Military Engineer Services Tender

If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Eprocure
Opening Date13 Oct 2021
Closing Date28 Oct 2021
Tender Amount₹ 5,94,550 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply and fix as in replacement thermostat switch, ISI marked for Geysers of any capacity size type & make etc complete all as specified and directed.

250

-

-

... More
Supply and fix as in replacement indicating lamps 230 volts square/round for Geysers of any capacity size type & make etc complete all as specified and directed.

100

-

-

... More
Supply and fix as in replacement flexible cable conductor 3 core, 2.5 sqmm and connecting electrically to Geysers of any capacity size type & make etc complete all as specified and directed.

100

-

-

... More
Supply and fix as in replacement Geysers inner tank made out of 16 gauge stainless steel sheet for 25 litre capacity Geysers of any type & make etc complete all as specified and directed .

10

-

-

... More
Supply and fix as in replacement Geysers inner tank made out of 16 gauge stainless steel sheet for 50 litre capacity Geysers of any type & make etc complete all as specified and directed .

4

-

-

... More
Supply and fix as in replacement syphon assembly made out of brass with water inlet and outlet, rubber gasket, nuts, bolts and washer of required size for 25 litre Geyser of any size , type , make etc complete all as specified and directed.

10

-

-

... More
Supply and fix as in replacement syphon assembly made out of brass with water inlet and outlet, rubber gasket, nuts, bolts and washer of required size for 50 litre Geyser of any size , type , make etc complete all as specified and directed.

4

-

-

... More
Supply and fix as in replacement outer cover made out of 22 Gauge MS sheet for 25 litre Geyser duly fitted with side cover and bottom cover plates complete painted with one coat of synthetic enamel (white) paint over one coat of red oxide primer after preparing the surface , complete all as specified and directed.

10

-

-

... More
Supply and fix as in replacement outer cover made out of 22 Gauge MS sheet for 50 litre Geyser duly fitted with side cover and bottom cover plates complete painted with one coat of synthetic enamel (white) paint over one coat of red oxide primer after preparing the surface , complete all as specified and directed.

4

-

-

... More
Repair to inner steel/copper tank of any size, type, capacity of geyser by brazing and refixing including connections of water and electric supply complete all as specified and directed

10

-

-

... More
Supply and fix as in replacement PVC Nylon thread connection 45/60 cm long with nut at both ends suitable for 15 mm bore pipe suitable for geyser complete all as specified and directed

170

-

-

... More
Supply and fix as in replacement brass chromium plated connection pipe 450 mm long with two adopter and rubber washers suitable for 15 mm bore pipe suitable for hot water complete all as specified and directed

70

-

-

... More
Supply and filling as in replacement glass wool in Geysers vessel any size capacity complete all as specified and directed

10

-

-

... More
Supply and fix as in replacement non return valve 15mm for geysers all as directed by Engineer-in-Charge.

12

-

-

... More
Stop valve cast copper alloy screwed down high pressure with crutch or butter fly handle screwed both ends for iron pipe of bore 15 complete fixed as in repair all as specified and directed. Make : Seiko/GEM/Kingston/SS

20

-

-

... More
Bib tap cast copper alloy chromium plated, fancy type, with capstain head handle screwed down screwed for iron pipe and fixed fo 15mm bore pipe after taking down of old brass bib tap complete all as specified. Make : Seiko/GEM/Kingston/SS

35

-

-

... More
Supply and fix as in replacement pressure release valve on top of Geysers complete all as specified and directed

10

-

-

... More
M&L for sub main wiring with two single core 4.0 Sqmm PVC insulated and unsheathed FRls ,stranded copper conductor cable drawn through pvc conduit 25 mm dia incl 2.5 Sqmm PVC insulated unsheathed FR stranded copper conductor cable as earth wire all as specified and directed.MAKE:finolex,polycab,havells,gloster.

160

-

-

... More
Supply and fix SPN enclosure with two pin and earth metal plug incl mcb sp 20 amp complete all as specified and directed.

30

-

-

... More
Supply and fix plug top 15 Amp suitable for Geysers of capacity 25/50 ltr complete all as specified and directed

175

-

-

... More
fixing of geyser of capacity 25/35/50 litre incl anchor bolt for fixing of geyser on wall complete all directed.

10

-

-

... More
SECTION-II: REPAIR TO SOLAR WATER HEATING SYSTEM IN OLD & NEW CANTT Attending of day to day Solar Water Heating System complaints taking down, opening up, reassembling, refixing and testing of Solar Water Heating System including replacement of unserviceable parts wherever required at the discretion of the Engr-in- Charge shall be carried out by the contractor for efficient functioning of Solar Water heating System. The cost of material will be measured and paid seperately for replalacement of parts complete all as specified and directed by EIC. Note: (i) Schedule of repair to Solar Water heating System is catered for attending day to day complaints of different items within the prescribed time schedule as decided by the EIC on complaint slip, failure to attend the complaint within the prescribed time shall attract a penalty of Rs 250 per day per complaint. Notes: (ii) Irrespective of weather mentioned in any particular item of schedule 'A' or not the taking down, opening up, reassembling, refixing, transportation for workshop and back and testing of system wherever required at the discretion of the Engr-in- Charge shall be carried out by the contractor at his on expenses for efficient functioning. Cost of these elements shall deemed to be included in the unit rate quoted by the contractor against respective item of this schedule. Note: All repair to Solar water heating system shall be carried out from an authorized person of the manufacturer of the system and proof there of shall be produced to the GE before undertaking repairs. Contractor is advised to visit the site to ascertain the model and manufacturer of system before quoting his rates.

90

-

-

... More
Supply and fix as in replacement electric heating element of 3 KW suitable for thermostat housing of Solar water heater of 200/500 liter as per sample of any size capacity.

35

-

-

... More
Supply and fix as in replacement thermostat switch for Solar water heater of 200-500 litres capacity.

30

-

-

... More
Descaling of solar water heating tank of 200/500 litres capacity.

10

-

-

... More
M&L for brazing/welding to hot water storage tank of solar water heater of 200-500 litre capacity made of stainless steel (IA SI-304) 1.6 mm thick.

5

-

-

... More
Replacement of PVC hose pipe for Solar water heating system 200/500 litres capacity including clamps , washers, bolts etc where-ever required..

40

-

-

... More
Replacement of temperature gauge 0 to 120 degree Centigrade 8" long for 200-500 litres capacity water heater.

10

-

-

... More
Supply and fix as in replacement Galvanized steel water tubing medium grade 20 mm bore screwed joints including all fittings such as elbows union sockets fixed in repairs complete on wall with where required fixed in repairs complete all as specified and directed. Make : TATA/JINDAL/SURYA

40

-

-

... More
Supply and fix as in replacement GI nipple 20mm bore 6''/8"/9'' long for Hot water tank of solar water heating system of capacity 200/500 litres.

45

-

-

... More
M&L for sub main wiring with two single core 6 Sqmm PVC insulated and unsheathed FR ,stranded copper conductor cable drawn through PVC rigid non metallic pvc conduit 25 mm dia incl 4.0 Sqmm PVC insulated unsheathed FR stranded copper conductor cable as earth wire all as specified and directed.

125

-

-

... More
M& L for argon welding of solar heating copper/ iron tank any type, any size of solar geyser including necessary cleaning and necessary connections ,fittings complete all as specified and directed.

10

-

-

... More
M & L for solar flat plate collector with all necessary accessories complete all as specified and directed.

14

-

-

... More
M& L for solar heating tank of size 200 LPD capacity with heat exchanger complete including insulation with glass/rock wool and outercover of specific thickness necessary connections ,fittings complete all as specified and directed.

4

-

-

... More
M& L for solar heating tank of size 500 LPD capacity with heat exchanger complete including insulation with glass/rock wool and outercover of specific thickness necessary connections ,fittings complete all as specified and directed.

2

-

-

... More
Load line distribution board SPN, 2 ways, single door, powder coated sheet metal enclosure fitted with 32 Amps MCB SPN (out going) with adjustable release complete fixed as in repair all as specified. Make : Legrand/ Indo Asian/L&T/Havells

8

-

-

... More
Providing reinforced cement concrete type B-l, 1:2:4 (20 mm graded aggregate) in precast posts, fencing posts, straining or terminal posts, struts etc. for fencing, average sectional area n exc 100 sq. cm, with or without chamfered angles and flat, splayed, rounded or mitred tops as directed and fixed

1

-

-

... More
Supply and fix gate valve cast copper alloy 20mm size complete all as specified and directed

15

-

-

... More
Supply and fix PVC water tank of capacity 500 liter complete all as specified and directed.

4

-

-

... More
Supply and fix PVC water tank of capacity 1000 liter complete all as specified and directed.

2

-

-

... More
Supply and fix PVC float valve of 20 mm size complete with all accessories all directed.

10

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.