Military Engineer Services Tender

If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.

Military Engineer Services - MES Tender

Works
Security and Emergency Services
Eprocure
Opening Date13 Jan 2024
Closing Date29 Jan 2024
Tender Amount₹ 24,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Returning filling, in including spreading ,leveling, watering and well ramming in layers not exc 25 cm each all as required.

126.2

-

-

... More
M & L for good quality dry sand cushioning to under ground electric cable on layer of 8 cm thick before laying the cable and second layer of 15 cm thick after laying the cable all as specified in clause 19.75 of MES Schedule part-I (2009) Note : Sand shall be fined sand as specifed and punned thickness shall be measured and paid.

52.11

-

-

... More
Supply and laying sub class 'B' bricks of old size (230x115x75 mm) or of size locally available , laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engineer-in-Charge

5590

-

-

... More
Laying only old bricks retrieved from item No.8 of any size/type laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engineer-in-Charge

2.5

-

-

... More
Removing existing 1100 volts grade, XLPE/PVC, armoured, electric power cables (heavy duty) with aluminium conductor of sizes 6 Sqmm 4 core to 240 Sqmm 4/3.5 core from trench/ duct/ pipe carefully for identifying the defects and relaying the same after rectification of defects complete all as directed. Note: Earth work ( Excavation, Returning & refilling and removal), sand cushining , cable protection cover, GI protection pipe shall be measured and paid for seperately under respective item of Schedule

400

-

-

... More
Supply and lay cable XLPE insulated armoured heavy duty electric cable with aluminium counductor, 1100 volts grade of crosssectional area 16 Sq mm 2 core.Note: Earth work ( Excavation, Returning & refilling and removal), sand cushining , cable protection cover, GI protection pipe shall be measured and paid for seperately under respective item of Schedule

200

-

-

... More
All as per Item No.9 above but of size 16 x 04 core

200

-

-

... More
All as per Item No.9 above but of size 25 Sqmm 4 core

200

-

-

... More
All as per Item No.9 above but of size 35 Sqmm 3.5 core

150

-

-

... More
All as per Item No.9 bove but of size 50 Sqmm 3.5 core

50

-

-

... More
All as per Item No.9 above but of size 70 Sqmm 3.5 core

50

-

-

... More
All as per Item No.9 above but of size 95 Sqmm 3.5 core

90

-

-

... More
All as per Item No.9 above but of size 120 Sqmm 3.5 core

90

-

-

... More
Material, labour , testing & commissioning of straight through jointing kit, heat shrinkable type suitable for XLPE/ PVC cables of size 6 to 35 Sqmm 3.5/4 core with working voltage 1100 volts .

10

-

-

... More
S&F of Cable jointing kit for 1100 V (Earthed) grade cable for Stright through joint heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 185 sqmm to 300 sqmm complete all as specified and directed Engr-in-Charge.

5

-

-

... More
S&F of Cable jointing kit for 1100 V (Earthed) grade cable for Stright through joint heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 25 sqmm to 50 sqmm complete all as specified and directed Engr-in-Charge.

5

-

-

... More
S&F of Cable jointing kit for 1100 V (Earthed) grade cable for Stright through joint heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 10 sqmm to 16 sqmm complete all as specified and directed Engr-in-Charge.

5

-

-

... More
S&F of Cable jointing kit for 1100 V (Earthed) grade cable for Stright through joint heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 sqmm to150 sqmm complete all as specified and directed Engr-in-Charge.

5

-

-

... More
S&F of Cable jointing kit for 1100 V (Earthed) grade cable for INDOOR / OUTDOOR END TERMINATIONS heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 sqmm to150 sqmm complete all as specified and directed Engr-in-Charge.

5

-

-

... More
S&F of Cable jointing kit for 1100 V (Earthed) grade cable for INDOOR / OUTDOOR END TERMINATIONS heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 185 sqmm to 300 sqmm complete all as specified and directed Engr-in-Charge.

5

-

-

... More
M&L for GI pipe light grade 40 mm dia for cable protection on road crossings /plinth protection with fixed to the pole wall etc. suitable fittings for cable protection .

15

-

-

... More
Taking down defective street light fitting of any size/ type/ capacity from height of pole/walls/ high mast of any location exceeding 7.0 m height for repair work and re-fixing back after repair work including checking, inspecting, testing and commmissioning complete all as directed by Engr-in-Charge. Note:a) The M/L for Items like lamp, electronic drivers,surge protection devices etc shall be measured and paid separately under relevant items here in under this Schedule. b) Necessary tools like ladders & other T&P required etc shall be arranged by the Contractor. c) The rate quoted deemed to be inclusive for minor parts nut bolts, circle clips, clamps etc if any required at site.d) The M/L for repairs to LED panel is not included in the scope and shall be measured and paid separately.

120

-

-

... More
Supply only the following spares suitable for LED street/Flood light fittings of (Frm Item 27 to 30)

-

-

-

... More
Electronic driver potted type IP-65, suitable for 90 to 120 W LED light fitting

20

-

-

... More
Electronic driver potted type IP-65, suitable for 70 to 80 W LED light fitting

30

-

-

... More
Electronic driver potted type IP-65, suitable for 30 to 60 W LED light fitting

35

-

-

... More
Surge protection device of capacity 10 KV suitable for LED light fitting

40

-

-

... More
Taking down old unserviceable security light fittings roadway lumanarie type from any height and S&F LED security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 10000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 100 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items

15

-

-

... More
Taking down old unserviceable security light fittings roadway lumanarie type from any height and S&F LED security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 6000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 60 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items

10

-

-

... More
Taking down old unserviceable security light fittings roadway lumanarie type from any height and S&F LED security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 7200 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 72 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items

10

-

-

... More
Taking down old unserviceable flood light fittings from any height and S&F LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 15000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 150 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed.

5

-

-

... More
Supply & fix replacement decorative path way light lighting LED decorative post top lantern for 360 degree 40 watts 230 volts, 50 HZ, maple shaped in sothing opal/ prismatic finish made up of polycarbonate,including all accessories prewired complete.Note :- (i) Minimum 2 years gaurntee period of LED fittings (ii) Driver shall be IP 66 degree of protection potted seal type. (iii) Power factor more than 0.9

4

-

-

... More
Supply and erect steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-11 (11.0 metres long) all as directed incl dismantling old one. NOTE :- Earth work, Cement concrete in foundation, coping etc will be measured and paid separately under relevant item.

2

-

-

... More
Supply and erect steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.0 metres long) all as directed incl dismantling old one. NOTE :- Earth work, Cement concrete in foundation, coping etc will be measured and paid separately under relevant item.

2

-

-

... More
S&F in repair PVC insulated 3 core 2.5 Sq mm stranded Aluminium conductor cable for connecting OH line/junction box to street light fitting testing and commissioning all as directed.

200

-

-

... More
M&L for PCC 1:4:8 type D2 with 40 mm graded aggregate as in foundation complete.

1.8

-

-

... More
M&L for PCC 1:3:6 type C1 with 20 mm graded aggregate for coping of poles and stay including form work.

1.8

-

-

... More
S&F loop-in/loop-out box of outer size size 250x210x115 mm made out of FRP(Hot moulded type) with weather proof canopy and locking screws along with with 5/6 Amps MCB - 01 No, 50 Amps rated 3 pole connector- 01 Nos, neutral link mounted and Din rail suitable size for mounting MCB/Connector etc complete in the box, duly fixed to to steel tubular/rail/PCC/RCC pole using 25 x 3mm FI clamp, including suitable gland and lugs for connecting cable complete all as directed including dismantling old one.

20

-

-

... More
M & L for disconnecting burnt end or portion of UG Cable, removing the cable from loop including necessary excvation and earth work, relaying and reconnecting the cable by removing burnt portion of cable and preparing fresh terminal for cable of cross sectional area 10 Sqmm 2 core to 95 Sqmm 3.5 core of LT cable to pole, main switch, LT Panel etc complete all as specified and as directed .

10

-

-

... More
Removing existing 1100 volts grade, XLPE/PVC, armoured, electric power cables (heavy duty) with aluminium conductor of sizes 6 Sqmm 4 core to 70 Sqmm 3.5 core from trench/ duct/ pipe carefully for identifying the defects and relaying the same after rectification of defects complete all as directed. Note: Earth work ( Excavation, Returning & refilling and removal), sand cushining , cable protection cover, GI protection pipe shall be measured and paid for seperately under respective item of Schedule.

20

-

-

... More
Supply and Repair/Replacement for 250 AMP MCCB, 4 pole 415 volt, AC 50 Hz, 4 pole, 36 KA with adjustable thermal and magnetic tripping system against over load and short circuit conditions incl neutral adjustment suitable of Existing panel board for replace of unserviseble MCCB complete all as specified and directed.

1

-

-

... More
Supply and Repair/Replacement for 63 AMP MCCB 4 pole 415 volt, AC 50 Hz, 4 pole, 10 KA with adjustable thermal and fixed magnetic setting system against over load and short circuit conditions incl neutral adjustment suitable of Existing panel board for replace of unserviseble MCCB complete all as specified and directed.

1

-

-

... More
Supply and Repair/Replacement for 100 AMP, MCCB 4 pole 415 volt, AC 50 Hz, 4 pole, 25 KA with adjustable thermal and fixed magnetic setting system against over load and short circuit conditions incl neutral adjustment suitable of Existing panel board for replace of unserviseble MCCB complete all as specified and directed.

1

-

-

... More
Supply and Repair/Replacement for 125 AMP, MCCB 4 pole 415 volt, AC 50 Hz, 4 pole, 25 KA with adjustable thermal and fixed magnetic setting system against over load and short circuit conditions incl neutral adjustment suitable of Existing panel board for replace of unserviseble MCCB complete all as specified and directed.

1

-

-

... More
Supply and Repair/Replacement for 800 AMP MCCB, 4 pole 415 volt, AC 50 Hz, 4 pole, 36 KA with adjustable thermal and magnetic tripping system against over load and short circuit conditions incl neutral adjustment suitable of Existing panel board for replace of unserviseble MCCB complete all as specified and directed.

1

-

-

... More
Supply and Repair/Replacement for 400 AMP MCCB, 4 pole 415 volt, AC 50 Hz, 4 pole, 36 KA with adjustable thermal and magnetic tripping system against over load and short circuit conditions incl neutral adjustment suitable of Existing panel board for replace of unserviseble MCCB complete all as specified and directed.

1

-

-

... More
Supply and Repair/Replacement for 200 AMP MCCB, 4 pole 415 volt, AC 50 Hz, 4 pole, 25 KA with adjustable thermal and magnetic tripping system against over load and short circuit conditions incl neutral adjustment suitable of Existing panel board for replace of unserviseble MCCB complete all as specified and directed.

1

-

-

... More
Supply and Repair/Replacement for 160 AMP MCCB, 4 pole 415 volt, AC 50 Hz, 4 pole, 25 KA with adjustable thermal and magnetic tripping system against over load and short circuit conditions incl neutral adjustment suitable of Existing panel board for replace of unserviseble MCCB complete all as specified and directed.

1

-

-

... More
Supply and Repair/Replacement of industrial change over switch gear 200 Amp 415 V Four Pole Off Load Side Handle Operated In Sheet enclosure, Powder Coated, Weather proof conforming to IS: 13947 by connecting the electrical connection and fixing on wall or panel with clamp nut, bolt etc complete all as specified and as directed by Engr-in-Charge.

1

-

-

... More
Supply and Repair/Replacement of industrial change over switch gear 100 Amp 415 V Four Pole Off Load Side Handle Operated In Sheet enclosure, Powder Coated, Weather proof conforming to IS: 13947 by connecting the electrical connection and fixing on wall or panel with clamp nut, bolt etc complete all as specified and as directed by Engr-in-Charge.

1

-

-

... More
Supply and Repair/ Replacement of industrial change over switch gear 400 Amp 415 V Four Pole Off Load Side Handle Operated In Sheet enclosure, Powder Coated, Weather proof conforming to IS: 13947 by connecting the electrical connection and fixing on wall or panel with clamp nut, bolt etc complete all as specified and as directed by Engr-in-Charge.

1

-

-

... More
M & L for preparation of old painted surfaces of 09/11 m long PCC poles incl removing oily/ greasy sports and applying one coat of synthetic enamel paint of black and yellow in alternate strip of 30 cm witdth upto 1.5 mtr height including including applying a coat of white wash on pole cooping and lettering the pole details with white letters/black background etc complete all as directed

250

-

-

... More
M&L for painting to steel tubular pole 9.00/11.0 metre long with one coat of red oxide on pole and two coats of synthetic enamel paint up to 1.20 metre height from ground level in 30 cm alternative black and yellow strips and remaining portion with two coats of aluminium paint complete all as specified and directed by Engineer-in-Charge

60

-

-

... More
M&L for numbering of pole no. Using stensils with two coats of Black round and fonts with white in colour complete all as specified and directed by Engineer-in-Charge.

310

-

-

... More
S&F in repair 3 pole power contactor with coil voltage 230 volt AC of current carring capacity 32 to 40 Amps complete including control wiring thimbles etc complete all as directed.

3

-

-

... More
S & F in repair 3 pole power contactor with coil voltage 230 volt AC of current carring capacity 40 to 100 Amps complete including control wiring thimbles etc complete all as directed.

3

-

-

... More
Supply, Installation and Fixing Outdoor type factory made cubical type fabricated out of 3.00 mm thick CRCA sheet floor mounted with angle iron base frame made of 40x40x6mm thick LT PANEL shall be OEM made out of GRP, Glass-fiber reinforced polyester SMC as per EN 14598-1-UP FR2 material with Protection class IP 54 in accordance with IEC 60529 and Color code RAL 7032 completely dyed in mass and box shall be made out of insulating, slow-burning and self-extinguishing composite (polyester + glass fiber) characterized with resistance to atmospheric agents (UV). Protection class II (EN 61140) when correctly installed on the base and Panel internal size should be not less than 590mm x 800mm x 220 mm. GRP material shall be Anti-corrosive suitable for saline atmosphere and have ambient temperatures of -50°C up to +120°C, Flammability HB 40 a, b (EN 60695-11-10),V-1. Glow wire tested at 960°C/ 3 mm as per EN 60695-2-12. The dimensional stability under heat is more than 200 °C as per ISO 75 – 2 method A . The enclosure is Halogen-free, resistant to termites. GRP cabinet should withstand minimum Di-Electric strength of 130KV/Cm as per IEC 60243-1. The Panel box shall have shall be equipped with GRP handle lock with THREE point locking mechanism and the provision to insert various type of locking cylinders provided to avoid unauthorized access. RoHS Directive (EU) 2015/863 (extension to directive 2011/65/EU),REACH Regulation (EC) no. 1907/2006. The Panel mounted on suitable MS Angle Stand and Copper Bus-bar with Heat Shrinkable Sleeves of capacity 400 Amp, wiring of Panel with suitable size of Copper Conductor Cable, Thimbles, etc. having size of the Panel suitable for fixing the Items/Materials mentioned at here-in-below, complete all as specified and as directed .

1

-

-

... More
All as per item No above hereinbefore but INCOMER: 400 Amp, 4 pole MCCB, 36 KA 415V Adj.Thermal & Magnetic Released Ics=100% with Spreader Links - 01 No, Digital Volt meter 0-500V with inbuilt selector switch - 01 No Digital Amp meter 0-200A with inbuilt selector switch & CT Coils- 01 No Set of LED type indicating lamps - 01 No Copper Bus Bar 400Amp TPN OUTGOINGS: 250 Amp, MCCB TPN 36KA 415 V,Adj.Thermal & Magnetic Released Ics=100% with Spreader Links - 02 Nos. 160 Amp, MCCB TPN 25KA 415 V,Adj.Thermal & Magnetic Released Ics=100% with Spreader Links - 02 Nos. 100 Amp, MCCB TPN 16KA 415 V,Adj.Thermal & Magnetic Released Ics=100% with Spreader Links - 01 Nos.

-

-

-

... More
Dismentling old feeder pillar & Supply, installing, testing and commissioning of LT feeder pillar box factory made cubicle outdoor type, fabricated out of 3.00 mm thick CRCA sheet floor mounted with angle iron base frame made of 40 x 40 x 6mm , 50 cm height, floor mounted duly bolts and nuts grouted, dust and vermine proof, suitable for voltage 415 V 3 Phase 4 wire ,Square copper bus bar Chamber 320 Amp Capacity weather proof, with IP-54 protection, with separate hinge door for each compartment for incoming and outgoing MCCB etc with locking arrangement, with back door openable (Screwed), legs grouted in PCC complete including painting with two coats of epoxy powder paint over a coat of primer complete including supply fixing and making provision of the following :- (a) MCCB 4 pole 415 volts 3 phase 200 Amp 25 KA -01 No (f) LED Indicator RYB -01 Set ( Set of three). Note: The panel shall be as per CPRI certificate. Note : PCC will be measured and paid separately.

1

-

-

... More
S&F in repair Capacitor duty contactor with 1 No Aux contact 230V AC coil voltage suitable for minimum 10 KVAR capacitor.

1

-

-

... More
S&F in repair Double metalised paper and polypropylene technology ( Mixed Dielectric) capacitor cylindrical/box type for power factor correction of 440 V, 50 HZ rated of capacity 3 to 15 KVAR.

20

-

-

... More
S&F in repair Double metalised paper and polypropylene technology ( Mixed Dielectric) capacitor cylindrical/box type for power factor correction of 440 V, 50 HZ rated of capacity 20 to 25 KVAR.

20

-

-

... More
M&L in replacement of existing unserviceable contactor of current carring range 40 A to 100 Amp (AC-3 duty) at different places in APFC panels including required electrical connections with suitable size of single core pvc copper cable & testing all as directed.

2

-

-

... More
M&L in replacement of existing unserviceable contactor of current carring range 25 A to 40 Amp (AC-3 duty) at different places in APFC panels including required electrical connections with suitable size of single core pvc copper cable & testing all as directed.

2

-

-

... More
M&L in replacement of existing unserviceable contactor current carring range 9 A to 18 Amp (AC-3 duty) at different places in APFC panels including required electrical connections with suitable size of single core pvc copper cable & testing all as directed.

2

-

-

... More
M&L in replacement of existing unserviceable MCB 25-40 Amps TPN 415 volts at different places in LT Panels/APFC panels including required electrical connections & testing all as directed.

4

-

-

... More
M&L in replacement of existing unserviceable MCB 32 - 63 Amps TPN 415 volts at different places in LT Panels/APFC panels including required electrical connections & testing all as directed.

9

-

-

... More
S&F in repair APFC relay with inbuilt PF meter suitable for 5A CTR suitable for upto 8 Stage.

1

-

-

... More
S&F in repair APFC relay with inbuilt PF meter suitable for 5A CTR suitable for upto 12 Stage.

1

-

-

... More
M&L for replacement of traffic light & alternate flasher/blinker LED more than 250 CDL & No of LED more than 108/12V solar plate charging current = 500 MA, LED color yellow/Red/Green with battery backup 12V/7.5 Ah 24 Hrs Atonomy, auto on/off function with high & low voltage cut off with dawn dusk function inbuilt and mounting on GI pole 80mm dia making necessary connection with suitable size of 4 sqmm cable.

1

-

-

... More
Supply, install, testing and commissioning Automatic power factor correction (APFC) Panel outdoor type (double door) for capacity 30 KVAR with incoming MCCB of capacity 63 Amps 4 pole (6x5) 3 Phase 415 V & 50 Hz system with MD-XL capacitor and with suitable rated TPN MCCB of 25/35 KA rupturing capacity as incomer for the following capacities duly controlled by auto and manual option with free standing configuration relay , auxilliary contacts , CTS , indicator lamps etc and necessary wiring complete and meter eqpt including necessary PCC 1 : 3 : 6 type C2 using 40 MM graded aggregate foundation for fixing / installing the panel on floor etc complete along with a) Power factor meter - 01 No b) Ammeter - 01 No, Volt meter 0 - 500V - 01 No. c) APFC relay with suitable satge with selector switch, including provn of suitable rated CTs in Main incoming panels & control wiring / flexible copper conductor cable for connecting APFC panel to Main incoming panel etc complete all as speciifed and dierected.

1

-

-

... More
All as per Item No. 74 above but capacity 40 KVAR with incoming MCCB of capacity 80 Amps 4 pole (8x5)

1

-

-

... More
M&L for cleaning of treated water tank of RCC construction and of approx size 3.4x3.4x1.5 m of STP by bailing out the accumulated raw water at the bottom and removing the complete silt/sludge/dirt from the tank and disposing it away from site as directed, scrapping the tank inner walls and bottom with wire brush and cleaning the tank inner walls and bottom with the bleaching powder slurry completely incl applying one coat of white wash to entire tank externally complete all as directed by Engineer-in-Charge. Note: (a) The rate deemed to be inclusive of T&P and transportation required for disposal of sludge/dirt away from the site. (b) The cleaning of tank shall be performed once in three months all as directed .

3

-

-

... More
M & L for carrying out chemical analysis (BOD/COD) test of treated sewer water of STP from Govt authorised laboratory or PBTI lab chandigarh all as per CPCB/PPCB norms as directed and following parameters are to be tested pH, TSS, BOD 3 days, COD, Fecal coliform, etc complete all as speciifed and dierected. Note : The rate quoted is deemed to be inclusive of charges for testing, collection and transportation of water samples in sealed PVC container to test lab complete.

4

-

-

... More
M&L for chlorination of treated sewage water with Sodium hypochiorite solution (Grade-I) as per IS 11673-1992 for treatment at Chlorine contact & treated water tank of STP for maintining residual chlorine all as directed by manufacturers recommendations/ instructions Make: RMCO Sodium hypochlorite solution or equivalent approved make by GE.

950

-

-

... More
M&L for taking out existing any type pumpset/ airblower of following capacity for servicing by disconnecting motor and blower/ pump set, pipe line and removing of all parts like bearing, bushes, impeller, shaft etc cleaning all surfaces and scales/ sludge/ dirt/ formed inside/out side pumpset/blower etc Lubricating/ greasing at proper places and re fixing in position with all serviceable parts with motor incl painting with one coat of anti corrosive paint over red oxide primer and writing MES /SM No and testing and commissioning all as directed by Engr-in-charge.( Note - spares like bearings will be measured and paid separately against supply only)

-

-

-

... More
All as per Item No. 79 above but of size 02 HP to 05 HP

2

-

-

... More
All as per Item No. 79 above but of size 7.5 HP to 10 HP

2

-

-

... More
Supply only ball bearings for following capacity pumpsets/airblower

-

-

-

... More
All as per Item No. 82 above but of size 02 HP to 05 HP

2

-

-

... More
All as per Item No. 82 above but of size 7.5 HP to 10 HP

2

-

-

... More
Dismantling unserviceable valves and Supply, fixing,testing and commissioning of butterfly valves incl cutting, welding etc complete all as directed.

-

-

-

... More
All as per Item No. 85 above but of size 50 mm bore

1

-

-

... More
All as per Item No. 85 above but of size 65 mm bore

1

-

-

... More
All as per Item No. 85 above but of size 80 mm bore

1

-

-

... More
M&L for dismantling the defective induction motor of any make & capacity 2 HP to 15 HP , any duty or any class of insulation from the bed, duly coupled with pump/ compressor, transporting to workshop, removing burnt out winding from stator/ rotor, rewinding with suitable gauge of super enamelled copper wire of approved make and replacing drive end and non drive end bearings, insulation materials, varnishing, heating, re-assembling, testing and commissioning of the following capacities including replacing base frame bolts & nuts complete all as directed. Notes: (i) Motor removed for re-winding shall be overhauled completely and quoted rate is inclusive for the same.

12

-

-

... More
S&F in replacement power contactor 3 pole of current carrying capacity suitable for range 2 HP to 5 HP rated motor with coil operating voltage 230 V/ 415 V AC 50 HZ.

1

-

-

... More
S&F in replacement power contactor 3 pole of current carrying capacity suitable for range 7.5 HP to 10 HP rated motor with coil operating voltage 230 V/ 415 V AC 50 HZ.

1

-

-

... More
S&F in replacement Thermal oveload relay suitable for 2 HP to 5 HP rated motor.

1

-

-

... More
S&F in replacement Thermal oveload relay suitable for 7.5HP to 10 HP rated motor.

1

-

-

... More
S&F in star-delta timer.

1

-

-

... More
Supply only (Calcium based granular disinfectant for water treatment, more stable than Chlorine Gas, and stronger than bleachingpowder, and sodium Hypochlorite) with chlorine content 65 to 70 % , packing in 45 kg drum complete all as specified and directed by Engr-in-Charge.

180

-

-

... More
Supply only stable bleaching power (SBP)(Calcium hypochloride)Grade I,availabilty Chlorine 34 % min,Stability 1/15 Max,moisture 0.3% max etc all as per IS.

20

-

-

... More
Maintenance and servicing of DG set consisting of replacement of fuel filter, air filter and lub oil filter including replacement of eninge oil all as directed and testing on full connected load for the following capacity of DG Sets and any make as per OEM.Note: Engine oil will be measured and paid seperately.

-

-

-

... More
All as per Item No. 97 above but DG Set upto 50 KVA

1

-

-

... More
All as per Item No. 97 above but DG Set 63.5 to 200 KVA.

1

-

-

... More
All as per Item No. 97 above but DG Set 200 to 400 KVA.

1

-

-

... More
M&L for replecement of existing unservicible Fan Belt and testing complete for the following capacity of DG Sets and any make as per OEM.

-

-

-

... More
All as per Item No. 101 above but DG Set upto 50 KVA

1

-

-

... More
All as per Item No. 101 above but DG Set 63.5 to 200 KVA.

1

-

-

... More
All as per Item No. 101 above but DG Set 200 to 400 KVA.

1

-

-

... More
M & L for replecement of existing unservicible Hose Pipes with clamps and testing complete for the following capacity of DG Sets and any make:-

-

-

-

... More
All as per Item No. 105 above but DG Set upto 50 KVA

1

-

-

... More
All as per Item No. 105 above but DG Set 63.5 to 200 KVA.

1

-

-

... More
All as per Item No. 105 above but DG Set 200 to 400 KVA.

1

-

-

... More
Taking out the old unserviceable radiator from the DG set and taking it to work shop for overhauling & cleaning descaling with restore plus solution, removal of leakage, welding brazing & refixing it duly repaired etc complete all as directed for the following capacity of DG Sets and any make as per OEM.

-

-

-

... More
All as per Item No. 109 above but DG Set upto 50 KVA

1

-

-

... More
All as per Item No. 109 above but DG Set 63.5 to 200 KVA.

1

-

-

... More
All as per Item No. 109 above but DG Set 200 to 400 KVA.

1

-

-

... More
Dismentling of self starter and S&F new self starter 12 V of capacity of OEM make complete all as specified and directed.

1

-

-

... More
M&L for repair and overhauling of unsv dynamo/ alternator 12 V of any capacity DG set including repair/replacement unsv/defective spares such as field coil, armature winding, carbon bushes, clutch bushes and pinion assy complete all as specified and directed.

1

-

-

... More
M&L for repair and overhauling of unsv of battery charger of capacity 24 V including repair/replacement unsv/defective spares such as transformer, rectifier/diode plate, Ammeter, Voltmeter, selector switch, capsule fuse and neon indicator lamp.

1

-

-

... More
S&F in repair AVR with functions to adjust generator output voltage, prevent voltage hunting, set under frequency roll off knee point, set generator droop to 5% at full load, match AVR input to accessory output, set the over excitation cut off level, set intial frequency related voltage dip, over-voltage protection cut off level, maximum short circuit current with sensing input voltage range 170 - 250 V AC max, 50 -60 HZ frequency with output max upto 120 V DC, continuous current 2.7A & transient 6A for 10 sec including necessary control wiring complete from alternator to AVR complete testing & commissioning for DG sets of capacity upto 63.5 KVA.

1

-

-

... More
All as per srl item No. 116 above but for DG set capacity 63.5 to 200 KVA

1

-

-

... More
All as per srl item No. 116 above but for DG set capacity 200 to 400 KVA

1

-

-

... More
M&L for repair of Water pump of capacity upto 200 KVA DG set including replacement of defective unsv spare part of any make and model and refix the same after repair complete all as specified and as directed

1

-

-

... More
All as per srl item No. 119 above but for DG set capacity 200 to 400 KVA

1

-

-

... More
M&L for Calibration of Fuel pump including replacement of unsv/defective spares of capacity upto 200 KVA DG Set of any make and model complete all as directed.

1

-

-

... More
All as per srl item No. 121 above but for DG set capacity 200 to 400 KVA

1

-

-

... More
M&L for overhauling and calliberation of fuel injector assembly including replacement of unsv/defective spares of capacity upto 200 KVA DG Set of any make and model complete all as directed.

1

-

-

... More
All as per srl item No. 123 above but for DG set capacity 200 to 400 KVA

1

-

-

... More
S&F in replacement battery leads set, PVC insulated multisranded, copper conductor of min size 35 sqmm 1 mtr long each duly fixed with brass clamps, copper lugs suitable for DG sets of different capacities.

2

-

-

... More
M&L for replacement of coolant for radiator for DG set at various locations.Make: Servo/HP/Indian Oil.

20

-

-

... More
M&L for replecement of Lub Oil (Engine Oil) of grade 20W40 for Engine for DG set at various locations.Make: Servo/HP/Indian Oil.

70

-

-

... More
M&L for replacement of starter ring gear assembly for capacity 50 to 110 KVA DG set.

1

-

-

... More
M&L for replecement of existing unservicible oil pressure sensor of any pressure range, any current rating as per site requirement along with other connected accessories complete for the following capacity of DG Sets and any make: :-

-

-

-

... More
All as per srl item No. 129 above but for DG Set upto 50 KVA

1

-

-

... More
All as per srl item No. 129 above but for DG Set 63.5 to 200 KVA.

1

-

-

... More
All as per srl item No. 129 above but for DG Set 200 to 400 KVA.

1

-

-

... More
M&L for maintenance /repairs or periodical check with skilled crane repair to all component of EOT crane 2 Ton capacity including limit switches vertical and horizontal motion and longitudial motion and load testing, greasing/ lubrication to all movable parts, rail track line of crane, adjustment/ rectification of flexible cable with cable carrier/ replacement of PVC cable carriers, rectification/ tightening of all electrical connections at main EOT panels and connected electrical drive motors, checking and rectification of brake system with replacement of tie rod , replacement of gear oil/ replacements of gasket/oil seal and required nut and bolts checking/rectification of portable/ pendent control panel and checking/rectification of cranes light points for smooth functioning and cleaning and dusting of all components for 3 time in each month complete all as specified and directed. Note-(i) All spares parts/ item/stores reuired for replacement shall be measured and saperately as respective sch 'A' ser items. (ii) Srl item No 1 in above labour only charges has been considered.

2

-

-

... More
All as per Srl item No 133 above but for 5 Ton capacity crane

2

-

-

... More
All as per Srl item No 133 above but for 15 Ton capacity crane

2

-

-

... More
S&F in Replacement of Lever Type Limit Switch 2 Way Type LS /2SH2 in IP54 enclosure with two Contacts for 2 ton to 15 Ton crane complete all as specified and directed.

1

-

-

... More
S&F in Replacement of Rotary Type Limit Switch Gear Ratio 48:1 with 2 N.O.+2 N.C. Contact in IP54 Enclosure all is Directed .

1

-

-

... More
S&F in replacement of electromagnetic break 200 mm 415 V AC supply for hoist motion complete all as specified and directed .

1

-

-

... More
S&F in Replacement of Electro hydraulic thruster operated brake suitable for hoisting motion/cross travel motion for crane 2 to 15 Ton crane, 415V, AC supply complete all as Directed .

1

-

-

... More
S&F in Replacement of Electro hydraulic thruster operated brake suitable for long travel motion for crane 2 to 15 Ton crane, 415V, AC supply complete all as Directed .

1

-

-

... More
S&F in Replacement of Electro Hydraulic Thruster Break shoe 250 mm and 18 Kg for Hoist Motion/cross travel motion all as Directed.

5

-

-

... More
S&F in Replacement of Electro Hydraulic Thruster Break shoe 250 mm & 18 Kg for long travel motion all as Directed .

5

-

-

... More
M&L for repairing of Helical Gear Box for Hoist Motion Horizontal Type opening and removing Hoist Gear Box Top Cover by unscrewing Nut Bolts , side shaft plates etc & replacement of damage oil Seal , gaskets of suitable size and replacement of gear oil after washing flushing & cleaning gear Box Chamber completely by kerosene oil,and refixing the same as directed. Note : (Gear oill will be measured & Paid separately)

2

-

-

... More
M&L for repairing of Helical Gear Box of L.T. & C.T. Motion Vertical Type for 2 ton to 15 ton crane and opening and removing of LT & CT Box Top Cover by unscrewing Nut Bolts , side shaft plates etc. Replacement of Damage Oil Seal , Gaskets of Suitable size and replacement of Gear Oil after washing flushing & cleaning Gear Box chamber completely by kerosene Oil and refixing the same as directed. Note :( Gear oil will be measured & paid separately).

2

-

-

... More
S&F in replacement of Heavy duty Resistance Box Naturally Air Cooled Punch steel Grid type suitable for 15 HP Slip Ring Motor RV-260,RA-27.7 4 step 10 Minutes Rating Balance type in M.S.Sheet Enclosure ( Zinc Plated) in well ventilated Housing.

1

-

-

... More
S&F in replacement of Heavy duty Resistance Box Naturally Air Cooled Punch steel Grid type suitable for 3 H.P. SlipRing Motor RV-90,RA-12 3 step 10 Minutes Rating Balance in M.S Sheet Enclosure ( Zinc Plated) in well ventilated Housing.

1

-

-

... More
Supply only Gear Oil complete all as specified and directed.

50

-

-

... More
S&F of stainer wire 6 mm with end bracket 2 Nos for E.O.T Crane End Carriage side welded including cutting welding complete all as specified and directed.

1

-

-

... More
M&L for power contactor 3 pole 23 Amp, 110 volt complete all as specified and directed.

1

-

-

... More
M&L for overload relay 1.0 to 1.4 Amp complete all as specified and directed.

1

-

-

... More
Dismantling/strip opening micro drive box complete with rectifier transformer arrangement, megnatic disc both side coupling for remotting both side ends of driving shaft (gear box coupling side and braking arrangement coupling side) making multi key arrangement on both the shaft and coupling (Teeth system) to avoid any kind of play in coupling and shaft including replacement of 04 Nos carbon bushes, replacement of o2 Nos gun metal bushes including making oiling arrangement in bushes and side covers of bushes/housing of micro drive reassembling/testing complete (crane capacity 2 to 15 Ton) all as specified and directed.

1

-

-

... More
M&L for servicing of Push Button Station 8 way and replacement of unserviciable Push Button with Element.

2

-

-

... More
Dismantling carefully motor electric squirrel cage inductyion type and carrying out rewinding with super enamelled copper windings wire of suitable size so as to provide rated output at rated speed complete including all other winding materials such as leathroid paper,bamboo strips,PVC insulation tape,cotton tape, PVC sleeves,insulation varnish etc complete including assembling testing and comprising of motors of 3 phase 400-440 Volts, 50 cycles/second, 1440 RPM of 5 HP to 15 HP capacities complete all as specified and re-fixing. Note :- ( Quoted rate shall deemed to be included for disconnecting and refixing in position)

20

-

-

... More
M&L for break /compresure oil for EOT crane up to 15 Ton capacity complete all as specified and directed.

30

-

-

... More
M&L for grease for EOT crane up to 15 Ton capacity complete all as specified and directed.

50

-

-

... More
M&L for replacement of flexible coupling suitable perfact allignment beetween motor and driven machine with greasing and replacement of suitable nuts and bolt complete all as specified and directed.

4

-

-

... More
M&L for replacement of tie rod of break system and nut, bolt complete all specified and directed.

4

-

-

... More
S&F in replacement of hoist rope ,which is well suited for high cycle applications like overhead cranes,High breaking load and resistance to bending fatigue and suitable for 2 to 15 ton load carring capacity.

50

-

-

... More
M&L for repairing of wheel for LT and CT of 2 to 15 ton crane and removing bearing Cover by unscrewing Nut Bolts , side shaft plates etc & replacement of gaskets of suitable size and greasing of bearing after washing flushing & cleaning bearing and casing Chamber completely by kerosene oil,and refixing the same as directed. Note : ( greasing will be measured & Paid separately)

5

-

-

... More
M&L for carrying out servicing & maintenance of UPS of capacity 15- 20 KVA by strip opening of UPS, inspection/ servicing of all spare parts such as Drive cards, relay cards, Ac capacitors, inverter cooling fan, ceramic fuses, batteries and including replacing the defective spares if any complete, ressembling, calibration of UPS complete and testing & commissioning complete all as directed. Note : Major Spares such as Inverter Card/ Rectifier Card, AC/DC capacitors, replacement of Batteries required will be measured & paid separately under relevant Schedule. All other spares required for rectifier & inverter section such as other connecting cards, Input fuses, SCR, Inverter cooling fan etc for keeping the UPS in operational state are deemed to be included in the quoted rate.

1

-

-

... More
M&L for carrying out servicing & maintenance of UPS of capacity upto 15 KVA of by strip opening of UPS, inspection/ servicing of all spare parts such as Drive cards, relay cards, Ac capacitors, inverter cooling fan, ceramic fuses, batteries and including replacing the defective spares if any complete, ressembling, calibration of UPS complete and testing & commissioning complete all as directed. Note : Major Spares such as Inverter Card/ Rectifier Card, AC/DC capacitors, replacement of Batteries required will be measured & paid separately under relevant Schedule. All other spares required for rectifier & inverter section such as other connecting cards, Input fuses, SCR, Inverter cooling fan etc for keeping the UPS in operational state are deemed to be included in the quoted rate.

1

-

-

... More
Supply only the following spares for carrying out repairs to UPS of capacity upto 20 KVA of under item No.160 & 161 above :-(From Item 163 to 167)

-

-

-

... More
Inverter card

2

-

-

... More
Rectifier Card

2

-

-

... More
AC capacitor

2

-

-

... More
DC capacitor

2

-

-

... More
12 V 42 AH SMF batteries

20

-

-

... More
S&F in replacement of unsv 4 Pole on load changeover switch of following current carrying capacity 100 Amps including necessary additional/alteration to busbars of existing panel etc complete all as directed.

2

-

-

... More
All as per srl item No.168 above but of capacity 125 Amps Capacity

1

-

-

... More
All as per srl item No.168 above but of capacity 200 Amps Capacity

1

-

-

... More
Taking out U/S control wiring complete from stabilizer of capacity 30 KVA to 100 KVA, 3 phase 415 volts any make for unbalanced load, Providing wiring loom complete to the stabilizers made out of suitable size PVC insulated copper conductor cable including cables lugs, connectors, channels etc. (Note: Additional items required to make stabilizers serviceable will be measured and paid for separately under respective items)

1

-

-

... More
Supply only the following spares for carrying out repairs to voltage stablizer of capacity 30 to 100 KVA.

-

-

-

... More
Voltmeter digital type LED display 50 to 550 Volts,AC supply of size 96x96mm acuracy class 1.0.

3

-

-

... More
Printed control card circuit

2

-

-

... More
Limit switch

2

-

-

... More
Toggle switch 2 way, 5 amps, 230 volts

3

-

-

... More
Synchronous motor single phase AC 230 volts with torque up to 5 Kg/CM all as specified and as directed.

2

-

-

... More
Control transformer with primary voltage 230 volts and secondary voltage any desired voltage between 12 volts to 60 volts to suit the control circuit of the stabilizer

6

-

-

... More
Push button

2

-

-

... More
Variable resistance (pre set) with lock nuts

2

-

-

... More
Resistant for synchronous motor, any rating upto 1K-10 W+10%

2

-

-

... More
Dimmer stat

2

-

-

... More
Brass stud with nut and washers

6

-

-

... More
Carbon brush with Clamp

2

-

-

... More
Testing of dielectric strength of transformer oil for indoor type Stabilizer of capacity 30 kva to 500 kva,433 V, filteration of transformer oil by passing through filtration plant to remove moisture, impurities and improving di-electic strength to above 40 KV for 1 minute including new transformer oil for toping up & testing after filtration complete as specified. (Note: Transformer oil will be measured & paid seperately.)

1000

-

-

... More
Supply and toping of transformer oil with 40KV di-electric strength Transformer and Servo voltage stabilizer .Oil shall conform to IS 335 of 1993. complete all as specified and directed.

150

-

-

... More
Taking out main transformer of the voltage stabilizer of capacity upto 100 KVA for repair/ rewinding. Rewinding of the main transformer using super enameled copper winding wire of existing gauge including latherite paper, PVC sheets, sleeves etc all as required. Varnishing complete with insulating varnish, drying and refixing to the stabilizer after testing all as required at site or directed.

1

-

-

... More
Dismatling, repairing & refixing of of the following damaged/burnt components with new components of 48V DC 150 Amps SMPS power plant including testing complete all as specifed and directed by Engr-in-Charge. (Item No. 189 to 192)

-

-

-

... More
SMPS controller with its daughter cards

1

-

-

... More
48V SMPS modules

3

-

-

... More
Control supply

2

-

-

... More
Surge protection cartridge

4

-

-

... More
Annual Online Recharge of sim card card required in online monitering of parameters of STP, recharge plan should have atleast 2GB data per day, new sim may need to be provided in case old sim stops function for any reason complete all as specifed and directed by Engr-in-Charge.

1

-

-

... More
Supply only Copper thimble(Lugs) of size suitable for connecting cable of size 25 Sqmm to 50 Sqmm complete all as specifed and directed by Engr-in-Charge.

50

-

-

... More
Supply only Copper thimble(Lugs) of size suitable for connecting cable of size 70 Sqmm to 120 Sqmm complete all as specifed and directed by Engr-in-Charge.

50

-

-

... More
Supply only Alumunium thimble(lugs) of size suitable for connecting cable of size 25 Sqmm to 50 Sqmm complete all as specifed and directed by Engr-in-Charge.

150

-

-

... More
Supply only Alumunium thimble(lugs) of size suitable for connecting cable of size 70 Sqmm to 120 Sqmm complete all as specifed and directed by Engr-in-Charge.

200

-

-

... More
Supply only Alumunium thimble(lugs) of size suitable for connecting cable of size 150 Sqmm to 240 Sqmm complete all as specifed and directed by Engr-in-Charge.

50

-

-

... More
Supply only Alumunium thimble(lugs) of size suitable for connecting cable of size 240 Sqmm to 400 Sqmm complete all as specifed and directed by Engr-in-Charge.

20

-

-

... More
Supply and laying of HDPE DWC (Double wall corrugated) pipe of 40 mm bore outer dia laid for protection of cables in trenches, floors complete all as specified and directed.

100

-

-

... More
Supply and laying of HDPE DWC (Double wall corrugated) pipe of 50 mm bore outer dia laid for protection of cables in trenches, floors complete all as specified and directed.

100

-

-

... More
Taking out the old unserviceable battery from the DG Set / SMPS and S&F new 12 V, 180 AH maintenance free battery make Amron/Exide including testing and commissioning complete all as specified and directed.

3

-

-

... More
Note: In case the tenderer quotes different rates for similar item then lowest rate shall only be applicable for payment and contractor shall not have any claim on this account.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.