Military Engineer Services Tender

If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date1 Jul 2024
Closing Date4 Sep 2024
Tender Amount₹ 45,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L for Fazilka river sand as in sand cushioning to under ground cable including punning down of thickness 180mm sand in layers, complete all as specified and directed by Engineer in Charge.

256

-

-

... More
M&L for brick protection cover of UG cable by old size bricks common burnt clay building bricks sub class `B’ laid dry and flat abutting each other with width equal to length of brick and gap between adjacent brick not exceeding 10mm, complete all as specified and directed by Engineer in Charge.

16.57

-

-

... More
M&L for making bore below the road for crossing the GI pipe light grade 50 mm dia for cable protection and fill the putty on both sides of the GI pipe after crossing the armoured cable to avoid the water inside complete all as specified and directed by Engr-in-charge.

42

-

-

... More
M&L for making bore below the road for crossing the GI pipe light grade 80 mm dia for cable protection and fill the putty on both sides of the GI pipe after crossing the armoured cable to avoid the water inside complete all as specified and directed by Engr-in-charge.

18

-

-

... More
M&L for GI pipe 80 mm dia. , 'light grade', galvanised, with all fitting; laid in trenches complete all as specified and directed by Engineer in Charge.

18

-

-

... More
M&L for GI pipe 50 mm dia. , 'light grade', galvanised, with all fitting; laid in trenches complete all as specified and directed by Engineer in Charge.

62

-

-

... More
M&L for taking down unserviceable LT UG cable any type from trenches and removing the fault and relaying of LT UG cable after rectifing the fault and making cable in serviceable condition of 1100 V grade UG cable of size from 185 to 240 sq mm, 3½ core including relaying of bricks and sand complete all as specified and directed by Engineer in Charge. ( NOTE : Striaght through joints measure and paid seaprately ) NOTE (a) Striaght through joints measure and paid seaprately (b) Excavation, Returning, filling, removal, will be measured and paid separately.

500

-

-

... More
M&L for taking down unserviceable LT UG cable any type from trenches and removing the fault and relaying of LT UG cable after rectifing the fault and making cable in serviceable condition of 1100 V grade UG cable of size from 70 to120 sq mm, 3½ core including relaying of bricks and sand complete all as specified. NOTE (a) Striaght through joints measure and paid seperately. (b) Excavation, Returning, filling, removal, will be measured and paid separately.

500

-

-

... More
M&L for taking down unserviceable LT UG cable any type from trenches and removing the fault and relaying of LT UG cable after rectifing the fault and making cable in serviceable condition of 1100 V grade UG cable of size from10 to 50 sq mm, 2 to 4 core including relaying of bricks and sand complete all as specified NOTE (a) Striaght through joints measure and paid seperately. (b) Excavation, Returning, filling, removal, will be measured and paid separately.

1000

-

-

... More
Taking down LT cable 1100 Volts grade heavy duty UG cable XLPE/PVC of size from 185 to 240 sq mm, 3½ core, complete all as specified and directed by Engineer in Charge.

190

-

-

... More
Taking down LT cable 1100 Volts grade heavy duty UG cable XLPE/PVC of size from 70 to 150 sq mm, 3½ core, complete all as specified and directed by Engineer in Charge.

470

-

-

... More
Taking down LT cable 1100 Volts grade heavy duty UG cable XLPE/PVC of size from 10 to 50 sq mm, 2 to 4 core, complete all as specified and directed by Engineer in Charge.

2220

-

-

... More
Supply , laying , jointing and testing XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 240 Sq mm 3.5 Core with aluminum thimble of same size complete all as specified and directed by Engineer in Charge.

90

-

-

... More
Supply , laying , jointing and testing XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 185 Sq mm 3.5 Core with aluminum thimble of same size complete all as specified and directed by Engineer in Charge.

100

-

-

... More
Supply , laying , jointing and testing XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 120 Sq mm 3.5 Core with aluminum thimble of same size complete all as specified and directed by Engineer in Charge.

120

-

-

... More
Supply , laying , jointing and testing XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 95 Sq mm 3.5 Core with aluminum thimble of same size complete all as specified and directed by Engineer in Charge.

200

-

-

... More
Supply, laying , jointing and testing XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 70 Sq mm 3.5 Core with aluminum thimble of same size complete all as specified and directed by Engineer in Charge.

150

-

-

... More
Supply , laying , jointing and testing XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 50 Sq mm 3.5 Core with aluminum thimble of same size complete all as specified and directed by Engineer in Charge.

250

-

-

... More
Supply , laying , jointing and testing XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 35 Sq mm 3.5 Core with aluminum thimble of same size complete all as specified and directed by Engineer in Charge.

170

-

-

... More
Supply , laying , jointing and testing XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 25 Sq mm 3.5 Core with aluminum thimble of same size complete all as specified and directed by Engineer in Charge.

250

-

-

... More
Supply , laying , jointing and testing XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 25 Sq mm 4.0 Core with aluminum thimble of same size complete all as specified and directed by Engineer in Charge.

100

-

-

... More
Supply , laying , jointing and testing XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 16 Sq mm 4 Core with aluminum thimble of same size complete all as specified and directed by Engineer in Charge.

550

-

-

... More
Supply , laying , jointing and testing XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 10 Sq mm 4 Core with aluminum thimble of same size complete all as specified and directed by Engineer in Charge.

700

-

-

... More
M&L for cable jointing kit for 1100 volts grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 35 to 95 sqmm, complete all as specified and directed by Engineer in Charge.

5

-

-

... More
All As per Item No. 27 above but for cable of size 120 to 150 sqmm, complete all as specified and directed by Engineer in Charge.

5

-

-

... More
All As per Item No. 27 above but for cable of size 185 to 240sqmm, complete all as specified and directed by Engineer in Charge.

4

-

-

... More
M&L for PCC (1:3:6) type C-1 with 20 mm gradded stone aggregate for copping of poles Pedestal (PCC) or any site requirement including dismantling, complete all as specified and directed by Engr in Charge

3

-

-

... More
Supply and fix of MCCB 63 Amps,4 Pole 16/25 KA with thermal magnetic settings by disamantling old one from panel/feeder pillar box all as directed by Engr-in-Charge.

6

-

-

... More
Supply and fix of MCCB 100 Amps,4 Pole 25 KA with thermal magnetic settings by disamantling old one from panel/feeder pillar box all as directed by Engr-in-Charge.

6

-

-

... More
Supply and fix of MCCB 125 Amps,4 Pole 16 Ka with thermal magnetic settings by disamantling old one from panel/feeder pillar box all as directed by Engr-in-Charge.

8

-

-

... More
Supply and fix of MCCB 160 Amps,4 Pole 16 Ka with thermal magnetic settings by disamantling old one from panel/feeder pillar box all as directed by Engr-in-Charge.

2

-

-

... More
Supply and fix of MCCB 200 Amps,4 Pole 25/26KA Ka with thermal magnetic settings by disamantling old one from panel/feeder pillar box all as directed by Engr-in-Charge.

10

-

-

... More
Supply and fix of MCCB 250 Amps,4 Pole 25/26 KAwith thermal magnetisettings by disamantling old one from panel/feeder pillar box all as directed by Engr-in-Charge.

8

-

-

... More
Supply and fix of MCCB 315 Amps,4 Pole 25/35KA with thermal magneti settings by disamantling old one from panel/feeder pillar box all as directed by Engr-in-Charge.

7

-

-

... More
Supply and fix of MCCB 400 Amps,4 Pole 36/37 KA with thermal magneti settings by disamantling old one from panel/feeder pillar box all as directed by Engr-in-Charge.

4

-

-

... More
Supply and fixing in replacement of Aluminium Thimble of size :-

-

-

-

... More
300 Sqmm

6

-

-

... More
240 Sqmm

18

-

-

... More
185 Sqmm

18

-

-

... More
150 Sqmm

18

-

-

... More
120 Sqmm

24

-

-

... More
95 Sqmm,

24

-

-

... More
70 Sqmm

24

-

-

... More
50 Sqmm

30

-

-

... More
35 Sqmm

30

-

-

... More
25 Sqmm

30

-

-

... More
16 Sqmm

30

-

-

... More
10 Sqmm

30

-

-

... More
6 Sqmm

3

-

-

... More
Material and labour for preparation of old steel surfaces including welding work of door,hinges with locking arrangement and applying one coat of synthetic enamel ivory paint/(Smoke grey) to steel LT Panel/bus bar box and junction boxes surface after disconnecting the electrical connections and reconnecting LT cables after painting, complete as specified and directed by Engr-in-Charge.

10

-

-

... More
Supply & fixing in replacement of sheet metal(MS) bus bar box single door,outdoor type weather proof, size 300x300x200mm mounted on ground with iron angles(25x25x4mm). Having alluminium bus bar 4 nos, rated 100amp all as specified & directed by Eng-in-charge.

6

-

-

... More
M&L for servicing of LT panel of any size. Including disconnecting of supply, removing brunt out wires,cable joints, thimbles, MCCB and bus bar Including supply of copper wires, thimbles, rejointing of any size cable with bus bar and mccb properly.cables of damaged PVC insulation will rejoint after removing damaged piece of cable and making new joint, complete all as specified and directed by Engineer in Charge.

10

-

-

... More
Supply, installing testing and commissioning in replacement of factory made and tested (Including CPRI test cetified) indoor type floor mounted LT panel board, cubical type suitable for 415 Volts 3 phase, 4 wire 50Hz, Ac supply system having busbar chamber with insulated AL busbar of rating 1.5 times the incomer MCCB for phase installed on porcelin/SMC insulators. The panel shall be dust and vermin proof IP-64 class protection and made out of 3.15 mm thick CRCA MS sheet and angle iron frame 40x 40x 6mm thick frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coat of red oxide primer, front and back opening type with aproaches for cable entry with double door shutter and locking arrangements including internal wiring with PVC insulated stranded copper conductor cable FRLS IS 694 sheathed 1100V grade of appropriate size comprising of following:- INCOMING- (i) Mains MCCB 4 pole 250 Amps 50 KA with adjustable setting, 415 Volts with breaking capacity 36 KA -01 No. (ii) Digital type voltmeter 0-500 volts and with selector switch-01 No. (iii) Digital Amp meter with CTs & built in selector switch-01 No. (iv) Indication lamp RYB-01 Set. OUTGOING- (i) MCCB 3 pole 100 Amps, 415 Volts with breaking capacity 36 KA -03 No. (ii) MCCB 3 pole 63 Amps, 415 Volts with breaking capacity 25 KA -04 No.

1

-

-

... More
Supply, installing testing and commissioning in replacement of factory made and tested (Including CPRI test cetified) indoor type floor mounted LT panel board, cubical type suitable for 415 Volts 3 phase, 4 wire 50Hz, Ac supply system having busbar chamber with insulated AL busbar of rating 1.5 times the incomer MCCB for phase installed on porcelin/SMC insulators. The panel shall be dust and vermin proof IP-64 class protection and made out of 3.15 mm thick CRCA MS sheet and angle iron frame 40x 40x 6mm thick frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coat of red oxide primer, front and back opening type with aproaches for cable entry with double door shutter and locking arrangements including internal wiring with PVC insulated stranded copper conductor cable FRLS IS 694 sheathed 1100V grade of appropriate size comprising of following :- INCOMING- (i) Mains MCCB 4 pole 250 Amps 50 KA with adjustable setting, 415 Volts with breaking capacity 36 KA. -01 No. (ii) On load Changeover switch panel mounted with all connections - 01 No. (iii) Digital type voltmeter 0-500 volts and with selector switch-01 No. (iv) Digital Amp meter with CTs & built in selector switch-01 No. (v) Indication lamp RYB-01 Set. OUTGOING- (i) MCCB 3 pole 100 Amps,, 415 Volts with breaking capacity 36 KA -04 No. (ii) MCCB 3 pole 63 Amps, 415 Volts with breaking capacity 25 KA -03 No.

2

-

-

... More
Supply and fixing in repair MCB DB TPN 4 Way vertical tupe factory made IP 43 protection class metal double door with Shrouded Neutral Bar & Pan assembly with connecting link complete including one MCCB upto 125A (ii) MCCB 3 pole 63 Amps, 415 Volts with breaking capacity 25 KA.-03 No.

15

-

-

... More
Supply and fixing in repair on load changeover switch 400 amp 4 pole,415 V,50 Hz in sheet steel enclosure for surface mounting with padlocking facility with the connecting accessories complete all as specified and directed by Engineer in Charge.

2

-

-

... More
Supply and fix in repair on load changeover switch 250 amp 4 pole,415 V,50 Hz in sheet steel enclosure for surface mounting with padlocking facility with the connecting accessories complete all as specified and directed by Engineer in Charge.

2

-

-

... More
Supply and fix 800 Amp ACB 4 pole 50KA with Microprocessor Release of manual drawnout type in existing panels with all LT connections by dismantling the old one complete all as specified and directed by Engineer in Charge.

2

-

-

... More
M&L danger notice board/plate of 1.6mm thick mild steel sheet vitreous enameled white with letter, figures and conventional skull and bones in signal red colour and fixed with MS clamps, nuts and bolts of approved size of HT 25 x 20 cm size, complete all as specified and directed by Engineer in Charge.

50

-

-

... More
M &L for Dismantling/disconnection of LT connections from ACB by taking down proper shutdown,opening the ACB (Panel) installed at various locations for servicing ,overhauling all moving contacts,fixed contacts,tripping coil including testing the insulation value of moving and fixed contacts and cleaning the carbon from contact point with petrol etc and greasing oiling the all moving parts including testing all meters/relay such as under voltage relay and servicing,shut trip coil etc including reassembling the ACB including testing after completion of work complete all as specified and directed by Engineer in Charge. Note : Complete servicing and maintenance will be carried out at site only

14

-

-

... More
M& L for Dismantling of old unsv PCC poles of any size /type carefully and removing from site in parts or whole complete all as specified and directed by Engineer in Charge. Note :- All T&P items deemed necessary to carry out dismantling and removing the old PCC pole are included in the overall cost quoted

4

-

-

... More
Supply and fix bracket for street light fitting made out of 40 mm dia GI pipe light grade 1.2 mtr long each bent to required shape & size as directed by EIC & fixed to pole with and including flat iron clamps 02 Nos made out of 32 x 6 mm flat iron including GI nuts, bolts & washer and painting of clamps andstreet light firtting bracket with one coat of red oxide primer, one under coat and one finishiung coat with alumminium paint complete all as specified and directed by Engineer in Charge.

45

-

-

... More
Supply & labour all steel tubular swaged poles type 410-SP-31 (09 mtr long) with mild steel base plate of size 30cmx30cmx6mm thick, welded at bottom and cap finial taper plugs, bolt, nuts and screw as specified and fixed in true vertical position complete.Make of Pole : Riddhi siddhi poles/ Equivalent as approved by GE. Note :- (a) Excavation earth work, foundation concrete shall be measured and paid separately under respective items. (b) Poles shall be painted with two coats of black bituminous paint throughout internally and externally up to planting depth. The remaining portion of the exterior surface shall be painted with two coats of aluminium paint over a coat of red oxide primer (c) Test certificate and purchase vouchers will be submiited .

5

-

-

... More
M & L for earthing with steel earth plate electrode of size 60cm x 60 cm x 6 mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less tha 1.5 mtr deep below normal grund level connected to galvanized iron strip size 32 x 6 mm as earthing lead by means of nuts, bolts and washers of steel after wlding of GIstrip to earth electrode to the full length of earht plate, 40mm dia GI tubing lightgrade protection pipe upto test point, 20mm dia GI watering pipe with funnel and wire mesh, PCC pit 1:3:6 with pit cover ofsize 30x30 cm made of RCC 1:3: with suitable handle, angle iron frame made of angle iron of size 40x40x4m, adequate qty of charcoal dust and salt layers all around the earth plate and filling of vegetables soil to the remaining 10% removal of surplus soil and retruning filling in all as required at site including test point made outof steel plate of size 75x75x6mm fixed to wall all as specified in plate No 3 of SSR Part-I and directed by Engr-In-Charge.

8

-

-

... More
M&L earthing complete with galvanized steel earth plate electrode 600x600x6.3 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level,the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all side and including connected toand including galvanized earth lead wire 4.0 mm dia upto 7.5 mtrs long by means of nuts and bolts, check nuts and washers of GI and connected to earhing test point and earth dolly all as shown in electrical plate No 3 of MES SSR part I and testing on completion including necessary excavation and earth work in any type of soil,PCC(1:3:6)type C1 chamber,pre-cast RCC slab 50mm thic in cement concrete (1:2:4),type B1,reinforced with welded steel wire fabric or XPM,(weight not less than 4 Kg per Sqm) with cast iron frame,funnel with watering pipe 20mm dia medium grade,wire mesh and lugs,GI protection pipe,15mm dia,light grade,7.5 mtr long for protection of earth lead upto test point etc all as specified and as directed.

6

-

-

... More
Supply and fix only ISI marked self adhesive PVC electrical insulation Tape roll of 25 mm wide, 0.125 mm thick and 25 RM length complete all as specified and directed by Engineer in Charge.

100

-

-

... More
M&L for providing walll mounted LED Display board of size 1m x 1m x1 inch madeup with acrylic sheet with aluminium frame all around the acrylic sheet and back with provision of LED display with all connections,wires etc consisting of description and images as finalized by the Engineer-in-Charge in capital letter at the top complete with fixing arrangements to the wall all as specified and directed by Engineer-in-Charge.

8

-

-

... More
Taking down unserviceable street light fitting upto 11 mtrs HPSV/fluorescent light fitting /CFL Fitting/LED Fitting /Flood light fitting of any size from the pole/bldg and kept in safe custody for refixing or for schedule of credit to contractor Note : All T&P I.e., ladder,Tools,Safty glooves etc will be provided by the contractor without any extra cost .

40

-

-

... More
Repair/mantenance of street light/security lights any type flood lights,post op lanterns or any other external light in its position fixed on pole/high mast/building structure or by taking down to round,if required,testing all the components /parts wiring etc. identifying and replacing the defective components wise choke (ballast) electronic driver,igniter,capactor, lamp,lamp holder,connector,connection wire/cables,MCB etc.including refixing the fixing to its original position (if) taken down including repair,aint of street light control timer & junction box all as directed by Engr-in-charge for the period of contract duration from the date of commencement of the work. Note : (i) The rate against the above mentioned items is deemed for cost of labour and allied expenses only. (ii) Cost of electronic driveragainst above maintenance item will be measured and paid seperately under respective item of of schedule. (iii) The contractor's representative will report to concerened JE E/M at 0900 hrs daily to collect the list of defective street light fitting one will submit the completion report on the same day before 1730 hrs to JE E/M. (iv) The contractor has to rectify the defects/reports and make the street light servicable with in 24 hours from time the list of defective street lights is handed over to him/her rep by the concerened JE E/M.In case the street light is not made functional for whatsever reason with in the specified time line,an amount of Rs. 50per such defective street light per day will recovered from the amount due to him through RAR /Final Bill.The contractor shall be carry out repair/maint will simentanously both domestic & tech area by engaging seperate team of electrician/technician in order to ensure properly & timely rectification of defects. (v) The contractor shall maintain sufficient stock of spares/materials required for repair/maint of street light with the concerened JE E/M. Note : Vehicle and T&P will be arrange by the contractor. (vi) The contractor shall be fully responsible for the safety of his men engaged for executing this work and he will provide all requisite safety equipments and clothing to his men and department shall not be responsible for any mishappening/accident/injuryto his men.

330

-

-

... More
Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing along with prismatic polycarbonate modular secondary lens optics with IP 66 ingress protection . 4KV in-built and 10 KV external surge protection with top opening driver cover for easy maintenance with efficacy not less than 120 lm/W heat resistant. The LED driver shall be of isolated type with Costant Current Constant Voltage topology to ensure optimum driving of LEDs. The LED streetlight shall have power factor more than 0.95. The optical compartment shall be covered with heat resistant toughened glass for safety. The LED Street light should be top maintainable for easy maintenance. LED street light shall be of Integral type. complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete all as specified and directed by Engineer-in-charge

65

-

-

... More
Supply and fixing LED street light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing along with prismatic polycarbonate modular secondary lens optics with IP 66 ingress protection . 4KV in-built and 10 KV external surge protection with top opening driver cover for easy maintenance with efficacy not less than 120 lm/W heat resistant. The LED driver shall be of isolated type with Costant Current Constant Voltage topology to ensure optimum driving of LEDs. The LED streetlight shall have power factor more than 0.95. The optical compartment shall be covered with heat resistant toughened glass for safety. The LED Street light should be top maintainable for easy maintenance. LED street light shall be of Integral type. complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete all as specified and directed by Engineer-in-charge

36

-

-

... More
Supply and fixing LED Flood light luminaire 80 watt 230 V AC outdoor type with poly carbonate optics die-cast housing, IP66 ingress protection, 4KV in -built and 10 KV external surge protection. Efficacy 110 Im/W complete suitable for input voltage140 Volt to 280 Volt. The LED flood light shall have power factor more than 0.95 , 50000 L70,CRI70,CCT 5665K ± 355K, THD 10%,IP 66,IK 07, Operating Tempreature -10 degree Celcius to 50 degree Celcius ,Beam Angle 70degree complete all as specified and directed by Engineer-in-charge.

22

-

-

... More
Supply and fixing Flood light luminaire 150 watt 230 V AC outdoor type with poly carbonate optics die-cast housing, IP66 ingress protection, 4KV in -built and 10 KV external surge protection. Efficacy 110 Im/W complete suitable for input voltage140 Volt to 280 Volt. The LED flood light shall have power factor more than 0.95 , 50000 L70,CRI70,CCT 5665K ± 355K, THD 10%,IP 66,IK 07, Operating Tempreature -10 degree Celcius to 50 degree Celcius ,Beam Angle 70degree complete all as specified and directed by Engineer-in-charge.

20

-

-

... More
Supply and fixing Flood light luminaire 200 watt 230 V AC outdoor type with poly carbonate optics die-cast housing, IP66 ingress protection, 4KV in -built and 10 KV external surge protection. Efficacy 110 Im/W complete suitable for input voltage140 Volt to 280 Volt. The LED flood light shall have power factor more than 0.95 , 50000 L70,CRI70,CCT 5665K ± 355K, THD 10%,IP 66,IK 07, Operating Tempreature -10 degree Celcius to 50 degree Celcius ,Beam Angle 70degree complete all as specified and directed by Engineer-in-charge. Note for S.No. 60 to 64:- (i) Driver and luminaire of LED fitting shall be of same manufacturer (ii) All T&P ie ladder,Tools,Safty glooves etc will be provided by the contractor without any extra cost to height upto 25 mtr

20

-

-

... More
S&F street light GI pipe bracket 50 mm dia 1.50metre length (ISI marked) light grade bend to shape with two Nos MS clamp duly painted nuts and bolts etc. complete all as specified and directed by Engineer in Charge.

15

-

-

... More
S&F street light GI pipe bracket 25mm dia 1.50metre length (ISI marked) light grade bend to shape with two Nos MS clamp duly painted nuts and bolts etc., complete all as specified and directed by Engineer in Charge.

20

-

-

... More
M&L for time light distribution board switches of capacity 65 amps digitial timer box including- (i) contactor rating 65 amp 3pole/230V,(ii) Digital timer programmable type and (iii) MCB 65 Amp TPN,(iv) copper wiring required for connections (v)selecter switch. The timer box Out Door Type,mounted on GI angle iron frameof size 25x25x4mm grouted in cement concrete,including necessary excavation and earth work,connection of LT UG cable.complete all as specified and directed by Engr in charge.

2

-

-

... More
Supply and fixing automatic street light prewired switch using nature switch for automatic switching of street light based on lux level of nature light.THE SENSOR (NATURE SWITCH) alongwith power contactor for 25 KW 3 phase,MCB pole/wall mountable enclosure made of rust proof electric shock proof terminal proof and FR grade special moulding compound junction box confirming to IP54 with all other accessoried ie lugs cable connedtion etc all as direted at site. Make : Kakatiya Energy systems pvt ltd Model No : SWADEEP-03ED 25KW3P Dual or equivalent to Sine Trac/ Indo Asian/ Havell.

1

-

-

... More
S&F MCBs 240/415 Volts SPN 32 Amps 10 KA finger proof terminal, bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, to be fixed on DB, complete all as specified and direcred by Engineer in charge. (DB will be measured and paid separately under respective items of sch A):-

18

-

-

... More
S&F MCBs 240/415 Volts SP 6 to 32 Amps 10 KA finger proof terminal, bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, to be fixed on DB, complete all as specified and direcred by Engineer in charge. (DB will be measured and paid separately under respective items of sch A):-

15

-

-

... More
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated copper conductor served with an inner sheathing of PVC tape with galvanised steel wire or tape and overall PVC sheathed 2 core 2.5 sq. mm nominal cross section in service connections complete all as specified and directed by Engineer in Charge.

500

-

-

... More
Supply, installing, testing and commissioning factory made LT feeder pillar box Outdoor type platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system all as specified and directed having bus bar installed on DMC/Epoxy insulators. The panel shall be dust and vermin proof, IP-65 class protection and made of 3.15 mm CRCA MS sheet with front opening type with double door shutter and locking arrangement (including provn of lock with 2 keys), powder coated finish (over a coat of red oxide), primer on outside and two coats of red oxide primer on inside surface with TPN aluminium bus bar of rating not less than 200Amps including 1 No MCB SPN 06 Amps on suitable foundation complete all as specified and directed by Engineer in Charge.

5

-

-

... More
Supply and fix PVC Sintex box having aluminium bus bar suitable for street light connections including single pole MCB of rating 6 Amps, 2.5 sqmm copper conductor for connection and fixing arrangement to pole all as specified and directed by Engineer-in charge.

90

-

-

... More
M&L for galvanized steel tubing 15 mm dia medium garde (ISI marked) for protection of cable fixed to pole/walls or laid in floors, road crossing ducts with all necessary fittings and fittings and fixed with clamps, bolts, nuts and washers etc complete all as specified and directed by Engineer-in-charge.

130

-

-

... More
Supply and fixing in repair/replacement of solar street light fittings with integrated 12 Watt LED street light system with solar PV Panel 100 WP, integrated LED fitting with Li-Ion Battery 11.1 V 17 Ah , MPPT based solar charge controller,Motion Sensor and tubular pole of height 5 Mtrs complete all as specified and directed by Engineer-in-charge.

6

-

-

... More
M&L for servicing and maintenance of high mast pulley and GI wire rope system oilling, greasing etc for smooth functioning of the lowering mechanish all as directed and specified by Engineer-in-charge.

2

-

-

... More
M&L for rewinding of 0.5 Hp to 1 HP motor of high mast complete all as specified and directed by Engineer in Charge.

2

-

-

... More
Supply and fix in replacement hot dip galvanized decorative pole 6 m height dual arm light fitting outdoor type including 50 watt decorative luminaire with IP66 rating complete with all connections complete all as specified and directed by Engineer in Charge.

6

-

-

... More
Supply and fix single phase driver for LED street light / flood light of 45 to 60 watt capacity and compatible with existing street light/ flood light any type / any rating all as specified and as directed by Engineer-in-charge

50

-

-

... More
Supply and fix single phase driver for LED street light / flood light of 70 to 120 watt capacity and compatible with existing street light/ flood light any type / any rating all as specified and as directed by Engineer-in-charge

25

-

-

... More
M&L cement concrete in foundation filling and mass concrete type B2 1;2;4 (40mm graded aggregate) complete all as specified and directed by Engineer in Charge.

0.5

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.