Military Engineer Services Tender
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Costs
EMD
₹ 40,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_668264_1Bid Award Id
ViewTender No
GE/LDH-25/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Removal of excavated surplus spoil to a distance not exc 50 metre and depositing where directed at level not exceeding 1.5 metre above the starting point complete all as specified & directed .
76.89
-
-
Taking down CI/DI/GI water mains including burning out joints and recovering lead size of bore 150mm complete all as specified & directed .
33
-
-
All as per srl item No 04 above but 100 bore.
150
-
-
All as per srl item No 04 above but 80 bore.
33
-
-
Supplying, and laying and testing in trenches, cutting, reducing, jointing/ connecting and testing 150 mm bore ductile iron pipe class 'k-7' with spigot and socketed ends, centrifugally cast suitable joint complete all as specified and directed .
33
-
-
All as per srl item No 07 above but 100 bore ductile iron pipe.
150
-
-
All as per srl item No 07 above but 80 bore ductile iron pipe.
33
-
-
Taking out/dismantling of existing GI tubing 80 mm bore with all fittings complete all as specified & directed .
50
-
-
All as per ser item No 10 above but GI tubing 50 mm bore.
200
-
-
All as per ser item No 10 above but GI tubing 40 mm bore.
200
-
-
All as per ser item No 10 above but GI tubing 25 mm bore.
300
-
-
All as per ser item No 10 above but GI tubing 20 mm bore.
400
-
-
Supply & fixing galvanised iron tubes of size 80mm bore (medium grade) with all fittings and laid in trenches, under floor or road including fittings such as socket, bend, elbow, union etc. complete all as specified & directed .
50
-
-
All as per ser item No 15 above but GI tubing 50 mm bore.
200
-
-
All as per ser item No 15 above but GI tubing 40 mm bore.
200
-
-
All as per ser item No 15 above but GI tubing 25 mm bore.
300
-
-
All as per ser item No 15 above but GI tubing 20 mm bore
Note:- (For ser item No 04 to 19) Necessary Earth work shall be measured and paid separately under appropriate item of this schedule.
400
-
-
M & L for repairs to leakage run lead joint in any position of size 150 mm bore CI pipes by burning out existing joints ,cleaning internal surfaces of socket and providing new joints with using new lead, making joint leak proof, complete all as specified.
Note :- (i) Necessary earth wrok shall be included in quoted rates. (ii) T& P and minor spares shall be provided by the contractor without any extra cost.
10
-
-
All as per ser item No 20 above but Size of CI pipe 100mm bore .
10
-
-
All as per ser item No 20 above but Size of CI pipe 80mm bore.
10
-
-
Repairs to leakage run rubber gasket joint or flanged joint for 150mm bore pipes and fittings including necessary fittings such as bolts, nuts, washers, white lead or mineral oil complete all as specified and directed . Note :- (i) Necessary earth wrok shall be included in quoted rates. (ii) T& P and minor spares shall be provided by the contractor without any extra cost.
10
-
-
All as per item No 23 above but Size of GI/CI/DI pipe 100mm .
15
-
-
All as per item No 23 above but Size of GI/CI/DI pipe 80mm .
15
-
-
Supply & fixing ductile iron fitting upto 150mm bore such as bends (any type, radius and angle), tapers any type (straight, bend, increasing, decreasing or double socket etc), Tee pieces, single branch, 'Y' junction, double branch, cross collar, caps and plugs etc. suitable for spigot and socketed pipes including taking out the defective one form the trenches or ground all as specified and directed .
300
-
-
Taking out old US sluice valves size of 150 mm from valve pit chamber and refixing after replacement of spindle and check nut as per exisiting, incl refacing & regrinding for fixing in its original position complete all as specified and directed.
Note : rate of nut bolts and rubber gasket for fixing shall be included in quoted rates.
10
-
-
All as per ser item No 27 above but sluice vlave size 100 mm bore.
10
-
-
All as per ser item No 27 above but sluice vlave size 80 mm bore.
10
-
-
Supply and fixing in replacement cast iron sluice valve suitable for 150mm bore pipe with flanged ends drilled ISI marked class PN-1.6 conforming to IS- 14846 with stainless steel spindle, CI gate with brass nut, bolt, washer and rubber packing for connecting pieces etc including taking out complete all as specified and directed .
2
-
-
All as per ser item No 30 above but cast iron sluice valve 100 mm bore.
1
-
-
All as per ser item No 30 above but cast iron sluice valve 80 mm bore.
1
-
-
Supply and fixing in replacement cast iron non return valve with GM sheet and flap of size 100 mm bore flanged ISI marked including bolts nuts, washer and rubber gasket etc including removing the existing one complete all as specified and directed .
1
-
-
Supply and fixing in replacement air release valve cast iron with double air valve 80 mm bore etc complete all as specified and directed .
1
-
-
M&L for drilling and tapping cast iron water mains (in any position) for branch connection of the internal dia 20 mm bore complete all as specified and as directed.
1
-
-
Supplying in replacement of synthetic rubber insulated mats 2.0 mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and directed.
5
-
-
Supply & fixing in replacement gun metal gate valve 20 mm bore with iron wheel with necessary fittings for GI pipes with necessary fittings complete, all as specified & directed.
100
-
-
All as per ser item No 37 above but 25 mm bore.
80
-
-
All as per ser item No 37 above but 40 mm bore.
15
-
-
All as per ser item No 37 above but 50 mm bore.
10
-
-
Supply and fixing in replacement of self priming centrifugal type dosing pump automatic sensor based including LCD screen on/off discharge capacity of 10 litre /hour with IP-65 protection antiacid plastic casing, control panel protection weather proof and resisting UV rays, standrad power supply 230V AC 50 HZ single phase with sensor, complete with agitators all as specified and as directed.
3
-
-
S&F in repair of Over load relay 0 to 63 Amps 415 V complete all as specifed and directed.
5
-
-
S&F in repair of contrator as per existing make or model of current rating upto 70 Amp, 415V complete all as specifed and directed..
3
-
-
S&F in repair of Single phase preventor VSP-3 complete all as specifed and directed. .
5
-
-
S & F in repair of Star delta timer ETR complete all as specifed and directed.
5
-
-
S & F in repair of MPCB 0 to 63 Amp 3 Phase 3 pole complete all as specifed and directed.
2
-
-
S & F in repair of Voltmeter 0 to 500 Volt digital type complete all as specifed and directed.
4
-
-
S & F in repair of Ampere meter 0 to 200 amp with CTs square digital type complete all as specifed and directed..
4
-
-
S&F in replacement of phase indicating lamp complete complete all as specifed and directed..
18
-
-
M&L for Dismantling the water mains from the delivery lines, lifting/taking up GI Column pipes 100/80 mm, pumping sets including submersible cable (Appx depth of well is 400 Feet) disconnecting pumping sets of capacity 20 to 35 HP from cable and column pipe for carried out repair maint work and after repair Lowering of submersible pump Sets, submersible cable, column pipes, reonnecting main delivery mains as existing and testing for satisfactory running and continuous flow of water etc complete all as directed at bore wells at various location in dholewal mil camp. Note :-
1. Repair to Motor & Pumping sets shall be measured and paid seperately. Column pipes as required for replacement shall be measured under relevant item of schedule 2. Rate quoted by the contractor shall deemed to be include, transportation to workshop and back at site including minor consumable/repair items like nut bolts , rubber packing 3 mm etc and taking out & lowering of submersible motor is included in quoted rate.
2
-
-
Dismantling and Rewinding of submersible motor of any make & capacity 25/30 HP by using existing size and gauge of PVC insulated single core copper conductor submersible winding wire including all insulated material incl replacement of upper & lower housing bushes , 3 Nos gun metal bushes, stainless steel sleeves, 'O' ring kit and oil seal kit, thrust bearing excel (carbon), thrust bearing plate, sand guard gun metal, water seal and reassembling complete set after carryout necessary repair work & testing complete for smooth functioning to the entire satisfaction of Engr-in-Charge. Note - (i) Rates for New spare parts & components shall be included in quoted rates under this item of schedule.
(ii) Rate quoted by the contractor shall deemed to be included lifting and transportation to workshop and back at site including minor consumable/repair items like nut bolts , rubber packing 3 mm etc and taking out & lowering of submersibnle motor is included in quoted rate.
4
-
-
M&L disconnecting water & electric connections and taking out existing chlorination pumping set, transporting & servicing of the pump and motor at manufacturer's authorised workshop, bringing back the pumping set at original location, reconnecting and testing the same complete all as specified and directed . Note:-Supply and replacement of defective parts required to be replaced shall be included in quotes rates under this item of schedule.
2
-
-
S & F in replacement of FRP container of capacity 100 ltr with PVC fittings for chlorine mixing as pump house as per specified and directed.
5
-
-
S&F calcium hypochlorite having 60% to 70% available chlorine must contain appropriate quantities of dispersants/corroson inhibitor to prevent encrustation/scaling in distribution system Note contractor supplier must submit govt lab test report of calcium hypochlorite alonbgwith each delivery, packed in 45 KG plastic drum complete all as specified & directed .
1125
-
-
Supply and fix n replacement of 1100 volts grade heavy duty PVC insulated flat submerssible cable 16 sqmm, 3 core with copper conductor complete as specified.
150
-
-
Supply and fixing in replacement of MS column pipe heavy grade of size 100 mm bore 3m long of each piece flanged both ends and slot made for submersible cable as in replacement complete all as specified and directed.
8
-
-
Supply and fixing in replacement of MS column pipe heavy grade of size 80 mm bore 3m long of each piece flanged both ends and slot made for submersible cable as in replacement complete all as specified and directed. Note :- (For srl item No.56& 57) Spare as nut bolt, rubber seal shall be include in quoted rates.
8
-
-
M & L to Repairs of leakage any type through rubber gasket joints or flanged joints at vertical fitted pipes with over head reservoirs located at pump houses at dholewal mil camp area size upto 150mm CI or DI including necessary jointing or welding work complete all as specified as directed.
Note:- (i) Necessary T&P and safety equipment and transportation for civil market if any , shall be provided by contractor without any extra cost. Any type of earth work and cement work (PCC) shall be included in quoted rates. (ii) demolistion of base of tank or any other portion shall me made as per original by the contractor without any extra cost. rates of consumable items like nut bolt wahser rubber sheets are included in qauoted rates.
(iii) Any portion of pipe line or fitting spare shall measured separately and paid under relevant item of this scheudle.
6
-
-
Supply and fixing in replacement automatic star-delta starter with MPCP protection in sheet metal enclosures, 415 volts, 3 phase, 50 Hz type,. ML-3 with overload relay range upto 60 Amp suitable for upto 35 HP submersible motor all as specified and directed .
3
-
-
Supply only residual chlorine and ph test kit upto 5 PPM with 500 ml bottle of Todaline reagent solution complete all as specified.
15
-
-
Testing portability of water by chemical analysis as per IS- 10500 such as PH value, dissolved solids, hardness as CaCO3, calcium, magnesium, chlorides, sulphates, nitrate, alkalinity, iron, turbidity NTU, mineral oil, colour hazen units, taste, odour, residual free chlorine, total coliform per 100ml (microbiological test) & E coli per 100ml (microbiological test) as well as bacteriological portability from any Govt. Laboratory or any NABL accrediated Lab complete all as specified & directed.
Note:- (I) The cost of sampling, transporation and testing charges shall be born by the contractor. (ii) testing shall be made on quarterly routine at every pump house or as per directed by Engr-in -Charge
15
-
-
Supply and Fix in replacement of off load Changeover Switch 100 A, 4P 415 V with enclosure complete all as specified and as directed.
4
-
-
Supply and Fix in replacement of ON load Changeover Switch 100 A, 4P 415 V with enclosure complete all as specified and as directed.
2
-
-
M& L in repair of PCC chamber of earth pit size of 300x300x300mm(top of chamber minimum 15 cm above the normal ground level (1:3:6) using 20mm graded stone aggregate and RCC cover (1:2:4) type B-I using 20mm graded crushed stone aggregate of 25mm thick with 2 nos MS handles of 12mm dia including necessary earth work if reqd, replacement of funnel or wire mesh and taking out and refixing of GI pipe and earth strip also included in quted rate.
25
-
-
M & L in replacement of Earthing complete for LT Panels/ Feeder Pillars with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground vertically at a depth not less than 2.25 metres below normal ground level with top edge of the plate at a depth not less than 1.5 metres below normal ground level, connected with and including GI strip 32mm x 6mm and including GI pipe 50mm bore light grade as protection pipe (from top of earth plate up to the test point) by means of GI bolts, nuts, check nuts and washers of GI and thimbles, earth plate surrounded by packed layers of charcoal dust and common salt 15cm thick, all around including top and bottom and watering pipe 20mm bore of GI pipe medium grade with funnel and wire mesh, PCC chamber of size 300x300x300mm(top of chamber minimum 15 cm above the normal ground level (1:3:6) using 20mm graded stone aggregate and RCC cover (1:2:4) type B-I using 20mm graded crushed stone aggregate of 25mm thick with 2 nos MS handles of 12mm dia including necessary excavation/ earth work in any type of soil/rock and as shown in Electrical plate No. 3 of SSR Part-I (2009) testing on completion complete all as specified.
Note : 1. If result is not satisfactory then contractor will do the on other location without any extra cost.
10
-
-
M& L for repair of Motor starter panel by welding & painting including replacement of Over load relay 0 to 63 Amp 415 V, Power Contrator as per existing rating or model, Single phase preventer VSP-03, MPCB for motor protection, Digital multifunctional meter 0-200 Amp- & 415 Volt , Phase indication lamp, complete all as specified.
2
-
-
Supply only gland packing rope style 310/350 for locking leakage in sluice valve size 80/100/150 mm as specified.
50
-
-
Supply and fixing in replacement of Computerised Distribution chart in r/o pump houses with clear glass cover & wooden frame size of 120 cm X 120 cm complete all as specified and directed.
Note :- Rough distribution sketch shall be provided by the Dept.
5
-
-
M& L in replacement of pump house name board box type with in built LED lights of at water supply pump house dholewal, fitted with required height of angle iron frame size of 23 ft X 2.5 ft of arcylic sheet, complete all as specified and directed.
Note:- (i) rough data shall be provided by department (ii) rates for necessary brick work and angle iron frame, led lights shall be included in quoted rates.
4
-
-
M& L for shock treatment chart/ chlorination instruction chart in wooden frame with covered glass in three language ( English, Hindi, Punjabi) size of 50 cm X 70cm with porper fixing arrangement complete all as specified and directed.
Note:- (i) Data for printing shall be provided by department
20
-
-
M& L for repair to valve pit of water supply distribution system including welding/replace of broken hinges of wall pit covers, two coat of synthetic enamel paint (black) after one coat of red oxide, plaster (1:4) 15 mm thick area not exc 1.5 sqm incl white wash three coat complete all as specified and directed.
30
-
-
Supply , fixing, testing and commssioning electonic water level indicator device sensor system with LED indication lights, 10 level showing water level as per predetermined limits and auto cut off on power failure complete all accessories complete all as specified & directed. Note:- Necessary wire and fixing arrangement shall be include in quoted rates.
2
-
-
M & L for plain cement concrete (PCC) 1 : 2 :4 type B2 using 40mm crushed stone aggregate, as in repairs to Valve pits / disturbed hard standing/ road or any other repair as required at site at any situation complete all as specified as directed.
1.2
-
-
Demolition of brickwork or stone/ boulder masonary, built in lime mortar including all quoins, arches, pillers etc. of any description and in any position, removing demolished material from site complete all as specified and directed.
1
-
-
M & L for brick work with sub class 'B' bricks, straight or curved on plan exc 6m mean radius and built in cement mortar 1:4 as in repair/raising /making of valve pit chamber complete all as specified and directed.
1
-
-
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc.
20
-
-
M&L for rendering 15mm thick plaster on fair faces of brick work or concrete surfaces with CM 1:4 finished the surface even and smooth without using extra cement complete all as specified and directed.
20
-
-
M&L preparing new plastered surfaces applying three coats of white wash on walls complete all as specified and directed.
20
-
-
Supply & fixing febricate and fixing MS framed grills,gratings, framed guard bars,ladder, framework of Valve pit cover, water tanks etc, or similar work as ordered and febricated from MS rolled section of any size and shape as directed and fixed at position with all fixing accessories complete.
200
-
-
M & L for MS plate /sheet plain or chequered, 3.00 mm thick cut to pieces as required and fixed to MS frame work by means of Electric arc/gas welding all as directed and specified.
158
-
-
M&L for prepation new painted metal surfaces of any description, over 10cm in width or girth and appling two coat of synthetic enamel paint of approved tint, complete all as specified and as directed.
10
-
-
M&L preparing old steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
160
-
-
Supply & fixing in replacement LED aviation obstruction light fitting 302 LED (RED Colour) IP 55 with all accessories, brackets for fixing arrengement etc. on over head tank complete all as specified & directed.
2
-
-
M&L for Cleaning, painting of overhead tank out and in side,Painting to raising/delivery/wash out/over flow CI/DI pipe line upto 150 mm dia Over Head reservoir (RCC) as per existing colour (Apex) code including preparation of old surface of painting with one coat of synthetic enamel paint from ground level to bottom of the dome of the tank complete removing all scale & dirt from bottom & walls and from mouth of circulation pipes of overhead tank of capacity 50,000 gallons at staging height exceeding 18 metre and not exceeding 21.5 metre and disinfecting chemical the same using disinfecting chemical (chlorine) at dholewal militaray complex complete all as specified & directed.
Note :- (i) The rate quoted shall be deemed to include the cost of neccessary scaffolding,supports, safety device etc.contractor is fully responsible for the safety equipment for the workers. (ii) Appx paint for RCC tank & structure and enamel paint for pipe lines as directed by Engr-in-charge.
5
-
-
Demolition of Concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed and removing rubbish off the premises.
1.2
-
-