dia of length 2 feet, grouting holes into pillar and cement work deemed to be included in the rate quoted by contractor
10
-
-
... More
Supply and fix in replacement of LED post top fitting 20W powder coated aluminium die cast and spun aluminium with clear/diffused PC cover suitable for landscape lighting 240V, 50 Hz ,AC supply complete with all accessories internally pre wired including provision of 3 core PVC flexible copper conductor from electric supply source to connector of light with degree of protection IP 65,CCT 6500K complete all as specified and directed by Engr-in-charge.
Note: Cost of GI pipe of suitable dia of length 2 feet, grouting holes into piller and cement work has been included in the rate quoted by contractor
6
-
-
... More
Supply and fix new generation, energy saving, environment friendly, long life aesthetically designed aluminium landscape IP 65 of luminaire for diffused lighting with high power LED as light source LED Bollard pathway lights of capacity 10 watt warm white made up of aluminium pipe UV protected pure polyester powder coated having colour temperature(CCT) 3000K warm white fixed to concrete foundation by means of 3 nos M10 bolts complete all as specified and directed by Engr-in-charge.
Note:- Cost of PCC foundation of suitable height , PVC conduit 25 mm of suitable length, all electrical connection and all other items whichever required for fixing is deemed to be included in the unit rate quoted for this item.
21
-
-
... More
Supply & fixing in repair of PCB unit of suitable size of existing make and description of make (Bajaj, Halonix ) for BLDC ceiling fan of 1200 mm sweep, single phase 240 V complete all as specified and directed by the Eng-in-charge.
Note : PCB will be replaced by concerned OEM only.
20
-
-
... More
Supply and fix incl taking down LED garden light fitting cool/warm white with LED bulb upto 20 watt E27/B22 base cap fitted on the piller with the help of GI pipe of 1 mtr length and PCC up to 250 mm height nut bolts and in stainless steel housing with clear acrylic cover in top section with IP 65 protection class ,connection with 1.5 sqmm 3 core copper cable including making suitable PCC foundation and all electrical connection complete all as directed by Engr-in-charge.
24
-
-
... More
Supply and laying or fixing or passing through pipe 1100 volts grade heavy duty, 2 core, 6 sq mm nominal cross section cable with PVC insulated aluminium conductor multistrand served with an inner sheathing of PVC tape and overall PVC sheathed in service connection, including disconnecting and taking down old unserviceable existing cable complete all as specified and as directed by the Engineer-in-Charge.
800
-
-
... More
Supply and laying or fixing or passing through pipe 1100 volts grade heavy duty, 2 core, 10 sq mm nominal cross section cable with PVC insulated aluminium conductor multistrand served with an inner sheathing of PVC tape and overall PVC sheathed in service connection, including disconnecting and taking down old unserviceable existing cable complete all as specified and as directed by the Engineer-in-Charge.
300
-
-
... More
Supply and fixing 36W , 2’X2’ recessed Luminaire with housing made up of CRCA powder coated made up of High transmittance diffuser for glare free symmetric light distribution., Powered by Isolated, SELV output Electronic Driver with Output Short-circuit protection, Surge Voltage protection and other safety & performance test as per IS:15885 Part 2/Sec 13. Power Consumption should not greater than 36W and System Efficacy not less than 100 Lumens/Watt, CCT 5700K PF0.95, CRI80 ,THD10%. Operating temperature: -10 °C to +35 °C , Operating voltage range: 140 V - 270 V. Built in PIR Sensor. Luminaire Should conform to IP20 Classification. Test report to be submitted; photo biological safety norms: IS16108, test certificate to be submitted; certification: LM 79 for luminaire and LM80 for led source, Driver and Fixture to be BIS certified as in repair complete all as specified and as directed by the Engr-in-charge.
20
-
-
... More
M&L concrete pit in PCC (1:3:6) type C1 of size 40x40x40 cm having hollow inner size 30 cm x 30 cm and pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 4cm reinforced with 8mm dia TMT bars @ 15cm c/c both ways with one handle for lifting made out of 8mm dia bar complete all as specified and directed by Engr-in-Charge.
50
-
-
... More
Material and labour for servicing of earthing on site including filling water, replacement of GI funnel, repair to plaster work white wash etc complete all as directed by Engr-in-charge.
100
-
-
... More
Checking of earthing results of various type of earthing installed in bldgs/Sub station through earth test meter and submission of earthing report complete all as specified and directed by Engr-in-charge.
100
-
-
... More
S&F PVC rigid casing caping 20 mm dia icl fixing clamps complete all as specified and directed by Engr-in-Charge.
100
-
-
... More
Supply and fixing hot pressed module SMC meter junction boxes SMC base and SMC door, concealed hinges, veiwing glass, earth bolt, plugged off white colour suitable for single phase energy meter complete all as specified and directed.
12
-
-
... More
Supply and fix recess mounted LED luminaire 36 watt cool white 5700K suitable for grid ceIling cutout dimensions: 2x2 Ft. incl connecting with twin core copper wire from ceiling rose to fitting, Fixture size: (LxWxH) in (595x595x65) mm incl lamp and driver complete all as directed by Engr-in-charge.
25
-
-
... More
Supply and fix surface mounted LED luminaire 36 watt warm white 3000 K suitable for surface ceiling cutout dimensions: 2x2 Ft. incl connecting with twin core copper wire from ceiling rose to fitting, Fixture size: (LxWxH) in (595x595x65) mm incl lamp and driver complete all as directed by Engr-in-charge.
40
-
-
... More
Supply and fixing Round surface mounting LED Panel 18 watt warm/cool type circular down lighter with PDC aluminium housing and high translucent frosted plastic diffuser, 240 volt, 50HZ, AC supply, efficiency 100lm/w complete with all accessories internally pre wired including connecting with 2 core flexible wire copper conductor from ceiling rose to connector of the light, including disconnecting and taking down existing old unserviceable fitting complete all as specified and as directed by the Engr-in-charge.
60
-
-
... More
Supply and fix in replacement epoxy power coated MCCB distribution box double door VTPN 4 way vertical type AC 415 V with IP 43 protection for MCBs alongwith provision of MCCB as incomer with common bus-bar rated 200 Amp at incoming end of outgoing MCBs grouted/ flush to wall, complete all as directed by Engineer-in-charge. (Note :- MCCB will be measured and paid under seperate item) (i) Cost of Eye/bottle thimbles used MCBs in DBs shall deemed to be included in unit rate quoted for this items, (ii) Electric wiring should be done in proper colour coding i.e. Red for phase, Black for neutral and Green for Earth (iii) Connection of cable with VTPN shall be done through appropriate size of Al thimble.
18
-
-
... More
Supply and fix in replacement of MCCB, 4 Pole, 63 A, 16 KA for fixing in DB including proper thimble connection, thermal and magnetic release protection complete all as specified and directed by Engineer-in-charge.
8
-
-
... More
Supply and fix in replacement of MCCB, 4 Pole, 100 A, 25 KA for fixing in DB including proper thimble connection, thermal and magnetic release protection complete all as specified and directed by Engineer-in-charge.
10
-
-
... More
Supply and fix in replacement of Sheet metal enclosure 8 ways double door for DBs when MCBs are to be used 240,volts including 200 Amps standard bus bar of suitable size and common neutral link all flush mounting type, drilling holes for incoming and out going cables with IP43 protection complete all as specified & directed by Engr-in-charge.
15
-
-
... More
Supply and fix in replacement of Sheet metal enclosure 4 ways double door for DBs when MCBs are to be used 240,volts including 200 Amps standard bus bar of suitable size and common neutral link all flush mounting type, drilling holes for incoming and out going cables with IP43 protection complete all as specified & directed by Engr-in-charge.
8
-
-
... More
Supply and fix in replacement of Sheet metal enclosure 12 ways double door for DBs when MCBs are to be used 240,volts including 200 Amps standard bus bar of suitable size and common neutral link all flush mounting type, drilling holes for incoming and out going cables with IP43 protection complete all as specified & directed by Engr-in-charge.
6
-
-
... More
S & F in replacement of MCB , SPN, 240 Volts ,63 amp for fixing in DBs of including proper thimble connections complete all as specified and directed by Engineer-in-Charge. (Note: MCB should be B or C curve as directed by engineer in charge)
16
-
-
... More
S & F in replacement of MCB , SPN, 240 Volts ,40 amp for fixing in DBs of including proper thimble connections complete all as specified and directed by Engineer-in-Charge. (Note: MCB should be B or C curve as directed by engineer in charge)
13
-
-
... More
S & F in replacement of MCB, single pole 240 volts 6 to 32 Amp capacity for fixing in DB’s including proper thimble connections complete all as specified and directed by Engineer-in-Charge. (Note: MCB should be B or C curve as directed by engineer in charge)
360
-
-
... More
S & F in replacement of MCB, single pole 240 volts 63 Amp capacity for fixing in DB’s including proper thimble connections complete all as specified and directed by Engineer-in-Charge. (Note: MCB should be B or C curve as directed by engineer in charge)
32
-
-
... More
S&F single pole and neutral enclosure with a two pin and earth plug and socket 20 Amp complete with and including one single pole MCB.20 Amp, 10 KA 'B' curve including removing old unserviceable enclosure complete all as specified and as directed by the Engr-in-charge.
30
-
-
... More
M & L for Sub main wiring with two single core 6.0 Sqmm PVC insulated and unsheathed FRLSH ,stranded copper conductor cable drawn through PVC concealed conduit 25 mm dia medium grade including 6.0 Sqmm PVC insulated unsheathed FRLSH stranded copper conductor cable as earth wire all as specified and directed by Engineer-in-charge. Note 1:- 2(two) Runs of 6.00 Sqmm Copper conductor cable, 1 Run of PVC conduit & 1 Run of 6.00 Sqmm Copper conductor Earth wire shall be measured as one unit) Note 2 :(i) Rate quoted for this items shall be inclusive of the cost of (i) Rigid non-metallic PVC conduit of 25 mm dia medium grade with tees, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. (ii) Cutting chases, pinning in making good to facing where required and pointing in cement mortar 1:3 to match the existing surfaces and cutting not exc. 10 cm girth . (iii) Including taking out/down existing unserviceable sub main wiring (iv) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB.
1000
-
-
... More
M & L for Sub main wiring with two single core 4.0 Sqmm PVC insulated and unsheathed FRLSH ,stranded copper conductor cable drawn through PVC concealed conduit 25 mm dia including 4.0 Sqmm PVC insulated unsheathed FRLSH stranded copper conductor cable as earth wire all as specified and directed by Engineer-in-charge. Note 1:- 2 Runs of 4.00 Sqmm Copper conductor cable, 1 Run of PVC conduit & 1 Run of 4.0 Sqmm Copper conductor Earth wire shall be measured as one unit) Note2 : Rate quoted for this items shall be inclusive of the cost of (i) Rigid non-metallic PVC conduit of 25 mm dia with tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. (ii) Cutting chases, pinning in making good to facing where required and pointing in cement mortar 1:3 to match the existing surfaces, cutting not exc. 10 cm girth . (iii) Taking out/down existing unserviceable sub main wiring. (iv) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB.
400
-
-
... More
M & L for Sub main wiring with two single core 10.0 Sqmm PVC insulated and unsheathed FRLSH ,stranded copper conductor cable drawn through PVC concealed conduit 25 mm dia including 6 Sqmm PVC insulated unsheathed FRLSH stranded copper conductor cable as earth wire all as specified and directed by Engineer-in-charge. Note 1:- 2 Runs of 10.00 Sqmm Copper conductor cable, 1 Run of PVC conduit & 1 Run of 6.00 Sqmm Copper conductor Earth wire shall be measured as one unit) Note2 : Rate quoted for this items shall be inclusive of the cost of (i) Rigid non-metallic PVC conduit of 25 mm dia with tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. (ii) Cutting chases, pinning in making good to facing where required and pointing in cement mortar 1:3 to match the existing surfaces, cutting not exc. 10 cm girth . (iii) Taking out/down existing unserviceable sub main wiring. (iv) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB.
300
-
-
... More
M & L for Sub main wiring with 04 (Four) single core 16.0 Sqmm PVC insulated and unsheathed FRLSH ,stranded copper conductor cable drawn through pvc concealed conduit of suitable dia including 10.0 Sqmm PVC insulated unsheathed FRLSH stranded copper conductor cable as earth wire all as specified and directed by Engineer-in-charge. Note1:- 4 Runs of 16.00 Sqmm Copper conductor cable, 1 Run of PVC conduit & 1 Run of 10.00 Sqmm Copper conductor Earth wire shall be measured as one unit) Note2 : Rate quoted for this item shall be inclusive of the cost of (i) Rigid non-metallic PVC conduit of suitable size dia with tees, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. (ii) Cutting chases, pinning in and making good to facing where required pointing in cement mortar 1:3 to match the existing surfaces and cutting not exc. 10 cm girth. (iii) Taking down/out existing unserviceable sub main wiring. (iv) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB.
600
-
-
... More
M & L as in replacement for Sub main wiring (with approved colour coding as per IS) with single core FRLSH PVC insulated multistranded copper conductor 1.5 sqmm (main cable : number of runs indicated below) along with one run of single core FRLSH PVC insulated multistranded copper conductor 1.5 sqmm for earthing in and including PVC conduits of size. Note: (i) 2 runs of 1.5 sq. mm main cable + 1 run of 1.5 Sq. mm earth cable and one run of pvc conduit will be measured as one unit (ii) Two different color wires shall be used for phase and neutral . (iii) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. (iv) If Necessary cutting chasing shall be included in this item.
180
-
-
... More
M & L as in replacement for Sub main wiring (with approved colour coding as per IS) with single core FRLSH PVC insulated multistranded copper conductor 2.5 sqmm (main cable : number of runs indicated below) along with one run of single core FRLSH PVC insulated multistranded copper conductor 2.5sqmm for earthing in and including PVC conduits of suitable size, Note: (i) 2 runs of 2.5 sq. mm main cable + 1 run of 2.5 Sq. mm earth cable and one run of pvc conduit will be measured as one unit. (ii) Two different color wires shall be used for phase and neutral . (iii) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. (iv) If Necessary cutting chasing shall be included in this item.
180
-
-
... More
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for laying of cables including getting out in any kind of soil complete all as specified and directed.
150
-
-
... More
Returning filling in including spreading, levelling, and well ramming, in layers not exceeding 25 cm thick each layer of any kind of soil.
100
-
-
... More
Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point.
50
-
-
... More
Material and labour for sand cushioning for cables 8 cm below the cable and 15 cm above with dry river sand in trenches for cushioning of underground cable line including spreading, leveling, well ramming completed all as specified and directed. Note: Punning down thickness shall be measured for payment.
45
-
-
... More
Supplying & laying factory made unreinforced Precast concrete cable covers class LV type 1, flat, Size 250x150x40mm laid in trenches as protection to cables complete all as directed by Engr-in-Charge
3276
-
-
... More
Material and labour for replacement of GI tubing light grade 40 mm bore for passing through cables under the floor ,along the wall or along the pole complete all as specified and directed.
40
-
-
... More
Material and labour for replacement of GI tubing light grade 80 mm bore for passing through cables under the floor ,along the wall or along the pole complete all as specified and directed.
10
-
-
... More
S&F XLPE Insulated ,screened, PVC bedded, galvanized steel wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core supplied & laid in replacement complete all as specified& directed by Engineer-in-Charge.
300
-
-
... More
S&F XLPE Insulated ,screened, PVC bedded, galvanized steel wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core supplied & laid in replacement complete all as specified& directed by Engineer-in-Charge.
300
-
-
... More
S&F XLPE Insulated ,screened, PVC bedded, galvanized steel wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3.5 core supplied & laid in replacement complete all as specified& directed by Engineer-in-Charge.
180
-
-
... More
Supply installation, testing and commissioning LT Feeder pillar board out door type cubicle panel board suitable for 3 phase,4 wire 415 volt 50 hz factory febricated approved CPRI powder coated made out of 3.15 mm thick CRCA sheet and MS angle iron section 60X60X6mm frame with front and back openable double door system with locking arragement louver and air vent gasket for netural flow of air with canopy, inner compartment made out of 2 mm thick CRCA sheet duly compartmentalized for each MCCB of incoming and outgoing with lockable arragement with aluminium bus bar three phase and neutral of capacity of 400 amp marked red, yelllow, black and blue inslulators, made of high strength insulated material suitable 1100 voltage all controll PVC wires shall be with 2.5 sq mm multistrand copper conductor and shall be properly bunched, tied, frerruled for proper indication , fixed on PCC foundation complete with following accessories:- Note:- (i) LT panel maker shall comply the IS/IEC-61439 (Part-1) : 2011 & IS/IEC-61439 (Part-2) : 2011 (ii) cost of PCC foundation is included in the unit rate quoted by contractor. INCOMING:- (a) MCCB 250 Amps, adjustable thermal and magnetic type 4 pole, 415 Volts, 36 KA -01 Nos (Ultimate breaking capacity ICs -Icu = 100 %) .
OUT GOING:- (a) MCCB 100 amps, 415 volts ,4 Pole breaking capacity 25 KA --- 06 Nos + 01 Nos spare
(b) 4 Pole On-Load changeover switch 100 Amps --- 01 Nos
(c) Digital type Volt meter 0-500 Volts square type with selector switch - 01 No.
(d) CT of suitable size
(e) Digital type Ammeter 0-400 Amps square type with selector switch - 01 No.
(f) Wiring complete with copper wire of suitable size (g) Indicator lamp LED type, set of three marked red, yellow & blue - 01 Set.
(h) Cable glands brass of suitable size for cable.
1
-
-
... More
Supply and fix in replacement of New generation energy saving and environmental friendly long life LED building security light 1x25 watts made up of pressure die cast alluminium housing with high power LED as light source and lense embedded PC cover having TOP OPENING separate driver compartment with IP66 protection and impact resistance of IK07, with all accessories including suitable bracket with 32 mm bore light grade GI pipe bend to shape, including MS clamp of size of required size and PVC cable 1.5 Sqmm twin core from ceiling rose to light fittings complete all as specified and directed by Engineer-in-charge.
50
-
-
... More
Supply and fixing in replacement of LED surface mounted bulk head luminaries 8-10 watt with min 800 lumen, IP 66, PVC housing, surge protection including driver & LED lamp etc complete with all accessories, connecting with copper conductor flexible cable from ceiling rose to connector of the light as in repair complete all as specified and as directed by the Engineer-in-Charge.
50
-
-
... More
Taking down carefully existing points wiring on surface conduit/concealed conduit for light/ fan/socket /power/ bell from wall & roof along with fitting and fixtures such as switches, sockets, ceiling roses, batten holders, unserviceable light fittings, piece of wires,gutties, conduit, wooden boards etc and making good the disturbed portion of walls, ceiling etc all as specified and directed Engr-in-charge.
1490
-
-
... More
M & L for Point wiring with 1.5 sqmm PVC insulated and unsheathed FRLSH single core multi-stranded copper conductor for one light/fan in new PVC conduit to be terminated in pressed steel terminal boxes with top cover plate including 1.5 sqmm PVC insulated and unsheathed FRLSH single core multi-stranded copper earth continuity conductor connected to cmmon earth dolly controlled by one switch and/or one regulator complete including repairing the surfaces in CM 1:3 and finishing the surface as per existing treatment all as specified and directed by Engineer in-charge Note-I-(Switches and regulators shall be measured and paid for separately). Note-II- ( Wiring shall be done as per colour code in IS for phase, neutral and earth). Note-III- (The cost of modular cover plate, blank plate and metal flush boxes is deemed to be included in the unit rate quoted for this item). Note -IV - cost of Eye/bottle thimbles used for connection in switches/sockets & MCBs in DBs is deemed to be included in the unit rate quoted for this item. Note:- V- Rate of cutting chasing included in the unit rate quoted for this item
500
-
-
... More
M & L for point wiring with 1.5 sqmm PVC insulated and unsheathed FRLSH single core multi-stranded copper conductor for one light point controlled by 2 way and including PVC rigid concealed conduit medium grade 19/20 mm dia to be terminated in pressed steel terminal boxes with top cover plate including 1.5 sqmm PVC insulated and unsheathed FRLSH single core multi-stranded copper earth continuity conductor connected to cmmon earth dolly controlled by one switch and/or one regulator complete including repairing the surfaces in CM 1:3 and finishing the surface as per existing treatment all as specified and directed.Note-I- ( Wiring shall be done as per colour code in IS for phase, neutral and earth). Note-II- (The cost of modular cover plate, blank plate and metal flush boxes is deemed to be included in the unit rate quoted for this item). Note -III - cost of Eye/bottle thimbles used for connection for 2 way switch is deemed to be included in the unit rate quoted for this item. Note:-III- Rate of cutting chasing included in the unit rate quoted for this item
20
-
-
... More
All as per Sl item No 63.00 above herein before but one socket out let 5 pins 5 Amp on the same board with other switches complete all as specified and directed.
65
-
-
... More
All as per Sl item No 63.00 above herein before but for one socket out let 5 pins 5 Amp on independent board complete all as specified and directed.
70
-
-
... More
All as per item No. 63.00 herein before but 2.5 Sqmm PVC insulated and unsheathed FRLSH single core multistranded copper conductor incl 2.5 Sqmm PVC insulated and unsheathed FRLSH single core muilti-stranded copper earth wire for switch socket combination 3 pin 15 amps on independent board.
60
-
-
... More
M & L for Point wiring with 1.5 sqmm PVC insulated and unsheathed FRLSH single core multi-stranded copper conductor for one light/fan in existing conduit to be terminated in pressed steel terminal boxes with top cover plate including 1.5 sqmm PVC insulated and unsheathed FRLSH single core multi-stranded copper earth continuity conductor connected to cmmon earth dolly controlled by one switch and/or one regulator complete including repairing the surfaces in CM 1:3 and finishing the surface as per existing treatment all as specified and directed by Engineer iin-charge Note-I-(Switches and regulators shall be measured and paid for separately). Note-II- ( Wiring shall be done as per colour code in IS for phase, neutral and earth). Note-III- (The cost of modular cover plate and metal flush boxes is deemed to be included in the unit rate quoted for this item). Note -IV - cost of Eye/bottle thimbles used for connection in switches/sockets & MCBs in DBs is deemed to be included in the unit rate quoted for this item.
580
-
-
... More
All as per Sl item No 68.00 above herein before but one socket out let 5 pins 5 Amp on the same board with other switches complete all as specified and directed.
70
-
-
... More
All as per Sl item No 68.00 above herein before but for one socket out let 5 pins 5 Amp on independent board complete all as specified and directed.
70
-
-
... More
All as per item No 68.00 herein before but 2.5 Sqmm PVC insulated and unsheathed FRLSH single core multistranded copper conductor incl 2.5 Sqmm PVC insulated and unsheathed FRLSH single core muilti-stranded copper earth wire for switch socket combination 3 pin 15 amps on independent board.
55
-
-
... More
Supply and fix in replacement of Modular switch 1 way, 6 Amps, 1 module complete all as specified and directed by Engr-in-charge.
1490
-
-
... More
Supply and fix in replacement of Modular switch 1 way, 16 Amps, 1 module complete all as specified and directed by Engr-in-charge.
165
-
-
... More
Supply and fix in replacement of Modular switch 2 way, 6 Amps, 1 module complete all as specified and directed.
40
-
-
... More
Supply and fix in replacement of Modular Bell switch 1 way, 6 Amps, 1 module complete all as specified.and directed by Engr-in-charge.
15
-
-
... More
S & F Bell ding dong electronic complete all as specified and directed by Engineer-in-charge.
15
-
-
... More
Supply and fix in replacement of Modular socket 5 pin 6 Amps, 2 module complete all as specified and directed by Engr-in-charge.
375
-
-
... More
Supply and fix in replacement of Modular socket 5 pin 6/16 Amps, combination type 2 module complete all as specified and directed by Engr-in-charge.
165
-
-
... More
Supply and fix in replacement of Fan regulator modular type 2 module complete all as specified and directed by Engr-in-charge.
70
-
-
... More
Ceiling rose surface bakelite surface 65 x 50mm 3 terminals all as specified & directed by Engr-in-charge.
550
-
-
... More
Material and labour for in replacement angular type lamp holder, PVC/ polycarbonate type with back plate suitable for 7 to 23 watts for batten fitting, including plastic square board of required size, complete all as specified and directed.
80
-
-
... More
S&F Ceiling/surface mounted Slim design LED round Downlight with Superior light output and internal driver 9/10 Watts 230 volts with internally pre-wired and including connecting up with two core twisted flexible copper conductor cable with suitable size compelte all as specified and directed by Engineer-in-Charge.
45
-
-
... More
S & F LED high bay/medium bay luminaire 80 watt with external electronic driver , IP-65,indoor type input voltage range 120-270 volts with provision of 3 core copper conductor cable 1.5 Sqmm size from connector/ceiling rose to fitting with fixing arrangement as per site requirement/conditions and including removing old unserviceable fitting complete all as specified and as directed by the Engr-in-charge.
8
-
-
... More
S & F LED high bay/medium bay luminaire 120 watt with external electronic driver , IP-65,indoor type input voltage range 120-270 volts with provision of 3 core copper conductor cable 1.5 Sqmm size from connector/ceiling rose to fitting with fixing arrangement as per site requirement/conditions and including removing old unserviceable fitting complete all as specified and as directed by the Engr-in-charge.
9
-
-
... More
S & F in replacement of MCB, TRIPLE pole & neutral (TPN) 10 KA 240 volts 40 to 63 Amp capacity fixing in DB’s complete all as specified and directed. (Note: MCB should be B or C curve all as directed by engineer in charge)
10
-
-
... More
S & F in replacement of Sheet metal enclosure DB TPN 4 ways double door 415 volts with 200 Amps standard bus bar of suitable size and common neutral link flush mounting type, drilling holes for incoming and out going cables complete with IP-43 protection complete all as specified and directed by Engr-in-charge
6
-
-
... More
Supply and fixing LED batten fitting 20 watt, 4 feet, PVC housing with electronic driver cool/warm type complete connecting with copper conductor flexible cable from ceiling rose to connector of the light as in repair complete all as specified and as directed by the Engineer-in-Charge.
320
-
-
... More
Supply and fixing LED batten fitting 10 watt, 2 feet, PVC housing with electronic driver, including LED luminaire 10 watt cool/warm type connecting with copper conductor flexible cable from ceiling rose to connector of the light as in repair complete all as specified and as directed by the Engineer-in-Charge.
80
-
-
... More
S&F as in repair 9/12 watt LED light fitting wall mounting fixture wooden finish (sketch type) including LED lamp 9 watt compact and energy efficient epoxy powder coated luminaire and connecting with copper conductor flexible cable from ceiling rose to connector of the light complete including removing unserviceable light fittings all as specified and as directed by the Engineer-in-Charge.
60
-
-
... More
Cutting of hardstanding floor/wall for laying of cable including matching with suface by using cement concrete all as specified and directed.
Note:- Necessary concrete work to be measured and paid separately.
45
-
-
... More
Supply and fix in replacement of metal flush box of 2 module in MAP qtrs complete all as specified and directed.
50
-
-
... More
Supply and fix in replacement of metal flush box of 3 module in MAP qtrs complete all as specified and directed.
60
-
-
... More
Supply and fix in replacement of metal flush box of 4 module in MAP qtrs complete all as specified and directed.
60
-
-
... More
Supply and fix in replacement of metal flush box of 6 module in MAP qtrs complete all as specified and directed.
50
-
-
... More
Supply and fix in replacement of metal flush box of 8 module in MAP qtrs complete all as specified and directed.
60
-
-
... More
Supply and fix in replacement of modular cover plate of 2 module in MAP qtrs complete all as specified and directed.
50
-
-
... More
Supply and fix in replacement of modular cover plate of 3 module in MAP qtrs complete all as specified and directed.
120
-
-
... More
Supply and fix in replacement of modular cover plate of 4 module in MAP qtrs complete all as specified and directed.
60
-
-
... More
Supply and fix in replacement of modular cover plate of 6 module in MAP qtrs complete all as specified and directed.
50
-
-
... More
Supply and fix in replacement of modular cover plate of 8 module in MAP qtrs complete all as specified and directed.
60
-
-
... More
Material and labour for PCC 1:3:6 type C-2 using 20 mm graded stone aggregate for certain works like (filling tha gap around DB VTPN) including neccassory form work and finishing the surface fair and even without using extra cement all as directed and specified.
5
-
-
... More
Supply and fix epoxy power coated MCCB distribution distribution box double door VTPN 6 way vertical type AC 415 V with IP 43 protection for MCCBs alongwith provision of MCCB as incomer with common bus-bar rated 300 Amp at incoming end of outgoing MCCBs grouted/ flush to wall, complete all as specified by Engineer-in-charge comprising of followings:-
INCOMING:- (a) MCCB 200 Amps, adjustable thermal and magnetic type 4 pole, 415 Volts, 25 KA -01 Nos (Ultimate breaking capacity ICs -Icu = 100 %) .
OUT GOING:- (a) MCCB 63 amps, adjustable thermal and magnetic type 4 pole, 415 Volts, 16 KA --- 06 Nos. (Note : (i) Cost of Eye/bottle thimbles used MCCBs in VTPN 6 way shall deemed to be included in unit rate quoted for this items, (ii) Electric wiring should be done in proper colour coding i.e. Red for phase, Black for neutral and Green for Earth (iii) Connection of cable with VTPN shall be done through appropriate size of Al thimble incl disconnecting and taking down old unsv MCCB DB VTPN of any description.
4
-
-
... More
M & L for Sub main wiring with 04 (Four) single core 10.0 Sqmm PVC insulated and unsheathed FRLSH ,stranded copper conductor cable drawn through pvc concealed conduit of suitable dia including 6.0 Sqmm PVC insulated unsheathed FRLSH stranded copper conductor cable as earth wire all as specified and directed by Engineer-in-charge. Note1:- 4 Runs of 10.00 Sqmm Copper conductor cable, 1 Run of PVC conduit & 1 Run of 6.00 Sqmm Copper conductor Earth wire shall be measured as one unit) Note2 : Rate quoted for this item shall be inclusive of the cost of (i) Rigid non-metallic PVC conduit of suitable size dia with tees, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. (ii) Cutting chases, pinning in and making good to facing where required pointing in cement mortar 1:3 to match the existing surfaces and cutting not exc. 10 cm girth. (iii) Taking down/out existing unserviceable sub main wiring. (iv) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB.
200
-
-
... More
Labour only for removing/refixing AMA LED Elevated Heliport Light and checking serviceability of AMA LED Elevated Heliport Light ,Isolation Transformer and Primary/Secondry connectors with the help of suitable equipment and reassemble the same after replacement of unserviceable componnent and testing complete all as directed at site by Engr-in-Charge. Note:- Unserviceable components like Isolation transformer,LED Light,Primary connector and Secondry connector will be measured and paid separatly under below mention schedule
22
-
-
... More
Material & labour for Isolation Transformer 45 Watt, 50 Hz, 5000V grade primery/secondry 6.6 A/6.6A all as specified and directed by Engr-In-Charge
Make:- India Isolation Transformer or Equivalent in Crompton Greaves/Alstom/Kotsons.
10
-
-
... More
Material & labour for LED Elevated Heliport Light all as per existing installed at helipad make of AMA INDIA complete all as specified and directed by Engr-In-Charge
Note:- Prior to placing order for supplyof heliport lights colour of the light will be approved from AO/Engr-in-Charge
Make:- AMA India(As per existing only)
10
-
-
... More
Material and labour for Primary Connector for connection of LED Helipad Light with transformer complete all as specified and directed.
10
-
-
... More
Material and labour for Secondry Connector for connection of LED Helipad Light with transformer complete all as specified and directed.
10
-
-
... More
Supply and fixing in replacement cable junction boxes IP66 with integrated membrane/metric knockouts for cable entry of size130 mm x 180 mm x 77 mm, all as per Hensel cat part DK1010G of Hensel or equivalent in HPL/ADHUNIK SWITCHGEAR, having arrangement of connecting incoming and outgoing cables including suitable gland of PVC and fixing arrangements with flood lights complete all as directed by Engr-in-charge.
12
-
-
... More
Periodical inspection by qualified team for LED Elevated Heliport Light system complete installed at Patiala cantt incl repair/ replacement of unserviceable/ defective accesories if any and as mentioned below:
1. CCR Panel 8 kVA, Make: NASU systems year of installation 2018
2. Underground cable 16 SQMM PVC sheathed stranded copper conductor single core airport light cable of 5 KV grade: Approx 2400 RM
3. CI housing boxes and LED Elevated Heliport Lights with connected componnents like Isolation transformer,LED Light, Primary connector and Secondry connector: 54 Nos
Note 1 : Contractor should inspect the system once in two months or as called upon by Engineer- in -charge. The inspection and repair should incl complete testing of system, rectification of faults occured due to moisture etc incl taping of joints minor repair of the CCR panel. Accesories/materials for insulation and water proofing incl tapes, water proofing compound are deemed to be incl in this item. If any Major repair is required the same is to be informed by the contractor alongwith cost to be occured. Unserviceable components like Isolation transformer,LED Light,Primary connector and Secondry connector will be measured and paid separatly.
Note 2 : Contractor is advised to visit the complete site prior bidding. Contractor should visit the site upon notification within 24 hrs. Any delay thereafter shall results in penalty of Rs 500/ day.
2
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%