If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Costs
EMD
₹ 60,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2020_MES_343684_1Bid Award Id
ViewTender No
GE/BHI-13/2020-21Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
One light/fan/bell point controlled by one switch 6 amp one way
700
-
-
... More
One 3 pin switch socket combination 6 amp on the independent board.
190
-
-
... More
One 3 pin switch socket combination on same board with other switches.
170
-
-
... More
All as decribed above but one light point controlled by two-2 way switch.
35
-
-
... More
All as described above but point wiring with 2.5 sqmm single core multi stranded copper conductor PVC insulated & unsheathed cable 1100 volt grade and 1.5 sqmm PVC insulated and unsheathed cable 1100 volt grade with multi stranded copper conductor for earth wire for 15/16 amp multi purpose socket combination point on independent board.
165
-
-
... More
M&L switch piano flush type single pole, one way 6amp .
528
-
-
... More
M&L switch piano flush type two way 5/15 amp .
70
-
-
... More
M&L switch piano flush type single pole, one way 15 amp .
145
-
-
... More
M&L socket outlet piano flush type 3 pin 5 amp.
330
-
-
... More
M&L socket outlet piano flush type 3 pin 15 amp.
145
-
-
... More
S/fix fan regulator electronic socket type .
80
-
-
... More
M&L switch flush type bell push button 6 amp .
30
-
-
... More
S&F modular white cover plate with frame, 1 module/2 module.
12
-
-
... More
S&F modular white cover plate with frame, 3 module.
10
-
-
... More
S&F modular white cover plate with frame, 6 module.
18
-
-
... More
S&F modular white cover plate with frame, 8 module.
10
-
-
... More
S&F Metal Flush boxes 1/2 module
12
-
-
... More
S&F Metal Flush boxes 3 module.
10
-
-
... More
S&F Metal Flush boxes 6 module.
18
-
-
... More
S&F Metal Flush boxes 8 module.
10
-
-
... More
M&L modular switch 1 way 6 A, 1 module.
130
-
-
... More
M&L modular bell push switch, 6 A, 1 module.
12
-
-
... More
M&L modular socket, 6A-2/3 pin combined, 2 module.
30
-
-
... More
M&L modular switch 16 Amps, 1 module with indicator.
20
-
-
... More
M&L modular socket 16 Amps, 6 pin, 2 module
20
-
-
... More
S&F modular fan step regulator, 120W - 1 module.
18
-
-
... More
S&F bell Buzzer AC 230Volts single pole.
12
-
-
... More
S&F bell Ding dong AC 230Volts single pole.
60
-
-
... More
S/fix ceiling rose 65x17mm three terminals after dismantling old one.
540
-
-
... More
S& F lamp holder,PVC/Polycarbonate type and back plate suitable for batten fitting.
180
-
-
... More
Taking down carefully copper / Aluminium wiring and removing materials from site as directed
680
-
-
... More
M&L submain wiring with 2 runs of copper conductor PVC insulated unsheathed cable 1100 volt grade 4 sqmm drawn through PVC conduit medium grade ISI marked 25mm dia as per IS specification fixed concealed in wall/ceiling including conduit and conduit accessories and incl provn of PVC insulated 2 Sqmm multistranded copper conductor as earth continuity conductor connected to earth dolly all as specified including dismantling old and making good to the disturbed surface by plastering and two coat of distamper all as directed at site Note : Two runs of 4 sqmm cable alongwith one run of 2 Sqmm PVC insulated unsheathed copper conductor as earth wire, conduit and conduit accessories will be measured as one length).
250
-
-
... More
M&L submain wiring with 2 runs of copper conductor PVC insulated unsheathed cable 1100 volt grade 6 sqmm drawn through PVC conduit medium grade ISI marked 25mm dia as per IS specification fixed concealed in wall/ceiling including conduit and conduit accessories and incl provn of PVC insulated 4 Sqmm multistranded copper conductor as earth continuity conductor connected to earth dolly all as specified including dismantling old and making good to the disturbed surface by plastering and two coat of distamper all as directed at site Note : Two runs of 6 sqmm cable alongwith one run of 4 Sqmm PVC insulated unsheathed copper conductor as earth wire, conduit and conduit accessories will be measured as one length).
350
-
-
... More
S/Fix MCB DB TPN 4 Way vertical tupe factory made IP 43 protection class metal double door with Shrouded Neutral Bar & Pan assembly with connecting link complete including one MCCB upto 125A after dismantling old one.
20
-
-
... More
S/Fix MCB DB SPN 8 Way factory made IP 43 protection class metal double door with 200 Amp rating bus bar 240/430V for fixing of MCBs/Isolators/RCCBs etc completed.
45
-
-
... More
S/Fix MCB DB SPN 4 Way factory made IP 43 protection class metal double door with 200 Amp rating bus bar 240/430V for fixing of MCBs/Isolators/RCCBs etc completed.
4
-
-
... More
S&F MCCB 125 Amp 16 KA for fixing in DB all as directed by Engr-in-Charge.
10
-
-
... More
S&F MCCB 63/100 Amp 16 KA for fixing in DB all as directed by Engr-in-Charge.
10
-
-
... More
S&F MCBs 240/415 Volts 10 KA finger proof terminal, B curve bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI marked to be fixed on DB . (DB will be measured and paid separately under respective items of sch A):-
-
-
-
... More
MCB SPN 5 to 32 Amps.
45
-
-
... More
MCB SP 5 to 40 Amps
345
-
-
... More
M&L in repar earthing complete with galvanized steel earth plate electrode 600x600x6.3 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level,the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all side and including connected toand including galvanized earth lead wire 4.0 mm dia upto 7.5 mtrs long by means of nuts and bolts, check nuts and washers of GI and connected to earhing test point and earth dolly all as shown in electrical plate No 3 of MES SSR part I and testing on completion including necessary excavation and earth work in any type of soil,PCC(1:3:6)type C1 chamber,pre-cast RCC slab 50mm thic in cement concrete (1:2:4),type B1,reinforced with welded steel wire fabric or XPM,(weight not less than 4 Kg per Sqm) with cast iron frame,funnel with watering pipe 20mm dia medium grade,wire mesh and lugs,GI protection pipe,15mm dia,light grade,7.5 mtr long for protection of earth lead upto test point etc all as specified and as directed.
25
-
-
... More
Collecting Fans from Storeyard of AGE E/M, ceiling /exhaust/wall mounted fans of any size and any make/model,moving to reputed workshop as directed by GE/Engineer-in-charge , dismantaling the same , cutting and removing the old defective/burnt out winding, cleaning the core of the fan motor, re-winding the fan motor by using machine with supper enemelled copper winding wire and using insulating materials, varnishing the assembly and re-assembling the fan including testing etc. complete all as specified and directed by Engineer-in-charge. MAKE of winding wire : Devi Dayal/Chetak/HTP Thulax. NOTE: All defective / unserviceable parts/items other than winding wire,varnish ,insulating material, bearings, capacitors, and flexible wires shall be measured separately and paid for under respective item of this schedule.
-
-
-
... More
All as per item No. 39 here-in-before but for ceiling fans of 1400 mm sweep any type
100
-
-
... More
All as per item No.39 here-in-before but for ceiling fans of 1200 mm sweep any type
250
-
-
... More
All as per item No.39 here-in-before but for exhaust fans of 230/300 mm sweep any type complete all as specified and directed by Engineer in charge.
100
-
-
... More
All as per item No.39 here-in-before but for exhaust fans of 400/450 mm sweep any type complete all as specified and directed by Engineer in charge.
30
-
-
... More
All as per item No.39 here-in-before but for wall mounted fans of upto size 400/450 mm sweep complete all as specified and directed by Engineer in charge.
10
-
-
... More
Disconnecting electric connection and taking down carefully ceiling fans/walls fan/exhaust fan/Aircirculator fan any sweep and removing fan and fan blades to AGE E/M storeyard as directed by Engr-in-Charge
500
-
-
... More
Fixing ceiling fan of any sweep to same site after repair/servicing including flexible cable from ceiling rose to fan complete all as specified and as directed by Engineer-in-Charge
350
-
-
... More
Fixing exfaust fan of any size to same site after repair/servicing including flexible cable from ceiling rose to fan complete all as specified and as directed by Engineer-in-Charge
150
-
-
... More
Servicing, overhauling ,oiling, greasing,checking nut-bolts etc. at store yard complete and re-assembling the fans including testing etc. complete all as specified and directed by Engineer-in- Charge
350
-
-
... More
Servicing, overhauling ,oiling, greasing,checking nut-bolts etc. at site complete and re-assembling the ex fans including testing etc. complete all as specified and directed by Engineer-in- Charge
150
-
-
... More
S&F in repair Capacitor 2.5 mfd fixed in replacement complete all as specified and directed by Engineer-incharge.
280
-
-
... More
S&F in repair Capacitor 3.15 mfd fixed in replacement complete all as specified and directed by Engineer-incharge.
70
-
-
... More
S&F in repair Capacitor 4 mfd fixed in replacement complete all as specified and directed by Engineer-incharge.
150
-
-
... More
S&F in repair Ceiling fan blades (Set of three blades) suitable for 1200/1400 mm sweep ceiling fan duly painted with synthetic enemelled paint fixed in replacement complete all as specified and directed.
80
-
-
... More
S&F in repair Exhaust fan blades (Set of three blades) suitable for 400/450 mm sweep duly painted with synthetic enemelled paint fixed in replacement complete all as specified and directed.
5
-
-
... More
S & F in repair Exhaust fan blades (Set of three blades) suitable for 230/300 mm sweep duly painted with synthetic enemelled paint fixed in replacement complete all as specified and directed.
40
-
-
... More
S&F in repair MS clamps for ceiling fans complete with rubber real of any size/make/sweep/model fixed in replacement complete all as specified and directed by Engineer-incharge.
160
-
-
... More
M&L for suitable size of bolts, nuts,body screws, GM bushes and safety pin/split pins for any type/size/make and model of extg fan as required , fixed in replacement , complete all as specified and directed.
60
-
-
... More
Lathe work/machine work for fitting/housing of in bottom/top cover of fans of any size/ type/ model complete all as specified and directed.
20
-
-
... More
Shaft for any type/size/make and model of fans as required fixed in replacement , complete all as specified and directed.
150
-
-
... More
M&L for painting with two coats of white synthetic enamel paint and marked MES no by black permanent marker all as directed by Engr in Charge.
990
-
-
... More
S&F in repair Ball bearing of ceilling fans of any sweep/size/ make/model fixed in replacement complete all as specified and directed by Engineer-incharge.
80
-
-
... More
S&F in repair Ball bearing of Exhaust fansof any sweep/size/make /model fixed in replacement complete all as specified and directed by Engineer-incharge.
35
-
-
... More
S&F in repair Upper and lower canopy complete with adjusting screws as required, fixed in replacement complete all as specified and directed by Engineer-incharge.
80
-
-
... More
S&F in repair Down rod 20 mm dia, GI tubing medium grade 45 cm to 60 cm long as require fixed in replacement at site complete all as specified and directed.
90
-
-
... More
S&F in repair Louvers made of GI Sheet, suitable for 450 mm sweep exhaust fans fixed in replacement complete all as specified and directed.
10
-
-
... More
S&F in repair Louvers made of GI Sheet, suitable for 230/300 mm sweep exhaust fans fixed in replacement complete all as specified and directed.
60
-
-
... More
S&F 3 phase 4 wire AC Static Energy meter of Accuracy Class 1.0, 3 X 240V, 50Hz, with Backlit LCD Display, of rating 10-60A (Measures & Displays kWh,V,I,kW,PF,Hz,Last month history of kWh & MD in kW) with special features like Display in absence of Power with Transparent Hinge type Box all as specified and directed by engr-in-charge.
30
-
-
... More
S&F single phase AC Static Energy meter of Accuracy Class 1.0, 240V, 50Hz, with Backlit LCD Display of rating 5-30A & with 1 push button. (Measures & displays kWh,kVAh, V,I,PF, frequency, kW, kVA, six months history of Energy & MD in kW & kVA) with transparent hinge box complete all as specified and directed by engr-in-charge.
60
-
-
... More
M&L for taking proper shut down from power house before disconnecting the cable and reconnecting the cable before clearing shut down carrying out following works as directed by engr in charge Note U/S Item like MCB,MCCB will be measured and paid separately
(a) Cleaning of DB by air blower
(b) Cleaning of terminal of MCCB by CRC 26 sprays
(c) Cleaning of bus bar by CRC 26 sprays
(d) Fixing naked wire through flexible pipe
(e) Fixing PVC cable lugs of different size to MCB
(f) Fixing nut bolts if required and make good disturbed surface by plastering and welding hinges of DB door/ Box of DB
25
-
-
... More
M&L for checking insulation resistance of electrical wiring by insulation resistance tester (Megger of DC 500 V) in presence of JE E/M / AGE E/M by taking proper shut down from power house all as specified and directed by engr in charge. Note : cost of Tester & other T&P provided by contractor are deemed to be included in quoted cost.
(a) Before carrying out test it will be contractor responsibility to ensure that all users appliance must be disconnected from electrical circuit. If negligence made by contractor during test, any damage made to user's appliance will be repaired without any cost.
(b) Insualtion reisistance test should be carried out as per IS specification. If insulation resistance of wiring found less than 1 MΩ, rewiring will be measured and paid separately.
(c) during testing if any damage to wiring and connected items done by contractor will be make good by contractor with any cost.
(d) A register to be maintained by contractor should be submitted to AGE E/M sub divn on regular basis.
762
-
-
... More
Supplying and fixing 1100 Volts grade heavy duty cable PVC insulated aluminium conductor , served with inner sheathing of PVC Tape and overall PVc sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4 mm suspension wire , one twin core cable flat or circular of size 10 Sqmm complete all as specified and directed.
170
-
-
... More
S&F rigid non metallic PVC conduit medium grade 20 mm external dia ISI marked with accessories such as tees, bends,junctin boxes bell mouth tube ends including fixing accessories, locks as couplers lock nuts pipe hooks ets concealed in wallsceiling etccomplete all as specified and directed.
50
-
-
... More
S&F submain wiring with four runs of single core 6 sqmm PVC insulated unsheathed stranded copper frls conductor drawn in concealed conduit including 4 sqmm copper stranded conductor PVC insulated FRLS earth wire connected to main board complete all as specified and directed .(four number cable and one number earth wire shall be measured together as one length).