Military Engineer Services Tender
... More
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Costs
EMD
₹ 28,400Document Cost
₹ 500Tender Fee
Refer Documents
Summary
Cwe/p-59/2020-21 Provn Of One Single Offr Accn At Certain Unit Under Ge(west) Pathankot
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2020_MES_370225_1Bid Award Id
ViewTender No
CWE/P-59/2020-21Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Lumpsum price worked out by the contractor for Internal electric Supply as listed in Schedule 'A' Part-IV.
1
-
17319.7
... More
Lumpsum price worked out by the contractor for Path Work as listed in Schedule 'A' Part-V.
1
-
21297.35
... More
Lumpsum price worked out by the contractor for as listed in Sewage Disposal Work Schedule 'A' Part-VI.
1
-
61587.58
... More
Lumpsum price worked out by the contractor for Drains Work as listed in Schedule 'A' Part-VII.
1
-
11556.94
... More
Lumpsum price worked out by the contractor for External Electrification work as listed in Schedule 'A' Part-VIII.
1
-
41239.68
... More
M&L Point wiring for light/fan/bell point controlled by one switch with 1.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS with and including 20mm PVC rigid conduit (medium grade) having thickness as per IS code with all fittings and including 1.5sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS as earth continuity conductor connected to common earth dolly including cutting, chiseling for concealed piping and making good disturbed surface area and white wash/colour wash to matching with the existing colour complete all as specfied and directed.
Note : (a) Colour coding is to be maintained (Ph-Red, N-Black, Half -Yellow, Earth- Green) (b) On RCC roof ceiling PVC conduit shall be provided on surface for fan with proper fixing clips all as directed.
27
-
-
... More
All as per item No 9 here-in-before but for call bell point complete all as specified and directed.
1
-
-
... More
All as per item No 9 here-in-before but for one 3 pin socket outlet 5 Amps on the same board with other switches complete all as specified and directed.
2
-
-
... More
All as per item No 9 here-in-before but for 5 pin socket outlet 5 Amps on the independent board complete plate all as specified and directed.
6
-
-
... More
M&L for Point wiring with 2.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS with in and including PVC concealed conduit heavy duty 20 mm dia having thickness not less than 1.8mm with all fittings including 2.5Sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS cable as earth continuity conductor connected to common earth dolly in and including cutting chiseling for concealed piping and making good disturbed surface finishing the surface to match with the existing surface complete all as specfied and directed.
Note : (a) Insulation test of point wiring.
(b) Colour coding is to be maintained (Ph-Red, N-Black, Half -Yellow, Earth- Green) (make of 2.5 & 2.5 Sqmm copper wire).
4
-
-
... More
Supply and fix LED Lamp inverter type 14 watt 230 volts,50 Hz, ,lumen 1400 lm, rated current 35 mA, CRI less than 80, , complete all as specified and directed.
6
-
-
... More
Supply and Fix LED tube light fitting complete 20W with decorative type fitting 4 feet long aluminium extruded housing,IP-20 ,rated voltage 230 V, 50 hz, system wattage 20W +/- 10%, system current less than 102 mA, power factor more than 0.95, system lumen efficiency 100lm/watt,CCT 6500K, CRI more than 80, THD less than 30%, driver efficiency more than 85% complete all accessories prewired and connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core all as required at site or directed.
Notes:
(i) LM79 report from third party (instead of company in house lab) NABL/UL accredited lab (ii) LM 80 report from LED manufacturer
(iii) Test certificates to be submitted before commencement of work/ claiming for payment .
(iv) Warranty certificate for minimum 2 years to be submitted from OEM.
7
-
-
... More
S&F sleek LED mirror light fitting 2 feet long 1x10 W including LED tube 2 feet long having ballast, bipin holder, connector block etc complete all accessories prewired and connecting electrically to ceiling rose usning PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core all as directed by Engr-in-chagre
2
-
-
... More
Supply and fix bldg security light fittings, 25 Watt 5700K, IP66, having pressure die cast housing with toughened glass and individual high power LEDs with secondary optics, prismatic polycarbonate cover complete including GI bracket of size 32mm dia bent to shape having length on less than 1.5 mtr fixing with clamp etc and making connections using cord flexible 3 core copper cable of size 23/.0076 from ceiling rose/PVC connector to light fittings or as directed by Engr-in-Charge.
4
-
-
... More
M & L for 1200 mm Sweep Ceiling Fan, energy saving 5 star rated ( BLDC) type, complete with canopy, blades, down rod, split pin etc complete of approx wattage 50 Watt rated suitable for operation on AC 220-240 V AC, 50 HZ, Air delivery approx 210 cum/min suitable for 5 speed control.
3
-
-
... More
M&L for providing/cutting the round/ square hole of required size and fixing the desired surface as per existing finishing and Suppy and Fix Exhaust fan AC single phase 230/240 volts of size 250 mm sweep steel body with louvre including connecting to ceiling rose all as required or directed including connecting to ceiling rose all as required or directed.Note: Test report and Warranty certificate from OEM for minimum 2 years to be submitted before claiming for payment.
2
-
-
... More
S&F Geyser 25 Ltrs capacity, 230 volts, vertical type , BEE with 5 star rated , SS tank, adjustable knob from 25 degree celcius to 75 degree celcius for vertical mounting bracket, heating element 2 KW, thermostat, ELCB water tubes, fasteners, drain pipe and other standard accessories and safety devices as per manufacturer' s catalouge incl necessay drilling, provn of anchor bolts of suitable size and making electrical connections complete all as directed by Engr-in-charge.
Make: Model "monza-ec" of Havells or equivalent models of Bajaj/ Racold/ Usha Lexus/ Voltas
1
-
-
... More
MCB SPN, 40 Volt, 50 Hz with 10 KA , C curve type breaking capacity rating 6 to 40 Amps all as specified and directed.
6
-
-
... More
MCB SPN, 240 Volt, 50 Hz with 10 KA , C curve type breaking capacity rating 6 to 40 Amps all as specified and directed.
1
-
-
... More
Material and labour earthing complete with galvanized steel earth plate electrode 60cmx60cm and 6 mm thick buried directly in ground (Earth pit not less than 2.25 Mtr deep below normal ground level )with top edge of the plate not less than 1.5 Mtr below normal ground level connecting with galvanized iron GI earth wire 4mm dia by means of bolt nut check nuts and washers of galvanized iron and provision of GI tubing medium grade (ISI marked)of size 15mm for protection of GI earth wire upto test point, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, excavation , earth work in any type of soil, removal of excavated soil and returning filling in all as required at site complete all as specified in plate No 3 of SSR Part-I and all as specified or indicated including testing on completion.NOTE :-Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, RCC cover, funnel with watering pipe, GI earth strip upto 7.5 m long for connecting to test point etc. all as required at site for complete earthing).
1
-
-
... More
Material and labour earthing with steel earth plate electrode of size 600x600x6mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanized iron strip of size 32x6mm as earthing lead by means of nuts, check buts, bolts and washers of galvanised iron and earth lead protected by provision of GI medium grade pipe 40 mm bore including provision of aggregates with 40 mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4Kg/Sqm) and frame of angle iron of size 25x25x6mm with 6mm dia MS bar handle made to shape, GI light grade 20 mm bore pipe for watering of suitable length placed on top edge of earth plate, common salt and charcoal filling, with fixing arrangement, funnel, wire mesh and earth work in any type of soil, returning filling in distance not exceeding 50 mtr and removal of surplus soil complete all as per plate No 3 of SSR-2009 Part-I and connecting to existing earth test point all as specified or indicated including testing on cpmpletion.
1
-
-
... More
S & F unplasticisted PVC drainage pipe 160mm dia type ‘B’ with wall thickness 4mm (min) of pressure rating 4 KN/Sqm laid in tranches and joined with cement solvent including testing complete all as specified
17
-
-
... More
Supply, installing, testing and commissioning of LT feeder pillar box factory made cubical outdoor type, fabricated out of 3.15 mm thick CRCA sheet, dust and vermin proof powder coated, double door type (independant cabin including locking arrangement for each MCCBs, bus bar chamber enclosed) complete suitable for voltage 415 V, 50Hz , AC , weather proof, with IP-65 , internally wired with suitable copper conductor with copper busbar (TPN) - 4 Nos insulated by heat shrinkable sleeves & clips on shrouds for joint busbar shall be designed to withstand a fault level at 415 V, sliding bolt should be fitted for pad locking arrangement and Godrej nav tal pad lock with 3 keys to be provided and specified by Engineerp-in-Charge, having legs 105 cm made out of angle iron base frame 65 x 65 x 6mm , upto 45 cm height grouted in and including PCC 1:3:6 type C1 (using 20mm graded crushed stone aggregate), panel should be 60 cm above ground level and including provn of the following:- Notes: (i) The panel shall be front operated with independent side cable cabin for entry and out going from bottom with cable glands.
(ii) Cost of grounting of panel with PCC 1:3:6 (40mm thick stone aggregate), deemed to be included in the item rate. No extra payment will be made.
(iii) This panel shall be a froont operated with cable entry from the bottom. The fault with standing capacity shall be 50 KA. Earth Bus shall be part of the main feeder pillar.)
1
-
-
... More
(a) Bus bar chamber made out of CRCA sheet openable from front side having copper bus bar of 3 phase and neutral of size not less than 1.5 times the rates capacity of Incomer ACB/MCCBs made out of electrolite copper strip shall be insulated with colour coded hat shrinkable sleeve.
(b) MCCB 100 Amps breaking capacity 25 KA (Incoming) 4 pole, 415 Volts, 3 Phase, 50 Hz-01Nos. (c) MCB 63 Amp with rupturing capacity 10 KA(outgoing) 4 pole , 415 V, 3 phase, 50 Hz -03 Nos.
(d) Digital Ammeter/Voltmeter 0 to 400 Amps with selector switch and suitable range of CTs - 01 Set.
Make : : Siemens(3VL)/Legrand(DPX3)/ABB (TMAX)/Schneider (NSX) (e) Phase indicating lamp (Set of three) - 03 Nos (RYB)
Note : 1. The MCB should have Ics=100% Icu for short circuit breaking capacity of minimum 25 KA as indicated rms at 415 Volts 50 Hz AC. The MCCBs shall have spreader links and barriers as standard feature of manufacturer, Make : Siemns (3VL)/Legrand (DPX3)/ABB (TMAX)/ Schneider (NSX)
-
-
-
... More
M&L for non abrasive paving (rectified endura) cement concrete coloured tiles 300mm x 300mm x10mm thick in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement over & including 15mm screed bed in cement moratr 1:6 to match complete al as specified and directed.
Note:-The texture ,colour ,shade of tiles & laying of tiles to any pattern & any design with one or more colours shall be approved by GE and rates also including in this item for necessary raking circular cutting or notching and waste on tiles.
78
-
-
... More
S & F Electronic Energy meter AC Single Phase Electronic Kwh of rating 5-30A, class 1.0, 240 V, 50 Hz, counter type display with transparent hinge type Box with every fitting complete all as specified and directed by Engr-in-Charge.
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements