Military Engineer Services Tender

... More
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date12 Mar 2025
Closing Date9 Apr 2025
Tender Amount₹ 42,00,000 
Notes
Download

Costs

Summary

Repair/maint Of Lt Infrastructure In Domestic And Technical Area And Repair Maint Of Sewage Motor, Starter Panel And

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Material and labour sand cushioning using dry clean sand for protection of underground cable, consolidated and compacted, complete all as specified and as directed.

272.16

-

-

... More
Material and labour well burnt old size sub Class ‘B’ bricks, laid flat, in trenches for cable protection, complete all as specified and as directed.

30.24

-

-

... More
Taking out following defective cable XLPE/PVC sheathed 1100 volt grade heavy duty armoured with aluminium conductor of any Cross sectional area from trenches, from wall/poles/under floor etc, shifting serviceable cable for relaying and removing the unserviceable cable, complete all as specified and directed. Note : (i) Excavation and earth work shall be measured and paid for separately. (ii) Unit rate of this item is also includes the removal of brick/tile as cable protection, GI pipe and cable joint etc. and nothing extra shall be admissible on this account. (iii) After taking out the cables from the trench, serviceability of cable shall be checked by the contractor in presence of the Engr-in-Charge and nothing extra shall be paid on this account.

4200

-

-

... More
Supply and laying, jointing,testing XLPE insulated, armoured, heavy duty, 1100 Volts grade aluminium conductor cable Cross sectional area 6 Sqmm, 4 core in trenches or fixed to wall / passing through pipe / pole and testing, compete all as specified and directed Note : (i) Excavation & earth work, brick protection and sand cushining shall be measured and paid separately in respective items of BOQ.

500

-

-

... More
All as per item No. 7.00 here-in-before but Cross sectional area 10 sqmm, 2 core.

500

-

-

... More
All as per item No. 7.00 here-in-before but Cross sectional area 10 sqmm, 4 core.

700

-

-

... More
All as per item No. 7.00 here-in-before but Cross sectional area 16 sqmm, 4 core.

400

-

-

... More
All as per item No. 7.00 here-in-before but Cross sectional area 25 sqmm, 4 core.

400

-

-

... More
All as per item No.7.00 here-in-before but Cross sectional area 35 sqmm, 4 core.

350

-

-

... More
All as per item No.7.00 here-in-before but Cross sectional area 50 sqmm, 4 core.

500

-

-

... More
All as per item No.7.00 here-in-before but Cross sectional area 70 sqmm, 4 core.

400

-

-

... More
All as per item No.7.00 here-in-before but Cross sectional area 95 sqmm, 4 core.

300

-

-

... More
All as per item No.7.00 here-in-before but Cross sectional area 185 sqmm, 3.5 core. Note for Sl Item No : 7 to 16 : (i) All existing connections for existing busbar trunk must be reconnected with new arrengements of cables & proposed busbar chambers. The rate for making all necessary connections and testing will be deemed to be included in the quoted rates. (ii) Factory test of the cable shall be carried out in presence of the rep of accepting officer as detailed by Accepting Officer and contractor is required to submit purchase vouchers, e-way bill and test certificates while claiming payment of LT cables. The contractor will arrange the testing at factory premises and cost of the same is deemed to be included in the rates quoted.

150

-

-

... More
Material and labour in replacment for GI pipe 40 mm bore light grade for road crossing / on wall / with pole for cable protection of including cutting chasing of plinth protection or wall for inserting of cable and making good to disturbed surface with PCC 1:2:4, type B-1, using 20mm graded stone aggregate, complete all as specified and directed .

72

-

-

... More
All as per item No 17 above but size 80mm bore.

72

-

-

... More
Material and labour in repair earthing complete with GI earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.50 Mtr below ground level. The earth plate to be connetced with GI earthing strip of size 32mmx6mm thick by means of brazing between GI strip and earth plate min 45 cm in vertical length and GI strip also to be joined by brazing only. The GI earthing strip to be protected by galvanised iron pipe 40 mm bore (medium grade) up to ground level. Earthing shall be include with providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) up to 90 cm all around earth plate further filled with 60 cm thick Tibba sand and 2nd layer with 30 cm of Magnesium sulphate powder (compact thickness ) , 3rd layer with tibba sand up to the ground level. Earthing shall also be include for providing concrete earth pit in PCC (1:3:6) type B-1 (with 20mm graded stone aggregate), 50mm thick precast RCC (1:2:4) cover slab (reinforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work and testing, complete all as specified and directed. Note :- GI Strip upto 7.5 metre is included in this rate, the length beyond 7.5 metre shall be measured and paid seperately under respective items.

12

-

-

... More
Supply and fix in repairs GI strip 32mm x 6mm in ground / laid in floor / fixed to wall etc, complete all as specified and diredcted. Note :- Excavation and earth work shall be measured and paid separately.

100

-

-

... More
Dismantling and taking out the old stay assembly complete incl demolition of plain cement concrete, complete all as specified and directed. Note :- (i) Unit rate of this item includes to loose/ disconnection the all accessories which are connected to stay assembly.

2

-

-

... More
Material and labour for stay assembly complete with accssories as shown in electrical plate No1 including GI adjustable stay rod of 16 mm dia, GI stay wire of size 7/4 mm including stay clamps, loop type insulators etc, complete all as specified and directed. Note :- Earth work and PCC work shall be measured and paid separately.

2

-

-

... More
Material and labour in repair danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size, complete all as specified and directed.

25

-

-

... More
All as per Item No 23 above but for HT, 25 x 20 cm size.

25

-

-

... More
Material and labour for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation for poles, filling of mass concrete, complete all as specified and as directed.

0.5

-

-

... More
Material and labour for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in coping for old and new poles including form work, complete all as specified and as directed.

3

-

-

... More
Taking down / removing existing damage and bent PCC/Steel poles from site including connections, complete all as specified and directed.

8

-

-

... More
Supply and fixing steel tubular swaged poles type 410 SP-31 (9 meter long) complete with CI base plate and finial taper plug, bolts, nuts and screws as specified type including, two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and as directed.

8

-

-

... More
M&L in replacement of Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm 3 core, complete all as specified and directed.

2

-

-

... More
All as per item Sl No 29 here in before but Cross sectional area 120 sq mm, 3 core.

2

-

-

... More
Supply, jointing and testing in repair 11 KV, 3 core cable end termination joint (heat shrinkable) suitable for 3 core ,11 KV /UG 3 core XLPE armoured aluminium conductor cable of size 95 sqmm 3 core, complete all as specified and directed.

12

-

-

... More
Supply, jointing and testing in repair 11 KV, 3 core cable end termination joint (heat shrinkable) suitable for 3 core ,11 KV /UG 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sqmm 3 core, complete all as specified and directed.

12

-

-

... More
Dismantling of existing ACSR conductor of any size/type from PCC/Steel poles from overhead line, complete all as specified and directed.

1

-

-

... More
Supply, stringing and fixing ACSR conductor of any type/size on existing poles including fixing to insulators with binding wire or aluminium taps, complete all as specified and directed.

1

-

-

... More
Supply and fixing in replacement by removing of melted or brunt terminals / connections of MCCB, 4 pole, 415 Volts, with in existing electric panel and connecting with new connections of following capacities:-

-

-

-

... More
MCCB, 50 KA, 4 pole, 630 Amps

1

-

-

... More
MCCB, 25 KA, 4 pole, 400 Amp

1

-

-

... More
MCCB, 25 KA, 4 pole, 200 Amp

1

-

-

... More
MCCB, 25 KA, 4 pole, 160 Amp

2

-

-

... More
MCCB, 25 KA, 3 pole, 250 Amp

2

-

-

... More
MCCB, 25 KA, 3 pole, 200 Amp

3

-

-

... More
MCCB, 25 KA, 3 pole, 100 Amp

4

-

-

... More
MCCB, 16 KA, 3 pole, 63 Amp

4

-

-

... More
Material and labour for cleaning and preparation of steel surfaces of any existing E/M equipment / LT Panel and applying one coats of synthetic enameled paint, complete all as specified and directed.

50

-

-

... More
Material and labour in repair MS works, cross arms, bracing, support clamps and back plate fabricated out of structural steel sections including nuts, bolts and washers, welding, bending hot or cold, cutting, drilling holes for bolts in any shape or size and including 02 coats of aluminium paint over a coat of red oxide primer, completet all as specified and directed.

1

-

-

... More
M&L for surface dressing not exc 15 cm deep and surrounding area of street light pole/stay and panel boards including cutting and cleaning away grass,bushes,small plant,vegetable shrubs bushes of under roots, complete all as specified and directed.

4000

-

-

... More
Supplying and fixing in replacment of MCCB of 800 Amps, 4 Pole 415 Volt breaking capacity 50 KA , FIXED TM type complete connection with proper size of thimbles, nut bolts etc, complete all as specified and directed.

1

-

-

... More
Material and labour for repair of existing AMF DG set panel complete checking of circuit wiring and replacment of burnt/US spare parts and replacment of burnt circuit wiring and testing at site for smooth functioning of entire system complete all as specified and directed. Note:- Spare parts will be measured and paid seperatly as 'Supply only'.

5

-

-

... More
Supply only contactor MCX-23 cat part No. CS97018 of L&T or equivalent as approved, complete all as specified and directed.

1

-

-

... More
Supply only contactor MCX-22 cat part No. CS97017 of L&T or equivalent as approved, complete all as specified and directed.

1

-

-

... More
Supply only power contactor of cat part No.TC1D8011 C&S make with auxiliary contractor or equivalent as approved, complete all as specified and directed.

1

-

-

... More
Supply only power contactor 115A ofcat part No. LC1FDP115A of C&S make with auxiliary contactor or equivalent as approved, complete all as specified and directed.

1

-

-

... More
Supply only onload change over switch 100 Amps, 4 pole, 415 V, complete all as specified and directed.

2

-

-

... More
Supply only onload change over switch 160 Amps,4 pole ,415 V, complete all as specified and directed.

1

-

-

... More
Material and labour for cleaning of entire cable duct by removing HT/LT cables from the duct, PCC/ iron duct covers removing waste materials including sand , and clean the entire duct and relaying of cables then fillup new sand and cover with existing PCC/Iron duct covers, complete all as specified and directed.

100

-

-

... More
Tracing out fault in 11KV U/G cable with the help of fault tracing machine and rectifying the same with joints as specified and directed to restore the supply, complete all as specified and directed. Note: (i) Jointing kit to be measured and paid separately. (ii) Earth work to be measured and paid separately under respective items of BOQ. (III) All other necessary arrangements suitable for locating the faults is deemed to be included in the quoted rate. (iv) T & P required for the entire job shall be provided by the contractor at his own end and quoted rates is deemed to be included and nothing extra shall be admissible on this account.

6

100

-

... More
Supply only self adhesive PVC electrical Insulation Tape roll of size 1.80 cm X 0.125 mm of length 6.5 metre, complete all as specified and directed.

300

-

-

... More
Supply and laying in repair DWC HDPE pipe of outer dia of 40mm and inner dia 38mm polyethylene (PE) with smooth internal and profiled external surface for non-pressure for underground cable including bends, complete all as specified and directed.

60

-

-

... More
Supply and laying in repair DWC HDPE pipe of outer dia of 50mm polyethylene (PE) with smooth internal and profiled external surface for non-pressure for underground cable including bends complete all as specified and directed .

60

-

-

... More
Supply and laying in repair DWC HDPE pipe of outer dia of 90mm polyethylene (PE) with smooth internal and profiled external surface for non-pressure for underground cable including bends, complete all as specified and directed.

60

-

-

... More
Supply and laying in repair DWC HDPE pipe of outer dia of 120mm polyethylene (PE) with smooth internal and profiled external surface for non-pressure for underground cable including bends complete all as specified and directed.

60

-

-

... More
Supply and fix in repair DWC HDPE coupler of dia of 50mm to 120 mm complete all as specified and directed.

25

-

-

... More
Supply and fixing in repair Single Phase static type Electronic energy meter 10 to 40 Amp switch counter type LCD ISI Certified ISO 2000, IEC1036, IS 13779, totally temper proof with temper and fraud protection. High accuracy and operation at very low load RF meter with smps power supply 90 days load profile with KWH, KVARH lead KW, KVA, Demand, average voltage and average current, complete all as specified and directed.

70

-

-

... More
Supply and fixing in repair three Phase static type Electronic energy meter 10 to 60 Amps with counter type LCD ISI Certified ISO 2000, IEC1036, IS 13779, totally temper proof with temper and fraud protection. High accuracy and operation at very low load RF meter with smps power supply 90 days load profile with KWH, KVARH lead KW, KVA, Demand, average voltage and average current, complete all as specified and directed.

6

-

-

... More
Supply and fixing in repair of contactors for switching of APFC panel suitable for 10 KVAR, complete all as specified and directed.

2

-

-

... More
All as per item No 57 but for 20 KVAR.

2

-

-

... More
All as per item No 57 but for 25 KVAR.

2

-

-

... More
Supply and fix in repair AIPFC (automatic intelligent power factor corrector) micro processor relay including isolation along with MCCB 150/100 amps with 25 KA repurting capacity suitable for 8 ways, complete all as specified and directed.

1

-

-

... More
Supply and fixing in replacment of street light timer with prefabricated box company made, three phase for 8-12 KW light load, 32 Amp per phase comprising of nature switch, suitable capacity contactor and MCB housed in a enclosure and mounted on 40 x 40x 6mm angle iron frame work PCC 1:2:4 (Type-B-1) using 20 mm graded stone aggregate work on ground as in foundation including excavation and earthwork, complete all as specified and directed.

2

-

-

... More
Material and labour for isolating, disconnecting and transporting the Servo voltage stabilizer of any capacity to workshop for repair maint, strip opening of stabilizer for inspection and ascertaining the defects for repair & replacement of unserviceable spare parts, cleaning, servicing all serviceable accessories including reassembling after repair, preparation for painting with two coats of synthetic enamel paint of approved colour and marking SM/MES No., transporting back to site, reinstallation and testing on load, complete all as specified and directed. Note:- Spare parts will be measured and paid seperately as 'Supply only'.

1

-

-

... More
Supply only PCB controller / plate for automatic voltage correction suitable for servo stabilizer of capacity 150 KVA as per existing type and make, complete all as specified and directed.

1

-

-

... More
Supply only control supply transformer suitable for 150 KVA servo voltage stabilizer as per existing type and make, complete all as specified and directed.

1

-

-

... More
Supply only copper dimmer gear set for automatic voltage correction capacity 150KVA servo stabilizer with as per site requirement for type and make, complete all as specified and directed.

1

-

-

... More
Supply only micro limit switch with cam lever complete for servo stabilizer of capacity 150 KVA as per site requirement for type and make, complete all as specified and directed.

1

-

-

... More
Supply only servo motor synchronous type for automatic voltage correction suitable for servo stabilizer of capacity 150 KVA as per site requirement for type and make, complete all as specified and directed.

1

-

-

... More
Supply only Control Transformer heavy duty sutiable for servo stablizer of 150 KVA capacity as per existing make, complete all as specified and directed.

1

-

-

... More
Taking down old burnt out copper winding and replacement of same for stabilizer oil immersed type of capacity 150KVA by using suitable gauge super enamelled copper conductor as per existing winding, complete all as specified and directed.

24

-

-

... More
Supply only insulation transformer oil toping up into voltage stabilizer of different capacity complete with superior quality insulating oil BDV not less than 50 KV, complete all as specified and directed.

250

-

-

... More
Material and labour for boring of road crossing of size 80 mm dia at suitable depth not lss than 1.00 metre by using machinery / equipments complete without damaging the surface for passing pipes / cables etc. including removing excavated soil to a distance not exc 50m, complete all as specified and as directed. Note : (i) Location of boring holes shall be decided by the Engr-in-Charge as per requirement, nothing extra shall be payable on account of variation in length of crossing of road etc. (ii) During boring soil strata may be changed, hence nothing extra shall be paid to the contractor for boring of holes through different strata/different type of soil. Tenderer is hereby advised to keep in mind this aspect while quoting his rates.

80

-

-

... More
Supply in replacement of silica gel complete contains in the breather assembly, complete all as specified and directed.

25

-

-

... More
Supply and fixing in repair cable route indicator for HT UG cable of 11000 Volts bolted with 40x6mm flat iron member of height 0.60m and 80mm dia CI plate, embeded in PCC 1:3:6 type C-2 (Using 20 mm graded stone aggregate) of size 20cm x20cm x 30cm block, complete all as specified and as directed.

70

-

-

... More
M&L for cleaning and preparation of surfaces of any existing E/M equipment / LT Panel and applying one coats of synthetic enameled paint, complete all as specified and directed.

40

-

-

... More
Material and labour for trimming of tree branches on both sides of HT /LT aluminium conductor overhead, complete all as specified and directed. Note : (i) Cutting branches shall be dumped outside the Air Force premises. (ii) Contractor shall be provide the ladder of required height including T&P to his worker and nothing extra shall be paid on this account.

3000

-

-

... More
Supply and fixing in replacment of onload change over switch 630 Amps, 4 pole, 415 Volts in sheet metal enclosure, complete all as specified and directed.

1

-

-

... More
Supply and fixing in replacment of Bus bar assembly 400 Amp, 415 Volts, TPN type, IP 42 protection in sheet metal enclosure, complete all as specified and directed.

3

-

-

... More
Material and labour for cleaning and preparation of steel surfaces of existing dull painting of transformer outdoor type including radiators, cooling ducts, vent pipes, condensor etc and applying two coats of synthetic enameled paint by spray machine including writing MES /SM No(letter size shall be 50 mm size) in capital letters on body for capacity upto 100 KVA transformer outdoor/indoor, complete all as specified and directed.

2

-

-

... More
All as per item No 78 here-in-before but capacity above 160 KVA and upto 630 KVA.

12

-

-

... More
Material and labour for painting of steel tubular pole 9.0 m long/Swan neck pole, by applying two coat of alluminum paint after scraping/brushing and cleaning the rust on pole and cross arms. Aluminium painting will be done on pole above 1.5 m height from ground level and balance 1.5 m from ground level will be painted by alternate layer of red and white synthetic enammelled paint ( 30 cms each) pole No will be written on pole by black paint in yellow circle of 150 mm dia, complete all as specified and directed.

110

-

-

... More
Material and labour for painting with two coats of synthetic enamel paint on RCC pole upto 1.5 mtr above the GL painted by synthetic enamel paint in alternatively black and white strap of 30 cm after scraping /removing the existing paint and the preparation on the surface of RCC LT pole. Pole No will be written on pole by black paint in white circle of 150 mm dia, complete all as specified and directed.

60

-

-

... More
Supply, install, testing and commissioning in repair LT Panel, Outdoor type, CPRI approved dust and vermin proof, totally enclosed, platform mounted, factory made having front openable shutter with locking arrangement made out of CRCA steel sheet, 3.15 mm thick with MS angle iron frame work of size 50 mm x 50 mm x 6 mm 450mm thick, duly Through chemical Treatment with 7 Tank Pre Treatment Process Method for Degreasing ,Derusting and Phosphating Power Coating Siemens grey all as specified including necessary foundation bolts, PCC (1:2:4), type B-1 (using 20 mm graded stone aggregate) platform of suitable size for mounting the panel, suitable for 415 Volts, 50 Hz, three phase, 4 wire system with suitable insulated aluminium busbar of capacity not less than 400 Amps and shall be complete with internal wiring with copper conductor and including the following accessories, complete all specified and directed:- (A) Main Incoming (i) MCCB conforming to IS:13947 (Part-II), IEC-947, 4 pole, 250 Amps, 415 volts, 50 Hz, rupturing capacity 36 KA, with adjustable thermal and adjustable magnetic setting - 02 No. (ii) LED Multifucntional Panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs. (iii) LED indicating lamps with colour Red, Yellow, Blue, Main ON - 01 Set (iv) Spreader Link 250 Amps 4 pole 4 pole 04 Nos, Ct Coils 250/5 Amps

1

-

-

... More
(B) Main Outgoing (i) CCB conforming to IS:13947 (Part-II), IEC-947, 4 pole, 100 Amps, 415 volts, 50 Hz, rupturing capacity 36 KA, with adjustable thermal and fixed magnetic setting - 03 No. (ii) MCCB conforming to IS:13947 (Part-II), IEC-947, SPN 16-32 Amps 4 pole - 02 No. Note - (i) Layout diagram of panel shall be produced by contractor for approval of Accepting Officer before placing order to manufacturer and panel shall be brought at site as per approved drawing. (ii) Contractor is required to submit purchase vouchers, e-way bill and test certificates while claiming payment of LT panels.

-

-

-

... More
Supply, install, testing and commissioning in repair LT Panel, Outdoor type, CPRI Approved dust and vermin proof, totally enclosed, platform mounted, factory made having front openable shutter with locking arrangement made out of CRCA steel sheet 3.15 mm thick with MS angle iron frame work of size 50 mm x 50 mm x 6 mm 450mm thick, duly Through chemical Treatment with 7 Tank Pre Treatment Process Method for Degreasing ,Derusting and Phosphating Power Coating Siemens grey all as specified including necessary foundation bolts, PCC (1:2:4), type B-1 (Using 20mm graded stone aggregate) platform of suitable size for mounting the panel, suitable for 415 Volts, 50 Hz, three phase, 4 wire system with suitable insulated aluminium busbar of capacity not less than 400 Amps and shall be complete with internal wiring with copper conductor and including the following accessories, complete all specified and directed:- (A) Main Incoming (i) MCCB conforming to IS:13947 (Part-II), IEC-947, 4 pole, 630 Amps, 415 volts, 50 Hz, rupturing capacity 36 KA, with adjustable thermal and adjustable magnetic setting - 01 No. (ii) LED Multifucntional Panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs (iii) LED indicating lamps with colour Red, Yellow, Blue, Main ON - 01 Set. (iv) Spreader Link 250 Amps 4 pole 4 pole 04 Nos, Ct Coils 250/5 Amps

1

-

-

... More
(B) Main Outgoing (i) MCCB conforming to IS:13947 (Part-II), IEC-947, 4 pole, 400 Amps, 415 volts, 50 Hz, rupturing capacity 36 KA, with adjustable thermal and fixed magnetic setting - 04 No. Note - (i) Layout diagram of panel shall be produced by contractor for approval of Accepting Officer before placing order to manufacturer and panel shall be brought at site as per approved drawing. (ii) Contractor is required to submit purchase vouchers, e-way bill and test certificates while claiming payment of LT panels.

-

-

-

... More
Material and labour for lifting /lowering/opening /dismantling of Submercible type sewage pump 3 pahse, capacity 7.5/5 HP, including shifiting, transportaion, overhauling shaft, welding / grinding / finishing the spares/body and replacing wornout/damaged parts and minor repair as lifting eye bolt, cable gland, protection tube, cable seal, terminal board, cable bracket, brearing cover, double mechanical seal, tie for stand,support bracket, guide shoe, moisture sensor, potting cup, hose clip, and reassembling, connecting, testing and making serviceable, complete all as specified and as directed. Note:- (i) Spare parts will be measured and paid seperatly as 'Supply only'.

3

-

-

... More
All as per Item No 85 above but for 15 HP 3 Phase. Note:- (i) Approximate copper winding required 12.5 Kg for each motor.

1

-

-

... More
Supply only Ball Bearing.

6

-

-

... More
Supply only Mechnical Seal.

3

-

-

... More
Supply only Non Clog Pump Impeller 15 HP.

1

-

-

... More
Supply only main Lead.

2

-

-

... More
Supply only Wire Seal.

6

-

-

... More
Supply and fixing and connecting in replacement direct on line (DOL) , 415 Volts, 3 phase AC including single phase protection complete suitable for electric motor capacity 15HP, 30 Amps, complete all as specified and as directed.

1

-

-

... More
S&F in repair ML 3 Contractor, complete all as specified and directed.

3

-

-

... More
Material and labour in replacement flat iron clamp 75 cm long of size 100mm x 6mm thick made out of MS, suitable for 80 mm bore GI pipe with complete nuts, bolts and washer etc, complete all as specified and as directed.

3

-

-

... More
Material and labour for cutting and removing the existing rusted flange of column pipe and refixing new flange pipe dia 80 mm including cutting of column pipes threading and welded with 2 Nos heavy duty flange, tee, bend , elbow flanged not less than 12mm thick duly drilled with cable slot, complete all as specified and as directed.

12

-

-

... More
Material and labour in replacement of PVC hose 100 mm dia, heavy duty 6 mm thickness suitable for sunciton/delivery line of sewage motors with connected such as clamp , flange and nut bolt etc, complete all as specified and as directed.

30

-

-

... More
Supply Only First Aid Kit box No-08 (Size 360 mm x 150 mm x 80 mm) containing following items :- (a) Dettols bottle100 ml 02 bottles (b) Antiseptic Ointment 100 mg (c) Crocin tabletes 01 strips ( containings 10 Tablets each). (d) Hydrogen peroxide 50 ml 01 bottle (e) Cotten small rolls 2 Nos (f) Cotten strip small roll 04 Nos (g) Move tube 01 Nos (h) Betadine Tube 100 mg

3

-

-

... More
Supply and fixing in repair mild steel screw bolts (Machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends as per existing and at site required, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 8 cm long, complete all as specified and as directed.

20

-

-

... More
Material and labour for welding of panel door and borken parts, re-termination of cables by using suitable size of aluminium lugs, making functional of in built starter, scrubing of old surface apply synthetic enamel emulsion paint with spray gun over a coat of primer, complete all as specified and directed.

2

-

-

... More
Material and labour for draining out entire water from open underground static water tanks of capacity 60000 Gallon, cleaning of all accumulated sand, sandy mud, insoluble particles, silt, etc. inside the tank, with the help of coir brush, jute cloth and flushing out/wiping off clean and applying two coats of lime wash on all internal surfaces like wall, ceiling, floor, etc, complete all as specified and as directed

6

-

-

... More
Supply and fixing in repair framed work such as grills, gratings etc with end s of bars shouldered and/or riveted or forged into,framed guard bars, ladders, framed bausters, walk ways , railings, frame work of water tanks and similar works confirming to FE 290 Gde-E-165, complete all as specified and directed.

170

-

-

... More
Demolition of Concrete of any description and in any position not otherwise specifically provided, complete all as specified and as directed.

3

-

-

... More
Material and labour for PCC 1:3:6 type C-2 using 40mm graded mechanically crushed stone aggregates for making good disturbed surfaces of roads / hard standing, etc. and finishing the top surfaces even and smooth without using extra cement, complete all as specified and as directed.

3

-

-

... More
Material and labour in repair suction pipe line 80mm bore GI heavy grade with flange, 4 hole for sewage pump complete with nut bolt and gasket, complete all as specified and as directed.

30

-

-

... More
Material and labour in repair suction pipe line 100mm bore GI heavy grade with flange, 4 hole for sewage pump complete with nut bolt and gasket, complete all as specified and as directed.

30

-

-

... More
Material and labour for Cleaning of raw sewage sumps/ wells of any size and depth in any location at Barnala camp mechanical means only by using sewage collection machine including dewatering and removing the balance sludge using necessary T&P required at site such as pump set for De-watering, tripod, chain pully, rope, steel bucket, phawara etc for completion of Job for cleaning upto bottom of the well and taking out all clay/sludge/mud/stone pieces and other material deposited in the sewage well during course of time and removing deposited material to a distance from 50 mtr the site of well including cleaning and greasing, painting of all submersible pumps & motor inside, complete all as specified and as directed. Note: 1. Work shall be carried out in foul conditions. 2. Sewage/ sludge shall be removed in closed container mounted on vehicle. 3. Contractor has to provide all necessary safety gears & protective equipment to the labours engaged. 4. Work shall be carried out as and when required. 5. Work will be done only when one supervisor is present on site who will be responsible for ensuring safety of the labours engaged.

3

-

-

... More
Supply only poly electolyte chemical for disinfection of raw sewage water, ISI marked, complete all as specified and as directed.

25

-

-

... More
Supply only alum ferric base chemical for disinfection of raw sewage water, ISI marked, complete all as specified and as directed.

50

-

-

... More
Supply only poly aluminium carbon chemical for odour removal of treated sewage water, ISI marked, complete all as specified and as directed.

50

-

-

... More
Supply only sodium Hypochlorite 5.25% (bleach concentrate for treated sewage water, ISI marked, complete all as specified and as directed.

50

-

-

... More
Material and labour for lifting and lowering/and Cleaning of Submercible type sewage pump 3 pahse, capacity 7.5/15 HP, with Chain pully with nuts and bolts and rubber Joint and reassembling, connecting, testing and making serviceable, complete all as specified and as directed.

12

-

-

... More
Supply only calcium based Hypochlorite 65% to 70% calcium based white to off white free flowing and free from lumps in 45 Kg drum packing, complete all as specified and as directed.

1350

-

-

... More
Supply only LT insulation tape size 25mm width Appx 30 Mtr length, complete all as specified and as directed.

300

-

-

... More
Taking down carefully water geyser/solar geyser any capacity, cable sealing end and dismantling of heating element, thermostat etc and refixing after repairs, connecting up and testing for satisfactory heating of water complete all as specified and as directed. Note :- Spare parts shall be measured and paid serparately as supply only.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.