Military Engineer Services Tender

... More
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date5 Sep 2024
Closing Date28 Sep 2024
Tender Amount₹ 12,40,941 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply only refrigerant gas R-134a, complete all as specified and directed by Engineer in Charge. Make for Srl No1 to 4 Mefron/Fluron/Freon

10

-

-

... More
Supply and fix in replacement of existing unserviceable outdoor unit of split typw AC of 1.5 TR , min 5 star rating, 4in 1 invertor type capacity with compressor , copper condensor coil, fan motor etc complete all as specified and directed by Engineer in Charge.

1

-

-

... More
Supply and fix in replacement of existing unserviceable outdoor unit of split typw AC of 2.0 TR , min 5 star rating, 4in 1invertor type capacity with compressor , copper condensor coil, fan motor complete etc complete all as specified and directed by Engineer in Charge.

1

-

-

... More
S & F in repairs Starting Relay of for 2.0/1.5 Ton capacity Window/Split type AC's complete all as specified and directed by Engineer in Charge.

4

-

-

... More
S & F in repairs Overload protector SR 1622 for Window/Split type AC's, complete all as specified and directed by Engineer in Charge.

4

-

-

... More
S & F in repairs Starting capacitor of 80 to 100 MFD for Window/Split type AC's complete all as specified and directed by Engineer in Charge.

4

-

-

... More
S & F in repairs Starting capacitor of 100 to 120 MFD for Window/Split type AC's complete all as specified and directed by Engineer in Charge.

4

-

-

... More
S & F in repairs Running capacitor of 36 MFD for Window/Split type AC's complete all as specified and directed by Engineer in Charge.

4

-

-

... More
S & F in repairs dual Running capacitor of 50/6 MFD for Window/Split type AC's complete all as specified and directed by Engineer in Charge.

60

-

-

... More
S&F in repairs Thermostatic switch/Thermistor for Window/Split type AC's complete all as specified and directed by Engineer in Charge.

4

-

-

... More
S&F in repairs Selector switch of rotary type for Window/Split type AC's acomplete all as specified and directed by Engineer in Charge.

2

-

-

... More
S&F in repairs in replacement of double shaft/ Single shaft or as per site requirement Blower fan motor suitable for 1.5/2.0 Ton capacity Split /Window AC's complete all as specified and directed by Engineer in Charge.

2

-

-

... More
S&F in repairs of Fan blade for 1.5/2 Ton capacity Window / Split type AC as per existing make and model complete all as specified and directed by Engineer in Charge.

2

-

-

... More
S&F in repair of Air filter for window/split type AC 1.5/2 Ton as per existing make and model complete all as specified and directed by Engineer in Charge.

10

-

-

... More
S&F in repair of Front grill for window type AC as existing make and model, complete all as specified and directed by Engineer in Charge.

10

-

-

... More
Taking down carefully old burnt/unserviceable rotary compressor unit of 1.5 ton capacity and replacing the same with new rotary compressor (i.e as per site requirenment) including necessary accessories i e capillary tube including strainer and mounting materials,etc, welding, brazing, leak testing, vaccumissing and charging the refrigerant gas to the required pressure and weight, reinstalling the AC unit on the same place including testing and commissioning complete to any make of AC complete all as specified and directed by Engineer in Charge.

6

-

-

... More
All as per Item No-19 here-in-before but of 2.0 Ton capacity reciprocation compressor complete all as specified and directed by Engineer in Charge.

1

-

-

... More
All as per Item No-19 here-in-before but of 3.0 Ton reciprocation compressor complete all as specified and directed by Engineer in Charge.

1

-

-

... More
Cleaning the unit with CTC except evaporator and condensor and leak testing the system with CO2 gas and detecting the leak with Nitrogen gas and repairing, brazing and sealing the leakage by replacing Suction/delivery valve which ever is required on site with and including flare nuts complete including charging the existing refrigerant gas to the required pressure and weight of gas for 1.5 Ton capacity window/split type AC of any make complete all as specified and directed by Engineer in Charge.

15

-

-

... More
All as per Item No-22 here-in-before but of 2.0(Multi unit)/3.0 Ton capacity window/split type AC, complete all as specified and directed by Engineer in charge. Note for item No 22 & 23 :- Gas charging will be measured against relevant item of this schedule.

3

-

-

... More
Servicing and overhauling the 1.5/2.0 Ton capacity (Window/Split) AC with water, chemical air clearner, filter and drying, checking the bolt and nut connections, filling, refixing /shifting/electrical loose replacement of minor items required to make it fully functional ,connections and testing ccomplete all as specified and directed by Engineer in charge.

40

-

-

... More
S & F in replacement of exisitng unserviceable/ leakage evaporating coil made out of 25 SWG copper tubing having 30/34G aluminium fins per length of existing size for window of any type/make AC's of 1.5/2.0 Ton capacity including taking out the Unsv evaporating coil complete all as specified and directed by Engineer in charge.

2

-

-

... More
S & F in replacement of exisitng unserviceable/ leakage condensor coil made out of 25 SWG copper tubing having 30/34G aluminium fins per CM length of existig size for window any type AC's of 1.5/2.0 Ton capacity indlcuding taking out the Unsv condensor coil complete all as specified and directed by Engineer in charge.

3

-

-

... More
S&F Indoor unit of Split type AC of 1.5 TR 4in 1 inverter type, minimum 5 star rating capacity suitable to existing Outdoor Unit including the necessary connections and testing complete all as specified and directed by Engineer in charge.

1

-

-

... More
All as per Item No-27 above but for Split AC 2.0 TR capacity complete all as specified and directed by Engineer in charge.

1

-

-

... More
Dismantling the water cooler/Refrigerator /Deep freezer and repairing the body by welding, brazing, riveting where required and making good of stand and bottom portion painting the body on external surfaces with one coat of synthetic paint over a coat of primer of same colour by machine spray and reassembling and installing in original position and testing complete all as specified and directed by Engineer in charge.

2

-

-

... More
Cleaning all the parts Water cooler/Refrigeratos/Deep Freezer, condensor unit and capillary tubes and checkng the leakage of gas with CO2 and brazing, rectifying the leakge, including charging the refrigerant gas to required pressure and weight fixing back to the original positon, testing comissioning complete for any make and any capacity of water cooler complete all as specified and directed by Engineer in charge.

2

-

-

... More
S&F in repairs Relay Assembly for any capacity Water Coolers/Refrigerators/Deep Freezer of any make complete all as specified and directed by Engineer in charge.

2

-

-

... More
S & F in repairs Thermostatic Switch for any capacity Water Coolers/Refrigerators/Deep Freezer of any make complete all as specified and directed by Engineer in charge.

2

-

-

... More
S & F in repairs copper wounded condenser fan Motor Single phase, 230V for any capacity Water Coolers of any make complete all as specified and directed by Engineer in charge.

2

-

-

... More
S & F in repairs Fan motor blade of existing size and model for any capacity Water Coolers of any make complete all as specified and directed by Engineer in charge.

2

-

-

... More
S & F in repairs Float valve 15 MM bore with brass spindle and PVC ball complete fof water cooler and PVC tanks Coolers of any make complete all as specified and directed by Engineer in charge.

2

-

-

... More
S & F in repairs Push/lift tap 15 mm bore chromium plated forany capacity Water Coolers of any make complete all as specified and directed by Engineer in charge.

2

-

-

... More
S&F in repairs Overload protector 1022/522, for any capacity Water Coolers/Refrigeratos/Deepfreezer of any make complete all as specified and directed by Engineer in charge.

2

-

-

... More
S&F in repairs Starting/running Capacitor of suitable capacity for Water Coolers/Refrigeratos/Deep Freezer of any make complete all as specified and directed by Engineer in charge.

4

-

-

... More
Removing of defective condenser fan motor from water cooler/Deep Freezer rewinding of fan motor with same gauge and turns and weight of copper enameled wire and replacement of bearing and refixing, testing and commissioning of water coolers of any make complete all as specified and directed by Engineer in charge.

2

-

-

... More
S&F in replacement of LED digital type AC timer for cycle operation of 02 any type /capacity of AC with displaying AC1/AC2 on indication & 1 to 24 Hrs programmable to take load upto 03 ton window /spilt Ac with Auto/ Manual facility at site complete all as specified and directed by Engineer in charge.

1

-

-

... More
Taking out old burnt/unserviceable compressor unit of water cooler/Refrigerators/deep freezer and replacing the same with new compressor of existing unit including necessary nuts, bolts, mounting materials, welding, brazing, leak testing and charging the refrigerant gas, R-22 to the required pressure and weight, reinstalling in the same place including servicing, testing and commissioning complete to any make of water cooler 40/80 Ltrs /Refrigerator/deep freezer of any Capacity complete all as specified and directed by Engineer in charge.

2

-

-

... More
Taking out old burnt/unserviceable compressor unit of water cooler and repalcing the same with new compressor of existing unit including necessary nuts, bolts, mounting materials, welding, brazing, leak testing and charging the refrigerant gas, R-22 to the required pressure and weight, reinstalling in the same place including servicing, testing and commissioning complete to any make of water cooler 60/120,150/150 Litre Capacity water cooler complete all as specified and directed by Engineer in charge.

2

-

-

... More
S & F in drain tray and PVC flexible pipe and connecting to inlet pipe for any capacity of water cooler, including holding clamps complete all as specified and directed by Engineer in charge.

3

-

-

... More
Servicing the water cooler/desert cooler of any make including cleaning the water tank, and the side body by washing, rubbing down including removing all the dust, dirt complete all as specified and directed by Engineer in charge.

30

-

-

... More
S & F in repairs submersiable water pump motor as per existing capacity complete for desert coolers of any make complete all as specified and directed by Engineer in charge.

40

-

-

... More
S&F in replacement Renewal of Fan motor with new fan blade complete of desert cooler single phase, 215 Volts, AC, 50 Hz complete for desert coolers of any make complete for capacity 3000/4000 CUM, complete all as specified and directed by Engineer in charge.

25

-

-

... More
S & F in repairs Fan blade of desert cooler Metallic/PVC as per existing model complete for desert coolers of any make complete for capacity 3000/4000 CUM, complete all as specified and directed by Engineer in charge.

15

-

-

... More
S & F in repairs KHAS-KHAS grass (One set of three) as approved by Engr-in-charge, complete for desert coolers of any make complete for capacity 3000/4000 CUM. complete all as specified and directed by Engineer in charge.

60

-

-

... More
S & F in repairs PVC water tube and distribution with 3 way PVC connection,PVC bends assembly complete, for desert coolers of any make, complete all as specified and directed by Engineer in charge.

60

-

-

... More
S & F in repairs Caster wheels (Set of Four) complete, for desert coolers of any make complete for capacity 3000/4000 CUM, complete all as specified and directed by Engineer in charge.

4

-

-

... More
S&F in repairs front grill of desert cooler of capacity 3000/4000 Cum of any make complete all as specified and directed by Engineer in charge.

8

-

-

... More
S&F in repairs switch assembly for desert coolers of capacity 3000/4000 Cum of any make complete all as specified and directed by Engineer in charge.

12

-

-

... More
S&F in repairs Capacitor of 4/5 MFD capacity suitable for fan motor of desert coolers of capacity 3000/4000 CFM of any make complete all as specified and directed by Engineer in charge.

40

-

-

... More
M&L for wiring to desert coolers with PVC insulated multistranded, copper conductor single core of size 1.5 Sqmm including PVC clamps, brackets as required and connection, water pump, control switches including taking down old wiring complete all as specified and directed by Engineer in charge.

20

-

-

... More
Supply and fix in repairs connection wire of 3 core copper wire PVC insulated of size 4 Sqmm for any capacity window type/Split type AC, water coolers/desert coolers complete all as specified and directed by Engineer in charge.

90

-

-

... More
S&F in repairs plug top 3 pin 5 Amps for desert cooler/water coolers/refrigerator complete all as specified and directed by Engineer in charge.

40

-

-

... More
S&F in repairs 3 pin industrial plug top with socket suitable for industrial metal clad socket, single phase, 230 Volts, AC including reconnecting complete all as specified and directed by Engineer in charge.

30

-

-

... More
S&F in repairs copper tube of size 3/8" / 5/8" dia includng necessary soldering, flaring and connecting and testing in between indoor to out door units of split type AC 1.5 Ton complete all as specified and directed by Engineer in charge.

25

-

-

... More
All as per Item No 58 here-in-before but size of copper tubing 1/2" / 1/4" dia complete all as specified and directed by Engineer in charge.

25

-

-

... More
S&F in repairs nitrile rubber insulation pipeswith suitble size sellotap for suction (discharge pipe) felt for split type AC 1.5 / 2.0/3.0 Ton copper tube as in inlet/outlet to out door unit complete all as specified and directed by Engineer in charge.

70

-

-

... More
S&F in repairs remote control assembly set suitable for split type AC 1.5 / 2.0/3.0 Ton capacity of any make, complete all as specified and directed by Engineer in charge.

5

-

-

... More
S&F in repairs indoor blower motor for split type AC as per existing model, sample complete all as specified and directed by Engineer in charge.

5

-

-

... More
Taking down carefully existing serviceable split type AC unit of 1.5/2.0 TR capacity and shiftting to in another location and refixing in any position and height complete with all connected work like making holes, fixing mounting brackets and all other required accessories including making good the distrubed surfaces complete all as specified and directed by Engineer in charge. Note :- Quoted rates deemed to included necessory core cutting on walls reqd no of fushners to fix the bracket on wall

4

-

-

... More
S&F in repairs capillary tube including strainer suitable for split type AC 1.5/2.0 TR capacity with necessary brazing, leak testing complete all as specified and directed by Engineer in charge.

5

-

-

... More
S&F in repairs voltage stabilizer single phase, 230 Volts, AC, 50 Hz of capacity 4 KVA wall mounting type window type AC with low and high cut off and intelligent delay input voltage 160 Volts to 260 Volts complete all as specified and directed by Engineer in charge.

7

-

-

... More
All as per Item No-65 here-in-before but 5 KVA capacity voltage stabilizer complete all as specified and directed by Engineer in charge. Make for Item Nos. 65 & 66 MAke :- 'V' GUARD/ BLUEBIRD/Skyline

7

-

-

... More
Repair to stabilizer of 4KVA/5KVA capacity of Transformer including spares partsas required functional testing & reinstallaing after necessary repairs complete all as specified and directed by Engineer in charge.

15

-

-

... More
Taking out unserviceable 1 Pole contactor from the split type AC and replacing the same as existing with new contactor suitable for 240V, 50Hz coil complete all as specified and directed by Engineer in charge.

2

-

-

... More
S&F in repairs 2 Pole contactor from the split type AC and replacing the same with new contactor suitable for 240V, 50Hz coil complete all as specified and directed by Engineer in charge.

2

-

-

... More
S&F in repairs drain pipe /Drain Pan from AC units of any type and any capacity complete all as specified and directed by Engineer in charge.

25

-

-

... More
S&F Brass Valves (set of 2 Nos)/ Expansion valve suitable for split type AC/ Window AC of capacity 1.5/2TR/3 TR as per existing type including necessary brazing and sealing the leakage, Leak testing , charging the Refrigerant gas up to required pressure including taking down the unserviceable brass valves complete all as specified and directed by Engineer in charge. Note :- Gas charging will be measured and paid under relevant item of this schedule.

1

-

-

... More
S&F in repairs copper cable of size 3 core 2.5 Sqmm, PVC insulated sheathed, multistranded copper conductor complete all as specified and directed by Engineer in charge.

45

-

-

... More
Material and Labour for sub main wiring with 2 runs of 4 Sqmm single core PVC insulated unsheathed FRLS cable 1100 Volts grade multistranded with copper conductor drawn through and including non metallic rigid PVC conduit ISI marked 25 mm dia including conduit accessories concealed/surface type on walls, roof, floors etc including one run of 4.0 Sqmm PVC copper conductor as earth continuity wire including taking down unserviceable sub main wiring including conduit complete all as specified and directed by Engineer in charge. Note : 2 Runs of 4 sqmm cable 1 run of 4 sqmm cable and 1 run of PVC conduit shall be measured as one unit for the purpose of payment.

45

-

-

... More
All as per srl item No.73 here-in-before but with 2 runs 6 sqmm including 1 run of 6 sqmm PVC copper conductor FRLS cable as earth continuity wire in not less than 25mm dia PVC conduit, complete all as specified and directed by Engineer in charge. Note : 2 Runs of 6 sqmm cable 1 run of 6 sqmm cable and 1 run of PVC conduit shall measured as one unit for the purpose of payment.

30

-

-

... More
S&F in repairs non metallic PVC conduit 20 mm dia inclusive of boxes tees, bends, elbows, reducers, tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed by Engineer in charge.

75

-

-

... More
S&F in repairs metallic AC earth plug and socket with sheet metal enclosure with MCB SP 20A to 32 A complete all as specified and directed by Engineer in charge.

10

-

-

... More
Supply only capacitor 2.5 mfd suitable for ceiling fan and testing complete all as specified and directed by Engineer in charge.

50

-

-

... More
Taking down unserviceable desert cooler and supply, installation, testing, commissioning of New desert cooler of capacity 4500 Cum per hour made out of 01 mm thick galvanised steel sheet with complete fully exhaust fan 450 mm sweep, 1400 rpm motor and suitable capacity submersible pump and wood wool fitted in frame made from 25x25x3 mm angle iron and 25x25 mm size MS wire mesh net of 14swg dia fitted on both sides for supporting wood wool including suitable size top and bottom water tray made of 1.00 mm GI sheet 1000 watts speed control electronic regulator, suitbale size connection cable 3 core with copper conductor with moulded plug top, fan blade and all fixing accessories complete all as specified and directed by Engineer in charge. Note : All Electrical Equipments shall be of BSI/ ISI Marks.

6

-

-

... More
M&L for Taking down,repair of existing unserviceable of PCB of window/ spilt AC of 1.5/2.0/3.0 TR by replaceing its unsv parts make it fully functional and refixing the same on existing location complete all as specified and directed by Engineer in charge.

8

-

-

... More
M&L for Taking down,repair of existing unserviceable of PCB of invertor spilt AC of 1.5/2.0/3.0 TR by replaceing its unsv parts make it fully functional and refixing the same on existing location complete all as specified and directed by Engineer in charge.

2

-

-

... More
S & F in repalcement of existing unserviceable/burnt with New PCB of window/spilt AC of 1.5/2.0/3.0 TR of same make by replaceing its unsv parts make it fully functional and refixing the same on existing location complete all as specified and directed by Engineer in charge.

3

-

-

... More
S & F in repalcement of existing unserviceable/burnt with New PCB of invertor type spilt AC of 1.5/2.0/3.0 TR of same make by replaceing its unsv parts make it fully functional and refixing the same on existing location complete all as specified and directed by Engineer in charge.

2

-

-

... More
Supply and fix in replacement of existing unserviceable outdoor unit of split type AC of 1.5 TR ,with new one existing capacity and make with compressor , copper condensor coil, fan motor complete etc complete all as specified and directed by Engineer in charge.

1

-

-

... More
Supply and fix in replacement of existing unserviceable outdoor unit of split type AC of 2.0 TR ,with new one existing capacity and make with compressor , copper condensor coil, fan motor complete etc complete all as specified and directed by Engineer in charge.

1

-

-

... More
S & F in replacment Indoor unit of Split type AC of 1.5 TR with existing capacity and make capacity suitable to existing Outdoor Unit including the necessary connections and testing complete all as specified and directed by Engineer in charge.

1

-

-

... More
All as per Item No-85 above but for Split AC 2.0 TR capacity complete all as specified and directed by Engineer in charge.

1

-

-

... More
Supply only capacitor 3.5/ 4.0 mfd suitable for Exhaust fan/Wall mounted fan/Air Circulator Fan, complete all as specified and directed by Engineer in charge.

50

-

-

... More
Taking down carefully of any type point wiring light fans socket or power complete fitting such as switch ceiling roses, pendent, regulator, sockets etc removing material and making good disturb surface of wall floor etc complete all as specified and directed by Engineer in charge.

98

-

-

... More
Material and labour for point wiring complete with ISI marked 1.5 Sqmm PVC insulated multistranded single core cable with copper conductor (FRLS) 1100 volts grade drawn through and including PVC rigid conduit 20 mm or higher dia ISI marked as required at site including conduit accessories such as Junction Boxes, Inspection Covers etc, concealed/surface type on stone/brick masonry walls, roofs, floors etc by means of saddles and clamps etc including PVC gang boxes as required at site for concealed/surface conduit wiring and modular plates & covers as required at site for housing switches sockets, regulators etc. including providing of 1.5 Sqmm PVC insulated multistranded unsheathed FRLS copper conductor as earth continuity conductor and connecting to common earth dolly all as specified for and connecting up complete for the following:- One light point controlled by one, one way switch

40

-

-

... More
All as per srl Item No. 89 here-in-before but for One ceiling fan/exhaust fan point controlled by one way switch 6 Amps.

10

-

-

... More
All as per srl Item No. 89 here-in-before but for one bell point controlled by one bell push 6 amps.

5

-

-

... More
All as per srl Item No. 89 here-in-before but for Switch Socket outlet 2/3 pins 6 Amps on independent board.

20

-

-

... More
All as per srl Item No. 89 here-in-before but for Switch Socket outlet 2/3 pins 6 Amps on same board.

8

-

-

... More
Material and labour for point wiring complete with ISI marked 4 Sqmm PVC insulated unsheathed multistranded single core cable with copper conductor (FRLS) 1100 volts grade drawn through and including PVC rigid conduit 20 mm or higher dia ISI marked as required at site including conduit accessories such as Junction Boxes, Inspection Covers etc, concealed/surface type on stone/brick masonry walls, roofs, floors etc by means of saddles and clamps etc including PVC gang boxes as required at site for concealed/surface conduit wiring and modular plates & covers as required at site for housing switches sockets, regulators etc. including providing of 4 Sqmm PVC insulated multistranded unsheathed FRLS copper conductor as earth continuity conductor and connecting to common earth dolly for 15Amps all as specified including taking down old point wiring complete as directed.

15

-

-

... More
S&F in repairs switch piano one way 5 Amps 240 Volt complete all as specified and directed by Engineer in charge.

25

-

-

... More
S&F in repairs switch socket outlet 3 pin,5 Amps 240 Volt complete all as specified and directed by Engineer in charge.

25

-

-

... More
S&F in repairs switch socket combination 5 pin 15 Amps multipurpose type complete all as specified and directed by Engineer in charge.

25

-

-

... More
S&F in repairs Bell push flush type 5 Amps complete all as specified and directed by Engineer in charge.

20

-

-

... More
S&F in repairs lamp holder angle/ batten type complete all as specified and directed by Engineer in charge.

10

-

-

... More
S&F in repairs fan regulator 240 V AC electronic step type complete all as specified and directed by Engineer in charge.

30

-

-

... More
S&F in repairs modular fan regulator 120watt 240 V AC two module type complete all as specified and directed by Engineer in charge.

30

-

-

... More
S&F in replacement for ceiling rose, 3 terminals /PVC/Polycarbonate, isolated body, complete all as specified and directed by Engineer in charge.

60

-

-

... More
S&F in repairs modular Socket 6A-2/3 pin combined two module type complete all as specified and directed by Engineer in charge.

30

-

-

... More
S&F in repairs modular Socket 6A/16A-2/3 pin combined two module type complete all as specified and directed by Engineer in charge.

30

-

-

... More
S&F in repairs modular 1 way 6Amp switch 1 module complete all as specified and directed by Engineer in charge.

40

-

-

... More
S&F in repairs 1 way 15 Amp switch 1 module complete all as specified and directed by Engineer in charge.

30

-

-

... More
S&F in repairs Piano switch 2 way 15 amps1 module complete all as specified and directed by Engineer in charge.

30

-

-

... More
S&F in repairs bell ding dong, AC, 230V, single pole complete all as specified and directed by Engineer in charge.

25

-

-

... More
S&F led luminaire 600 mm x 600 mm 35/36 watt, 220V AC recessed type with high efficiency PMMA diffuser soft glare light with LED efficacy of 120 lm/watt electronic driver,suitable for roof ceiling including connecting up with driver three core copper conductor 1.5 sqmm size complete all as specified and directed by Engineer in charge.

30

-

-

... More
S&F in repairs post top lantern LED type 20 watt 230 watts volts AC outdoor type with decorative post top for 360 degree indirect light IP65 protection with impact and corrosion resistant complete with driver and lamp along with necessary wiring,accessroies complete all as specified and directed by Engineer in charge.

6

-

-

... More
S&F in replacment LED polycarbonate tube rod retrofit 18Watt, 6500K CCT,proffesional luminaries single side connection with 10% THD complete all as specified and directed by Engineer in charge.

60

-

-

... More
S&F in replacment LED polycarbonate tube rod 22Watt, 6500K CCT,proffesional luminaries single side connection with 10% THD complete all as specified and directed by Engineer in charge.

55

-

-

... More
S&F in replacment indoor industrial type surface/wall mounted LED integral batten 20 W, 6500K CCT, alluminium extruded body and polycarbonate diffuser, 10%THD, integral elctronic driver complete fixing with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete removing unserviceable fittings complete all as specified and directed by Engineer in charge.

88

-

-

... More
S&F in replacment indoor industrial type surface/wall mounted LED integral batten 10W, 6500K CCT, alluminium extruded body and polycarbonate diffuser, 10%THD, integral elctronic driver complete fixing with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete removing unserviceable fittings complete all as specified and directed by Engineer in charge.

20

-

-

... More
Dismantling and taking down Geyser of 25/50 litres capacity of any make and pattern from the existing position and removing bolts and nuts, opening and taking out all internal unserviceable parts, leak testing of the inner container, refixing the same in original position after necessary repairs complete all as directed. Note:- Replacement of unserviceable parts will be measured and paid separately under relevant items of this BOQ.

30

-

-

... More
S&F in repairs geyser element of any type and model for 25/50 litres capacity for the 1500 W ISI marked complete all as specified and directed by Engineer in charge.

30

-

-

... More
S&F in repairs thermostat of the geyser, 15 Amps and temperature of 70º C complete all as specified and directed by Engineer in charge.

15

-

-

... More
S&F in repairs PVC connection with metal fabricated outer connection for geyser, of best quality 15mm dia, 600mm long with union, brass nuts and washers for hot water pipe for outlet connection complete all as specified and directed by Engineer in charge.

30

-

-

... More
S&F in repairs copper cable of size 3 core 2.5 Sqmm, PVC insulated sheathed, multistranded copper conductor complete all as specified and directed by Engineer in charge.

50

-

-

... More
Supply and fix in replacement MCB DB 12 way SPN (double door) sheet metal enclosure factory made suitable for MCB DB's 240 volts with 200 amp rated busbar, neutral & earthing link bar, flush/surface mounting complete including taking down the existing DB of any type & size by removing from existing circuits and refixing the new DBs and circuits complete all as specified and directed by Engineer in charge.

2

-

-

... More
Supply and fix in replacement MCB DB 08 way SPN (double door) sheet metal enclosure factory made suitable for MCB DB's 240 volts with 200 amp rated busbar, neutral & earthing link bar, flush/surface mounting complete including taking down the existing DB of any type & size by removing from existing circuits and refixing the new DBs and circuits complete all as specified and directed by Engineer in charge.

8

-

-

... More
Supply and fix in replacement MCB TPN DB 04 way (double door) sheet metal enclosure factory made suitable for MCB TPN incomer and MCBs as outgoing with 200 amp rated busbar, neutral & earthing link bar, flush/surface mounting complete including taking down the existing DB of any type & size by removing from existing circuits and refixing the new DBs and circuits complete all as specified and directed by Engineer in charge.

2

-

-

... More
Supply and fix in replacement of MCB single pole 6-32 Amps working on 240 volts, 50 HZ AC, 10 KA 'C' curve all complete all as specified and directed by Engineer in charge.

50

-

-

... More
S&F in replacement of MCB SPN 32-40 Amps working on 240 volts, 50 HZ AC, 10 KA 'C' curve complete all as specified and directed by Engineer in charge.

20

-

-

... More
Supply & fixing of MCB TP 40 Amps complete 415 V 50 Hz,10 KA 'C' curve including taking down old un serviceable isolators complete all as specified and directed by Engineer in charge.

10

-

-

... More
Supply & fixing of MCB 4 pole operating on 415V, AC supply of capacity 63-100 Amps ,10 KA 'C' curve including taking down old existing un serviceable isolators complete all as specified and directed by Engineer in charge.

10

-

-

... More
S&F in repairs metallic AC earth plug and socket with sheet metal enclosure with MCB SP 20A complete all as specified and directed by Engineer in charge.

15

-

-

... More
S&F MCCB 100 Amps, 3/4 pole, 16KA, 415 Volts, 50 HZ, Icu=100%Ics thermal magnetic fixed olc and short circuit rating including necessary fixing arrangement for fixing of MCCB to the existing panel, connecting cable connections including taking down old unserviceable MCCB complete all as specified and directed by Engineer in charge.

2

-

-

... More
Taking down ceiling fan/exhaust fan/ wall mounted fan / Air circulator fan of any sweep for servicing / repairing / maintenance, opening up, identifying and replacing the defective parts, cleaning, greasing,etc, reassembling and hanging up/fixing back at its original position, connecting up and testing complete all as specified and directed by Engineer in charge. Note : Cost of spares such as capacitors, bearings, Shaft etc will be measured and paid for separately under respective Item of sch A as supply only.

230

-

-

... More
Supply only capacitor 2.5/4 mfd suitable for ceiling fan and testing complete all as specified and directed by Engineer in charge.

230

-

-

... More
M&L for replacement of Outer body and 25 ltrs capacity inner copper tank with and including copper Geyser geyser assy of of suitable size with nuts , bolts , gasket indiactors lamps complete all as specified and directed by Engineer in charge.

10

-

-

... More
Disconnecting electric connection and taking down carefully fan of any type and size/sweep as described below, removing the burnt winding of fan motor and cleaning the stator completly removing the burnt sludges from the slots and rewinding with super enameled copper winding wire of suitable gauge or of matching size to the exisiting wires with same turns ratio including all insulating material such as insulation paper sleeve, tape, varnishing etc and reassembling, testing, transporting back to site and refixing to original position complete all as specified and directed by Engineer in charge. Note:- The contractor should assemble the rewinded stator core only after submitted the sample rewinded core for approval.

-

-

-

... More
All as per Item No 132 for Celling fan of size 1200/1400mm sweep.

120

-

-

... More
All as per Item No 132 for Wall mounted/Pedstal fans size 350/450 mm sweep Oscillating.

20

-

-

... More
All as per Item No 132 for Exhaust fan of 350/450 mm sweep.

30

-

-

... More
Supply only bearing No.6201/6202/6203/6204 or any other No matching to the existing size and suitable for ceiling fan/exhaust fan/wall mounted fan.

100

-

-

... More
Preparation of old surface of exhaust fan of any sweep by removing old paint using paint remover or by burning off using blow lamp and cleaning with cloth and Spray painting complete exhaust fan with superior quality synthetic enamel paint (Smoke grey) after applying a single coat of primer complete all as specified and directed by Engineer in charge.

50

-

-

... More
All as per serial item no 137 above but Ceiling fan of size 1200/1400 mm sweep with superior quality enamel paint ( Half White) complete all as specified and directed by Engineer in charge.

280

-

-

... More
S&F PVC rectangular block for mounting, switches, sockets,PVC rectangular block for mounting, switches, sockets,fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 100 mm x 100 mm and 50 mm deep fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 100 mm x 100 mm and 50 mm deepold unserviceable sheet complete all as specified and directed by Engineer in Charge.

20

-

-

... More
All as per srl item No. 139 here-in-before but of 175mm x 100mm size complete all as specified and directed by Engineer in Charge.

17

-

-

... More
All as per srl item No.139 here-in-before but of 250mm x 300 mm size complete all as specified and directed by Engineer in Charge.

16

-

-

... More
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated atandard aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections, one twin core cable of size 6 sqmm flat or circular complete all as specified and directed by Engineer in Charge.

90

-

-

... More
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6.3mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0 mm dia of minimum 15m length by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 in SSR PART-I connected to earthing test point all as specified or indicated including provision of earthing lead protection pipe, PCC earth pit with cover, excavation & earth work, testing on completion etc complete all as specified and directed by Engr-in-Charge.

3

-

-

... More
All as per item no 143 but using galvanised iron strip 25x4mm as earthing lead complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
S&Fix/lay GI earth wire 4 mm dia on walls/floor as earth continuity conductor connected to DBs/ panels etc. complete all as specified and directed by Engr-in-Charge.

51

-

-

... More
Ditto- but as per item no 145 but using galvanised iron strip 25x4mm, complete all as specified and directed by Engr-in-Charge.

50

-

-

... More
Supply and Fix GI tubing 15mm dia light grade for protection of GI earth wire complete all as specified and directed by Engr-in-Charge.

50

-

-

... More
Supply and fix in replacement SS geyser assembly as per existing size/shape it may be 6hole/9hole or without to make the geyser fully funtional complete all as specified and directed by Engr-in-Charge.

18

-

-

... More
Supply and fix in replacement MCB DB 04 way SPN (double door) sheet metal enclosure factory made suitable for MCB DB's 240 volts with 200 amp rated busbar, neutral & earthing link bar, flush/surface mounting complete including taking down the existing DB of any type & size by removing from existing circuits and refixing the new DBs and circuits complete as reqd at site as directed by Engineer in Charge.

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.