Puducherry Adidravidar Development Corporation Limited Tender
View complete overview of Puducherry Puducherry Adidravidar Development Corporation Limited Tender
Puducherry Adidravidar Development Corporation Limited Tender
Eprocure
Opening Date11 Jan 2019
Closing Date23 Jan 2019
Tender Amount₹ 29,74,325
Costs
EMD
₹ 59,487Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2019_PADCO_4300_1Bid Award Id
ViewTender No
2245/PADCO/EW/2018-19/4Tender Authority
Puducherry Adidravidar Development Corporation Limited ViewPurchaser Address
-Website
http://pudutenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Code no:5.1.2 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering,shuttering,finishing and reinforcement -All work upto plinth level : 1:1.5:3 (1 cement : 1 .5 coarse sand : 3 graded stone aggregate 20mm nominal size)
3
-
-
... More
Code no:5.3.1 Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15 degree landings, balconies, shelves, chajjas, lintels, bands, p ain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centering, shuttering,finishing and reinforcement with 1:1.5:3 (1 cement :1.5 coarse sand : 3 graded stone aggregate 20mm nominal size).
7.5
-
-
... More
Code no:5.9.1 Centring and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete.- Using steel sheet with M.S.frames
22
-
-
... More
Code no:5.9.3 Centring and shuttering including strutting, propping etc. and removal of form for : suspended floors, roofs, landings, balconies and access platform - Using steel sheet with M.S.frames
57
-
-
... More
Code no:5.9.5 Centering and shuttering including strutting, propping etc. and removal of form for: lintels, beams, plinth beams, girders, bressumers and cantilevers.- Using steel sheet with M.S.frames
14
-
-
... More
Code no:5.18.1 Providing precast cement concrete jali 1:2:4 (1cement : 2 coarse sand : 4 graded stone aggregate 6mm nominal size) reinforced with 1.6 mm dia mild steel wire including centring and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3 (1 cement : 3 fine sand) etc. complete excluding plastering of the jams, sills and soffits.- 50 mm thick
3
-
-
... More
Code no:5.22.6 Reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete - Thermo - Mechanically treated bars (TISCON / VIZAG / IISCO /SAIL / JSW) including placing the M30 grade Athees make cover block @ 60cm centre to centre
1425
-
-
... More
Code no:6.1.1 Brick work with FPS bricks of class designation 35 in foundation and plinth in cement mortar 1:4 (1 cement : 4 coarse sand)
30
-
-
... More
Code no:6.4.2 Brick work with FPS bricks of class designation 35 in superstructure above plinth level upto floor V level in all shapes and sizes in cement mortar 1:6 (1 cement : 6 coarse sand)
15
-
-
... More
Code no:6.12.2 Half brick masonry with FPS bricks of class designation 35 in foundation and plinth in cement mortar 1:4 (1 cement: 4 coarse sand)
27
-
-
... More
Code no:6.15 Extra for providing and placing in position 2 nos. 6mm dia MS bars at every third course of half brick masonry (with FPS bricks).
27
-
-
... More
Code no:9.134.1 Providing and fixing of 65mm Godrej Navtal lock of 6 levers etc complete
22
-
-
... More
Code no:10.5.2 Providing and fixing 1mm thick M.S. sheet door with frame of 40X40X6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30X6mm for diagonal braces and central cross piece.
14
-
-
... More
Code no:10.27 Supplying and fixing of steel grill work of m.s. angles,flats,squares and pipes including cost of welding charges, fixing in position in masonry walls with cement concrete 1:2:4 (1 cement : 2 course sand : 4 graded stone aggregate 12.5mm nnominal size) including one coat of priming coat etc. complete.
216
-
-
... More
Code no:11.36A Providing and fixing 1st quallity ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacture of approved make (Jhonson / Asian / Somany / Nitco) in all colours, shades of size 200 x 300 mm as approved in skirting, risers of steps and dados over 12mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm. Including pointing in white cement mixed with pigment of matching shade complete. - size 200x300mm
105
-
-
... More
Code no:11.37 Providing and laying ceramic glazed floor tiles 300X300mm (thickness to be specified by the manufacture) of 1st quality conforming to IS : 15622 of approved make (Bell / Johnson / Regency / Somany / Naveen / Asian ) in colours such as white, ivory, grey, fume red, brown laid on 20mm thick cement mortar 1:4(1 cement : 4 Coarse sand) including pointing the joints with white cement and matching pigment etc., complete
22
-
-
... More
Code no:12.15.1 Painting top of roofs with bitumen of approved quality at 17kg per 10sqm impregnated with a coat of coarse sand at 60 cudm per 10 sqm including cleaning the slab surface with brushes and finally witha piece of cloth lightly soaked in kerosene oil complete: With residual type petroleum bitumen of penetration 80/100.
45
-
-
... More
Code no:12.20 Providing and laying pressed clay tiles (as per approved pattern 20mm nominal thickness and of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 coarse sand) mixed with 2% intergral water proofing compound laid over a bed of 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat complete.
45
-
-
... More
Code no:12.41.2 Providing and fixing on wall face unplasticised rigid PVC rain water pipes conforming to IS : 13592 type A including jointing with seal ring conforming to IS :5382 leaving 10mm gap for thermal expansion, (i) single socketed pipes. 110mm diameter
40
-
-
... More
Code no:12.42.3.2 Providing and fixing on wall face unplasticised- PVC moulded fittings / accessories for unplasticised rigid PVC rain water pipes conforming to IS : 13592 type A including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion. Single Tee with door 110X110X110mm.
20
-
-
... More
Code no:13.1.1 12mm cement plaster of mix :Cement mortar 1:4 (1 cement : 4 fine sand)
208
-
-
... More
Code no:13.16.1 6mm cement plaster of mix 1:3 (1 cement : 3 fine sand).
40
-
-
... More
Code no:14.66.1 Finishing walls with Acrylic Smooth exterior paint of required shade - Old work (Two or more coats applied @ 1.67 lts/10 sqm.) on existing cement paint surface
935
-
-
... More
Code no:13.46.1 Finishing walls with Acrylic Smooth exterior paint of required shade - New work (Two or more coat applied @ 1.67 ltr / 10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg / 10 sqm)
250
-
-
... More
Code no:13.61.1 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade - Two or more coats on new work.
55
-
-
... More
Code no:16.95 Supplying fixing and commisioning of Suguna/ Texmo /Sharp 1 HP monoblock pumpset slow speed single phase motor. The rate include the cost of pumpset , pumpset fixing in position and test run etc. complete .
1
-
-
... More
Code no:17.7.2 Providing and fixing wash basin with CI brackets, 15mm CP brass pillar taps 32 mm CP brass waste of standard pattern including painting of fittings and
brackets, cutting and making good the walls wherever required White vitreous china wash basin size 630x450mm with a single 15mm CP brass pillar taps.
3
-
-
... More
Code no:17.13.2 Providing and fixing white vitreous china water closet squatting pan (Indian type) Orissa pattern WC pan of size 580 x 440 mm.
6
-
-
... More
Code no:18.9.11 Providing and fixing ASTM pipes including all ASTM plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fitting with one step ASTM solvent cement and testing of joints complete (Internal work exposed on wall) - 20mm nominal outer dia pipes
180
-
-
... More
Code no:18.9.12 Providing and fixing ASTM pipes including all ASTM plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fitting with one step ASTM solvent cement and testing of joints complete (Internal work exposed on wall) - 25mm nominal outer dia pipes
85
-
-
... More
Code no:18.9.13 Providing and fixing ASTM pipes including all ASTM plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fitting with one step ASTM solvent cement and testing of joints complete (Internal work exposed on wall) - 32mm nominal outer
dia pipes
50
-
-
... More
Code no:18.15.2 Providing and fixing brass bib cock of approved quality - 20 mm nominal bore.
20
-
-
... More
Code no:18.46.2 Providing and fixing G.I. union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (new work) 20 mm nominal bore.
2
-
-
... More
Code no:18.46.3 Providing and fixing G.I. union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (new work) 25 mm nominal bore.
2
-
-
... More
Code no:18.46.4 Providing and fixing G.I. union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (new work) 32 mm nominal bore.
2
-
-
... More
Code no:18.48 Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI: 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet outlet and overflow pipes but without fittings and the base support for tank
3000
-
-
... More
Code no:19.30.1.1 Constructing brick masonry chamber for underground CI inspection chamber and bends with 75 class designation bricks in cement mortar 1:4 (1 cement: 4 coarse sand) CI cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) R.C.C top slab with 1:2:4 mix (1 cement :2 coarse sand:4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement: 5 fine sand: 10 graded stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design Inside dimensions 450 x 610 mm and 45 cm deep for single pipe line with F.P.S bricks.
4
-
-
... More
Code no:30.7 Supply of Quary rubbish including stacking to department gauge for premeasurement and spreading required thickness as directed by
the Engineer-in-charge
656
-
-
... More
Code no:31.9.1 Providing and fixing brass gate valve with C.I. wheel of approved quality (screwed end) - 15mm nominal bore.
6
-
-
... More
Code no:31.9.3 Providing and fixing brass gate valve with C.I. wheel of approved quality (screwed end) - 25mm nominal bore.
2
-
-
... More
Code no:31.162.1A Providing, laying and jointing UPVC pipes(Finolex/Jain) (0.4 Mpa) conforming to IS specification 4985 and ISI marked including transportation to the site, lowering to the trenches, laying to proper grade and alignment, testing of joints with required testing equipment, including cost of solvent cement,UPVC specials such as
bends,tees, threaded pieces, couplers, reducer, endcaps etc.,complete all as per IS and CPWD specification. - 63mm dia.
60
-
-
... More
Code no:31.162.1D Providing, laying and jointing UPVC pipes(Finolex/Jain) (0.4 Mpa) conforming to IS specification 4985 and ISI marked including transportation to the site, lowering to the trenches, laying to proper grade and alignment, testing of joints with required testing equipment, including cost of solvent cement, excluding UPVC specials such as bends, tees, threaded pieces, couplers, reducer, endcaps etc.,complete all as per IS and CPWD
specification. - 110mm dia.
70
-
-
... More
Code no:32.39.2 Making soak pit 2.5m diameter 3.0 metre deep with 45x45cm dry brick honey comb shaft with bricks of class designation 35 and S.W drain pipe 100mm diameter, 1.8m long complete as per standard design - with brick of class designation 35.
1
-
-
... More
Code no:1.1.2.1 Supplying and laying of following size of PVC conduit in roof slab alongwith the accessories .Make:Avonplast/Vijaya:- 20mm dia
90
-
-
... More
Code no:1.1.2.2 Supplying and laying of following size of PVC conduit in roof slab alongwith the accessories .Make:Avonplast/Vijaya:- 25mm dia
100
-
-
... More
Code no:1.1.3.1.4 Supplying and fixing of following size of PVC junction box in required position along the line of PVC conduit as required. Make:Avonplast/Vijaya:- 20mm Junction Box four way
15
-
-
... More
Code no:1.1.3.2.1 Supplying and fixing of following size of PVC junction box in required position along the line of PVC conduit as required. Make:Avonplast/Vijaya:- 25mm Junction Box one way
15
-
-
... More
Code no:1.3.2 Supplying and fixing of the following sizes of Teak wooden board on recess including cutting the wall and finishing the surface good the same as required - 150mm X 100mm X 50mm. Deep
4
-
-
... More
Code no:1.3.5 Supplying and fixing of the following sizes of Teak wooden board on recess including cutting the wall and finishing the surface good the same as required - 200mm X 150mm X 50mm. Deep
10
-
-
... More
Code no:1.3.6 Supplying and fixing of the following sizes of Teak wooden board on recess including cutting the wall and finishing the surface good the same as required - 250mm X 100mm X 50mm. Deep
3
-
-
... More
Code no:1.3.8 Supplying and fixing of the following sizes of Teak wooden board on recess including cutting the wall and finishing the surface good the same as required - 250mm X 200mm X 50mm. Deep
25
-
-
... More
Code no:1.3.11 Supplying and fixing of the following sizes of Teak wooden board on recess including cutting the wall and finishing the surface good the same as required - 300mm X 200mm X 50mm. Deep
25
-
-
... More
Code no:1.3.17 Supplying and fixing of the following sizes of Teak wooden board on recess including cutting the wall and finishing the surface good the same as required - 375mm X 300mm X 50mm. Deep
10
-
-
... More
Code no:1.5.1 Supplying and drawing of 1.5 sqmm. FR PVC insulated, copper conductor, single core cable in the existing surface/recessed, PVC/steel conduit/PVC casing and capping as required. Make: Finolex/Polycab:-
3630
-
-
... More
Code no:1.5.2 Supplying and drawing of 2.5 sqmm. FR PVC insulated, copper conductor, single core cable in the existing surface/recessed, PVC/steel conduit/PVC casing and capping as required. Make: Finolex/Polycab:-
3125
-
-
... More
Code no:1.5.3 Supplying and drawing of 4.0 sqmm. FR PVC insulated, copper conductor, single core cable in the existing surface/recessed, PVC/steel conduit/PVC casing and capping as required.Make: Finolex/Polycab:-
900
-
-
... More
Code no:1.5.4 Supplying and drawing of 6.0 sqmm. FR PVC insulated, copper conductor, single core cable in the existing surface/recessed, PVC/steel conduit/PVC casing and capping as required.Make: Finolex/Polycab:-
300
-
-
... More
Code no:1.6.2 Providing and fixing of following size phenolic coated sheet on existing wooden board - 150mm X 100mm X 3mm Thick
4
-
-
... More
Code no:1.6.5 Providing and fixing of following size phenolic coated sheet on existing wooden board: - 200mm X 150mm X 3mm Thick
10
-
-
... More
Code no:1.6.6 Providing and fixing of following size phenolic coated sheet on existing wooden board: - 250mm X 100mm X 3mm Thick
3
-
-
... More
Code no:1.6.8 Providing and fixing of following size phenolic coated sheet on existing wooden board: - 250mm X 200mm X 3mm Thick
25
-
-
... More
Code no:1.6.11 Providing and fixing of following size phenolic coated sheet on existing wooden board: - 300mm X 200mm X 3mm Thick
25
-
-
... More
Code no:1.6.17 Providing and fixing of following size phenolic coated sheet on existing wooden board: - 375mm X 300mm X 3mm Thick
10
-
-
... More
Code no:1.7.1.1 Supplying and fixing S.P 1 way 5/6amps piano/flush type switch on the existing switch box/cover including connections etc. as required. Make:Kundan/Anchor/Vinay :-
238
-
-
... More
Code no:1.7.1.3 Supplying and fixing 3 pin 5/6amps piano/flush type socket outlet on the existing switch box/cover including connections etc. as required. Make:Kundan/Anchor/Vinay:-
50
-
-
... More
Code no:1.7.1.4 Supplying and fixing S.P 1 way 15/16amps piano/flush type switch on the existing switch box/cover including connections etc. as required. Make:Kundan/Anchor/Vinay:-
25
-
-
... More
Code no:1.7.1.6 Supplying and fixing 3 pin 15/16amps piano/flush type socket outlet on the existing switch box/cover including connections etc. as required. Make:Kundan/Anchor/Vinay:-
25
-
-
... More
Code no:1.7.1.8 Supplying and fixing 5/6amps indicator on the existing switch box/cover including connections etc. as required. Make:Kundan/Anchor/Vinay:-
20
-
-
... More
Code no:1.7.1.9 Supplying and fixing 10 amps Kit Kat Fuse on the existing switch box/cover including connections etc. as required. Make:Kundan/Anchor/Vinay:-
25
-
-
... More
Code no:1.7.1.15 Supplying and fixing Step type socket Fan Regulator on the existing switch box/cover including connections etc. as required. Make:Kundan/Anchor/Vinay:-
50
-
-
... More
Code no:1.7.2.1 Supplying and fixing 3 plate, 5 amp. ceiling rose on the existing junction box/wooden block including connections etc. as required. Make: Kundan/Anchor/Vinay:-
245
-
-
... More
Code no:1.7.2.2 Supplying and fixing jumbo type Batten/Angle Holder including connections etc. as required .Make: Kundan/Anchor/Vinay:-
62
-
-
... More
Code no:1.8.1.2 Installation, testing and commissioning of prewired, all kind of recess mount light fittings, complete with all accessories etc. on false ceiling, including connections with 16/0.20 mm twin core FR PVC sheathed flat flexible, copper cable etc. as required.
4
-
-
... More
Code no:1.8.1.5 Installation, testing and commissioning of prewired, all kind of surface mount light fittings, complete with all accessories etc. directly on high ceiling/wall, including connections with 16/0.20 mm twin core FR PVC sheathed flat flexible, copper cable etc. as required.
18
-
-
... More
Code no:1.8.2.1 Installation testing and commissioning of ceiling fan/wall mounting fan and wiring the down rod of standard length
.(upto 30cm) with 14/.86mm Plastic insulated twisted Copper wire including earthing as required:
36
-
-
... More
Code no:1.8.2.3 Carriage of ceiling fan and all kinds of light fittings/exhaust fan from store to site as required:-
4
-
-
... More
Code no:1.8.2.5 Installation of exhaust fan upto 450mm sweep in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connections, testing, commission as required.
6
-
-
... More
Code no:2.2.4.2 Supplying and fixing 40 amps rating double pole, (Single pole and neutral) 240 volts, residual current circuit breaker (RCCB) having a sensivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc as required. Make:Siemens/ABB/L&T Hager
1
-
-
... More
Code no:3.1 Earthing with G.I.medium pipe 3.0 mt long and 40mm dia including accessories 250 x 50 x 6 mm G.I clamp with 12mm bolt, nut and washer for connecting earth wire, RCC ring
enclosure and cover plate complete as required:-
8
-
-
... More
Code no:3.3 Extra for salt and charcoal for pipe earth electrode as required:-
8
-
-
... More
Code no:11.2.1 Laying of one number PVC insualted and PVC sheathed/XLPE power cable of 1.1KV grade of exceeding 25sq.mm but not exceeding 120sq.mm direct in ground including excavation sand, cushioning, protective covering and refilling the trench etc as required in Mud Road
8
-
-
... More
Code no:12.2.11 Fixing testing and commissioning of Sodium vapour/Mercury vapour/Metal halide street light fittings on existing poles as required:-
8
-
-
... More
Code no:12.2.12 Supply and fixing of wall mount bracket of 50mm dia GI pipe suitable for SVL / MH fittings with clamp, bolts and nuts as required.
8
-
-
... More
Code no:12.2.13 Supply and fixing of bracket of 25mm dia GI pipe for 40watt STL single / double fitting tube street light with required bolt and nuts complete.
5
-
-
... More
Code no:1808 Supply and fixing 8 SWG copper wire (4.0 mm dia.)
8
-
-
... More
Code no:3051 Supply and fitting 1 x 40W box type single tube light fitting with copper
choke & starter without tube. Make: Philips/Bajaj
50
-
-
... More
Code no:3052 Supply and fitting 2x 40W box type twin tube light fitting with copper choke & starter without tube. Make: Philips/Bajaj
22
-
-
... More
Code no:3053 Supply and fitting 1 x 36w/40w Single tube Street light fittings with sheet aluminium housing and UV stabilized acrylic cover. Make: Philips/Bajaj
10
-
-
... More
Code no:3068 Supply and fitting 250w MH Street light aesthetically designed die cast aluminium with POT optics and toughened flat glass cover (IP 65) Make:Philips
5
-
-
... More
Code no:3081 Supply and fitting Bulk head fitting aluminium alloy body heat resistant prismatic glass cover with specially designed gasket (GLS 100W type) Make: Philips/Bajaj
10
-
-
... More
Code no:3098 Supply and fitting 250W Metal Halide lamp Make: Philips
5
-
-
... More
Code no:3108 Supply and fixing 500W Halogen fitting including bulb Make: Philips
2
-
-
... More
Code no:3112 Supply and fixing 40W tube light. Make: Philips
96
-
-
... More
Code no:3115 Supply and fixing 15W / 20W CFL lamp for pendent holder . Make: Philips
14
-
-
... More
Code no:3117 Supply and fixing 36W CFL lamp for pendent holder Make: Philips
10
-
-
... More
Code no:3127 Supply and fixing1200mm sweep double ball bearing ceiling fan Make:Almonard/Usha
50
-
-
... More
Code no:3129 Supply and fixing 300mm 1400 rpm heavy duty exhaust fan Make:Almonard/Orient/Usha
6
-
-
... More
Code no:3147 Supply and fixing 32A cutout fuse unit Make: Kundan
3
-
-
... More
Code no:3213 Supply and fixing 4 x 50sqmm armoured aluminium U.G cable - 1.1 KV grade. Make:Finolex/Polycab
40
-
-
... More
Code no:3269 Supply and fixing 50mm dia. green spring hose
30
-
-
... More
Code no:1334A Supply and fixing 50 mm dia. GI pipe medium class
16
-
-
... More
Code no:NPSR Fabrication, supply, erection testing and commissioning of one no of timer and metering panel board for the power supply of over all size 1100mm X650mmX250mm made out of 16SWG thick cold rolled MS sheet. The front side compartment have energy meter with viewing glass with 10mm hylem sheet. The back side compartments with 40-63A rating TPN MCB, C Series, 10KVA breking capacity (Make-Siemens/ABB), 1 no of timer switch (Daily) analog with battery backup to 200hrs. (Make- L&T-Hagger/Legrand-Lexic), 1 no 60A power contactor (Make-C&S) 1 no of toggle switch (Make-C&S) 3 nos of signal lamp (Blue red & Yellow) (Make- Siemens/C&S/L&T/Teknic) The switch units are to be fixed with in the alloted size in the 10mm hylem sheet. The bottom sheet of the shell should be of 16SWG thick cold rolled MS sheet with brass gland for cable entry. The panel has to be mounted on the floor with in the height of 375mm. Interior connection between the switch fuse units are to be done with 10Sqmm ISI marked FR PVC insulated single core copper conductor cable (Make -Finolex /Polycab0 The switch units are to be fixed with in the alloted size in the 10mm hylem sheet. The bottom sheet of the shell should be of 16SWG thick cold rolled MS sheet with brass gland for cable entry. The panel has to be mounted on the floor with in the height of 375mm. Interior connection between the switch fuse units are to be done with 10Sqmm ISI marked FR PVC insulated single core copper conductor cable (Make -Finolex /Polycab0 The door should be of flush type inter locking in one position. The panel provided with removable type gland plated to the bottom and with sufficient holes of required diameter. The panel should be painted with two coats of rust proof zinc chromate and two coats of anti corrosive epoxy shade 631 siemens grey paint after completion of de rusting process. Earth work excavation of foundation stench of size 1mX0.45mX0.6m and filling river sand for a depth of 10cm and PCC 1:2:4 of size 1X0.45X0.50m. The cost should be inclusive of minor modification suitable for site condition as approved by the engineer in charge.
1
-
-
... More
Code no:10.28 Providing and fixing AISI 316 grade stainless steel hand rail of 50mm (outer dia 2mm wall thickness) stainless steel pipe supported on 40x10mm stainless steel flat at 600mm centre to centre to a toatl height of 900mm from the finished floor level and fixing 4nos .of 25mm (outer dia and 2mm wall thickness) stainless steel pipe as guard rails through the S.S.flat ,with a base plate of size 100x100x8mm,including fixing in the base plate in concrete / wall surfaces by 4 nos of M-8 anchor fasteners and polishing the entire stainless steel work to no.4 surface finish as per the direction of engineer - in -charge
18
-
-
... More
Code no:10.27 Supplying and fixing of steel grill work of m.s. angles, flats ,squares and pipes in cluding cost of welding charges, fixing in position in masonry walls with cement concrete 1:2:4 (1 cement : 2 course sand : 4 graded stone aggregate 12.5mm nnominal size) including one coat of priming coat etc. complete.
500
-
-