Military Engineer Services Tender

If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date31 Aug 2024
Closing Date1 Oct 2024
Tender Amount₹ 25,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Dismantling Radiator assy complete including cleaning, washing with cleaning equipment and refitting the same complete all as specified and directed

1

-

-

... More
Servicing of DG set 160 KVA (MES No- 263/6122/DG/24) including replacement of following parts, alignment of Alternator, Minor repair and complete checking of fuel Pump after necessary inspection of DG set complete all as specified and directed. Make of DG Set- Mahindra & Mahindra. (spares, lube oil and coolent shall be measured and paid separately under respective items of BoQ here-in-after)

1

-

-

... More
Supply only Filter kit comprising of Air,Fuel and oil filters to be incorporated in Srl Item No 2.00 above all as specified and directed.

2

-

-

... More
Supply only Fan Belt as per sample to be incorporated in Srl Item No 2.00 above all as specified and directed.

1

-

-

... More
Dismantling Radiator assy complete including cleaning, washing with cleaning equipment and refitting the same complete all as specified and directed

1

-

-

... More
Servicing of DG set 125 KVA (MES No- i- 263/6004/DG,AL/02, II-263/6033/DG/09, III- 263/6074/DG/14) including replacement of following parts, alignment of Alternator, Minor repair and complete checking of fuel Pump after necessary inspection of DG set complete all as specified and directed. Make of DG Set- Kirloskar/ Cummins/ Ashoka Layland. ( spares, lube oil and coolent shall be measured and paid separately under respective items of BoQ here-in-after):-

3

-

-

... More
Supply only Filter kit comprising of Air,Fuel and oil filters to be incorporated in Srl Item No 3.00 above all as specified and directed.

3

-

-

... More
Supply only Fan Belt as per sample to be incorporated in Srl Item No 3.00 above all as specified and as directed.

3

-

-

... More
Dismantling Radiator assy complete including cleaning, washing with cleaning equipment and refitting the same complete all as specified and directed

3

-

-

... More
Servicing of DG set 75 KVA (MES No- 164090) Make-Kirloskar including replacement of following parts alignment of Alternator, minor repair and complete checking of fuel pump after necessary inspection of DG set complete all as specified and directed (spares shall be measured and paid separately under respective items of BoQ here-in-after)

1

-

-

... More
Supply only Filter kit comprising of Air, Fuel and oil filters to be incorporated in Srl Item No 4.00 above all as specified and directed.

1

-

-

... More
Supply only Fan Belt as per sample to be incorporated in Srl Item No 4.00 above all as specified and directed.

1

-

-

... More
Dismantling Radiator assy complete including cleaning, washing with cleaning equipment and refitting the same complete all as specified and directed

1

-

-

... More
Servicing of DG set 40 to 63 KVA (MES No- i- 263/6005/DG,AL/05, ii-263/6098/DG/16, iii- 715/6010/DG/06, iv- 261839W, NYA ) Make- Cummins/ Kirloskar) including replacement of following parts alignment of Alternator, Minor repair and complete checking of fuel Pump after necessary inspection of DG set complete all as specified and directed (spares shall be measured and paid separately under respective items of BoQ here-in-after):-

4

-

-

... More
Supply only Filter kit comprising of Air,Fuel and oil filters to be incorporated in Srl Item No 5.00 above all as specified and directed.

4

-

-

... More
Supply only Fan Belt as per sample to be incorporated in Srl Item No 5.00 above all as specified and directed.

4

-

-

... More
Dismantling Radiator assy complete including cleaning, washing with cleaning equipment and refitting the same complete all as specified and directed.

4

-

-

... More
Servicing of DG set 25 KVA (MES No- 263/6043/DG/AL/06, 02 Nos NYA) (Make- Kirloskar) including replacement of following parts alignment of Alternator, minor work and complete checking of fuel pump after necessary inspection of DG set complete all as specified and directed (spares shall be measured and paid separately under respective items of BoQ here-in-after):-

2

-

-

... More
Diesel filter kit to be incorporated in Srl Item No 6.00 above. all as specified and as directed.

2

-

-

... More
Oil filter kit to be incorporated in Srl Item No 6.00 above all as specified and directed.

2

-

-

... More
Fan belt as per sample to be incorporated in Srl Item No 6.00 above all as specified and directed.

2

-

-

... More
Dismantling Self Starter assy of DG of capacity 25 kVA including necessary repairs/ calibration and reassembling the same after repair all as specified and directed.

1

-

-

... More
Supply & filling and topping up Engine oil of suitable grade 15W30 for above mentioned different capacity DG set all as specified and directed.

140

-

-

... More
Supply & replace Coolant for Radiator for above mentioned different capacity DG set all as specified and directed.

100

-

-

... More
Supply & fix as in replacement on load change over switch side handle operated 415v 50hz 4 pole of capacity 63Amp all as specified and directed..

1

-

-

... More
Supply & fix as in replacement on load change over switch side handle operated 415v 50hz 4 pole of capacity 100Amp all as specified and directed..

2

-

-

... More
Supply & fix as in replacement on load change over switch side handle operated 415v 50hz 4 pole of capacity 125Amp all as specified and directed.

1

-

-

... More
Supply & fix as in replacement on load change over switch side handle operated 415v 50hz 4 pole of capacity 200Amp all as specified and directed..

1

-

-

... More
Supply & fix as in replacement on load change over switch side handle operated 415v 50hz 4 pole of capacity 400Amp all as specified and directed..

1

-

-

... More
Supply and replace power contactor AC 415 volt, operating coil -230 volts, four pole type MCX 31 and 40 including auxiliary contacts 1NO+1NC suitable for AMF panel complete all as specified and directed .

2

-

-

... More
Supply and replace power contactor AC 415 volt, operating coil -230 volts, four pole type MCX 33 including auxiliary contacts 1NO+1NC suitable for AMF panel complete all as specified and directed .

2

-

-

... More
Supply and replacement of AMF panel auto start relay/ voltage monitering relay as per existing and with copper conductoer wiring of AMF panel with suitable size wire complete all as sample of existing relay complete all as specified and directed .

2

-

-

... More
Labour only for complete calibration of AMF Panel of capacity 40 to 75 KVA, checking all functioning state of components, cleaning of contactor links with suitable cleaning material with and including minor repairs, insulation, tightening of control wiring cables,copper lugs complete all as specified and directed

2

-

-

... More
Material and labour for painting by using spray painting method for DG set canopy/ complete body/ LT panel board (After removing incoming/out going electrical connection and refixing the same) with two coats of superior quality synthetic enamel paint after cleaning of existing surface, removing rust including marking of incoming/ outgoing feeder with letters, MES/ SM Nos complete and all as specified and directed.

2

-

-

... More
Supply & install in repair Lead Acid Battery 12 V 180 AH complete all as specified and directed.

2

-

-

... More
Supply & install in repair Lead Acid Battery 12 V 150 AH complete all as specified and directed.

2

-

-

... More
Supply & install in replacement of Battery Charging unit 24V, 250 kVA DG set complete all as specified as per existing cat part/ sample.

1

-

-

... More
Supply & install in replacement of Battery Charging unit 24 V, 160 kVA DG set complete all as specified as per existing cat part/sample.

1

-

-

... More
Supply & install in replacement of Battery Charging unit 24 V, 125kVA DG set complete all as specified as per existing cat part/sample.

2

-

-

... More
Supply & install in replacement of Battery Charging unit 12 V, 75 kVA DG set complete all as specified as per existing cat part/sample.

1

-

-

... More
Supply & install in replacement of Battery Charging unit 12V, 40kVA DG set complete all as specified as per existing cat part/sample.

1

-

-

... More
Supply & install in replacement of Inverter/ UPS 1500 VA complete all as specified and directed.

1

-

-

... More
Supply and fixing in replacement of digital Voltage regulator unit of AMFpanel of DG Set 25 kVA to 125 KVA capacity as per existing type and model all as specified and directed.

2

-

-

... More
Supply and fixing in replacement of digital Voltage regulator unit of AMFpanel of DG Set 160kVA to 250 KVA capacity as per existing type and model all as specified and directed.

2

-

-

... More
Supply and replacing complete hose pipe set with clamps for DG sets of capacity 25 KVA to 100 KVA as per existing type and size all as specified and directed.

3

-

-

... More
Supply and replacing complete hose pipe set with clamps for DG sets of capacity 125 KVA to 250 KVA as per existing type and size all as specified and directed.

3

-

-

... More
Supply and fixing inreplacement exhaust assembling for 25 kVA DG set as per existing type and model all as specified and directed.

1

-

-

... More
Supply and fixing in replacement exhaust assembling for 125 kVA to 250kVA DG set as per existing type and model all as specified and directed.

1

-

-

... More
Material & Labour Dismantling the alternator of DG set of capacity 25 KVA to 75 kVA from its base by using chain and pulley after removing the coupling with the engine, removing all nut, bolt with washer and all electrical connections of the alternator, shifting the alternator to work shop by crane and vehicle, opening into parts, checking all winding like main starter/ rotor winding, exciter starter/ rotor winding. Rewinding the main rotor and exciter rotor by using the "F" class insulation and existing gauge and type of magnet wire that was on the original motor, varnishing, heating, drying, greasing the bearings including replacement of unserviceable bearings, Re-fixing the complete including connection to the terminal box of the alternator at work shop and shifting the same to the site, Fixing the alternator to its base carefully by using chain and pulley, connecting it with existing engine including checking the alignment of alternator with the engine, connecting all electrical connections of the alternator and testing the DG set on "OFF/FULL LOAD", matching to the existing range of RPM of the engine, out put voltage 415 volt and testing all as specified and directed.

1

-

-

... More
Material & Labour Dismantling the alternator of DG set of capacity 125 KVA to 250 kVA from its base by using chain and pulley after removing the coupling with the engine, removing all nut, bolt with washer and all electrical connections of the alternator, shifting the alternator to work shop by crane and vehicle, opening into parts, checking all winding like main starter/ rotor winding, exciter starter/ rotor winding. Rewinding the main rotor and exciter rotor by using the "F" class insulation and existing gauge and type of magnet wire that was on the original motor, varnishing, heating, drying, greasing the bearings including replacement of unserviceable bearings, Re-fixing the complete including connection to the terminal box of the alternator at work shop and shifting the same to the site, Fixing the alternator to its base carefully by using chain and pulley, connecting it with existing engine including checking the alignment of alternator with the engine, connecting all electrical connections of the alternator and testing the DG set on "OFF/FULL LOAD", matching to the existing range of RPM of the engine, out put voltage 415 volt and testing all as specified and directed.

1

-

-

... More
Taking down self starter assembly 12 volt of DG set 25kVA to 100kVA from the existing position, opening in to parts, sort out the unserviceable items like carbon brush, pinion etc. and replace the same with new one including rewinding of field coils, re-assembling and re-fixing the same in its original position including to and from conveyance charges to work shop and testing and all as specified and directed.

3

-

-

... More
Taking down self starter assembly 24 volt of DG set 125kVA to 250kVA from the existing position, opening in to parts, sort out the unserviceable items like carbon brush, pinion etc. and replace the same with new one including rewinding of field coils, re-assembling and re-fixing the same in its original position including to and from conveyance charges to work shop and testing and all as specified and directed.

3

-

-

... More
Taking down water pump assembly from the existing position, opening into parts overhauling the same with replacement of water pump repair kit, ball bearing (1No) water pump, gasket seal, oil seal and re-assembling and re-fixing on the base for the capacity 25kVA to 100 KVA DG sets and all as per the direction of the engr-in-charge.

2

-

-

... More
Taking down water pump assembly from the existing position, opening into parts overhauling the same with replacement of water pump repair kit, ball bearing (1No), water pump, gasket seal, oil seal and re-assembling and re-fixing on the base for the capacity 125kVA to 250 KVA DG sets and all as specified and directed.

2

-

-

... More
Taking down the Dynamo 12/24 Volts from the existing position, shifting to the work shop and back , opening into parts, cleaning to sort out the unserviceable parts, replace by new one, rewinding and varnishing, heating of coil, reassembling and re-fixing to its base including to and from conveyance charges for work shop to the site for any capacity of DG and all as specified and directed..

2

-

-

... More
Dismantling fuel injection pump (FIP) of DG set capacity 25 to 250 KVA carefully, opening in to parts, for maintenance, servicing, tuning by overhauling and calibration up to 6 cylinders, adjustment of nozzle pressure and other controls, replacement of unserviceable spares, re-fixing the FIP on its original position including to and from conveyance charges to the work shop and all as specified and directed.

2

-

-

... More
Supply & Fix in repair CONTROL & AMF PANEL BOARD for 45 KVA DG Set all as specified and directed. Note (i) The control panel is manufactured with 16/18 guage CRCA sheet and is powder coated for a weather proof and long lasting finish. The control panel/AMF panel consists of Microprocessor based DES 9 electronics controller, MCCBs of suitable rating, Key switche, Push button (Starter), LED battery charging alternator fail indication, current transformer, instrument fuses, Sound proof and weather proof encosure with safety features. (ii) KWH meter 3 phase, 415 volt and 63 Amp capacity - 01 Nos (iii) Volt meter 0-50 volt with rotary selector switch 3 ways flush typs - 01 Nos (iv) Ampere meter 0-100 flush type with rotary switch 3 ways - 01 Nos (v) Indicating lamp RYB - 03 Nos (vi) The AMF panel consist Key switcyhes/Auto start Generator set controller, Multy functional meter displaying Current and Voltages.

1

-

-

... More
Supply & Fixing LED flood Light comprising of aluminium die cast body housing, IP 66 high bay light with high power LED's as light source suitable for architectural features or retail space of capacity 120 Watts (not less than 100 lumen/watt output) including bracket (as per manufacturer's instructions) for mounting flood lights with suitable clamps and nut and bolts and washers etc including connecting from pole/ box to street light all as specified.

40

-

-

... More
Supply & Fixing LED security Light comprising of aluminium die cast body housing, IP 66 with high power LED's as light source suitable for roads, play ground etc of capacity 120 Watts with lance (not less than 100 lumen/ watt output) including nut and bolts and washers etc connecting from pole/ box to street light all as specified.

50

-

-

... More
Supply & Fixing LED security Light comprising of aluminium die cast body housing, IP 66 with high power LED's as light source suitable for roads,play ground etc of capacity 90 Watts with lance (not less than 100 lumen/ watt output) including nut and bolts and washers etc connecting from pole/ box to street light all as specified.

70

-

-

... More
Supply & Fixing LED security Light comprising of aluminium die cast body housing,IP 66 with high power LED's as light source suitable for roads,play ground etc of capacity 60 Watts with lance (not less than 100 lumen/watt output) including nut and bolts and washers etc connecting from pole/ box to street light all as specified.

100

-

-

... More
Supply & Fixing LED security Light comprising of aluminium die cast body housing, IP 66 with high power LED's as light source suitable for roads,play ground etc of capacity 45 Watts with lance (not less than 100 lumen/watt output) including nut and bolts and washers etc connecting from pole/ box to street light all as specified.

40

-

-

... More
Supply & Fixing new generation LED post top lantern energy saving, environmental friendly, long life asethetically designed with symetrical light distribution, spun aluminium landscape lumanier with high power LED's as light source of capacity 20 Watts (not less than 100 lumen/watt output) suitable to mount on min 32 mm dia GI tube as post including three core copper cable of size 2.5 sqmm with suitable length all as specified and directed..

20

-

-

... More
Supply and fixing of LED Post top globe star made up of unbreakable poly carbonate suitable for mounting on post 40 mm dia GI tube, including LED lamp 9 watts including holder all as specified

20

-

-

... More
Supply and laying in trenches through pipe under culvert or in air cable XLPE insulated PVC sheathed heavy duty 1100 volts grade stranded aluminum conductor size 10 Sqmm 4 core complete all as specified and directed. (Note –necessary excavation and returning filling, sand cushioning and bricks protection shall be measured and paid separately under respective item of BoQ

800

-

-

... More
Supply and laying in trenches through pipe under culvert or in air cable XLPE insulated PVC sheathed heavy duty 1100 volts grade stranded aluminum conductor size 16 Sqmm 4 core complete specified and directed. (Note –necessary excavation and returning filling, sand cushioning and bricks protection shall be measured and paid separately under respective item of BoQ

400

-

-

... More
Supply and laying in trenches through pipe under culvert or in air cable XLPE insulated PVC sheathed heavy duty 1100 volts grade stranded aluminum conductor size 10 Sqmm 2 core complete specified and directed. (Note –necessary excavation and returning filling, sand cushioning and bricks protection shall be measured and paid separately under respective item of BoQ

350

-

-

... More
Supply and erecting in true vertical position of steel tublar pole swan neck type 9 Mtrs long complete with cast iron base plate finial taper plug bolt nuts and screws as as specified and of type 410 SP-31 conforming to relevent IS including two coats of aluminium paint over one coat of red oxide primer to the full length of the pole and also two coats of bituminus paint inside & outside of bottom portion upto 1.5 mtrs length and provide circular bend 32 mm dia 1 Nos of length 2 mtrs duly fixed with necessary clamp for mounting LED security light all as specified and directed. Note:- Excavation and PCC shall be measured and paid separetaly, removing of broken pole from site and making disturbed surface good without any extra cost is included in the quoted rate.

8

-

-

... More
Supply and erecting in true vertical position of steel tublar pole 9 Mtrs long complete with cast iron base plate finial taper plug bolt nuts and screws as as specified and of type 410 SP-31 conforming to relevent IS including two coats of aluminium paint over one coat of red oxide primer to the full length of the pole and also two coats of bituminus paint inside & outside of bottom portion upto 1.5 mtrs length and provide circular bend 32 mm dia 1 Nos of length 2 mtrs duly fixed with necessary clamp for mounting LED security light all as specified and directed. Note:- Excavation and PCC shall be measured and paid separetaly, removing of broken pole from site and making disturbed surface good without any extra cost is included in the quoted rate. .

12

-

-

... More
Supply & erection in replacement new Pre stressed concrete pole, 9.0 Mtr Long 102mm x 172 mm at top and 102mm x 279 at bottom, class 10 including writing pole numbers and making five numbers black & yellow strips of 30 cm each upto 1.5 mtr height above the coping, including making connection of conductor as per existing all as specified and directed. Note :- Earth work, PCC for foundation and coping work shall be measured and paid for separately, removing of broken pole from site and making disturbed surface good without any extra cost is included in the quoted rate.

5

-

-

... More
Supplying and laying in replacement synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, (superceding IS 5424) suitable for electrical shock safety of sizes 2m x 1m, all as specified and directed

6

-

-

... More
Supply and fixing in repair of automatic street light control switch single phase 5-8 KW 40 Amps using infrared sensor based nature switch for automatic switching of street lights. Nature switch operation should be based on Natural light lux level. The sensor along with suitable power contactors and incoming out going MCBs should be enclosed in pole/ wall mounted thermo plastic polycarbonate enclosure conforming to IP 66 protection class 2 all as specified and directed

5

-

-

... More
Material and labour in replacement Earthing complete with Galvanized steel earth plate 600 x 600 x 6.0 mm buried directly in ground (earth pit not less then 2.25 Mtr deep below ground level) with top edge of the plate not less then 1.5 Mtr below normal ground level connected to GI earth lead of 4 mm as earth lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel incl excavation and earth work, GI pipe light grade 25mm bore for protection of GI wire /strip from earth electrode supplying and lying charcoal dust, common salt, PCC 1:3:6 type CI (using 20 mm graded crushed stone aggregate) as in chamber and MS angle iron frame 40 x 40 x 3mm and RCC cover 40 mm thick 1:2:4 type B1 (using 20 mm graded crushed stone aggregate) reinforced with 8 mm dia. TMT bars @ 75mm c/c both ways with MS handle 12 mm dia, PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering all as shown in electrical plate No. 3 of SSR Part I of 2009 and connected to earth test point incl testing complete all as specified and directed.

10

-

-

... More
Material & Labour for PCC 1:4:8 type D-2 using 40 mm graded broken stone aggregate as in mass concrete in foundations etc. complete all as specified and directed.

14

-

-

... More
Material & Labour for PCC 1:2:4 type B-1 using 20 mm graded broken stone aggregate as in copping/form work/plinth etc complete all as specified and directed .

3

-

-

... More
Suppy and fix Rigid non-metallic PVC conduit 20 mm dia exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc.complete all as specified and directed .

250

-

-

... More
Supply & fixing of sheet metal (MS) 1.8 mm thick bus bar box single door, outdoor type weather proof, size 300x300x200mm mounted on ground with iron angles (25x25x4mm) having alluminium bus bar 4 nos, rated 100amp all as specified & directed

10

-

-

... More
Supply and fixing in replacement street light junction box of size 250 mm x 200 mm x 100 mm, made out of hot press moulded SMC with weather proof hinged door including self locking arrangement, out door type weather and vermin proof complete comprising of insulated / high quality PVC sleeves aluminium bus bar of capacity 63 Amps 04 Nos (three phase RBY and black for neutral) including 25 x 3 mm flat iron mounted on insulators, having arrangement of connecting incoming and outgoing cables complete all as specified and directed.

30

-

-

... More
Supply and fixing of MCB 6 A to 32 Amps, 240 Volts single pole fix in position where directed complete all as specified and directed.

20

-

-

... More
Material and labour for boring under road by means of using trenchlesss technology manually with and including GI pipe light grade of 80 mm dia with all fittings for passing through of UG cable/ pipes etc all as specified and directed.

20

-

-

... More
Supply and fixing PVC insulated multistranded copper cable 1.5 sqmm three core multistanded flexible 1100 volts complete all as specified and directed

120

-

-

... More
Excavation in trenches not exceeding 1.5 mtrs wide and not exceeding 1.5 mtrs in depth for laying of cables including getting out in any kind of soil complete all as specified and directed.

335

-

-

... More
Excavation in trenches not exceeding 1.5 mtrs wide and beyond 1.5 mtrs in depth for erection of PCC pole including getting out in any kind of soil complete all as specified and directed.

2

-

-

... More
Returning filling in including spreading, leveling ,and well ramming, in layers not exceeding 25 cm each layer of any kind of soil all as specified and directed.

140

-

-

... More
Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point all as specified and directed.

195

-

-

... More
Material and labour sand cushioning (dry sand) to underground cable for cable protection 23 cm thick in two layers (8 cm thick before laying of cables and 15 cm thick after laying the cable and punning down the sand to 18 cm thickness) complete all as specified and as directed (Note:- Only punned thickness 18 cm of sand shall be measured for payment purposes).

100

-

-

... More
Supply and laying un-reiforced precast concrete cable cover class LV type-1 Size 250mm X 150mm X 40mm all as specified and directed

8000

-

-

... More
Material and labour in replacement GI tubing light grade 40 mm bore complete with all fittings like bends, sockets, elbows and fixing clamp of suitable size for passing through cables under the floor, along the wall or along the pole complete all as specified and directed.

25

-

-

... More
Day to day complaints of street lights of various type for working height varies from 9m to 15m in the jurisdiction of AGE E/M, GE (N) Patiala within 15 km radious incl removing carbon from LED light connection by deploying dedicated team having the experience in the same field. Contractor has to provide all required Tool and plants for street light fault rectification. Contractor will make record of all given complaints and rectify complaints updated on daily basis. Street light complaints should be rectified within 24 hrs after intimation via any communication mode. Contractor is to collect serviceable lights from E/M stores and deposit U/S LED lights back to store. If the complaint is not rectified within stipulated time, contractor will bear penalty of Rs 100 per day per complaint. Note :- (i) Necessary suitable vehicle shall be contractors own arrangement for carrying man power, tools and store. (ii) One repair/replacement of street light shall be counted as one job. (iii) The complete arrangement ie. veh, manpower tool and plants is inclusive in this quoted rate.

750

-

-

... More
Supply and fix in replacement electronic driver with power factor correction suitable for 45/50/60 Watt LED street lights, input AC 85-300V, input frequency 50/60 Hz, output voltage DC 22-38V, output current 1500mA (+-) 5%, waterproof level :IP 65, shell material : aluminium with IS 15885 complete all as specified and as directed.

60

-

-

... More
Supply and fix in replacement electronic driver with power factor correction suitable for 70-90 watt LED street lights, input voltage 70V AC to 300 V AC , power factor 0.99 (Unity) , over voltage 300 V cutt off, short and open circuit protection isolated, surge protection up to 10 to 12 Kv, maximum output voltage 55 Kv, maximum current up to 1.5a waterproof level : IP 65, shell material : aluminium with IS 15885 complete all as specified and as directed.

70

-

-

... More
Material and labour as in replacement brackets 1.2 m long made to shape fabricated out of GI pipe Light grade ISI marked 40 mm dia incl provn of socket nipple welded at one end to suit the light fitting and fix to pole including clamps with nuts and bolts of suitable size cutting, drilling and welding its fix to pole and applying two coat of synthetic enamel paint over a coat of red oxide primer all as specified and directed

12

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.