Military Engineer Services Tender
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Costs
EMD
₹ 1,11,700Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_693342_1Tender No
CWE/P-55/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
M&L for reinforced cement concrete M-25 (Design Mix) Type B1 1:2:4 using 20 mm graded aggregate in columns, pillars, piers, posts and struts, complete all as specified and directed.
5.3
-
-
... More
M&L for reinforced cement concrete M-25 (Design Mix) Type B1 1:2:4 using 20 mm graded aggregate in slabs supported on walls,beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and directed.
3.3
-
-
... More
M&L for reinforced cement concreteM-25 (Design Mix)Type B1 1:2:4 using 20 mm graded aggregate in beams, cantilevers, shelves, bressummers,chajjas, lintels over 1.5m span, complete all as specified and directed.
2.25
-
-
... More
Use and waste Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter - Rough finished surfaces of concrete - Flat, complete all as specified and directed.
42
-
-
... More
Use and waste formwork to sides of pillars, posts, struts, piers, columns and stanchions - Rough finished surfaces of concrete - Square, rectangular or polygonal, complete all as specified and directed.
51
-
-
... More
Use and waste Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) - Rough finished surfaces of concrete - Flat, complete all as specified and directed.
26
-
-
... More
Use and waste Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc - Rough finished surfaces of concrete - Flat, complete all as specified and directed.
16.75
-
-
... More
M&L mild steel TMT bars 10mm dia and over cut to length, bent to shape, required including cranking, bending, spirally for hopping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
1300
-
-
... More
Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
250
-
-
... More
M&L for fly ash Brick work with sub class 'B' bricks, straight or curved on plan exc 6m mean radius built in CM 1:6, complete all as specified and directed.
9.85
-
-
... More
M&L for Rendering 10mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces finishing the surfaces even and smooth without using extra cement, complete all as specified and directed.
44
-
-
... More
M&L for 15mm thick plaster in cement mortar 1:4 on other than fair faces of brick work or concrete surfaces finishing the surfaces even and smooth including making grooves, complete all as specified and directed.
51.5
-
-
... More
M&L rendering 10mm thick on concrete in CM 1:3 in facia or edging of chajjas,ceiling and roof projection making the line in true shape finished even & smooth without using extra cement, complete all as specified and directed.
11.5
-
-
... More
M&L for preparing the new plaster surface and applying two coats of oil bound distemper on ceiling, complete all as specified and directed.
11.5
-
-
... More
M&L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces, complete all as specified and directed.
51.5
-
-
... More
M&L for two coats of oil bound distemper over a coat of primer after applying 1 mm thick wall care putty on walls complete all as specified and directed
44
-
-
... More
M&L for broken stone or boulder hardcore of guage n exc 63mm, deposited, spread and levelled in layers n exc 15 cm thick, watered and rammed to a true surface, complete all as specified and directed.
1.75
-
-
... More
M&L 75 mm thick PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in sub base of floors etc and finishing the surface even and smooth without using extra cement, complete all as specified and directed.
31.5
-
-
... More
M&L 25 mm thick PCC 1:2:4 type B-0 using 12.5mm graded aggregate as in sub base of floors to receive topping layer complete all as specified and directed.
11.5
-
-
... More
Providing and laying of water proofing treatment of roof APP (Atactic Polyproplyllen) modified prefabricated five layer 3mm thick water proofing membrane, super thermply non woven polyester mat reinforcement of 160 gsm, weight of membrane @ 3.6 Kg/Sqm over a solvent based bitumen primer @ 0.3 Ltr Sqm by the same manufacturer conforming to IS:3384-1986 & M&L for providing 10mm thick rendering in Cement mortar 1:4 mixed with WPC 3% by weight of cement on fair faces of concrete, finished even and fair mixed with and including water proofing compound to receive treatment on roof The membrane shall be laid using bitmun torch.The end lap should be 100 mm and the side lap must be minimum 75 mm the membrane shall be first laid up to the parapet wall junction and then shall be overlapped with another membrane (flashing) with an overlap covering up to a distance of 300mm. In case parapet height is less than/ up to 500 mm, membrane shall be terminated at the top of parapet.All rain water pipe opening shall be suitably sealed with the APP membrane all as specified and directed including two coats of Aluminium paint after the treated surface complete
(The rate includes for filling cracks in existing roof with cement putty using suitable bonding agent (shalcrate 42) before laying cement plaster)
26
-
-
... More
Supply Only integral Water proofing compound
4
-
-
... More
M&L for machine pressed precast concrete interlocking paver blocks with grey cement and no pigment, any shape and size conforming to IS 15658:2006 of 80 mm thickness M35 grade complete all as specified and directed. Note-Shapes of interlocking paver block shall be triangular/Zigzag/Haxagon/or other ,Colour of paver blocks & laying pattern approved by Engr in charge.
20
-
-
... More
M&L rendering 10mm thick on concrete in CM 1:4 in facia or edging of chajjas, (width/height not exceeding 45 cm ) to protect movement of water inside and act in place of damaged drip course complete all as spd and directed.
20
-
-
... More
M&L for providing glazed ceramic coloured wall tiles of size 450mmx300mmx7mm thick, set, jointed in colour cement to match laid over and including 10 mm thick rendering in cement mortar 1:4 complete all as specified and directed.
11
-
-
... More
M&L 50mm thick PCC, type C-2, 1:3:6, ( using 20mm graded crushed stone aggregate) as in plinth protection finishing the surface even and smooth without using extra cement complete all as specified and directed.
9.75
-
-
... More
S&F steel window/ventilator with tubular frame factory made double shutters of size 79mm x 39mm, 16 gauge rectangular tubular frame with side hung shutter with glazing bars 12x3mm flat iron incl projecting type hinges with steel handle and steel peg stay dovetailed or welded incl 2 Nos tower bolts 75 mm long and 10mm square bar grills complete, including two coats of synthetic enamel paint over one coat of red oxide primer including sufficient nos of PCC bed blocks in pcc 1:2:4 (using 12.5mm gradded aggregate) for fixing hold fast & as shown on drg No CEPZ/ID-245/01 and 246/02 sheet ½ & 2/2.
7.5
-
-
... More
S&F sheet glass 3.00mm thick ordinary quality and glazing with oil putty in square n.exc 0.50Sqm in each panes including glass pin complete all as specified and directed.
1.4
-
-
... More
S&F glavinized mild steel wire cloths 0.46 mm nominal dia and average width of aperture 1.18mm & fixed with tint tacks or glavinized wire staples, complete all as specified and directed.
2
-
-
... More
S&F steel rolling shutter 1.00 mm thick with ball bearing and tension spring including top cover ,anchoring rod, hasp and staple and erected in position as indicated with oiling and greasing as required complete with gear operated type with bevel gear box and crank handle, complete all as specified and directed.
6
-
-
... More
M&L machine cut kota stone, stone slab flooring 20-25mm thick over screed bed 20 mm thick in cement mortar 1:4 set, jointed and pointed with grey cement slurry mixed with pigment to match the shade of the slab including, rubbing and granite polishing, complete all as specified and directed.
31.5
-
-
... More
Preparation of new steel surfaces of any description not otherwise described, over 10 cm width or girth and providing two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.
13.2
-
-
... More
M&L Framed work as in doors or gates of angle or other section with gusset plates, rails,braces, etc. complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (inclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing, complete all as specified and directed.
10
-
-
... More
S&F plate girder or single stanchion Fe-410 Grade A built up of one beam or channel section with flange plates caps bases splices, angle brackets cleats and other connection, complete all as specified and directed.
80
-
-
... More
Transportation of suitable RIG machine and all necessary machinery/T&P for drilling of bore hole (Telescopically) by mechanical Percussion method below the ground level pipe in any kind of soil strata (Boulder , conglomerate, rocks etc), disposal of surplus soil with in 100m, keeping space for pea gravel packing with system as recommended by CGWB report submitted by contractor and including lowring and extraction of casing pipes of suitable thickness as per IS 4270:2001 after lowering of assembly of ERW pipes, complete all specified and directed.
Note:- a) For laying casing pipe include all mechanical equipment shall be arranged by the contractor and the same shall remain property of the contractor after completion of the job/contract.
b) In case of non extraction of casing pipe due to failure of borewell the contractor will have no claim what so ever on this account.
-
-
-
... More
(a) 600 mm (24 inches) Bore hole:-
-
-
-
... More
From GL to 20 m Below ground level
20
-
-
... More
From 20 m Below ground level to 30 m Below ground level
10
-
-
... More
(b) 450 mm (18 inches) Bore hole:-
-
-
-
... More
From 30 m Below ground level 50 m Below ground level
20
-
-
... More
From 50 m Below ground level 70 m Below ground level
20
-
-
... More
(c) 380 mm (15 inches) Bore hole:-
-
-
-
... More
From 70 m Below ground level 90 m Below ground level
20
-
-
... More
From 90 m Below ground level 105 m Below ground level
15
-
-
... More
(d) 300 mm (12 inches) Bore hole:- From 105 m Below ground level 120 m Below ground level
16
-
-
... More
Supply , assembling, fixing & lowering of the liner tubewell asembly or strainer in position complete (net effective length shall only be measured and paid) all as specified and directed by Engr-in-charge as mentioned below :-
-
-
-
... More
Mild steel ERW screwed and socketed housing pipes 300 mm (12 inch) nominal bore having minimum 8 mm wall thickness conforming to IS : 4270-2001 & all around welded with 4 Nos : stiffeners of flat iron 40 x 6 mm, 300 mm long.
60
-
-
... More
Mild steel ERW screwed and socketed housing pipes 200 mm (8 inch) nominal bore having minimum 8 mm wall thickness conforming to IS : 4270-2001 & all around welded with 4 Nos : stiffeners of flat iron 40 x 6 mm, 300 mm long.
30
-
-
... More
Screen made of low carbon galvanised V wire, 200 mm dia bore having slot size 1 mm in suitable lengths as per IS 8110-2000 & all around welded with 4 nos : Stiffeners of flat iron 40 x 6 mm, 300 mm long.
30
-
-
... More
S&F for providing & fixing of 12" x 8" sleeve joint, complete all specified and directed.
1
-
-
... More
M & L for housing pipe clamp (to hold well assembly) made of MS flat 100mm x 12 mm 1.5 metre long (each Flap) made to shape suitable for 12 inch bore pipe including making two nos holes of 25 mm dia on both sides of flap and fixing with and including suitable size of nuts and bolts & washers complete all as specified and directed.
1
-
-
... More
S&F pea gravel of size 2 mm to 6 mm around the liner assembly from bottam to ground level including continuous watering during development. Complete all specified and directed.
30
-
-
... More
Providing & fixing of well cap for 300 mm bore pipe made out of MS pipe of suitable size 300 mm long duly internally threaded and covered with MS round MS flat not less than 6 mm thick duly welded 300 mm long 100 mm wide and 10 mmm thick MS flat on two sides of well cap fabricated complete all as specified and directed.
1
-
-
... More
Development of Tube well by means of pumping by air compressor of minimum pressure 10 Kg/cm, untill sand free and clean water is obtained at optimum yield as as specified below :-
-
-
-
... More
First 24 hours of develompent
1
-
-
... More
Subsequent development beyond 24 hours (if required)
94
-
-
... More
Supplying wooden (made out of IInd class hard wood )strata sample box with glazed shutter and pigeon holes not less than 100 mm for samples at every interval of 3 m complete all as specified and directed.
1
-
-
... More
Supply and fixing of 8"dia bail plug, complete all as specified and directed.
1
-
-
... More
supply and fixing of 50 x 6 mm centre guides of required size including welding to casing pipe, complete all as specified and directed.
25
-
-
... More
Construction of foundation to tubewell of size 1 m x 1m having 45 cm thick PCC 1:2:4 type b-1 (using 20 mm graded crushed stone aggregate) over 75 mm thick PCC 1:3;6 type C-2 with GI pipe 80 mm dia medium graded 04 Nos embedded throughout the block of suitabel length with GI plug, complete all as specified and directed.
1
-
-
... More
Supply, Installation, commissioning and testing of submersible pump set eletric driven 3 Phase 415 V 50 Hz with bronze impeller, high graded cast iron pump bowl, Motor casing, pump shaft and motor shaft made out of stainless steel suitable for 300/200 mm dia casing pipe and 100 mm delivery pipe with minimum 720 LPM discharge at 72 metres head of suitable power rating complete all as directed. Note: The head and discharge selection may be varied subject to bore well yield test within pump power rating upto 35HP. The Contractor shall submit efficiency curves & technical specification for approval before placing order.
1
-
-
... More
Discharge head assy suitable for 150 mm dia suction pipe and 150 mm dia dilivery pipe and bore casing size 300 mm dia with grounting the nuts and making the foundation, complete all as specified and directed.
1
-
-
... More
M&L for resistivity test to be carried out by Geologist and report to be submitted before drilling the borewell, complete all as specified and directed.
1
-
-
... More
S&F of Cl swing check NRV conforming to IS-5312, sutiable for 150 mm bore pipe consisting Cast iron Body, door as per IS 210, bronze body ring as per IS 318, natural rubber door face, hinge pin SS ASTM A276 type 410, fasteners as per IS 1367, Natural rubber gasket, etc complete double end flanged and drilled, of Class PN-1.6 (ISI marked) including all jointing materials such as rubber gasket insertion sheet nut ,bolts and washers etc complete all as specified and directed.
1
-
-
... More
Supply, laying and testing of ductile iron pipe (with jointing material) class K-7 of 150mm dia size Spigot and socket end with tyton joints in trenches/ on pedestals etc complete mortar lining (CML) and outside black bitumen coating etc, complete all as specifide and directed. Note: ( Earth work includes excavation, returning & filling and removal, DI fittings will be measured and paid separate where required).
180
-
-
... More
M&L of making column pipe fabricated out of 100 mm dia heavy grade GI pipe 3 metre long duly welded with MS flange on both sides ( MS Flanges thickness not less than 10 mm having 2 nos groove cuts to accommodate submersible cable , minimum 4 Nos holes drilled of suitable size) including fixing with suitable size of rubber gasket having thickness not less than 3 mm and jointing with and including suitable size of bolts & nuts and washers complete all required at work site.
90
-
-
... More
S&F of Cl sluice valve, non-rising type conforming to IS-14846, sutiable for 150 mm bore pipe consisting of SS spindle as per IS 6603, Cast iron Body, Dome & Wedge as per IS 210, greasy jute type gland packing, fasteners as per IS 1367, Natural rubber gasket, CI manual hand wheel etc complete double end flanged and drilled, of Class PN-1.6 ( ISI marked) including all jointing materials such as rubber gasket insertion sheet nut ,bolts and washers etc complete all as specified and directed.
3
-
-
... More
S&F CI fittings up to 150 mm bore such as (any type, bend/color/reducer and angle) tapers any type (straight,bends increasing,decreasing or double socket etc) tail pieces single branch Y junction,double branch cross (all sockets or socket ends spigot). All as required at work site and as directed.
200
-
-
... More
Cutting to existing CI/GI pipe line up to 150 mm dia and fixing of required CI fitting and connection including excvation and taking up & down threading, lead jointing, refixing in position in trenches & all as directed by Engr-in-charge. Note : CI fitting and GI flange will be measured and paid under relevent item
2
-
-
... More
S&F flanges on ends of CI/DI/GI pipe suitable for CI/ DI/ GI pipe of size 150 mm dia including necessery nut with bolt and washers all as specified and directed by Engr-in-charge.
4
-
-
... More
M&L for valve pit of size 120x120x105 Cm ( internal dimensions of the chamber) including and removing the debris at a distance not exceeding 50 Mtr and M/L for brick massonary with cement mortar with 1: 6 , 23 cm and flush pointing externaly work proceeds in the same mortar complete ( using 30% old bricks & 70% New bricks) complete with the following specifications and as directed by Engr-in-Charge.
Note :-(i) 10mm thick plaster internally in CM 1:6.(ii) Flooring 40mm thick in PCC 1:2:4 type B-1 over 75mm thick hard core of guage not exc 63mm thick. (iii) Angle iron frame 40X40X6mm thick for cover and mild steel 3mm thick cover with locking arrangement,handle and necessary hinges etc, (iv) PCC 1:3:6 type C-2 100mm thick in foundation .(v) Two coat of synthetic enamelled paint to cover internally and externally over a paint of Red Oxide primer.
2
-
-
... More
S&F GI tubing light grade 50 mm bore for cable protection including jointing complete all as specified and directed.
10
-
-
... More
S&F flate 3 core 1100V grade PVC insulated and seathed 16 Sqmm nominal area strandard copper conductor water proof cable suitable for submersible pump motor including connection cable to strater.
200
-
-
... More
M&L steel wire rope 3/8" dia with clamps of suitable size for securing the pump motor assembly.
100
-
-
... More
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1,5 mtrs in depth for laying of cables including getting out in any type of soil, complete all as specified and directed.
78.18
-
-
... More
Excavation over areas exceeding 1.5 meter wide and exc.1.5 meter in depth in any type of soil and getting out, complete all as specified and directed.
12
-
-
... More
Returning filling in including spreading, leveling ,and well ramming, in layers not exceeding 25 cm each layer of any kind of soil.
69.88
-
-
... More
Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point, complete all as specified and directed.
18.65
-
-
... More
M&L for good quality dry sand cushioning to under ground electric cable on layer of 8 cm thick before laying the cable and second layer of 15 cm thick after laying the cable, complete all as specified and directed.
9
-
-
... More
M&L for Brick covering with equal to length of brick as mechanical protection to cable with well burnt sub class 'B' bricks laid as directed.
955
-
-
... More
Supply laying & testing cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable (Heavy duty) with stranded aluminium conductor 1100 Volt graded size 3.5 core 120 Sqm.
120
-
-
... More
Supply install commissioning and testing floor mounted INdoor cubical type LT Panel Board(CPRI tested) of suitable size (minimum depth of pannel board should not be less than 45 cm) fabricated out of 2 mm thick CRCA Sheet and angle iron 50 X 50 X 6 mm frame factory made totally enclosed dust and vermin proof both side hinge opening arrangement on front and back with locking arrangement cable entry and exist from bottom with cable glands and gaskets, Aluminium bus bar fixed on porcelain insulator with internal wiring with suitable size of Aluminium strips to be used for incoming and outgoing connection of all switches/MCCB's & Bus-bar. Bus-bar shall be insulated with colour code sleeves/tapes and to be connected with Aluminium lugs, including two coats of synthetic enameled paint on the surface externally & internally over a coat of red oxide primer paint incl. necessary PCC (1 : 3 : 6) type C2 as in foundation all as directed, comprising of the following :- (i) Automatic Star delta strater Three Phase ,suitable for 45 HP capacity submersible pump set. -01 No (ii) MCCB FP 100 Amp 415 volt 50HZ AC supply 25 KA -01 No (iii) MCCB FP 63 amp 415 volt 50HZ AC supply 16 KA -01 No (iv) Digital type Volt meter, range 0 to 500 Volt with slector switch and PT. - 01 No (v) Digital type Ameter , range 0 to 600 Amp with slector switch and CT -01 No (vi) Indicator lamp RYB.- 01 set (vii) Single phase priventer,-01 No (viii) Under voltage protection relay. -01 No (ix) MCB TPN 40 amp 10 KA - 01 No
1
-
-
... More
M&L carrying out water test from auth Govt Lab for physical test and chemical test and test for pesticides etc.
1
-
-
... More
M&L for CI water meter Woltman type Magnetic Drive Class-B Flanged end of size 150 mm complete all as directed by Engr -in-Charge.
1
-
-
... More
S&F of Adjustable High pressure, power input 230 V, 50 Hz 40 Spm 1/30 fractional horse power, working pressure upto 15 Kg/sq cm& max output 0-30 ltr/hr with mandatory accessories like lead tubing, connecting ferrule, injector check valve,etc. Accessories must include following:- Preparation tank of min capacity 170 ltrs. FRP dosing tank dia 650X net height 375 + conical 300mm, gross height with stand 1000mm consisting of water inlet line, outlet with Y strainer. Drain, overflow, conical bottom for sludge deposition, pot hole cover, level gauge, Agitator 120 watt 900 rpm single phase flange mounted motor with plastic shaft and impeller and service tank of net capacity 100 ltrs of FRP dosing tank consisting of water inlet line, dosing pump inlet arrangement, drain, overflow level gauge, inspection port, etc along with all the other accessories as per site requirement complete all as specified and directed by Engr-in-Charge.
1
-
-
... More
M&L for modular point wiring with 1.5 sqmm (nominal area) PVC insulated FRLS and unsheathed multistranded copper conductor cable 1100 volts grade drawn through and including PVC rigid concealed conduit not less than 1.8 mm thick (ISI marked) with all accessories including suitable modular plate (Inner + Outer) and modular metalic boxes of suitable sizes including 1.5 sqmm PVC FRLS insulated unsheathed copper conductor multistranded cable for continuous earth conductor connected to common earth dolly, complete all as specified & directed for the following Note:- Proper colour coding is to be followed as per IS Specification.
-
-
-
... More
All as per Srl item No. 77 above but for One light controlled by one switch 5 Amp, SP, one way 240 volts.
3
-
-
... More
All as per Srl item No. 77 above but for One multi pin socket 5 Amp on same board
1
-
-
... More
Supply, fixing, stringing and drawing submain wiring with 2 run of single core, 4 sqmm PVC insulated and unsheathed, multi stranded copper conductor cable FRLS using colour code for phase red and neutral black with and including 4 sqmm PVC insulated and unsheathed FRLS conductor multi stranded cable in green colou connected to common earth point and connected to earth dolly drawn through PVC rigid conduit 20 mm bore, heavy grade (ISI marked) with and including all accessories, fixed to surface / recessed for Geyser connection complete all as specified and directed.
10
-
-
... More
S&F Modular switch 1 way 6A,1 module single, ( ISI marked) complete all as specified and directed.
4
-
-
... More
S&F Socket, 6A - 2/3 pin combined 2 module, (ISI marked) complete all as specified and directed. .
1
-
-
... More
S&F ceiling rose surface bakelite 65 x 50mm, three terminals ISI(Marked) all as specified and directed.
3
-
-
... More
S&F of LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube rod 20 watt with polycarbonate diffuser of 4 feet box type made of CRCA sheet and connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and directed.
2
-
-
... More
S&F High performance IP66 LED Streetlight 20 watt, housing made of die-cast aluminium, with street optic lens,with all accessories and connecting up with and including provision of 3 core flexible copper wire of size 1.5sqmm from ceiling rose, and 20W LED light etc. drawn through and including 32mm bore GI light grade protecion pipe upto 1.0m length with suitable fixing accessories on walls, complete all as specified and as directedcomplete all as specified and as directed.
1
-
-
... More
S&F SPN 4 way sheet metal enclosures factory made DB double door 230 V AC, 50 Hz AC, complete all as specified and directed
1
-
-
... More
S&F 240V, 10 KA miniaturecircuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning, complete all as specified and directed.
2
-
-
... More
S&F amp rating 240V, miniature circuit breaker (MCB) of SPN 32 Amp current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
1
-
-
... More
S&F for Y type Strainer, Cast Iron body, Stainless steel Screen, type 304,Gasket C.N.A.F,Cast Iron Cover, Carbon Steel Bolts, Cast Iron Drain Plug, PN - 16, flanged type Dia 150 mm size, complete all as specified & directed.
1
-
-
... More
M&L earthing with steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 2.5 mtr deep below nrmal ground leval connected to galvanized iron strip of size 32 x 6 mm as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full length of earth plate , 40 mm dia GI tubing light grade protection pipe upto test point, 20 mm dia GI waterring pipe ith funnel and wire mesh, PCC pit 1:3:6 with pit cover of size 300 mm x 300 mm x 40 mm made of RCC 1:2:4 with suitable handle, angle iron frame made of angle iron of size 40 mm x 40 mm x 4 mm, adequate qty of charcoal dust and salt layers all around the earth plate, removal of surplus soil and returning filling including test point made out of steel plate of size 75 mm x 75 mm x 6 mm fixed to wall complete all as specified and shown i electrical plate no 3 of SSR Part-1 and directed. Note - 1. Earth strip & protection pipes length upto & including 7.50 metre is deemed included in unit rate quoted by the contractor.
2. Earth filling shall be done by vegitable soil.
3. Soil shall be free from stone, boulders, aggregate, gravels.
2
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%