Military Engineer Services Tender

... More
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.

Military Engineer Services - MES Tender

Works
Electrical Works
Eprocure
Opening Date8 Feb 2025
Closing Soon7 Mar 2025
Tender Amount₹ 44,99,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L for servicing of Air Handling units by removing the filter, vaccumising the filter, washing the filter and reinstalling the cleaned filter, brush the cooling coil and spray the foam coil cleaner including rinsing of coil, alignment of shaft & motor, servicing of chilled water line strainer for the AHUs, tightening of terminals of motor, replacement of V belts, replacement of bearings complete all as specified :- Note :- (i) The rate quoted deemed to be inclusive of blowing out the dust, chemical cleaning by spraying the organic based scale removing agent (Vaniklin) at the appropriate ratio till removal of complete dut & scale deposits in the fin area of evaporator coil, flushing through for proper air flow across he coil, cleaning of air filters, greasing of blower motor, replacement of unserviceable bearings, V belts, water drain lines, renewal of rusted sheet metal screws, applying synthetic enamel paint over a coat of primer on the rusted portion and testing & commissioning the unit.

-

-

-

... More
4000/5000 CFM

3

-

-

... More
8000/10000 CFM

3

-

-

... More
15000/20000 CFM

3

-

-

... More
M&L for carrying out servicing/ overhauling, repairs and maintenance of Cooling tower of upto 100 TR water cooled chiller type central AC plant by dismantling/ taking down the CT fan motor of flange mounted extended type shaft upto 7.5 HP, 3 Phase, 415 volts, 50 Hz, along with fan assembly and including cleaning & removal of scales, inspection, cleaning and replacement of PVC fills, PVC eliminator, FRP louvers, motor cover, splash cups etc complete including renewal of all corroded bolts & nuts, terminal block and re assembling, fixing in position, fixing of fan blade and alignment of the fan blade for the suitable air throw of the cooling tower, painting with two coats of synthetic enamel paint over a coat of anticorrosive paint after preparation of surface, testing and commissioning the cooling tower motor all as specified and as directed Note :- (i) The spareswil be paid separately under respective items.

3

-

-

... More
Supply only Spares for carrying cooler tower of upto 125 TR water cooled chiller type central AC plant under relevant items :-

-

-

-

... More
PVC Fins 600x300x150mm.

100

-

-

... More
CT fan assembly cast aluminium alloy as per existing size.

1

-

-

... More
CT fan electric motor of capacity 2/3 HP with long shaft and blade, insulation class F, IP55 as per exisitng make.

1

-

-

... More
CT fan electric motor of capacity 5/7.5 HP with long shaft and blade, insulation class F, IP55 as per exisitng make.

1

-

-

... More
AI water sprinkler 2" to 5"

1

-

-

... More
FRP motor cover

1

-

-

... More
PVC branch pipes 63mm dia & 30 inch long

1

-

-

... More
M&L for leak testing of Air Conditioning Plant unit of comprising of condensor units and chiller units with pressure testing the complete plant by dry nitrogen gas by separating high side and low side, brzing and low side, rectifying the leakage by gas welding, brazing, pressure testing, vaccumising gas, gas charging the system with existing Refrigerant Gas, testing and commissioning complete all as specified and as directed by Engineer- in- charge of the following capacity of AC Plants are as under :- Note :- (i) Each Chiller unit, refrigerant gas will be paid and measured separately. (ii) The cost of the nitrogen gas shall be deemed to be included in the quoted rates.

-

-

-

... More
17 to 35 Ton

10

-

-

... More
70 to 100 Ton

15

-

-

... More
M&L for Dismantling the pump of following capacity, isolating suction/ delivery line connections, checking the worn out parts like impeller, shaft, stuffing box, shaft sleeve using micrometer and transporting to workshop for repairs, checking the conditions of bearings removing scales from impeller and pump housing, building the worn out metal of transmission shaft to required level, machining to the required size on lathe machine, grinding and finishing to match the sleeve and fixing into the housing, re- assembling, transport back to the installation, installing in position, check for alignment with dial gauge, inserting shims where necessary, refixing with coupling, tightening with torque wrench to required level, re- connecting the flanged pipe connections of suction,/ delivery, greasing for bearings including replacement of rubber insertion etc complete all as specified and directed: - Note:- Spares will be measured and paid separately under relevant schedule

-

-

-

... More
2 to 3 HP

6

-

-

... More
5 to 7.5 HP

5

-

-

... More
Supply only Spares for carrying cooler tower of upto 125 TR water cooled chiller type central AC plant under relevant items :-

-

-

-

... More
Shaft brushes with check nuts (stainless steel) for 2 to 3 HP Pump.

1

-

-

... More
Shaft brushes with check nuts (stainless steel) for 5 to 7.5 HP Pump.

1

-

-

... More
Ball bearings suitable for 2 to 3 HP Pump.

1

-

-

... More
Ball bearings suitable for 5 to 7.5 HP Pump.

1

-

-

... More
Metal coupling suitable for 2 to 3 HP Pump.

1

-

-

... More
Metal coupling suitable for 5 to 7.5 HP Pump.

2

-

-

... More
Gland packing end cover (Stainless steel of suitable grade) as per exiting make

2

-

-

... More
M&L or dismantling the defective induction motor of following capacity/ make/ class of insulation from foundation bed, disconnecting all electric supply connections, duly coupled with pump/ compressor, transporting to workshop removing burn out winding from starter/ rotar, rewinding with suitable gauge of super enamelled copper wire of approved make and replacing DE/ NDE bearings, insullation materials, varnishing, heating, greasing of bearings etc complete re- assembling, testing and commissioning of following motors all as directed including terminal block, bearings of motor complete all as specified and directed by Engineer - in- charge.

-

-

-

... More
3 to 5 HP

6

-

-

... More
7.5 to 10 HP

6

-

-

... More
M&L for Disconnecting, cutting and taking out unserviceable sealed unit compressor of package type air conditioner any make & model including removal, fitting/fixing of serviceable sealed unit compressor soldering, welding, brazing as required including charging of refrigerant gas and oil in the exchanged compressor, making electric & mechanical connections at site and testing on load, complete of the following capacity:-.

-

-

-

... More
5.5 Ton

4

-

-

... More
7.5 to 8.5 Ton

4

-

-

... More
12.5 Ton

4

-

-

... More
Supply only compressor of package type air conditioner complete of the following capacity:- (Make : Kirloskar / Copland / Danfoss.) NOTE:- (i) Micro processor based control comprising for following features- (a) Automatic capacity control reducing energy consumption. (b) Micro processor based sequence of starting / stopping of equipment with fixed time delay. (c) Alarm history giving cause of tripping. (d) LP/HP cut out. (ii) Fail safe features comprises the following:- (a) Under voltage protection (b) Single phase protection (c) Over load protection (d) Phase inbalance protection (e) Anti freeze protection (f) Power loss trip and shut down (iii) Set of water flow switches in condenser and chiller water line at intel and oulet. (iv) First charge of refrigerant gas and compressor oil as per manufacturer's recommendation.

-

-

-

... More
5.5 Ton

4

-

-

... More
7.5 to 8.5 Ton

4

-

-

... More
12.5 Ton

4

-

-

... More
S&F, Pre filter in sheet metal frame IN REPLACEMENT complete. of following size:-

-

-

-

... More
24″ x 24″ x 2″

30

-

-

... More
21"x21.5"x2''

25

-

-

... More
S&F, Expansion valve, Capacity 5/7.5/11/15/25 Ton IN REPLACEMENT complete all as directed.

8

-

-

... More
S&F, Solenoid valve, Capacity 5/7.5/11/15/25 Ton IN REPLACEMENT complete all as directed.

7

-

-

... More
S&F, V belt, IN REPLACEMENT complete. of following size:-

-

-

-

... More
A-29/30

20

-

-

20

-

-

20

-

-

20

-

-

20

-

-

... More
S&F, PVC float valve with PVC float.alluminium stem, fly nut complete screw for iron pipe IN REPLACEMENT of following size:-

-

-

-

... More
15 mm bore

8

-

-

... More
20mm bore

8

-

-

... More
S&F, Gun metal gate valve with iron wheel ISI marked IN REPLACEMENT of following size:-

-

-

-

... More
25mm bore

5

-

-

... More
40mm bore

5

-

-

... More
50mm bore

5

-

-

... More
S&F, HP / LP control switch, IN REPLACEMENT, complete.

15

-

-

... More
M&L for Charging refrigerant F-22/R-22 (Mefron/Refron) gas (to be brought by contractor at site from authorised dealer /manufacturer in sealed cylinder of 61 Kgs) in plant after detection/rectification of any leakage in the system by using CO2 gas and flushing the complete system thoroughly with Nitrogen gas, complete all as specified and directed. Note: The cost of Nitrogen/ CO2 gas used for leakage test and pressure tests prior to filling /charging gas F-22/R-22 shall be deemed to be included in the unit rates.

366

-

-

... More
M&L for Charging refrigerant R-407 (Mefron/Refron) gas (to be brought by contractor at site from authorised dealer /manufacturer in sealed cylinder of 45 Kgs) in plant after detection/rectification of any leakage in the system by using CO2 gas and flushing the complete system thoroughly with Nitrogen gas, complete all as specified and directed by Engineer-in-charge. Note:- The cost of Nitrogen/ CO2 gas used for leakage test and pressure tests prior to filling /charging gas R-407 shall be deemed to be included in the unit rates.

360

-

-

... More
S&F, Oil pressure gauge, range 30-0-150 PSI having 100mm dia IN REPLACEMENT complete.

13

-

-

... More
M&L for De-scaling and cleaning with the help of mechanical pump system through well qualified thchnician/mistry for entire chocked water and gas circulatin system like condensor unit, chiller unit, AHU colis and pipes with all chiller and condensor refrigent piping system complete including, condenser (heat exchanger) to cooling tower, circulating concentrated servicing of valves de-scaling by chemical solution (ORISCALE BLASTER) mixed with water in suitable proportion including full filling it on cooling tower system till the time and storage in system minimum 24 hrs their whichever is later and as ordered by EIC, up to completion of deposit/scale is removed on system their after it circulating through pump, cooling tower, water spray assembly and cleaning with suitable size of drill rod, wire brush including connecting all dismantled components in proper position after serving/overhauling /greasing etc including replacement of new one packing seal/gasket of pump and chiller unit/condensor unit, valve etc with 3mm thick an nuts, bolts with washer, and make it leakage proof system and testing on load complete of following capacity / size:-

-

-

-

... More
03 Nos condensing unit UPTO 15 Ton

5

-

-

... More
03 Nos condensing unit above15 Ton to 50 Ton

18

-

-

... More
M&L for Dismantling of GI sheet duct from AHU and cleaning, descaling complete with blower, vaccum unit and dust cleaning equipment. The ceaning of duct to be started from AHU to different branches in different room. All the grill land defusers are to be cleaned before the refixing duly painted with two coats of super enameled paint to GI ducting as per existing the same any material such as nut, bolts, washers, welding grinding etc deemed to be included in the rate, complete all as specified and directed.

100

-

-

... More
M&L for Air duct made out of galvanized sheet 22 gauge, insulated with fiber glass 50 mm thick covered with wire mesh and aluminium foil and providing air grills adjustable type of size 500 mm x 150 mm, spot including MS work for supporting and painting with two coats of synthetic paint IN REPLACEMENT including errecting & testing complete all as specified and directed.

100

-

-

... More
M&L for 150 micron HDPE polythelene film & aluminium foil to exposed AC supply air duct and wrapping wire netting of galvanised steel wire mesh having 0.71 mm dia of wire & size of mesh 25mm & including 20mm thick rendering around the mesh in cement mortar (1:4) complete all as specified.

43

-

-

... More
S&F, MCCB with thermal magnetic release, ICS=ICU=100%, 4 Pole, 415 volts, AC, 25 kA rupturing capacity IN REPLACEMENT complete as following size:-

-

-

-

... More
32 Amp

6

-

-

... More
63 Amp

6

-

-

... More
100 Amp

6

-

-

... More
125 Amp

6

-

-

... More
S&F, MCB SPN 240 volt, 50 HZ, 10 KA rupturing capacity 'C' series IN REPLACEMENT complete as following size:-

-

-

-

... More
6-32 Amp

6

-

-

... More
40 Amp

6

-

-

... More
S&F, Auxiliary contact IN REPLACEMENT complete all as specified.

7

-

-

... More
S&F, Mechenical interlock kit IN REPLACEMENT complete all as specified.

7

-

-

... More
S&F, Over load relay IN REPLACEMENT complete as following range:-

-

-

-

... More
3-5 Amp Make:- L&T cat part No SS94141OOSO or equivalent in Appendix ''B''

5

-

-

... More
9-15 Amp Make:- L&T cat part No SS94142OOBO or equivalent in Appendix ''B''

6

-

-

... More
S&F, Electronic timer ST100 IN REPLACEMENT complete all as specified. Make:- L&T cat part No ST803280000 or equivalent in Appendix ''B''

10

-

-

... More
S&F, Multifunction meter 5 Amp 3 phase 4 wire 240 volt with RS485 (MFM-LCD display with port Nova) IN REPLACEMENT complete all as specified. Make:- L&T cat part No VM30KFC3CRS or equivalent in Appendix ''B''

5

-

-

... More
S&F, Power contactor 3 pole 415volts, confirming to IEC60947-4-1 & IEC60947-4-1 IN REPLACEMENT complete as following size:-

-

-

-

... More
25 Amp Make:- L&T cat part No CS94106 type MNX 9A or equivalent in Appendix ''B''

5

-

-

... More
30 Amp Make:- L&T cat part No CS94108 type MNX 12A or equivalent in Appendix ''B''

5

-

-

... More
S&F, Auxiliary contact block IN REPLACEMENT complete all as specified. Make:- L&T cat part No CS94112 type MNX 4NO or equivalent in Appendix ''B''

10

-

-

... More
S&F, Dry core refrigent gas filter assembly IN REPLACEMENT complete all as specified.

6

-

-

... More
S&F, Fully automatic star delta starter 3 phase, 15 hp capacity IN REPLACEMENT complete. Make:- HAVELLS cat part No IHHASDTB* or equivalent in Appendix ''B''

4

-

-

... More
S&F, DOL starter 3 phase, 7.5 hp capacity IN REPLACEMENT complete. Make:- HAVELLS cat part No IHHDOLMA*E or equivalent in Appendix ''B''

4

-

-

... More
S&F, Suction stop valve 1.5'' with fully assembly IN REPLACEMENT complete.

5

-

-

... More
S&F, Discharge stop valve 1.5'' with fully assembly IN REPLACEMENT complete.

5

-

-

... More
M&L for Dismantling of electric connection form monoblock motor with pump from the existing foundation/location and supply and fixing new one electric monoblock centrifugal type motor with pump set complete 3 Phase 440 Volt as per existing model/size with required cable connection including duly fixed with existing position of system with the help of any method including checking and testing on full load complete pump with motor complete as following capacity:-

-

-

-

2

-

-

2

-

-

... More
7.5 hp

2

-

-

... More
S&F, Hand shut down/butterfly valve as per existing model IN REPLACEMENT complete as following size:-

-

-

-

... More
40mm dia

6

-

-

... More
50mm dia

6

-

-

... More
80mm dia

6

-

-

... More
100/125mm dia

6

-

-

... More
M&L for PVC insulated 4 core unarmoured cable FRLSH multi stranded copper conductor 1100 volt grade IN REPLACEMENT complete as following size:-

-

-

-

... More
6 Sq. mm

100

-

-

... More
10 Sq. mm

100

-

-

... More
M&L for Repair of PCB control panel of chilling unit of package / central unit / hot water generator of any capacity / make including checking the components, replacing damaged components with new one, making the PCB fully functional entire satisfaction of Engineer-in-charge.

9

-

-

... More
M&L for Heating rod of pan type humidifier, 3 phase, capacity 6kw as per existing model / size including cable connection, fixed with existing position of system with the help of any method including checking and testing IN REPLACEMENT complete.

20

-

-

... More
M&L for Heating rod of hot water generator, 3 phase, capacity 7kw as per existing model / size including cable connection, fixed with existing position of system with the help of any method including checking and testing IN REPLACEMENT complete.

25

-

-

... More
M&L for Chiller unit sensor of central type AC plant as per existing model / size including cable connection, fixed with existing position of system with the help of any method including checking and testing IN REPLACEMENT complete.

20

-

-

... More
M&L for Bearing P-205/207 of package type AC plant duly fixed on existing system / make IN REPLACEMENT complete.

22

-

-

... More
M&L for Drayer of package type AC plant fixed on existing system / make IN REPLACEMENT complete.

20

-

-

... More
M&L for PCB along with all accessories as per existing model/sample suitable for cooling tower of central AC plant and duly fixed on existing system by any fixing method and making electrical connection including taking down existing PCB, complete all as specified and directed. Make- Voltas (Packaged type AC plant 3x 11 TR) Engine Model No. ACOPUASC110R407 Sr. No. 000139 PCB Model No:-PACMPDLTW Sr No.34/SAPL-PACL/PNL/2K/23 Location - Signal section AC plant

4

-

-

... More
M&L for PCB along with all accessories as per existing model/sample suitable for cooling tower of central AC plant and duly fixed on existing system by any fixing method and making electrical connection including taking down existing PCB, complete all as specified and directed. Make- Voltas (Packaged type AC plant 3x 8.5 TR) Engine Model No. ACOPUWSC875DR407 Sr. No. D000100 PCB Model No:- PACMPDSINGLE Sr No.233/SAPL-PACI/PNL/2A Location - Bldg No 10 WSA-I AC Plant

4

-

-

... More
NOTE FOR SERAL ITEM 1 to 49 :- Not withstanding with the provision of "Compensation for Delay' envisaged under condition 50 of IAFW-2249, General Conditions of Contracts, additional compensation @ Rs. 500/- day will be charged from contractor in case he fails to make the functional to the entire satisfaction of Engineer-in-Charge within 24 hour of receiving of complaint from the MES regarding non working above items.

-

-

-

... More
Note : Amount of credit for retrieved materials is mentioned in Sch 'A' Section-II of tender documents in pdf form which will be deducted while acceptance of tender offline.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.