Military Engineer Services Tender

If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date28 Sep 2024
Closing Date26 Oct 2024
Tender Amount₹ 18,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick soft/disintegrated soil in any type of soil all as specified & directed by Engr-in-Charge.

298

-

-

... More
Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as directed by Engr-in-Charge.

139

-

-

... More
Material and labour for sand cushioning with sand for plaster to under ground cable with a layer of sand 8 cm thick before laying of cable and 15 cm thick after laying of cable and punned down to 10cm complete all as specified and directed by Engineer in Charge. Note : 18 cm thickness shall be reckoned for the purpose of measurement and payment.

131

-

-

... More
Material and labour for brick protection using old size sub class ‘B’ new bricks, laid flat, laid dry with width equal to length of brick, laid across the length of cable complete all as specified and directed.

10.8

-

-

... More
S&F in repair GI pipe light grade of dia 40 mm laying in road and along with poles for cable protection complete all as directed by Engr-in-Charge.

18

-

-

... More
Supply and Laying in repair LT underground cable XLPE insulated armoured heavy duty 1100 Volts grade with aluminium conductor multistranded including centre gland lungs jointing materials etc..laid in trench or fixed it to wall includung connecting testing and commissioning complete for the following sizes:

-

-

-

... More
(a) 10 Sqmm 2 core

500

-

-

... More
(b) 10 Sqmm 4 core

500

-

-

... More
(c) 16 Sqmm 4 core

500

-

-

... More
(d) 25 Sqmm 4 core

300

-

-

... More
Supply & fix in repair PVC sheathed 1100V grade flat 3 core stranded copper conductor of size 2.5 sqmm including conduit pipe connecting from SMC box to street light fitting Complete all as specifed and directed by Eng-in-Charge.

90

-

-

... More
Supply & fix in repair MCB, single pole, 16-32 Amp, 240 Volts, 'C' Curve 10KA including dismantling old one Complete all as specifed and directed by Eng-in-Charge.

100

-

-

... More
Supply & fix in repair MCB, SPN, 32 Amp, 240 Volts, 'C' Curve 10KA including dismantling old one Complete all as specifed and directed by Eng-in-Charge.

40

-

-

... More
Supply & fix in reapair MCB, TPN 40 Amp, 240 Volts, 'C' Curve 10KA including dismantling old one Complete all as specifed and directed by Eng-in-Charge.

8

-

-

... More
Supply & fix in reapair MCB, TPN 63 Amp, 240 Volts, 'C' Curve 10KA including dismantling old one Complete all as specifed and directed by Eng-in-Charge. .

12

-

-

... More
Supply & fix MCB, TPN 100 Amp, 240 Volts, 'C' Curve 10KA including dismantling old one Complete all as specifed and directed by Eng-in-Charge.

3

-

-

... More
S&F in repair, galvanised iron bracket of 'medium grade' pipe 40 mm bore, length 1.20m, bend to required shape with 2 Set clamps made of 40x6mm FI and suitable size of bolts, nuts & washers, etc duly painted with two coats of aluminium paint over a coat of red oxide primer complete for fixing street light fittings all as directed by Engr-in-Charge.

25

-

-

... More
Supply and fix in replacement ; Time light distribution board analog Time switch 230 volt three phase of 16 Amps rating with contactor fixed inside steel enclosure box and fixed to pole/LT Panel including clamps, nuts, bolts and washers etc complete all as specified and directed.Make Indo-Asian cat part No TL016ABO or equivalent in Legrand/Scheneider or equivalent in makes indicated in Appendix 'B' of Particular Specifications complete all as specified and as directed.

2

-

-

... More
Supply, fix, connect and test in replacement, LED flood light fitting 70 Watts capacity having following specification fixture should be having pressure die cast alluminium IP 66 with extended alluminium heat sink with pressure die cast aluminium end caps with seprate control gear unit (b) Fixture should be having PMMA optics for uniform distribution (c) Input voltage 110 V to 300 V AC (d) Surge protection of 5 KV (d) Mechanical protection IK 05 (e) Power factor 0.95 (f) Lumen/watt 105 Lumen/watt (g) THD 10% (h) Fixture front cover with polycarbonate encapsulated (j) Fixture having fuse protection short circuit protection and over voltage protection cutt off voltage 110- 310 V having Auto shutdown mode (k) Fixture should be approved from Govt of India ministry of science & Technology (m) Brand name should be enclosed on fixture (n) LED flood light must be having discute LED Structure Make :Bajaj cat part NoPAR0201004 PCGLF 02 60 or equivalent in makes indicated in Appendix 'B' of Particular Specifications complete all as specified and as directed by Engineer-in-Charge. Note : Contractor shall provide 1 years written manufactures warranty for the LED fixture complete including driver from the certified date of completion.

28

-

-

... More
Supply, fixing and testing in replacement of post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete,

35

-

-

... More
Material and labour for plain cement concrete (1:4:8) type D-2 using 40 mm graded stone aggregates as in foundation bed and around the pole as mass concrete including necessary form work and finishing the exposed surface even and smooth without using extra cement complete all as specified and directed.

4

-

-

... More
Material and labour for plain cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregates for coping around poles,including necessary form work finishing even and smooth without using extra cement all as specified and directed.

10

-

-

... More
Tightening and restringing existing loose/broken conductor (ACSR/Copper)/GI continuous earth wire any type including stringing including replacement of fresh binding wire all as required at site all as directed.

0.5

-

-

... More
Material and labour for boring hole under the road / pavement / hard standing with the help of trenchless technology using ultra sound technique and necessary machine for inserting GI pipe of 100/80 mm bore not less than one meter below ground level complete all as specified and directed. Note : for payment purpose GI Pipe 100/80 mm bore shall be considered.

12

-

-

... More
Supply and fix in replacement; 50 mm bore galvanised iron pipe light grade for cable protection fixed to pole/along wall/floor/under road etc complete all as specified and directed. Note : Clamps nuts & bolts etc shall be measured and paid for separately under appropriate items of sch 'A'

30

-

-

... More
Material and labour for preparation of old painted surface of PCC LT poles and applying two coats of synthetic enamel paint in alteranate black and white strips of 30 cm each up to 1.5 mtr height from top of PCC coping and numbering of poles complete all as specified and directed.

186

-

-

... More
Labour only for cutting/pruning of tree branches 1.5 m all around the LT overhead lines of span n.exc 70 m and around the pole obstruction the overhead line & removing the branches to distance n.exc 50 m to be comlete all as specified and directed.

120

-

-

... More
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick surrounded with charcoal and salt, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m below normal ground level connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanized iron 15 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as directed.The concrete pit shall be PCC 1:3:6 type C-1, 40 mm thick pre cast cover slab of RCC (1:2:4) type B-1 using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I.Item includes cost of 7.50m earth lead wire/strip. Any variation in length shall be adjusted through deviation order. PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate. Item includes the cost of 7.50m GI pipe for protection of earth wire/strip Any variation in length shall be adjusted through deviation order.

10

-

-

... More
Attending and rectification / redressal of day to day complaints of street / security light (HPSV,MH,Flourescent tube light, T-5, LED , Flood light fittings etc. of any make) complaints received through telephone or in person and rectification of defects fixed on street light poles 9/11 m long, building walls, roof by bringing down the fittings on grond or in position including replacement of lamp, ignitor, flexible wire, reflector etc including cleaning of glass/acrylic cover for clear reflection of light, replacement of old unserviceable street light fittings with new fittings etc as required to make the light fitting functional (Vehicle, ladder, tools and takes as required at site for repair/for making light fittings functional shall be provided by the contractor at his own cost and arrangement.Note : (i) Disconnecting electrical connections, opening up for inspection and making joint inventories of defects and spaces to be replaced, re-fixing old serviceable spares and fixing new spares in item replacement reasonbling, installing and fixing against in position testing and commissioning equipment of appliances.(i) Light fitting, ballast, starter, ignitor, diffuser, cable, flexible wire and LED drive etc if required to be replaced in repair shall be measured and paid separetely under relevant item of this BOQ as a supply only

1600

-

-

... More
(ii) Contractor shall deploy sufficient number of electricians and helpers as directed by Engineer-in-charge to attend the complaints and reactify the same within 24 hours of receipt of complaints, failing which a penalty of Rs. 300.00 per complaint shall be imposed on contractor besides payment of complaint shall not be allowed. Attendence record of electrician and helpers shall be maintained jointly by the Engineer-in-Charge and Contractor as well. A pucca bound maintainence register shall also be maintained by the Engineer-in-Charge and Contractor as well. (iii) Contractor's representative shall collect the complaints at complaint cell at 8.30 AM to 9.00 AM from JE E/M and report after completion of rectification of complaints and handover a complaint slip to JE E/M with user signature as a record of attending the complaints for payment purposes. (iv) Old retrived material shall be deposited in AGE E/M yard and will be given to contractor after completion of contract.

-

-

-

... More
(v) Contractor will deposit new material to Engineer in charge for acceptance and then material will be issued by JE E/M daily based on assesment of complaints. (vi) Supply only spares (in replacement) shall be measured and paid for separately under respective items of Schedule 'A'. The unit rate quoted by the contractor in this item shall included for the cost of fixing all types of spares, re-fixing, minor parts such as bolts nuts, washers etc. Purchase vouchers and receipt vouchers shall be attached with the RAR and Final Bill. (vii) Each complaint shall be entered in MB mentioning complaint No, date, location, defects detected, work executed, spares replaced etc in a tabular form in the enlarged MB. (viii) Users signature shall be obtained in token of complete redressal / rectification of a complaint. (ix) Cost of minor repairs, replacement of petty items such as nuts, bolts, washers, screws etc.

-

-

-

... More
All as per item No. 28 but for 16 metres height high mast lights.

38

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.