Military Engineer Services Tender

If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date21 May 2024
Closing Date19 Jun 2024
Tender Amount₹ 47,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Dismantling & Taking down of existing unsv batten/angle holder for replacement etc. complete all as specified and as directed.

450

-

-

... More
Dismantling & Taking down of existing unsv MCB, DBs,MCCB and Isolator for replacement etc. complete all as specified and as directed.

796

-

-

... More
M & L Point wiring with multistranded copper conductor single core, PVC insulated and unsheathed FRLSH cable , including PVC insulated unsheathed multi stranded copper conductor single core FRLSH cable as earth continuity conductor to common earth and connected to earth dolly with GI terminal boxes, modular frame & cover plate ( suitable for modular switch/sockets) for the following :-

-

-

-

... More
One light point controlled by one switch or one fan point controlled by one switch & fan regulator etc. with 1.5 Sqmm ( nominal area) cable & 1.5 Sqmm ( nominal area) cable as earth continuity conductor in existing concealed conduit complete all as specified and directed by Engr-in-charge

830

-

-

... More
Switch socket combination (multi purposes) 3 Pin 5 Amps point to be controlled by one switch & wiring with 2.5 Sqmm PVC insulated and unsheathed FRLSH copper conductor cable 2.5 Sqmm PVC insulated earth wire on independent board

300

-

-

... More
All as per item No. 8 , here-in-before but One socket outlet3 pin 15 Amp on the Independent board complete all as specified.

180

-

-

... More
One bell point controlled by one push button with 1.5 Sqmm ( nominal area) cable & 1.5 Sqmm ( nominal area) cable as earth continuity conductor in existing concealed conduit complete all as specified and as directed.

10

-

-

... More
One light point controlled by two way switch with 1.5 Sqmm ( nominal area) cable & 1.5 Sqmm ( nominal area) cable as earth continuity conductor in existing concealed conduit complete all as specified and directed by Engr-in-charge

10

-

-

... More
Note for srl item no. 6.00 to 6.06 : 1. Switches & sockets shall be measured & paid separately under respective item of Sch 'A' 2. GI box shall be fixed flush in position with cement mortar ( 1: 4 ) complete all as specified.

-

-

-

... More
S & F switch modular type single pole one way, 6 Amp one module, complete all as specified.

1130

-

-

... More
S & F switch modular type single pole one way,16 Amp one module, complete all as specified.

150

-

-

... More
S & F socket outlet modular type multipupose, 2/3 pin, single pole one way,6 Amp, two module, complete all as specified.

300

-

-

... More
S & F socket outlet modular type multipupose, 2/3 pin, single pole one way,6 / 16 Amp, two module, complete all as specified.

180

-

-

... More
S & F switch modular type single pole two way, 6 Amp one module, complete all as specified.

20

-

-

... More
S & F bell push switch modular type single pole one way, 6 Amp one module, complete all as specified and as directed.

10

-

-

... More
S & F Fan regulator modular type, 5 step, high speed, two module etc.complete all as specified and as directed.

150

-

-

... More
S & F call bell ding dong type AC 230 V etc. complete all as specified and as directed.

10

-

-

... More
S & F ceiling rose,3 terminal PVC/Polycarbonate, suitable for 230 V, AC, 50 Hz supply, complete all as specified.

650

-

-

... More
S & F in repair lamp holder PVC/ Polycarbonate type with back plate etc. complete all as specified and as directed.

200

-

-

... More
S & F wall mounted extruded Aluminium / polycarbonate integrated LED batten fixture with tube 1.2 m, 20 watt, 1.2 m 3000/6500K, efficiency not less than 90 lumens/ watt, exturded Aluminium / polycarbonate, PC diffuser and integrated in built driver complete including making connection complete all as specified.

450

-

-

... More
S & F in replacement of sheet metal enclosure double door 8 way SPN, 240 V, ISI marked complete with netural and earth link and 200 Amp rated bus bar complete made out of CRCA steel sheet Factory made including blanking plate for unused module complete all as specified and directed.

40

-

-

... More
all as per item No. 24 above but 04 way TPN , 415 Volt complete all as specified and directed.

16

-

-

... More
S & F in replacement of MCB 6-32 Amp , 240 Volt, single pole, 10 KA 'C' series complete all as specified.

500

-

-

... More
S & F in replacement of MCB 40-63 Amp , 240 Volt, SPN, 10 KA 'C' series complete all as specified.

180

-

-

... More
S & F MCB TPN 40 to 100 Amp, 415 Volts, 10 KA 'C' series complete all as specified

60

-

-

... More
S & F in replacement of sub main two single core PVC FRLSH copper conductor unsheathed wire multi stranded 6.0 Sqmm along with earth wire 6.0 Sqmm copper conductor single core wire connected by common earth in and including medium grade 25 mm size concealed conduit complete all as specified. ( Note :- Two length of 6.0 Sqmm cable and one length of 6.0 Sqmm earth cable alongwith PVC concealed conduit will be measured as one running length)

1150

-

-

... More
S & F in replacement of sub main two single core PVC FRLSH copper conductor unsheathed wire multi stranded 10.0 Sqmm along with earth wire 10.0 Sqmm copper conductor single core wire connected by common earth in and including medium grade 25 mm size concealed conduit complete all as specified. ( Note :- Two length of 10.0 Sqmm cable and one length of 10.0 Sqmm earth cable alongwith PVC concealed conduit will be measured as one running length)

300

-

-

... More
S & F in replacement single pole and neutral enclosure 240 V with a two pin and earth plug and socket complete with one double pole MCB 20 Amps complete all as specified and as directed.

60

-

-

... More
S & F in repair RCCB Earth Leakage Protection 230 Volts, 25 Amp, AC type double pole 30mA ISI marked complete all as specified and as directed.

20

-

-

... More
M & L earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6mm thick burried directly in ground earth pit not less than 2.25 mtr deep below normal ground level with top edge of the plate vertically to a depth of not less than 1.5 mtr below ground level connection to and including 4mm dia (8 SWG) GI earth wire from earth plate to main switch board including necessary GI bolts, nuts, check nuts, washers, thimble etc. to the extend 7.5 mtr as earth lead by means of GI bolts & nuts etc, connecting to LT panel wlith provision of charcoal and salt all as per electrical plate No 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (medium grade) excavation and earth work returning , filling, ramming and remove of soil to a distance not exc 50 mtr, make good to match with existing surface and testing on completion.

30

-

-

... More
M&L for Attend the complaint for checking and locating faults of light/power circuits and defective electrical light/ fan/ bell/ switche 5 Amps/switch 15 Amp/socket outlet 5 Amps and 15 Amps for continuous electric supply or broken neutral system, rectify the same, tightening of loose wire/circuit by using the same old wire or by using new wire up to 1.00 metre length and similar petty work complete all as specified and directed at site. Note :Switches,sockets,bell push,call bell, light fitting/ Fixture shall be measured and paid separately under respective item.

3000

-

-

... More
S & F in repair switch piano, flush type single pole one way 5 Amp complete all as specified and as directed.

750

-

-

... More
S & F in repair switch piano, flush type single pole two way 5 Amp complete all as specified and as directed.

20

-

-

... More
S & F in repair switch piano, flush type single pole one way 15 Amp complete all as specified and as directed.

500

-

-

... More
S & F in repair bell push 5/6 Amp 230 V, AC etc.complete all as specified and as directed.

10

-

-

... More
S & F in repair socket outlet 3 pin, 5 Amp flush type etc.complete all as specified and as directed.

500

-

-

... More
S & F in repair socket outlet 2 in 1, 3 pin, 5 and 15 Amp flush type etc.complete all as specified and as directed.

450

-

-

... More
S & F in repair switch socket combination 2 in 1, 3 pin 5 and 15 Amp flush type universal etc.complete all as specified and as directed.

50

-

-

... More
S & F in repair call bell ding dong type AC 230 V etc. complete all as specified and as directed.

10

-

-

... More
S & F in repair stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. complete all as specified and as directed.

350

-

-

... More
S & F in repair wall mounted extruded Aluminium / polycarbonate integrated LED batten fixture with tube 1.2 m, 20 watt, 1.2 m 3000/6500K, efficiency not less than 90 lumens/ watt, exturded Aluminium / polycarbonate, PC diffuser and integrated in built driver complete including making connection complete all as specified.

1750

-

-

... More
S & F in repair wall mounted extruded Aluminium / polycarbonate integrated LED batten fixture with tube 1.2 m, 25 watt, 1.2 m 3000/6500K, efficiency not less than 90 lumens/ watt, exturded Aluminium / polycarbonate, PC diffuser and integrated in built driver complete including making connection complete all as specified.

1750

-

-

... More
S & F in repair wall mounted LED batten fitting 10 ( ± 10%) watt 6500 K, 0.6m, efficiency not less than 90 lumens/ watt, exturded Aluminium / polycarbonate, PC diffuser and inbuilt driver complete including making connection complete all as specified and directed by Engr-in-charge.

250

-

-

... More
S & F in repair lamp holder PVC/ Polycarbonate type with back plate etc. complete all as specified and as directed.

450

-

-

... More
S & F in repair LED lamp 7 watt ( base B-22 ) 6500 K, not less than 90 lumen/watt efficiency complete all as specified and as directed.

2000

-

-

... More
S & F in repair LED street light ( bldg security light) 35 watt , 230 V,AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver , lamp bracket with impact and corrosion resistant complete with IP 65/66 protection including fixing with GI/MS bracket made out of suitable size of light grade tube up to 1.2 mtr length bent to shape with 02 sets of MS clamp made out of minimum 3 mm MS flat iron with suitable bolt and nuts complete with making connection complete all as specified and as directed.

75

-

-

... More
S & F in repair LED flood light fitting square shape 150 watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver , lamp, bracket with impact and corrosion resistant complete with IP 65/66 protection with suitable bolt and nuts, fixing at any hight up to 15m complete with making connection complete all as specified and directed.

25

-

-

... More
S & F LED downlighter/spot light fitting, recessed mounted, round shaped of ceiling cut outØ160mm, 12 watts efficancy not less than 90 lumen/watt, 6500K extruded Aluminium/ polycarbonate, PC diffuser, module and inbuilet driver complete including making connection complete all as specified and directed.

50

-

-

... More
S & F in repair LED landscape/bollard light fitting, round shaped of 0.6m pole size, 8/10 watts, efficiency not less than 90 lumen/watt extruded aluminium/ polycarbonate, IP 65, PC diffuser, module and inbuilt driver complete including making connection & fixing of pole base with nut and bolt to PCC pedestal/coping complete all as specified and directed

10

-

-

... More
S & F in repair LED panel light fitting, recessed mounted, square shaped of size (595x595x65)mm, 36(± 10 %) watts efficiency not less than 90 lumen/watt, extruded aluminium/ polycarbonate, PC diffuser, module and inbuilt driver complete including making connection, complete all as specified and directed.

150

-

-

... More
S & F in repair LED panel light fitting, surface mounted, square shaped of size (600x600x70)mm, 34(± 10 %) watts efficiency not less than 90 lumen/watt, extruded aluminium/ polycarbonate, PC diffuser, module and inbuilt driver complete including making connection, complete all as specified and directed.

50

-

-

... More
S & F in repair post top lantern LED type 20 watt, 230 V AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistance complete with driver and lamp complete all as specified and directed

20

-

-

... More
S & F in repair rigid non - metallic PVC conduit external dia 20 mm in size inclusive of all Tees, bends, elbow, reducers, junction boxes, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddels, pipe hooks etc. complete all as specified and as directed.

400

-

-

... More
S & F in repair Hylem sheet cover 3mm thick of size 5" x 5" complete with machine screws/washer with provision of slots for switches, sockets, fan regulators ( including refixing of all switches, sockets, fan regulator dismantled from existing sheets) etc. complete all as specified and as directed.

150

-

-

... More
S & F in repair Hylem sheet cover 3mm thick of size 8" x 5" complete with machine screws/washer with provision of slots for switches, sockets, fan regulators ( including refixing of all switches, sockets, fan regulator dismantled from existing sheets) etc. complete all as specified and as directed.

150

-

-

... More
S & F in repair Hylem sheet cover 3mm thick of size 11" x8" complete with machine screws/washer with provision of slots for switches, sockets, fan regulators ( including refixing of all switches, sockets, fan regulator dismantled from existing sheets) etc. complete all as specified and as directed.

150

-

-

... More
S & F in repair sunken box of size 4" x 4" with approved depth and thickness complete with earth dolly including making good the diturb surface CM ( 1:3 ) to match the existing complete all as specified and as directed.

150

-

-

... More
S & F in repair sunken box of size 7" x 4" with approved depth and thickness complete with earth dolly including making good the diturb surface CM ( 1:3 ) to match the existing complete all as specified and as directed.

100

-

-

... More
S & F in repair sunken box of size 10" x 7" with approved depth and thickness complete with earth dolly including making good the diturb surface CM ( 1:3 ) to match the existing complete all as specified and as directed.

70

-

-

... More
M & L in replacement for earthing circuit wiring ( green colour) with multistranded copper conductor , single core FRLS, PVC insulated and unsheathed cable of size 1.5 Sqmm, run through existing conduit connected to existing terminal/ socket point outlet / MCBs etc. complete all as specified and as directed. Note :- One run of cable in existing concealed conduits/surface drawn with suitable saddling shall be measured as one running meter ( RM) and shall deemed to be included in the quoted rate.

130

-

-

... More
M & L in replacement for earthing circuit wiring ( green colour) with multistranded copper conductor , single core FRLS, PVC insulated and unsheathed cable of size 2.5 Sqmm, run through existing conduit connected to existing terminal/ socket point outlet / MCBs etc. complete all as specified and as directed. Note :- One run of cable in existing concealed conduits/surface drawn with suitable saddling shall be measured as one running meter ( RM) and shall deemed to be included in the quoted rate.

130

-

-

... More
M & L in replacement for earthing circuit wiring ( green colour) with multistranded copper conductor , single core FRLS, PVC insulated and unsheathed cable of size 6.0 Sqmm, run through existing conduit connected to existing terminal/ socket point outlet / MCBs etc. complete all as specified and as directed. Note :- One run of cable in existing concealed conduits/surface drawn with suitable saddling shall be measured as one running meter ( RM) and shall deemed to be included in the quoted rate.

180

-

-

... More
S & F in repair MCCB 415 V, FP 63 Amp 16 KA, complete all as specified and directed by Engr-in-charge.

12

-

-

... More
S & F in repair PVC junction boxes ( 1 x 4 way) complete all as specified and directed

100

-

-

... More
Note:- Net contract sum shall be calculated after deduction of Sch of credit.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.