Military Engineer Services Tender
... More
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Costs
EMD
₹ 97,440Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_709002_1Tender No
GE(AF)/ADM/T-28 OF 2025-26Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each, complete, all as specified and directed.
18
-
-
... More
Removing excavated spoil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete, all as specified and directed.
12
-
-
... More
M&L for Cement concrete (1:2:4) type B-0 using 12.5mm graded crushed stone aggregate as in bed block of hold fast, coping including necessary form work etc complete all as specified and directed.
5
-
-
... More
M&L for PCC type C-2 (1:3:6), type C-2 using 40 mm graded stone aggregates as in filling & mass concrete complete all as specified and directed.
25
-
-
... More
M&L for PCC type C-2 (1:3:6), using 40 mm graded crushed stone aggregates as in surface channels & drains etc. complete all as specified and directed.
10
-
-
... More
M&L for Plain Cement concrete (1:2:4) type B-1 using 20mm graded crushed stone aggregate as in coping,weathering, slightly rounded or chamfered angles and throating complete all as specified and directed.
3
-
-
... More
M&L for Providing precast cement concrete (1:2:4) type B-0 using 12.5mm graded crushed stone aggregate louvres and jallies, 25mm thick (measured solid), including all mould- ings but excluding frame complete all as specified and directed.
10
-
-
... More
Reinforced cement concrete, type A-1(1:1½:3), (nominal mix) using 20 mm graded crushed stone aggregates as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
1
100
100
... More
M&L for Reinforced cement concrete, type A-1(1:1½:3), (nominal mix) using 20 mm graded crushed stone aggregates as in columns, pillars, piers, posts and struts complete all as specified and directed.
2
100
200
... More
M&L for Reinforced cement concrete (1:2:4) type B-1 using 20mm graded crushed stone aggregate as in manhole covers and the like duly placed on manholes with cement mortar (1:4) complete all as specified and directed.
3
-
-
... More
M&L for Use & waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter with rough finished surfaces of concrete, complete all as specified and directed.
2
100
200
... More
M&L for Use & waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions with rough finished surfaces of concrete, complete all as specified and directed.
5
100
500
... More
M&L for Brick work using bricks as specified in PS clause 5, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar (1:6), complete all as specified and directed.
20
-
-
... More
M&L for Brick work using old size bricks (EXCEPT BRICKS) straight or curved on plan exceeding 6.00 metre mean radius, built in cement mortar (1:6), complete all as specified and directed.
10
-
-
... More
M&L for Brick work half brick thick wall using bricks as specified in PS clause 5.1, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar (1:4), complete all as specified and directed.
50
-
-
... More
M&L for Brick work half brick thick wall using old size bricks (EXCEPT BRICKS), straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar (1:4), complete all as specified and directed.
50
-
-
... More
M&L for Brick work in brick on edge walls (less than 1/2 brick wall) using bricks as specified in PS clause 5.1, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar (1:4), complete all as specified and directed.
50
-
-
... More
M&L for Brick work in brick on edge walls (less than 1/2 brick wall) using old size bricks (EXCEPT BRICKS), straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar (1:4), complete all as specified and directed.
30
-
-
... More
M&L for Mild steel works in hand rails, half round or other stock section or core for wooden handrail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) in-cluding all necessary drilling, bolting or riveting, etc., confirming to Fe-290-Gde E-165, complete all as specified and directed.
3100
-
-
... More
M&L for Framed mild steel work (ornamental and intricate design) as in doors or gates of angle or other section with gusset plates, rails, braces etc. complete drilled for fixing of steel sheeting or other covering, doors etc to be prepared for hanging or sliding with and including either hooks and hinges for steel hanging door fittings ( exclusive of steel sheeting or other covering, running rails and guides ) and hanging also fastening confirming to Fe-290-Gde E-165 complete all as specified and directed
900
100
90000
... More
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
700
-
-
... More
Fixing only chain link fencing including line wire mesh, any mesh, size and type to any types of standards rails, straining bolts, mild steel round bars etc. including provision of binding wire complete, all as specified and directed.
1100
-
-
... More
Supply only chain link mild steel galvanised hot dipped fencing (mesh size not more than 75mm x 75mm of 10 gauge wire and weight exc. 3.00 kg/Sq.m) complete all as specified and directed.
NOTE:- The weight of chain link fencing shall be ascertained by BOO as ordered by GE and payment shall be made acoordingly.
4400
-
-
... More
Supply only Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5 cm but not exceeding 10 cm long, dia of neck 5 to 10 mm, complete all as specified and directed.
100
-
-
... More
Supply only Mild steel round bars 10mm dia and over, cut to length, bent to shape required, for chain link fencing complete, all as specified and directed.
340
-
-
... More
M&L for Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed, IN REPAIRS, (each line wire to be measured) complete all as specified and directed.
10
-
-
... More
Restraining and resecuring including making good staples etc. only steel barbed wire to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) complete all as specified and directed.
5
-
-
... More
M&L for Concertina coil with punched tape, made to round shape of 600 mm dia with high tensile galvanised wire having diametre not less than 2.5 mm and blade size 15 mm x 12 mm x 0.5 mm, spacing of blade not more than 26 mm, fixed in position over walls etc. IN REPAIRS, complete all as specified and directed. NOTE : For measurement purpose lenth of wire shall be measured straight i.e. perallel to GL after making round shape
2
-
-
... More
M&L for 100 mm thick, cement concrete type D-2, 1:4:8 using 40 mm graded crushed stone aggregate, finished even & rough, as in sub floors, complete all as specified and directed.
1070
-
-
... More
M&L for 100 mm thick, cement concrete type B-2, 1:2:4 using 40 mm graded crushed stone aggregate, finished rough, as in floors or similar locations, complete all as specified and directed.
50
-
-
... More
Extra for forming fair finished drain or channel 30-45 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified and directed.
70
-
-
... More
M&L for Factory made PCC chequered tiles, ISI (IS:13801) marked, with grey cement & no pigment, 22-25 mm thick, of size 300 mm x 300 mm, in floors, over & including 15 mm thick cement mortar (1:4) screed, set and jointed with grey cement slurry complete all as specified and directed.
70
-
-
... More
M&L for Factory made, rubber molded kerb stone and drainage channels of M-25 grade cement concrete, laid dry in position to the rquired line level and curvature, jointed with cement mortar (1:3) including making joints with or without grooves (thickness of joints except at sharp curve shal not be more than 5 mm) including making drainage opening whereever required, complete all as specified and directed.
3
-
-
... More
M&L for 60mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of shape approved by GE, made by table vibratory method using PU mould, laid in required pattern over and including 25mm thick compacted bed of coarse sand, compacting through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed.
250
-
-
... More
M&L for 80mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of shape approved by GE, made by table vibratory method using PU mould, laid in required pattern over and including 25mm thick compacted bed of coarse sand, compacting through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed.
350
-
-
... More
Fixing only cement concrete paver block as in footpath, parks, lawns, drive ways or light traffic parking etc obtained from dismantled tiles or where floor is sunk, including 25mm thick compacted bed of coarse sand, compacting complete all as specified and directed.
250
-
-
... More
M&L for Endura vitrified paving coloured tiles 9 to 10 mm thick (square/ rectangular) area of each tile exc. 0.11 Sq.m but not exc. 0.18 Sq.m, laid in floors etc, set and jointed in neat cement slurry and pointed in grout of matching shade, laid over and including 15 mm thick bedding layer in cement mortar (1:4) complete all as specified and directed.
150
10
1500
... More
M&L for Rendering 15 mm thick on fair faces of brick work or concrete surfaces, finished even and fair on walls in cement mortar (1:4) complete all as specified and directed.
600
10
6000
... More
M&L for Two coats of cement base paint on new plastered wall surfaces, including preparation of surfaces, complete all as specified and directed.
200
10
2000
... More
M&L for Two coats of synthetic enamel paint over & including a coat of red oxide primer over new steel & iron surfaces of any description, not otherwise described, over 10 cm in width or girth, including preparation of surfaces complete all as specified and directed.
175
10
1750
... More
M&L for Reinforced concrete pipe class NP-2 300mm dia , ISI marked, laid in trenches including jointing & testing complete with collars complete all as specified and directed
10
-
-
... More
M&L for Cement concrete (1:3:6) type C-2 using 40mm graded crushed stone aggregate as in bed to 300mm drain pipes of any description including packing under and haunching against the sides of pipe complete all as specified and directed
10
-
-
... More
M&L for Cleaning of open drain laid at any depth (either manually or mechanically) by removing all type of sand / boulder / sludge/ silt and any other foreign material and the same outside MoD land in etc complete all as specified and directed.
NOTE:- The average cross section of drain upto top of filling up silt / sludge etc shall be measured for payment.
5
10
50
... More
Taking down cement or cement lime plaster, any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed.
300
10
3000
... More
Demolition brickwork or stone/ boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
42
10
420
... More
Demolition of cement concrete (unreinforced) in ground floors and pavings not excceding 15cm thickness (above or below ground level) complete all as specified and directed.
161
10
1610
... More
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified..
6
10
60
... More
Dismantling wrought iron or mild steel work of any description, complete all as specified and directed.
5
10
50
... More
Dismantling fencing wire mesh, any type complete complete all as specified and directed.
1100
10
11000
... More
Demolition and breaking up 300mm bore drain pipes (salt glazed stoneware, AC or reinforced concrete) set in cement mortar complete all as specified and directed.
10
-
-
... More
Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground, embedded with concrete etc. complete all as specified and directed.
180
10
1800
... More
PROVN OF DG SET AND ALLIED WORKS FOR AC PLANT IN BLDG NO 6 OF WSA- II AT AF STN ADAMPUR
-
-
-
... More
M&L for Clean dry sand ( locally available) as cushioning for under ground cable 230 mm thick (one layer of 80 mm thickness before laying the cable and other layer of 150 mm thickness after laying the cable) complete all as specified and directed.
NOTE:- Punned down thickness (over all 180 mm) shall be considered for measurement and payment.
6
-
-
... More
Brick protection with pulverized fuel ash lime bricks laid flat across the route of underground cable all as specified.
500
-
-
... More
Supply, installation, testing and commissioning of acoustic proof diesel engine driven generating set fully wired 415 volts + 5% AC, 3 phase 4 wire 50 Hz having capacity 82.5 KVA/66 KW continuous rating at power factor 0.8 (lagging) as per IS 4722 and connections as per IE rules complete with integrated AMF control panel of suitable capacity with microprocessor based relay and safety accessories as per the latest engineering practices . DG set shall be mounted on common base plate with anti vibration pads and placed on PCC foundation of required size as recommended by OEM. The Gen Set shall conform to CPCB-IV norms or latest norms for noise and emission limits and necessary certificate from NAL or equivalant authority to this effect shall be submitted and all as specified and directed consisting of the following :-
1
-
-
... More
[a] DIESEL ENGINE. The diesel engine shall be 4 stroke, water cooled, turbo charged developing minimum at 1500 RPM under NTP conditions of BS: 5514. The engine shall be provided with electrical starting arrangement & shall be suitable to produce an electrical output of 82.5 KVA/66 KW at 0.8 power factor. The engine shall complete with :- Starter motor and charging alternator. Battery as recommended by OEM Dry type air cleaner Fuel pump with injectors A1 class governing Flywheel with flywheel housing Residential silencer First fill of lube oil suitable for 12 Hours continous running at full load Engine protections: Low lube oil pressure & High Water temperature.
-
-
-
... More
[b] ALTERNATOR. The alternator shall be self excited self regulated brush less and self ventilating type designed for an output of 82.5 KVA/66 KW, 50 Hz, 415Volts 4 wire continous rating at 0.8 PF, with class 'F' or better insulation, screne protected, drip proof in IP- 21 enclosure and confirming to IS -4722 BS EN 60034-1 and directly coupled with the engine incl control panel with accessories complete with electric supply terminal box with gland plate, earth terminal etc all as specified.
-
-
-
... More
[c] AMF Panel. AMF panel totally enclosed cubical type dust and vermin proof, with sloped canopy, standard industrial pattern, factory fabricated out of 2.0 mm thick CRCA steel sheet painted with one coat of red oxide primer and two coats of anticorrosive synthetic enamel powder coated of approved colour, complete with all mounting structures, insulators, bolts, nuts, washers etc, with necessary control wiring/internal connections with proper size of copper conductor cables / strips, suitable for 3 phase, 4 wire, 50Hz, 415 volts AC system, comprising of microprocessor based AMF relay unit with sensing on mains and DG with necessary safety / protection, MCCB 415 Volt 50 Hz 125 Amps, 36 KA rating adjustable microprocessor based 4 pole (as incomming)-01 Nos and 2 Nos 4 pole power contactor of 125 Amps for Mains and DG supply, frequency meter, 3 Phase electronic type AC digital type KWH meter with suitable CTs, electronic earth fault protection relay.
-
-
-
... More
AC voltmeter 0-500 V with selector switch, Ammeter 0-630 Amps with selector switch, push buttons for start / stop / reset, LED type indicating lamps as required, SMPS based battery charger with automatic float & boost changeover facility, control circuit/MCBs, reverse power relay, alarm for high water/ lubricating oil temperature and low lubrication oil pressure, any other control devices/measuring instruments as recommended/required as per latest engineering practices complete with cable glands with gland plate for cable entry, control cabling with copper conductor multi-core cables of required cross sectional area from DG set to AMF control panel all prewired and suitable for 82.5 KVA DG set all as specified
-
-
-
... More
[d] SOUNDPROOF CANOPY. Soundproof canopy shall be made using 2.5mm thick CRCA sheet for base and Doors & Roof shall be fabricated form MS CRCA of adequate thickness with modular, bolted construction and will have access from all sides with airtight EPDM foam gasket and insulation with fire retardant PU form, MS/Zinc die cast hinges and powder coated with 9 tank pre-treatment process and the finish shall be suitable for outdoor use. The maximum noise level permitted during full load will be 75 dB (a), measured at 1 meter distance from the edge of canopy. The product shall be certified by COCB as per latest norms. Air inlet and outlet louvers, with special sound reduction dampers for proper air ventilation shall be provided. The canopy will have provision of emergency push button which shall be housed in a protective enclosure with a glass front.
-
-
-
... More
Note:- The cost of PCC platform as recommended by the OEM and the expenses for cost of testing of DG Sets shall deemed to be inclusive of quoted rate.. Make: Kirloskar Green/ Jackson / Powerica / Greaves Cotton or any other make as per Annexure.
-
-
-
... More
Supplying, laying, jointing and testing XLPE insulated heavy duty multi stranded armoured and PVC sheathed LT cable 1100 volts grade with aluminium conductor, cross sectional area 120 Sq.mm, 3.5 core multistranded including cable connecting lugs, glands, jointing materials etc. laid in trenches/ ducts/ along poles/ through pipes complete all as specified and directed.
154
-
-
... More
NOTE:- Excavation and earth work, brick protection and sand cushning will be measured & paid separatly under respective item of BoQ)
-
-
-
... More
Supply, installation, commissioning and testing Polycarbonate ASTA CPRI approved OEM made main LT Panel. The panel shall be made of modular POLYCARBONATE THERMOPLASTIC ENCLOSURES including MCCBs and indicator lamps which shall be UV resistance in accordance with IEC 61439-1, clause 10.2.4: The panel shall be anti-acid & anti corrosive. Degree of protection against mechanical load shall be IK08 (5 Joule) in accordance with IEC 62262. Make-Hensel/Rittal/Emitter/Schneider INCOMING:- 160 Amp, 4 pole MCCB, 25 KA Adj.Thermal & Magnetic Released - 01 No Digital Volt meter 0-500V with inbuilt selector switch - 01 No Digital Amp meter 0-200A with inbuilt selector switch & CT Coils- 01 No
Set of LED type indicating lamps - 01 No Copper Bus Bar 200Amp TPN+E
OUTGOINGS:
125 Amp, MCCB TPN 16KA 415 V Fixed.Thermal & Fixed Magnetic Released - 01 Nos 63 Amp, MCB TPN 10KA 415V C-CURVE - 01 Nos
1
-
-
... More
M&L for Earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI strip 32x6 mm (upto the cross arms) by means of GI bolts/nuts/washers, protected by 40 mm bore GI medium grade pipe. Earth plate shall be surrounded by alternate layer of charcoal or coke and common salt 15 cm thick all around bottom and top. 20 mm bore GI light grade pipe for watering and including funnel, wire mesh, factory made PCC earthing pit chamber & cover including necessary excavation & earth work, all as specified & shown in electrical plate No. 5 of MES Schedule Part – I, complete.
NOTE:- (i) Factory made PCC pit chamber shall be provided at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) The unit rate includes earthing lead & protection pipe upto 7.5 metre from top of earth plate.
4
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%