Military Engineer Services Tender
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Costs
EMD
₹ 99,600Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_692482_1Tender No
8858/2024-25/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
REPAIRS /MAINTENANCE OF STPs AT DIFFERENT LOCATIONS UNDER GE (U) BATHINDA.
REPAIRS /MAINTENANCE OF STPs AT DIFFERENT LOCATIONS UNDER GE (U) BATHINDA.
REPAIRS /MAINTENANCE OF STPs AT DIFFERENT LOCATIONS UNDER GE (U) BATHINDA.
BOQ Items
... More
Cleaning,removing and bailing out stagnated sewage or sludge from walls/floor and any light particle with the help of pressure jet pump & other required equipments from MBBR/FAB Reactor reactor inner surface off sizes and taking out damaged and unbroken MBBR media without any damage and refilling it in each MBBR with old unbroken media cleaning of inner and outer surface of MS pipe placed in MBBR and removing any sludge particle from it to entire satisfaction of Engineer-in-Charge. (All STPs) Note : New media for topping up will be paid and measured separately under respective item of BOQ.
8
-
-
... More
Cleaning and removing of sludge from walls/floor of tube settler tank off sizes after taking out the tube settler media including cleaning of filter feed tank with the help of pressure jet pump & other required equipments and depositing where directed at a distance 100 mtr away from outer wall of STP including taking out old rusted wire mesh of sizes from tube settler media and cleaning the tube settler after all cleaning fixing wire mesh of same size with the tube settler and fixed in original position in the tube settler tank including painting to steel surfaces by using black bitumen paint and white wash to walls complete all as directed (All STPs).
8
-
-
... More
Cleaning of existing DMF by opening the lid off sizes and removing deposition completely, cleaning of inside scaling and clear the deposition topping of media as required quantity of sizes complete all as directed. (All STPs)
8
-
-
... More
Cleaning of existing ACF by opening the lid of sizes and removing deposition completely, cleaning of inside scaling and clear the deposition topping of media as required quantity of sizes complete all as directed. (All STPs)
8
-
-
... More
Cleaning and removing of sludge from walls/floor of Raw Water Collection Tank located at various places with the help of pressure jet pump & other required equipments and depositing where directed at a distance 100 mtr away from outer wall of Raw Sewage Collection Tank including bailing out all material from inside the tank including complete all as directed. (Shivaji Pump house No 01, 02 & 03, Ranjit/Gobind Raw Sewage Tank, Jadunath Raw Sewage PH, Gurnam Enclave Raw sewage collection tank).
6
-
-
... More
Cleaning and removing sludge from walls /floor of Treated water tank (located at 11 different locations for arboriculture) with the help of pressure jet pump & other required equipments and depositing where directed by Engineer-in-Charge at a distance 100 mtr away from outer wall of STP and white wash to walls complete all as directed by Engineer-in-Charge.
22
-
-
... More
Taking out solid dry sewage waste from 06 x sludge beds (except shivaji STPs where only three beds) off sizes and removing to a distance not exc 50 mtr from outer edge of Sewage treatment plant for further disposal complete all as directed.(All STPs)
8
-
-
... More
M&L for area cleaning under pumphouse premises as cutting/scraping of grass, unwanted trees, plant, levelling of earth surfaces, filling of digs etc complete all as directed.
7000
-
-
... More
Dismantling the electric induction motor AC 3 Phase, capacity upto 7.5HP, irrespective make and type from the foundation and pump after disconnecting electric cable connection and earthing etc. and transportation to civil workshop for repair, if required, for overhauling the motor duly painted with two coats of synthetic enamel paint of existing shed and re-assembling the complete motor and installing at site with electric cable connection for its serviceability up to entire satisfaction of Engineer-in-charge.
Note:- (i) Cost of copper wire, T&P, minor repair incl minor spare included in this item.
12
-
-
... More
Dismantling the electric induction motor AC 3 Phase, capacity above 7.5HP, irrespective make and type from the foundation and pump after disconnecting electric cable connection and earthing etc. and transportation to civil workshop for repair, if required, for overhauling the motor duly painted with two coats of synthetic enamel paint of existing shed and re-assembling the complete motor and installing at site with electric cable connection for its serviceability up to entire satisfaction of Engineer-in-charge.
Note:- (i) Cost of copper wire, T&P, minor repair incl minor spare included in this item.
5
-
-
... More
Disconnecting the centrifugal/monoblock pumping sets off sizes & any make from motor and all water connections and removing/taking up from foundation transporting to civil workshop for repair/strip opening and repairing of pumping sets by changing defective/unserviceable parts such as bearing,shaft,impeller,bush,gland plate etc complete.Re-assembling including oiling greasing replacement of worn out nuts,bolts gasket etc,and installing in its original position at site making all connection, commissioning and testing etc complete all as directed.
10
-
-
... More
Supply only steel distance pieces suitable upto 40 HP centrifugal/monoblock pumping sets complete all as directed.
1
-
-
... More
Supply only gland plates with studs/ eye bolt suitable for centrifugal/monoblock pumping set off any sizes pumping set of any make complete all as directed.
2
-
-
... More
Supply only carbon steel shaft high tensile strength with key suitable for centrifugal/monoblock pumping setof any sizes as per site requirement.
1
-
-
... More
Supply only cast iron impeller suitable for centrifugal/monoblock pumping set off any capacity as per site requirement.
2
-
-
... More
Supply and fixing in repair MCCB (Sizes 63A, 100A & 125 Amp as per site requirement), 415 Volts, TP, 50 cycle, breaking capacity 35KA complete all as directed.
10
-
-
... More
Supply and fixing in repair MCCB, (sizes 200A & 250A as per site requirement), 415 Volts, 4Pole/3 Pole , 50 cycle, breaking capacity 35KA complete all as directed.
4
-
-
... More
Disconnecting Air Blower of capacity upto 25 HP, any make and types from the foundation and disconnection of motor, all electric cable connection and earthing etc. and transportation to civil workshop if required and over hauling includign changing of necessary parts, greasing, painting, oiling and re-assembling the complete set & re-installation fo blower set at site with existing electric cable connection for its serviceability up to entire satisfaction of Engineer-in-charge .
Note:- (i) Cost of M&L, T&P, greasing, oiling & other minor spare is included in this item. Nothing extra shall be paid on this account. (ii) Major parts to be measured and paid separately under respective sch of items.
20
-
-
... More
M & L for removing of all items for like MCCB, Contactor, relays etc and refix the same duly cleaning/removing carbon etc scaling from LT Panel existed at Various STPs under GE Utility Bathinda complete all as specified and as directed.
Note : (i) MCCB, Contactor etc measured and paid separately. cost of minor parts like thimble, MCBs upto 32A and labour charges included in this item. No extra cost to be paid for this.
7
-
-
... More
Supply and fixing in repair ball bearing of DE & NDE for electric motor of any capacity upto 40 HP complete all as directed.
10
-
-
... More
Lifting the submersible pump and motor of capacity upo 7.5HP, complete after disconnecting electric cable connection and transportating to civil workshop if required for overhauling reassembling the complete submersible pump and motor lowering including reconnecting the electric cable connection and testing complete all as directed by Engineer-in-Charge.
Note: Cost of minor parts like grease, nut bolt etc is included in this rate and nothing extra to be paid on this account.
12
-
-
... More
Lifting the submersible pump and motor of capacity above 7.5HP, complete after disconnecting electric cable connection and transportating to civil workshop if required for overhauling reassembling the complete submersible pump and motor lowering including reconnecting the electric cable connection and testing complete all as directed by Engineer-in-Charge.
Note: Cost of minor parts like grease, nut bolt etc is included in this rate and nothing extra to be paid on this account.
4
-
-
... More
Supply and fixing in repair mechanical seal & oil seal for pumping set of any capacity complete all as directed.
10
-
-
... More
Supply and fixing in repair Relay of upto 23Amp ranges and suitable for upto 7.5HP starter (Dol/Star delta) complete all as directed.
10
-
-
... More
Supply and fixing in repair Relay range (above 23Amp) for above 12.5 HP to 40HP starter(Dol/Star delta) ocomplete all as directed.
6
-
-
... More
Supply and fixing in repair blower belts of any size (as per site requirement) for Air Blower electric motor complete all as directed.
60
-
-
... More
Supply and fixing in repair power Contactors 415 volts, 50 cycles, 3 phase, MNX-A2 or MNX A1 complete all as directed.
6
-
-
... More
Supply and fixing in repair power Contactors 415 volts, 50 cycles,3 phase MCX 33 complete all as directed.
2
-
-
... More
Supply and fixing in repair ball bearing of any sizes suitable for Air blower off any capacity complete all as directed.
12
-
-
... More
Supply only chlorine dioxide powder (SCK 10K) chemical for treatment of raw sewage treated water complete all as directed.
950
-
-
... More
Taking out CI foot valve/Non return valve of any size from jack well approximate 3 mtr deep and refixing the same in original positions after fixing leather buffalow complete all as required at site and as directed.
Note : Leather buffalow /nut bolts and rubber sheet will be measured and paid seperately under appropriate item of BOQ as supply only.
15
-
-
... More
Supply only leather buffalow superior quality as per sample complete all as directed.
35
-
-
... More
Supply only oil imeressed graphite gland packing off sizes of superior quality along with grease and cotton waste complete all as directed.
20
-
-
... More
Supply and fix in repair submersible flat copper cable multi stranded 10 Sqmm, 3 core including connection and testing complete all as directed.
200
-
-
... More
Supply only air compressor oil for air blower complete all as directed.
100
-
-
... More
Material and labour for detecting and repairing the sewage leakage in already laid GI pipeline of any upto 100mm bore (Treated Sewage water pipeline) including necessary excavation and earth work, bailing out stagnated /muddy sewage water complete all as directed by Engineer-in-Charge.
60
-
-
... More
Material and labour for detecting and repairing the sewage leakage in already laid CI/MS pipeline of 100/150/200mm bore from last manhole to Raw Sewage Pump House, including necessary excavation and earth work, bailing out stagnated /muddy sewage water complete all as directed by Engineer-in-Charge.
40
-
-
... More
M & L for preparation of old steel and iron surfaces of any description over 10 cm in width or girth and applying one coat of synthetic enemal paint of any tint complete all as specified and directed by Engineer-in-Charge.
200
-
-
... More
Supply and fixing in repair Cast Iron butterfly valves of size 150 mm dia complete all as directed.
2
-
-
... More
Supply and fixing in repair Cast Iron butterfly valves of size 125 mm dia complete all as directed.
1
-
-
... More
Supply and fixing in repair Cast Iron butterfly valves of size 100 mm dia complete all as directed.
35
-
-
... More
Supply and fixing in repair Cast Iron butterfly valves of size 80 mm dia complete all as directed.
4
-
-
... More
Supply and fixing in repair Cast Iron butterfly valves of size 40/50 mm dia complete all as directed.
10
-
-
... More
S&F in repair 80 mm dia sluice valve, ISI marked PN 1.6 confirming to IS-14846-2000, both end flanged ,drilled , steel spindle and iron wheel handle, CI gate with MS ring including jointing material such as nuts, bolts, washers and rubber sheet etc complete all as directed.
Make KIRLOSKAR / LEADER / L&T /UPADHYA / ZOLOTO/ BIR
2
-
-
... More
All as per serial item No. 49 above but for 100 mm dia sluice valve.
2
-
-
... More
S&F in repair 100 mm dia NRV, ISI marked PN 1.6 both end flanged ,drilled, including jointing material such as nuts, bolts, washers and rubber sheet etc complete all as directed.
5
-
-
... More
Supply and replacement of existing unserviceable LED 60 Watts for street lights complete all as specified and directed by Engr-in-charge.
20
-
-
... More
Frame work as in doors or gates of angle or other section with gusset plates, rails, braces etc complete, drilled for fixing of steel sheeting or other covering. doors, etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete conforming to Fe.290.Gde-E-165 complete all as specified and dirtected by Engineer-in-Charge.
450
-
-
... More
Supplying, Laying, jointing and testing of GI steel water tubing 100 mm bore ISI marked heavy grade galvanised including flanged ended & including tube fittings Viz Tees, Socket bends elbows, union nipple etc screwed and socketed joint including taking out existing pipe from sumpwell complete all as specified and directed.
Make : Jindal/Surya Prakash/RAWALWASIA STEEL PLANT PVT LTD, HISAR (BST).BST
50
-
-
... More
All as per serial item No. 54 above but for GI pipe of 80 mm bore.
18
-
-
... More
All as per serial item No. 54 above but for GI pipe of 25 mm bore.
100
-
-
... More
Testing of Raw Sewage Water (Inlet) parameters like BOD, COD, TSS, FC, pH, Total N, from Government approved Lab including proper collection sample in presence of all concerned. The transportation charges and all other expenses are deemed to be included in this rate. No extra charges are given to the bidder.
48
-
-
... More
Testing of Treated Sewage Water (outlet) parameters like BOD, COD, TSS, FC, pH, Total N, from Government approved Lab including proper collection sample in presence of all concerned. The transportation charges and all other expenses are deemed to be included in this rate. No extra charges are given to the bidder.
48
-
-
... More
Supply and fixing in repair 80 mm dia Air Release Valve, ISI marked along with 1 mtr GI pipeline of same dia and all connected fittings, including jointing material such as nuts, bolts, washers and rubber sheet complete all directed.
3
-
-
... More
M&L for earthing complete with galvanized iron of steel or earth plate Each electrode of size 600mm x 600mm x 6mm thick buried directly in ground. Vertically total depth not less than 2.25 mtr below normal ground level with top edge of earth plate at depth of not less than 1.5 mtr below ground level surounded from all sides with alternate layers of charcoal and common salt and connected to GI earth strip 25mm x 4 mm thick by means of GI bolts, nuts washers & check nuts and soldering the strip, electrode connected to panel board or on poles or on transformer (including making of test point with GI strip of size 25mm x 4 mm) including GI protection pipe 40 mm light grade dia for protection of strip upto test point all as directed GI pipe medium grade 20 mm bore for watering including providing funnel and wire mesh CI frame and 10 cm thick suitably reinforced RCC pit cover PCC chamber pit with PCC 1:3:6 type C2 using 40 mm graded stone aggregates complete including excavation and earth work, all as specified and PCC pit shall be provided at least 50 cm away from the earth pit and not just on earth pit including testing on completion.
Make of GI Pipe- TATA / JINDAL / ZENITH / SWASTIK PIPE PVT LTD / PRAKASH SURYA /BST.
20
-
-
... More
Supply and adding of MBBR media to treat water in all STPs located at different places complete all as directed and specified by Engineer-in-Charge.
21
-
-
... More
Replacement of outdated bacteria in MBBR reactor & tube settle to make decomposition process fast and effective complete all as directed.
200
-
-
... More
Fixing, installation, testing and commissioning of Non clog sewage Submersible pump of capacity 20 HP including all electrical and and mechanical connection upto entire satisfaciton of Engineer-in-Charge. Note : Labour charges including T&P required to fixing the pump is responsibility of contractor. Nothing extra shall be paid on this account.
4
-
-
... More
Note:- The contractor shall deposited the old material retrived from item no 01 to 61 to AGE E/M (Water Supply and Refg) store yard by his own arrangements without any financial benefits and shall maintain the record for the same as specified by Engr-In-Charge and GE.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%