Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.

Projects And Development India Limited - PDIL Tender

Works
Eprocure
Opening Date9 Jun 2023
Closing Date17 Jul 2023
Tender Amount₹ 35,99,50,000 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Summary

Grid Connectivity To Tfl To Supply 90 Mw Power Andconstruction Of 220 Kv Lilo Gis Attalcher Fertilizers Ltd

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
245kV, 3150A, 50kA (3 sec for CB & 1 sec for Disconnector,Grounding switch,CT,PT), SF6 gas insulated Transformer feeder bay module each comprising of SF6 gas insulated circuit breaker, current transformer, bus-bar dis connectors with common grounding switch, Motorised dis connectors with safety grounding switch(es), high speed fault making motorised grounding switch, Stand alone Local control cubicle, SF6 gas monitoring system for complete bay, SF6 bus duct termination arrangement, PD sensor (adequate number of UHF sensors in the offered GIS equipment for detection of Partial discharge (of 5 pC and above) as per IEC 60270 through Partial Discharge (PD) monitoring system), different gas compartment, O- ring & gaskets,Nuts, Bolts & Washers Absorbent,Limit Switch ,SF6 Gas , etc to complete Transformer feeder bay module & its earthing arrangement with earthing strips of adequate size as per the technical specification.

1

-

-

... More
245kV, 3150A,50kA (3 sec for CB & 1 sec for Disconnector,Grounding switch,CT & PT), SF6 gas insulated Line feeder bay module each comprising of SF6 gas insulated circuit breaker, current transformer,Line Potential Transformer (3 core), bus-bar dis connectors with common grounding switch, Motorised dis connectors with safety grounding switch(es), high speed fault making motorised grounding switch, Stand alone Local control cubicle, SF6 gas monitoring system for complete bay, SF6 bus duct termination arrangement,PD sensor (adequate number of UHF sensors in the offered GIS equipment for detection of Partial discharge (of 5 pC and above) as per IEC 60270 through Partial Discharge (PD) monitoring system), different gas compartment, O- ring & gaskets,Nuts, Bolts & Washers Absorbent,Limit Switch ,SF6 Gas , etc to complete line feeder bay module & its earthing arrangement with earthing strips of adequate size as per the technical specification.

4

-

-

... More
245kV , 3150A, 50 kA ( 3 sec for Bus bar ,1 sec for disconnector,grounding switch & bus P.T), 3- phase Isolated , SF6 gas insulated , Metal enclosed bus bars each enclosed in bus enclosures running along the length of the switchgear to interconnect each of circuit breaker bay module. Each bus bar set shall be complete with bus potential transformer (3 core), dis connectors , bus bar grounding switch, SF6 gas monitoring system PD sensor (adequate number of UHF sensors in the offered GIS equipment for detection of Partial discharge (of 5 pC and above) as per IEC 60270 through Partial Discharge (PD) monitoring system), different gas compartment, O- ring & gaskets,Nuts, Bolts & Washers Absorbent,Limit Switch ,SF6 Gas , etc to complete the bus & its earthing arrangement with earthing strips of adequate size (as per IEEE-80-2000 and CIGRE44 to protect operating staff against any hazardous touch voltages and electro-magnetic interferences) as per the technical specification.

2

-

-

... More
SF6 gas insulated Bus Coupler Bay Module comprising of SF6 gas insulated circuit breaker, current transformer, dis connectors switches, disconnector with safety grounding switch(es). Local control cubicle, SF6 gas monitoring system, PD sensor (adequate number of UHF sensors in the offered GIS equipment for detection of Partial discharge (of 5 pC and above) as per IEC 60270 through Partial Discharge (PD) monitoring system), different gas compartment, O- ring & gaskets,Nuts, Bolts & Washers Absorbent,Limit Switch ,SF6 Gas , etc to complete Bus Coupler bay module & its earthing arrangement with earthing strips of adequate size (as per IEEE-80-2000 and CIGRE44 to protect operating staff against any hazardous touch voltages and electro-magnetic interferences) as per the technical specification.

1

-

-

... More
245kV, 3150A, 50kA, 3 sec, single phase, SF6 gas Insulated Bus Duct outside GIS Hall alongwith associated Support structure arrangement bends, joints,accessories, & its earthing arrangement with earthing strips of adequate size (as per IEEE-80-2000 and CIGRE44 to protect operating staff against any hazardous touch voltages and electro-magnetic interferences) as per the technical specification etc.

480

-

-

... More
245kV, 3150A, 50kA SF6/Air Bushing ( Bushing shall be of Polymer / composite insulator type and shall be seamless sheath of a silicone rubber compound. The hollow silicone composite insulators shall comply as per IEC 61462 and the relevant parts of IEC 62217. The design of the composite insulators shall be tested and verified according to IEC 61462 ).

15

-

-

... More
Portable Partial Discharge(PD) monitoring system: 245kV system shall have Portable Partial Discharge(PD) monitoring system & shall be capable for measuring PD in charged GIS environment ,bandwidth in order of 100 MHz–2GHz & provision to select a wide range of intermediate bandwidths and the principle of operation shall be based on UHF principle of detection. The Detection and measurement of PD and bouncing particles having in built large coloured LCD for displaying and storing facility in the instrument for further analysis to locate actual source of PD such as free conducting particles, floating components, voids in spacers, particle on spacer surfaces etc.

1

-

-

... More
250kVA , 380BHP, 220kW, Silent AMF Diesel Generator set, 1500 rpm with AMF control panel as per Technical Specification.

1

-

-

... More
220kV OUTDOOR EQUIPMENTS:

-

-

-

... More
245kV,50kA/1Sec, 1 Core, CL-0.2, 50VA Single Phase Potential Transformer (AIS) for Metering

6

-

-

... More
PT Console Box for above PTs as above

2

-

-

... More
245kV,50kA/1Sec, 5 Core, 1200-600-300/1A, CL-PX,0.2S, 30VA Single Phase Current Transformer (AIS) for Metering

6

-

-

... More
CT Console Box for above CTs as above

2

-

-

... More
245kV,3150A,50kA/1sec, Double Break Isolator (Isolator with earth switch including post insulators for incomer)

2

-

-

... More
220kV, Cable Sealing End (220kV GIS END )

6

-

-

... More
220kV, Cable GIS end termination kit at (MRSS Substation End)

6

-

-

... More
216kV Metal Oxide Surge Arrestor, 10kA, Long duration discharge class III, 10kJ/kV at 216kV as per technical Specification

15

-

-

... More
33kV OUTDOOR EQUIPMENTS:

-

-

-

... More
33kV, 1250A, 31.5kA/3s, 3 Phase, Outdoor Vaccum Circuit breaker with Supporting Structure

4

-

-

... More
33kV Single Phase Current Transformer for 20MVA Power transformer, 5 core, ratio: 800-400-200/1A

3

-

-

... More
CT Console Box for above CTs

1

-

-

... More
33kV Single Phase Current Transformer for 33kV Feeder & 33kV Buscoupler, 3 core, ratio: 800-400-200/1A

9

-

-

... More
CT Console Box for above CTs

3

-

-

... More
33kV Single Phase, Bus Potential Transformer, 2 core (0.2,3P classes), 33kV/110V/110V

3

-

-

... More
PT Console Box for above PTs

1

-

-

... More
33kV Single Phase, Metering Current Transformers for 33kV feeder bays, 1 core, 800-400-200/1A

6

-

-

... More
CT Console Box for above CTs as above

2

-

-

... More
33kV Single Phase, Metering Potential Transformers for 33kV feeder bays, 1 core, 33kV/110V

6

-

-

... More
PT Console Box for above PTs

2

-

-

... More
33kV, 1250A, 31.5kA/1s, Outdoor Isolator W/O Earth Switch

8

-

-

... More
33kV, 1250A, 31.5kA/1s, Outdoor Isolator with Earth Switch

5

-

-

... More
33kv, 200A, Horn Gap fuses

2

-

-

... More
30kV Metal Oxide Surge Arrestor, 10kA, Long duration discharge class III as per technical Specification.

15

-

-

... More
33kV Bus Post Insulator

10

-

-

... More
Tariff Meter for Main & Check meter for Metering

8

-

-

... More
XLPE Power Copper conductor cable for the GIS system (36kV class) and cable termination kit

-

-

-

... More
36kV XLPE Cable 300 sq. mm Copper Single Core (from 33kV side TFL feeder End termination to 33kV Double pole structure having each phase one run)

0.85

-

-

... More
36kV Outdoor type termination Kits (from TFL feeder to 33kV Double pole structure) suitable for 1CX300 Sq.mm

12

-

-

... More
BUS BAR & CIRCUIT MATERIALS

-

-

-

... More
Long Rod Silicon Composite Insulator

-

-

-

... More
160kN Long rod Insulator strings for 245kV tension purpose

6

-

-

... More
160kN Long rod Insulator strings for 245kV Suspension purpose

6

-

-

... More
120kN Long rod Insulator strings for 33kV tension purpose

36

-

-

... More
90kN Long rod Insulator strings for 33kV Suspension purpose

30

-

-

... More
Single ACSR Moose Conductor:

0.95

-

-

... More
HARDWARES & FITTINGS/SPACERS/CLAMP & CONNECTORS

-

-

-

... More
220kV Single Tension H/W fitting for single moose ACSR

6

-

-

... More
220kV Single Suspension H/W fitting for single moose ACSR

6

-

-

... More
Clamps & Connectors etc: 220kV T- clamp for ACSR ZEBRA to ACSR MOOSE drop,220kV Isolator pad clamp suitable for ACSR Moose conductor,3 bolted PG clamp suitable for ACSR Moose conductor,220kV LA Clamp suitable for ACSR Moose, 30kV LA Clamp suitable for ACSR Moose. etc as required.

-

-

-

... More
Terminal connector for power transformer to receive ACSR conductor suitable for horizontal take off

3

-

-

... More
Terminal connector for Isolator to receive ACSR conductor suitable for horizontal take off

12

-

-

... More
Terminal connector for LA to receive ACSR conductor suitable for horizontal take off

15

-

-

... More
Terminal connector for CT to receive ACSR conductor suitable for horizontal take off

6

-

-

... More
Terminal connector for CVT to receive ACSR conductor suitable for horizontal take off

6

-

-

... More
Terminal connector for Cable sealing End to receive ACSR conductor suitable for horizontal take off for 220kV GIS End

6

-

-

... More
Terminal connector for SF6 Air bushing to receive ACSR conductor suitable for horizontal take off

15

-

-

... More
Clamps & Connectors etc: 33kV Equipments for ACSR MOOSE.

-

-

-

... More
Terminal connector for power transformer to receive ACSR conductor suitable for horizontal take off

3

-

-

... More
Terminal connector for Isolator to receive ACSR conductor suitable for horizontal take off

78

-

-

... More
Terminal connector for LA to receive ACSR conductor suitable for horizontal take off

15

-

-

... More
Terminal connector for CT to receive ACSR conductor suitable for horizontal take off

18

-

-

... More
Terminal connector for CB to receive ACSR conductor suitable for horizontal take off

24

-

-

... More
Terminal connector for PT to receive ACSR conductor suitable for horizontal take off

9

-

-

... More
Terminal connector for station transformer to receive ACSR conductor suitable for horizontal take off

6

-

-

... More
Terminal connector for HG Fuse to receive ACSR conductor suitable for horizontal take off

12

-

-

... More
Spacer for Twin Bus ACSR 33kV Bus

100

-

-

... More
Substation Earthing Systems:

-

-

-

... More
Earthing Conductor for Burrial : 75X10mm GI Flat for Earthing conductor for Main Mat and Below Ground Riser

30.1

-

-

... More
Earthing Conductor; 75X10mm Gl (HDG) Flat for Raiser from the burial earth mat to outdoor equipments, structure, building lightning protection etc)

5.9

-

-

... More
Earthing Conductor; 50X6mm Gl (HDG) Flat for Raiser for Console box, LT Panels, DC Panels, Marshalling boxes etc.

1.08

-

-

... More
Earthing device & Associated Accessories (50 mm heavy duty Gl PERFORATED Pipe 3 mtrs long for treated earth pit)

58

-

-

... More
Earthing device & Associated Accessories 40 mm MS rod 3 mtrs long for non-treated earth pit

12

-

-

... More
Earthing Spikes and Its Fittings in all respect.

-

-

-

... More
Earthing Spikes of 2 mtr long each Gl pipe & other accessories and Its Fittings in all respect. (for 220 & 33kV side column gantry)

3

-

-

... More
Switchyard building lightning protection (all materials & accessories like Shielding Wire, PG clamp, Test link, D shackle etc) as per IS/National Building code standard

-

-

-

... More
20x3mm copper Flat for horizontal and down conductor

310

-

-

... More
10mm dia 1000mm Long Air Termination Spike

8

-

-

... More
GS Fixing Clamps for 20x3mm Copper Conductor

210

-

-

... More
Test Joint

6

-

-

... More
G.I Cable Trays including support GI angle suitable for different sections along with its accessories as per TS. Details of No. of tiers are indicated in the TS-Civil Section accordingly the requirement can be ascertained & High Quality ISI mark PVC-U selfit Pipe, PVC elbow bend, PVC Tee etc suitable for under ground burrial (Hard Conduit Including of adequate tensile strength minimum 7kg/sqmm or better) as per TS.

-

-

-

... More
G.I Cable Trays(size: 450x75x2500mm)

138

-

-

... More
G.I Cable Trays(size: 300x75x2500mm)

55

-

-

... More
G.I Cable Trays(size: 150x75x2500mm)

65

-

-

... More
Support G. I angle 50x50x6 mm including 6mm MS plate for cable tray

2.6

-

-

... More
100mm dia PVCPipe

30

-

-

... More
50mm dia PVC Pipe

20

-

-

... More
Sub Station Switchyard BMK, AC Console & Other MB as per Tech Spec.

-

-

-

... More
Switchyard AC Console for Lighting

2

-

-

... More
Switchyard Receptacle Board for TFR Oil Filteration (01 no. near 220/33kV Power transformer)

1

-

-

... More
Switchyard Receptacle Board for Welding & Other Emergency Nature Work

1

-

-

... More
33kV switchyard Bay Marshalling Kiosk

2

-

-

... More
Lighting cum Lightning Mast ( Including Foundation bolts) for 220/33kV Class

-

-

-

... More
Supply of Lighting cum Lightning Mast including LED lighting fixtures (Excluding 30 Mtr. Monopole) with control gear panel etc suitable for wind zone-V , with all other accessories like motor for hoisting/lowering the lighting platform & other switchgear and lighting control panel etc. for 30 Mtrs. height Monopole (HDG)

2

-

-

... More
30 Mtrs height Monopole (HDG) for Lighting cum Lightning Mast structure suitable for wind zone-V (2 Nos.)

36

-

-

... More
General Equipment & Substation Accessories: Supply of Power and control cable including fixing of cable with terminal connections both at equipments and control panels with supply of and fixing of lugs, Ferrules, clamps, connectors, glands, fixing of cable trays, including supply of N&B, Link plates, Cable Markers, Plaster of Paris, M-Seal Compounds etc., for sealing purposes and all neccessary arrangments, Supply of Earthing Flats, Earthing, laying of Cable trench slabs and chequered plate etc., for the cable trench, Cable scheduled and cable diagram to be prepared by the Contractor.

-

-

-

... More
Power Cables, 1.1kV, XLPE & PVC Armoured, Aluminium Conductor (As per Specification) including power cable termination, Lugs, Glands & other materials in order to complete the activity.

-

-

-

... More
3.5CXI85 mm² XLPE

180

-

-

... More
3.5CX120 mm² XLPE

100

-

-

... More
3.5CX70 mm² PVC

260

-

-

... More
3.5CX35 mm² PVC

300

-

-

... More
4CX 16 mm² PVC

884

-

-

... More
4CX 6 mm2 PVC

300

-

-

... More
2CX 6 mm2 PVC

1569

-

-

... More
Control Cables, 1.1kV, PVC Armoured Stranded Copper (As per specification) including control cable termination, Lugs, Glands & other materials in order to complete the activity.

-

-

-

... More
5CX 2.5 mm2

6078

-

-

... More
10CX 2.5 mm2

1682

-

-

... More
12CX 2.5 mm2

3722

-

-

... More
16CX 2.5 mm2

1180

-

-

... More
19CX 2.5 mm2

2130

-

-

... More
1CX 120 mm2 Bat to Bat Charger & Charger to DCDB

90

-

-

... More
SUPPLY OF STATION TRANSFORMER& OTHER MATERIALS FOR MEETING THE AUXILIARY SUPPLY OF THE SUBSTATION AS PER TECHNICAL SPECIFICATION

-

-

-

... More
STATION TRANSFORMER 33KV/0.43 KV,250 KVA (AS PER SPECIFICATION)

2

-

-

... More
SUB STATION LIGHTING (AS PER SPECIFICATION AND APPROVED DRAWINGS)(includes switchyard street area)

-

-

-

... More
Indoor Lighting:

-

-

-

... More
220kV GIS Building Indoor Lighting, it includes supply of fixtures & lamps (LED) of OPTCL approved Make with switchgear, Conduit & other required materials for succesful illumination of the area/rooms. (No. of LED Lighting fixtures are to be calculated based on the illumination design considering the required lux level indicated in the technical spec & fixing of the same rigidly on the suitable height either ceiling & wall as required.) (i) 150W High bay LED of OPTCL approved make

1

-

-

... More
Control room building indoor Lighting, it includes supply of fixtures & lamps (LED) of OPTCL approved make with switch gear, Conduit & other required materials for succesful illumination of the area/rooms.( No. of LED Lighting fixtures are to be calculated based on the illumination design considering the required lux level indicated in the technical spec & fixing of the same rigidly on the suitable height either ceiling & wall as required.) (i) Surface Mounted LED 42W of OPTCL approved make (ii) 34W LED Lights of OPTCL approved make ( for control room) (iii)36W LED Corrossion Proof Luminaire with IP65 Protection suitable for dusty & Corrossive atmosphere of OPTCL approved make for battery room.

1

-

-

... More
Indoor Lighting OF Security Shed cum Visitors room, FFPH Building, Store Shed, Parking shed: It includes supply of fixtures & lamps (LED) of OPTCL approved make with switch gear,Conduit & other required materials for succesful illumination of the area/rooms. (No. of LED Lighting fixtures are to be calculated based on the illumination design considering the required lux level indicated in the technical spec & fixing of the same rigidly on the suitable height either ceiling & wall as required.) (i) 34W LED Lights of OPTCL approved make ( for control room)

1

-

-

... More
Outdoor Lighting:

-

-

-

... More
Sub-Station Switchyard Lighting, it includes Supply of fixtures & lamps (LED) of OPTCL approved Make with switchgear,GI Conduit etc.(Lighting fixtures are to be fixed rigidly on the Column at a suitable height so that the required lux can be achieved).(150 watt each)

12

-

-

... More
Street Lighting: GI Tubular Pole: (410-SP-24: IS 2713-Part-II-1980 or latest) Length of pole 8.5 mtrs(minimum weight 158 Kgs). & LED light fittings etc. (All the Street Light Pole Shall be of GI Tubular Pole and provision of a GI Junction box with Suitable Covers at a height of 1 Metre from the Ground. The Junction Box shall have Provision of Fuses, Buses, Connectors for cable in and out. ( It Includes Supply of LED Lighting Fixtures with Lamps of 100Watts of OPTCL approved make & as per technical specification).

18

-

-

... More
Outdoor Kiosk for Street Lighting Purpose having 2 Nos. 200Amp Switch Fuse Units and , 6 Nos. outlets of 32Amp MCB For Street Lighting. (Suitable For XLPE Cables (3.5C X 120Sqmm) from Main ACDB from Control Room to the Outdoor Kiosk. XLPE Cable Of 4C X 16Sqmm from Outdoor Kiosk to the Street Light Poles and 4C X 6Sq.mm from Pole to Pole and 2C X 6Sq.mm from Pole to Lighting Fixtures. 1 No. Outdoor Kiosk for Colony Supply Purpose (* Remarks: For Supply of All the Cables As Indicated Are Covered In the Cable Items As Indicated Above)

1

-

-

... More
Outdoor Kiosk for Street Lighting Purpose having 2 Nos. 200Amp Switch Fuse Units and , 6 Nos. outlets of 32Amp MCB For Street Lighting. (Suitable For XLPE Cables (3.5C X 120Sqmm) from Main ACDB from Control Room to the Outdoor Kiosk. XLPE Cable Of 4C X 16Sqmm from Outdoor Kiosk to the Street Light Poles and 4C X 6Sq.mm from Pole to Pole and 2C X 6Sq.mm from Pole to Lighting Fixtures. 1 No. Outdoor Kiosk for Colony Supply Purpose (* Remarks: For Supply of All the Cables As Indicated Are Covered In the Cable Items As Indicated Above)

12

-

-

... More
220kV GIS hall-ventilation system through ducting (Pressurization type ventilation system) at AHU room as per technical specification

1

-

-

... More
Fire Fighting System (Portable /Trolley/ Wheel Mounted Fire Extinguishers sets for Control Room, Equipment like Transformer and other areas as per Tech Spec.

-

-

-

... More
Foam Type-9 Ltrs

4

-

-

... More
Dry Chemical Powder (Trolley Mounted)- 22.5Kgs

4

-

-

... More
Dry Powder Type - 5Kgs

4

-

-

... More
Co₂- 4.5Kgs

10

-

-

... More
CO₂ - 9Kgs

10

-

-

... More
CO₂ (Trolley Mounted)- 22.5Kgs

4

-

-

... More
Fire Bucket (6 Nos in each stand) with stand

5

-

-

... More
9 litre water type

4

-

-

... More
4.5 kg DCP type

4

-

-

... More
50 Litres Mechanical Foam type

2

-

-

... More
Supply of Smoke & Heat detection system: Addressable optical Smoke & Heat Multi detector( 50 Nos) for main control room building including all accessories, Main control panel(Microprocessor based 2 loop fire alarm control panel expandable upto 18 loops fully networkable with each loop capable of taking 99 devices, 8 line x 40 character alpha- numeric liquid crystal display .The panel shall be soft addressable type . The panel shall be able to give pin point location of all fire/fault conditions. Further, the panel must be able to automatically switch off respective control switches when ever any alarm is triggered. The panel shall have in built rectifier, Loop cards,provision for externel & internal printer(if required), L C D unit to indicate Fire/Fault Signal with address and analog output, built in printer to log all fire or fault events complete in all respects, integral SMF lead acid batteries with sealed cells of 24 V capable of running for a minimum of 8 hours with integral battery charger complete as required and as per specification. The fire alarm panel shall be suitable for software integration with BMS & PA system ,wall mounting loop powered addressable type hooter with all accessories , addressable manual call box made of polycarbonate with plastic break glass front and complete with monitor module MCB, addressable isolator module with required PVC box, fittings and fixtures, wiring with PVC FRLS wire to cover the required for fire & smoke detection etc. (One control room building & 1 no. GIS hall are to be provided with Heat & smoke detection). Should have facility for integration with SAS.

1

-

-

... More
Fire Fighting (HVW system & hydrant system) system with Detailed Design Suitable for 20MVA, 220/33kV Power Transformer etc., as per the Latest Standard & TS.

-

-

-

... More
Fire Fighting Equipment: (Main Pump, Jockey Pump, DG Set cum Pump, Control Panel for Fire Fighting System (HIGH PRESSURE : Hydrant and Mulsifire system) to take care of 1 No. 20 MVA, 220/33 KV POWER TRANSFORMER, switcyard equipment and buildings. HVW system & hydrant sytsem, complete with all piping, valves, fittings etc inside pump house for Fire protection sytem of substation) as per the technical spec & Latest standard.

1

-

-

... More
Hydrant pipe for Substation fire protection system

0.08

-

-

... More
Hydrant sytsem, complete U/G piping of different sizes,valves and accessories etc outside the Pump House for Fire protection sytem of 1 Nos. 20 MVA, 220/33 KV POWER TRANSFORMER, switcyard equipment and buildings as per the technical spec & Latest standard.

1

-

-

... More
HVW Spray sytsem, Hydrant System and complete U/G and O/G piping,different type of valves,Fire sensor etc and accessories etc near the Transformer for Fire protection of 1 No. 20 MVA, 220/33 KV POWER TRANSFORMER, as per the technical spec.

1

-

-

... More
Substation Automation System for 220/33kv Substation on Parallel redundacy protocol(PRP) mode: Design, Engineering, Drawing, Supervision, Installation, Testing & Commissioning of Substation Automation System along with Supply of the following 220 And 33kV level of Protection Panels consisting of Bay Control Units & Numerical Protection Relays and other Auxiliary Relays Suitable for SAS as Per Technical Specification. NOTE: All Protective Relays & BCU Shall Be Numerical Type.

-

-

-

... More
Gate way panel for Sub-Station Automation (in PRP as per the specification & indicative drg ) system (for All 220 & 33 KV side bays including the future bays),other accessories (comprising servers, engg. Station, works station (Main & standby), Remote station control, Colour Laser jet Printers & dot matrix printer for local station as per requirement and also for remote station, Ethernet Switches , LIU, Red Box, Multimode glass fibre Doublle jacket armoured optical cables, special cables like F.O patch cord & armoured FO cables of adequate length etc required for the system in all respect as per latest IEC 61850 standard, Inverters of required capacity & rating (Input shall be both A.C & D.C and output shall be A.C) etc as per TS. A large vedio screen of 60 inches for display including all type of accessories & as per technical specification.

1

-

-

... More
BCU for Substation Auxilliary System (Station AC, Station DC, Lighting, Fire fighting, Diesel generator etc. as per the site requirement)

1

-

-

... More
220 KV PROTECTION PANELS

-

-

-

... More
Feeder Protection panel (Main-I , Main-II & Back-up protection with auto reclosure Distance Protection) with Bay control unit (BCU) for substation automation system. (Simplex with front Glass door)

4

-

-

... More
Transformer Protection Panel (Differential I & II , REF I & II & Back-up Protection for HV & LV side Considering HV & LV side of 220/33kV, 20MVA) with Bay control units (BCU) for HV & LV for substation automation system. (Simplex with front Glass door)

1

-

-

... More
Bus Coupler Protection Panel with Bay control unit (BCU) for substation automation system. (Simplex with front Glass door)

1

-

-

... More
Bus-Bar Protection Panel (Provision of bus bar modules for the future bays and to be integrated with the Automation system) (Simplex with front Glass door).

1

-

-

... More
87L (Line differential relay) Numerical Relay for remote End Station

2

-

-

... More
33 KV PROTECTION PANELS

-

-

-

... More
33kV Feeder Protection Panel with Bay control Protection unit (BCPU) for substation automation system

2

-

-

... More
33kV Transformer Protection Panel with Bay control Protection unit (BCPU) for substation automation system (33kV side of 220/33kV, 20MVA)

1

-

-

... More
33kV Transfer Bus Coupler Protection Panel with Bay control Protection unit(BCPU) for substation automation system.

1

-

-

... More
AC & DC SYSTEM

-

-

-

... More
AC SYSTEM

-

-

-

... More
Main ACDB, Facilities for integration with SAS as per the site requirement, as per specification

1

-

-

... More
ACDB as per Technical Specification.

1

-

-

... More
Main Lighting Distribution Board as per Technical Specification

1

-

-

... More
Indoor Lighting Distribution board as per Technical Specification

1

-

-

... More
Emergency Lighting Distribution Board

1

-

-

... More
Indoor Receptacle Board

2

-

-

... More
220V & 48V DC System:

-

-

-

... More
220V DC BOARD (Having 100A DC MCCB as Incomer , E/F (Earth Leakage), Under & Over Voltage as per Specification (DCDB-1,DCDB-2 & B/C). Consider Separate Source (DC1 & DC 2) to each panels & accordingly sufficient Nos. of DC output from DB-1 & 2 to be considered. Facilities for integration with SAS as per the site requirement.

1

-

-

... More
220V DC Emergency Distribution Board

1

-

-

... More
Battery (350AH PLANTE type) for 220V DC

2

-

-

... More
Battery Charger for 350AH, 220V DC (Float & Float cum Boost) (including provision of series dropper diodes with heat sinks & other protection facility at the DC Load terminal end in order to feed 220V to the load).Facilities for integration with SAS as per the site requirement.

2

-

-

... More
DE MINERALISED PLANT of 30 L/Hr for making Distilled water for battery banks

1

-

-

... More
48V DC BOARD (Having 75A DC MCCB as Incomer , E/F (Earth Leakage), Under & Over Voltage as per Specification (DCDB-1,DCDB-2 & B/C). Consider Seprate source (DC1 & DC2)to each panels & accordingly sufficient Nos. of DC output from DB-1 & DB-2 to be considered. Facilities for integration with SAS as per the site requirement.

1

-

-

... More
48V, 300 AH, VRLA type battery set

2

-

-

... More
SMPS based battery charger for 48V, 75A float cum boost (as recommended by the Battery manufacturer)

2

-

-

... More
Accessories for FOTE / OPGW System as per technical specification:

-

-

-

... More
24 Fibre (DWSM) OPGW fibre optic cable

0.1

-

-

... More
OPGW hardware set like suspension assembly, Tension Assembly (Dead end assembly, pass through assembly), vibration damper, down lead assemblies for 24/48 fibre (DWSM) OPGW, Joint box

1

-

-

... More
Optical line terminal equipment (OLTE)-STM4 type SDH equipment with integrated MUX & tributary cards for speech & data ports for interfacing of speech & data which should be compatible with existing OPTCL system.

1

-

-

... More
Supply of FODP (Fibre optic Distribution panel) 48 F: Indoor type, rack mounted with FCPC coupling and pigtails (DWSM fibre)

1

-

-

... More
Digital tele-protection coupler compatible for interfacing with SDHMUX

1

-

-

... More
Earth flat, cable tray, telephone cable, ACDB, DCDB, foundation rail, Junction Box, Cat 5 cable & Misc items

1

-

-

... More
EOT Crane for GIS building for 220kV GIS station (5T Capacity safe working load & minimum height of crane have shall be 8.0 meters or as per actual requirement whichever is higher. The crane shall have minimum speeds under full load of: Speed (a) Hoisting 2 meters/minute (b) Cross Travel 10 meters/minute (c) Long Travel 20 meters/minute (d) Creep speed shall be of 25% of operating speed.The crane shall be possible to be operated through the cable, through the pendant control and which shall be easily accessible from the floor of GIS building and through remote control device. ) including all accessories with control panel.

1

-

-

... More
MANDATORY SPARE: Being Quoted Separatly as listed from 117 of this BOQ

-

-

-

... More
GENERAL TOOLS & TACKLES - As per Annexure A of Part-36 of Technical Specifications

1

-

-

... More
MAINTENANCE TESTING EQUIPMENTS - As per Annexure B of Part-36 of Technical Specifications

1

-

-

... More
OFFICE FURNITURE - As per Annexure C of Part-36 of Technical Specifications

1

-

-

... More
Best Quality & approved make Insulating Mat (Confirming to IS:15652:2006) to be kept infront of all Panels, Boards etc., (2000X1000X3)mm Size

40

-

-

... More
DIFFERENT TYPE OF LATICE TYPE COLUMNS WITH DETAILS & DIFFERENT TYPE OF BEAMS WITH DETAILS

-

-

-

... More
(Tower) 220kV COLUMN: P1S TYPE,- HEIGHT-21.5 MTRS

14

-

-

... More
(Girder) 220kV BEAM:Q1 TYPE,-LENGTH-18 MTRS

3

-

-

... More
(Tower) 33kV COLUMN, HEIGHT-8 MTRS

9.7

-

-

... More
(Girder) 33kV BEAM:G1 TYPE,-LENGTH-5.5 MTRS

4.15

-

-

... More
SUPPORT STRUCTURES FOR OUDOOR EQUIPMENTS

-

-

-

... More
SUPPORT STRUCTURES FOR 220kV EQUIPMENT

-

-

-

... More
220kV Isolator

7

-

-

... More
220kV Surge Arrester

4

-

-

... More
220kV Current transformer

1.5

-

-

... More
220kV Potential transformer

1.2

-

-

... More
220kV Cable sealing end

1.5

-

-

... More
SF6 Bushing

4.5

-

-

... More
SUPPORT STRUCTURES FOR 33kV EQUIPMENT

-

-

-

... More
33 KV Lightning Arrestor

0.7

-

-

... More
33 KV Current Transformer

1.5

-

-

... More
33 KV Bus Potential Transformer

0.3

-

-

... More
33 KV Metering Current Transformer

0.6

-

-

... More
33 KV Metering VoltageTransformer

0.6

-

-

... More
33 KV Bus Post Insulator

3

-

-

... More
33 KV Horn Gap Fuse

0.64

-

-

... More
33 KV Isolator

2.32

-

-

... More
33 KV Isolator with ES

1.6

-

-

... More
Cable End Termination

0.8

-

-

... More
Gl bolts ,Nuts, washers plain & spring etc for the above structures

2.18

-

-

... More
GI Foundation bolts & nuts with plate & other washers as required

3.95

-

-

... More
Triple Pole Structure for Double circuit 33kV Line: 3 Nos. Galvanized H-Type 14 Mtr. Structure including Channels, Angles and Flat for Belting, Bracing, mounting and termination of 6 Nos. 33kV Single core cable. This also includes supply of Lightning Arrestors, GO AB Switch, Polymer Pin & Disc Insulators incl. Hardware fittings, Complete Stay Ser, Earthing arrangement, HDPE Pipes from Ground Level to a Suitable Height on the Pole etc. to terminate the 33kV Cable on the structure complete. Note: Stringing of 148 Sq.mm. AAA Conductor from this Gantry to TFL Pump House is not included in above.

1

-

-

... More
220kV XLPE Cable Package (220kV GIS station to MRSS station):

-

-

-

... More
220kV XLPE copper Cable 1Cx1000 sq.mm Single Core (from 220kV GIS station side to MRSS Station having each phase one run)

4.45

-

-

... More
24 Fibre (DWSM) OPGW fibre optic cable

1.5

-

-

... More
installation hardware for 24 fibre optic cable

1

-

-

... More
50mm DIA PVC PIPE / 40mm DIA PLB DUCT (OPTICAL FIBER CABLE)

1.5

-

-

... More
Supply of 220kV XLPE cable straight through joint kit complete suitable for cable with Link boxes

6

-

-

... More
Supply of Cross bonding & Link Boxes for Earthing

2

-

-

... More
Supply of 2 TR Capacity Split Air Conditioning Units (Inverter type latest model) of OPTCL approved make.

12

-

-

... More
SCHEDULE-2B-SS (Erection)

-

-

-

... More
220/33kV, 20MVA, YNyn0, 3 phase Power Transformer Complete in all respect.

1

-

-

... More
Short Circuit Testing of 220/33kV, 20MVA, YNyn0, 3 phase Power Transformer at any Govt. Lab in India

1

-

-

... More
245kV GIS EQUIPMENT as per latest IEC standard & type tested equipment as per technical specification, with open future proof & flexible system in line with IEC 61850 & IEC 62271-203. (Circuit breaker shall be C2 - M2 class as per IEC 62271-100).

-

-

-

... More
245kV, 3150A, 50kA (3 sec for CB & 1 sec for Disconnector,Grounding switch,CT,PT), SF6 gas insulated Transformer feeder bay module each comprising of SF6 gas insulated circuit breaker, current transformer, bus-bar dis connectors with common grounding switch, Motorised dis connectors with safety grounding switch(es), high speed fault making motorised grounding switch, Stand alone Local control cubicle, SF6 gas monitoring system for complete bay, SF6 bus duct termination arrangement, PD sensor (adequate number of UHF sensors in the offered GIS equipment for detection of Partial discharge (of 5 pC and above) as per IEC 60270 through Partial Discharge (PD) monitoring system), different gas compartment, O- ring & gaskets,Nuts, Bolts & Washers Absorbent,Limit Switch ,SF6 Gas , etc to complete Transformer feeder bay module & its earthing arrangement with earthing strips of adequate size as per the technical specification.

1

-

-

... More
245kV, 3150A,50kA (3 sec for CB & 1 sec for Disconnector,Grounding switch,CT & PT), SF6 gas insulated Line feeder bay module each comprising of SF6 gas insulated circuit breaker, current transformer,Line Potential Transformer (3 core), bus-bar dis connectors with common grounding switch, Motorised dis connectors with safety grounding switch(es), high speed fault making motorised grounding switch, Stand alone Local control cubicle, SF6 gas monitoring system for complete bay, SF6 bus duct termination arrangement,PD sensor (adequate number of UHF sensors in the offered GIS equipment for detection of Partial discharge (of 5 pC and above) as per IEC 60270 through Partial Discharge (PD) monitoring system), different gas compartment, O- ring & gaskets,Nuts, Bolts & Washers Absorbent,Limit Switch ,SF6 Gas , etc to complete line feeder bay module & its earthing arrangement with earthing strips of adequate size as per the technical specification.

4

-

-

... More
245kV , 3150A, 50 kA ( 3 sec for Bus bar ,1 sec for disconnector,grounding switch & bus P.T), 3- phase Isolated , SF6 gas insulated , Metal enclosed bus bars each enclosed in bus enclosures running along the length of the switchgear to interconnect each of circuit breaker bay module. Each bus bar set shall be complete with bus potential transformer (3 core), dis connectors , bus bar grounding switch, SF6 gas monitoring system PD sensor (adequate number of UHF sensors in the offered GIS equipment for detection of Partial discharge (of 5 pC and above) as per IEC 60270 through Partial Discharge (PD) monitoring system), different gas compartment, O- ring & gaskets,Nuts, Bolts & Washers Absorbent,Limit Switch ,SF6 Gas , etc to complete the bus & its earthing arrangement with earthing strips of adequate size (as per IEEE-80-2000 and CIGRE44 to protect operating staff against any hazardous touch voltages and electro-magnetic interferences) as per the technical specification.

2

-

-

... More
SF6 gas insulated Bus Coupler Bay Module comprising of SF6 gas insulated circuit breaker, current transformer, dis connectors switches, disconnector with safety grounding switch(es). Local control cubicle, SF6 gas monitoring system, PD sensor (adequate number of UHF sensors in the offered GIS equipment for detection of Partial discharge (of 5 pC and above) as per IEC 60270 through Partial Discharge (PD) monitoring system), different gas compartment, O- ring & gaskets,Nuts, Bolts & Washers Absorbent,Limit Switch ,SF6 Gas , etc to complete Bus Coupler bay module & its earthing arrangement with earthing strips of adequate size (as per IEEE-80-2000 and CIGRE44 to protect operating staff against any hazardous touch voltages and electro-magnetic interferences) as per the technical specification.

1

-

-

... More
245kV, 3150A, 50kA, 3 sec, single phase, SF6 gas Insulated Bus Duct outside GIS Hall alongwith associated Support structure arrangement bends, joints,accessories, & its earthing arrangement with earthing strips of adequate size (as per IEEE-80-2000 and CIGRE44 to protect operating staff against any hazardous touch voltages and electro-magnetic interferences) as per the technical specification etc.

480

-

-

... More
245kV, 3150A, 50kA SF6/Air Bushing ( Bushing shall be of Polymer / composite insulator type and shall be seamless sheath of a silicone rubber compound. The hollow silicone composite insulators shall comply as per IEC 61462 and the relevant parts of IEC 62217. The design of the composite insulators shall be tested and verified according to IEC 61462 ) For Coneecting GIS to AIS.

15

-

-

... More
Portable Partial Discharge(PD) monitoring system: 245kV system shall have Portable Partial Discharge(PD) monitoring system & shall be capable for measuring PD in charged GIS environment ,bandwidth in order of 100 MHz–2GHz & provision to select a wide range of intermediate bandwidths and the principle of operation shall be based on UHF principle of detection. The Detection and measurement of PD and bouncing particles having in built large coloured LCD for displaying and storing facility in the instrument for further analysis to locate actual source of PD such as free conducting particles, floating components, voids in spacers, particle on spacer surfaces etc.

1

-

-

... More
250kVA , 380BHP, 220kW, Silent AMF Diesel Generator set, 1500 rpm with AMF control panel as per Technical Specification.

1

-

-

... More
220kV OUTDOOR EQUIPMENTS:

-

-

-

... More
245kV,50kA/1Sec, 1 Core, CL-0.2, 50VA Single Phase Potential Transformer (AIS) for Metering

6

-

-

... More
PT Console Box for above PTs

2

-

-

... More
245kV,50kA/1Sec, 5 Core, 1200-600-300/1A, CL-PX,0.2S, 30VA Single Phase Current Transformer (AIS) for Metering

6

-

-

... More
CT Console Box for above CTs

2

-

-

... More
245kV,3150A,50kA/1sec, Double Break Isolator (Isolator with earth switch including post insulators for incomer)

2

-

-

... More
220kV, Cable Sealing End (220kV GIS END )

6

-

-

... More
220kV, Cable GIS end termination kit at (MRSS Substation End)

6

-

-

... More
216kV Metal Oxide Surge Arrestor, 10kA, Long duration discharge class III, 10kJ/kV at 216kV as per technical Specification

15

-

-

... More
33kV OUTDOOR EQUIPMENTS:

-

-

-

... More
33kV, 1250A, 31.5kA/3s, 3 Phase, Outdoor Vaccum Circuit breaker with Supporting Structure

4

-

-

... More
33kV Single Phase Current Transformer for 20MVA Power transformer, 5 core, ratio: 800-400-200/1A

3

-

-

... More
CT Console Box for above CTs

1

-

-

... More
33kV Single Phase Current Transformer for 33kV Feeder & 33kV Buscoupler, 3 core, ratio: 800-400-200/1A

9

-

-

... More
CT Console Box for above CTs

3

-

-

... More
33kV Single Phase, Bus Potential Transformer, 2 core (0.2,3P classes), 33kV/110V/110V

3

-

-

... More
PT Console Box for above PTs

1

-

-

... More
33kV Single Phase, Metering Current Transformers for 33kV feeder bays, 1 core, 800-400-200/1A

6

-

-

... More
CT Console Box for above CTs

2

-

-

... More
33kV Single Phase, Metering Potential Transformers for 33kV feeder bays, 1 core, 33kV/110V

6

-

-

... More
PT Console Box for above PTs

2

-

-

... More
33kV, 1250A, 31.5kA/1s, Outdoor Isolator W/O Earth Switch

8

-

-

... More
33kV, 1250A, 31.5kA/1s, Outdoor Isolator with Earth Switch

5

-

-

... More
33kv, 200A, Horn Gap fuses

2

-

-

... More
30kV Metal Oxide Surge Arrestor, 10kA, Long duration discharge class III as per technical Specification.

15

-

-

... More
33kV Bus Post Insulator

10

-

-

... More
Tariff Meter for Main & Check meter for Metering

8

-

-

... More
XLPE Power Copper conductor cable for the GIS system (36kV class) and cable termination kit

-

-

-

... More
36kV XLPE Cable 300 sq. mm Copper Single Core (from 33kV side TFL feeder End termination to 33kV Double pole structure having each phase one run)

0.85

-

-

... More
36kV Outdoor type termination Kits (from TFL feeder to 33kV Double pole structure) suitable for 1CX300 Sq.mm

12

-

-

... More
BUS BAR & CIRCUIT MATERIALS

-

-

-

... More
Long Rod Silicon Composite Insulator

-

-

-

... More
160kN Long rod Insulator strings for 245kV tension purpose

6

-

-

... More
160kN Long rod Insulator strings for 245kV Suspension purpose

6

-

-

... More
120kN Long rod Insulator strings for 33kV tension purpose

36

-

-

... More
90kN Long rod Insulator strings for 33kV Suspension purpose

30

-

-

... More
Single ACSR Moose Conductor:

0.95

-

-

... More
HARDWARES & FITTINGS/SPACERS/CLAMP & CONNECTORS

-

-

-

... More
220kV Single Tension H/W fitting for single moose ACSR

6

-

-

... More
220kV Single Suspension H/W fitting for single moose ACSR

6

-

-

... More
Clamps & Connectors etc: 220kV T- clamp for ACSR ZEBRA to ACSR MOOSE drop,220kV Isolator pad clamp suitable for ACSR Moose conductor,3 bolted PG clamp suitable for ACSR Moose conductor,220kV LA Clamp suitable for ACSR Moose, 30kV LA Clamp suitable for ACSR Moose. etc as required.

-

-

-

... More
Terminal connector for power transformer to receive ACSR conductor suitable for horizontal take off

3

-

-

... More
Terminal connector for Isolator to receive ACSR conductor suitable for horizontal take off

12

-

-

... More
Terminal connector for LA to receive ACSR conductor suitable for horizontal take off

15

-

-

... More
Terminal connector for CT to receive ACSR conductor suitable for horizontal take off

6

-

-

... More
Terminal connector for PT to receive ACSR conductor suitable for horizontal take off

6

-

-

... More
Terminal connector for Cable sealing End to receive ACSR conductor suitable for horizontal take off for 220kV GIS End

6

-

-

... More
Terminal connector for SF6 Air bushing to receive ACSR conductor suitable for horizontal take off

15

-

-

... More
Clamps & Connectors etc: 33kV Equipments for ACSR MOOSE.

-

-

-

... More
Terminal connector for power transformer to receive ACSR conductor suitable for horizontal take off

3

-

-

... More
Terminal connector for Isolator to receive ACSR conductor suitable for horizontal take off

78

-

-

... More
Terminal connector for LA to receive ACSR conductor suitable for horizontal take off

15

-

-

... More
Terminal connector for CT to receive ACSR conductor suitable for horizontal take off

18

-

-

... More
Terminal connector for CB to receive ACSR conductor suitable for horizontal take off

24

-

-

... More
Terminal connector for PT to receive ACSR conductor suitable for horizontal take off

9

-

-

... More
Terminal connector for station transformer to receive ACSR conductor suitable for horizontal take off

6

-

-

... More
Terminal connector for HG Fuse to receive ACSR conductor suitable for horizontal take off

12

-

-

... More
Spacer for Twin Bus ACSR 33kV Bus

100

-

-

... More
Substation Earthing Systems:

-

-

-

... More
Earthing Conductor for Burrial : 75X10mm GI Flat for Earthing conductor for Main Mat and Below Ground Riser

5100

-

-

... More
Earthing Conductor; 75X10mm Gl (HDG) Flat for Raiser from the burial earth mat to outdoor equipments, structure, building lightning protection etc)

1000

-

-

... More
Earthing Conductor; 50X6mm Gl (HDG) Flat for Raiser for Console box, LT Panels, DC Panels, Marshalling boxes etc., (450 Mtrs.)

450

-

-

... More
Earthing device & Associated Accessories (50 mm heavy duty Gl PERFORATED Pipe 3 mtrs long for treated earth pit)

58

-

-

... More
Earthing device & Associated Accessories 40 mm MS rod 3 mtrs long for non-treated earth pit

12

-

-

... More
Earthing Spikes and Its Fittings in all respect.

-

-

-

... More
Earthing Spikes of 2 mtr long each Gl pipe & other accessories and Its Fittings in all respect. (for 220 & 33kV side column gantry)

3

-

-

... More
Switchyard building lightning protection (all materials & accessories like Shielding Wire, PG clamp, Test link, D shackle etc) as per IS/National Building code standard

-

-

-

... More
20x3mm copper Flat for horizontal and down conductor

310

-

-

... More
10mm dia 1000mm Long Air Termination Spike

8

-

-

... More
GS Fixing Clamps for 20x3mm Copper Conductor

210

-

-

... More
Test Joint

6

-

-

... More
G.I Cable Trays including support GI angle suitable for different sections along with its accessories as per TS. Details of No. of tiers are indicated in the TS-Civil Section accordingly the requirement can be ascertained & High Quality ISI mark PVC-U selfit Pipe, PVC elbow bend, PVC Tee etc suitable for under ground burrial (Hard Conduit Including of adequate tensile strength minimum 7kg/sqmm or better) as per TS.

-

-

-

... More
G.I Cable Trays(size: 450x75x2500mm)

138

-

-

... More
G.I Cable Trays(size: 300x75x2500mm)

55

-

-

... More
G.I Cable Trays(size: 150x75x2500mm)

65

-

-

... More
Support G. I angle 50x50x6 mm including 6mm MS plate for cable tray

2.6

-

-

... More
100mm dia PVCPipe

30

-

-

... More
50mm dia PVC Pipe

20

-

-

... More
Sub Station Switchyard BMK, AC Console & Other MB as per Tech Spec.

-

-

-

... More
Switchyard AC Console for Lighting

2

-

-

... More
Switchyard Receptacle Board for TFR Oil Filteration (01 no. near 220/33kV Power transformer)

1

-

-

... More
Switchyard Receptacle Board for Welding & Other Emergency Nature Work

1

-

-

... More
33kV switchyard Bay Marshalling Kiosk

2

-

-

... More
Lighting cum Lightning Mast ( Including Foundation bolts) for 220/33kV Class

-

-

-

... More
Fixing of Lighting cum Lightning arrangement including LED lighting fixtures (excluding 30 Meter Monopole) with control gear panel etc suitable for wind zone-V , with all other accessories like motor for hoisting/lowering the lighting platform & other switchgear and lighting control panel etc.

2

-

-

... More
Erection of 30 Mtrs height Monopole (HDG) Lighting cum Lightning Mast structure suitable for wind zone-V

2

-

-

... More
General Equipment & Substation Accessories: Supply of Power and control cable including fixing of cable with terminal connections both at equipments and control panels with supply of and fixing of lugs, Ferrules, clamps, connectors, glands, fixing of cable trays, including supply of N&B, Link plates, Cable Markers, Plaster of Paris, M-Seal Compounds etc., for sealing purposes and all neccessary arrangments, Supply of Earthing Flats, Earthing, laying of Cable trench slabs and chequered plate etc., for the cable trench, Cable scheduled and cable diagram to be prepared by the Contractor.

-

-

-

... More
Power Cables, 1.1kV, XLPE & PVC Armoured, Aluminium Conductor (As per Specification) including power cable termination, Lugs, Glands & other materials in order to complete the activity.

-

-

-

... More
3.5CXI85 mm² XLPE

180

-

-

... More
3.5CX120 mm² XLPE

100

-

-

... More
3.5CX70 mm² PVC

260

-

-

... More
3.5CX35 mm² PVC

300

-

-

... More
4CX 16 mm² PVC

884

-

-

... More
4CX 6 mm2 PVC

300

-

-

... More
2CX 6 mm2 PVC

1569

-

-

... More
Control Cables, 1.1kV, PVC Armoured Stranded Copper (As per specification) including control cable termination, Lugs, Glands & other materials in order to complete the activity.

-

-

-

... More
5CX 2.5 mm2

6078

-

-

... More
10CX 2.5 mm2

1682

-

-

... More
12CX 2.5 mm2

3722

-

-

... More
16CX 2.5 mm2

1180

-

-

... More
19CX 2.5 mm2

2130

-

-

... More
1CX 120 mm2 Bat to Bat Charger & Charger to DCDB

90

-

-

... More
Station Transformer & Other Materials for Meeting the Auxiliary Supply of the Substation As Per Technical Specification

-

-

-

... More
STATION TRANSFORMER 33KV/0.43 KV,250 KVA (AS PER SPECIFICATION)

2

-

-

... More
SUB STATION LIGHTING (AS PER TECHNICAL SPECIFICATION)

-

-

-

... More
Indoor Lighting:

-

-

-

... More
220kV GIS Building Indoor Lighting, it includes fixtures & lamps (LED) of OPTCL approved Make with switchgear, Conduit & other required materials for succesful illumination of the area/rooms. (No. of LED Lighting fixtures are to be calculated based on the illumination design considering the required lux level indicated in the technical spec & fixing of the same rigidly on the suitable height either ceiling & wall as required.) (i) 150W High bay LED of OPTCL approved make

1

-

-

... More
Control room building indoor Lighting, it includes fixtures & lamps (LED) of OPTCL approved make with switch gear, Conduit & other required materials for succesful illumination of the area/rooms.( No. of LED Lighting fixtures are to be calculated based on the illumination design considering the required lux level indicated in the technical spec & fixing of the same rigidly on the suitable height either ceiling & wall as required.) (i) Surface Mounted LED 42W of OPTCL approved make (ii) 34W LED Lights of OPTCL approved make ( for control room) (iii)36W LED Corrossion Proof Luminaire with IP65 Protection suitable for dusty & Corrossive atmosphere of OPTCL approved make for battery room.

1

-

-

... More
Indoor Lighting OF Security Shed cum Visitors room, FFPH Building, Store Shed, Parking shed: It includes fixtures & lamps (LED) of OPTCL approved make with switch gear,Conduit & other required materials for succesful illumination of the area/rooms. (No. of LED Lighting fixtures are to be calculated based on the illumination design considering the required lux level indicated in the technical spec & fixing of the same rigidly on the suitable height either ceiling & wall as required.) (i) 34W LED Lights of OPTCL approved make ( for control room)

1

-

-

... More
Outdoor Lighting:

-

-

-

... More
Sub-Station Switchyard Lighting, it includes fixtures & lamps (LED) of OPTCL approved Make with switchgear, GI Conduit etc.(Lighting fixtures are to be fixed rigidly on the Column at a suitable height so that the required lux can be achieved).(150 watt each)

12

-

-

... More
Street Lighting: GI Tubular Pole: (410-SP-24: IS 2713-Part-II-1980 or latest) Length of pole 8.5 mtrs(minimum weight 158 Kgs). & LED light fittings etc. (All the Street Light Pole Shall be of GI Tubular Pole and provision of a GI Junction box with Suitable Covers at a height of 1 Metre from the Ground. The Junction Box shall have Provision of Fuses, Buses, Connectors for cable in and out. ( It Includes LED Lighting Fixtures with Lamps of 100Watts of OPTCL approved make & as per technical specification).

18

-

-

... More
Outdoor Kiosk for Street Lighting Purpose having 2 Nos. 200Amp Switch Fuse Units and , 6 Nos. outlets of 32Amp MCB For Street Lighting. (Suitable For XLPE Cables (3.5C X 120Sqmm) from Main ACDB from Control Room to the Outdoor Kiosk. XLPE Cable Of 4C X 16Sqmm from Outdoor Kiosk to the Street Light Poles and 4C X 6Sq.mm from Pole to Pole and 2C X 6Sq.mm from Pole to Lighting Fixtures. 1 No. Outdoor Kiosk for Colony Supply Purpose (* Remarks: For Supply of All the Cables As Indicated Are Covered In the Cable Items As Indicated Above)

1

-

-

... More
2 TR Capacity Split Air Conditioning Units (Inverter type latest model) of OPTCL approved make.

12

-

-

... More
220kV GIS hall-ventilation system through ducting (Pressurization type ventilation system) at AHU room as per technical specification

1

-

-

... More
Fire Fighting System (Portable /Trolley/ Wheel Mounted Fire Extinguishers sets for Control Room, Equipment like Transformer and other areas as per Tech Spec.

-

-

-

... More
Foam Type-9 Ltrs

4

-

-

... More
Dry Chemical Powder (Trolley Mounted)- 22.5Kgs

4

-

-

... More
Dry Powder Type - 5Kgs

4

-

-

... More
Co₂- 4.5Kgs

10

-

-

... More
CO₂ - 9Kgs

10

-

-

... More
CO₂ (Trolley Mounted)- 22.5Kgs

4

-

-

... More
Fire Bucket (6 Nos in each stand) with stand

5

-

-

... More
9 litre water type

4

-

-

... More
4.5 kg DCP type

4

-

-

... More
50 Litres Mechanical Foam type

2

-

-

... More
Smoke & Heat detection system: Addressable optical Smoke & Heat Multi detector( 50 Nos) for main control room building including all accessories, Main control panel(Microprocessor based 2 loop fire alarm control panel expandable upto 18 loops fully networkable with each loop capable of taking 99 devices, 8 line x 40 character alpha- numeric liquid crystal display .The panel shall be soft addressable type . The panel shall be able to give pin point location of all fire/fault conditions. Further, the panel must be able to automatically switch off respective control switches when ever any alarm is triggered. The panel shall have in built rectifier, Loop cards,provision for externel & internal printer(if required), L C D unit to indicate Fire/Fault Signal with address and analog output, built in printer to log all fire or fault events complete in all respects, integral SMF lead acid batteries with sealed cells of 24 V capable of running for a minimum of 8 hours with integral battery charger complete as required and as per specification. The fire alarm panel shall be suitable for software integration with BMS & PA system ,wall mounting loop powered addressable type hooter with all accessories , addressable manual call box made of polycarbonate with plastic break glass front and complete with monitor module MCB, addressable isolator module with required PVC box, fittings and fixtures, wiring with PVC FRLS wire to cover the required for fire & smoke detection etc. (One control room building & 1 no. GIS hall are to be provided with Heat & smoke detection). Should have facility for integration with SAS.

1

-

-

... More
Fire Fighting (HVW system & hydrant system) system with Detailed Design Suitable for 20MVA, 220/33kV Power Transformer etc., as per the Latest Standard & TS.

-

-

-

... More
Fire Fighting Equipment: (Main Pump, Jockey Pump, DG Set cum Pump, Control Panel for Fire Fighting System (HIGH PRESSURE : Hydrant and Mulsifire system) to take care of 1 No. 20 MVA, 220/33 KV POWER TRANSFORMER, switcyard equipment and buildings. HVW system & hydrant sytsem, complete with all piping, valves, fittings etc inside pump house for Fire protection sytem of substation) as per the technical spec & Latest standard.

1

-

-

... More
Hydrant pipe for Substation fire protection system

0.08

-

-

... More
Hydrant sytsem, complete U/G piping of different sizes,valves and accessories etc outside the Pump House for Fire protection sytem of 1 Nos. 20 MVA, 220/33 KV POWER TRANSFORMER, switcyard equipment and buildings as per the technical spec & Latest standard.

1

-

-

... More
HVW Spray sytsem, Hydrant System and complete U/G and O/G piping,different type of valves,Fire sensor etc and accessories etc near the Transformer for Fire protection of 1 No. 20 MVA, 220/33 KV POWER TRANSFORMER, as per the technical spec.

1

-

-

... More
Substation Automation System for 220/33kv Substation on Parallel redundacy protocol(PRP) mode: Design, Engineering, Drawing, Supervision, Installation, Testing & Commissioning of Substation Automation System along with Supply of the following 220 And 33kV level of Protection Panels consisting of Bay Control Units & Numerical Protection Relays and other Auxiliary Relays Suitable for SAS as Per Technical Specification. NOTE: All Protective Relays & BCU Shall Be Numerical Type.

-

-

-

... More
Gate way panel for Sub-Station Automation (in PRP as per the specification & indicative drg ) system (for All 220 & 33 KV side bays including the future bays),other accessories (comprising servers, engg. Station, works station (Main & standby), Remote station control, Colour Laser jet Printers & dot matrix printer for local station as per requirement and also for remote station, Ethernet Switches , LIU, Red Box, Multimode glass fibre Doublle jacket armoured optical cables, special cables like F.O patch cord & armoured FO cables of adequate length etc required for the system in all respect as per latest IEC 61850 standard, Inverters of required capacity & rating (Input shall be both A.C & D.C and output shall be A.C) etc as per TS. A large vedio screen of 60 inches for display including all type of accessories & as per technical specification.

1

-

-

... More
BCU for Substation Auxilliary System (Station AC, Station DC, Lighting, Fire fighting, Diesel generator etc. as per the site requirement)

1

-

-

... More
220 KV PROTECTION PANELS

-

-

-

... More
Feeder Protection panel (Main-I , Main-II & Back-up protection with auto reclosure Distance Protection) with Bay control unit (BCU) for substation automation system. (Simplex with front Glass door)

4

-

-

... More
Transformer Protection Panel (Differential I & II , REF I & II & Back-up Protection for HV & LV side Considering HV & LV side of 220/33kV, 20MVA) with Bay control units (BCU) for HV & LV for substation automation system. (Simplex with front Glass door)

1

-

-

... More
Bus Coupler Protection Panel with Bay control unit (BCU) for substation automation system. (Simplex with front Glass door)

1

-

-

... More
Bus-Bar Protection Panel (Provision of bus bar modules for the future bays and to be integrated with the Automation system) (Simplex with front Glass door).

1

-

-

... More
87L (Line differential relay) Numerical Relay for remote End Station

2

-

-

... More
33 KV PROTECTION PANELS

-

-

-

... More
33kV Feeder Protection Panel with Bay control Protection unit (BCPU) for substation automation system

2

-

-

... More
33kV Transformer Protection Panel with Bay control Protection unit (BCPU) for substation automation system (33kV side of 220/33kV, 20MVA)

1

-

-

... More
33kV Transfer Bus Coupler Protection Panel with Bay control Protection unit(BCPU) for substation automation system.

1

-

-

... More
AC & DC SYSTEM

-

-

-

... More
AC SYSTEM

-

-

-

... More
Main ACDB, Facilities for integration with SAS as per the site requirement, as per specification

1

-

-

... More
ACDB as per Technical Specification.

1

-

-

... More
Main Lighting Distribution Board as per Technical Specification

1

-

-

... More
Indoor Lighting Distribution board as per Technical Specification

1

-

-

... More
Emergency Lighting Distribution Board

1

-

-

... More
Indoor Receptacle Board

2

-

-

... More
220V & 48V DC System:

-

-

-

... More
220V DC BOARD (Having 100A DC MCCB as Incomer , E/F (Earth Leakage), Under & Over Voltage as per Specification (DCDB-1,DCDB-2 & B/C). Consider Separate Source (DC1 & DC 2) to each panels & accordingly sufficient Nos. of DC output from DB-1 & 2 to be considered. Facilities for integration with SAS as per the site requirement.

1

-

-

... More
220V DC Emergency Distribution Board

1

-

-

... More
Battery (350AH PLANTE type) for 220V DC

2

-

-

... More
Battery Charger for 350AH, 220V DC (Float & Float cum Boost) (including provision of series dropper diodes with heat sinks & other protection facility at the DC Load terminal end in order to feed 220V to the load).Facilities for integration with SAS as per the site requirement.

2

-

-

... More
DE MINERALISED PLANT of 30 L/Hr for making Distilled water for battery banks

1

-

-

... More
48V DC BOARD (Having 75A DC MCCB as Incomer , E/F (Earth Leakage), Under & Over Voltage as per Specification (DCDB-1,DCDB-2 & B/C). Consider Seprate source (DC1 & DC2)to each panels & accordingly sufficient Nos. of DC output from DB-1 & DB-2 to be considered. Facilities for integration with SAS as per the site requirement.

1

-

-

... More
48V, 300 AH, VRLA type battery set

2

-

-

... More
SMPS based battery charger for 48V, 75A float cum boost (as recommended by the Battery manufacturer)

2

-

-

... More
Accessories for FOTE / OPGW System as per technical specification:

-

-

-

... More
24 Fibre (DWSM) OPGW fibre optic cable

0.1

-

-

... More
OPGW hardware set like suspension assembly, Tension Assembly (Dead end assembly, pass through assembly), vibration damper, down lead assemblies for 24/48 fibre (DWSM) OPGW, Joint box

1

-

-

... More
Optical line terminal equipment (OLTE)-STM4 type SDH equipment with integrated MUX & tributary cards for speech & data ports for interfacing of speech & data which should be compatible with existing OPTCL system.

1

-

-

... More
Supply of FODP (Fibre optic Distribution panel) 48 F: Indoor type, rack mounted with FCPC coupling and pigtails (DWSM fibre)

1

-

-

... More
Digital tele-protection coupler compatible for interfacing with SDHMUX

1

-

-

... More
Earth flat, cable tray, telephone cable, ACDB, DCDB, foundation rail, Junction Box, Cat 5 cable & Misc items

1

-

-

... More
EOT Crane for GIS building for 220kV GIS station (5T Capacity safe working load & minimum height of crane have shall be 8.0 meters or as per actual requirement whichever is higher. The crane shall have minimum speeds under full load of: Speed (a) Hoisting 2 meters/minute (b) Cross Travel 10 meters/minute (c) Long Travel 20 meters/minute (d) Creep speed shall be of 25% of operating speed.The crane shall be possible to be operated through the cable, through the pendant control and which shall be easily accessible from the floor of GIS building and through remote control device. ) including all accessories with control panel.

1

-

-

... More
DIFFERENT TYPE OF LATICE TYPE COLUMNS WITH DETAILS & DIFFERENT TYPE OF BEAMS WITH DETAILS

-

-

-

... More
(Tower) 220kV COLUMN: P1S TYPE,- HEIGHT-21.5 MTRS

14

-

-

... More
(Girder) 220kV BEAM:Q1 TYPE,-LENGTH-18 MTRS

3

-

-

... More
(Tower) 33kV COLUMN, HEIGHT-8 MTRS

9.7

-

-

... More
(Girder) 33kV BEAM:G1 TYPE,-LENGTH-5.5 MTRS

4.15

-

-

... More
SUPPORT STRUCTURES FOR OUDOOR EQUIPMENTS

-

-

-

... More
SUPPORT STRUCTURES FOR 220kV EQUIPMENT

-

-

-

... More
220kV Isolator

7

-

-

... More
220kV Surge Arrester

4

-

-

... More
220kV Current transformer

1.5

-

-

... More
220kV Potential transformer

1.2

-

-

... More
220kV Cable sealing end

1.5

-

-

... More
SF6 Bushing

4.5

-

-

... More
SUPPORT STRUCTURES FOR 33kV EQUIPMENT

-

-

-

... More
33 KV Lightning Arrestor

0.7

-

-

... More
33 KV Current Transformer

1.5

-

-

... More
33 KV Bus Potential Transformer

0.3

-

-

... More
33 KV Metering Current Transformer

0.6

-

-

... More
33 KV Metering VoltageTransformer

0.6

-

-

... More
33 KV Bus Post Insulator

3

-

-

... More
33 KV Horn Gap Fuse

0.64

-

-

... More
33 KV Isolator

2.32

-

-

... More
33 KV Isolator with ES

1.6

-

-

... More
Cable End Termination

0.8

-

-

... More
Gl bolts ,Nuts, washers plain & spring etc for the above structures

2.18

-

-

... More
GI Foundation bolts & nuts with plate & other washers as required

3.95

-

-

... More
Triple Pole Structure for Double circuit 33kV Line: 3 Nos. Galvanized H-Type 14 Mtr. Structure including Channels, Angles and Flat for Belting, Bracing, mounting and termination of 6 Nos. 33kV Single core cable. This also includes supply of Lightning Arrestors, GO AB Switch, Polymer Pin & Disc Insulators incl. Hardware fittings, Complete Stay Ser, Earthing arrangement, HDPE Pipes from Ground Level to a Suitable Height on the Pole etc. to terminate the 33kV Cable on the structure complete. Note: Stringing of 148 Sq.mm. AAA Conductor from this Gantry to TFL Pump House is not included in above.

1

-

-

... More
220kV XLPE Cable Package (220kV GIS station to MRSS station):

-

-

-

... More
220kV XLPE copper Cable 1Cx1000 sq.mm Single Core (from 220kV GIS station side to MRSS Station having each phase one run)

4.45

-

-

... More
24 Fibre (DWSM) OPGW fibre optic cable

1.5

-

-

... More
installation hardware for 24 fibre optic cable

1

-

-

... More
50mm DIA PVC PIPE / 40mm DIA PLB DUCT (OPTICAL FIBER CABLE)

1.5

-

-

... More
220kV XLPE cable straight through joint kit complete suitable for cable with Link boxes

6

-

-

... More
Cross bonding & Link Boxes for Earthing

2

-

-

... More
SCHEDULE-2C-SS (CIVIL-ERECTION)

-

-

-

... More
SOIL INVESTIGATION & SITE LEVELLING

-

-

-

... More
Contour survey of the entire sub-station area including Supply of all labour & T&P

1

-

-

... More
Soil investigation: Supply of labour,T&P and other necessary arrangements for Soil investigation/testing of the complete Substation Area.as per the site requirement,Technical specification & instruction of Engineer-in-Charge

1

-

-

... More
SITE LEVELLING Providing, neatly dressing up and leveling of substation area to a required level as decided by the Engineer in Charge, the work includes removal, clearing of the entire area from vegetation, trees, bushes, uprooting of plants and disposal of surplus earth and unusable material from the site by means of any mechanical transport, if required as per direction of the Project In charge and as per Site Requirement, approved drawing and specification. This also includes excavation in all type of soils or rocks, back filling and disposal of excess earth or rocks to make the area to a level for construction as per scope and as per approved drawing and specification.

-

-

-

... More
Cutting of earth & filling of excavated soil

100

-

-

... More
Filling with borrowed earth beyond 100 mtrs lead

100

-

-

... More
220KV AND 33KV TOWERS AND OUTDOOR EQIIPMENT FOUNDATIONS: Supply & storage of Material/Raw Material i.e. Cement, water, reinforcement steel, coarse and fine aggregates (Sand and Metal Chips etc), Manpower, Tools & Plants, Machinery along with other required material for Design, engineering, and construction of PCC & M25 Design Mix RCC, footings of any depth, pedestal, excavation, concreting, shuttering, grouting, underpinning and back filling of foundations etc complete for switch yard gantry/ portal structures and equipment support & others as per the technical specification and approved drawings. This also includes excavation in all types of soil or rocks, back filling and disposal of excess earth as per the direction of Engineer In charge.

-

-

-

... More
Excavation & Back filling of excavated Soil

2333

-

-

74

-

-

401

-

-

... More
Reinforcement Steel

143

-

-

... More
30 Mtr. Lighting cum Lightning Mast: Supply & storage of Material/Raw Material i.e. Cement, water, reinforcement steel, coarse and fine aggregates (Sand and Metal Chips etc), Manpower, Tools & Plants, Machinery along with other required material for Design, engineering, and construction of PCC & M25 Design Mix RCC, footings of any depth, pedestal, excavation, concreting, shuttering, grouting, underpinning and back filling of foundations etc complete for Lighting cum Lightning Mast as per the technical specification and approved drawings. This also includes excavation in all types of soil or rocks, back filling and disposal of excess earth as per the direction of Engineer In charge.

-

-

-

... More
Excavation & Back filling of excavated Soil

32

-

-

2.88

-

-

12.38

-

-

... More
Reinforcement Steel

0.34

-

-

... More
CABLE TRENCH: Supply & storage of Material/Raw Material i.e. Cement, water, reinforcement steel, coarse and fine aggregates (Sand and Metal Chips etc), Manpower, Tools & Plants, Machinery along with other required material for Design, engineering, and construction of M25 Design Mix RCC cable trenches and all associated works for cable trench and cable trench crossings as per technical specifications and approved drawings and as per direction of the Engineer in Charge. (1) This also includes excavation in all types of soil or rocks,back filling,and disposal of excess earth as per the direction of Engineer In charge. (2) Design, Engineering, Providing and laying of plain cement concrete with approved quality coarse aggregates (Nominal size 12mm to 20mm) , fine aggregates, cement in cable trench as blind layer inclusive of labour charges for concrete mixing & curing. This includes supply of all labourers, T&P and dewatering wherever required as per Technical specification and instruction of Engineer In charge. (3) Open cast foundation for the cable trench with RCC, including supply of Labour all materials like Reinforcement Steel, Cement, coarse and fine aggregates,shuttering,cutting,bending,binding of Reinforcement Steel including supply of binding wire proper curing of the foundations/concrete and T&P in line with the Specification and as per direction of Engineer in Charge. (4) Fly ash Brickwork, plastering & curing, wherever required including the supply of labour,material, cement, etc. (5) Fixing of MS Angle (G.I) for cable tray support (as per specification). The cable tray support frame shall be pre fabricated GI angle as per requirement and to be welded with the plate fixed on the trench wall for better rigidity. The plate (6mm) fixed on the wall are also to be welded with the Reinforcement Steel provided for the trench wall before concreting. (6) Precast of RCC covers and its fixing on the cable trench as per spec and instruction of Engg. In Charge. (7) CABLE TRENCHES INSIDE THE CONTROL ROOM SHALL BE COVERED WITH M.S CHEQUERED PLATE (Duly painted as per instruction of Engg in charge) INCLUDING STANDARD SUPPORT STAND {HD Galvanised (M.S JOIST ,CHANNEL,ANGLE)}..

-

-

-

... More
Section 1-1 (1275MM X 1400MM)

35

-

-

... More
Section 2- 2 (1275MM X900MM)

75

-

-

... More
Section 3-3 (1075MM X900MM)

25

-

-

... More
Section 4-4 (545MM X 250MM)

40

-

-

... More
BURIED CABLE TRENCH: Provision of Buried cable trench for 33kV Power cable, including excavation and backfilling and all relevant civil work as per TS and approved Drawing

135

-

-

... More
RAIN WATER HARVESTING: Rain water harvesting system as per Technical specification and approved drawing

2

-

-

... More
SUBSTATION BUILDINGS:

-

-

-

... More
220KV GIS BUILDING (Approx. Area: Approx. 320 Sq.Mtr. & AHU Room Area: Approx. 34 Sq. Mtr.): Supply & storage of Material/Raw Material i.e. Cement, water, reinforcement steel, coarse and fine aggregates (Sand and Metal Chips etc), Manpower, Tools & Plants, Machinery along with other required material for Design, engineering and construction of M25 Design Mix RCC GIS Building, the cost of material, supply of labour, cement, reinforcement- steel, form work and excavation as per the approved drawing and technical specification. This also includes excavation in all types of soil or rocks, back filling, and disposal of excess earth as per the direction of Engineer In charge. As per approved drawings and specification. The area given is for reference only and may vary according to requirement of the equipment to be installed inside. The contractor shall finalize the dimensions according to the equipment offered by them providing enough space & access for erection, operation and maintenance & future expansion.

-

-

-

... More
RCC volume including Reinforcement Steel (including column ,Beams and roofs etc) as per technical spec & approved drawings.

1

-

-

... More
Fly ash Brick masonry by using fly ash Brick work in cement sand mortar with Bricks of class designation 75 as per technical spec & approved drawings.

1

-

-

... More
Flooring of GIS room shall be epoxy paint of adequate thickness & Flooring adjacent panel rooms shall be with vitrified digital tiles with dado as per technical spec & approved drawings.

1

-

-

... More
External and internal wall (External (18mm thk) and internal (12 mm thk) wall and ceiling plastering as per technical spec mentioned in the civil section & approved drawings.

1

-

-

... More
Provision of ceiling in the adjacent panel room area as per specification mentioned in the civil section & approved drawings.

1

-

-

... More
Doors and windows shall be of sliding type with locking facility and shall be of aluminium with glaze of 6mm & windows shall have aluminium grills. As per technical spec & approved drawing.

1

-

-

... More
Internal concealed wiring (including flexible copper FRP 1.1 KV PVC wire,conduits & its accessories,modular type switches & switch board, Junction boxes with required MCB & Earth leakage detector switcghear etc, fixing of lighting fixtures & switchgear , Erection of all Lighting FIXTURES & LAMPS (LED), D.C emergency lighting (including supply),cabling for EOT crane including supply and installation of Switch Board panel required for EOT crane as per approved drawing and direction of Engineer In charge.

1

-

-

... More
Provision of smoke and fire detection & Alarm system of the building.

1

-

-

... More
Provision of rails & other arrangement including all type of Civil works for EOT crane. This is as per the standard practice adopted in GIS sub-station and as directed by the Engineer in Charge.

1

-

-

... More
Provision of rain water discharge pipes at different locations and etc as per requirement and approved drawing. It includes supply of all types of materials of reputed make, labour etc to complete the work.

1

-

-

... More
External and internal wall painting with primer coat as per technical spec mentioned in the civil section. External: One coat weather coat primer + two coats of weather coat colour paint. Internal: Two coats wall putty+solvent thinable white primer of one coat+two coats colour paint. As per Technical Specification.

1

-

-

... More
Installation of Ventilation system of all equipment and materials as per technical specification (design calculation to be submitted)

1

-

-

... More
CONTROL ROOM BUILDING (Area: Approx. 382 Sq.Mtr.): Supply & storage of Material/Raw Material i.e. Cement, water, reinforcement steel, coarse and fine aggregates (Sand and Metal Chips etc), Manpower, Tools & Plants, Machinery along with other required material for Design, engineering and construction of M25 Design Mix RCC Control Room Building, the cost of material, supply of labour, cement, reinforcement- steel, form work and excavation as per the approved drawing and technical specification. This also includes excavation in all types of soil or rocks,back filling,and disposal of excess earth as per the direction of Engineer In charge. As per approved drawings and specification. The area given is for reference only and may vary according to requirement of the equipment to be installed inside. The contractor shall finalize the dimensions according to the equipment offered by them providing enough space & access for erection, operation and maintenance & future expansion.

-

-

-

... More
RCC volume including Reinforcement Steel (including column ,Beams and roofs etc) as per technical spec & approved drawings.

1

-

-

... More
Fly ash Brick masonry by using fly ash Fly ash Brick work in cement sand mortar with Fly ash Bricks of class designation 75 as per technical spec & approved drawings.

1

-

-

... More
Flooring with double charged vitrified digital tiles with dado in all the rooms, Bath and toilets shall be provided with anti skid ceramic digital tiles (wall of the same also to be provided with ceramic digital tiles), Acid proof industrial tiles to be provided on the floor and full wall of the battery room as per technical spec & approved drawings. Stair case & its landing platforms are to be provided with Granite flooring.

1

-

-

... More
External and internal wall (External 18mm thk and internal 12 mm thk) wall ceiling plastering as per technical spec mentioned in the civil section and Building internal & external & ceiling paintings as per technical spec mentioned in the civil section. The ceiling of Battery room shall be acid proof paints as per specification & approved drawings.

1

-

-

... More
Provision of ceiling in the control room area as per specification mentioned in the civil section & approved drawings.

1

-

-

... More
Doors and windows shall be of sliding type with locking facility and shall be of aluminium with glaze of 6 mm & windows shall have aluminium grills. As per technical spec & approved drawing.

1

-

-

... More
Internal concealed wiring (including flexible copper FRP 1.1 KV PVC wire,conduits & its accessories,modular type switches & switch board,Junction boxes with required MCB & Earth leakage detector switcghear etc),fixing of lighting fixtures & switchgear ,ceiling fans of 1400 sweep and regulators( including supply) ,exhaust fan (including supply), Erection of all Lighting FIXTURES & LAMPS (LED), D.C emergency lighting (including supply), as per approved drawing and direction of Engineer In charge.

1

-

-

... More
Installation of smoke and fire detection & Alarm system of the building.

1

-

-

... More
Supply, fitting and fixing of stainless steel pf 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with balustrade of size 32mmx32mmx32mm @0.90mtr C/C and stainless square pipe bracing of size 32mmx32mmx32mm in three rows in staircase as per approved design and specification, buffing,polishing etc with cost, conveyance, taxes of all materials, labour, T&P etc required for the complete in all respect

1

-

-

... More
External and internal wall painting with primer coat as per technical spec mentioned in the civil section. External: One coat weather coat primer + two coats of weather coat colour paint. Internal: Two coats wall putty+solvent thinable white primer of one coat+two coats colour paint. Refer the specification.

1

-

-

... More
Provision of PHD and other fittings(in Toilets,wash room,overhead water tank of adequate capacity etc) of reputed make,provision of rain water discharge pipes at different locations and etc as per requirement and approved drawing. There shall be septic tank and soak pit of required capacity including complete sewage system as per approved drawing & technical specification & as per instruction of Engg- in-Charge. It includes supply of all types of materials of reputed make, labour etc to complete the work. Toilets for Gents & Ladies to be provided including all good quality reputed fittings as per technoical specification. The toilets & wash room shall have antiskid floor tiles & wall tiles of seramic upto height of 8 feet.

1

-

-

... More
SECURITY SHED & CUM VISITOR ROOM (Approx. Area: 17.5 Sq.Mtr.) : Supply & storage of Material/Raw Material i.e. Cement, water, reinforcement steel, coarse and fine aggregates (Sand and Metal Chips etc), Manpower, Tools & Plants, Machinery along with other required material for Design, engineering and construction of M25 Design Mix RCC Security Shed, the cost of material, supply of labour, cement, reinforcement- steel, form work and excavation as per the approved drawing and technical specification. This also includes excavation in all types of soil or rocks,back filling,and disposal of excess earth as per the direction of Engineer In charge. As per approved drawings and specification. The area given is for reference only and may vary according to requirement of the equipment to be installed inside. The contractor shall finalize the dimensions according to the equipment offered by them providing enough space & access for erection, operation and maintenance & future expansion. The height of the building shall be of 3.5mtrs RCC roof, Fly ash Brick masonary works, plastering and painting and fixing of MS doors and windows. Internal concealed wiring (including supply of flexible copper FRP 1.1 KV PVC wire,conduits & its accessories,modular type switches & switch board, Junction boxes with required MCB & Earth leakage detector switcghear etc), fixing of lighting fixtures & switchgear, ceiling fans of 1400 sweep and regulators (including supply) and provision of incoming AC supply from the main ACDB/outdoor kiosks installed for street light. Also includes painting of the building (in side and out side) as per recommended for colony building in the specification.

1

-

-

... More
STORE SHED (Area: Approx. 100 Sq.Mtr.): Supply & storage of Material/Raw Material i.e. Cement, water, reinforcement steel, coarse and fine aggregates (Sand and Metal Chips etc), Manpower, Tools & Plants, Machinery along with other required material for Design, engineering and construction of M25 Design Mix RCC Store Shed, the cost of material, supply of labour, cement, reinforcement- steel, form work and excavation as per the approved drawing and technical specification. This also includes excavation in all types of soil or rocks,back filling,and disposal of excess earth as per the direction of Engineer In charge. As per approved drawings and specification. The area given is for reference only and may vary according to requirement of the equipment to be installed inside. The contractor shall finalize the dimensions according to the equipment offered by them providing enough space & access for erection, operation and maintenance & future expansion. One no store shed of Approx. floor size of 10X10 mtr having Fly ash Brick walls and plastering with RCC roof. The flooring shall be of 75 mm thickness PCC over RR masonry works (as per standard practice of flooring). Provision of adequate nos of MS racks (proper paintings also to be done as per the direction of site in charge) for keeping the spare materials. The height of the shed shall be 4mtrs above the plinth. Internal concealed wiring (including supply of flexible copper FRP 1.1 KV PVC wire,conduits & its accessories, modular type switches & switch board, Junction boxes with required MCB & Earth leakage detector switcghear etc), fixing of lighting fixtures & switchgear, ceiling fans of 1400 sweep and regulators (including supply) and provision of incoming AC supply from the main ACDB/outdoor kiosks installed for street light. Also includes painting of the building (in side and out side) as per recommended for colony building in the specification.

1

-

-

... More
VEHICLE PARKING SHED: Supply & storage of Material/Raw Material i.e. Cement, water, reinforcement steel, coarse and fine aggregates (Sand and Metal Chips etc), Manpower, Tools & Plants, Machinery along with other required material for Design, engineering and construction of M25 Design Mix RCC Vehicle Parking Shed. This also includes excavation in all types of soil or rocks,back filling,and disposal of excess earth as per the direction of Engineer In charge. The size of the parking area shall be 15mtrs X 15 mtrs, out of the entire area there shall be provision of shed for 5 mtrs X 15 mtrs and rest of the area shall be without shed. 100 mm thick PCC flooring after the preparing the foundation base & Roof of the parking place shall be RCC & Parking shed shall be as per TS & as per the direction of Engineer in Charge.

1

-

-

... More
FIRE FIGHTING PUMP HOUSE BUILDING & ASSOCIATED RCC WATER TANKS: (Approx. Area of the FFPH Building: 50 Sq. Mtr.): Supply & storage of Material/Raw Material i.e. Cement, water, reinforcement steel, coarse and fine aggregates (Sand and Metal Chips etc), Manpower, Tools & Plants, Machinery along with other required material for Design, engineering and construction of M25 Design Mix FFPH building and allied Water Storage Tanks. This also includes excavation in all types of soil or rocks, backfilling and disposal of excess earth as per the direction of Enginer In charge. As per approved drawings and specification.

-

-

-

... More
RCC volume including Reinforcement Steel (including column ,Beams and roofs etc) as per technical spec & approved drawings.

1

-

-

... More
Brick masonry work in cement sand mortar with bricks of class designation 75kg/mm2 as per technical spec & approved drawings.

1

-

-

... More
Concrete Flooring to be provided as per technical spec & approved drawings.

1

-

-

... More
External and internal wall painting with primer coat as per technical spec mentioned in the civil section. External: One coat weather coat primer + two coats of weather coat colour paint. Internal: Two coats wall putty+solvent thinable white primer of one coat+two coats colour paint. Refer the specification.

1

-

-

... More
Doors and windows shall be of sliding type with locking facility and shall be of aluminium with glaze of 6mm & windows shall have aluminium grills. As per technical spec & approved drawing.

1

-

-

... More
Provision of PHD and other fittings of reputed make having ISI mark ,provision of rain water discharge pipes at different locations and etc as per requirement and approved drawing & technical specification & as per instruction of Engg- in-Charge. It includes supply of all types of materials of reputed make, labour etc to complete the work.

1

-

-

... More
Internal concealed wiring,fixing of lighting fixtures(LED) ,fans and regulators(Electronic regulator) ,exhaust fan,D.C emergency lighting INCLUDING SUPPLY OF ALL ITEMS as per spec & approved drawing.

1

-

-

... More
Provision of smoke and fire detection system of the building.

1

-

-

... More
Provision of Water Tank for fire fighting as per TS and approved Drawings

1

-

-

... More
External, internal, ceiling Plastering of Fire fighting as per approved drawing

1

-

-

... More
BOUNDARY WALL: Supply & storage of Material/Raw Material i.e. Cement, water, reinforcement steel, coarse and fine aggregates (Sand and Metal Chips etc), Manpower, Tools & Plants, Machinery along with other required material for Design, engineering and construction of Boundary Wall. The boundary wall shall be constructed to a height of 2 mtrs above finished ground level of the substation area with 10'' wide brick masonry work with M25 Design Mix RCC ground tie beam to be rested on the RCC pillars (pillar to pillar distance @ 3mtrs). Supply & Fixing of Galvanised barbed wire (12 SWG) of 3-rows each on limb of Y shaped frame (Total 6 nos) fencing shall be provided on top of the boundary wall to a height of 0.5 mtr. This also includes excavation in all types of soil or rocks, backfilling and disposal of excess earth as per the direction of Enginer In charge.

405

-

-

... More
ROADS: Supply & storage of Material/Raw Material i.e. Cement, water, reinforcement steel, coarse and fine aggregates (Sand and Metal Chips etc), Manpower, Tools & Plants, Machinery along with other required material for Design, engineering and construction of roads and walkways/ shoulders within sub-station (Switch yard area, approach road, control room building area, main gate to the switch yard gate etc) as per specification, layout and approved drawings complete. This also includes excavation in all types of soil or rocks,back filling,and disposal of excess earth as per the direction of Engineer In charge. Provision of drains on both the side of the roads for easy discharge of rain water.

-

-

-

... More
7.0 mtrs wide Main RCC road with kerb stones at both the side as per technical specification indicated in the civil section (from the switch yard main gate to power transformer, approach road & infront of GIS and control room building & Shall have drain on both side of the road.

200

-

-

... More
3.75 mtrs wide Peripheral RCC with shoulder at both the side & shall have drain on both side of the road as per technical specification indicated in the civil section (Periphery roads outside switch yard fencing)

30

-

-

... More
7.0 Mtrs wide Bitminous Road with shoulder & kerb stones at both sides from nearest Approach Road to the Main Gate of the Switchyard

1

-

-

... More
DRAINAGE SYSTEM: Supply & storage of Material/Raw Material i.e. Cement, water, reinforcement steel, coarse and fine aggregates (Sand and Metal Chips etc), Manpower, Tools & Plants, Machinery along with other required material for Design, engineering and construction of storm water drainage scheme (RCC type), road-culverts as per specification and approved drawing. This also includes excavation in all types of soil or rocks,back filling,and disposal of excess earth as per the direction of Engineer In charge. All the switch yard bays , roads water drainage shall be connected to the main surface drain. As per approved drawing and specification.

-

-

-

... More
Storm water drain (RCC type)

460

-

-

... More
Road-culverts, drain crossings (RCC type) pipe

1

-

-

... More
Cable Trench Crossing

1

-

-

... More
220/33kV POWER TRANSFORMER FOUNDATION-1No Design, engineering, supply of labour, material, equipments for construction of Transformer foundation, all associated works, rail tracks, jacking pads,anchor block RCC and PCC, miscellaneous structural steel including oil collection pits, MS grating (if required), gravel filling, and other items etc. not mentioned herein, but specifically required for the completion of the work as per technical specification and approved drawing. (Rate shall be inclusive of cement, reinforcement steel, angles,flats and form work etc.). Transformer RCC foundation and Rail Track should be extended upto the approaching road (However,the height of RCC foundation beyond transformer main plinth area should be same as height of concrete road). This also includes excavation in all types of soil or rocks,back filling,and disposal of excess earth as per the direction of Engineer In charge.

-

-

-

... More
The rails shall be first quality 52 kg/m medium manganese steel as per Indian Railway specification T-12-64 and its subsequent revision, joined together by fish plates as per Indian Railway specification T-1/57, and 27 mm diameter fish bolts.

30

-

-

... More
Excavation & Back filling of excavated Soil

80

-

-

7.5

-

-

35

-

-

... More
Reinforcement Steel

3

-

-

... More
Other Supply & erection of material in order to complete the Power transformer foundation

1

-

-

... More
OIL SUMP PIT-1 No Design, engineering, supply of labour, material, equipments for construction of Oil collection (from transformers) sump pit with provision of pump (5 HP, with auto level control , including cabling, fixing of control gear ) & pump house over the oil sump pit (as per CIGRE standard) for the oil collection pit inorder to separate oil from the water. Other piping arrangement shall be provisioned to remove water from the oil sump pit. Oil capacity of power transformer in ltrs appox. 20 MVA 220/33KV: 50000 ltrs.

-

-

-

... More
Excavation

62

-

-

0.9

-

-

17.81

-

-

... More
Reinforcement Steel

0.8

-

-

... More
Other Supply & erection of material in order to complete the Oil Sump pit

1

-

-

... More
PCC BEFORE SITE SURFACING: Design, engineering, supply of labour, material, equipments for Leveling of earth after erection of structures and equipments and proper compaction by using roller of adequate capacity (minimum 3 Ton capacity) with water sprinkling of switch yard area. After proper leveling of the switch yard area (after anti-weed treatment), spreading of plain cement concrete using 20 mm nominal metal over a layer of good quality river sand of 25 mm and maintaining proper sloping for easy discharge of storm water having concrete thickness of 75 mm. including rolling, dressing, compacting the area.

310

-

-

... More
METAL SPREADING: Providing supplying and laying two layers of machine crushed metals (gravel) fill, the first layer after compaction shall make minimum 50 mm thickness coarse/ layer of 20 mm nominal size consolidated/ compacted and (by using roller as specified in the specification).A final layer of 50 mm thickness of machine crushed 20 mm nominal size of metals (gravel) above the first layer of 50 mm thickness above the PCC. The total compacted thickness of the metals (20 mm Nominal) 100mm above the PCC.

413

-

-

... More
PROVISION OF GARDEN: Provision of gardens as per approved Drawing including supply and planting of decorative plants, garden grass, flowering plants, soil treatment. Provision of water tap with water sprinkler arrangement including water pipe laying with control at different location. Both side of the RCC roads shall be provided with decorative plants as per approved drawing.

1

-

-

... More
STONE PITCHING & TOE WALL: Stone pitching including making of toe walls both at top and bottom, including surface drain both at top and bottom and partition wall in every 10 mtrs by using boulders and RR masonry walls respectively. This also includes excavation in all types of soil or rocks,back filling,and disposal of excess earth and supply of materials and labour as per the direction of Engineer In charge and as per approved drawing and specification.

-

-

-

... More
Excavation of Soil

1

-

-

... More
P.C.C (1:3:6): Lean Concrete Grade M-10 (Below RR)

1

-

-

... More
RR Masonry (1:5)

1

-

-

... More
P.C.C (1:2:4): Lean Concrete Grade M-15 (above RR)

1

-

-

... More
SWITCHYARD FENCING: Supply and fixing of G.I coat mesh (2.5mm dia) in a (G.I angle 50 X 50 X 6 mm frame having 50 X 6 mm G.I flat bracing corner to corner) fencing (the post and link shall be of HD galvanized) in switchyard and other area of the substation with total fence height complete as per specification and approval drawing and as required under the safety regulation of local, state and central government bodies. This also includes PCC work for grouting the Post and a continuous fly ash brick masonry work and cement point of the joint for the fence upto a height from FGL.

360

-

-

... More
2 x 250KVA STATION TRANSFORMER FOUNDATION: Design, engineering, procurement of labour, material including all associated works for construction of foundation for station transformers as per approved drawing and specification.{other accessories & materials as required need to be supplied for complete installation of transformer as per standard) and instruction of Engineer In charge. As per the specification and approved drawing.

-

-

-

... More
Excavation & Back filling of excavated Soil

35

-

-

0.7

-

-

5.3

-

-

... More
Reinforcement Steel

7

-

-

... More
MAIN GATE & SWITCH YARD GATES: Design, engineering, procurement of labour, material including all associated works for construction and fixing of main gate and switch yard gates as per specification and approved drawing. This also includes excavation in all types of soil or rocks, back filling, and disposal of excess earth as per the direction of Engineer In charge. Provision of gate lights (Post top lantern type) on each pillar of the gate. It includes supply & fixing of light fixtures including LED Gate lamp, LV XLPE cables, switchgear etc required to complete works as per specification and approved drawings

-

-

-

... More
6m Wide Boundary wall Main gate

1

-

-

... More
1.5m Wide Boundary wall Wicket gate

1

-

-

... More
5m Wide Swithyard Fence Gate

2

-

-

... More
BOREWELL: Including supply, fixing and commissioning of 1 Nos. 3 HP submersible water pump with starter and other protection.

1

-

-

... More
COLOUR CODING AND BAY MARKING: Design, engineering, procurement of labour, material including all associated works for the followings. This should be as per direction of site In charge a) Color coding (red,Yellow & Blue) for equipments, Bus gantry & column of entire switch yard. Good quality weather proof sticker may be used for identification. b) Each bay should be identified with the help of bay marker sign board, suitably grouted. MS sign board with stand to be installed. Proper painting and lettering to be done of the entire switch yard area.

1

-

-

... More
ANTI WEED TREATMENT: Supply of labour,T&P,Chemicals and other necessary arrangements for anti-weed treat of the switch-yard areas, control room etc.as per the instruction of Engineer-in-Charge.The chemical to be sprayed as per the standard practice adopted for antiweed treatment of sub-station area & as per the technical specification.

3100

-

-

... More
WATER PIPING: Provision of water discharge (PVC) pipe from borewell pump house to different location and etc as per requirement and approved drawing it also includes supply of all type of materials of reputed make

140

-

-

... More
250KVA DG SET FOUNDATION:

-

-

-

1.3

-

-

23

-

-

... More
Reinforcement Steel

2.8

-

-

... More
220 kVCable package, 1CX 1000 sq mm cable( GIS Station to MRSS Station):

-

-

-

... More
Cable Trench excavation and backfilling of all types of soil (750 meter Long and 2m deep from GIS Station to MRSS Station).

2550

-

-

... More
River Sand filling of 300 mm depth on buried area

450

-

-

... More
Remaining sand filling area to fillup the Trench upto 1.4 depth on buried area

2100

-

-

... More
Cable protection RCC COVER 650X450 on buried area

50

-

-

... More
1 Nos. Cable Jointing chamber (Approx. Size 12000 x 3000 x 2500 mm) with cover

-

-

-

... More
Excavation & Back filling of excavated Soil

100

-

-

2.25

-

-

35

-

-

... More
Reinforcement Steel

1.75

-

-

... More
SCHEDULE 2A-SUPPLY (FOR TRANSMISSION LINE)

-

-

-

... More
SUPPLY of Following type tested Lattice type Galvanized steel tangent / Angle tower with stubs and cleats , different type of G.I HT Nuts & Bolts, washer, spring washer for the towers ,hanger and all accessories, tower super structure complete including step bolts. Supply of black bituminous paint for three coats up to a height of 500mm above the cooping(legs & bracing members). All Supply should confirm to the Technical Specification.

-

-

-

... More
OA TYPE (SUSPENSION) TOWERS (NOMINAL UNIT WEIGHT 4.35 MT)

-

-

-

... More
+3 EXTENSION (NOMINAL UNIT WEIGHT 0.725MT)

-

-

-

... More
+6 EXTENSION (NOMINAL UNIT WEIGHT 1.448 MT)

-

-

-

... More
OB TYPE (30 deg ANGLE ) TOWERS (NOMINAL UNIT WEIGHT 6.575 MT)

-

-

-

... More
+6 EXTENSION (NOMINAL UNIT WEIGHT 2.132 MT)

-

-

-

... More
OC TYPE (60 deg ANGLE ) TOWERS (NOMINAL UNIT WEIGHT 9.8398MT)

-

-

-

... More
+3 EXTENSION (NOMINAL UNIT WEIGHT 1.474MT)

-

-

-

... More
+6 EXTENSION (NOMINAL UNIT WEIGHT 2.597 MT)

-

-

-

... More
+15 EXTENSION (NOMINAL UNIT WEIGHT 8.555 MT)

-

-

-

... More
TEMPLATES

-

-

-

... More
OA (NOMINAL UNIT WEIGHT 0.579 MT)

-

-

-

... More
OB (NOMINAL UNIT WEIGHT 0.815 MT)

-

-

-

... More
OC (NOMINAL UNIT WEIGHT 0.984 MT)

-

-

-

... More
WEIGHT OF THE STRUCTURES & Tempates including Tower Stub

188.05

-

-

... More
Weight of different type G.I Nuts and Bolts

9.4

-

-

... More
Supply of the following tower accessories as per technical specification and as directed by the engineer in charge.

-

-

-

... More
EARTHING DEVICE

18

-

-

... More
DANGER BOARD

18

-

-

... More
NUMBER PLATE

18

-

-

... More
PHASE PLATE

108

-

-

... More
BIRD GUARD

36

-

-

... More
ANTICLIMBING DEVICE

18

-

-

... More
CIRCUIT PLATE

36

-

-

... More
COUNTERPOISE EARTHING

6

-

-

... More
Supply of following POWER CONDUCTORS in the proposed 220kV lines including provision for sag and wastage as per the technical specification and as per the instruction of the engineer in charge.

-

-

-

... More
ACSR Zebra (54/7/3.18mm)

27.3

-

-

... More
POWER CONDUCTOR ACESSORIES For ACSR ZEBRA

-

-

-

... More
VIBRATION DAMPER

216

-

-

... More
MID SPAN JOINT

5

-

-

... More
Repair Sleeve

5

-

-

... More
Supply of the following Anti Fog Type DISC insulators as per the technical specification and as per the instruction of the Engineer in charge.

-

-

-

... More
220kV LONG ROD 160KN PORCILAIN INSULATOR (2 NOS IN 1 SET)

288

-

-

... More
220 KV LONG ROD 90KN PORCILAIN INSULATOR

48

-

-

... More
Supply of the following hard ware fittings suitable for following conductors as per the technical specification.

-

-

-

... More
For ACSR ZEBRA

-

-

-

... More
Single suspension Hard Wares fittings suitable for 90 KN Long ROD Insulator

24

-

-

... More
Double suspension Hard Wares fittings suitable for 90 KN Long ROD Insulator

12

-

-

... More
Single tension Hard Wares fittings, suitable for 160 KN Long ROD Insulator

24

-

-

... More
Double tension Hard Wares fittings, suitable for 160 KN Long ROD Insulator

132

-

-

... More
“D” Shackle

144

-

-

... More
Hanger

36

-

-

... More
U'-Bolt.

36

-

-

... More
OPGW fibre Optic Cable & Hardwares

-

-

-

... More
24 Fibre(DWSM) OPGW fibre Optic Cable

4.5

-

-

... More
OPGW hardware set like suspension Asembly,Tensin Assembly(Dead end assembly, Pass through assembly) ,Vibration Damper,Down Lead Clamp Assembliesfor 24 Fibre(DWSM) OPGW,Joint Box

4.5

-

-

... More
SCHEDULE-2C-ERECTION & CIVILWORKS (FOR TRANSMISSION LINE)

-

-

-

... More
ELECTRICAL WORKS

-

-

-

... More
ERECTION,TESTING & COMMISSIONING of Following tested Lattice type Galvanized steel tangent / Angle tower without stubs and cleats including different type of G.I HT Nuts & Bolts, washer, spring washer for the above type towers ,hanger and all accessories, tower super structure complete with tightening, punching of bolts including step bolts. All other left out portion of the bolts above bottom cross arm shall be riveted by using suitable hammer. Painting of black bituminous paints three coats shall be provided up to a height of 500mm above the cooping legs & bracing members. All Erection should confirm to the Technical Specification laid there in the Tender Specification.

-

-

-

... More
OA TYPE (SUSPENSION) TOWERS (NOMINAL UNIT WEIGHT 4.35 MT)

-

-

-

... More
+3 EXTENSION (NOMINAL UNIT WEIGHT 0.725MT)

-

-

-

... More
+6 EXTENSION (NOMINAL UNIT WEIGHT 1.448 MT)

-

-

-

... More
OB TYPE (30 deg ANGLE ) TOWERS (NOMINAL UNIT WEIGHT 6.575 MT)

-

-

-

... More
+6 EXTENSION (NOMINAL UNIT WEIGHT 2.132 MT)

-

-

-

... More
OC TYPE (60 deg ANGLE ) TOWERS (NOMINAL UNIT WEIGHT 9.8398MT)

-

-

-

... More
+3 EXTENSION (NOMINAL UNIT WEIGHT 1.474MT)

-

-

-

... More
+6 EXTENSION (NOMINAL UNIT WEIGHT 2.597 MT)

-

-

-

... More
+15 EXTENSION (NOMINAL UNIT WEIGHT 8.555 MT)

-

-

-

... More
WEIGHT OF THE STRUCTURES (including Tower stubs, Templates & Foundation Nut and Bolts)

188.05

-

-

... More
Weight of different type G.I Nuts and Bolts

9.4

-

-

... More
Fixing of of Templates & setting of stubs

-

-

-

... More
OA Type

4.96

-

-

... More
OB Type

3.75

-

-

... More
OC Type

15.87

-

-

... More
Erection of following tower accessories as per technical specification and as directed by the engneer-in-charge

-

-

-

... More
EARTHING DEVICE

18

-

-

... More
DANGER BOARD

18

-

-

... More
NUMBER PLATE

18

-

-

... More
PHASE PLATE

108

-

-

... More
BIRD GUARD

36

-

-

... More
ANTICLIMBING DEVICE

18

-

-

... More
CIRCUIT PLATE

36

-

-

... More
Hoisting and fixing of insulators with required accessories, paying out of conductor ,jointing, stringing, sagging & Jumpering etc. of power conductor with G.I. Earth wire in the proposed lines and without earth wire with all required accessories including scaffolding for 33 KV,11 KV, LT , P&T lines, roads and using own required T&P and compression jointing machines etc. with 1.5% provision for Sag & Wastage and as per the direction of Engineer in charge.

-

-

-

... More
STRINGING OF DOUBLE CIRCUIT CONDUCTOR (ACSR ZEBRA, SIX POWER CONDCTOR )

4.48

-

-

... More
ERECTION OF POWER CONDUCTOR ACESSORIES

-

-

-

... More
For ACSR ZEBRA

-

-

-

... More
VIBRATION DAMPER

216

-

-

... More
MID SPAN JOINT

5

-

-

... More
Repair Sleeve

5

-

-

... More
Erection of the following Anti Fog Type DISC insulators as per the technical specification and as per the instruction of the Engineer in charge.

-

-

-

... More
220 KV LONG ROD 160 KN SILICON COMPOSITE INSULATOR

288

-

-

... More
90 KV LONG ROD 160 KN SILICON COMPOSITE INSULATOR

48

-

-

... More
Erection of the following hard ware fittings suitable for following conductors as per the technical specification.

-

-

-

... More
For ACSR ZEBRA

-

-

-

... More
Single suspension Hard wares fittings.(AGS type) suitable for 120 KN insulator.

24

-

-

... More
Double suspension Hard wares fittings.(AGS type) suitable for 120 KN insulator.

12

-

-

... More
Single tension Hard wares fittings, suitable for 160 KN insulator.

24

-

-

... More
Double tension Hard wares fittings, suitable for 160 KN insulator.

132

-

-

... More
“D” Shackle

144

-

-

... More
Hanger

36

-

-

... More
U'-Bolt.

36

-

-

... More
Erection of OPGW cables & hardware sets

4.5

-

-

... More
CIVIL WORKS

-

-

-

... More
SURVEY OF LINE & PREPARATION LAND SCHEDULE: Supply of required T&P’s, Technical personnel’s, labours for conducting

-

-

-

... More
Check survey including supply of all labour, T&P as per instruction of Engineer in Charge and as per the approved profile.

4.48

-

-

... More
Soil Testing in complete shape along with submission of report etc. up to the depth of 15 Mtrs.

18

-

-

... More
EXCAVATION WORKS FOR OPEN CAST/SHALLOW TYPE FOUNDATIONS

-

-

-

... More
Excavation for all type of soil and rocks and back filling (back filling shall be done in layers of 500mm sprinkling of water and compaction thereafter and disposed of excess quantity of excavated soil at suitable place after back filling), & if required for filling the foundation, borrowed earth/morrum/sand shall be brought for filling and compaction, including supply of sand, all T&P, labour as required.

3220

-

-

... More
FOUNDATION MATERIALS: Supply of all materials like cement, steel, all coarse aggregates, fine aggregates and making foundations of the required above mentioned type towers as per the direction laid down in the technical specification and the direction of the site- in charge

-

-

-

... More
Design, Engineering, Providing and laying of plain cement concrete (PCC 1:3:6) of grade M10 with approved quality coarse aggregates (Nominal size 12mm to 20mm) , fine aggregates, cement in tower foundation as blind layer inclusive of labour charges for concrete mixing & curing. This includes supply of all labourers, T&P and dewatering wherever required as per Technical specification and instruction of Engineer In charge.

50

-

-

... More
Design, Engineering and laying of reinforced cement concrete (RCC M25 Design Mix) for open cast foundation with supply of approved quality coarse aggregates(Nominal size 12mm to 20mm), fine aggregates, cement and steel of different size(as per design) with cutting, bending, binding of M.S.Rod (FE-500) including supply of binding wire in tower foundation and inclusive of labour charges for concrete mixing, supply and fixing of form boxes, curing, shoring, shuttering, testing of sample cement concrete cubes as per IS. The height of the coping shall be 350mm above the finished concrete level. The surrounding area shall be clear from materials. Damage of land if any by the contractor shall be repaired before measurement. This includes supply of all labourers, T&P and dewatering wherever required as per Technical specification and instruction of Engineer In charge.

520

-

-

... More
Cutting bending hooking ,fixing and binding in poisition of MS bars for rainforcement of foundation concrete of towers including supply of wire for binding (With supply of steel rod(TATA/RINL/SAIL Make).

33

-

-

... More
Supply of borrowed earth/morrum for back filling for foundation/revertment works

-

-

-

... More
Beyond 30 mtr lead

200

-

-

... More
SHORING & SHUTTERING-Required in wet/submerged or special locations of open cast/shallow type foundations with supply of all materials,T&P and Labour.

500

-

-

... More
WELDING OF TOWER MEMBERS

-

-

-

... More
Supply of all materials for continuous welding of bolts & nuts (around the bolts) up to top of tower without cross arm, including welding rods, welding generator machine (diesel engine operator.), application of required zinc rich paints around the welding portion after welding (two coats),fuel,lubricants,T&P and labours and other arrangements etc.

32028

-

-

... More
REVETMENT: (including Benching) Supply of all materials like cement, Late-rite stone (stone masonry) all type aggregates, labours, & T&P for construction of revetment walls as per requirement to protect the towers, where felt unsafe and as per approved drawing and the direction of Engineer in charge.

-

-

-

... More
Excavation in all type of soil including rock & back filling including supply of sand with back filling.

890.4

-

-

... More
Lean Concrete in the ratio 1:3:6 (Grade M-10) including supply of sand chips etc.

116.14

-

-

... More
PCC in the ratio 1:2:4 (Grade M-15) as above.

15.78

-

-

... More
RR Massonary work in the ratio 1:5.

979.18

-

-

... More
Liaisoning Charges

4.84

-

-

... More
MANDATORY SPARES REQUIRED FOR 220/33KV TFL GIS SUBSTATION AT ANGUL, ODISHA]

-

-

-

... More
20MVA 220/33kV TRANSFORMER

-

-

-

... More
220kV bushing complete in all respects.

1

-

-

... More
36kV bushing complete in all respects

1

-

-

... More
HV Neutral Bushing with metal parts and gaskets

1

-

-

... More
LV Neutral Bushing with metal parts and gaskets

1

-

-

... More
Local and Remote Winding Temperature Indicator with contact and sensing device

1

-

-

... More
Oil Temperature Indicator with contact and sensing device (Local and Remote)

1

-

-

... More
Pressure relief valve

1

-

-

... More
Magnetic oil level gauge with low oil level alarm contacts

1

-

-

... More
Cooler fan with motor

1

-

-

... More
Buchholz relay

1

-

-

... More
Set of starter, contactor relays and switches(1 No of each type)

1

-

-

... More
Tap position indicator (local & remote)

1

-

-

... More
Fuses (complete 100 % replacement for transformer)

1

-

-

... More
Lamps (complete 100% replacement for transformer)

1

-

-

... More
SPARES FOR 220kV GIS SWITCHGEAR

-

-

-

... More
220kV GIS (GENERAL):

-

-

-

... More
Complete GIS modules, along with enclosure, all active parts such as conductor, conductor joints, shields end covers etc., for each type: 1. Bus bar sections (including bus bar interconnection modules) 2. Bus Ducts sections (including compensators/expansionjoints/bellows) 3. Bends 4. SF6/Air Bushing 5. Cable termintion kit

1

-

-

... More
SF6 Gas Pressure Relief Device assembly of each type

1

-

-

... More
SF6 Pressure Gauge cum switch/Density monitors and pressure switch as applicable, of each type

5

-

-

... More
Coupling device for pressure gauge cum switch for connecting gas handling plant of each type

2

-

-

... More
Rubber gasket, 'O' rings and seals of SF6 gas for GIS enclosure type

5

-

-

... More
Molecular Filter for SF6 Gas with Filter Bags (10% of total weight)

1

-

-

... More
Control valves for SF6 gas of each type

3

-

-

... More
SF6 gas (20% of total gas quantity)

1

-

-

... More
Pipe length(copper or steel as applicable) for SF6 circuit of each type(if applicable)

2

-

-

... More
Locking device to keep the Disconnectors (isolators) and Earthing/Fast earthing switches in close or open position in cae of removal of the driving mechanism

2

-

-

... More
UHF PD sensors of each type along with BNC connector

5

-

-

... More
Support Insulators (gas through) of each type (complete with metal ring etc.,)

10

-

-

... More
Gas Barriers of each type (complete with metal ring etc.,)

10

-

-

... More
SF6 to Air bushing of each type complete in all respect

2

-

-

... More
220kV GIS CIRCUIT BREAKER

-

-

-

... More
Complete circuit breaker(one phase) without PIR with interrupter,main circui, enclosure and Marshalling Box with operating mechanism to enable one to one replacement of applicable type of CB by spare

2

-

-

... More
Fixed , moving and arcing contacts including insulating nozzles of each type (for main chamber)

1

-

-

... More
Trip Coils with Resistor as applicable

3

-

-

... More
Closing Coils with resistor as applicable

3

-

-

... More
Relays, Power Contactors, push Buttons, timers & MCB etc.of each type and rating

1

-

-

... More
Auxiliary Switch Assembly

3

-

-

... More
Operation Counter

3

-

-

... More
Windoscope, Observing Window of each type)

2

-

-

... More
For Spring Operated Mechanism

-

-

-

... More
Complete Spring operating mechanism, Including charging mechanism etc.of each type

3

-

-

... More
Spring Charging motor

2

-

-

... More
220kV GIS CURRENT TRANSFORMER

-

-

-

... More
Complete CT of each type and rating as supplied with enclosure and primary conductors to enable one to one replacement of all applicable type/rating of CT by spare.

2

-

-

... More
220kV GIS VOLTAGE TRANSFORMER

-

-

-

... More
Complete PT of each type with enclosure to enable one to one replacement of all applicable type/rating of VT by spare (if applicable)

1

-

-

... More
220kV GIS DISCONNECTING/EARTHING SWITCHES

-

-

-

... More
Complete set of 3-phase dis-connector of each type including main circuit, enclosure, driving mechanism and support Insulator etc. to enable complete one to one replacement of all applicable type of Isolator by spare

1

-

-

... More
Complete set of 3-phase Maintenance Earthing switch of each type, including main circuit, enclosure, driving mechanism and support Insulator etc to enable complete one to one replacement of all applicable type of Earth Switch by spare

1

-

-

... More
Complete set of 3-phase Fast Earthing switch of each type, including main circuit, enclosure, driving mechanism and support Insulator etc. to enable complete one to one replacement of all applicable type of Earth Switch by spare (if applicable)

1

-

-

... More
Copper Contact fingers & corona sheild for disconnector male & female contat-for one complete (3-Phase) disconnector of each type

1

-

-

... More
Copper Contact fingers & corona sheild for Maintenance Earthing switch male & female contat-for one complete (3-Phase) earthing switch of each type

1

-

-

... More
Open/close contactor assembly, timers, key interlock, interlocking coils, relays,push buttons,indicating lamps,power contactors, resistors, fuses,MCBs & drive control cards etc., one of each type for one complete MOM box

-

-

-

... More
For Disconnector

2

-

-

... More
For Maintenance Earth switch

2

-

-

... More
For Fast Earthingswitch(if applicable)

2

-

-

... More
Limit Switches and Aux. switches for one complete MOMbox

-

-

-

... More
For Disconnector

2

-

-

... More
For Maintenance Earth switch

2

-

-

... More
For Fast Earthingswitch(if applicable)

2

-

-

... More
Drive Mechanism of each type

-

-

-

... More
For Disconnector

2

-

-

... More
For Maintenance Earth switch

2

-

-

... More
For Fast Earthingswitch(if applicable)

2

-

-

... More
Motor for Drive mechanism of each type

-

-

-

... More
For Disconnector

2

-

-

... More
For Maintenance Earth switch

2

-

-

... More
For Fast Earthingswitch(if applicable)

2

-

-

... More
Local ControlCubicle(LCC)

-

-

-

... More
Aux. relays, contactors,Push buttons, switches,Lamps,Annunciation windows,MCB,Fuses, Timers, Terminal Blocks etc., of each type & rating

5

-

-

... More
SPARES FOR 220kV OUTDOOR EQUIPMENT

-

-

-

... More
220kV ISOLATOR AND EARTH SWITCH

-

-

-

... More
Complete set of 3 Nos. of single phase/1 Nos. of three phase WITH earthing switch including main circuit enclosure and driving mechanism

1

-

-

... More
Copper contact fingers for disconnector male and female contact for one complete ( 3 phase) disconnector of each type and rating

1

-

-

... More
Copper contact fingers for earthing switch male and female contact for one complete (3 phase) Earth switch of each type and rating

1

-

-

... More
Limit switches and auxiliary switches for complete three phase equipment

-

-

-

... More
a) For isolator

2

-

-

... More
b) For earth switch

1

-

-

... More
Rotor housing bearing assembly for complete three phase equipment

-

-

-

... More
a) For isolator

1

-

-

... More
b) For earth switch

1

-

-

... More
Bearing for three phase equipment

-

-

-

... More
a) For isolator

3

-

-

... More
b) For earth switch

1

-

-

... More
Interlocking coil with resistor, timers, key interlock for complete three phase

1

-

-

... More
Relays, Power Contactors, push Buttons, timers & MCB etc.of each type and rating

-

-

-

... More
a) For isolator

3

-

-

... More
b) For earth switch

1

-

-

... More
Auxiliary Switch Assembly with NO + NC (3 nos. of each type)

1

-

-

... More
SPARES FOR TARIFF METERING CURRENT TRANSFORMER

-

-

-

... More
220kV, single phase current transformer, 5 core, ratio 1200-600-300A/1-1-1-1-1A, CL- 4-PX & 1-0.2S, 30VA Metering CT complete with mounting hardware

2

-

-

... More
SPARES FOR TARIFF METERING VOLTAGE TRANSFORMER

-

-

-

... More
220kV, single phase voltage transformer ratio 220KV/√3/110V/√3V, CL-0.2, 50VA with mounting hardware

2

-

-

... More
SPARES FOR SURGE ARRESTOR

-

-

-

... More
216kV Zinc Oxide Gapless Surge Arrestor with counter and leakage meter

2

-

-

... More
SPARES FOR 33kV OUTDOOR EQUIPMENT:

-

-

-

... More
33kV Outdoor VCB, 1250A, 31.5kA/3s

1

-

-

... More
33kV Single phase current transformer, 5 core, ratio 800-400-200/1A

1

-

-

... More
33kV Single Phase, Potential Transformer, 2 core (0.2,3P classes), 33kV/110V/110V

1

-

-

... More
33kV, 1250A, 31.5kA/1s, Single phase, Outdoor Isolator with Earth Switch

1

-

-

... More
30kV Metal Oxide Surge Arrestor, 10kA, Long duration discharge class III as per technical Specification.

1

-

-

... More
33kv, 200A, Horn Gap fuses

1

-

-

... More
SPARES FOR 220V/48V DC BATTERIES

-

-

-

... More
Spare battery cell for 220V, 350AH battery w/o electrolyte

5

-

-

... More
Vent Plugs

10

-

-

... More
Float level Indicators

10

-

-

... More
Terminal connectors with nuts & bolts

10

-

-

... More
Spare battery cell for 48V, 300AH battery w/o electrolyte

5

-

-

... More
Vent Plugs

10

-

-

... More
Float Indicators

10

-

-

... More
Terminal connectors with nuts & bolts

10

-

-

... More
Electrolyte

160

-

-

... More
Battery maintenace log sheet books for two years

1

-

-

... More
SPARES FOR 220V/48V DC BATTERY CHARGER & DCDB

-

-

-

... More
Voltage regulator cards

1

-

-

... More
Protection card (if any)

1

-

-

... More
Thyristor(SCR)

2

-

-

... More
Rectifier Diods

2

-

-

... More
Blocking diode

1

-

-

... More
Filter capacitor

1

-

-

... More
Auto-manual switch

1

-

-

... More
Indicating LED

10

-

-

... More
indicating fuse (if any)

10

-

-

... More
Input AC contactor

1

-

-

... More
Rectifier H.R.C fuses

4

-

-

... More
SPARES OF LT SWITCHGEAR

-

-

-

... More
Auxiliary Relays (1 No. of each type)

1

-

-

... More
CTs and PTs (1 No. of each type)

1

-

-

... More
Switches/Push buttons and Meters (1 No. of each type)

1

-

-

... More
MCCB (1 no. of each type and rating)

1

-

-

... More
TPN Switches/MCB DP (1 No. of each type and rating)

1

-

-

... More
Voltmeters

1

-

-

... More
Ammeter

1

-

-

... More
TNC switch for breaker

2

-

-

... More
Hooter

2

-

-

... More
O/C & E/F relay

1

-

-

... More
Over Voltage coil

2

-

-

... More
Auxiliary contactors (1 No. of each type)

1

-

-

... More
L.T. Breaker Spares

-

-

-

... More
a) Spring charging motor (1 No. of each type)

1

-

-

... More
b) Aux. Contact sets (each type)

2

-

-

... More
c) Busbar Seal off insulators

5

-

-

... More
d) Arc-chutes

1

-

-

... More
e) Moving contacts (1 No. of each type)

1

-

-

... More
f) Arcing contacts (Fixed/Moving) (1 No. of each type)

1

-

-

... More
g) Springs (Closing/Opening) (1 No. of each type)

1

-

-

... More
h) Closing coil

1

-

-

... More
i) Tripping coil

1

-

-

... More
j) Aux. finger contact (1 No. of each type)

1

-

-

... More
k) Limit switches (1 No. of each type)

1

-

-

... More
l) Jaw contacts (1 No. of each type)

1

-

-

... More
m) 415V, 800A Air circuit Breaker

1

-

-

... More
Busbar

-

-

-

... More
a) Busbar insulators

5

-

-

... More
b) Interphase barrier

2

-

-

... More
c) Busbar strip (Aluminium)

5

-

-

... More
SPARES FOR RELAY AND PROTECTION PANELS 220KV

-

-

-

... More
220kV LINE PROTECTION PANEL SPARES

-

-

-

... More
Main - 1 Numerical Distance Relay with Software (excluding external Trip Relay)

1

-

-

... More
Main - 2 Numerical Current Differential Relay with Software (excluding external Trip Relay)

1

-

-

... More
220kV TRANSFORMER PROTECTION PANEL SPARES

-

-

-

... More
Numerical Differential Relay

1

-

-

... More
Numerical Restricted Earth Fault Relay

1

-

-

... More
Numerical Over Current Earth Fault Relay

1

-

-

... More
Numerical Breaker Failure Relay -If used

1

-

-

... More
Trip Circuit Supervision Relay

2

-

-

... More
Self Reset Trip Relay (1 No. of each type)

1

-

-

... More
Hand Reset Trip Relay (1 No. of each type)

1

-

-

... More
Timer Relay (1 No. of each type) -If used

1

-

-

... More
DC Supervision Relay

1

-

-

... More
Auxiliary Relays (1 No. of each type)

1

-

-

... More
High Speed Tripping relay

1

-

-

... More
220kV BUSBAR PROTECTION PANEL SPARES

-

-

-

... More
Power Supply Modules for Bus Bar Protection (1 No. of each type)

3

-

-

... More
Metrosil (Non - Linear Resistor) (1 No. of each type)

1

-

-

... More
SPARES FOR SUB STATION AUTOMATION SYSTEM

-

-

-

... More
Fan assembly used for Master station, HMI, Printer server (each type)

1

-

-

... More
Bay Control Unit of each type with configuration software

2

-

-

... More
Auxiliary relays used in bay control unit for control applications (10% of Total)

1

-

-

... More
FO patch card of each type

5

-

-

... More
OFC cable

500

-

-

... More
optical loss measuring kit with relevant accessories and visual Fiber Optic cable inspection aid for optical fibre cable

1

-

-

... More
Industrial Ethernet switch of each type

1

-

-

... More
SPARES FOR EOT CRANE

-

-

-

... More
Spares for 220kV GIS Hall Crane

-

-

-

... More
Pair of brake shoe with lining for each size of brake used viz. D.C. operated E.M, or Hydraulic thruster operated.

4

-

-

... More
Pair of brake linings with rivets for each size of brake used.

4

-

-

... More
Main springs for each size of brake used.

4

-

-

... More
Brake coils for each size of brake used.

4

-

-

... More
Thruster of each size used.

2

-

-

... More
Pair of oil seals for each gear box used on crane.

4

-

-

... More
Contactors of each size used.

4

-

-

... More
Fixed & moving contacts of each size contactor used.

2

-

-

... More
3 Nos. Coils for each size of contactor used.

2

-

-

... More
Overload relay for each motor.

2

-

-

... More
Timers

6

-

-

... More
3 No. fuse links of each sizes used on crane

4

-

-

... More
1 Printed circuit breaker of each size and type

1

-

-

... More
Complete set of lamps for lightning and signals

1

-

-

... More
Carbon brushes & holdings for each slip ring motor

4

-

-

... More
Fuse links of each size used

4

-

-

... More
Resistance element of each size and type

1

-

-

... More
Communication Card/cable

1

-

-

... More
I/O Card

1

-

-

... More
Processors

1

-

-

... More
Indicating lamps

1

-

-

... More
SPARES FOR FIRE DETECTION AND FIRE EXTINGUISHING SYSTEM

-

-

-

... More
Fitted Nitrgen Cylinder

2

-

-

... More
Pipes with fittings

1

-

-

... More
Heat Sensor assembly

1

-

-

... More
Fire Survival cable sufficient for one system

1

-

-

... More
Fire Detectors

6

-

-

... More
Thermostat

2

-

-

... More
SPARES FOR FIBER OPTICAL TERMINAL EQUIPMENT (FOTE)

-

-

-

... More
Power Supply Card (48 V DC)

1

-

-

... More
Control Card with alarm cables and terminals

1

-

-

... More
STM - 1 OLTE - 4 SFP cages excluding SFP

1

-

-

... More
SFP U1.2 ( 1550 nm for Distance of 160 km)

1

-

-

... More
Fibre Patch Cord for OLTE - 10 m

4

-

-

... More
2/4 wire E & M speech interface card ports

1

-

-

... More
Integrated teleprotection couler - 4 commands

1

-

-

... More
Low and High Speed data Interface Card - 4 Ports

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.