Military Engineer Services Tender

If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.

Military Engineer Services - MES Tender

Works
Civil And Construction
Eprocure
Opening Date29 Oct 2024
Closing Soon23 Nov 2024
Tender Amount₹ 37,86,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Material and Labour for 15mm thick cement plastering in cm 1:6 on brick or concrete surfaces other than fair surface, finished the surfaces even and fair without using extra cement ; Complete all as specified and directed by Engineer-in-charge.

20

-

-

... More
Material and Labour for 10mm thick cement plastering in CM 1:3 on ceiling surfaces other than fair surface, finished the surfaces even and fair without using extra cement ; Complete all as specified and directed by Engineer-in-charge.

15

-

-

... More
Material and Labour for Rendering 15 mm thick on fair/unfair faces of brick work or concrete surfaces in CM 1:4 and to be finished even and smooth ( without using extra lime or cement) ; Complete all as specified and directed by Engineer-in-charge.

300

-

-

... More
Demolation of brick work built in cement mortar or cement lime mortar as cutting, opening of exsiting wall ; Complete all as specified and directed by Engineer-in-charge.

30

-

-

... More
Material and Labour for brick work with sub Class 'B' old size bricks, straight or curved on plan exceeding 6 Metre mean radius, built in cement mortar 1:6 ; Complete all as specified and directed by Engineer-in-charge.

30

-

-

... More
Material and Labour for applying plaster of paris putty of 1 mm thickness over plastered surface toprepare the surface even and smooth ; Complete all as specified and directed by Engineer-in-charge.

300

-

-

... More
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 5489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces.

300

-

-

... More
Material & Labour for complete removal of existing treatment from old existing wal and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 5489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. ; Complete all as specified and directed by Engineer-in-charge.

100

-

-

... More
Material and labour preparation of newly plastered surface of wall and applying three coats of white wash on ceiling surface ; Complete all as specified and directed by Engineer-in-charge.

15

-

-

... More
Demolition of Stone slabs and tiles of laid, beded and pointed of any mortar in any description or thickness in floors, aprons etc. ; Complete all as specified and directed by Engineer-in-charge.

3

-

-

... More
Material and Labour Granite (of any type) work (table rubbed and polished) 20mm thick in steps , jambs, pillars, window cills, cooking plateforms and like in cemnet mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including 15mm thick rendering in CM 1:4. ; Complete all as specified and directed by Engineer-in-charge.

30

-

-

... More
Supply and Fixing Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box,main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed ; Complete all as specified and directed by Engineer-in-charge.

12

-

-

... More
Supply and Fixing Floor door stopper of aluminium alloy body and tongue anodised with hard drawn steel spring fixed to door shutter of size 150mm. ; Complete all as specified and directed by Engineer-in-charge.

12

-

-

... More
Supply and Fixing Brass mortice lock, 4 levers, verticle type, size 100 mm, ; Complete all as specified and directed by Engineer-in-charge.

6

-

-

... More
Supply and Fixing Brass mortice lock, 2 levers, verticle type, size 100 mm, ; Complete all as specified and directed by Engineer-in-charge.

6

-

-

... More
Supply and Fixing 450mm long Brass handles, cast type ; Complete all as specified and directed by Engineer-in-charge.

24

-

-

... More
Dismantling floor, hearth or wall tiling including cement mortar bedding ( but not backing), removing serviceable tiles to store and rubbish off the premises. ; Complete all as specified and directed by Engineer-in-charge.

450

-

-

... More
Supply and Fixing Alivation tiles,/ glazed ceramic coloured tiles 450x300mmx6mm thick, etc. on vertical surfaces such as skirting , dados and risers to steps etc. set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match over and including 10mm thick rendering plaster in CM 1:4 on brick surface ; Complete all as specified and directed by Engineer-in-charge.

300

-

-

... More
Supply and Fixing non skid ceramic light coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or colour cement to match the colour of tiles over and including 15mm thick screed bed in CM 1:6 & ; Complete all as specified and directed by Engineer-in-charge.

140

-

-

... More
Supply and Fixing non skid ceramic light coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or colour cement to match the colour of tiles over and including 15mm thick screed bed in CM 1:6 & ; Complete all as specified and directed by Engineer-in-charge.

10

-

-

... More
Supply and Fixing powder coated aluminium frame for doors ,windows, ventilators with one or more rebates including joining cleats for fixing complete all as specified and directed by Engineer-In-Charge.( Min. thickness of powder coating 50 micron)

350

-

-

... More
Supply and Fixing Providing and fixing powder coated(Min thickness of powder coating shall be 50 micron) aluminum windows shutter of size min 18mmx50mm for sliding type windows of standard tubular sections of approved make having glazed panels or glazed and gauzed panels of appropriate size running on seperate tracks in the channel conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth,rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. All the panels shall be of appropriate size having overlaps as required and including all required beadings, clips, rollers, rubber gaskets, cleats, etc. complete and powder coating in approved shade and colour. Note:- Each panel shall be measured separetely. Glass pane and wire mesh shall be measured and paid separetely.

50

-

-

... More
Supply and Fixing Aluminium powder coated (of any colour) window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 Kilogram/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. ; Complete all as specified and directed by Engineer-in-charge. .(Min. thickness of powder coating 50 micron)

50

-

-

... More
Taking down aluminium door shutters of area exc 1 sqm but not exc 4 sqm each and replacement of necessary jointing cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc and refixing in the same opening including fixing to floor stopper or door closure ; Complete all as specified and directed by Engineer-in-charge.

6

-

-

... More
Supply and Fixing Sheet glass, 5.5mm thick ordinary quality, in squares,exceeding 0.50 sqm in each pane including rubber packing and aluminium beading with and incl solar control film 25 Micron reflective type sticked to glass panes as per instructions of manufacturer ; Complete all as specified and directed by Engineer-in-charge.

35

-

-

... More
Supply and Fixing 10mm thick PVC insulation panels with EPS stuck to 1mm printed PVC sheet suitably placed in aluminium door as per specification and drawing. ; Complete all as specified and directed by Engineer-in-charge.

25

-

-

... More
Material and Labour for Excavating in post holes( or similar holes) in soft/loose soil each n exc 0.5 cu.m. getting out, returning,filling in and ramming earth of broken rubble mixed with earth around , in layers not exceeding 25 cm, watring, and removing surplus soil to a distance n.exc 50 m and making good surface ; Complete all as specified and directed by Engineer-in-charge.

20

-

-

... More
Supply and Fixing mild steel Gde Fe-410-W as in roof trusses, (framed), trussed purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee,angle,channel or flat sections) including distance pieces , cleats etc. ; Complete all as specified and directed by Engineer-in-charge.

3500

-

-

... More
Supply and Fixing Fiber glass reinfored translucent 2 mm thick Pain sheet fixed wwith coach screw and washer in roof , wall ete ; Complete all as specified and directed by Engineer-in-charge.

150

-

-

... More
Supply and Fixing Anodised aluminium door shutters duly powder coated (minimum thickness of powder coating 50 micron) , aluminium section weighing not less than 0.55kg/m including necessary joining cleats, glazing clips, rubber/neoprene packing, handles 2 No's in each door, hinges, anodised aluminium snap beading, screws complete etc. ; Complete all as specified and directed by Engineer-in-charge.

8

-

-

... More
Supply and Fixing prepainted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength 550 MPAsheeting bend to a curv or shape as directed fixed with L-type or J-type or cranked hook bolts in lieu of screws with two corrugations side lap, fixed with coach screws and washers, in roofs, walls , cladding etc. ; with and including dismantling old unserviceable AC / GI ( corrugated, semicorrugated ,etc.) sheets in roof coverings or wall cladding . ; Complete all as specified and directed by Engineer-in-charge. Complete all as specified and directed by Engineer-in-charge.

420

-

-

... More
Supply and Fixing prepainted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength 550 MPA as in roof covering in roof covering incudingl ridge fixed with self tapping screws / L type or J type hook as specified with and including dismantling old unserviceable AC / GI ( corrugated, semicorrugated ,etc.) sheets in roof coverings or wall cladding . ; Complete all as specified and directed by Engineer-in-charge. Complete all as specified and directed by Engineer-in-charge.

100

-

-

... More
Supply and Fixing for mild steel work as in post and struts including embeding in concrete and screwing etc ,wind tie of roof including securing with bolts ; Complete all as specified and directed by Engineer-in-charge.

2700

-

-

... More
Material and Labour for PCC 1:3:6 type C-2 ( using 40mm graded crushed stone aggregate) as in foundation, filling and mass concrete of post holes. ; Complete all as specified and directed by Engineer-in-charge.

7

-

-

... More
Material and Labour for preparing new steel surfaces and applying two coats of synthetic enamel pait over a coat of red oxide ; Complete all as specified and directed by Engineer-in-charge.

125

-

-

... More
Material and Labour for PCC type D 2 (1:4:8) 40mm graded aggregate ; Complete all as specified and directed by Engineer-in-charge.

15

-

-

... More
Material and labour for machine pressed coloured chequered cement concrete tile ISI Marked of size 30cm x30cmx22-25mm thick over and including 15mm thick cement screed in CM 1:6 set and jointed in neat cement slurry and pointed with white cement mixed with pigment to match the colour of tiles ; Complete all as specified and directed by Engineer-in-charge.

150

-

-

... More
Material and Labour for Machine pressed coloured precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 grade with grey cement and pigments over and including 50mm thick sand cushioning ; Complete all as specified and directed by Engineer-in-charge.

150

-

-

... More
Demolition of cement concrete (un-reinforced)in ground floor and paving n. exc 15 cm thick below or above ground level & dispose off debris upto a distance n. exc. 50 mtrs where directed ; Complete all as specified and directed by Engineer-in-charge.

15

-

-

... More
Demolation of RCC in any position not otherwise specifically provided ; Complete all as specified and directed by Engineer-in-charge.

10

-

-

... More
Material and Labour for RCC (Design Mix) M-25 (20mm graded aggregate) in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete. ; Complete all as specified and directed by Engineer-in-charge.

4

-

-

... More
Material and Labour for RCC(Design Mix) M-25 (20mm graded aggregate) in column, pillars, piers, post and struts. ; Complete all as specified and directed by Engineer-in-charge.

4.5

-

-

... More
Material and Labour for RCC (Design Mix) M-25 (20 mm graded aggregate) as in Beams, canatilivers, bressummers, lintels over 1.5m span etc ; Complete all as specified and directed by Engineer-in-charge.

6

-

-

... More
Material and Labour for RCC(Design Mix) M-25 (20mm graded aggregate) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like. ; Complete all as specified and directed by Engineer-in-charge.

8

-

-

... More
Supply and Fixing Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of rough finished surfaces of concrete in foundation and plinth beams; and similar work; vertical or to batter ; Complete all as specified and directed by Engineer-in-charge.

75

-

-

... More
Supply and Fixing Formwork to sides of pillars, posts, struts, piers, columns and stanchions of rough finished surfaces of concrete. ; Complete all as specified and directed by Engineer-in-charge.

80

-

-

... More
Supply and Fixing Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) of fair finished surfaces of concrete. ; Complete all as specified and directed by Engineer-in-charge.

65

-

-

... More
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide. ; Complete all as specified and directed by Engineer-in-charge.

50

-

-

... More
Material and Labour for TMT Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips. ; Complete all as specified and directed by Engineer-in-charge.

1850

-

-

... More
Material and Labour for TMT Mild steel bars 6 to 8 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips. ; Complete all as specified and directed by Engineer-in-charge.

350

-

-

... More
All as per item No 53 but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders.; Complete all as specified and directed by Engineer-in-charge.

240

-

-

... More
Material and Labour for Preparation of New or Previously untreated surfaces of any description , over 10 cm in width or girth, not otherwise described and applying two coat of synthetic enamel paint over a coat of Red oxide primer. ; Complete all as specified and directed by Engineer-in-charge.

100

-

-

... More
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials and making good disturbed surfaces of walls, floors, etc. ; Complete all as specified and directed by Engineer-in-charge.

54

-

-

... More
Material and Labour for point wiring complete with 1.5 sqmm single core PVC insulated sheathed multi-stranded, copper conductor FRLS grade cable of 1100 volts grade conforming to IS:694 drawn through and including non metalic rigid PVC conduit, medium grade, ISI marked, not less than 20mm bore with conduit accessories concealed on wall and ceiling/roof etc, with provn for fixing modular metal flush boxes not less than 1.0 mm thick of suitable modules, concealed in walls with modular white plated cover as top cover fixed with screws for housing switches, socket outlets, fan regulators etc, including provn of 1.5 sqmm nominal cross sectional area, PVC insulated, FRLS, sheathed, 1100 volt grade,multistranded single core green colour copper conductor for earth continuity connected to earth dolly ; Complete all as specified and directed by Engineer-in-charge. (One light point controlled by one switch) NOTE for Sr Item No 57 to 61 : (i) Modular metal flush boxes concealed in wall with suitable cover plate for mounting switch, sockets, regulator etc. and cost of cutting chases & making good as existing to disturbed surface with cement mortar, if required any shall be deemed to included in the quoted rates. (ii) Modular fittings/fixtures such as switch, socket, regulator, etc., shall be measured and paid separately as under relevant item.

30

-

-

... More
Material and Labour for point wiring complete with 1.5 sqmm single core PVC insulated sheathed multi-stranded, copper conductor FRLS grade cable of 1100 volts grade conforming to IS:694 drawn through and including non metalic rigid PVC conduit, medium grade, ISI marked, not less than 20mm bore with conduit accessories concealed on wall and ceiling/roof etc, with provn for fixing modular metal flush boxes not less than 1.0 mm thick of suitable modules, concealed in walls with modular white plated cover as top cover fixed with screws for housing switches, socket outlets, fan regulators etc, including provn of 1.5 sqmm nominal cross sectional area, PVC insulated, FRLS, sheathed, 1100 volt grade,multistranded single core green colour copper conductor for earth continuity connected to earth dolly ; Complete all as specified and directed by Engineer-in-charge. ( One Fan point controlled by one switch & regulator)

6

-

-

... More
Material and Labour for point wiring complete with 1.5 sqmm single core PVC insulated sheathed multi-stranded, copper conductor FRLS grade cable of 1100 volts grade conforming to IS:694 drawn through and including non metalic rigid PVC conduit, medium grade, ISI marked, not less than 20mm bore with conduit accessories concealed on wall and ceiling/roof etc, with provn for fixing modular metal flush boxes not less than 1.0 mm thick of suitable modules, concealed in walls with modular white plated cover as top cover fixed with screws for housing switches, socket outlets, fan regulators etc, including provn of 1.5 sqmm nominal cross sectional area, PVC insulated, FRLS, sheathed, 1100 volt grade,multistranded single core green colour copper conductor for earth continuity connected to earth dolly ; Complete all as specified and directed by Engineer-in-charge. ( One 5 Amps outlet point on same board with other switches/sockets)

3

-

-

... More
Material and Labour for point wiring complete with 1.5 sqmm single core PVC insulated sheathed multi-stranded, copper conductor FRLS grade cable of 1100 volts grade conforming to IS:694 drawn through and including non metalic rigid PVC conduit, medium grade, ISI marked, not less than 20mm bore with conduit accessories concealed on wall and ceiling/roof etc, with provn for fixing modular metal flush boxes not less than 1.0 mm thick of suitable modules, concealed in walls with modular white plated cover as top cover fixed with screws for housing switches, socket outlets, fan regulators etc, including provn of 1.5 sqmm nominal cross sectional area, PVC insulated, FRLS, sheathed, 1100 volt grade,multistranded single core green colour copper conductor for earth continuity connected to earth dolly ; Complete all as specified and directed by Engineer-in-charge. ( One 3 pin 5 Amps socket outlet on independent board.)

10

-

-

... More
All as per ser item No. 60 here in above but point wiring with 2.5 Sqmm FRLS cable and 2.5 sqmm cable earth continuity wire for one 3 pin socket outlet,15 Amps on independent board. ; Complete all as specified and directed by Engineer-in-charge.

5

-

-

... More
Supply and Fixing modular switch 1 way 6A, 240 volts, 1 module ; Complete all as specified and directed by Engineer-in-charge.

49

-

-

... More
Supply and Fixing modular switch 1 way 16A, 240 volts, 1 module ; Complete all as specified and directed by Engineer-in-charge.

5

-

-

... More
Supply and Fixing modular socket, 6A, 240 volts, 2/3 pin combined 2 module, flush type ; Complete all as specified and directed by Engineer-in-charge.

13

-

-

... More
Supply and Fixing modular socket, 6A/16A, 240 volts, 2/3 pin combined 2 module flush type ; Complete all as specified and directed by Engineer-in-charge.

5

-

-

... More
Supply and Fixing ceiling rose surface PVC/Polycarbonate, isolated body with face Bakelite 65x50 mm three terminal ; Complete all as specified and directed by Engineer-in-charge.

34

-

-

... More
Supply and Fixing modular fan step regulator, 2 module, 240 Volts, 50 Hz, suitable for ceiling fan 1200 mm sweep ; Complete all as specified and directed by Engineer-in-charge.

6

-

-

... More
Supply and Fixing Lamp holder angular type, PVC/Polycarbonate type with back plate suitable for batten fittings including 10cm x 10cm presto plastic board for resting to holder including Supply and Fixing 01 x 10/12 watts LED lamp, 230 volts ; Complete all as specified and directed by Engineer-in-charge.

2

-

-

... More
Supply and Fixing LED lights fitting 1x 20W, 220V, AC, 5700K, decorative box type with driver, double sided connection, CRI 80, PF95%, THD10%, Lumen2100 lm including LED tube light of make: Havells or equivalent in Philips/Crompton, connecting up with 3 core flexible copper conductor cable (1.0 mm² size/core) from ceiling rose ; Complete all as specified and directed by Engineer-in-charge.

20

-

-

... More
Supply and Fixing Wall mounted, indoor, Mirror Light LED with aluminium die cast, suitable for and including 10 watt 6000K, WH LED light, prewired incl connecting up ; Complete all as specified and directed by Engineer-in-charge.

2

-

-

... More
Supply and Fixing Dusk & dawn roadway luminaries 45 Watt, 230 V AC, 5700K outdoor type with epoxy black powder coated sheet of make: Havells or equivalent make of Philips/Crompton, high pressure die-cast aluminum hosing and heat resistant complete with impact and corrosion resistant including thermal management in multiple optics, PF95%, THD10%, Lumen4500 lm with IP 65/66 protection complete incl connecting wire with flexible PVC insulated copper cables from ceiling rose to fitting including driver, lamp bracket made of 32mm bore galvanised iron light grade pipe made to shape having overall length not exceeding 1.5 mtr, through mild steel clamp of 25mm width and four Nos. nuts, bolts & washers of 12mm dia, 100mm long fixed to wall with all other fittings ; Complete all as specified and directed by Engineer-in-charge.

6

-

-

... More
Taking down carefully existing serviceable Ceiling fan, ceiling cable end, etc., removing the fan for keeping in safe custody, hanging the ceiling fan with down rod after rewiring including clamps, hooks, holdfasteners etc and connecting up, including making electric connection from ceiling rose to fan ; Complete all as specified and directed by Engineer-in-charge.

6

-

-

... More
Material and Labour for loadline distribution board, vertical, made out of sheet metal enclosure (CRCA sheet) dust and vermin proof, double door, VTPN 4 way, 415 volts grade with insulated rated bus bar assembly with isolated neutral bar,door earthing, earth bar IP- 43 protection with poly urithene (PU) gasketing, IK-08 Mechanical impact resistance, door earthing flush to wall, including testing suitable for fixing MCCB, MCB TPN/TP/SPN/SP etc, complete incl taking down old unsv one any type and any size from site ; Complete all as specified and directed by Engineer-in-charge. NOTE: (i) MCB DB & MCBs, MCCB should be of same make as mentioned above. (ii) Necessary blank plates if required any to cover the blank MCB's place in DB and the rate shall be deemed to included in the quoted rates.

1

-

-

... More
Supply and Fixing MCCB triple pole and neutral (four pole) 63 Amps, 415 volts, 50 Hz, having thermal setting range 70% to 100% and adjustable magnetic setting and breaking capacity 16 KA including making incoming and outgoing connections complete incl taking down old unsv one any type and any size from site ; Complete all as specified and directed by Engineer-in-charge.

1

-

-

... More
Supply and Fixing MCB of SP 5 to 32 Amps current carrying capacity, 240V, 10KA 'C' curve, ISI marked, fixed in the MCB DB complete conforming to IS/IEC-60898-1 2002 with connection testing and commissioning including taking down old unsv one any type and any size from site ; Complete all as specified and directed by Engineer-in-charge.

12

-

-

... More
Material and Labour for Earthing complete in replacement with galvanised iron mild steel earth plate electrode 60 cm x 60 cm x 6.3mm thick burried directly in ground vertically to a depth not less than 2.25 m below ground level with top edge of earth plate at a depth of not less than 1.5 m below normal ground level, connected to glavanised earth lead of GI wire of size 4mm dia by means of GI Bolts, Nuts, check nuts & washers and other end of the earth wire connected to earthing test point and protected by galvanised iron pipe light grade 25mm dia from earth plate to Panel/DBs and water pipe 20mm dia GI medium grade from top of the earth electrode raised upto a level of 50cm above ground level, MS funnel with wire mesh embeded in earthing pit of size 30x30x30cm in PCC (1:3:6) type C-1 incl exposed surfaces smoth finished with 15mm thick cement mortar (1:6), RCC pre-cast (1:2:4 type B-1) cover slab of 40mm thick with 2 Nos. MS handles of 12mm dia suitable for carrying of pit cover, Angle iron frame made out of 40x40x4mm angle iron for 30x30mm PCC pit for holding the pit cover including providing charcoal or coke and salt in alternative layers of 15 cm including necessary earth work in soft/loose soil, returning, refilling and removing of surplus soil to a distance n. exc. 50 mtr testing complete all as shown in electrical plate No-3 of MES Schedule Part-I of SSR-2009 ; Complete all as specified and directed by Engineer-in-charge. NOTE: (a) Cost of excavation, earth work, watering pipe, test point, MS Funnel with wire mesh and PCC pit with cover will be deemed to be included in the quoted rate. No extra cost shall be paid to the contractor against these items. (b) On testing after completion of job, if desired earth resistance is not obtained, the earthing shall be redone by the contractor & no extra cost will be given to the contractor.

2

-

-

... More
Supply and Laying in trenches/drawn through pipes or in road crossings/paths/drains/ ducts/floors/along poles/equipments etc., of LT cable under ground, heavy duty, armoured, XLPE insulated with stranded aluminium conductor, 1100 Volts grade of 16 Sqmm 4 core cross sectional areas including connecting up using suitable size aluminium lugs testing and commissioning ; Complete all as specified and directed by Engineer-in-charge. NOTE: Excavation, earthwork, cable protection pipe shall be measured and paid separately

30

-

-

... More
Supply & laying double wall corrugated (DWC) high density poly ethylene (HDPE) of size 40mm dia including all necessary fittings, PN-4 rating, pressure 6 Kgf/cm², conforming to IS-16205 (Part-24) with high ring stiffness & cursh resistance capacity, etc., laid in trench for protection of submersible flat cable ; Complete all as specified and directed by Engineer-in-charge.

25

-

-

... More
Excavating in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for foundation for erection of poles, stays, laying cables, stays etc and getting out in soft/loose soil and in road cutting ; Complete all as specified and directed by Engineer-in-charge.

4

-

-

... More
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm in soft/loose soil ; Complete all as specified and directed by Engineer-in-charge.

3.5

-

-

... More
Removing excavated material/surplus soil not exceeding 50 meters and depositing where directed at a level not exceeding 1.5 meter above starting point ; Complete all as specified and directed by Engineer-in-charge.

0.5

-

-

... More
A

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.