Military Engineer Services Tender
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Military Engineer Services - MES Tender
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date13 May 2024
Closing Date6 Jun 2024
Tender Amount₹ 25,00,000
Costs
EMD
₹ 50,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_653725_1Bid Award Id
ViewTender No
AGE (I)/DPR/T-07/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Material & Labour for Galvanised Iron Pipe 20 mm dia medium grade galvanised with all fittings and fixed complete laid as in trenches / floor icluding taking down of existing pipes complete all as specified and directed by Engr-in-Charge.
300
-
-
All as per item No-4 here in before but 25 MM.
200
-
-
All as per item No-4 here in before but 40 MM.
150
-
-
All as per item No-4 here in before but 50 MM.
150
-
-
All as per item No-4 here in before but 80 MM.
100
-
-
S&F centrifugally cast (spun) ductile iron pressure pipes with socket& spigot ends having ISI stamping marking with IS 8329/2000 classification K7, In standard length of 5.5 - 6 mtr suitable for and including push on joint (gassket D jointing) with cement mortar lining in the pipes including taking out GI/DI pipe ,75/80/100 MM, complete all as specified & directed of 100 mm dia complete all as specified and directed.
250
-
-
All as per item No-09 here in before but 150 MM.
150
-
-
Supply & Fixing in repairs DI fittings for flanged & spigot socketed pipe e.g. bends (any type, radius and angle), tapers any type, (straight, bend, increasing, decreasing or double socket etc) tee pieces, collars, caps and plugs conforming to IS of size upto 200/ 150/100 mm bore complete all as specified and directed.
200
-
-
Supply and fix in repairs Gun Metal gate valve with Iron wheel head screwed both ends for GI steel tubing 20 mm dia including taking down unserviceable valves complete all as specified and directed by Engr-in-Charge.
24
-
-
All as per item No-12 here in before but 25 MM.
18
-
-
All as per item No-12 here in before but 40 MM.
10
-
-
All as per item No-12 here in before but 50 MM.
10
-
-
Taking out defective Supply & fix cast iron sluice valve 100 mm dia, flanged ends,stem (spindle) of SS (forged) and check nut of gun Metal, PN rating 1.6,working parts conforming to IS :14846, and flanged ends having drilling as per IS:1538 including taking down old unserviceable sluice valve complete all as specified and directed by Engr-in-Charge.
4
-
-
All as per item No 16 here in before but of size 150MM.
5
-
-
All as per item No 16 here in before but of size 200MM.
1
-
-
All as per item No 16 here in before but of size 80 MM.
5
-
-
Painting of CI/DI/GI pipes of size 100/150/200 mm/ MS pit cover with two coats of synthetic enamel paint after scratching the existing paint properly and cleaning the surface properly all as specified and directed by Engineer-in-charge.
100
-
-
Supply and fix in replacement of unserviceable Pressure gauge 100 mm dia with ball valve of pressure 0-21 Kg/Sqcm with matching thread of specification & make.
10
-
-
Supply, Fixing in repairs jointing Cast Iron non return (reflux) valve ISI marked, flanged ends in swing type design is:5312 part-1 class PN 1.6 with flanged and drilled ends suitable for 150 mm nominal bore pipe having gun metal seat etc complete & including joints and jointing material such as bolts, nuts, washers and rubber gaskets, complete all as directed.
3
-
-
M&L in repairs for Fixing & jointing Cast Iron non return (reflux)/ valve ISI marked, flanged ends, class PN 1.6 with flanged and drilled ends suitable for 100 mm nominal bore pipe complete with all acessories & including joints and jointing material such as bolts, nuts, washers and rubber gaskets, complete all as directed.
2
-
-
M&L in repairs for Fixing & jointing Cast Iron Air release valve ISI marked, flanged ends, class PN 1.6 with flanged and drilled ends suitable for 100 mm nominal bore pipe complete with all acessories & including joints and jointing material such as bolts, nuts, washers and rubber gaskets, complete all as directed.
5
-
-
M&L in repairs for Fixing & jointing Cast Iron Air release valve ISI marked, flanged ends, class PN 1.6 with flanged and drilled ends suitable for 150 mm nominal bore pipe complete with all acessories & including joints and jointing material such as bolts, nuts, washers and rubber gaskets, complete all as directed.
3
-
-
Dismantling and taking up submersible pumps set of any capacity and any size from bore well with the help of chain pulley block including dismaintling the MS/GI column pipe up to 115 mtr and electrical mechanical connection transportation from site to authorised workshop at Ambala /Chandigarh for carrying out necessary repairs /replacement of defective / worn out parts and back to site, lowering the submercible pump set in to borewell after testing including connecting coulmn pipe and cable connection etc, after completion of the work testing of pump set on load to the entire satisfaction of Engr-in-Charge and reading the data complete. Note :- (i) T&P required for raising & lowering, the pumps and pipes will be arranged by contractor and the cost deemed to be included in the unit rate quoted by the contrator for this items.
(ii) Small items such as nuts, bolts washers and rubber gasket required will be included in the item rate.
(iii) Spare parts for repair will be measured and paid separately. ( Pump No. 8)
1
-
-
Strip opening of Pump set complete of Capacity 40/41 HP and removing scales, cleaning serviceable parts and re-assembling after carrying out repairs / replacement of worn out parts including seals, 'o'rings, washers, nuts and bolts as required and making the pump set fully serviceable and testing to the entire satisfaction of Engr-in-charge complete all as specified and directed. Note :- (i) Spares for replacement will be measured & paid separately under respective items herein after supply only.
(ii) Replacement of all other items such as seals, 'o'ring , washers, nuts and bolts will be deemed to be included in rate quoted against this item. ( Pump No. 8)
1
-
-
Supply only of the following new items suitable for pump set of capacity 40/41 HP in lieu of unserviceable parts. (a) Impeller of existing specification.
6
-
-
(b) Stage sleeve of existing specification and make.
6
-
-
(c) Stage bush of existing specification and make.
8
-
-
(d) Gasket of existing specification and make.
8
-
-
(e) Bushing sleeve of existing specification and make.
8
-
-
(f) Bearing Bush of existing specification and make.
4
-
-
(g) Pump shaft of existing specification and make.
1
-
-
(h) Pump key of existing specification and make.
1
-
-
(j) Space sleeve of existing specification and make.
1
-
-
(k) Suction stainer of existing specification and make.
1
-
-
(l) Shaft sleeve for motor of existing specification and make.
1
-
-
(m) Cable packing pipe of existing specification and make.
1
-
-
(n) Cable gland ring of existing specification and make.
1
-
-
(o) Bearing Bush for motor of existing specification and make.
2
-
-
(p) Bearing sleeve for motor of existing specification and make.
2
-
-
(q) Bowl assembly complete with accessories of existing specification and make.
4
-
-
(r) Sleeve coupling of existing specification and make.
1
-
-
Material and labour strip opening of submersible motor for 41/40 HP pumping set and taking out burnt copper conductor and cleaning of stator and rotor surfaces and carrying out new re-winding with existing size, and weight gauge / suitable size and weight of copper conductor and providing new insulating material of 'F' class insulation, heating varnishing, drying through electric furnance and testing on specified load all as specified & directed by Engr-in-Charge. ( Pump No. 8)
1
-
-
Supply, lowering, jointing, testing and commissioning GI pipe heavy duty 100mm internal dia (3 mtr long with both ends threaded and fitted with heavy duty MS flanges 14mm thick, two Nos groves for submersible cable continuous welded and drilled 4 Nos hole, complete as column pipe including jointing material such as bolts, nuts, washers and rubber gasket etc complete all as specified. ( Pump No. 8)
1
-
-
M& L for attending complaint as and when required , taking out old unserviceable GI pipe of 20 mm dia pipe cutting at location/ site to remove rusted/ damaged pipe including S&F for connecting new pipe in replacement of length 0.5 RM with the existing pipe line, including testing of pipe line so repaired for complete satisfaction of Engr-in- Charge.
Note:- 1.Excavation, Removal & Returning filling of soil (soft/hard) is deemed to be inclusive in the quoted rate.
2. Cost of GI fittings like socket, union, tees, long screw, nipple, hexa nipple, reducer etc is deemed to be included in the quoted rate.
3. Length of pipes required to be replaced if is more than 0.5 RM the same will be measured in the relevant items of this schedule.
60
-
-
Description all as per ser item No 47 here-in-before but GI pipe line of 25 mm dia
50
-
-
Description all as per ser item No 47 here-in-before but GI pipe line of 40/50 mm dia
20
-
-
Description all as per ser item No 47 here-in-before but GI pipe line of 80 mm dia
15
-
-
M&L taking out 100mm dia sluice valves and re-facing, regrinding replacing stuffing boxes of sluice valve spindle and gland plate replacement of gasket, nuts, bolts, washers and reassembling in existing state including excavation and earth work and making the disturbed surface as per existing surface after making the sluice valve serviceable to the entire satisfaction of Engineer-in-Charge.
2
-
-
Description all as per ser item no 51 here-in-before but Sluice Valve of 150 mm dia
1
-
-
Supply and laying of 100mm bore Cast Iron Pipe class 'LA' centrifugally cast with spigot and socket ends laid in trenches complete all as specified and directed by Engr-in-charge.
11
-
-
Description all as per ser item No 53 here-in-before but Cast Iron pipe of 150 mm dia CLASS 'B'
11
-
-
Cutting CI pipes and reducing to required length in position for inserting of new tees branches, collors, bends etc for 100/150 mm dia pipes complete all as specified and directed by Engr-in-Charge. (Both sides cutting shall be measured as one unit)
2
-
-
Materal for providing run lead joints for spigot and socket CI pipes of 100 mm dia including lead and sutlee etc complete all as specified and directed by Engr-in-Charge.
5
-
-
Description all as per ser item No 56 here-in-before but lead joint for CI Pipe of 150 mm dia
6
-
-
Description all as per ser item No 56 here-in-before but lead joint for CI Pipe of 200 mm dia
2
-
-
Material and labour construction of brick masonary valve pit of size 1200 mm x 1200mm x 1200 mm (Internal size) thickness of walls shall be 23cm in brick work in cm 1:6 internally plastered in cm (1:6) and externally plastered in cm (1:4) over 15cm thick PCC 1:4:8 type D-2 having 15m offset around, including 4 cm thick coping in PCC 1:2:4 type B-1 as the top of the brick wall and 3mm thick mild steel sheet cover and angle iron frame of size 40 mm x 40mm x 6mm including provn of suitable hold fasts to hold the frame, locking arrangement and lifting handle, duly painted with two coats of synthetic enamel paint, over a coat of red oxide primer complete all as specified and as directed by Engr-in-Charge .
6
-
-
Material and labour construction of brick masonary valve pit of size 900 mm x 900mm x 900 mm (Internal size) thickness of walls shall be 23cm in brick work in cm 1:6 internally plastered in cm (1:6) and externally plastered in cm (1:4) over 15cm thick PCC 1:4:8 type D-2 having 15m offset around, including 4 cm thick coping in PCC 1:2:4 type B-1 as the top of the brick wall and 3mm thick mild steel sheet cover and angle iron frame of size 40 mm x 40mm x 6mm including provn of suitable hold fasts to hold the frame, locking arrangement and lifting handle, duly painted with two coats of synthetic enamel paint, over a coat of red oxide primer complete all as specified and as directed by Engr-in-Charge .
4
-
-
Supply and fix D-Joint of 80 mm dia in CI/DI pipe line to stop leakage with all necessary items which is required for to stop leakage including necessary excavation and refilling all as specified and directed.
4
-
-
Supply and fix D-Joint of 100 mm dia in CI/DI pipe line to stop leakage with all necessary items which is required for to stop leakage including necessary excavation and refilling all as specified and directed.
3
-
-
Demolition of brick work built in cement mortar incl all quoins, arches, pillars, in any situation etc complete all as specified and directed by Engr-in-Charge.
1.5
-
-
Material and labour brick work with sub class 'B' bricks straight or curved on plan exc 6 m mean radius built in CM 1:6 complete all as specified and directed by Engr-in-Charge.
1
-
-
Description all as above hereinbefore ser item no.66 but except brick complete all as specified and directed by Engr-in-Charge.(Serviceble Old bricks obtain from ser item No shall be reused after cleaning).
0.5
-
-
Material and labour 15 mm thick cement plaster in cement mortar 1:4 on fair faces of brick walls or concrete external surfaces finished even & fair without using extra cement, complete including white wash all as specified and directed by Engr-in-Charge.
3
-
-
Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed by Engr-in-Charge.
1
-
-
Material and labour Cement concrete 1:2:4 type B1 using 20mm graded mechanically crushed stone aggregate as in coping and foundations for DG etc complete all as specified and directed by Engr-in-Charge.
1
-
-
S & F Joint, channel, angle, or tee sections, fixed independently with welding, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) of Fe-410W(GdeE-250) qualityB against worn out channel, angle iron etc complete all as specified and directed by Engr-in-Charge.
150
-
-
Material and lobour replacement of worn out flat submersible PVC insulated 3 core copper conductor size of 25 Sqm 1100V grade, 50 Hz for submersible.
120
-
-
Dismantling and taking out submersible pumps set of10/ 20/30/ 40/41HP capacity and any size from bore well with the help of chain pulley block including dismantling the MS/GI column pipe, and change nuts bolts washers, good quailty ISI marked rubber gasket, lowering the submersible pump set in to borewell after testing including connecting coulmn pipes and cable connections etc, after completion of the work testing of pump set on load to the entire satisfaction of Engr-in-Charge and reading the data complete. 9 For development of bore well)
Note :- (i) T&P required for raising & lowering, the pumps and pipes will be arranged by contractor and the cost deemed to be included in the unit rate quoted by the contrator for there items.
(ii) Small items such as nuts, bolts washers and rubber gasket required will be included in the unit rate for these items. (Pump No 8)
1
-
-
Development of tube well by air compressor of capacity not less than 500 CFM at 150 to 200 PSIG approximate capacity as required on ground till to get clear water complete including all T&P , Diesel and other materiel required at site and carrying out yield test complete. ( Pump No 8)
10
-
-
M & L in repair for Gun metal Stop valves 15MM dia, cast copper alloy, screwed down, high pressure,with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed.
1
-
-
Taking out water sample in containers and getting the water tested from the department of water test examination from govt approved NABL Lab aur NIIRT- Centre for Calibtation, analysis and Testing for chemical & Bacteriological test complete all as directed by Engr-in-Charge for following locations:-
(a) PH No 8
(b) PH No GP 2
(c) PH No 2A
(d) PH No 7 (e) PH No 6
(f) PH No 9 Parameter (Test Periodicity:- Quaterly Once all in Five Pump House)
a. (i) Colour, (ii) Turbidity, (iii) Residual Chlorine, (iv) Total Chlorine
b. (i) PH, (ii) Chloride, (iii) Flouride, (iv) Iron, (v) Hardness, (vi) Total Plate Count ,(vii) Electrici Conductivity, (viii) Sulfate, (ix) Nitrate , (x) TDS
c. (i) Colifrom, (ii) E coi lNote :- (i) The Rate quoted by the contractor deemed to be inclusive of the cost of transportation, cost of sample bottles as prescribed by the lab, cost of collection of samples from all the locations and submission of report.
(ii) The samples shall be collected during the distribution time, which shall be coordinated with the concerned JE.
(iii) The entire report should be submitted in the prescribed format indicating standard permissible values and test results. (iv) Testing of samples (a) to (f) for all the test will be measured as one job )
1
-
-
Supply only of Calcium Hypochlorite (Calcium based granular disinfectant for water treatment, more stale than chlorine gas and stronger than bleaching powder and sodium hypo chlorite) packing in 45 Kgs plastic drums, complete all as specified and directed by Engr-in-Charge.
200
-
-
Supply only Water Testing Kit for the estimation of Residual Chlorine,
6
-
-
Supply and fixing high quality chlorine pipe of 4-6 mm dia high pressure pipe for chlorine supply all as specified and directed.
25
-
-
S&F in repairs NRV valve of 15-20mm dia of chlorine dozing pump outgoing to main line all as speciifed and directed by Engr in charge.
2
-
-
M&L for taking out for repair f unserviceable Agitator Motor of dosing system and refixing after repair,capacity 120W single phase 220AC 50 Hz, 6 pole, 900rpm along with copper winding and replacement of unserviceable parts to make the moter serviceable all as specified and directed.
4
-
-
Taking out existing , supply and fixing of Injector Dosing Pump: Adjustable High Pressure 0-7 Kg/cm2 power input 220 V, 50 Hz 40 SPM 1/30 fractional horse power, Max ouput 0-10 Ltr/hr. Pump with PP Head with mandatory accessories (Antisyphone Valve Assy,Foot Valve Assy, Tubing (LDPE) 3 Mtrs.).
5
-
-
Taking out existing , supply and fixing ofService Dosing Tank Capacity 100 Ltr. (FRP dosing tank of 100 Ltr. Top dia 540 mm x Bottom dia 480 mm x Height 575 mm Consisting of water inlet line, Drain, Overflow Level gauge inspection port).
4
-
-
Supply , installation and testing of electricity based autometically digital water level indicator with sensor for OHT capacity 1.5 Lac Gallon /1.0 Lac Gallon /0.25 lac Gallon capacity, water level between 3.5 mtr to 4.50 mtr alongwith all conenceted items , digital meter fixed in Nearest concerned in Pump Room complete all as specified and directed by Engineer-in-Charge.
2
-
-
M&L for boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine for crossing of water pipe line GI/DI size upto 200mm dia as per specifed and directed by Engr-in-Charhe.
15
-
-
Material and labour for preparing old surfaces plastered and white wash 1st coat undecoratede surface and 2nd coat of old decorateed surface of valve chamber any size incl rubbing of internal surface by wire brush/scrubber,desilting of vale pit manually cleaning the internal area with brush, removing loose/deposited dirt etc, cleaning with water thorough as specifed and directed by Engr-in-Charge
50
-
-
Supply and fix in replacement for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters deep below normal ground level) with top edge of plate not less than 1.5 meter deep below normal ground level connected to galvanized earth strip of size 25 x 4 mm, 7.5m long means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of SSR part I connecting to earthing test point and testing on completion with and including PCC pit in mix 1:3:6 type c1 with RCC 1:2:4 type B-1, 40mm thick cover reinforced with 6mm dia MS bars 3 Nos both ways with lifting book made out of 6mm dia bar, watering arrangement with funnel and wire mesh and 20mm bore light grade GI watering pipe, common salt and charcoal filling, necessary excavation and earth work, complete all as directed.
11
-
-
Supply , fixing asnd testing of contractor capacity range 250A , 3P, 440V , Electric Pump rating 90 KW , Discharge 171 Cum/Hrs ( Model No LC1E250) Amps alongwith all connected items( lugs etc properly) as per specified and directed by Engr -in-Charge. Location :- For Akash Fire fighting Panel