Military Engineer Services Tender
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Costs
EMD
₹ 60,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_684088_1Bid Award Id
ViewTender No
GE/LDH-45/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
All as per item No.2 above but DG set of capacity 40 to 62.5 KVA.
4
-
-
... More
All as per item No.2 above but DG set of capacity 7.5 to 30 KVA.
4
-
-
... More
S&F in replacement diesel filter element with O ring for Gen set of capacity 100/82.5 KVA complete all as specified and directed .
2
-
-
... More
All as per item No.5 above but DG set of capacity 40 to 62.5 KVA.
8
-
-
... More
All as per item No.5 above but Gen set of capacity 7.5 to 30 KVA.
8
-
-
... More
S&F in replacement lubricating oil filter with O ring for Gen set of capacity 100/82.5 KVA complete all as specified and directed .
2
-
-
... More
All as per item No.8 above but DG set of capacity 40 to 62.5 KVA.
8
-
-
... More
All as per item No.8 above but Gen set of capacity 7.5 to 30 KVA.
8
-
-
... More
S&F in replacement by- pass filter element with 'O' ring for Gen set of capacity 100/82.5 KVA complete all as specified and directed .
1
-
-
... More
All as per item No.11 above but DG set of capacity 40 to 62.5 KVA.
2
-
-
... More
All as per item No.11 above but Gen set of capacity 7.5 to 30 KVA.
2
-
-
... More
S&F in replacement air cleaner element (inner) with O ring for Gen set of capacity 100/82.5 KVA complete all as specified and directed .
1
-
-
... More
All as per item No.14 above but DG set of capacity 40 to 62.5 KVA.
4
-
-
... More
S&F in replacement air cleaner element (Outer) with O ring for Gen set of capacity 100/82.5 KVA complete all as specified and directed .
1
-
-
... More
All as per item No.16 above but DG set of capacity 40 to 62.5 KVA.
6
-
-
... More
All as per item No. 16 above but DG set of capacity 7.5 to 30 KVA.
6
-
-
... More
Dismantling and repair to self starter assembly 24 volt DC for gen set 100/82.5 KVA including rewinding of armature, replacement of carbon bush, bearing and worn out nut bolts etc and refixing all as original including testing complete all as specified and directed .
1
-
-
... More
All as per item No.19 above but DG set of capacity 40 to 62.5 KVA.
2
-
-
... More
All as per item No.19 above but Gen set of capacity 7.5 to 30 KVA.
3
-
-
... More
Dismantling of water pump assembly for Gen set 100/82.5 KVA, repairing the same including replacement of water body repair kit, water seal and worn out nuts, bolts, gasket etc and refixing & testing complete all as specified and directed .
1
-
-
... More
All as per item No.22 above but DG set of capacity 40 to 62.5 KVA.
1
-
-
... More
All as per item No.22 above but Gen set of capacity 7.5 to 30 KVA
2
-
-
... More
Dismantling and removing of radiator assembly for Gen set 100/82.5 KVA, cleaning the same with descaling solution and repairing the damage fins by brazing/ soldring etc re-fixing the same to its position inculding replacement of worn out nut bolt, gasket etc hose pipe with clamp etc complete all as specified and directed.
2
-
-
... More
All as per item No. 25 above but DG set of capacity 40 to 62.5 KVA.
9
-
-
... More
All as per item No. 25 above but Gen set of capacity 7.5 to 30 KVA
9
-
-
... More
S&F in replacement lead acid battery 12 volt, DC 70 AH complete all as specified and directed.
1
-
-
... More
S&F in replacement lead acid battery 12 volt, DC 90 AH complete all as specified and directed
1
-
-
... More
S&F in replacement lead acid battery 12 volt, DC 150 AH complete all as specified and directed .
1
-
-
... More
S&F in replacement Rotary type 2 pole 2 way selector switch complete all as specified and directed
4
-
-
... More
S&F in replacement Rotary type 3 pole 2 way selector switch complete all as specified and directed
4
-
-
... More
S&F in replacement Automatic battery charger, 24 V DC, 10 A complete all as specified and directed
6
-
-
... More
S&F in replacement CTs, 150/5 A, Cl complete all as specified and directed.
2
-
-
... More
S&F in replacement Auto / manual switch complete all as specified and directed.
2
-
-
... More
S & F in replacement complete fuel pipe set with benzo washer (feul tank to pre fule fitlter/ fuel fitler to FIP & fuel return pipe ) for 7.5 KVA to 82.5 KVA DG Set as per existing make and size complete all as specified and directed.
6
-
-
... More
M&L dismantaling alternator of DG set capacity 30 to 82.5 KVA, transporting to civil workshop for repair. strip opening of alternator, taking out burnt copper winding, cleaning the slouts of stator and cleaning the roter, rewinding the stator field coil with supper enameled copper winding wire of existing size and gauge including provision of new insulating material of class 'E', insullation varnishing, heating etc re-assembling the same, bringing back to its original location, connecting and testing complete all as specified and directed .
1
-
-
... More
Supply & fixing pressure gauge 0 to 300 PSI panel mounting type as per existing dia complete all as specified and directed .
2
-
-
... More
Supply and wrapping of asbestos rope 20mm dia superior quality on exhaust pipe of Gen set complete all as specified and directed .
60
-
-
... More
M&L scraping of old painted surface of Gen set of capacity 7.5 to 62.5 KVA including panel, fuse tank etc, prepration of steel surface painting of Gen set, inculding all accessories with two coats of super enamelled paint of approved colour and over a coat of primer inculding marking of SM/ MES No. of suitable size with white paint complete all as specified and directed .
4
-
-
... More
Supply & fixing in replacement copper conductor, single core of size 10.00 sq mm as in battery lead complete all as specified and directed .
10
-
-
... More
Supply & fixing in replacement battery terminal of brass complete all as specified and directed .
14
-
-
... More
Supply & fixing in replacement power contactor 4 pole 415 Volt with coil complete of capacity upto 80 Amp as per existing make or model complete all as specified and directed .
2
-
-
... More
Supply & fixing in replacement engine starting relay, 24 Volt DC On/Off setting time 0 to 10 Sec complete all as specified and directed .
3
-
-
... More
Supply & fixing aluminium lugs of size 10 sqmm to 95 sqmm complete all as specified and directed .
80
-
-
... More
S & F in replacement on load Changeover Switch 415 V 4 pole of capacity 63 Amps complete all as specified and directed .
2
-
-
... More
S & F in replacement off load Changeover Switch with Sheet Metal Enclosure 415 V 4 pole of capacity 63 Amps complete all as specified and directed .
4
-
-
... More
S & F in replacement off load Changeover Switch with Sheet Metal Enclosure 415 V 4 pole of capacity 100 Amps complete all as specified and directed .
4
-
-
... More
S&F in replacement Over load relay 16 to 100 Amps 415 V complete all as specified and directed .
8
-
-
... More
S&F in replacement Single phase preventor suitable 12.5HP motor starter VSP-3 etc. complete all as specified and directed .
5
-
-
... More
S & F in replacement Star delta timer ETR suitable upto 35 Amp complete all as specified and directed .
5
-
-
... More
S&F in replacement of phase indicating lamp complete all as specified and directed
9
-
-
... More
Disconnecting and taking out of DG set 40 KVA Make :- as per existing No of Cylinder :- 04 including disconnecting all electrical connections and transporation to work shop and back after carry out necessary repair and replacement of worn out defective parts including preventive maintaince of connected assemblies. Reassembling the same after repairs including testing and commissioning at site complete all as specified and directed including replacement of the following spare parts .
(Note :- cost of spare parts to be replaced will be masured and paid seperatly under item Nos 54 to 62 here in after under respecive items but cost of replacement shall be deemed to be included in this item).
1
-
-
... More
Supply and fixing in replacement of cylinder Liner complete all as specified and directed.
4
-
-
... More
Supply and fixing in replacement of Piston complete all as specified and directed.
4
-
-
... More
Supply and fixing in replacement of Piston ring set complete all as specified and directed.
4
-
-
... More
Supply and fixing in replacement of exaust valve seat complete all as specified and directed.
4
-
-
... More
Supply and fixing in replacement of inlet Valve seat complete all as specified and directed.
4
-
-
... More
Supply and fixing in replacement of valve pair complete all as specified and directed.
4
-
-
... More
Supply and fixing in replacement of Hose flexible complete all as specified and directed.
1
-
-
... More
Supply and fixing in replacement of CAM gear Assembly complete all as specified and directed.
1
-
-
... More
Supply and fixing in replacement of turbo charger Assembly complete all as specified and directed.
1
-
-
... More
M& L for Fabrication, Installing, Testing & Commissioning of automatic mains failure panel shall be of suitable size factory made outdoor cubical type front openable fabricated from CRCA steel sheet 1.6 mm thick complete as per manufacturer specification of Diesel Engine suitable for DG Set of capacity 82.5 KVA grouted in floor by providing PCC 1:2:4 type B-2 foundation of suitable size as per manufacturers recommendations complete in all respects and consisting of the following :-
(i) Contactor ML of suitable capacity (ii) Aluminium bus bar of current rating 320 Amps (iii) Sensitivity relay set unit with auxiliary relay CT's (iv) Electronic latch circuit with tripping indication (v) Instantanous tripping device suitable for complete panel over current 0.5 Amp (vi) Reset facilities for complete protection of AMF Panel (vii) Self sequiential starting relay unit 12 volts DC complete with alarm and power contactor (viii) Electronic timer 220 Volts for main contactor with 1 No NC auxiliary contactor (ix) Electronic timer 220 volts for fuel cut off operation for with 1 No NC auxiliary contactor (x) Battery charging unit 24 volts 10 amp complete with digital volt metre & Amp metre (xi) Electrical starter 12/24 volts DC as per manufacturer's design (xii) relays, timers, set of CTs for metering & protection and energy analyzer to indicate currents, phase and line voltages, frequency, power factor, KWH, KVARH, KVAH & provision for overload, short circuit, restricted earth fault, under frequency (xiii) MCCB 250 Amps 4 Pole 50 KA & MCCB 200 Amp 50 KA breaking capacity for main supply & DG Supply adjustable over load and adjustable short circuit each 01 No (xvii) The AMF panel shall have manually by pass arrangement in case of failure of AMF Panel, (a) at Signal Centre (b) at Pump House CG complex, complete all as manufacturer reqd of as specified.
2
-
-
... More
S & F in replacement AVR for alternator suitable 7.5 KVA to 82.5 KVA DG Set as per existing model or make complete all as specified and directed .
6
-
-
... More
S & F in replacement VMR relay for AMF suitable for 7.5 KVA to 82.5 KVA DG Set as per existing model or make complete all as specified and directed .
4
-
-
... More
M & L for Supply in replacement of LED backlit Double sided signage boards with IP-65 at MES installations, vinyl print on acrylic sheet of engraved bold letters, which is back lit with High grade, high brightness LED modules, inbuilt SMPS driver, without battery backup, operating voltage 80V – 270V AC, Life period 50,000 hrs, LPM technology, size of 4 ft X 04 ft including fabrication of heavy duty pipes, complete all as specified under satisfaction of Engr-in-charge.
8
-
-
... More
S&F in replacement of 'V' belt for alternator for 7.5 KVA to 82.5 KVA DG Set as per existing specification and make complete all as specified and directed .
8
-
-
... More
S&F in replacement Silencer alongwith clamps & fittings, made as per existing for DG Set capacity of 7 KVA to 82.5 KVA of any make including painting of synthetic enamel with prime coat of red-oxide primer complete all as specified and directed .
1
-
-
... More
S & F in replacement rubber hose for air intake as per existing Size 7.5 KVA to 82.5 KVA DG set complete all as specified and directed .
10
-
-
... More
S & F in replacement rubber hose set for coolant circulation from radiator to water body as per existing size for DG Set 7.5 KVA to 82.5 KVA complete all as specified and directed .
8
-
-
... More
Supply and pouring engine oil 15 W 40 for DG Set complete all as specified and directed .
220
-
-
... More
Supply and pouring KOEL care Genuine coolant premix as supplier's Packing complete all as specified and directed .
100
-
-
... More
Supply & Filling of battery distilled Water as per supplier's packing by 100% TDS and PH Tested complete all as specified and directed .
60
-
-
... More
M&L for dismantling of electric connection of DG Set (Cap 40 KVA to 82.5 KVA) and removing the DG set from existing positon, repair the platform by using PCC (1:2:4) type B-1 using 20mm graded stone aggregate 100 mm thick, plaster (1:4) around the platform and apply three coat of white wash, refixing the DG Set in original position incl electric connection after repair complete all as specified and directed .
Note:- T&P shall be included in quoted rates.
2
-
-
... More
M & L preparation surface of sewage treatement plants comprising 02 No sluge pumps, 02 No air blowers, 02 No water filters, 08 No electric motors with pumps 12.5 HP, water pipe, LT panel etc and applying two coats of synthetic enameled paint of existing colour including writing 'MES' machine number of size as directed using white paint complete all as specified and directed .
1
-
-
... More
M & L for cleaning of sewage collection tanks, cleaning of equilisation tank, dried bed chamber incl removal of mud/solid sludge (approx quantity 16 cum) from all the tanks and removal out of MD land including filling required sized gravels to make up the level and filling sand to dried beds complete all as specified & directed.
1
-
-
... More
Supply and filling hypochloride solution Gde-I conforming to IS 11673-1992 having 10 to 15% active liquid chlorine in STP etc complete all as specified and directed .
150
-
-
... More
M&L for pouring the JPCE-2 solution for bacteria growthing culture concentration complete all as specified and directed .
60
-
-
... More
Material and labour for servicing and replacement of required qty of FAB Media (Min qty 8 Cum) for STP capacity 0.2 MLD FAB technology with high specific surface area typically 400-500 sqm /cum, colour black media height 16mm media dia meter 22mm, type of media MBBR, MOC of media is Virgin PP UV stabilized, type of structure cylindrycal with external fins, Ratio of PSA/TSA 75%, speific weight of surface area 0.37 kg/sqm, and high oxygen transfer efficiency, as per manufacturer recommendation complete all as specified and directed .
1
-
-
... More
Material and labour for servicing and replacement of required qty of filter media of required size/ qty of DMF & ACF as per manufacturer recommendation and as approved by GE for STP capacity 0.2 MLD, complete all as specified and directed .
1
-
-
... More
Material and labour for servicing and replacement of min 8 cum qty of Tube settler media mvc pvc, weight per cubic meter 60 kg (approx), working temperature 60 degree celcius (Max) as per manufacturer recommendation for STP capacity 0.2 MLD, complete all as specified and directed .
1
-
-
... More
Testing of (STP) treated water samples from NABL accrediated lab for following parameters and submitting the results to MES complete all as specified and directed by Engr-in-Charge.
(a) PH
(b) BOD
(c) COD
(d) TSS
(e) Fecal coliform
Note : Rate of sample collection,transportation shall be born by the contractor without any extra cost.
8
-
-
... More
M&L for in replacement of NRV 80 mm horizontal type of brass sheet fitted complete all as specified and directed.
8
-
-
... More
M&L for removing rewinding and refixing of sewage disposal motor capacity of 5.5 HP at sewage installation, opening of motor,cutting removing old burnt winding coils ,cleaning filling the starter slots necessary mechanical works for shaft/bearing housing/mechnaical seal/volute/ volute base, greasing/oiling all moving parts , rewinding with suitable gauge of super enamelled copper conductor including winding with fibre cloth/PVC insulated winding paper, superior quality varnishing, servicing/replacement of pump including replacement of spares , lifting eye bolt, cable gland, protection tube, cable seal, terminal board, cable bracket, brearing cover, double mechanical seal,tie for stand,support bracket, guide shoe, moisture sensor, potting cup, Gland iron box,S & F Duck foot bend, hose clip ball bearings, thermal over load protector, hose nipple, shaft bleaching, two coats of synthetic enamel spray painting on body , suitable mains connections from coil to terminal box,preparing and inserting coil running/starting winding interconnecting, fixing, soldering, jointing, heating, drying up coils, connection at site, to and for transportation, testing at site and satisfactorily running all as specified and directed .
Note :- (a) Lifting the moter & lowering after reapir shall be arranged by the contractor without any extra cost.
(b) Transportaion form site to workshop and back to site shall be included in quoted rates.
5
-
-
... More
All as per srl item No 84 above but motor capacity 7.5 HP.
4
-
-
... More
All as per srl item No 84 above but motor capacity 10 HP.
2
-
-
... More
All as per srl item No 84 above but motor capacity 12.5 HP.
3
-
-
... More
All as per srl item No 84 above but motor capacity 1.0 HP.
2
-
-
... More
All as per srl item No 84 above but motor capacity 2.0 HP.
2
-
-
... More
All as per srl item No 84 above but motor capacity 3.0 HP.
6
-
-
... More
S&F in replacement of PVC sheatherd flat submersible cable 1100 V grade copper conductor multi core 3 x 10 sqmm complete all as specified & directed..
300
-
-
... More
Material & labour in replacement of earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of the earth plate at a depth not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed with layers of charcoal dust and common salt, earth electrode GI strip 32 x 6mm connected to GI earth plate electrode by means of bolts, nuts, check nuts and washers of galvanized iron and thimbles and other end of earth strip connected to test point and protected by galvanized iron light grade 50mm bore and GI pipe 20mm bore light grade with funnel and wire mesh for watering including necessary excavation and earth works. PCC chamber in cement concrete (1:3:6) type C-2 using graded stone aggregate and RCC cover in 1:2:4 and all as shown in Electrical Plate No. 3 of MES Schedule (Part-I) of 2009 complete all as specified and directed.
Note:-(a) The unit rate shall include for protection pipe, GI water pipe, wire mesh, funnel and excavation.RCC pit cover ,test point,4mm dia galvanised iron wire from top of earth plate upto 5 m above ground level and if GI protection is less than 5 meter, no price adjustment shall be made. (b) PCC pit shall be provided at least 1 mtr away from the earth pit and not just on the earth pit andextra cost of additional length of water pipes and fittings, junction, elbow etc shall be deemed to be included in the unit rate.
(c) If the testing result of earthing work is not been found satisfactory then the contractor shall do other earthing work at his own cost and nothing shall be permissible on this account. (d) Earthing work will be carried out in presence of MES representative
20
-
-
... More
Material and labour fas in repair of MS Structure work conforming to Fe-290 Grade E-165, with MS Angle, Fastners, Tie Rods, for supporting pipe and pump footing including cutting to dead length where required, notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing and fitting angle cleats, fish plates, gusset plates etc., also for wedging, plumbing, truing up including applying two coats of synthetic enamel paint over a coat of red oxide primer on exposed surfaces and only a coat of red oxide primer on un-exposed surfaces and fixing complete all as specified and directed
300
-
-
... More
S & F PVC insulated copper cable with cross sectional area 2.5 sqmm, 3 core complete all as specified and directed.
400
-
-
... More
M&L preparing old steel surfaces and applying two coats of synthetic enamel paint over a coat of primer, complete all as specified and as directed.
30
-
-
... More
Taking down old unserviceable pipe line and S&F pipe 100mm bore GI heavy grade with double ends flanged, 4 hole for sewage pump fixing complete with nut bolt and gasket as specified and directed. Notes :- Rates of nut, bolt and rubber washer shall be included.
90
-
-
... More
Taking down old unserviceable pipe line and S&F pipe 80 mm bore GI heavy grade with double ends flanged, 4 hole for sewage pump fixing complete with nut bolt and gasket as specified and directed. Notes :- Rates of nut, bolt and rubber washer shall be included.
90
-
-
... More
Removing the cover (CI or RCC)/ opening any type and Balling out (dewatering) of sewage water, semi liquid and all other foreign organic and inorganic material and solid suspended contents and floating matters inside the sewage plants/ sumps of any size and depth and any capacity by mechanical pumping by plugging inlets as required, de-sludging and getting out, removing including carrying it outside the defence/ cantonment area upto a distance of 1.5 KM deposited where directed in borrow pits and covering the buried pit with 15 cm thick layer of earth / soil and re-fixing the main hole cover to its original position all as directed by Engineer-in-Charge and making sewage system such as sewage plants/ sumps fully functional to the entire satisfaction of Engineer-in-Charge.
5
-
-
... More
Bailing out mud/sludge (max 10 cum) from sewage sump by using mechnical means/ sewer suction cum jetting machine and disposing off the sludge at the bottom of the tank & thrown away upto 1.5 Km away from the camp site complete all as specified and directed .
Note for srl item No 98 & 99 :-
1. Working is in foul conditions. 2. Solid contents after dewatering shall only be measured and paid.
3. Sewage/ sludge shall be removed in closed container mounted on vehicle.
4. Skilled supervisor deputed on site by the contractor during sump cleaning , rate for the same shall be included in quoted rates.
5
-
-
... More
S & F in replacement direct online starter 3 phase , 415 volt , (DOL) in S/S housing with magnetic,thermal overload relay range 10 to 25 Amp complete suitable for electric motor upto 12.5 HP complete all as specified and directed .
10
-
-
... More
Supply and replacement of 1100 volts grade heavy duty PVC insulated flat submerssible cable 6 sqmm, 3 core with copper conductor complete all as specified and directed .
300
-
-
... More
M& L for repair of Motor starter panel of sewage/STP installations by welding & painting inclding replacement of Over load realy 0 to 63 Amp 415 V, Power Contactor as per existing rating or model, Single phase preventer VSP-03, MPCB for motor protection, Digital multifunctional meter 0-200 Amp- & 415 Volt , Phase indication lamp complete all as specified and directed .
4
-
-
... More
Supply and fixing in replacement butterfly valve bore size 50 mm and full rated on dead-end-service and ductile iron and also bi-directionally tested in both directions and are bubble tight with zero leakage and meet and face to face dimention including suitable size with nuts, bolts, washer and rubber gasket all as required and directed
1
-
-
... More
All as per srl item No 103 above but size of 100 mm bore.
2
-
-
... More
Supply and fixing in replacement of MCCB of current rating 160 Amps, 4 pole, 415 volts AC, 36 KA rupturing capacity with adjustable thermal type release including taking down old Unsv MCCBs complete all as specified and directed.
6
-
-
... More
M & L for Unplasticised PVC pipes of size 110 mm pressure rating 10 kg/sqcm and fixed complete to walls ,ceilling or in floors etc including fittings such as socket, bend, elbow, union etc. complete all as specified & directed .
40
-
-
... More
M & L for Precast reinforced cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) cover slabs in 75 mm thick (for holes on sewage sump) similar articles with plain faces and setting in CM (1:6) with joints to match including formwork and moulds etc complete all as specified and directed .
20
-
-
... More
XLPE insulated heavy duty electric cable with aluminium conductor 1100 volt grade cross sectional area 35Sq mm 3.5 core complete all as specified and directed including taking out existing.
300
-
-
... More
XLPE insulated heavy duty electric cable with aluminium conductor 1100 volt grade cross sectional area 50 Sq mm 3.5 core complete all as specified and directed including taking out existing.
200
-
-
... More
XLPE insulated heavy duty electric cable with aluminium conductor 1100 volt grade cross sectional area 25Sq mm 3.5 core complete all as specified and directed including taking out existing.
200
-
-
... More
XLPE insulated heavy duty electric cable with aluminium conductor 1100 volt grade cross sectional area 16Sq mm 4 core complete all as specified and directed including taking out existing.
200
-
-
... More
Excavation in trenches n. exc. 1.5 metre wide for taking out/ laying pipe line etc. and not exceeding 1.5 metre deep and getting out in soft/ loose soil complete all as specified & directed.
243
-
-
... More
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified & directed.
170.1
-
-
... More
Removal of excavated surplus spoil to a distance n.exc 50 metre and depositing where directed at level not exceeding 1.5 metre above the starting point complete all as specified & directed.
72.9
-
-
... More
Supply and spreading of fine river sand and gentally punning for laying of under ground cables. Note :- Punned thickness 18cm shall be measured for payment.
72.9
-
-
... More
Supply and laying in replacement of sub class 'B'common burnt bricks, old size designated 75, laid dry flat with width equal to length of brick & with gaps between the adjucent bricks n.exc 10mm as cover laid over the cable to give mechanical protection to under ground cable complete all as specified and directed.
3
-
-
... More
All as per item No 116 above but except bricks complete all as specified and directed.
4.2
-
-
... More
Supply only First Aid Kit box No-08 made of Stainless steel (Size : 360 mm x 150 mm x 80 mm) caintaining following items.
(a) Dettols bottle100 ml 02 bottles
(b)Antiseptic Ointment 100 mg
© Crocin tabletes 01 strips ( containings 10 Tablets each).
(d) Hydrogen peroxide 50 ml 01 bottle (e) Cotten small rolls 2 Nos
(f) Cotten strip small roll 04 Nos
(g)Moov tube 01 Nos
(h) Betadine Tube 100 mg (j) Bendaid -05 Nos
6
-
-
... More
Supply and fixing in replacement of cast iron sluice valve suitable for 100mm bore pipe with flanged ends drilled ISI marked class PN-1.6 conforming to IS- 14846 with stainless steel spindle, CI gate with brass nut, bolt, washer and rubber packing for connecting pieces etc complete all as specified and directed.
4
-
-
... More
Supply and fixing in replacement of cast iron sluice valve suitable for 80mm bore pipe with flanged ends drilled ISI marked class PN-1.6 conforming to IS- 14846 with stainless steel spindle spindle, CI gate with brass nut, bolt, washer and rubber packing for connecting pieces etc complete all as specified and directed.
5
-
-
... More
M&L framed work as in repair such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed.
400
-
-
... More
M&L in replacement of 4mm dia galvanised steel wire 150x100mm mesh,made up into mattresses or cages, lapped, wired and laid/weld in position incl closing after filling as in repairs at sewage installations complete all as specified and directed .
250
-
-
... More
M&L for preparation new painted metal surfaces of any description, over 10cm in width or girth and appling two coat of synthatic enamil paint of approved tint complete all as specified and directed .
40
-
-
... More
M&L for lifting of Submerible type sewage pump ,capacity 10/ 7.5/5.5/3.0 HP and cleaing/removal of waste or chocking material, lowering after making serviceable , complete all as specified and directed .
Note:- Required T&P such as lifting chain – pulley block and tripod (not less than 2 ton capacity and 40 feet lifting arrangement portable type ) and other lifting arrangement shall be deemed included in quoted rate
(b) Minor repair shall be made and including in quoted rates.
10
-
-
... More
M& L for Cleaning & servicing of air blower electric driven 415 volt AC supply 12.5 HP of capacity 180 cum per hour including replacement of shaft bearing as per existing and filling in new compressor oil ( Approx 5 ltr ) etc complete all as specified & directed
2
-
-
... More
Supply, Install, Testing and commissioning LT Distribution Panel size of 1.2mx1.2mx0.45m (CPRI type tested) cubical type IP-65, Outdoor type as in replacement to conforming to IS 5039, factory fabricated made out of 3.15 mm thick CRCA sheet outer & 2 mm thick CRCA sheet inner of suitable size to accommodate all accessories /fittings compartmentalized in consruction to accommodate in incoming MCCB and TPN bus bars and outgoing feeders. The TPN bus bars shall be insulated with colour coated heat shrinkable sleeve and shall be mounted on DMC / epoxy insulator . The incoming as well as outgoing MCCB's shall have extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC/ Epoxy insulators having provision for termination of incoming and outgoing cables. All extension links interconnetions shal colour coated sleevs. the cubicle shall frame work, bottom & 45 CM long 4 legs of size 50 x 50x 6 mm angle iron, grouted in PCC 1:3:6 as directed by Engr-in- Charge. A detacheable gland plaate of thickness not less than 3 mm should be used at the bottom for entry of armoured cable of adequate size compression glands, the panel shall be painting with powder coated finish with RAL 7032 SIEMENS GRAY structure after seven tank phosphating treatment, front & back opening type and fixing 02 Nos dange notice plate indicated in hindi and English with double shutter and shall have louvers and airvent gasket for natural flow of air neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of following.Note :- (i) LT Panel board should be type tested from CPRI (A copy of valid CPRI type tested report to be enclosed while obtaining approval of GE (ii) SLD diagram of LT panep will be got approved form GE before pacing the order and final diagram will be fixed on the front and rear door (iii) Rate for the same deemed to include in the quoted rates
(i) incoming MCCB 160 Amp, 35 KA, 4 Pole 415 Volt - 01 Nos
(ii) out going MCB 100 Amp 4 pole 415 volt 10 KA - 02 Nos
(iii) Aluminium bus bar for 3 Ph & Neutral 320 Amp- 01 Set
(iv) Volt meter 0-500V (v) Ammeter with CTs 50 A and selector switch
(vi) Phase indicator neon lamps RYB -01 Set of 03
(vii) Fully automatic star delta starter suitable for 3 Phase submersible motor suitable for 30/35 HP capacity -02 (01 working and 01 standby), including change over 160 Amp complete all as specified and as directed.
(viii) Single phase preventor for each starter.
(ix) MCB TPN 40 Amp -02 Nos
2
-
-
... More
Supply, Install, Testing and commissioning in replacment of LT Distribution Panel size of 1.2mx1.2mx0.45m (CPRI type tested) cubical type IP-65, Outdoor type conforming to IS 5039, factory fabricated made out of 3.15 mm thick CRCA sheet outer & 2 mm thick CRCA sheet inner of suitable size to accommodate all accessories /fittings compartmentalized in consruction to accommodate in incoming MCCB and TPN bus bars and outgoing feeders. The TPN bus bars shall be insulated with colour coated heat shrinkable sleeve and shall be mounted on DMC / epoxy insulator . The incoming as well as outgoing MCCB's shall have extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC/ Epoxy insulators having provision for termination of incoming and outgoing cables. All extension links interconnetions shal colour coated sleevs. the cubicle shall frame work, bottom & 45 CM long 4 legs of size 50 x 50x 6 mm angle iron, grouted in PCC 1:3:6 as directed by Engr-in- Charge. A detacheable gland plaate of thickness not less than 3 mm should be used at the bottom for entry of armoured cable of adequate size compression glands, the panel shall be painting with powder coated finish with RAL 7032 SIEMENS GRAY structure after seven tank phosphating treatment, front & back opening type and fixing 02 Nos dange notice plate indicated in hindi and English with double shutter and shall have louvers and airvent gasket for natural flow of air neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of following.Note :- (i) LT Panel board should be type tested from CPRI (A copy of valid CPRI type tested report to be enclosed while obtaining approval of GE (ii) SLD diagram of LT panep will be got approved form GE before pacing the order and final diagram will be fixed on the front and rear door (iii) Rate for the same deemed to include in the quoted rates
(b) Volt meter 0-500 volts, digital type, panel mounted, flush type, three phase of size 96x96mm complete with built in selector switch - 01 No. (c) multifunction digital meter (0-500 Volts ) 96x96mm square type with inbuilt selector swich-01 No (voltage,Current, KWH, PF,Amp etc).
(d) Indicator lamp LED type on all phases (R,Y,B) - 03 Nos.
(e) MCCB 200 Amps, 3 phase, 415 Volt, 4 pole, breaking capacity 35 kA rating with adjustable thermal & fixed magnetic type - 01 No (incoming).
(f) MCCB 160 Amps, 3 phase, 415 volt, 4 pole, breaking capacity 25 kA rating with adjustable thermal & fixed magnetic type-02 Nos (outgoing).
(g) On load Changeover switch 160 Amps, 3 phase, 415 volt, 4 pole,fitted in panel box . (h) MCB 32 Amps, SPN, 230 volt, breaking capacity 10 kA rating -02 Nos (outgoing).
2
-
-
... More
Supply installng, testing and commissioning in replacement of floor mounted LT panel size of 1.2mx1.2mx0.45mout door type of suitable size cubical type factory made, weather and vermin proof made out of CRCA sheet 3.15 mm thick appropriate size of panel 60 cm X60 cm X45 cm and 04 Nos legs on angle iron 40x40x5mm each 45 cm long panel duly powder coated in side & out side with 7 tank process heaving insulated bus bar TPN with openable shutter on both side (Front and rear side) with locking arrangement duly pre-wired with suitable size of copper conductor cable with proper size of copper lugs/thimbles and connecting to MCCBs with suitable size aluminium strip duly bended and fixed with nut & bolts and washers from bus bar to MCCBs and legs grouted in PCC 1:2:4 type B:1 (20 mm graded stone aggregate) with gland packing to provided for cable approved complete as under and incl following accesseries:- (a) 04 strips of aluminium bus bar with insulation colour sleeves of capacity 100 Amp fixed on PVC heat shrinkable insulator heavy duty.
(b) Volt meter 0-500 volts, digital type, panel mounted, flush type, three phase complete with built in selector switch - 01 No. (c) multifunction digital meter (0-500 Volts ) with in built selector swich-01 No (voltage,Current, KWH, PF,Amp etc).
(d) Indicator lamp LED type on all phases (R,Y,B) - 03 Nos.
(e) MCCB 63 Amps, 3 phase, 415 Volt, 4 pole, breaking capacity 16 kA rating with adjustable thermal & fixed magnetic type - 01 No (incoming).
(f) MCCB 40 Amps, 3 phase, 415 volt, 4 pole, breaking capacity 10 kA rating with adjustable thermal & fixed magnetic type-02 Nos (outgoing).
(g) On load Changeover switch 32 Amps, 3 phase, 415 volt, 4 pole,fitted in panel box . (h) MCB 32 Amps, SPN, 230 volt, breaking capacity 10 kA rating -01 Nos (outgoing).