Military Engineer Services Tender

If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.

Military Engineer Services - MES Tender

Works
Civil And Construction
Civil Works Others
Electrical and Electronics
Electrical Works
Eprocure
Opening Date1 Jul 2024
Closing Date4 Sep 2024
Tender Amount₹ 40,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L in repair MS frame for fixing of panel made out of mild steel angle iron as per site requirement cut to shape, drilled including bending and welding as necessary, reveting, etc.conforming to Fe-290 Gde-E-165 complete all as specified and directed.

4

-

-

... More
M&L in replacement of insulator for fixing the busbar grade 1100 volt, size as per site requirement including nut bolt and washers all as specified and directed.

150

-

-

... More
M&L for rewiring of control panel with 1.5 sq mm multistranded, PVC insulated copper conductor cable between voltmeter, Ammeter and their selector switch complete with CTs all as specified and directed.

15

-

-

... More
M&L for anchor fastner nuts & bolts of mild steel for fixing of panel complete all as specified and directed.

10

-

-

... More
S&F in repair of LED phase indicator lamp set (R,Y,B) operating voltage 220 Volt AC all as specified and directed.

35

-

-

... More
Supply and fixing in repair of selector switch operating Voltage 220 Volt AC all as specified and directed by Engineer -in-charge.

35

-

-

... More
S&F in repair ampere meter 0-200 Amp of size 4"x4" digital type including selector switch all as specified and directed.

35

-

-

... More
S&F in repair of Volt meter 0-500 Volt of size 4"x4" digital type including selector switch all as specified and directed.

35

-

-

... More
M&L for scraping of old paint/rust etc by wire brush from body of LT panel and applying base material/ primer for smooth surface and painting with one coat of synthetic enamel paint to match existing colour complete all as specified and directed.

46

-

-

... More
S & F in repair of Aluminium Bus Bar any Size (5x20, 10x20, 10x40, 10x50,10x80, 10x100 mm as per requirement at site including insulating with sleeves all as specified and directed.

300

-

-

... More
Supplying, installing and commissioning of LT control Bus Bar Chamber, 415 Volts, 50Hz, out door type with neoprene rubber gasket, vermin/dust / weather proof, self ventilation, totally enclosed busbar, front and rear openable with mild steel sliding door bolt 250mm long locking arrangement, made out of 3.00mm thick CRCA sheet duly powder coated, properly welded and connecting the incoming/ out going cables by providing cable glands and cable lugs including taking down existing panel complete all as specified and directed comprising of following accessories:- (i) MCCB 250 Amp 4 pole, 36 KA with adjustable thermal and fixed magnetic setting including spreader. (ii) Bus Bars : 320Amp TPN aluminium busbars. (iii) Volt meter 0 to 500 volts digital type inbuilt selector switch - 1 No (iv) Ampere meter 0 to 200 amp digital type selector switch -01 No.

6

-

-

... More
(v) LED Phase indicator lamp Set of three- 1No. (vi) All connections from MCCBs to bus bar & bus bar to MCCB shall be made with suitable size of aluminium strip, thimbles/ lugs (vii) All accessories prewired with copper conductor cable single core 2.5sqmm multistranded PVC insulated with copper thimbes/ lugs etc. (viii) Frame pedestal legs (4Nos.) made of MS angle of size 40x40x6 mm of length 750 mm, 300 mm below the ground and 450 mm above the gound level, grouted in PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) blocks of suitable size.

-

-

-

... More
Supplying, installing and commissioning of LT out door feeder pillar box double door type with neoprene rubber gasket, vermin/dust / weather proof, 415 Volts, 50Hz, self ventilation on both sides, totally enclosed busbar, fullly comparted type, front openable hinged independent door for each compartment with proper locking arrangement and common front and rear door openable with mild steel sliding door bolt 300mm long locking arrangement, made out of 3.00mm thick CRCA sheet duly powder coated, properly welded and connecting the incoming / out going cables by providing cable glands and cable lugs including taking down existing panel complete all as specified and directed comprising of following accessories:- (i) Incomer: ACB 4 Pole, 415 V, with microprocessor release IPR3+ (LSIG +LCD Display+Thermal Memory+ zone Selectivity+Current & voltage Measurment+Advance Protection+ over temperature protection) 630 Amps 50 KA, Manual Drawout type. (ii) Bus Bars :800A TPN+E aluminium busbars suitable for Outgoing Feeders.

5

-

-

... More
(iii) 4 Nos 250 Amp 4P 36KA Microprocessor MCCB with adjustable thermal and fixed magnetic setting including spreader terminal kit both side. (iv) 01 No 160 Amp 4P 36KA MCCB with adjustable thermal and fixed magnetic setting including spreader terminal kit both side. (v) 04 Nos 10 KVAR capacitor bank connected with 32 Amp MCB SPN separately. (vi) Volt meter 0 to 500 volts digital type inbuilt selector switch = 1 No (vii) Ampere meter 0 to 500 Amp digital type inbuilt selector swtich =1 No (viii) LED Phase indicator lamp Set of three. (ix) All connections from MCCBs to bus bar & bus bar to MCCB shall be made with suitable size of aluminium strip, thimbles/ lugs (x) All accessories prewired with copper conductor cable single core 2.5sqmm multistranded PVC insulated with copper thimbes/ lugs etc. (xi) Frame pedestal legs (4Nos.) made of MS angle of size 40x40x6 mm of length 750 mm, 300 mm below the ground and 450 mm above the gound level, grouted in PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) blocks of suitable size.

-

-

-

... More
Supplying, installing and commissioning of LT out door feeder pillar box double door type with neoprene rubber gasket, vermin/dust / weather proof, 415 Volts, 50Hz, self ventilation on both sides, totally enclosed busbar, fullly comparted type, front openable hinged independent door for each compartment with proper locking arrangement and common front and rear door openable with mild steel sliding door bolt 300mm long locking arrangement, made out of 3.00mm thick CRCA sheet duly powder coated, properly welded and connecting the incoming / out going cables by providing cable glands and cable lugs including taking down existing panel complete all as specified and directed comprising of following accessories:- (i) 01x MCCB 350 Amp 4 pole, 36 KA 415 Volt AC with adjustable thermal setting and adjustable magnetic setting with spreader : Incoming (ii) 05x MCCB 100 Amp 3 pole16 KA 415 Volt AC with thermal setting and fix magneticsetting. (iii) Bus Bars : 400A TPN+E aluminium busbars (iii) Volt meter 0 to 500 volts digital type inbuilt selector switch = 1 No (iv) Ampere meter 0 to 200 Amp digital type inbuilt selector swtich - 1 No (v) LED Phase indicator lamp Set of three- 1 No.

5

-

-

... More
(vi) All connections from MCCBs to bus bar & bus bar to MCCB shall be made with suitable size of aluminium strip, thimbles/ lugs cost of which included in the quoted rate of item. (vii) All accessories prewired with copper conductor cable single strand PVC with copper thimble lugs etc all as specified and directed. (viii) Frame pedestal legs (4Nos.) made of MS angle of size 40x40x6 mm of length 750 mm, 300 mm below the ground and 450 mm above the gound level, grouted in PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) blocks of suitable size.

-

-

-

... More
S&F in repair of ACB 4 Pole, 415 V, with microprocessor release IPR3+ (LSIG +LCD Display+Thermal Memory+ zone Selectivity+Current & voltage Measurment+Advance Protection+over temperature protection) capacity 630 Amp 50KA, Manual Drawout type in existing panel (Make Havells/ L&T/ Legrand/ Schnelder).

3

-

-

... More
M&L earthing complete with galvanised steel earth plate electrode 60×60cm×6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron 25x4mm earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 connected to earthing test point including testing on completion including watering GI pipe 20mm bore medium grade, 15mm bore light grade GI pipe for protection of earth lead including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 54 cm x 54 cm x 5 cm including 8mm dia TMT bars both ways @ 15cm centre to centre with one handle for lifting made out of 8mm dia MS bar, funnel & wire mesh, excavation and earth work in any type of soil complete including dismantling existing all as specified & directed by Engr-in-charge.

40

-

-

... More
Taking out, dismantling the Servo stablizer from foundation and transporting the same to workshop , taking out of all burnt winding wires by strip opening of 3 phase voltage stablizer of any make , rewinding the stablizer with super enameled copper winding wire of required gauge and quantity including varnishing insulation sheet, cotton, glass sleave etc as required reassembling testing transporting back to site from workshop installing back and making connection and again testing for 100 KVA servo voltagestabillizer for improved performance all as specified and directed by Engineer-in-charge . Note : Supply only winding wire and M&L oil shall be measured and paid separately under relevant items.

2

-

-

... More
All as per item No 21 but capacity 25 KVA complete

2

-

-

... More
S&F in repair of off load change over switch 4 pole Knife type capacity 250 Amp, 415 Volt AC with sheet steel enclosure with side handle complete all as specified and directed.

2

-

-

... More
S&F in repair of copper spreader terminal Kit for 2 sides of MCCB capacity 100 Amp 4 pole any make as per existing MCCB at site complete all as specified and directed.

160

-

-

... More
All as per Srl item No 22 above but size 125 to 200 Amp

160

-

-

... More
All as per Srl item No 22 above but size 250 to 250 Amp

130

-

-

... More
All as per Srl item No 22 above but size 315 to 400 Amp

120

-

-

... More
M &L for Repair and comprehensive maintenance of Air Circuit breaker of any make and any capacity by disconnecting the breaker from existing position and detecting the fault, commossioning, replacement of the following defective parts with new ones :- (a) Tripping coil, spring holder. (b) Push buttom. (c) Contactor. (d) Trip coil Supervision (e) Aux switch (f) UVT Coil (g) Miss Insertion preventer (h) Control terminal protection cover (j) Mechanical interlock etc all as specified and directed by Engineer-in-Charge. Note :- (i) All other Spare parts shall be measured and paid separately under relevant items. (ii) Repairs shall be done within 3days after intimation to contractor by JE/Engr-in-Charge failing which penalty of Rs 1000/- per day will be levied on contractor.

5

-

-

... More
S&F in repair of spring charge greared Motor as per sample of existing in site all as specified and directed by Engr-in-charge.

5

-

-

... More
S&F in repair of Closing coil as per sample of existing in site all as specified and directed by Engr-in-charge.

3

-

-

... More
S&F in repair of Phase insulation Barrier as per sample of existing in site all as specified and directed by Engr-in-charge.

2

-

-

... More
S&F in repair of mechanism system as per sample of existing in site all as specified and directed by Engr-in-charge.

2

-

-

... More
S&F in repair of condenser Trip Device (CTD) Unit as per sample of existing in site all as specified and directed by Engr-in-charge.

2

-

-

... More
S&F in repair of test jumper as per sample of existing in site all as specified and directed by Engr-in-charge.

2

-

-

... More
Supply and fix Alluminium lugs eye type suitable for cable size 240 sq mm including necessary crimping tool including taking down of old one complete all as specified and directed .

150

-

-

... More
All as per Srl item No. 33 but of size 300 sqmm.

152

-

-

... More
All as per Srl item No. 33 but of size 400 sqmm.

100

-

-

... More
M&L in repair Bearing of Rolling Shutter

4

-

-

... More
M&L in repair Retainer and end plate of Rolling Shutter

4

-

-

... More
M&L in repair Rolling Shutter spring of rolling shutter

6

-

-

... More
Supply and fixing in repair flexiboard box for sub-station and pump houses building, of size 1.8mx0.5mx0.3m, outer front frame of board shall be made out of Aluminium angle of size 38mmx 38mmx 3mm, sides and back shall be made of GI sheet 18 gauge thick. The marking/writing of SUB STATION NO/PUMP HOUSE NO will be made out of radium letters and font size will be decided by Engineer in charge. Approximate 15 to 20 letters to be accomodated within the board. The box shall should be provided with two Nos. of LED bulbs of not less than 09 watt with holder and wire for connection at both ends. The electric connection to be given by means of suitable wire size through conduit from the respective sub stations and pump house buildings. The contractor shall provide the holding arrangment on the wall of pump houses/ substation building complete all as directed by Engineer-in-Charge.

20

-

-

... More
M&L for scraping of old paint/ rust etc by wire brush from rolling shutter and painting with one coat of red oxide paint and two quote of enameled synthetic paint to match existing colour etc all as specified and directed by Engr-in-Charge.

455

-

-

... More
S&F in repair MCCB AC 415 volts, 63 Amp rating, breaking capacity of 25 KA, Adjustable thermal and fixed Magnetic with two side spreader thermal kit, 3 Pole, conforming to IEC:60947-II/ IS :13947-II) all as specified and directed. Make :- Havells/ L&T/ Legrand/ Schneider.

45

-

-

... More
S&F in repair MCCB AC 415 volts, 100 Amp rating, breaking capacity of 16 KA, Adjustable thermal and fixed Magnetic with two side spreader thermal kit, 3 Pole, conforming to IEC:60947-II/ IS :13947-II) all as specified and directed. Make :- Havells/ L&T/ Legrand/ Schneider.

41

-

-

... More
S&F in repair MCCB AC 415 volts, 125 Amp rating, breaking capacity of 16 KA, Adjustable thermal and fixed Magnetic with two side spreader thermal kit, 4 Pole, conforming to IEC:60947-II/ IS :13947-II) all as specified and directed. Make :- Havells/ L&T/ Legrand/ Schneider.

41

-

-

... More
S&F in repair MCCB AC 415 volts, 160 Amp rating, breaking capacity of 36 KA, Adjustable thermal and fixed Magnetic with two side spreader thermal kit, 4 Pole, conforming to IEC:60947-II/ IS :13947-II) all as specified and directed. Make :- Havells/ L&T/ Legrand/ Schneider.

34

-

-

... More
S&F in repair MCCB AC 415 volts, 200 Amp rating, breaking capacity of 36 KA, Adjustable thermal and fixed Magnetic with two side spreader thermal kit, 4 Pole, conforming to IEC:60947-II/ IS :13947-II) all as specified and directed. Make :- Havells/ L&T/ Legrand/ Schneider.

22

-

-

... More
S&F in repair MCCB AC 415 volts, 250 Amp rating, breaking capacity of 36 KA, Adjustable thermal and fixed Magnetic with two side spreader thermal kit, 4 Pole, conforming to IEC:60947-II/ IS :13947-II) all as specified and directed. Make :- Havells/ L&T/ Legrand/ Schneider.

24

-

-

... More
S&F in repair MCCB AC 415 volts, 400 Amp rating, breaking capacity of 36 KA, Adjustable thermal and fixed Magnetic with two side spreader thermal kit, 4 Pole, conforming to IEC:60947-II/ IS :13947-II) all as specified and directed. Make :- Havells/ L&T/ Legrand/ Schneider.

18

-

-

... More
A Schedule of Credit for old/unserviceable demolished/dismantled items has been catered for in the tender. The Schedule of Credit is pre-priced by MES. The final amount of the tender shall be arrived at after deducting the total amount of Schedule of Credit from the total amount of BoQ as per General Summary sheet catered for after Schedule of Credit.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.