Odisha Power Transmission Corporation Limited Tender

Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.

Odisha Power Transmission Corporation Limited - OPTCL Tender

Eprocure
Opening Date10 Sep 2018
Closing Date1 Oct 2018
Tender Amount₹ 40,53,17,585 
Notes
Download

Costs

Summary

Construction Of Proposed Sldc Office Complex (multi-storied)

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Earth work in hard soil or gravelly soil within 50m. Initial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per the direction of the Engineer-in-charge.+3.0m extra lift.

1046.77

163044

155.76

... More
Supplying & Filling foundation trenches , plinth & ditches with clean course river sand well watered and rammed in layers not exceeding 23 c.m. in depth with all lead and lift including cost, conveyance, loading, unloading, stacking,royalties and all taxes of sand,cost & conveyance of water, cost of all Labour,labour cess,T&P required for the work etc. complete in all respect as directed by the Engineer- in -charge.

878.41

281706

320.7

... More
Back filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5m.

5134.57

506782

98.7

... More
Disposal of surplus excavted materials by mechanical means from the work side etc. complete. upto 5km. Lead

3977.72

601311

151.17

... More
Providing and laying Plain cement concrete of proportion(1:3:6) in foundation and floors(i.e. below the base course of the flooring) using cement, 40mm. Size crusher broken H.G.Metal and screened and washed sharp river sand for mortar of approved quality and from approved quarry inclduign hoisting, lowering and laying concrete to the required level, ramming,watering and curing etc. completek to required levels, laid in layers not exceeding 15cm thick in each layer including cost, conveyance, loading, unloading,royalities and taxes of all materials, cost of all labour,T&P required for the work including shoring,shuttering anddewatering(if required)including hire and running charges of water pump required for the work etc. complete in all respect as directed by the Engineer-in-charge.

943.3

3754711

3980.4

... More
Providing and laying in position ready mixed M-30 grade concrete having compressive strength at 28 days test not less than 300 kg/ sq.cm for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying , including the cost of centering, shuttering finishing and excluding reinforcement including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, and hoisting, lowering, laying and compacting concrete, watering and curing and finishing the exposed surfaces smooth with cost, conveyance, royalties, taxes of all materials with all labour,Labour cess and T&P required for the work improve workability without impairing strength and durability as per direction of the Engineer - in - charge.

1

-

-

... More
FOUNDATION AND BASEMENT FLOOR

2

-

-

... More
Foundation & Plinth

2755.05

13534458

4912.6

... More
RCC in Grade beam

28.53

148783

5215

... More
RCC in column from raft slab top to Basement roof

138.72

1262657

9102.2

... More
RCC in roof beam (Plinth Beam)

126.33

1149880

9102.2

... More
RCC in roof slab

366.79

2992272

8158

... More
RCC in Stair case

13.54

117871

8705.4

... More
RCC in Lintel

3.12

24287

7784.6

... More
RCC in Sill

1.52

11832

7784.6

... More
RCC Wall

347.28

2247075

6470.5

... More
GROUND FLOOR

1

-

-

... More
RCC in column

83.82

762946

9102.2

... More
RCC in roof beam

52.31

476136

9102.2

... More
RCC in roof slab

158.42

1292390

8158

... More
RCC in Stair case

15.6

135804

8705.4

... More
RCC in Lintel

11.27

87732

7784.6

... More
RCC in Sill

6.56

51066

7784.6

... More
RCC in Chajja

8.71

5941

682.1

... More
RCC Wall

63.93

413659

6470.5

... More
Platform Slab

13.97

9528

682.1

... More
FIRST FLOOR

1

-

-

... More
RCC in column

73.84

740282

10025.5

... More
RCC in roof beam

53.39

535261

10025.5

... More
RCC in roof slab

157.2

1397775

8891.7

... More
RCC in Stair case

15.6

148965

9549.1

... More
RCC in Lintel

8.69

73379

8444.1

... More
RCC in Sill

5.21

43993

8444.1

... More
RCC in Chajja

8.71

6621

760.2

... More
RCC Wall

43.31

297405

6866.9

... More
Platform Slab

7.76

5899

760.2

... More
SECOND FLOOR

1

-

-

... More
RCC in column

72.79

810167

11130.2

... More
RCC in roof beam

53.39

594241

11130.2

... More
RCC in roof slab

155.18

1515984

9769.2

... More
RCC in Stair case

15.6

164714

10558.6

... More
RCC in Lintel

12.54

115775

9232.5

... More
RCC in Sill

7.52

69428

9232.5

... More
RCC in Chajja

8.71

7435

853.7

... More
RCC Wall

43.31

317882

7339.7

... More
Platform Slab

2.64

2253

853.7

... More
THIRD FLOOR

1

-

-

... More
RCC in column

72.79

906410

12452.4

... More
RCC in roof beam

48.88

608673

12452.4

... More
RCC in roof slab

129.71

1403384

10819.4

... More
RCC in Stair case

15.6

183554

11766.3

... More
RCC in Lintel

13.19

134213

10175.4

... More
RCC in Sill

7.91

80487

10175.4

... More
RCC in Chajja

8.71

8411

965.7

... More
RCC Wall

43.31

342317

7903.9

... More
Platform Slab

5.64

5446

965.7

... More
FOURTH FLOOR

1

-

-

... More
RCC in column

67.16

942604

14035.2

... More
RCC in roof beam

46.17

648005

14035.2

... More
RCC in roof slab

135.21

1632850

12076.4

... More
RCC in Stair case

15.6

206102

13211.7

... More
RCC in Lintel

10.98

124104

11302.8

... More
RCC in Sill

6.61

74711

11302.8

... More
RCC in Chajja

8.71

9580

1099.9

... More
RCC Wall

43.31

371487

8577.4

... More
Platform Slab

5.64

6203

1099.9

... More
FIFTH FLOOR

1

-

-

... More
RCC in column

68.55

1091987

15929.8

... More
RCC in roof beam

46.17

735478

15929.8

... More
RCC in roof slab

135.68

1842371

13578.8

... More
RCC in Stair case

15.6

233099

14942.3

... More
RCC in Lintel

11.08

140170

12650.8

... More
RCC in Sill

6.67

84380

12650.8

... More
RCC in Chajja

8.71

10978

1260.5

... More
RCC Wall

43.31

406260

9380.3

... More
Platform Slab

4.62

5823

1260.5

... More
SIXTH FLOOR

1

-

-

... More
RCC in column

68.55

1247500

18198.4

... More
RCC in roof beam

46.17

840220

18198.4

... More
RCC in roof slab

135.68

2086459

15377.8

... More
RCC in Stair case

15.6

265409

17013.4

... More
RCC in Lintel

11.46

163460

14263.6

... More
RCC in Sill

6.9

98418

14263.6

... More
RCC in Chajja

8.71

12655

1453

... More
RCC Wall

43.31

447795

10339.3

... More
Platform Slab

5.64

8194

1453

... More
SEVENTH FLOOR

1

-

-

... More
RCC in column

68.55

1433736

20915.2

... More
RCC in roof beam

46.17

965654

20915.2

... More
RCC in roof slab

135.68

2378416

17529.6

... More
RCC in Stair case

15.6

304075

19492

... More
RCC in Lintel

10.47

169534

16192.4

... More
RCC in Sill

6.4

103631

16192.4

... More
RCC in Chajja

8.71

14664

1683.6

... More
RCC Wall

43.31

497354

11483.6

... More
Platform Slab

4.62

7778

1683.6

... More
EIGHTH FLOOR

1

-

-

... More
RCC in column

68.55

1656695

24167.7

... More
RCC in roof beam

46.17

1115822

24167.7

... More
RCC in roof slab

135.68

2727832

20104.9

... More
RCC in Stair case

15.6

350390

22460.9

... More
RCC in Lintel

9.34

172804

18501.5

... More
RCC in Sill

5.46

101018

18501.5

... More
RCC in Chajja

8.71

17069

1959.8

... More
RCC Wall

43.31

556529

12849.9

... More
Platform Slab

7.95

15580

1959.8

... More
NINETH FLOOR

1

-

-

... More
RCC in column

68.55

1923725

28063.1

... More
RCC in roof beam

46.17

1295673

28063.1

... More
RCC in roof slab

141.57

3282711

23187.9

... More
RCC in Stair case

4.89

127209

26014.2

... More
RCC in Lintel

9.34

198606

21264.1

... More
RCC in Sill

5.46

116101

21264.1

... More
RCC in Chajja

8.71

19952

2290.8

... More
RCC Wall

43.31

627211

14481.9

... More
Platform Slab

7.95

18211

2290.8

... More
TERRACE FLOOR

1

-

-

... More
RCC in column

29.91

978918

32728.8

... More
RCC in roof beam

17.31

566535

32728.8

... More
RCC in roof slab

51.41

1381849

26879

... More
RCC in Lintel

3

73707

24569

... More
RCC in Sill

1.91

46926

24569

... More
RCC in Chajja

6.75

18139

2687.4

... More
RCC Wall

39.37

646908

16431.5

... More
Double stage centring & shuttering for Roof slab, balconies & projection above 3.60 mtr up to 7.20mtr heights with cost of all Labour, Labour cess ,Hire & Running charges of the water pumps, Sundries, T & P required for the work complete as directed by the Engineer- in- charge.

1

-

-

... More
First floor

31.34

22245

709.8

... More
Fourth FLoor

25.23

25787

1022.1

... More
Cutting,straightening coiled or bent up HYSD/TMT Reinfocement Bars welding or jointing if necessary ,bending, binding,tying the grills as required for R.C.C. works,providing Fan Hooks where necessary and hoising,lowering and placing the same tin proper position according to the approved eesigns and drawings in all floors including cost, conveyance, loading, unloading and taxes or HYSD/TMT Reinforcement Bars and Binding wieres of 18 to 20 gauge required for the work cost of all labour,T&P and scaffolding complete in all respect as directed by the Engineer-in-charge(Payment will be made according to the actual/proper weight of HYSD/TMT Reinforcement Bars and Binding wires consumed in the particular work only)

1

-

-

... More
Foundation

2370.32

15188990

6408

... More
Basement

961.79

6163135

6408

... More
GROUND FLOOR

381.66

2445677

6408

... More
First floor

345.82

2221552

6424

... More
SECOND FLOOR

350.39

2256812

6440.8

... More
THIRD FLOOR

324.41

2095173

6458.4

... More
Fourth FLoor

316.64

2050881

6477

... More
FIFTH FLOOR

318.59

2069684

6496.4

... More
SIXTH FLOOR

319.41

2081533

6516.8

... More
SEVENTH FLOOR

317.49

2075859

6538.3

... More
EIGHTH FLOOR

315.08

2067155

6560.8

... More
NINETH FLOOR

309.67

2038974

6584.4

... More
TERRACE FLOOR

139.34

920925

6609.2

... More
Aerated Autoclaved Concrete blocks of size 625mmX200mmX200mm having compressive strength more than 4N/ sqmm confirming to IS:2185-Part-3-1984 & IS:6441-1972 of Lean/Aerolite or equivalent products in cement mortar of mix (1:6) using cement of approved quality, screened & washed sand for use in super structure including splays cutting, circular moulding , corbrlling, champering & similar such type of works, watering & curing etc. including cost, conveyance, royalty, loading, unloading of all materials, cost of labour, scaffolding, sundries, T & P required for the works etc. complete in all respect as directed by the Engineer-in-charge.

1

-

-

... More
Basement Floor

50.58

204555

4044.2

... More
GROUND FLOOR

198.83

810735

4077.53

... More
FIRST FLOOR

149.32

609972

4085

... More
SECOND FLOOR

226.6

936288

4131.9

... More
THIRD FLOOR

239.58

1002833

4185.8

... More
Fourth FLoor

201.97

857928

4247.8

... More
FIFTH FLOOR

199.68

862457

4319.2

... More
SIXTH FLOOR

204.41

899649

4401.2

... More
SEVENTH FLOOR

186.53

838545

4495.5

... More
EIGHTH FLOOR

158.24

728536

4604

... More
NINETH FLOOR

158.24

748285

4728.8

... More
TERRACE FLOOR

73.22

356749

4872.3

... More
Providing 12mm. Thick cement plaster in cement mortar or mix(1:6) in all floors at all height with cement & screened and washed sharp river sand for mortar and finished smooth to the rough surface of the brick masonary walls after racking out the joints (alongwith providing grooves wherever necessary) including watering and curing,rounding of corners etc. complete with cost, conveyance, loading, unloading, royalities and taxes of all materials,cost of all labour,T&P, and scaffolding required for the work etc. as directed by the Engineer-in-charge. (Outer side)

1

-

-

... More
GROUND FLOOR

718.04

71947

100.2

... More
FIRST FLOOR

711.18

73891

103.9

... More
SECOND FLOOR

751.6

81022

107.8

... More
THIRD FLOOR

746.7

83555

111.9

... More
Fourth FLoor

860.74

100018

116.2

... More
FIFTH FLOOR

810.07

97775

120.7

... More
SIXTH FLOOR

802.4

100620

125.4

... More
SEVENTH FLOOR

802.23

104611

130.4

... More
EIGHTH FLOOR

801.32

108658

135.6

... More
NINETH FLOOR

801.32

113066

141.1

... More
TERRACE FLOOR

674.43

99074

146.9

... More
Providing 12mm. Thick cement plaster in cement mortar or mix(1:6) in all floors at all height with cement & screened and washed sharp river sand for mortar and finished smooth to the rough surface of the brick masonary walls after racking out the joints (alongwith providing grooves wherever necessary) including watering and curing,rounding of corners etc. complete with cost, conveyance, loading, unloading, royalities and taxes of all materials,cost of all labour,T&P, and scaffolding required for the work etc. as directed by the Engineer-in-charge. (Inside)

1

-

-

... More
BASEMENT FLOOR

784.31

78588

100.2

... More
GROUND FLOOR

1779

178256

100.2

... More
FIRST FLOOR

1410.31

144415

102.4

... More
SECOND FLOOR

2343.83

245399

104.7

... More
THIRD FLOOR

2526.02

270284

107

... More
Fourth FLoor

1928.31

211149

109.5

... More
FIFTH FLOOR

1961.48

219685

112

... More
SIXTH FLOOR

2117.67

242684

114.6

... More
SEVENTH FLOOR

1798.62

210798

117.2

... More
EIGHTH FLOOR

1464.87

175784

120

... More
NINETH FLOOR

1464.87

179885

122.8

... More
TERRACE FLOOR

386.36

48564

125.7

... More
Providing 6 mm thick cement plaster in cement mortar of mix (1:4) at all height using screened & washed sharp river sand for mortar with approved quality of cement to the ceiling of the Roof Slab, Staircase, Beams, Columns,Landings, Railings,Chajja ,Fins ,Walls ,Jally and Shelves etc. including roughening, scraping, chiseling, cleaning, closed deep chipping with slurry treatment and finished smooth to all R.C.C. Surface including cost, conveyance, loading, unloading, royalties ,stacking and all taxes , cost of all Labour,Labour cess ,Sundries, T&P, Scaffolding, Watering, Curing etc. complete in all respect as directed by the Engineer- in- charge.

1

-

-

... More
BASEMENT FLOOR

3918.46

417707

106.6

... More
GROUND FLOOR

1424.68

151870

106.6

... More
FIRST FLOOR

1505.29

164227

109.1

... More
SECOND FLOOR

1400.78

156327

111.6

... More
THIRD FLOOR

1579.6

180390

114.2

... More
Fourth FLoor

1633.86

190998

116.9

... More
FIFTH FLOOR

1634.22

195615

119.7

... More
SIXTH FLOOR

1637.88

200640

122.5

... More
SEVENTH FLOOR

1634.66

205149

125.5

... More
EIGHTH FLOOR

1655.23

212697

128.5

... More
NINETH FLOOR

1576.49

207466

131.6

... More
TERRACE FLOOR

1046.49

141066

134.8

... More
Priming one coat with af approved quality of primer of approved make including cost, conveyance and taxes of all materials & cost ,conveyance taxes of all labour with T & P required etc complete in all respect as per the direction of the Eng.-in-charge

1

-

-

... More
BASEMENT FLOOR

4702.78

204100

43.4

... More
GROUND FLOOR

3921.71

170202

43.4

... More
FIRST FLOOR

3626.78

161029

44.4

... More
SECOND FLOOR

4496.21

204127

45.4

... More
THIRD FLOOR

4852.32

225147

46.4

... More
Fourth FLoor

4422.91

209646

47.4

... More
FIFTH FLOOR

4405.76

213679

48.5

... More
SIXTH FLOOR

4557.95

226074

49.6

... More
SEVENTH FLOOR

4235.51

214740

50.7

... More
EIGHTH FLOOR

3921.42

203521

51.9

... More
NINETH FLOOR

3842.68

204046

53.1

... More
TERRACE FLOOR

2107.27

114635

54.4

... More
Finishing wall surface of walls with cement based wall putty ( water based) of approved make and finished smooth and even surface to receive painting including cost, conveyance ,taxes of all materials , cost of all Labour , Labour cess,scaffoldings, staging, sundries,T&P etc. required for the work complete as directed by the Engineer-in-charge.

40613.28

2213423

54.5

... More
Wall painting two coats with Acrylic paint(plastic emulsion) of approved quality of premium brand of approved quality & colour at all heights to the interior surface of the wall to make an even finished surface including sand papering, applying putty wherever necessary including cost, conveyance, loading, unloading, stacking, all taxes , cost of all Labour , Labour cess,scaffoldings, staging, sundries,T&P etc. required for the work complete as directed by the Engineer-in-charge.

1

-

-

... More
BASEMENT FLOOR

4702.78

290161

61.7

... More
GROUND FLOOR

3203.68

197666

61.7

... More
FIRST FLOOR

2915.6

182807

62.7

... More
SECOND FLOOR

3744.61

238906

63.8

... More
THIRD FLOOR

4105.62

266454

64.9

... More
Fourth FLoor

3562.17

234747

65.9

... More
FIFTH FLOOR

3595.69

241270

67.1

... More
SIXTH FLOOR

3755.55

256504

68.3

... More
SEVENTH FLOOR

3433.28

238612

69.5

... More
EIGHTH FLOOR

3120.1

220902

70.8

... More
NINETH FLOOR

3041.36

219282

72.1

... More
TERRACE FLOOR

1432.84

105170

73.4

... More
Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm.

8480.03

1136324

134

... More
Forming groove of uniform size (15 mm wide and 15 mm deep groove) in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer, including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge :

4850.2

115386

23.79

... More
Providing 16mm. Thick cement plaster in cement mortar or mix(1:6) in all floors at all height with cement & screened and washed sharp river sand for mortar and finished smooth to the rough surface of the brick masonary walls after racking out the joints (alongwith providing grooves wherever necessary) including watering and curing,rounding of corners etc. complete with cost, conveyance, loading, unloading, royalities and taxes of all materials,cost of all labour,T&P, and scaffolding required for the work etc. as directed by the Engineer-in-charge. (Outer side for double plaster)

1

-

-

... More
GROUND FLOOR

257.04

36705

142.8

... More
FIRST FLOOR

257.99

37692

146.1

... More
SECOND FLOOR

261.95

39187

149.6

... More
THIRD FLOOR

261.95

40104

153.1

... More
Fourth FLoor

261.95

41073

156.8

... More
FIFTH FLOOR

261.95

42069

160.6

... More
SIXTH FLOOR

261.93

43061

164.4

... More
SEVENTH FLOOR

261.95

44112

168.4

... More
EIGHTH FLOOR

261.95

45212

172.6

... More
NINETH FLOOR

261.95

46312

176.8

... More
Providing matt finished double charged vitrified tile flooring using vitrified tiles having thickness of 8mm to 10mm conforming to IS 13755 of 600mmx1200mm (Plain Ivory) (homogeneous) of premium quality in floors, treads on steps and landings on 20mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened and washed sharp sand for mortar and fixing with neat white cement slurry,grouting the joints with neat white cement slurry mixed with required quantities of pigments of approved make to match the shades of the vitrified tile if required , watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour,Labour cess , sundries, T&P required for the work, complete in all respect as per specification and direction of Engineer-in-charge.

1

-

-

... More
BASEMENT FLOOR

11.62

12835

1104.6

... More
GROUND FLOOR

18.11

20004

1104.6

... More
FIRST FLOOR

15.03

16698

1111

... More
SECOND FLOOR

114.5

127976

1117.7

... More
THIRD FLOOR

217.95

245128

1124.7

... More
Fourth FLoor

453.58

513497

1132.1

... More
FIFTH FLOOR

513.95

585851

1139.9

... More
SIXTH FLOOR

569.65

653958

1148

... More
SEVENTH FLOOR

521.76

603467

1156.6

... More
EIGHTH FLOOR

610.06

711024

1165.5

... More
NINETH FLOOR

610.06

716820

1175

... More
Providing matt finished double charged vitrified tile in dado/ skirting using vitrified tiles having thickness of 8mm to 10mm conforming to IS 13755 of 600mmx1200mm, (Plain Ivory) (homogeneous) in dado/ skirting,riser of steps,wall on on 12mm thick bed of cement mortar of mix (1:3) laid in proper slope and gradient with screened and washed sharp sand for mortar and fixing with neat white cement slurry,grouting the joints with neat white cement slurry mixed with required quantities of pigments of approved make to match the shadesof the vitrified tile if required watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, Labour cess ,sundries, T&P required for the work, complete in all respect as per specification and direction of Engineer-in-charge.

1

-

-

... More
BASEMENT FLOOR

2.08

2542

1222.2

... More
GROUND FLOOR

89.83

109790

1222.2

... More
FIRST FLOOR

3.47

4274

1231.8

... More
SECOND FLOOR

109.08

135455

1241.8

... More
THIRD FLOOR

254.82

319136

1252.4

... More
Fourth FLoor

30.21

38170

1263.5

... More
FIFTH FLOOR

29.51

37631

1275.2

... More
SIXTH FLOOR

40.86

52607

1287.5

... More
SEVENTH FLOOR

69.63

90539

1300.3

... More
EIGHTH FLOOR

26.69

35065

1313.8

... More
NINETH FLOOR

26.29

34913

1328

... More
Providing Granite stone matt finished 20mm thick of area above 0.40 Sqm in flooring of approved quality, colour and size in floors, treads on steps and landings in all floors at all height on 20mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened and washed sharp sand for mortar and fixing with neat white cement slurry,grouting the joints with neat white cement slurry mixed with required quantities of pigments of approved make to match the shades of the granite tile if required watering and curing for 21 days, including edge moulding at required places including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, Labour cess ,sundries, T&P required for the work etc. complete in all respect as per specification and direction of Engineer-in-charge.

1

-

-

... More
BASEMENT FLOOR

151.24

367724

2431.4

... More
GROUND FLOOR

508.17

1235564

2431.4

... More
FIRST FLOOR

267.08

655254

2453.4

... More
SECOND FLOOR

236.51

585717

2476.5

... More
THIRD FLOOR

443.08

1108010

2500.7

... More
Fourth FLoor

170.89

431685

2526.1

... More
FIFTH FLOOR

169.87

433661

2552.9

... More
SIXTH FLOOR

170.89

441050

2580.9

... More
SEVENTH FLOOR

135.63

354048

2610.4

... More
EIGHTH FLOOR

213.68

564392

2641.3

... More
NINETH FLOOR

163.52

437219

2673.8

... More
TERRACE FLOOR

10.32

27945

2707.9

... More
Providing Granite stone prepolished 10mm thick of area above 0.40 Sqm in dado/skirting,riser of steps of approved quality, colour and size in dado/ skirting,riser of steps,wall on 12mm thick bed of cement mortar of mix (1:3) laid in proper plumb and line with screened and washed sharp sand for mortar and fixing with neat white cement slurry,grouting the joints with neat white cement slurry mixed with required quantities of pigments of approved make to match the shades of the granite tile if required watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, Labour cess ,sundries, T&P required for the work etc. complete in all respect as per specification and direction of Engineer-in-charge.

1

-

-

... More
BASEMENT FLOOR

94.4

161170

1707.3

... More
GROUND FLOOR

235.94

402820

1707.3

... More
FIRST FLOOR

208.76

360674

1727.7

... More
SECOND FLOOR

157.42

275343

1749.1

... More
THIRD FLOOR

159.14

281932

1771.6

... More
Fourth FLoor

153.7

275922

1795.2

... More
FIFTH FLOOR

151.66

276021

1820

... More
SIXTH FLOOR

153.7

283730

1846

... More
SEVENTH FLOOR

151.66

284104

1873.3

... More
EIGHTH FLOOR

182.8

347685

1902

... More
NINETH FLOOR

155.58

300596

1932.1

... More
TERRACE FLOOR

8.19

16082

1963.7

... More
25mm thick AS flooring with cement concrete in proportion (1:2:4) using black hard crusher broken granite chips laid in two layers , the bottom layer being 20mm thick and the top layer 6mm thick with cement punning laid over 100mm thick metal concrete including watering,curing etc complete including cost, conveyance royalties and taxes of all materials and cost of all labour with T&P required for the work etc complete in all respects as per the direction of the Engineer in charge.

1

-

-

... More
BASEMENT FLOOR

67.5

15815

234.3

... More
GROUND FLOOR

29.42

6893

234.3

... More
FIRST FLOOR

29.42

7093

241.1

... More
SECOND FLOOR

29.42

7304

248.3

... More
THIRD FLOOR

29.42

7525

255.8

... More
Fourth FLoor

29.42

7758

263.7

... More
FIFTH FLOOR

29.42

8002

272

... More
SIXTH FLOOR

29.42

8261

280.8

... More
SEVENTH FLOOR

29.42

8528

289.9

... More
EIGHTH FLOOR

29.42

8811

299.5

... More
NINETH FLOOR

29.42

9108

309.6

... More
Providing, laying, commissioning homogeneous vinyle anti static seam less flooring of 2.00 mm thick having net wet of 3 Kg / sqmt, static electrical charges 2KV , under floor heating (max 27 degree centigrade , thermal resistance approx. 0.01sqm K/W , Light fastness = level 6 with good resistance ,all complete as per direction of EIC.

141.78

374013

2638

... More
Supplying, fitting and fixing of Antiskid Ceramic Floor Tiles in flooring using special plain / printed series Ceramic Floor Tile of premium grade ( having minimum thickness 7 mm to 8 mm & size 400 mm x400 mm, confirming to I.S 13755 of approved quality and shade in floors, treads on steps and landings on 25 m.m thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened & washed sharp river sand for mortar and fixing with neat white cement slurry,grouting the joints with neat white cement slurry mixed with required quantities of pigments (Tiles are to be immersed in the water for required time before use) of approved make to match the shades of the Ceramic Floor Tiles if required including cost, conveyance, loading, unloading, stacking, royalties , all taxes,rubbing, cost of all Labour, Labour cess ,Sundries, T&P required for the work , Watering , Curing for required days , cleaning the flooring space manually etc. complete in all respect as directed by the Engineer-in-charge.

1

-

-

... More
GROUND FLOOR

56.78

34510

607.8

... More
FIRST FLOOR

43.91

26969

614.2

... More
SECOND FLOOR

43.91

27263

620.9

... More
THIRD FLOOR

51.11

32091

627.9

... More
Fourth FLoor

49.43

31406

635.3

... More
FIFTH FLOOR

47.06

30264

643.1

... More
SIXTH FLOOR

59.95

39039

651.2

... More
SEVENTH FLOOR

46.23

30502

659.8

... More
EIGHTH FLOOR

38.58

25798

668.7

... More
NINETH FLOOR

38.58

26164

678.2

... More
Supplying, fitting & fixing of Ceramic wall Tile (30x30 cm / 20x20 cm special plain / printed) series tiles in dadoes, skirting and risers of steps of size 600mmx 600mm of approved make confirming to IS:13755 laid on 12 mm thick cement mortar (1:3) (1 cement : 3 course sand) jointed with slurry mixed with pigment to match the shades of the tiles etc. complete including cost of all materials,rubbing, labour T&P etc. required for the work all complete as per direction of the Engineer-in-charge .

1

-

-

... More
GROUND FLOOR

137.74

118053

857.1

... More
FIRST FLOOR

120.67

105884

877.5

... More
SECOND FLOOR

120.67

108466

898.9

... More
THIRD FLOOR

153.43

141366

921.4

... More
Fourth FLoor

150.91

142606

945

... More
FIFTH FLOOR

135.79

131685

969.8

... More
SIXTH FLOOR

198.79

197951

995.8

... More
SEVENTH FLOOR

135.16

138278

1023.1

... More
EIGHTH FLOOR

101.14

106374

1051.8

... More
NINETH FLOOR

101.14

109419

1081.9

... More
Providing and laying machine cut, mirror polished, Italian Marble stone flooring laid in required pattern in linear portion of the building all complete as per architectural drawings, with 18 mm thick stone slab laid over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with white cement slurry @ 4.4 kg/sqm, including pointing with white cement slurry admixed with pigment to match the marble shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.(18 mm thick Italian Marble stone slab, Perlato, Rosso verona, Fire Red or Dark Emperadore etc.)

1

-

-

... More
GROUND FLOOR

222.57

1082567

4863.94

... More
Providing and fixing machine cut, mirror/ eggshell polished , Marble stone work for wall lining (veneer work) including dado, skirting, risers of steps etc., in required design and pattern wherever required, stones of different finished surface texture, on 12 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) laid and jointed with white cement slurry @ 3.3 kg/sqm including pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing, polishing etc. all complete as per Architectural drawings, and as directed by the Engineer-in-Charge.(18 mm thick Italian Marble stone slab, Perlato, Rosso verona, Fire Red or Dark Emperadore etc. )

498.83

2971350

5956.64

... More
Providing and fixing Granite Stone of approved shade slab with table rubbed, edges rounded and both sides polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth.

36

101952

2832

... More
Supply of 600X600mm Unitile® Make Raised Access Flooring System using USF 800 Grade Panel / Tile with top performance finish of 1.2mm  High Pressure Antistatic Laminate (HPL IT)  with Edge Support Rigid Grid (ESRG) System able to take Concentrated Loads : 363 Kgs (800 lbf ), Uniformly Distributed Load (UDL): 1650kg/m2 and Pedestal Axial Load: 22kN suitable for required areas as per direction of Engineer-in-charge

1

-

-

... More
Material @ 2.77 pieces in 1 sqmt (Panel with 2% wastage)

2654

2086044

786

... More
Pedestal of 150mm high with 4% wastage @ 3.33 pieces in 1 sqmt

394

34672

88

... More
Pedestal of 300mm high with 4% wastage @ 3.33 pieces in 1 sqmt

795

79500

100

... More
Pedestal of 450mm high with 4% wastage @ 3.33 pieces in 1 sqmt

2066

227260

110

... More
Stringer 16X29X0.8mm with 2% wastage @ 5.5 pieces in 1 sqmt

5270

210800

40

... More
PVC cap with 4% wastage @ 3.33 pieces in 1 sqmt

3253

30903

9.5

... More
Stringer Screw with 2% wastage @ 13 pieces in 1 sqmt

12455

31137

2.5

... More
Swell Head Pedestal for Shoe Ramp

150

150

1

... More
Total no of racks in PMU, SCADDA & Server equipment room=14 nos @ 2pieces of Airflow Grill with Damper per rack

28

112000

4000

... More
Ramp shoe 3000X165mm

4

46000

11500

... More
Providing and fixing lamiwood laminate wooden flooring in approved pattern i.e. ' wood grain' , shade and size different textures of laminate flooring. The wooden floor tile shall have texture and shade of natural grains look. The thickness of wooden flooring tile shall be between 8-12mm having size of apx 200mmx1200mm. The lamiwood laminate wooden floor should be made from HDF top importand paper and top high abrasion resistance overlay, The fixing of lamiwood laminate wooden floor tile should take place on Pcc or tile zero level floor , top will used 2mm foam and top wooden floor fix with interluck system.

741.95

1099056

1481.31

... More
Surface Preparation: The substrate must be cleaned properly to remove all dust, dirt etc. The concreteshould becuring for 7 days prior to go for other activity. Curing by normal water. The substrate must be in SSD condition (saturated surface dry).Pre-wet the substrate up to one day in advance, so that the surface of the substrate can dry off prior further installations. Bond slurry Preparation: The substrate can be dry or slightly moist, but must not be wet (glossy) when applying the cement Bond slurry. We recommend to make the substrate in SSD condition (saturated surface dry) Laying M25 grade plain cement concrete including necessary shuttering in leveling courses under foundations, pipelines, pits, under floors and all other allied works whatever required for completion of the building , at any place, level and locations all as directed by the consultant and Engineer In Charge and as detailed in the drawing. Minimum quantity of cement for M-25 grade concrete shall be 360 kgs/Cum using 43 grade OPC.Finishing the top concrete surface of flooring laid under above item by providing vacuum dewatering system ”Trimix” including finishing the top using Floater machine to a smooth and fair surface. (VDF Flooring). In Basement FLoor.

271.79

416213

1531.4

... More
Epoxy Flooring Application for car parking area: Providing and applying a coat of epoxy resin based primer for concrete surface with MYK Indufloor 1290(I) @ 0.30kg/sqm.Application of Textured Epoxy topping:Providing and applying chemical and abrasion resistant thixotropic epoxy resin textured antiskid topping(Non Broadcast) MYK Deck CoatM Having a mixed density of 1.70 kg/ltr and @ 0.8kg/sqm to bring out even crested finish having a thickness of aprox1.5-2 mm from crest.

2475.46

1655538

668.78

... More
Application of Line Marking:Providing and applying abrasion resistant epoxy resin topping(Non Broadcast) MYK Indufloor EC @ 0.07kg/Rmt in desired colour and as per the drawing. In Basement Floor.

718.36

122444

170.45

... More
Application of Arrow: Providing and applying abrasion resistant epoxy resin topping(Non Broadcast) MYK Indufloor EC @ 1.5m2/kgin desired colour and as per the drawing.(in BASEMENT)

7.5

3352

447.05

... More
For Ramp Area: Prime the surface using MYK Indufloor 1290(I) @ 0.3 kg/m2. Application of Base Coat: Apply MYK Indufloor 1290(I) @ 0.60 kg/m2 evenly using an English trowel and subsequently, if required, use a short piled lamb’s roller to smoother all the trowel edge marks. Spreading of Silica Quartz: Immediately after application of MYK Indufloor 1290(I), while it is still wet, BROADCAST silica quartz having mesh size of 0.7 to 1.0 @ 2.5 kg/m2. Application of Sealer Coat: Evenly apply MYK Indufloor EC @ 0.800kg/m2in 2 coats using a lamb’s wool short piled roller. Ensure excess material does smoothen the broadcast surface

242.4

224427

925.85

... More
Supply and installation of 1.2 mm thick MYK POWER PRUFE 800 below grade pre-applied integrally bonded waterproofing sheet membrane composed of 0.7 mm thick HDPE backing layer and a trafficable weather resistant protective granular layer realizing a firm bonding to poured concrete to prevent water ingress applied on prepared sub base and shoring prior to casting of concrete. The membrane is loosely-laid with the adhesive side facing upwards and removing the selvedge release film at the pre-manufactured overlap areas and is firmly pressed to ensure firm bonding. Seal roll end laps and non selvage joints with a special tape strip powerpruf then firmly Duct Tape a double side adhesive tape to stuck on the overlap removing granules and pressing it thoroughly by roller to release entrapped air if any. The product complies to a tensile strength of 800N, elongation of 400% and peeling strength from concrete 2.5N/mm. The rate is inclusive of all adhesives, sealants, tapes for overlap areas, labour and all jointing material with necessary tools and equipment’s for carrying out the work to the entire satisfaction of the Engineer-in-charge.

2749.06

2625599

955.09

... More
Supply and installation of 1.5 mm thick MYK Self Stick 3000 post-applied Self-adhesive Membrane with HDPE liner onto prepared and primed(MYK Tarmat SB 200) retaining wall surface with a side overlap of 75mm and end overlap of 100mm as per specification. All membrane to be terminated at least 300mm above ground level by preparing a groove and terminate the membrane inside the groove and seal the groove with polymer modified mortar

1241.64

825336

664.71

... More
Surface Preparation for podium: The substrate must be sound, free from dust dirt, oil, grease, loose particle etc. The substrate must be dry before application of MYK Coat WPU-1K . The substrate must be grinded properly to remove all the cement laitance to open the pores of concrete substrate to enhance of the bonding of the coating with concrete. Treatment of Construction joints & cracks: The entire construction joint & visible crack shall be identified thoroughly with a marker. The crack shall then be opened by a mechanical cutter in a wide of 4-5 mm with a depth of approx. 20 mm. Then the crack shall be treated with 2 component low viscous epoxy injection grout MYK Grout Inject E-200. The mixed material shall be poured in the opened crack & allow the material to penetrate in the crack to seal the crack properly. Based on the nature of the crack & porosity, the sealing activity may require more than one time. Supply & apply a primer coat of MYK Induprime EPW 44 @ 0.2 Kg/ m2 and allow it to achieve the completely dry condition. The consumption may vary depending upon substrate condition & porosity. After priming application, MYK Coat WPU-1K shall be applied over the primed surface by using brush or knap roller. The consumption shall be 3 Kg/ m2.It must be evenly to achieve an average uniform thickness.

1555.88

2295637

1475.46

... More
2.50 cm thick grading concrete (1:2:2) using sand and bajuri of approved quality including watering and curing etc complete to required level including cost, conveyance, royalties and taxes of all materials and cost , conveyance of all labour with T&P required for the work etc complete in all respects as per the direction of the Engineer in charge.

1

-

-

... More
BASEMENT FLOOR

1555.88

355985

228.8

... More
Fourth FLoor

136.11

44072

323.8

... More
NINETH FLOOR

943.81

517302

548.1

... More
TERRACE FLOOR

223.32

137338

615

... More
Providing & applying water proofing treatment (Two component glassfibre reinforced specially formulated acrylic modified cementious elastic coating system) using Sika Top seal-109 @ 2.50kg/sqm & Sika Feb-1 or equivalent (glass fibre cloth)including all cost conveyance labour T & P etc complete.

1303.24

612285

469.82

... More
Supplying, fitting and fixing of M.S grills, grill gates with top and bottom rails, steel windows, steel doors, steel frames for doors and windows ( as per I.S. specification and as per approved drawings ) in proper position in all floors and at all height including making holes to brick walls/ R.C.C structure/wood work etc. and making good to the damaged walls/ structures with cement concrete (1:2:4) with black hard crusher broken granite stone chips of 12mm to 20mm size ( 20mm size not to exceeds 25% ) including watering and curing including cost, conveyance, loading, unloading, stacking, royalties and taxes of all materials, cost of all Labour, Labour cess ,Sundries, T&P required for the work etc.complete as per the direction of Engineer in charge ( W.I. / M.S. windows grills, grill gates, collapsible gates with top and bottom rails, steel windows, steel doors, steel frames for doors and windows, staircase and parapet railings square bar along with required nos. of nails and screws and other required materials of approved quality and approved size shall be supplied by the contractor at his own cost.)

33654.46

1972151

58.6

... More
Painting with synthetic enamel paint of approved colour, shade and brand on New steel work in two or more coats as required to give an even shade including an under coat of suitable primer of approved brand and manufacturer including cost of all materials with taxes and transportation, loading, unloading, scaffolding, all labour, Labour cess, sundries, T&P, etc. complete as per the direction of the Engineer-in-charge including filling gaps with putties, scrapping, sand papering and cleaning the surface to make free from rusts, dusts and oily substances before applying primer etc. complete.

1

-

-

... More
BASEMENT FLOOR

7.42

1000

134.7

... More
GROUND FLOOR

58.11

7827

134.7

... More
FIRST FLOOR

35.4

4849

137

... More
SECOND FLOOR

60.68

8452

139.3

... More
THIRD FLOOR

32.6

4618

141.7

... More
Fourth FLoor

60.59

8737

144.2

... More
FIFTH FLOOR

32.68

4793

146.7

... More
SIXTH FLOOR

66.95

9994

149.3

... More
SEVENTH FLOOR

41.64

6329

152

... More
EIGHTH FLOOR

66

10216

154.8

... More
NINETH FLOOR

66

10401

157.6

... More
TERRACE FLOOR

35.66

5727

160.6

... More
Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontal side & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mm thick GI sheet ( Zinc coating not less than 120gm/m²) suitable for mounting 120 min Fire Rated Glazed Door Shutters. The frame shall be filled with Mineral wool Insulation having density min 96Kg/m³ . The frame will have a provision of G.I. Anchor fastners 14 nos ( 5 each on vertical style & 4 on horizontal style of size M10 x 80 ) suitable for fixing in the opening along with Factory made Template for SS Ball Bearing Hinges of Size 100x89x3mm for fixing of fire rated glazed shutter. The frame shall be finished with a approved fire resistant primer or Powder coating of not less than 30 micron in desired shade as per the directions of Engineer - in- charge . (Cost of SS ball bearing hinges is excluded).

770.7

951698

1234.85

... More
Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 min Fire Rating confirming to IS:3614 (Part II) or EN1634- 1:1999, tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mm wide and bottom rail of 110 mm x 60 mm made out of 1.6mm thick G.I. sheet (zinc coating not less than 120gm/m²) duly filled mineral wool insulation having density min 96 kg/m³ and fixing with necessary stainless steel ball bearing hinges of size 100x89x3mm of approved make, including applying a coat of approved fire resistant primer or powder coating not less than 30 micron etc all complete as per direction of Engineer-in-charge (panelling to be paid for seperately).

257.58

1761677

6839.34

... More
Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions etc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c , including applying a coat of approved fire resistant primer/powder coating of not less than 30 micron on G.I. beading, & special ceramic tape of 5 x 20 mm size etc complete in all respect as per direction of Engineer-in-charge. The glass shall be clear, toughened, interlayered, non-wired fire resistant having 11 mm thickness of approved brand with 120 minutes of fire resistance both integrity & radiation control (EW120) and minimum 15 min of insulation (EI15) and having a sound reduction of 37dB and LT of 86%. Glass shall be compliant to class 2(B)2 category of Impact Resistance as per EN 12600. The glass should be manufactured in UL & TUV audited Facility and including UL-EU Certification.The maximum glazing size cannot be more than 1100 mm x 2200 mm (w x h) or 2.42 sq mts in total area. The test report for the complete system (Glazed Door or Partition) will be considered valid only if it contains the stamp and signature of the authorized signatory from the glass manufacturer. (Actual glass size is to be measured at site for payments)

290.25

9885598

34058.91

... More
Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness .The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.

74.1

29947

404.15

... More
Providing and fixing to existing door frames. 30 mm thick Fiberglass Reinforced Plastic (F.R.P.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF)/ Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS: 14856, complete as per direction of Engineer-in-charge.

20.48

50615

2472.07

... More
Supplying & fixing in position Greenlam Sturdo Classique Versatile Toilet Cubicle with ANTI BACTERIAL PROPORTY (of following standard dimension which includes 600mm door size width) made of heat, bacteria, water, chemical, scratch impact and anti bacterial resistant 12mm thick solid compact laminate panels tested by shriram Test House. Finish of the compact laminate should be suede/ *Raw silk, which includes doors, pilasters & intermediate panels finished with approved texture/shade as per the detail drawings & as per IS 2046 (Indian Standard) and as per fire retardant BS-476/97 standard. The product should have Green Guard Certificate. This also includes providing and fixing in position necessary hardware made out of Stainless steel (Grade 304) & Aluminium powder coated top rail as per manufacturer’s specifications & Architects instructions like (1) SS Door Knob, (2) SS Gravity hinges, (3) SS Thumb turn lockset indicators, (4) Aluminum Powder Coated Top Rail, (5) SS Coat Hooks, (6) Aluminium anodised U-Channels, (7) SS Adjustable Foot, (8) Noise Deafening Tape etc. (9) Screws & wall Plugs. The top fitting should consist of Aluminium Powder Coated top rail which will get fixed with Mid & End pilasters. All other hardware & screws will of stainless steel in 304 Grade with satin finish. Top rail is extruded Aluminium will be powder coated or anodized (Grade 6063 Micron Aluminium). All pilasters are supported by stainless steel adjustable footing with non corrosive steel inserts. Toilet Cubicle with standard dimension of 1995mm Height x 1000mm Width x 1550mm Depth, which includes 600mm door size width). Toilet Cubicle I-Shape (Front Partition) with standard dimension of 1995mm Height x 1000mm Width which includes 600mm door size width). All aspects specified by the manufactures, Greenlam Sturdo Classique Versatile Model or equivalent.

60

1890000

31500

... More
Providing and fixing factory finish pre hung engineered wood complete door set with matching door frame, door and architrave. Door frame:- to be made as per available wall opening dimension at site in engineered wood laminated veneer lumber (LVL) or equivalent of density 600 kg/m3 + cross section to cover the complete jamb fixed in aperture using expandable structural PU foam with proper hold fasting through conceal anchor bolts and a provision of telescopic architrave. Door frame should have matching gasket on all side of the rebate. Door Shutter:- 36mm flush made of 50mm wide style and rail in engineered LVL wood or equivalent wood with tubular board infill of suitable thickness with 24hrs BWP HMR HDF skin on both sides with laminate / PVC / Olefin / veneer look like finish (matching to frame) with 1.5mm PVC edge band fixed with using PUR glue on all 4 sides of the door. Architraves:- both sides of door frame to have 8mm HDF telescopic architrave with finish matching to door frame. Architrave will cover gap between frame & wall and any undulation in wall. Cut out and drilling for mortise / cylindrical locks and hinges to be precisely done on CNC machines in factory. Door should pass IS 2202 specification and IS 4020 test methods. Fixing of all ironmongery with hardware fittings complete to satisfaction and approve by Competent authority.

183.55

1755756

9565.29

... More
Providing and fixing factory finish pre hung engineered wood complete door set with matching door frame, door shutter. Door frame:- to be made as per available wall opening dimension at site in engineered wood laminated veneer lumber (LVL) or equivalent of density 600 kg/m3 + cross section to cover the complete jamb fixed in aperture using expandable structural PU foam with proper hold fasting through conceal anchor bolts and a provision of telescopic architrave. Door frame should have matching gasket on all side of the rebate. Door Shutter:- 36mm flush made of 50mm wide style and rail in engineered LVL wood or equivalent wood with tubular board infill of suitable thickness with 24hrs BWP HMR HDF skin on both sides with laminate / PVC / Olefin / veneer look like finish (matching to frame) with 1.5mm PVC edge band fixed with using PUR glue on all 4 sides of the door. Cut out and drilling for mortise / cylindrical locks and hinges to be precisely done on CNC machines in factory. Door should pass IS 2202 specification and IS 4020 test methods. Fixing of all ironmongery with hardware fittings complete to satisfaction and approved by Competent authority.

179.26

1294641

7222.24

... More
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately).

170.6

760140

4455.82

... More
Providing fitting, fixing of Al. door with OEL anodized Al. door section of 9202 as vertical member, 9201 as top member and 9200 as bottom and middle member and 6mm plain glass in top portion with 12mm thick pre-laminated board in bottom portion fixed on door frame by means of tapered clip No. 4660 and the frame to be completed by means of jointing angle No. 1855 including all cost of labour, T&P, hire charges of drilling machine, labour charges etc. complete.

59.67

334599

5607.5

... More
Providing and fixing factory made uPVC white colour casement/ casement cum fixed glazed windows comprising of uPVC multichambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately) Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Casement cum fixed panel window having both end single casement panel, middle fixed panels and at top completely fixed ventilator with S.S friction hinges (350 x 19 x 1.9) made of (big series) frame 67 x 60 mm, sash 67 x 80 mm , & mullion 67 x 80 mm all having wall thickness of 2.3 ± 0.2 mm and single glazing bead/ double glazing bead of appropriate dimension . (Area of window above 3.00 sqm upto 5.00 sqm). (DSR 2016 Code no 9.147A.6)

280.8

1760739

6270.44

... More
Providing and fixing factory made uPVC white colour sliding glazed window above 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads, uPVC extruded interlocks and uPVC extruded Inline sash adaptor (if required), EPDM gasket, wool pile, zinc alloy (white powder coated) handle on one side of extreme panel along with zinc plated mild steel multi point locking having transmission gear with keeps, zinc alloy (white powder coated) touch lock with hook (if required for wire mesh panel), stainless steel (SS 304 grade) body with adjustable double nylon rollers (weight bearing capacity to be 120 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealant shall be paid separately). Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Two track four panels sliding window made of (big series) frame 67 x 50 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 4.00 sqm upto 8.00 sqm).

85.14

416589

4892.99

... More
Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealant shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Three track three panels sliding window with fly proof SS wire mesh (Two nos. glazed & one no. wire mesh panels) made of (small series) frame 92 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area of window upto 1.75 sqm).

9

67452

7494.71

... More
Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete.

365.94

1120153

3061.03

... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With plain glass panes of 5 mm thickness

9

7848

872.08

... More
Providing and fixing factory made uPVC white colour fixed glazed windows/ ventilators comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), , uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area upto 0.75 sqm.)

68.94

356241

5167.42

... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With Frosted glass panes of 4 mm thickness

68.94

59171

858.3

... More
HI-STEEL Aluminum Sun Louvers 84R system comprises of 84 mm wide and 16 mm deep roll formed out of aluminum coils. In Aluminum, Panels are made of 0.5mm thick aluminum alloy 3105/3005 and Carriers are made of 0.9mm thick aluminum alloy with cut-outs to hold panels. Aluminum panel and carrier shall be polyester powder coated with 60-70 microns. HI-STEEL Sun louver system is a vertical or horizontal wall sun shading system. The system use 84 R panels that snap into vertically mounted frames. The frames can be mounted on the exterior of a building over window openings, along balconies or over open area on a building elevation. The vertical/horizontal frames are offered in two different designs that hold the panels at different angles of 35 and 45 degrees. The ranges of angles provide air flow, sun shading, safety from rainfall and desired visibility.

39.6

101617

2566.1

... More
Providing and fixing Glass Reinforced Concrete (G.R.C) Screens in approved size, pattern, design, shadeand thickness of 50mm on frame and design element in 30mm thick have weight approximately between 3.5 – 4 Kg per Sq. Ft. and color of M/S UniStone make or equivalent. The above weight and thickness is considering dimensions of screens up to 2133mm in height and 1219mm in width and having at least 50% void space. The screens should be made from ‘53 grade’ White Portland Cement manufactured by ‘JK Cement’ or equivalent, Quartz, Fine Silica Sand, Alkali Resistant Glass Fiber manufactured by ‘N.E.G JAPAN’ or equivalent, Super Plasticizers manufactured by ‘BASF’ or equivalent, Polymers manufactured by ‘BASF’ or equivalent and U.V resistant Synthetic inorganic pigments should be used for pigmentation manufactured by ‘BAYFERROX (Germany)’ or equivalent. The material casting should take place in FRP Molds. The fixing of Screens should be ‘Dry fixing’ i.e. to be done with M.S Galvanized Clamps, fixtures and fasteners of Hilti / Fischer.

206.07

1109068

5382

... More
(Double Skin Partition)Supplying, fitting & fixing 65 – 75 mm thick full height/half height double skin partition, partly glazed, made out of 42mm x 50mm & 50mm x 50mm anodised aluminium frame at random (of variable grids ranging from 300mm x 300mm, 600mm x 600mm, 900mm x 900mm) Paneled with 6mm thick float glass ( deep itched , sides beveled by a least 50x50 mm & high polished ) of saint gobain wherever glazing required as per drawing & 6mm BWP ply on both sides fixed to frame work to make double skin & over which 1 mm laminate of approved shade fixed up to false ceiling & above ceiling wherever necessary, middle portion of partition shall be made with extra thickness with 12 mm BWP as per drg over which WB wooden bidding shall be provided as per drg finished with melamine spray , mat polished & WB wood moulding & cornice lining . , all melamine polished .The vertical members shall go beyond the ceiling level & fixed to the soffit of R.C.C. slab along with one extra top member. The bottom member & the top member shall be fixed to the RCC floor / roof slab with wedge bolt & rawl plugs at suitable intervals The visible portion of the framework shall have one coat of primer & two coats of matt finish paint of ducco. Each panel glass shall be fixed with required melamine polished(sprayed )WB beading as per detail design & at places glass panels shall be fitted with patch fittings ,silicon sealant if required. All materials are to be of approved make, shade & quality. The work shall be executed to the satisfaction of the consultant/ bank. The rate shall include all materials, labour, taxes, T& P, transportation, royalties, etc., for complete work. (Exposed surface shall be taken into measurement.) ( pl refer drg. for further details )

967.38

6183371

6391.91

... More
Space Frame: Design, Supply, installation, testing and commissioning of Space Frame with assembling and erection.Grid size: 2mtr X 2mtr with 75 die solid MS nod, MS Round Pipes (steel tube) to be used in space frame member shall be ERW medium grade pipe - ISI grade with MS high tensile hex bolt 10.9 grade , MS Base plate, High Tensile MS locknut & solid MS Probe, MS Column, and all MS member are painted with one coat of enamel primer & two coat of Enamel paintand top cladded with 10mm Thick multiwall Polycarbonate sheet with 50mm Aluminum Top and Bottom section with EPDM Gasket, Self-Taping Screw, as per requirement.

254.92

1920818

7534.98

... More
Providing fitting and fixing up partition walling OEL aluminum anodized section No.9210 and 9207 as single groove and double groove respectively as horizontal and vertical member and OEL section 4660 as Tapered clip for fixing up 12mm thick pre laminated board (Nova pan Make) and jointing angle No. 1855 with 6mm thk plain glass etc.

497.53

1392140

2798.1

... More
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).

5191.01

1614404

311

... More
Providing & fixing 12mm thk tougnened glass railing of 1m height with 50mm dia SS rail mounted inside for safety & vertical SS supports up to 25mm X50mm with minimun 2mm thickness fixed to the floor using adequate number of screws as per the approved drawing including cost, conveyance of all materials & cost of labour, T&P etc as required for the work complete as per the direction of the Engineer-in-charge (GLASS RAILING)

263.12

1117444

4246.9

... More
EXPANSION JOINT: I) Prepare the joints maintaining depth to width ratio as 1:2 or as recommended by the site in charge. Minimum width to depth ratio shall be maintained and in any case it shall not be less than ii)Providing and laying of MYK Flexi joint tape of 300 mm wide with MYK Indubond VK 4031 (I).

39.55

50981

1289.05

... More
Providing and fixing sheet covering over expansion joints with iron screws as per design. Aluminium fluted strips 3.15 mm thick. 200 mm wide

39.55

17308

437.63

... More
Providing and fixing polystyrene backer rod in the expansion joint leaving required depth from the top to fill the sealant. The backer rod shall be installed in such a way that, the depth shall be equal to the width, if the width of the joint is lesser equal to 10mm, and for width of the joint above 10mm, depth shall be maintained half of its width.Apply a coat of epoxy as a moisture barrier and install polysulfied sealant in the expansion joints .Allow it to dry it completely. Apply a belting of FASCRSEA immediately after diluted version of Hi seal slurry primer coat. Apply the first coat over the primed surface. Install the sealing tape 29200 on wet surface of Water guard ensuring the sealing tape is completely embedded in the coat of water guard and allowed to dry (4 hours), apply the second coat of Water guard in opposite direction to the first coat and allow it to dry completely.Protection plaster is recommended at additional cost.

39.55

1779

45

... More
Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. (The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).

5213.78

1763561

338.25

... More
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)- cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including: Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment , including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass. Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge. Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this sub- head. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves ) on the external face shall be measured in sqm. up to two decimal places. "Note:- 2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NBL Certified laboratories " "(1) Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr " (2) Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing method for a range up to 2000 ml. "(3) Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml " "(4) Structural Performance Deflection and deformation by static air pressure test (1.5 times desing wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm " "(5) Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test. Tests to be conducted on site. " (6) Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000 ml

1520.23

3663602

2409.9

... More
Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor.“(Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.26.2)“For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm.“(DSR 2016 Code no 25.3) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.

667.45

2490038

3730.7

... More
Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc. ,all complete for the required performances as specified, as per the Architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer- in- Charge.“For payment, only the actual area of glass on face # 1 of the glass panels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. (Payment for fixing of Spandrel Glass Panels in the curtain glazing is included in cost of relevent Item*). (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.

624.75

1748487

2798.7

... More
Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer- in-Charge.

228.03

670790

2941.62

... More
Spider Glazing:Design, Supply, installation, testing and commissioning of Spider Glazing system with using 12mm cleared toughened glass with necessary one way, two way& four way spider fitting with 19mm thick cleared glass for vertical fin with SS splice plate for glass support. In bottom using Aluminum U channel for vertical glass support & SS Brackets, SS Nut bolts etc. & Dow Corning silicon sealant shall be used for glass joint.

440.63

5003869

11356.3

... More
Design, Supply, installation, testing and commissioning in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places."

440.8

1501325

3405.91

... More
Paneling to Hall & rooms where ever shown in drawings by fixing 6mm BWP ply to the frames made out of 40mm x20mm. GI frame by means of nailing or screwing over with 1 mm tk laminate fixed by means of adhesive having grooves & necessary white beach wood beading , finished with hard wood moulding & cornice lining all ducco mat spray painted, as per direction of EIC . The cost includes all the materials, labour, transportation taxes etc., complete for the work with 40 mm tk rock wool backing.(wooden panelling)

360.86

1623847

4500

... More
Single Layer Wall lining with 12.5mm thick USGBORAL EchoBloc Gypsum plasterboards Supplying and Fixing of USGBORAL Wall lining system components. This includes USGBORAL Ultraframe Perimeter Channel (0.55mm thick having one flange of 28mm and another flange of 18mm and a web of 30mm) screw fixed to floor and ceiling with the help of approved screws and fasteners at 600mm centers with first & last fixing point at not greater than 50 mm from either end.G.I. Perforated wall bracket shall be screw fixed on to masonry substrate using appropriate fixings spaced at 800mm vertical centers and 610mm horizontal centers. Universal Section (having both flanges 27mm, web 45mm, lip 6mm thickness 0.55mm) are spaced at 610mm centers at not more than 610mm centers screw fixed to perimeter and wall bracket using corrosion resistant 13mm Wafer Head Self Tapping screw. 12.5mm thick USGBORAL EchoBloc C10N8 gypsum plasterboards is screw fixed with 25mm long Drywall screws at 230 mm centers. The screw fixing of standard gypsum plasterboards to the metal framing at the periphery, openings and cut edges should be at 150mm centers. All joints to be taped & finished with USGBORAL Paper tape & All Purpose Joint Compound confirming to ASTM C475. (Acousic Wall Panelling)

117.54

235080

2000

... More
PROVIDING AND FXING OF 6mm thickness of HPL (high pressure laminate ) board of royal touch or compact king brand. HPL boards shall be fire resistant, UV resistant, moisture resistant and the manufacturer should give minimum 10 years warrantee. HPL wall cladding can be installed by using essential fasteners of non corrosive material over aluminum ,head of the rivets are color with powder coated so as to compliment the royal touch or compact king external wall cladding range and are UV coated for better color fastening properties. Aluminum cube channel should be of 50*25*2mm thick, every junction of two panel’s aluminum cube channel should be 50*25*2mm thick. Riveting distance between each rivet in horizontal/vertical 450mm-600mm c/c in elevation, Hpl wall cladding groove or gap between each panel in horizontal & vertical should be 6mm-8mm including cost, conveyance of all materials & cost of labour, T&P etc as required for the work complete as per the direction of the Engineer-in-charge.

600.86

2909364

4842

... More
Suspended false ceiling with ST 50(Single Layer Boarding with 12.5mm thick USGBORAL MoistBloc gypsum plasterboards) Supplying and Fixing of USGBORAL Suspended ceiling system components. This includes USGBORAL Perimeter Channel ST50 (0.50mm thick having one flange of 21mm and another flange of 28mm and a web of 25mm) screw fixed to brick wall/partition with the help of approved screws at 600mm centers. Then suspending USGBORAL ST.50 Intermediate channel (45mm x 0.9mm thick with two flanges of 14mm each) from the soffit at 1220mm centers with USGBORAL ST.50 Ceiling Angle (25x10mmx0.50mm thick) fixed to RCC Slab with USGBORAL ST.50 Soffit Cleat and Approved Fasteners @ 600mm Centers respectively. USGBORAL ST.50 Ceiling Section (having knurled web of 48mm and two flanges of 24mm each) are then fixed to the USGBORAL ST.50 Intermediate channel with the help of connecting clip (2.5mm Dia) and in perpendicular direction to the intermediate channel at 457mm centers. 12.5mm thick USGBORAL MoistBloc gypsum plasterboards is screw fixed with 25mm long Drywall screws at 230 mm centers. The screw fixing of gypsum boards to the metal framing at the periphery, openings and cut edges should be at 150mm centers. All the Moistbloc Gypsum plasterboards must be staggered.All joints to be taped & finished with USGBORAL Paper tape & All Purpose Joint Compound confirming to ASTM C475.

2377.07

2044279

860

... More
16mm thick USGBORAL Radar™ ClimaPlus™ Tile with Micro Line Grid 15mm Supplying and Fixing of USGBORAL Suspended ceiling system components. This includes Micro Line black reveal T grid Wall angle of 19mmx15mm shall be screw fixed to brick wall/partition with the help of approved screws at 600mm centers. Then suspending Micro Line black reveal T Main T grid of 15mm x 35mm of length 3600mm from RCC Slab. The Main T is hung with USGBORAL adjustable level clips & 4mm diameter GI rod which are connected to Soffit Cleat and Approved Fasteners @1200mm centers or as approved. The Cross T of 15mm x 35mm of 1200mm length shall be interlocked between main T Grid at 600mm centers to form 1200 x 600mm modules. 600 x 600mm modules to be formed by click fitting Cross T of 15mm x 35mm of 600mm length centrally between the 1200mm cross T’s. Then 16mm thick USGBORAL Radar™ ClimaPlus™ ceiling panel having FLB edge of size 595x595 shall be placed into the above grid of size 600x600mm. This ceiling panel confirms to ASTM E84 surface burning characteristics. (Class A, Flame Spread: 25 & Smoke developed: 50) .The Ceiling panel provides NRC 0.60, CAC minimum: 33.Light Reflectance: 0.84, Thermal Resistance: R-1.7 & can withstand Realtive Humidity up to RH 99% (limiting conditions –Max 490 C /99%RH).The front & back side of the tile has anti-Microbial coating.

3640.11

4004122

1100

... More
18mm thick USGBORAL Skyrock Nordic 0.9 NRC Tiles™ Tile with Micro Line Grid 15mm (Acoustic ) Supplying and Fixing of USGBORAL Suspended ceiling system components. This includes Micro Line black reveal T grid Wall angle of 19mmx15mm shall be screw fixed to brick wall/partition with the help of approved screws at 600mm centers. Then suspending Micro Line black reveal T Main T grid of 15mm x 35mm of length 3600mm from RCC Slab. The Main T is hung with USGBORAL adjustable level clips & 4mm diameter GI rod which are connected to Soffit Cleat and Approved Fasteners @1200mm centers or as approved. The Cross T of 15mm x 35mm of 1200mm length shall be interlocked between main T Grid at 600mm centers to form 1200 x 600mm modules. 600 x 600mm modules to be formed by click fitting Cross T of 15mm x 35mm of 600mm length centrally between the 1200mm cross T’s. Then 18mm thick USGBORAL Skyrock Nordic 0.9 NRC Tiles ceiling panel having FLB edge of size 595x595 shall be placed into the above grid of size 600x600mm. This ceiling panel of NRC 0.9.

543.41

978145

1800

... More
Providing and fixing non load bearing fixed frame for fire resistant glazed Partition for 120 min Fire Rating, made out to a profile of dimension 60mm x 70 mm of 1.6 mm thick galvanised steel sheet as per test evidence suitable for fixing fire rated glass for 120 min of both integrity & radiation control (EW120) & minimum 15 min of insulation (EI15).The profile has to be fixed to the supporting construction by means of anchor fasteners of size M10 x 80, every 150 mm from the edges and every 500 mm (approx) c/c. Linear meaurement of frame shall be measured for payment. The frame shall be filled with mineral wool insulation of density min 96kg/ m³. and finished with a approved fire resistant primer or Powder coating of not less than 30 micron in desired shade as per the directions of Engineer - in- charge .

75.9

93725

1234.85

... More
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : A)First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. B) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.

385.8

84007

217.75

... More
Supply of all materials, labour, T & P & filling sunken floor of toilet block with approved quality under size 40 mm to 50 mm cinder mixing with cement slurry for farm binding etc . all complete as the EIC.

115.74

217591

1880

... More
Providing and laying in situ five course water proofing treatment with APP (Atactic Polypropylene) modified Polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40Kg per sqm, 2nd & 4th courses of bonding material @ 1.20 kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to IS : 702, 3rd layer of roofing membrane APP modified Polymeric membrane 2.0 mm thick of 3.00 Kg/ sqm weight consisting of five layers prefabricated with centre core as 100 micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron HMHDPE film. 5th, the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat (item of laying brick tiles shall be paid for separately).

1303.24

387973

297.7

... More
Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) 78, solar reflection 0.70 and initial emittance 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner.

1079.92

1128160

1044.67

... More
Providing and laying water proofing treatment in sunken portion: The surface should be clean, sound and free from loose cement particles, laitance, oil or grease before commencing application. The cleaning should be done with wire brushing, scrubbing, chipping etc. followed by water washing. The surface defects like potholes, crack, void etc. should be filled with suitable repair motor Apply a solvent free polymer dispersion primer AquaArmUniPrimer-GE which will enhance bonding and load bearing capacity and also harden the surface. It is ready to use and applied with paint brush @ 0.2 kg/sqm. After the prime coat is dried out apply AquaArmSaniflex an elastomeric, single component, liquid applied, seamless, breathable, synthetic rubber based waterproofing system. The coating should be carried out in cross direction in two coats and consumption @ 1.2 kg/sqm. Prior to the application of AquaArmSaniflex it is recommended that all the construction joints, Wall/floor joints, pipe inlets and outlets are treated with the methodology suggested by MYK Schomburg BOQ for that area.

385.8

226464

587

1

-

-

... More
Internal Water Supply & Sanitary Installations :-Providing all materials, labour, T&P for laying/fixing of following dia CPVC pipes SDR-11 as per IS-15778/2007 with ISI mark including fixing of required size CPVC fittings like bend, Tee, elbow, offsets etc. and the same fixed on wall or floor with holder bat clamps screw in all floor or laying in trenches including excavation of earth work in all kinds of soil & backfilling the trenches as per specification & testing the joints with required water presure.The cost inclusive of all taxes,duties,transportation scaffolding etc. as per specification and direction of Engineer-in-charge. Make:ASTRAL/ASHRIVAD/AJAY.

1

-

-

... More
20mm dia

139

35445

255

... More
25mm dia

407

138787

341

... More
32mm dia

380

189240

498

... More
40mm dia

222

149628

674

... More
50mm dia

285

295545

1037

... More
Providing all materials, labour, T&P for laying/ fixing of following dia CPVC pipes Sch-80 as per ASTM-F-441 including fixing of required size CPVC fittings like bend, Tee, elbow, offsets etc. and the same fixed on wall or floor with holder bat clamps screw in all floors or laying in trenches including excavation of earth work in all kinds of soil & backfilling the trenches as per specification & testing the joints with required water presure.The cost inclusive of all taxes, duties, transportation, scaffolding etc. as per specification and direction of Engineer-in-charge. Make:ASTRAL/ASHRIVAD/AJAY.

1

-

-

... More
65mm dia

161

370944

2304

... More
80mm dia

5

15345

3069

... More
100mm dia

126

569016

4516

... More
Providing all materials, labour, T&P for laying/ fixing of following dia uPVC solvent welded pipes Sch-80 as per ASTM-D-1785 including fixing of required size uPVC Schedule-80 fittings as per ASTM D-2467 like bend, Tee, elbow, offsets etc. and the same fixed on wall or floor with holder bat clamps screw in all floors or laying in trenches including excavation of earth work in all kinds of soil & backfilling the trenches as per specification & testing the joints with required water presure.The cost inclusive of all taxes, duties, transportation, scaffolding etc. as per specification and direction of Engineer-in-charge. Make:ASTRAL/ASHIRVAD/AJAY/SUPREME

1

-

-

... More
80mm dia

245

225155

919

... More
Providing all materials, labour, T&P for laying/fixing of following dia uPVC pipes as per IS-13592:2000 with ISI mark of Type-B (1.7-2.1 kgf/cm2 & class-3) including fixing of required size uPVC fittings like,bend,Tee,elbow,offsets,etc. and the same fixed on wall or floor with holder bat clamps screw in all floors or laying in trenches including excavation of earth work in all kinds of soil & backfilling the trenches as per specification & testing the joints with required water presure.The cost inclusive of all taxes, duties, transportation, scaffolding etc. as per specification and direction of Engineer-in-charge. (As per Cat no.2169212 of Ashirvad pipes HSN Code:3917)

1

-

-

... More
50mm dia

42

9954

237

... More
Providing all materials, labour, T&P for fitting & fixing of following Bronze Ball Valves confirming to IS-778 with ISI mark in all floor & fixing with the pipes after cutting the pipes to required shape & size including wastage etc. of following nominal diameter, all complete including testing the joints with required water pressure.The cost inclusive of all taxes,duties,transportation scaffolding etc. all complete as per specification and direction of Engineer-in-charge. Make:ZOLOTO. (As per Art no.1008 & HSN Code-84812000 of ZOLOTO)

1

-

-

... More
25mm dia Bronze ball valve

80

112960

1412

... More
32mm dia Bronze ball valve

80

218800

2735

... More
50mm dia Bronze ball valve

8

48432

6054

... More
65mm dia Bronze ball valve

8

82472

10309

... More
80mm dia Bronze ball valve

2

29852

14926

... More
100mm dia Bronze ball valve

2

47946

23973

... More
Providing all materials labour, T&P for making grooves in bricks/stone masonary walls vertically or horizontally up to required depth and width in all floor for laying of pipes and fittings up to 50mm dia, testing the joints with required water pressure and making good the damages with cement concrete 1:2:4 with 12mm size h.g.c.b.chips and finished smooth with cement morter (1:4) to original shape including cost of materials, curing, conveyance, taxes of all materials etc. all complete as per specification & direction of EIC.

674

95708

142

... More
Providing all labour,T&P for cutting holes in bricks or stone masonry wall for taking pipes in all floors and making good the damages with cement concrete 1:2:4 finished smooth with CP 1:4 to original shape including cost of all materials, curing, conveyance, taxes, duties etc. all complete as per specification & direction of Engineer-in-charge.

1

-

-

... More
For 15mm to 50mm dia pipe to pass in 125mm to 250mm thick wall

161

5635

35

... More
For 75mm to 150mm dia pipe to pass in 250mm thick wall

107

17334

162

... More
Providing all labour,T&P and cutting holes in RCC chajja/roof/floor for taking pipes through and making good the damages with supply of all required materials etc. complete as per the direction of the Engineer-in-charge.

146

19710

135

... More
Providing all materials, labour, T&P for fitting and fixing white glazed vitreous china Wall mounted water closet Rimless (European pattern) with seat cover (solid) of approved make in all floor including supply of sutaible bracket, PVC wall plug and Brass screws etc. all complete including cost, taxes and conveyance as per specification all complete as per direction of Engineer-in-charge. Make:HINDWARE/PARRYWARE/CERA. (As per Cat no.92523 of Hindware)

1

-

-

... More
European water closet

80

1348640

16858

... More
Providing all materials, labour, T&P for fitting and fixing of 32mm size Flush Valve with elbow set & Wall flanges of approved make in all floor including supply of sutaible bracket, PVC wall plug and Brass screws etc. all complete including cost, taxes and conveyance as per specification all complete as per direction of Engineer-in-charge. Make:JAQUAR/PARRYWARE/CERA. (As per Cat no. FLV-CHR-1015 of Jaquar)

1

-

-

... More
Flush Valve .

80

331920

4149

... More
Supply all materials and labour for fitting and fixing of following size white glazed vitreous china Under Counter wash hand basin of approved make in all floor of approved quality including cutting the walls & floor and making good the damages with cement concrete etc. including all taxes, duties, transportation etc. all complete as per direction of EIC. (Make:HINDWARE/PARRYWARE/CERA) (As per Cat no. 10095 of Hindware)

1

-

-

... More
Under Counter Wash Hand Basin .

61

284260

4660

... More
Supplying all materials, labour & T&P for fitting and fixing of following sizes of white glazed vitreous china flat back half stall urinal basin confirming to specification of approved make as per IS-2556 with ISI mark in all floor along with supply & fixing of necessary component parts like pair of C.I./M.S. bracket including connection from water supply pipe with all taxes, duties, transportation etc. all complete as per specification & direction of the Engineer-in-charge. (Make:HINDWARE/PARRYWARE/CERA) (As per Cat no. 60002 of Hindware )

1

-

-

... More
Flat back half stall urinal .

50

248850

4977

... More
Providing all materials, labour, T&P for fitting and fixing of white glazed vitreous china water closet (European pattern) 'P' or 'S' type with cistern & seat cover, wash hand basin of size 650mmx350mm with one pair basin bolt, one no. hinged rail 760mm long & 5 nos. grab rails 600mm long including supply of sutaible PVC wall plug and Brass screws etc. suitable for handicapped toilets in all floor etc. all complete including cost, taxes and conveyance as per specification all complete as per direction of Engineer-in-charge. (Make:HINDWARE/CERA) ( As Per Cat no. 70002 matrix Set of Hindware)

1

-

-

... More
Handicapped Toilet with all acessories

10

643320

64332

... More
Providing all materials, labour, T&P for fixing of following sizes of Prime mirror (60x45 cm)of 6mm thick mounted on 6mm thick AC back sheet & CP cup screw with PVC wall plugs in all floor including cost, conveyance, taxes of all materials complete as per specification and direction of E.I.C.

1

-

-

... More
Prime mirror (As per cat no.C862899 of Cera)

61

159820

2620

... More
Providing all materials, labour,T&P ,fittings and fixing of different water supply (CP on Brass) fitting (Quarter Turn or as specified) as per IS specification & approved make in all floor of following sizes and specification with leak proof threaded joints with thread seal tape or any other method as required and directed including all taxes, duties, transportation etc., testing and rectification of defects after testing complete as per direction of Engineer-in-charge.

1

-

-

... More
15mm dia Angle Stop cock with Wall Flange. (As per Cat no.FLR-CHR-5053N of Jaquar)

91

90090

990

... More
15mm dia Prissmatic Pillar Cock (As per Cat no.PRS-CHR-031 of Jaquar)

61

107604

1764

... More
C.P. Soap Dispenser with Glass Bottle (As per Cat no.ACN-CHR-1135N of Jaquar)

61

71492

1172

... More
Health Faucet ABS SS braided hose 1.00m with CP hook. (As per Cat no.ALD-CHR-585 of Jaquar)

80

89840

1123

... More
32mm dia C.P.waste 130 mm ht. (Half Threaded) (As per Cat no.ALD-CHR-709L130 of Jaquar)

61

27999

459

... More
32mm dia C.P. Waste 130 mm ht. (Full Threaded) (As per Cat no.ALD-CHR-705L130 of Jaquar)

50

22950

459

... More
150x150 mm dia stainless steel grating (As per Cat no. FT-77 square of Prayag)

244

92964

381

... More
15mmx25mm C.P. Extension piece (As per Cat no. F8070301 of Cera)

185

22385

121

... More
32 mm CP on Brass Bottle Trap. (As per Cat no.ALD-CHR-769L250x190 of Jaquar)

123

153750

1250

... More
600 mm long Braided Hose Connection Pipe.( As per Cat no.324-H of Prayag)

91

15743

173

... More
Auto-closing concealed Urinal Flush Valve. (As per Cat no.ACN-CHR-1151Nof Jaquar)

50

98200

1964

... More
Towel Ring with round Flange. (As per Cat no.ACN-CHR-1121 BN of Jaquar)

80

66560

832

... More
32 mm CP Double Coat Hook. (As per Cat no.ACN-CHR-1161N of Jaquar)

80

37040

463

... More
Two-way Bibcock with wall Flange. (As per Cat no.FLR-5041N of Jaquar)

80

117840

1473

... More
Short-Body Bib cock with wall Flange. (As per Cat no.FLR-5047N of Jaquar)

2

2306

1153

... More
Sink cock with Regular Swinging Spoutwall Flange. (As per Cat no.FLR-5357N of Jaquar)

12

19752

1646

... More
Providing, laying and jointing Centrifugally cast (spun) iron hubless soil, waste and vent pipes under floor /suspended under ceiling / fixed on the wall face conforming to IS:15905-2011 , ISO-6594. Includes making connection with sanitary fittings, and testing of pipelines, etc. all complete . (As per Jayaswal Neco Pricelist)

1

-

-

... More
100mm dia pipe

961

1117643

1163

... More
Providing, laying and jointing sand centrifugally cast (Spun) ironhubless soil, waste and vent pipes under floor /suspended under ceiling / fixed on the wall face conforming to IS:15905-2011 , ISO-6594 Includes necessary fittings like (plain or door)tees, bends, collars, crosses reducers, Y, etc, of approved make, drip seal joint, suspended under ceiling / embedded in floor. Includes making connection with sanitary fittings,of approved make etc all complete . (As per Jayaswal Neco Pricelist)

1

-

-

... More
100 mm Shielded (SS - 304) Coupling

320

149120

466

... More
100mmx100mm 'P' Trap (Hubless)

312

403104

1292

... More
100mm Plain bend

131

110040

840

... More
100 mm Plain Bend 45o

220

159720

726

... More
100 mm Door Bend

186

156798

843

... More
100 mm Single Branch Door Tee

82

98646

1203

... More
100 mm Single Branch Plain Tee 88 D

105

111195

1059

... More
100 mm single Branch Plain "Y" 450

121

128139

1059

... More
100mm Single Branch Door 'Y' 450

160

223840

1399

... More
100 mm Offset Bend (65 mm)

227

225638

994

... More
100 mm Offset (130 mm)

214

243318

1137

... More
100 mm Vent Cowl

16

14192

887

... More
100 mm Pipe MS Clamp

801

479799

599

... More
100 mm WC Connector 350 mm long with EPDM Rubber.

82

95366

1163

... More
100 mm End plug

84

36372

433

... More
Providing all materials, labour, T&P for fitting and fixing of following size of 18 mm thick Granite tile for urinal partition of approved make in all floor with edge moulding & polishing with 90o to wall between two urinals from floor level to 1.4 mtr height etc. all complete as per specification & direction of Engineer-in-charge. (Make:Black Granite Granite Tile for Urinal Partition size (1400 mm x 650 mm)

142

397855

2801.8

... More
Providing all materials, labour, T&P for fitting and fixing of following size of Trion Elegance 36 inchx20 inch Kitchen Sink etc. all complete as per specification & direction of Engineer-in-charge. (Make:NIRALI)

12

182472

15206

... More
Providing all materials, labour, T&P for fitting and fixing of following size of 18mm thick Granite tile for under counter top Wash basin approved make in all floor with edge moulding & polishing from floor level to 0.8 mtr height ,600 mm width etc. all complete as per specification & direction of Engineer-in-charge. Granite Slab for Under Counter Top Wash Basin

178

864190

4855

... More
Supply, installation,testing & commisioning of water cooler cum purifier with chiller in floor of following capacity:60/80 SS including fixing the same on the floor with necessary water connection & waste waste arrengments with all labour, T&P etc.all complete as per the specification & direction of EIC. (As per Model :AG Green pure Chill 80SS of Aquaguard) Aquaguard Green storage cooler-cum-purifier

10

487830

48783

... More
Providing all material, labour, T&P and construction of Gully Trap chamber of size as mentioned below with 250mm nominal size flyash Brick having crushing strength not less than 75kg/sqcm in CM 1:4 over a bed of 100mm thick C.C. (1:3:6) using 40mm size HG metal, plastering with 12mm thick cement plaster with cement punning in cement mortar 1:4 on inner surface and 12mm thick cement plaster in cement mortar (1:4) on external surface,fitting & fixing of 110mm square PVC Gully Trap with grating and pre-cast factory made (SFRC) cover with frame of opening size 260mmx260mm, moulding and shaping the channel & benching with C.C (1:2:4) with hard granite chips 12mm size,earth work excavation in all kinds of soil & rock and filling the cavity of the chamber with excavated & selected earth levelling the surface around the chamber with disposal of surplus earth within 50mt lead as per specification, design & drawing including cost of curing and all taxes, royality, cost, conveyance etc. all complete as per specification & direction of EIC.

1

-

-

... More
300mm x 300mm x upto 450mm deep gully trap.

8

12288

1536

... More
Providing all materials, labour T&P for construction of inspection chamber with Fly Ash bricks of size 25cm x 12cm x 8cm having crushing strength not less than 75Kg/Sqcm in C.M (1:4), PCC 1:3:6 with 40mm size hard granite crusher broken metal of 150mm thick, 12mm thick cement plaster 1:3 both in outer & inner surface of the wall & bottom, earth work excavation in all kinds of soil/rock including back filling with selected excavated earth duly watered & rammed. RCC M-20 with 20mm & down size H.G crusher broken chips having minimum cube strength 200Kg/Sqcm at 28 days confirming to IS-453/76 & IS-3370 for roof slab of 125mm average thick with form work as per the requied size including cost for MS reinforcement as per approved design & drawing & fixing of cI made manhole cover with frame (medium duty) for opening of 500mm including cost of all materials, labour, T&P etc. complete as per specification & direction of Engineer-in-charge.

1

-

-

... More
Inner size 750mm x 750mm x 500mm depth

21

159705

7605

... More
Supplying all materials, labour, T&P, fitting and fixing uPVC SWR pipes (Type-B) of approved make confirming to IS-13592/1992.with ISI Mark in all floor.

1

-

-

... More
110mm dia pipe.(Make:Astral/Ashirvad/Ajay)

426

270510

635

... More
125 mm dia (Grating)(As per Cat No. FT-64 of Prayag)

11

2145

195

... More
110mmx87.5º door bend. (Make:Astral/Ashirvad/Ajay)

33

8085

245

... More
PVC Clamp Suitable for 110mm dia pipe. (Make:Astral/Ashirvad/Ajay)

284

23856

84

... More
150 mm RCC NP2 Pipe inspection chamber to recharge pit & to Rain water Harvesting Structure.(As per Balaji Spun Pipes)

123

65559

533

... More
Supplying,of all materials,labour and T&P for Fixing Anchor Bolt and Anchor Rod and Ring over ceiling of each roof for hanging 110mm dia SWR pipes and its fittings for soil & waste water pipe etc. All complete as per gradation of EIC.

1

-

-

... More
Flush Anchor HKV M12X50,Length 50mm

440

589600

1340

... More
Providing all labour, T&P and machinaries for installation,commissioning of Three phase sensor with level indicator and cables etc as per direction of EIC.

1

-

-

... More
For Raw Water UGR (Fire-Fighting,Drinking & Flushing)

2

13960

6980

... More
For Over Head Tank of Drinking,Flushing and Fire Fighting

2

13960

6980

... More
Providing all materials,labour,T&P for construction of Cement Concrete (1:2:4) Pedestal with 12mm size h.g.c.b. chips as per approved design & drawing for CPVC 50 mm id pipe& upvc sch-80 80mm id pipe over terrace floor. The cost inclusive of all taxes, royality, hire & running charges of all machineries, Transportation charges with all consumables etc. all complete as per specification & direction of EIC.

1

-

-

... More
For 100mm id dia pipe

84

14196

169

... More
Sinking of 200mm x 150mm Dia Production Well:- Labour for drilling a perfectly vertical bore hole for a specified dia for a specified depth below G.L through consolidated and un-consolidated rocks with down the hole hammer drilling rig or combination drilling rig (1200 cfm/ 300 psi) as required to suit the site condition as per the direction of EIC including use of own rigs with its accessories, T&P & consumables etc. for lowering of 200mm dia PVC/GI pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation (GI/ PVC casing pipes, if required to prevent collapse of over burden is to be provided by the contractor including lowering and withdrawing after completion of the Tube Well).

1

-

-

... More
Labour for drilling of 200mm dia & 150mm dia bore from '0' mtr. to '100' mtr.

200

147900

739.5

... More
Providing & lowering the following size PVC pipes (ASTM) with or without slotted pipes as per the necessity from 1.00m above ground level up to required depth and fitting and fixing up in perfectly vertical position, including cutting, threading pipe and slotted pipe and supplying and fixing all jointing materials, T&P etc. complete and keeping the top of the casing pipe threaded including plugging the tube well to prevent entry of foreign materials from above. The cost inclusive of pipes, fittings, labour, consumables, POL, consumables with hire & running charges of machinaries etc. as per specification & direction of EIC.

1

-

-

... More
Lowering of 200mm (8'') dia PVC plastic pipes Sch-80 as per ASTM-D-1785/2004 upto required depth.

102

142086

1393

... More
Cleaning and developing the tube well using their own compressor continuously worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment , labour, all consumables, running & hire charges of machinaries etc. all complete as per the direction of the EIC.

2

11926

5963.2

... More
Supplying all materials, labour & tools and plant and grouting with cement slurry for sanitary sealing around the GI/PVC casing pipe up to 3mtrs below ground level to plug the bore hole including cost of cement all complete as per specification & direction of the Engineer-in-Charge.

20

7288

364.4

... More
Providing all materials required for construction of brick masonry chamber for encasing the production well with Fly Ash bricks of size 25cm x 12cm x 8cm having crushing strength not less than 75Kg/Sqcm in C.M (1:4), PCC 1:3:6 with 40mm size hard granite crusher broken metal of 150mm thick on base & 100mm thick on top of the chamber, encasing the annular area of casing pipe with cement concrete 1:2:4 of minimum size 450mmx450mmx1200mm height including form work, filling the inside cavity with sand, C.C. 1:2:4 on top of the chamber of 50mm thick, 12mm thick cement plaster 1:4 on outer wall & top surface, earth work excavation in all kinds of soil/rock including back filling with selected excavated earth duly watered & rammed with smooth finishing. The height of chamber should be 450mm from G.L. The cost inclusive of all materials, labour, T&P etc. complete as per specification & direction of Engineer-in-charge.

1

-

-

... More
Outer size 1400mm x 1400mm x 1200mm ht. chambers

2

22308

11154

... More
Installation of Submersible Pump set:-Supply, Installation, testing & commissioning of 3-phase, 50Hz Submersible pump set of required head 60 mtr & discharge 6 Lps including HDPE delivery pipes of 10 Kgf/cm2 of material grade P.E.-80, Suitable size of Four core flat cable of 143 mtr with Bore bunched copper conductor insulated sheathed with PVC for Submersible Motor with voltage grade up to 415 Volt ,5.6 KW and 7.5 Hp confirming to IS-694/1990 of required length, control panel Star Delta with APFC and ATS arrangement & required accessories suitable for 200x150mm size Production Well etc. all complete as per specification & direction of EIC. control panel with Sensor arrangement to run the motor automatically according to Level of Raw Water Sump i.e 50% of Volume& required accessories suitable for 200x150mm size Production Well.

2

317079

158539.65

... More
Installation of Centrifugal Pump set for Drinking & Flushing:- Supply, installation, testing & commissioning of Centrifugal Pump set (monobloc/End casing). The capacity of each pump, Total Head-50.00m, Discharge-11 m3/hr. with 3-phase 50Hz, 2 Hp,TEFC induction motor coupled with a common base with electrical control panel star delta with APFC and ATS arrangement suitable for the pump set, including construction of concrete foundation, suction & delivery piping arrangements, fixing of required sizes & nos.of C.I/Brass horizontal Check valves (pressure ratting PN-1.0) like Brass Full way Valve foot valve with strainer etc with sensor arrangement for filling of OH Tank flushing automatically. all complete as per the technical specification & direction of EIC.

1

-

-

... More
2(Two) set i.e. 1 (one) working & 1 (one) standby

2

117922

58961

... More
Supply, installation, testing & commissioning of Centrifugal Pump set (monobloc). The capacity of each pump, Total Head-50.00m, Discharge-18 m3/hr. with 3-phase 50Hz, 3 Hp,TEFC induction motor coupled with a common base with electrical control panel star delta with APFC and ATS arrangement suitable for the pump set, including construction of concrete foundation, suction & delivery piping arrangements, fixing of required sizes & nos.of C.I/Brass horizontal Check valves (pressure ratting PN-1.0) like Brass Full way Valve foot valve with strainer etc with sensor arrangement for filling of OH Tank Drinking automatically. all complete as per the technical specification & direction of EIC.

1

-

-

... More
2(Two) set i.e. 1 (one) working & 1 (one) standby

2

160292

80146

... More
Installation of Basement Drain Electric Pump set :- Design, Supply, Installation, testing & commissioning and obtaining statutory approval of 3-phase, 50Hz Submersible electric pump set for drainage of Dirty water from Basement Drain of capacity 5 m3/hr required head 11 mtr ,pumpset model DOMO 15,Discharge Nozzle 40 mm,solid handling 50mm,pump casing CI,Impeller CI,Shaft SS,Rating 415V ,3Ǿ,50 Hz,Power rating 1.5 HP,Type of Starter DOL with delivery piping arrangement etc all complete as per direction of EIC.( 2w+2s)

2

100000

50000

... More
Construction of Terrace Tank:- Fire-Fighting OHT-3.6x4.3x1.95 Mtr Domestic OHT-2.5x4.0x1.95 Mt Flushing/Grey OHT-2.5x3.0x1.95 Mtr

1

-

-

... More
Providing, lifting, hoisting and laying in position machine batched , machine mixed and machine vibrated design mix cement concrete of M-25 including the cost of Centering and Shuttering (minimum cement content not less than 403 Kg/Cum) grade in reinforced cement concrete structural elements using black hard crusher broken granite chips of approved quality from approved quarry including mixing and compacting to proper shape and size, level and plumbs and finishing the exposed surfaces smooth including the cost of all materials, cost of labour, conveyance, taxes, loading, unloading, royalties, watering and curing for the required period, T&P , hire & running charges of concrete mixer and vibrator, cost of Admixtures in recommended proportions ( as per IS 9103 ) to accelerate, retard setting of concrete, improve workability without impairing strength and durability etc. complete as per the direction of the Engineer-in-charge but excluding the cost of steel reinforcement.

1

-

-

... More
a) R.C.C. M-25 in Beams and Columns:- Terrace

10.5

343441

32708.7

... More
b) R.C.C.M-25 in Floor and Roof slab, landing, balconies, projecting, sun shades and chajjas.:-Terrace

15.67

420878

26858.9

... More
c) R.C.C. Wall:-Terrace

14.5

237965

16411.4

... More
Providing & fixing TOR Fe-500 reinforcement bars (make of Sail, Tata) for RCC work of required diameter & of approved quality including straightening, cutting, bending, binding welding , joining (if necessary),tying the grills, hoisting, lowering and and placing in position as per the approved design & drawings with provision of fan hooks including cost, conveyance and taxes of reinforcement bars or tor steel and binding wires of 18 to 20 gauge and labour required for the work in all heights as per the specification & direction of E-I-C. (Linear measurements will be taken & quantity will be calculated on standard weight. Lap length of bars & Weight of binding wire will not be considered for measurement.)

1

-

-

... More
Terrace

66.26

424594

6408

... More
Providing 6mm thick cement plaster in cement mortar of (1:4) to RCC surfaces such as ceilings of roof slabs, stairs, landings, chajja, shelves, columns, beams and lofts etc. including roughening/chipping, scraping and cleaning and finishing the plastered surface smooth using wooden floats, bars, etc. only to proper plumbs and level, making grooves, beads and drip coarse to give required ornamental finish as per drawing including cost of all materials, conveyance, loading and unloading, taxes, royalties, cost of all labour, scaffolding, staging, watering before plastering and curing, sundries and T&P, etc. complete as per direction of the Engineer-in-charge.

1

-

-

... More
Terrace

322.74

34404

106.6

... More
Providing and fixing in position of size 600mm x600 mm (Medium Duty i.e. the weight of duty not less then 60 Kg)Square C.I.manhole cover and frame of required shape and approved quality as per direction of E.I.C.

1

-

-

... More
Terrace

6

39744

6624

... More
Providing and fixing in position Polyproplene Footsteps of required shape and approved quality as per the direction of E.I.C.

1

-

-

... More
Terrace

30

6960

232

... More
Providing & applying water proofing treatment (Two Component glass fibre reinforced specially formulated acrylic modified, cementitious elastic coating system) using Sika Top Seal 109 hi & Sika Fab-1 or equivalent (glass fibre cloth) @ 3Kg/Sq.mtr before one coat of Sika Top Seal 109 hi or equivalent Primer @ 200 gm/Sq.mtr over the cleaned RCC Horizontal Surface & Outer retaining wall etc including the cost of all materials, cost of labour, conveyance, taxes, T&P, etc. all complete as per the direction of Engineer-in-Charge.

182.15

85577

469.82

... More
Fire-Fighting & Raw Water UGR with Pump-House.:-Earth work in excavation of foundation trenches in following kinds of soil including moorum stony earth and earth mixed with boulders except sheet rock and boulders requiring blasting including dressing of sides and levelling the bed up to the required depth and depositing the excavated materials away from the work site with all leads and lifts, including shoring, shuttering & dewatering (if required) with cost of labour, labour cess, hire & running charges of all machineries, sundries & T&P required for the work complete

1

-

-

... More
a) Up to 1.50 m depth(Hard soil)

308

41395

134.4

... More
a) Up to 1.50 m depth(Laterite rock)

0.45

526

1169.2

... More
b) From 1.50 m to 3.0m depth(Lateriterock)

308

363403

1179.88

... More
c) Up to 4.5 m depth(Laterite rock)

263

313117

1190.56

... More
d) From 4.5m to 6.0m depth(Lateriterock)

37

44446

1201.25

... More
Filling in foundation and plinth with excavated materials including watering and ramming as directed by the Engineer-in-charge .

305.48

30151

98.7

... More
Disposal of surplus earth/debris staked at work site by mechanical means including loading and unloading and disposing the same within a lead of 5 km with hire running charges of all machineries, cost of all labour, labour cess, T&P required for the work etc. complete as directed by Engineer-In-Charge.

610.97

92359

151.17

... More
Supplying, filling in foundation and plinth with sand including watering and ramming, poking & compacting including cost, conveyance, royalties, taxes of the materials and cost of all labour, labour cess, T&P etc. required for the work complete as directed by the Engineer-in-Charge.

30

9621

320.7

... More
Providing and laying plain cement concrete of proportion (1:3:6) in foundation and floors using 2.5cm to 4 cm. size black hard crusher broken granite stone metal and screened and washed sharp sand for mortar of approved quality and from approved quarry including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm. thick in each layer including cost, conveyance, royalties, taxes of all materials and cost of all labour, labour cess, T&P, etc. required for the work including shoring, shuttering and dewatering if required including hire & running charges of all machineries required for the work etc complete as per the direction of the Engineer-in-charge.

30

119412

3980.4

... More
Providing, lifting, hoisting and laying in position machine batched , machine mixed and machine vibrated design mix cement concrete of M-30 including the cost of Centering and Shuttering (minimum cement content not less than 300 Kg/Cum) grade in reinforced cement concrete structural elements using black hard crusher broken granite chips of approved quality from approved quarry including mixing and compacting to proper shape and size, level and plumbs and finishing the exposed surfaces smooth including the cost of all materials, cost of labour, conveyance, taxes, loading, unloading, royalties, watering and curing for the required period, T&P , hire & running charges of concrete mixer and vibrator, cost of Admixtures in recommended proportions ( as per IS 9103 ) to accelerate, retard setting of concrete, improve workability without impairing strength and durability etc. complete as per the direction of the Engineer-in-charge but excluding the cost of steel reinforcement.

1

-

-

... More
a) R.C.C. M-30 in foundation and footing bases raft

62

304581

4912.6

... More
b) RCC M-30 for wall

89

437221

4912.6

... More
c) RCC M-30 RCC STAIRCASE

1.31

6435

4912.6

... More
d) RCC M-30 RCC ROOFBEAM

9.66

47455

4912.6

... More
e) RCC M-30 RCC ROOFSLAB

23.12

109748

4746.9

... More
Providing & fixing TOR Fe-500 reinforcement bars (make of Sail, Tata) for RCC work of required diameter & of approved quality including straightening, cutting, bending, binding welding , joining (if necessary),tying the grills, hoisting, lowering and and placing in position as per the approved design & drawings with provision of fan hooks including cost, conveyance and taxes of reinforcement bars or tor steel and binding wires of 18 to 20 gauge and labour required for the work in all heights as per the specification & direction of E-I-C. (Linear measurements will be taken & quantity will be calculated on standard weight. Lap length of bars & Weight of binding wire will not be considered for measurement.)

263

1685304

6408

... More
Providing 6mm thick cement plaster in cement mortar of (1:4) to RCC surfaces such as ceilings of roof slabs, stairs, landings, chajja, shelves, columns, beams and lofts etc. including roughening/chipping, scraping and cleaning and finishing the plastered surface smooth using wooden floats, bars, etc. only to proper plumbs and level, making grooves, beads and drip coarse to give required ornamental finish as per drawing including cost of all materials, conveyance, loading and unloading, taxes, royalties, cost of all labour, scaffolding, staging, watering before plastering and curing, sundries and T&P, etc. complete as per direction of the Engineer-in-charge.

1009.98

107664

106.6

... More
Providing and applying 2 coats plastic emulsion paint of approved quality and shade over a coat of wall primer of approved quality to surfaces (interior) including throughly brushing the surface free from foreign materials, sand papering smooth the intermediate coats, providing necessary putty & primer including of all materials, labour, conveyance, taxes, royalties, scaffolding, watering, curing, sundries, tools and plants etc as per the direction of Engineer-in-charge. (colour & shade to be approved before procurment & use)

544.52

33596

61.7

... More
Providing & Painting two or more coats with Premium Acrylic Smooth Exterior Paint with Silicon Additives of required shade after preparation of surfaces including brushing the suface to make free from foreign materials, sand papering, Priming, etc. including the cost, conveyance, taxes of all materials, cost of all materials, T&P, etc, all complete as per the direction of Engineer-in-Charge.

465.46

26158

56.2

... More
Providing 40 mm thick A.S. flooring with base C.C. (1:2:4) using 20 mm size hard granite crusher broken chips after roughening, scraping, cleaning the base, watering well and laying flooring to required level in panels 2m x 2m (Max.) by using dividing glass strips of 40 x 4 mm size, well compacted and top finishing smooth by trowel with a thick coat of neat cement punning, polished well including cost of all materials, labour, conveyance, taxes, sundries, T&P, curing etc. complete as per direction of Engineer-in-Charge.

169

39596

234.3

... More
Providing and fixing in position Polyproplene Footsteps of required shape and approved quality as per the direction of E.I.C.

48

11136

232

... More
Providing and fixing in Puddle Collar for 200mm dia approved quality as per the direction of E.I.C.

4

2400

600

... More
Providing and fixing in Puddle Collar for 50 mm dia and approved quality as per the direction of E.I.C.

4

2400

600

... More
Providing and laying water proofs with polymeric bituminous membrane (Plastic felt) of 2.25Kg/Sqm and 1.5mm thickness consisting of layers having center core of 20 microns thermoplastic high molecular high density polyethylene H.M.H.D.P.E. film of grade 2504 including priming the surface with bituminous primer @ 0.3 Kg/Sqm providing a coat of hot blown bitumen of 1.32 kg / Sqm, applying and laying plastic felt membrane with 10 c.m overlap adhered to blown bitumen of 85/25 or 90/15 grade and covered with a layer of hot blown bitumen @ 1.2Kg/Sqm etc complete as per direction of E.I.C.

544.52

108196

198.7

... More
Supplying, fitting & fixing of M.S Rolling shutter confirming to BIS specification as per approved design and drawing including cutting holes in brick/RCC surface and grouting the hold fasts/clamps properly in line and plumb with CC(1:2:4) using 12mm size black hard granite chips and making good to the damages including cost of all materials with taxes, transportation, all labour, sundries, T&P and priming one coat with approved quality metal primer etc. complete as per direction of Engineer in charge. 80 x 1.25mm MS lath with 1.25mm thick top cover

1

-

-

... More
Rolling Shutter 1.5x3.0 Mtr=4.5 Sqm

4.5

9810

2180.01

... More
Providing and fixing ball bearing for rolling shutters.

3

1137

379.29

... More
Extra for providing mechanical device chain and crank operation for operating rolling shutters. Exceeding 16.80sqm in area.

4.5

3258

724.07

... More
Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32 mm x 32 mm x 2 mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, taxes of all materials, labour, T&P etc. required for the complete in all respect.

314.34

97759

311

... More
Providing & fixing of Fixed ventilators of approved make to be fabricated from roll formed sections made of pre-painted steel (base steel as per IS-513 of 0.6mm. Thick D quilty, galvanized as per IS-277 with Zinc of 120Gm/Sqm) with paint specification being with primer of 5-7 microns and finished paint with plyster paint (black /pearl white/Choclate Brown ) of 12-16 microns along with alkyd backer at the back of 5-7 micron and the size of outer frame being of 46x52mm and with all vetrical & horizontal mullions ar of 46x70mm & fixed beading are of 18x25mm.Accessories /gasket are to be placed.

10.4

50657

4870.91

... More
Design, supplying , fitting ,fixing,erection,installation ,Testing and comissioning and obtaining statutory approval of 3 Ton capacity Hoisting Arrangement with supplying of all materials,labour ,T$P fabrication of chain pulley travelling arrangement with fixing of ISW Beam size-550x250x17.6x10.5 mm alongwith fabrication of end plate support 12mm plate size-250x250mm 6 nos. electric arc welding at site in pumphouse both the side of ISW Beam and Centre of the beam for firmly support of ISW Beam on the wall over the roof slab and 3 ton capacity of chain pulley with travelling arrangement of chain pulley etc all complete as per direction of Engineer in charge

1

71003

71003

... More
Laying of Gravity Sewerage System:-Earth work :

1

-

-

... More
Earth work in all kinds of soil within 50m initial lead & 1.5m initial lift including dressing, levelling & breaking clods to maximum 5cm to 7cm & laying in layers not exceeding 0.3m in depth & as per specification & direction of Department.

152

22496

148

... More
Filling foundation trenches and Plinth with excavated & selected earth, laying in layers not exceeding 23cm thick well watered & rammed etc. complete including labour , T&P, lead & lift cost & conveyance, loading, unloading etc. complete as per specification & direction of EIC.

142

14015

98.7

... More
Providing all materials,labour,T&P for construction of Cement Concrete (1:2:4) Pedestal with 12mm size h.g.c.b. chips as per approved design & drawing for RCC pipe. The cost inclusive of all taxes, royality, hire & running charges of all machineries, Transportation charges with all consumables etc. all complete as per specification & direction of EIC.

1

-

-

... More
For 250mm dia pipe

33

22869

693

... More
For 200mm dia pipe

165

114345

693

... More
For 150mm dia pipe

39

18876

484

... More
Providing all materials, labour, T&P and laying of Centrifugally cast (spun) RCC non pressure pipes of class NP2 with socket & spigot ends confirming to IS-458 with ISI mark in standard lengths suitable for push on joints including lowering the pipes in to trenches to required depth below G.L, with proper allignment & gradient, testing, commissioning, de-watering (if required) including rubber gasket as per IS-5382/1985 with ISI mark with all taxes & duties etc. all complete as per specification & direction of EIC. (Excluding cost for earth wok, back filling which will be paid separately).

1

-

-

... More
250mm (NB) dia NP2 RCC S/S pipe

33

27489

833

... More
200mm (NB) dia NP2 RCC S/S pipe

165

105600

640

... More
150mm (NB) dia NP2 RCC S/S pipe

39

20787

533

... More
Providing all materials, labour, T&P required for construction of RCC M-25 man hole chamber of following sizes having cube strength 250 Kg/cm2 at 28 days confirming to IS-456/2000 & IS-3370 at all locations & height using h.g. stone aggregate (Crusher broken) of 20mm & down size including machine mixing, lifting, hoisting, conveying, placing in position, mechanical consolidation, curing, de-watering (if required). The minimum thickness of RCC base slab, all side walls & roof slab shall be not less than 150mm, 150mm & 125mm (avg.) respectively. The cost shall be inclusive of rigid, levelled & plumbed centering & shuttering to required slope, allignment & size for all kinds of RCC work with steel/ ply centering materials with all bracing, ties, anchorage & supports and removing the same after required paid & placing M.S.Reinforcement HYSD bar of required dia including cutting, bending, straightening of approved quality as per approved design & drawing & tying the grills for RCC works & placing in position using binding wires (18 to 20 gauge soft drawn & cold annealed).

1

-

-

... More
PCC 1:3:6 with 40mm size h.g.c.b. metal of 100mm thick, moulding & shaping the channel & benching with C.C. 1:2:4 with 12mm size h.g.c.b. chips, 12mm thick cement plaster 1:3 with cement punning on inner wall surface, earth work excavation in all types of soil/rock including cement concrete cutting as per site condition, filling the foundation base with sand duly watered & rammed, providing, fitting & fixing of pre-cast factory made man hole cover with frame ( heavy duty) for clear opening 560mm dia, providing, fitting & fixing of poly propylene steel reinforced man hole steps of approved quality & size in two parallel line of 300mm spacing in vertical wall with centre to centre 375mm (staggered) etc.all complete as per specification & direction of EIC.

1

-

-

... More
Manhole chamber of Inner size 1200mmx900mmx 900mm depth.

14

530306

37879

... More
Manhole chamber of Inner size 800mmx900mmx 900mm depth.

5

171645

34329

... More
Extra for every additional depth of 0.10mtr. or part there of manhole size 1200mmx900mm from 900mm depth upto 1500mm depth.

1.6

16176

10110

... More
Extra for every additional depth of 0.10mtr. or part there of manhole size 800mmx900mm from 900mm depth upto 1500mm depth.

1

8416

8416

... More
50 KLD Sewage Treatment Plant:- MECHANICAL ITEMS

1

-

-

... More
Design,Construction,testing & commissioning and obtaining statutory approval of Sewage Treatment Plant(STP) of capacity 50 KLD with conveyance filter press of MBBR/FMR Technology with feed pump,Bar Screen,Aeration Tank,Diffuser(Tube Type),Blower,Filter Press,Secondary Clarifier,MGF,MGF Feed Pump,ACF,Butterfly Valve,UV System,Pressure Gauge,Pipe including erection and commissioning etc. all complete as per PH specification & direction of EIC.

1

1640000

1640000

... More
CIVIL ITEMS:- Supply of all material,labour & T&P Civil Works for Construction of RCC M30 with Excavation of Earth work for Raft,Equalisatin Tank,Sludge Holding Tank,Treated Water Tank ,Clarified Tank & Drain Pit etc all complete as per direction of EIC for 50 KLD STP

1

1068132

1068132

... More
Rain water harvesting Structure with Inlet Chamber,Filtration tank & Collection Pit.

1

-

-

... More
Earth work in excavation of foundation trenches in all kinds of soil including moorum stony earth and earth mixed with boulders except sheet rock and boulders requiring blasting including dressing of sides and levelling the bed up to the required depth and depositing the excavated materials away from the work site with all leads and lifts, including shoring, shuttering & dewatering (if required) with cost of labour, labour cess, hire & running charges of all machineries, sundries & T&P required for the work complete

1

-

-

... More
Upto 1.5 Mtr Depth

188.15

27846

148

... More
From 1.5 Mtr to 3.0 Mtr Depth

167.87

26637

158.68

... More
From 3 Mtr to 4.5 Mtr Depth

161.82

27405

169.36

... More
From 4.5 Mtr to 6.0 Mtr Depth

91.69

16508

180.05

... More
Filling in foundation and plinth with excavated materials in trenches for laying pipes including watering and ramming as directed by the Engineer-in-charge .

203.18

20053

98.7

... More
Supplying, filling in foundation and plinth with sand including watering and ramming, poking & compacting including cost, conveyance, royalties, taxes of the materials and cost of all labour, labour cess, T&P etc. required for the work complete as directed by the Engineer-in-Charge.

12.73

4082

320.7

... More
Providing and laying plain cement concrete of proportion (1:3:6) in foundation and floors using 2.5cm to 4 cm. size black hard crusher broken granite stone metal and screened and washed sharp sand for mortar of approved quality and from approved quarry including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm. thick in each layer including cost, conveyance, royalties, taxes of all materials and cost of all labour, labour cess, T&P, etc. required for the work including shoring, shuttering and dewatering if required including hire & running charges of all machineries required for the work etc complete as per the direction of the Engineer-in-charge.

32.62

129840

3980.4

... More
Providing, lifting, hoisting and laying design mix cement concrete of M-25 (minimum cement content not less than 403 Kg./cm) grade as reinforced cement concrete using black hard crusher broken granite chips of approved quality from approved quarry including mixing and compacting to proper shape and size, level and plumbs and finishing the exposed surfaces smooth including cost of scaffolding, watering and curing for the required period, cost of all materials with taxes, royalties transportation, loading and unloading, all labour, sundries, T&P , hire & running charges of concrete mixer and vibrator, including cost of Admixtures in recommended proportions ( as per IS 9103 ) to accelerate, retard setting of concrete, improve workability without impairing strength and durability etc. complete as per the direction of the Engineer-in-charge but excluding the cost of r reinforcement, centering and shuttering for the work.

109.93

523596

4763

... More
Providing & fixing TOR Fe-500 reinforcement bars (make of Sail, Tata) for RCC work of required diameter & of approved quality including straightening, cutting, bending, binding welding , joining (if necessary),tying the grills, hoisting, lowering and and placing in position as per the approved design & drawings with provision of fan hooks including cost, conveyance and taxes of reinforcement bars or tor steel and binding wires of 18 to 20 gauge and labour required for the work in all heights as per the specification & direction of E-I-C. (Linear measurements will be taken & quantity will be calculated on standard weight. Lap length of bars & Weight of binding wire will not be considered for measurement.)

115.34

739098

6408

... More
Providing strong, rigid, leveled and plumbed centering and shuttering to required shape and size for all kinds of R.C.C. works in the items mentioned below with wooden or steel centering materials with all necessary bracing, ties and supports for level centering covered with bituminous paper including provision of necessary holes and pockets, electrical conduit pipe, P.H. pipes, fan hooks or boxes, switch board insert plates, clamps and extension bars etc., dismantling and removing the shuttering after the required interval from the date of casting as per the direction of the Engineer-in-charge., including cost of all materials with transportation, taxes, loading and unloading ,all labour for the work, sundries, T&P scaffolding etc. complete

1

-

-

... More
In foundation

23.57

2036

86.4

... More
RCC Walls

424.03

195290

460.56

... More
RCC Slab

80.35

27117

337.5

... More
RCC Beams

21.08

11381

539.9

... More
Providing 1st class Fly Ash brick masonry work in F & P using (250mmx120mmx80mm ) size having crushing strength not less than 75Kg/Sqcm in cement mortar (1:4) for brick masonry walls after immersing the bricks for minimum 6 hours in water before use with all necessary projections, splays cutting, circular moulding, corbelling etc as per drawings including cost, conveyance, all taxes, royalties, loading and unloading of all materials and all labour for work including scaffolding, watering and curing, sundries, T&P etc. complete as per the direction of the Engineer-in-charge.

5.89

20571

3492.6

... More
Providing 12mm thick cement plaster to the inside surface of brick masonry wall in cement mortar (1:4) with neat cement punning including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth using wooden floats only to proper plumbs and level and making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading, all taxes and royalties, all labour, scaffolding, watering and curing, sundries and T&P etc. complete as per direction of the Engineer-in-charge.

23.53

2357

100.2

... More
Providing and laying Stainless steel wire guage (Grade-304) aperture 1.4 mm and 0.50 mm dia wire over filter material laid inside the filtration tank to retain foreign particles coming with the sterm water as per specifications and drwaing including the cost, conveyance, taxes of materials, cost of all labour, labour cess, T&P, etc. as per the direction of Engineer-in-charge.

60

58464

974.4

... More
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.

30

19350

645

... More
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-incharge.

18

25036

1390.9

... More
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.

9

3816

424

... More
providing and fixing MS RUNG IN Recharge pits h including the cost, conveyance, roylties, taxes, loading & unloading of all materials, cost of all labour, labou cess, T&P, etc. complete as per the direction of Engineer-in-Charge.

129.6

18144

140

... More
Providing 40 mm thick A.S. flooring with base C.C. (1:2:4) using 12 mm to 20 mm size hard granite crusher broken chips after roughening, scraping, cleaning the base, watering well and laying flooring to required level in panels 2m x 2m (Max.) by using dividing glass strips of 40 x 4 mm size, well compacted and top finishing smooth by trowel with a thick coat of neat cement punning, polished well as per direction of Engineer-in-Charge including the cost , conveyance, taxes of all materials, labour, sundries, T&P, curing etc. complete.

20.44

4789

234.3

... More
Providing and fixing 600mm dia C.I. Manhole cover over Filteration tank and Pumping Pit including cost, conveyance, taxes of all materials, cost of all labour, labour cess, T&P, etc. complete as per the direction of Engineer-in-Charge.(Make NECO ISI Marked Round Manhole cover with Circular Frame(180 kg))

8

158760

19845

... More
Supplying & laying in trenches 110 mm dia Unplasticized UPVC Pipes including joiting with supplied solvent cement by non-heat application method including testing as per standard specification including earth work excavation of 300mm deep trenches in all kinds of soil in proper slope with type-C standard bedding CC 1:4:8 the required depth & refilling of pipe line trenches after laying and testing of pipe line etc all complete as per the direction of the Engineer-in-charge(As per Cat no. M09110309 of Astral)

15

4290

286

... More
Recharge Bore Well:- Labour for drilling a perfectly vertical bore hole of specified dia (200mm x 150mm) for a specified depth of 15mtrs below the ground level through consolidated and unconsolidated rock with down the hole hammer drilling rigs or combination drilling rigs including use of own rigs with its accessories, T&P and consumables etc for lowering of 200mm dia PVC pipes for housing as per the direction of Engineer-in-Charge

30

18870

629

... More
Lowering of 200mm dia PVC casing with or without slotted pipes as per the necessity from ground level and fitted and fixed up in perfectly vertical position, including cutting and thresding pipe and slotted pipe and supplying and fixing all jointing materials, T&P, etc. complete and keeping the top of the casing pipe threaded to receive crown to prvent the entry of foreign meterials from above as per the direction of Engineer-in-charge.

32

47136

1473

... More
Cleaning and developing the bore well using compressor contineously worked till clear and adequate discharge is obtained from the bore well including supply and use of all necessary equipment and cost of all labours as per the direction of Engineer-in-Charge.

2

9168

4584

... More
External Water Supply (Tapping Point From Government PH Water Supply Line to Raw Water UGR ):- Supplying all material ,Labour T&P for tapping connection from municipal PH pipeline to 296.6 cum RCC UGR along with Riser Pipe and fittings i.e NR Valve,Sluice Valve,Kinetic Air Valve,Electromagnetic Flow Meter for flow recording with flow meter chamber,Provision for lock and key arrangement,Valve Chamber and MS Flange Fittings.Painting two coats of approved Brand anticorrosive paint over a coat of primer etc all complete as per direction of Engineer-in-charge of Proposed SLDC Office Complex at Mancheswar Bhubaneswar.

1

200000

200000

... More
INTERNAL ELECTRICAL:

1

-

-

... More
Modular Wiring Items: Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor with earth wire single core cable in surface / recessed medium class PVC conduit, with modular switch, socket, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. CATAGORY AS FOLLOWS

1

-

-

... More
Single light/fan/ex.f point controlled by one 6A switch or first light/fan/exf/cb point or group control.modular GROUP-A

198

117216

592

... More
Single light/fan/ex.f point controlled by one 6A switch or first light/fan/exf/cb point or group control.modular GROUP-B

288

186624

648

... More
Single light/fan/ex.f/call bell point controlled by one 6A switch or first light/fan/exf/cb point or group control.modular GROUP-C

622

471476

758

... More
Total room controller with 16A CARD LOCK system with all accessories control entire light/fan/ex. Fan/call bell point.

10

2670

267

... More
subsequent point of group control

188

95692

509

... More
6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type) & other required accessories of ISI marked as approved.Make-Havells Crabtree/Roma/legrand,

278

47816

172

... More
6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type) cover,modular board & other required accessories of ISI marked as approved.Make-Havells Crabtree/Roma/legrand

288

102816

357

... More
2x6A Plug on the separate board For Power supply point or TV point & other use for Data center/SLDC area with complete fitting by 02 nos of 5A switch & socket(modular type) cover,modular board & other required accessories of ISI marked as approved.Make-Havells Crabtree/Roma/legrand,

39

27027

693

... More
3x6A Plug on the separate board For computer point & other use,modular type with box & cover. Make-Havells Crabtree/Roma/legrand,

98

117992

1204

... More
Supplying and fixing 15/16A modular socket with 15/16A Switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Make-Havells Crabtree/Roma/legrand,

76

41724

549

... More
Supplying and fixing 2 nos 15/16A modular socket with 15/16A Switch & 1 no 6A modular switch with socket with box & modular plate & switch box including connections but excluding modular plate etc. as required. Make-Havells Crabtree/Roma/legrand,

298

323926

1087

... More
Wiring for circuit/submain wiring with the following mentioned size PVC insulated, copper conductor, single core cable (Finolex/ Polycab/L&T) or any other equivallent reputed make ISI marked as approved, in surface/ recessed PVC conduit medium (AKG or any other equivallent reputed make ISI marked as approved) as required.

1

-

-

... More
2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor.(LDB to LSB/LIGHT CKT) in existing conduit

855

36765

43

... More
2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor.(BDB to LSB/LIGHT CKT/5A PLUG/INVERTER POINT TO EACH QTR)

4233

474096

112

... More
4 nos single core 2.5 sq. mm copper wire for phase and neutral and 02 nos of single core 1.5 sq. mm copper wire for earth continuty conductor.(LDB to LSB/5A SOCKET)

4521

795696

176

... More
2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor.(PDB to PSB/ GAYSER POINT/AC POINT/ROOM LIGHT CONTROL TO CORRIDOOR CARD POINT/DG PANEL ACCL TO EACH QTR ESSENTIAL LOAD)

2250

290250

129

... More
4 nos single core 4 sq. mm copper wire for phase and neutral and 02 nos of single core 2.5 sq. mm copper wire for earth continuty conductor.(PDB to PSB/GAYSER. POINT/AC POINT/DG PANEL ACCL TO EACH QTR ESSENTIAL LOAD)

1685

355535

211

... More
2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 4 sq. mm copper wire for earth continuty conductor.(LFDB TO LBDB)

355

56800

160

... More
4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductor.(LFDB TO LBDB/power unit/point)

397

101632

256

... More
4 nos single core 10 sq. mm copper wire for phase and neutral and 02 nos of single core 6 sq. mm copper wire for earth continuty conductor.(LFDB TO FLOOR PANEL TO TPN BDB)

988

377416

382

... More
4 nos single core 16 sq. mm copper wire for phase and neutral and 02 nos of single core 10 sq. mm copper wire for earth continuty conductor.(FLOOR PANEL TO TPN BDB)

999

588411

589

... More
2 nos single core 16 sq. mm copper wire for phase and neutral and 01 nos of single core 10 sq. mm copper wire for earth continuity conductor.(FLOOR PANEL TO BDB )

398

129748

326

... More
2 nos single core 10 sq. mm copper wire for phase and neutral and 01 nos of single core 6 sq. mm copper wire for earth continuity conductor.(FLOOR PANEL TO BDB )

333

73260

220

... More
Supplying and fixing 5/6A modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required. of Anchor/ wipro/legrand /Havells make.

68

6324

93

... More
Supplying and fixing 3 pin 5/6A modular socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. of Anchor/ wipro/legrand/Havells make.

68

6732

99

... More
Supplying and fixing 15/16A modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required. ofAnchor/ wipro/legrand/Havells make. make.

121

16577

137

... More
Supplying and fixing 15/16A modular socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. ofAnchor/ wipro / legrand/Havells make. make.

121

22143

183

... More
Supplying and fixing 20 amps, 240 volts, SPN, industrial type socket outlet, with 2 pole and earth metal enclosed plug top along with 32 amps. C-series, SP MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet, and complete with connections, testing and commissioning etc. as required. Legrand/Hager/Siemens make

48

25920

540

... More
Supplying and fixing 32 amps, 415 volts, TPN, industrial type socket outlet, with 4 pole and earth metal enclosed plug top along with 32 amps. C-series, TP MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet, and complete with connections, testing and commissioning etc. as required. Legrand/Hager/Siemens make

7

30016

4288

... More
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. MAKE-Legrand/L&T/Siemens

1

-

-

... More
4 moudle(125mmx75mm)

188

44180

235

... More
1 moudle(75mmx75mm)

188

35344

188

... More
12 moudle(200mmx150mm)

255

114750

450

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.MAKE KINJAL/ AKG

1

-

-

988

79040

80

988

82004

83

... More
Supply and fixing modular type indicator on the existing switch box/cover of Anchor make.

218

20274

93

... More
Supplying and installation of AC starter Modular type,L&T make or any other equivalent reputed make as approved coil voltage-415 Volt A.C. & O/L range of 9-14A range on mod Box of suitable size including moudlar cover.

33

19833

601

... More
Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing switch box/cover of Anchor make.

41

9471

231

... More
Light fitting Fixture & Fan

1

-

-

... More
Supplying, installation, of exhaust fan of heavy duty 300 mm sweep with louvers (Havells make or any other equivalent reputed make star rated as approved) of exhaust fan in the existing wall, including fixing & conntection.

33

77484

2348

... More
Supplying, installation, of exhaust fan of heavy duty 225 mm sweep with louvers (Havells make or any other equivalent reputed make star rated as approved) of exhaust fan in the existing wall, including fixing & conntection.

41

89503

2183

... More
Supplying, installation, testing and commssioning of 1400 mm sweep white/milky colour ceiling fan of Havells velocity/ CROMPTRON JURA Make or any other equivalent reputed make star rated as approved including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required.(With fan Regulator)

188

461540

2455

... More
Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour ceiling fan of Havells velocity/CROMPTRON JURA Make or any other equivalent reputed make star rated as approved including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required.(With fan Regulator)

136

280840

2065

... More
Supplying and fixing of FTL fitting with glass cover, in existing false ceiling/Surface wire guard etc. of HAVELLS,MODEL: PLUTO NEO 2X2 PLR42WLED840S make /PHILIPS MAKE make or any other reputed make of approved quality including supply and fixing of led lamp with connection etc. as required.

131

538148

4108

... More
Supplying and fixing of Surface type LED fitting with glass cover, wire guard etc. of 21W of HAVELLS ENDURANEOSURFACEDLS21WLED857S/PHILIPS MAKE /PHILIPS/WIPRO or any other reputed make of approved quality including supply and fixing of LED with connection etc. as required.

152

293360

1930

... More
Supplying & installation, testing and commissioning of prewired, LED TUBE fittings with one No 1x20w watt,6K LED tube,of HAVELLS MODEL: LUMILINE 20W LED 865/PHILIPS MAKE OR any other equivallent reputed make ISI marked as approved) with all accessories and tubes etc. directly on ceiling/wall on two wooden round block, including connections with 1.5 sq mm PVC insulated, copper conductor, single core cable etc.as required.

298

175820

590

... More
Supplying & installation, testing and commissioning of prewired, LED TUBE fittings with one No 2x20w watt,6K LED tube,ofHAVELLS MODEL: MAGNUM GRAND 40W LED 857/PHILIPS MAKE OR any other equivallent reputed make ISI marked as approved) with all accessories and tubes etc. directly on ceiling/wall on two wooden round block, including connections with 1.5 sq mm PVC insulated, copper conductor, single core cable etc.as required.

98

363188

3706

... More
Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)

655

28165

43

... More
Supplying and fixing of Concealed type LED fitting with glass cover, wire guard etc. of 18W HAVELLS MODEL: ENDURANEODLR18WLED830S RECESS/PHILIPS MAKE or any other reputed make of approved quality including supply and fixing of LED with connection etc. as required.

302

445148

1474

... More
Supplying and fixing of GATE LIGHT LED fitting with glass cover, wire guard etc. Of 25W HAVELLS MODEL: RUBY (CLEAR) 25W LED 757 POST TOP, IP65 /PHILIPS MAKE or any other reputed make of approved quality including supply and fixing of LED with connection etc. as required.

8

55328

6916

... More
Supplying and fixing of BUILDING FOCUS LIGHT LED fitting with glass cover, wire guard etc. of 70W HAVELLS MODEL: JETA PRO PLUS SFL 120W LED 757LTG LED FLOOD LIGHT /PHILIPS MAKE or any other reputed make of approved quality including supply and fixing of LED with connection etc. as required.

4

61596

15399

... More
Supplying and fixing of BUILDING FOCUS ARCHITECTURAL LIGHT LED fitting with OUTDOOR CANOPY mounted on outside wall of 15W HAVELLS MAKE: (1500-3000K) /PHILIPS MAKE or any other reputed make of approved quality including supply and fixing of LED with connection etc. as required.

20

71700

3585

... More
Supplying and fixing of EVENT AREA TRAK LIGHT LED fitting with glass cover, wire guard mounted in wall. of 20W HAVELLS MODEL: CYLINDRO 15W LED WITH 1 MTR 3 PHASE TRACK /PHILIPS MAKE or any other reputed make of approved quality including supply and fixing of LED with connection etc. as required.

15

85755

5717

... More
Supplying and fixing of STRIP LIGHT (Flexi type) LED fitting with driver for variable colour display, wire guard mounted in false ceiling etc. of HAVELLS MODEL: LED FLEXISTRIP 5M TRIP 2029WLED8305 (5 MTRS) (24W SMD)/PHILIPS MAKE with driver or any other reputed make of approved quality including supply and fixing of LED with connection etc. as required.

50

84050

1681

... More
Supplying and fixing of HIGH BAY down LIGHT LED fitting with glass cover, wire guard etc. of 50W HAVELLS MODEL: ENDURA HIGHBRITE PLUS 50W LED HIGHBAY /PHILIPS MAKE or any other reputed make of approved quality including supply and fixing of LED with connection etc. as required.

10

81170

8117

... More
TELEPHONE & LAN WIRING

1

-

-

... More
Supplying and drawing CAT6 LAN WIRE protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required

4521

230571

51

... More
Supply & drawing of the 4 pair,0.5 sqmm telephone cables in existing surface/ recessed conduit etc. as required.

1899

58869

31

... More
Supplying and telephone socket socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required

88

9328

106

... More
Supply, Delivery, Installation & Testing of Information Outlet with SMB I/O boards containing a clip-in-type modular Data socket with top fixed on metallic concealed box including connections and making good the damages caused complete as per direction of Engr.-in-charge.

288

44928

156

... More
Supplying & Commissioning of Telephone Hand Set.

88

39424

448

... More
Supplying & installation of 100 pair KRONE make moudles with locking & key arrangements fabricated with MS sheet & powder coated to be fixed on concealed manner incl. good the damages.

8

13512

1689

... More
260 Lines EPABX expandable upto 256 Lines

121

211750

1750

... More
4 Core cabling PVC pipe in concealed manner

2955

162525

55

... More
FCBC 25A 48 Volts

8

256000

32000

... More
Constant Voltage Transformer

8

76000

9500

... More
Batteries 12V 60 Ah

16

80000

5000

... More
Lightening Protectors

8

8000

1000

8

156000

19500

... More
LAN: Supplying and Commissioning of 6U Rack with all accessories.

55

412500

7500

... More
Supplying & Commissioning of Managed Cat 6 24 Port Switch.

120

576000

4800

... More
Supplying & Commissioning Cat 6 24 Port Patch Panel.

120

318000

2650

... More
Supplying and fixing:

1

-

-

... More
Patch Chord CAT 6 One meter long.

500

75000

150

... More
Patch Chord CAT 6 Two meter long.

500

75000

150

... More
BDBS, DB, AC DB, FLOOR PANELS, MCBS: Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts, on surface/recess, complete with terminal blocks, duly prewired with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Legrand/L&T/Siemens make, or any other equivallent A catagories reputed make ISI marked as approved

1

-

-

... More
4way, Double Door TPN DB(FOR LIGHT,POWER,UPS AC INDOOR,3-PH)

20

41520

2076

... More
12 way SPN DB (Double door)(ALL LIGHT WITH CORRIDOOR/COMMON AREA,EM LIGHT,UPS LOAD, EM LOAD LIGHT LOAD )

30

54510

1817

... More
4 way MCB Enclosure DB (GLAZED door)(only each EM. CONNECTION DATA CENTER/AC ODU as outdoor type))

41

32595

795

... More
8 way TPN DB (Double door)UPS/LIGHT/RAW POWER

20

52100

2605

... More
Supplying and fixing 20 amps rating, 240 volts, C series, Double poles MCB of Legrand/L&T/Siemens make or any other equivallent A catagories reputed make ISI marked as approved in the existing MCB DB complete with connections.

25

7875

315

... More
Supplying and fixing 20 amp rating, 415volts, C series, FOUR poles MCB of Legrand/L&T/Siemens make or any other equivallent A catagories reputed make ISI marked as approved in the existing MCB DB complete with connections.

18

15390

855

... More
Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series, single poles MCB of Legrand/L&T/Siemens make or any other equivallent A catagories reputed make ISI marked as approved in the existing MCB DB complete with connections.

2500

290000

116

... More
Supplying and fixing 40 Amps rating, TPN, 415 volts, RCCB,300mA Legrand/L&T/Siemens make or any other reputad equevallent A catagories make ISI marked as approved in the existing MCB DB complete with connections, testing and commissioning etc. as required.

58

125686

2167

... More
Supplying and fixing 25Amps DP 240 volts, RCCB,300mA Legrand/L&T/Siemens make or any other reputad equevallent A catagories make ISI marked as approved in the existing MCB DB complete with connections.

25

41025

1641

... More
Supplying and fixing 40Amps DP 240 volts, RCCB,300mA Legrand/L&T/Siemens make or any other reputad equevallent A catagories make ISI marked as approved in the existing MCB DB complete with connections.

29

54404

1876

... More
Supplying and fixing 63Amps DP 240 volts, RCCB,300mA Legrand/L&T/Siemens make or any other reputad equevallent A catagories make ISI marked as approved in the existing MCB DB complete with connections.

10

21680

2168

... More
Supplying and fixing 63Amps TPN 415 volts, RCCB,300mA Legrand/L&T/Siemens make or any other reputad equevallent A catagories make ISI marked as approved in the existing MCB DB complete with connections.(for power BDB & AC ODU)

18

46044

2558

... More
EARTHING INSTALLATION

1

-

-

... More
S/IT/C Of Earthing with copper earth plate 600 mm x 600mm x 6 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc (WITH charcoal and salt) as required.

10

129550

12955

... More
S/IT/C of materials and installation of pipe earth electrode made out of 50mm dia class B G.I. pipe of 3.0 metre long with arrangements for fitting/ termination of G.I. flat / wire with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge.

10

21240

2124

... More
Excavation of all kinds of soil up to 3 meters depth incluiding refilling (Except rocky soil )

8

1184

148

... More
Providing and fixing 4 mm dia copper wire on surface or in recess for loop earthing as required.

655

34715

53

... More
Providing and fixing 25mm x 5 mm copper strip on surface or in recess for connections etc. as required.

222

108114

487

... More
Refilling/Back filling soft soil with borrowed within a lead of 5 K.M. etc. as required.

10

987

98.7

... More
Excavation of all types of soil up to 3 meters depth including getting out the excavated soil disposal of the excavated soil as directed with lead of 50 meters.

10

1480

148

... More
Supplying and making brick massonary pedastal with extra super structure including cement plastering etc as required.

5

11000

2200

... More
CABLING AND END TERMINATION MAIN AREA: Supplying and laying of one number PVC insulated armoured and PVC sheathed AL. conductor power cable of 1.1 KV grade POLYCAB/FINOLEX/HAVELLS of following size cables with in different types laying.

1

-

-

... More
2 core x 4 sq mm (surface)(for BUILDING FOCUS LIGHT,event,cove light)

255

27540

108

... More
3.5core x 300 sq mm (under ground including excavation & refilling)(500KVA S.S TO MAIN PANEL DOUBLE RUN/DG SET TO MAIN PANEL)

111

184038

1658

... More
3.5core x 185 sq mm (under ground including excavation & refilling)(MAIN PANEL TO AC PANEL/UPS MAIN INCOMMER)

98

102900

1050

... More
3.5core x 150 sq mm (under ground including excavation & refilling

88

75328

856

... More
3.5core x 300 sq mm (in pipe,including supply of pipe) PANEL

31

47709

1539

... More
3.5core x 185 sq mm (in pipe,including supply of pipe)

15

15150

1010

... More
3.5 core x 300sq mm (open duct)

70

107170

1531

... More
3.5 core x 185sq mm (open duct)

21

21042

1002

... More
3.5 core x 150 sq mm (open duct)

22

17776

808

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following mentioned size cable.

1

-

-

... More
3.5 core x300 sq mm

16

11584

724

... More
3.5 core x185 sq mm

12

5820

485

... More
3.5 core x150 sq mm

13

5525

425

... More
Providing,fixing and laying of fallowing dia G.I. pipe (medium class) in ground complete with G.I fitting incl. trenching(75 mm depth)and refilling.

1

-

-

... More
50 mm dia

33

12804

388

... More
80 mm dia

21

9072

432

... More
150 MM dia

21

11949

569

... More
PANELS & CABLES

1

-

-

... More
FLOOR LIGHT PANEL (GF-10F)01 NOS IN EACH FLOOR LIGHT/ESSENTIAL POWER AND LIFT PANEL S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & pented by simens gray powder cote paint is designed as G.A drawing. Incommer- 01 number of 32A 4P MCB. (make- L&T/LEGRAND or equivalent reputed make ISI marked)(Icu=100 In)(.with axulary for BMS Busbar- 04 numbers of 60Amps Electrolytic copper busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. Out going- (i) 20A 4P MCB 01 NOS FOR POWER BDB/LIGHT BDB(Legrand make) Out going- (ii) 04 nos 25A DP MCB SPARE. Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse. (ii) 01 set of 0-30Amps Ameter with selecter switch & CTS.(DIGITAL) (iii) 01 set of 0-500 voltmeter with selecter switch.(DIGITAL)

9

208449

23161

... More
FLOOR POWER PANEL (GF-10F)01 NO IN EACH FLOOR ,FOR WATER SUPPLY 02 NOS S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & pented by simens gray powder cote paint is designed as G.A drawing. In commer- 01 number of 125 Amps 3P MCCB. (make- L&T/LEGRAND or equivalent reputed make ISI marked)(Icu=0.8 In)with shunt trip.with axulary for BMS Busbar- 04 numbers of 150Amps Electrolytic copper busbar duly sleeved by color coaded PVC sleeve & supported by suitable size DMC insulator. Out going- (i) 40A 4P MCB 02 NOS FOR POWER BDB (Legrand make) Out going- (ii) 04 nos 32A 4P MCB POWER SPN BDB Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse. (ii) 01 set of 0-100Amps Ameter with selecter switch & CTS.(DIGITAL) (iii) 01 set of 0-500 voltmeter with selecter switch.(DIGITAL)

9

628749

69861

... More
FLOOR UPS PANEL MINOR AREA LIGHT S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & pented by simens gray powder cote paint is designed as G.A drawing. In commer- 01 number of 32 Amps 4P MCB. (make- L&T/LEGRAND or equivalent reputed make ISI marked) Busbar- 04 numbers of 40Amps Electrolytic copper busbar duly sleeved by color coaded PVC sleeve & supported by suitable size DMC insulator. Out going- (i) 25A 2P MCB 04 NOS FOR LIGHT BDB(Legrand make) Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse. (ii) 01 set of 0-30Amps Ameter with selecter switch & CTS.(DIGITAL) (iii) 01 set of 0-500 voltmeter with selecter switch.(DIGITAL)

9

191448

21272

... More
FLOOR UPS PANEL FOR DATA CENTER OF ALL 50 KVA UPS S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. (FOR ALL MAIN CONNECTED LOAD) In commer- 02 numbers of 125 Amps 4P MCCB. (make- L&T/LEGRAND or equivalent reputed make ISI marked)(Icu=100% Isc) with shunt trip & axulary for BMS & mechnical inter locking for one incommer source to other. Busbar- 04 numbers of 150Amps Electrolytic copper busbar duly sleeved by color coded PVC sleeve & supported by suitable size DMC insulator. Out going- 02 nos 32A 4P MCB UPS RAW POWER Out going- 08 nos 32A DP MCB to Each rack power. Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse. (ii) 01 set of 0-100Amps Ameter with selecter switch & CTS.(DIGITAL) (iii) 01 set of 0-500 voltmeter with selecter switch.(DIGITAL) NB- This panel should have proper earth by suitable rated copper flat.

5

494120

98824

... More
MAIN UPS PANEL (100) KVA 2 NOS ON LINE UPS 3PH-3PH)AT GF control room S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & pented by simens gray powder cote paint is designed as G.A drawing. (FOR COMMON) In commer-01- 03 number of 200A,ICU=0.8 In 4P TYPE,MCCB (make- L&T,Equvalant reputed make ISI marked) .With axulary for BMS.(From 100 KVA UPS) Busbar-1- 04 numbers of 02 SETS 300Amps Electrolytic copper busbar duly sleeved by color coaded PVC sleeve & supported by suitable size DMC insulator. Out going-1- (i) 03 numbers of 125A 4P MCCB(DSINE) (make- L&T or equivalent reputed make ISI marked)(Each data rack) with bus bar system. Out going-2- (i) 08 nos 32A TPN MCB for normal light . Instrument- (i) 09 numbers phase indicating lamp with toggle switch & HRC fuse. (ii) 03 set of 0-200Amps Ameter with selecter switch & CTS.DIGITAL (iii) 03 set of 0-500 voltmeter with selecter switch.DIGITAL iv) 04 nos 40kA SP VSD with 32A SP MCB. NB- This panel should have proper earth by suitable rated copper flat.

1

172952

172952

... More
MAIN AC PANEL FOR OUTDOOR UNIT S/I/T&Commissioning of LT OUTDOOR mounted on roof top area with IP-65 PROTECTION floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & pented by simens gray powder cote paint is designed as G.A drawing. In commer- 01 number of 800A 3P MCCB with under voltage,over voltage ,current,earth fault protection (make- L&T,Equivalant reputed make ISI marked) Busbar- 04 numbers of 900Amps Electrolytic copper busbar duly sleeved by color coaded PVC sleeve & supported by suitable size DMC insulator. Out going- (i) 63A 4P RCCB,100MA 18 NOS FOR OUT DOOR UNIT UPTO 30 KW(Legrand make) Out going- (i) 32A 4P RCCB,100mA 14 NOS FOR OUT DOOR UNIT UPTO 15 KW (Legrand make) Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse. (ii) 01 set of digital type multifunction meter with CT for voltage,current,frequency,PF,THD indication (iii) 04 nos of 65kA SP VSD WITH 32A SP MCB

1

360961

360961

... More
MAIN CONTROL PANEL AT GF WITH BUSCOUPLING SYSTEM

1

-

-

... More
S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & pented by simens gray powder cote paint is designed as G.A drawing. (FOR 02 NOS OF 500 KVA TRANSFORMER) In commer(500 KVA NORMAL SUPPLY)-1- 01 number of 4p 800A EDO TYPE ACB(SR 18G) with under voltage,over voltage ,current,earth fault protection & Electrical locking for normal & DG (make- L&T/ABB/LEGRAND,Equivalent reputed make ISI marked) (WITH AXULARY FOR BMS) In commer(500KVA NORMAL SUPPLY)-2- 01 number of 800A 4p EDO TYPE ACB(630A SATING)(SR 18G) with under voltage,over voltage ,current,earth fault protection & Electrical locking for normal & DG(make- L&T,/ABB/LEGRANDEquvalant reputed make ISI marked) (WITH AXULARY FOR BMS) DG IN commer(320 KVA DG SUPPLY)-1- 01 number of 800A EDO TYPE 4p ACB(630A SATING)(SR 18G) with under voltage,over voltage ,current,earth fault protection & Electrical locking for normal & DG (make- L&T/ABB/LEGRAND,Equvalant reputed make ISI marked) (WITH AXULARY FOR BMS) DG IN commer(320 KVA DG SUPPLY)-2- 01 number of 800A EDO TYPE 4p ACB (630A SATING)(SR 18G) with under voltage,over voltage ,current,earth fault protection & Electrical locking for normal & DG (make- L&T/ABB/LEGRAND,Equvalant reputed make ISI marked) (WITH AXULARY FOR BMS) BUSCOUPLER-1(NORMAL 1&2 TO DG-1 & DG2)-1- 02 number of 1000A EDO TYPE ACB 4p(SR 18G) with under voltage,over voltage ,current,earth fault protection & Electrical locking for normal & DG (make- L&T/ABB/LEGRAND,Equvalant reputed make ISI marked) (WITH AXULARY FOR BMS) BUSCOUPLER-2(BUS-1 TO BUS-2)-2- 01 number of 1250A EDO TYPE 4p ACB(SR 18G) with under voltage,over voltage ,current,earth fault protection & Electrical locking for normal & DG (make- L&T/ABB/LEGRAND,Equvalant reputed make ISI marked) (WITH AXULARY FOR BMS) Busbar-1&2 04 numbers of 1000Amps Electrolytic copper busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing) Busbar-3&4 04 numbers of 1000Amps Electrolytic copper busbar duly sleeved by color coated PVC sleeve & supported by suitable size DMC insulator. (for outgoing) Out going- (i) 01 numbers of 400A 4P MCCB (make- L&T or equivalent reputed make ISI marked)(UPS INCOMMER & EQUIPEMENT PANEL) Out going- (i) 04 numbers of 63A 4P MCB (make- L&T or equivalent reputed make ISI marked)(timer panel & water supply management) out going- 01 number of 800A TP MCCB WITH ROM & S. LINK(make- L&T,Equvalant reputed make ISI marked) AC PANEL INCOMMER Out going- 02 numbers of 250A 3P MCCB (make- L&T or equivalent reputed make ISI marked)(FIRE PANEL & SPARE) Out going- 02 numbers of 630A 3P MCCB (make- L&T or equivalent reputed make ISI marked)(500 KVAR APFC PANEL 01 NO & 01 NO of PRESSION ac main incommer) Out going- 18 numbers of 125A 3P MCCB (make- L&T or equivalent reputed make ISI marked)(LIFT,WATER,FLOOR POWER & 05 NOS 50 KVA UPS) Out going- 02 numbers of 200A 4P MCCB (make- L&T or equivalent reputed make ISI marked)(02 NOS 100 KVA UPS) Out going- 15 numbers of 32A 4P MCB (make- L&T or equivalent reputed make ISI marked)(FDB LIGHT EACH FLOOR & AREA LIGHTING) Out going- 01 number of 250A 3P MCCB (make- L&T or equivalent reputed make ISI marked)(FOR SOLAR ) Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse. (ii) 01 set of digital type multifunction meter with CT for voltage,current,frequency,PF,THD indication (iii) 16 nos of 65kA SP VSD WITH 32A SP MCB

1

2378815

2378815

... More
In commer(500 KVA NORMAL SUPPLY)-1- 01 number of 4p 800A EDO TYPE ACB(SR 18G) with under voltage,over voltage ,current,earth fault protection & Electrical locking for normal & DG (make- L&T/ABB/LEGRAND,Equivalent reputed make ISI marked) (WITH AXULARY FOR BMS)

1

-

-

... More
500 KVAR APFC PANEL =01 NOS Supply ,installation ,testing & commissioning of 300KVAR APFC PANEL with contactor based switch ,main incommer MCCB,WITH LTXL ULTRA HEAVY DYTY power capacitor with 7% harmonic filter with copper reactor (stage-100+25+25+25+25+50+100+50+20+20+20+40(f)) of L&T/ABB /Siemens make) with all required accessories to complete the job including all connection.

1

422900

422900

... More
PRECESION AC CONTROL PANEL(2F) S/I/T&Commissioning of LT INDOOR mounted on Floor panel room with IP-55 PROTECTION floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & pented by simens gray powder cote paint is designed as G.A drawing. In commer- 01 number of 630A 3P MCCB with under voltage,over voltage ,current,earth fault protection (make- L&T,Equivalant reputed make ISI marked) Busbar- 04 numbers of 700Amps Electrolytic copper busbar duly sleeved by color coaded PVC sleeve & supported by suitable size DMC insulator. Out going- (i) 10 Nos of 100A 4P MCCB (25KA) (60-80%) (Legrand/L&T make) Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse. (ii) 01 set of digital type multifunction meter with CT for voltage,current,frequency,PF,THD indication (iii) 04 nos of 40kA SP VSD WITH 32A SP MCB

1

278456

278456

... More
CABLING AND END TERMINATION INTERNAL SUB AREA

1

-

-

... More
Supplying and laying of one number PVC insulated armoured and PVC sheathed AL. conductor power cable of 1.1 KV grade POLYCAB/FINOLEX/HAVELLS of following size cables with in different types laying.

1

-

-

... More
4core x 16 sq mm (surface)(MDB TO FDBL/FDBU SUB)

275

60500

220

... More
3.5core x 70 sq mm (surface)( POWER supply to FLOOR PANEL )

200

106000

530

... More
2 core x 4 sq mm (surface)(for BUILDING FOCUS LIGHT)

10

1080

108

... More
3.5core x 70sq mm (OPEN DUCT)(To FLOOR PANEL)

50

23250

465

... More
4 core x 16 sq mm (open duct)

50

9300

186

... More
3.5core x 35 sq mm (OPEN DUCT)(To pression AC POWER FOR IDU/ODU)

122

29280

240

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following mentioned size cable.

1

-

-

... More
4 core x16sq mm

20

2980

149

... More
3.5 core x70 sq mm

35

10430

298

... More
3.5 core x35 sq mm

22

5126

233

... More
Providing,fixing and laying of fallowing dia G.I. pipe (medium class) in ground complete with G.I fitting incl. trenching(75 mm depth)and refilling.

1

-

-

... More
50 mm dia

33

12804

388

... More
80 mm dia

33

14256

432

... More
UPS SYSTEM

1

-

-

... More
Supply ,installation ,testing & commissioning of 50KVA ON LINE UPS SYSTEM WITH suitable size battery bank, rated of battery & isolation transformer IGBT based inverter system of 3ph in put to 3 ph output,415V,protection for fault by OL,UV,EF,GF,OC of Schneider/ GE/ Liebert/Emersion make) including supply of rack inverter stand with sufficient backup upto 30 minutes with all required accessories to complete the job including all connection.(FOR DATA CENTER RACK)(05 NOS FOR DIFFRENT RACK )

5

3277365

655473

... More
Supply ,installation ,testing & commissioning of 100KVA ON LINE UPS SYSTEM WITH suitable size battery bank, rated of battery & isolation transformer IGBT based inverter system of 3ph in put to 3 ph output,415V,protection for fault by OL,UV,EF,GF,OC of Schneider/GE/ Liebert/ Emersion make) including supply of rack inverter stand with sufficient backup upto 30 minutes with all required accessories to complete the job including all connection.LIGHT & SPARE 100KVA)

2

2711314

1355657

... More
D.G. SET: WITH WIRING

1

-

-

... More
Supplying, Installation, Testing & Commissioning of Diesel Generating set (Alternator directly couple to Diesel Engine Salient type) compelete inspection by concerned electrical inspector with proper testing certificate complete in all respect broadly comprising of following and as per specification enclosed. (kirloskar/jackson/sterling make) ALTERNATOR:320 KVA Self excited, Brush less type, 3 Phase, 415 Volts 50 Hz, 4 Pole, AC Alternator complete with all accessories. ENGINE: Water Cooled Diesel Engine with rated capacity of 750 BHP at 1500 RPM; Turbo charged, direct injection type, 4 Stroke, 6 Cylinder including Fuel Tank of min. 300 liters capacity fabricated with 3 mm thick MS Sheet duly calibrated and painted with One coat of Primer & two coats of synthetic enameled paint of approved colour, residential type silencer with exhaust pipe 150 mm dia MS Pipe duly wrapped with asbestos rope of legging of specified qualtiy & specification. AMF PANEL: Cubical, Compartmentalized, AMF Panel Baord with all Power & Control Contractors, Switches, Meters and other accessories, Internal Wiring, connection, inter-connection etc. for Trouble Free smooth function for 320 KVA DG Set complete with Battery Charger & leads as required. BASE PLATE: Common Base Plate of required size for mounting of Engine Alternator Set fabricated from MS Channerl and vibration damping arrangement with cushy foor mounting including paintng etc. as required. FOUNDATION: Suitable size Cement Concrete (1:2:4) foundation duly plastered and finished with neat coat Cement as required.

2

5058926

2529463

... More
13 PASSENGER LIFT WITH WIRRING

4

10347600

2586900

... More
Design Supply, Installation, Testing & Commissioning and putting into operation with compelete inspection by concerned electrical inspector, Director Factory and Boilers, Odisha with proper testing certificate and final testing of Automatic Lift compelte with all standard equipments accessories and control equipments as per Manufacturer's Design and as per CPWD /OPWD specification (Part - III Lifts) 1981 with valid lisence for installation and fulfilling following requirements on turnkey basis. Type: PASSENGER LIFT Load: 13 PASSENGER(884 KG) Speed: 1-1.25 Meter Per Second. Control: Variable voltage with variable frequency Operation: Microsprocessor based simplex collective selective with / without Lift Attendant. Total Rise: About 45.3 Meters. Landings: For All on same side. Floors Served: BF,G, 1,2,3,4,5,6,7,8,9,TERRACE Signals: Digital Car Position Indicator, Car Travel direction Indicator in Car & at all Landings. Lift Shaft Size: About 2600 mm Width X 1900 mm Depth, finished with Plaster. Lift Car Size: About 2000 mm Width X 1100 mm Depth. Car Entrance: Clear Opening 900 mm Wide X 2000 mm high Protected with Car Door. Landing Entrance: Clear Opening 900 mm Wide X 2000 mm high Protected with Landing Door. Car Door: Stainless with front glass to transparent Two Panel Center opening flush type.outer visible. Landing Door: Mild Steel Two Panel Center opening flush type P. Door Operation: Automatic Electric Power operated Door with in infrared protection. Car Interior: Stainless Steel Panel with Hair line finish on all sides. Car Floor: Hard Wood covered with PVC / Marblex Tiles.

1

-

-

... More
Car Ceiling & Lighting: Fluorescent Lighting Concealed by suspended false ceiling with plain acrylic diffiuser. The frame of suspended false ceiling shall be of powder coated Aluminum. Car Ventilation: Pressure Fan with anodized Aluminum Grill. Emergencing Lighting in Car: Battery operated Emergencing Lighting in the Lift Car. Intercom System: Battery operated intercom system in Lift Car, Machine Room and Control Room. Emergencing Alarm: Battery operated Alarm Bell System in Lift Car and Control Room. Position of Machine Room: Directly above the Lift Shaft.Electric Power Supply: AC 415 Volt 3 Phase 50 Hz terminated in Machine Room. OTHER SPECIAL PROVISIONS • VVVF CONTROLLER • AUTOMATICE RESCUE DEVICE (ARD) • EMERGENCY LIGHT AND BATARY OPERATED ALARAM BELL • DOT MATRICKX SEVEN SIGMENT DIGITAL POSITION INDICATORS • FIRE RATED DOOR FOR 1 HOUR • 3 WAY INTER COM/PRESS AND SPEAK BUTTON WITH HAND SET • FLOOR ANNUNCIATOR WITH MUSIC • INFRA RED SCREEN • OVER LOAD WARNING INDICATOR • BRAILLE BUTTONS • FREE SERVICE FOR 2 YEARS • PIT LADER • FULL CAR HEIGH CAR FIXTURE ARRIVAL CHIME • PROVISION FOR CC CEMARA WITH INSTRUEMENT Fire Man Switch: Fire Man Switch at Main Landing Terminal.

1

-

-

... More
CABLE TRAY /RACE WAY FOR DISTRIBUTION OF POWER

1

-

-

... More
HOT DIPP GALVANIZED(GC) AS PER EN-ISO-1461 , CARBON STEEL WIRE MESH CABLE TRAYS with internal dimensions of size 54mm(H) x 200mm(W), of Legrand - Cablofil make or equievalant reputed make ISI marked as approved .The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications.(With all accessories,bend,cover,supporter)WITH REQUIRED SIZED JUNCTION BOX ,COVER CONNECTOR as required.

155

92225

595

... More
HOT DIPP GALVANIZED(GC) AS PER EN-ISO-1461 , CARBON STEEL WIRE MESH CABLE TRAYS with internal dimensions of size 54mm(H) x 300mm(W), of Legrand - Cablofil make or equievalant reputed make ISI marked as approved .The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications.(With all accessories,bend,cover,supporter)WITH REQUIRED SIZED JUNCTION BOX ,COVER CONNECTOR as required.

124

97712

788

... More
HOT DIPP GALVANIZED(GC) AS PER EN-ISO-1461 , CARBON STEEL WIRE MESH CABLE TRAYS with internal dimensions of size 54mm(H) x 400mm(W), of Legrand - Cablofil make or equievalant reputed make ISI marked as approved .The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications.(With all accessories,bend,cover,supporter)WITH REQUIRED SIZED JUNCTION BOX ,COVER CONNECTOR as required.

145

129050

890

... More
FLOOR RACE WAY SYSTEM

1

-

-

... More
HOT DIPP GALVANIZED(GC) AS PER EN-ISO-1461 , FLOOR RACE WAY WITH JUNCTION with internal dimensions of size 54mm(H) x 200mm(W), of Legrand - Cablofil make or equievalant reputed make ISI marked as approved .The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications.(With all accessories,bend,cover,supporter)WITH REQUIRED SIZED JUNCTION BOX ,COVER CONNECTOR as required.

120

106800

890

... More
HOT DIPP GALVANIZED(GC) AS PER EN-ISO-1461 , FLOOR RACE WAY WITH JUNCTION with internal dimensions of size 54mm(H) x 300mm(W), of Legrand - Cablofil make or equievalant reputed make ISI marked as approved .The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications.(With all accessories, bend, cover, supporter) WITH REQUIRED SIZED JUNCTION BOX ,COVER CONNECTOR as required.

128

117760

920

... More
EXTERNAL ELECTRICAL & STREET LIGHTING:

1

-

-

... More
Supplying, Erection, Fixing, connection & testing of LED Street Light of HAVELLS MODEL: ENDURAPEARLPLUSSL60WLED757PASYTOPC /PHILIPS /WIPRO MAKE or equvalant reputed make ISI marked as approved make with specification LED Luminarie 60 Watt with 9 meter Velmond make maintenance freeG.I POLE with braket including MCB box for inspection as required.

18

565974

31443

... More
Supplying, Erection, Fixing, connection & testing of LED BOUNDRY WALL Light of HAVELLS MODEL: ENDURAPEARLSL25WLED757SASYTOPC/WIPRO or equvalant reputed make ISI marked as approved make with specification LED Luminarie 25 Watt with BRAKET MOVEABLE TYPE maintenance free for inspection as required.

49

113386

2314

... More
S/IT/C of materials and installation of pipe earth electrode made out of 50mm dia class B G.I. pipe of 3.0 metre long with arrangements for fitting/ termination of G.I. flat / wire with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge.

15

31860

2124

... More
Excavation of all kinds of soil up to 3 meters depth incluiding refilling (Except rocky soil )

6

888

148

... More
Providing and fixing 4 mm dia copper wire on surface or in recess for loop earthing as required.

312

16536

53

... More
Providing and fixing 25mm x 5 mm copper strip on surface or in recess for connections etc. as required.

55

26785

487

... More
Refilling/Back filling soft soil with borrowed within a lead of 5 K.M. etc. as required.

11

1085

98.7

... More
Supplying and laying of one number PVC insulated armoured and PVC sheathed AL. conductor power cable of 1.1 KV grade POLYCAB/FINOLEX/HAVELLS of following size cables with in different types laying.

1

-

-

... More
4core x 10 sq mm (surface)(OFP TO IND. TIMER PANEL)

33

5313

161

... More
4core x 10 sq mm (surface)(TIMER PANEL TO POLE)

28

4508

161

... More
3.5core x 35 sq mm (under ground including excavation & refilling)

35

11900

340

... More
4 core x 10 sq mm (under ground including excavation & refilling)

55

18260

332

... More
3core x 4sq mm (open duct)

98

10584

108

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following mentioned size cable.

1

-

-

... More
3.5 core x35sq mm

8

2000

250

... More
Supplying,laying of 3cx2.5 sq.mm copper flexible cable with insulated cover of reputed make,ISI marked with all other concerned materials.

212

21836

103

... More
Providing,fixing and laying of following dia G.I. pipe (medium class) in ground complete with G.I fitting incl. trenching(75 mm depth)and refilling.

1

-

-

... More
50 mm dia

18

6984

388

... More
150 MM dia

18

19800

1100

... More
PANELS: S/I/T&Commissioning of LT OUT DOOR FLOOR mounted cubical type MCB ENCLOSURE made out by 2mm CRCA steel sheet duly derusted & pented by simens gray powder cote paint is designed as G.A drawing. (FOR UPS) with 20A TPN MCB 01 NO.

4

8176

2044

... More
AREA LIGHT,TIMER PANEL FOR STREET LIGHT & HIGH MAST LIGHT S/I/T&Commissioning of LT OUTdoor WALL/FLOOR mounted double door type cubical type electrical main panel ( light ) made out by 2mm CRCA steel sheet duly derusted & pented by simens gray powder cote paint is designed as G.A drawing. In commer- 01 number of 32A 4P MCB. (make- LEGRAND or equivalent reputed make ISI marked) Busbar- 04 numbers of 40Amps Electrolytic copper busbar duly sleeved by color coaded PVC sleeve & supported by suitable size DMC insulator. Out going- (i) 01 number TIME SWITCH,01 NO OF 32A TP POWER CONTACTOR FALLOWED BY, 6-32A SP MCB-15 NOS((make- Legrand or equivalent reputed make ISI marked)(FOR OUT LIGHT CIRCUIT) Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse. (ii) 01 set of 0-30Amps Ameter with selecter switch & CTS. (iii) 01 set of 0-500 voltmeter with selecter switch.

3

66516

22172

... More
AIR TERMINAL & ACCESSORRIES LIGHTNING ARRESTER+ MAST: Supply and Fixing of GI Mast (3//5 mtrs height) for mounting the terminal & adaptor with the Stormaster ESE air terminal along with supporting stay wires, etc .Make : ABB/Precision Power PTY Ltd(MODEL OPR 60+MAST 3M,ABB MAKE)

2

303000

151500

... More
Supply of 70 sq.mm pvc insulated flexible single core copper down conductor along with the fixing accessories for ESE lightning arrestor. Make : Polycab/Finolex/RR Cable

212

138224

652

... More
Lightning Strike recorder (LSR): LSR should me non electronic and non-resettable type having 06 digits Display and enclosed in an IP 67 enclosure with the minimum sensitivity of 1000 A & maximum capacity of 220 KA tested on 8/20 microsec wave form as per IEC 60-1:1989. It should be non electronic type and does not required external powersupply for the working. Model: LS COUNTER ( Optional) Make : ABB OR EQUIEVALANT

2

71200

35600

... More
(i)Code No. MES – 80 (3. Mtrs) Maintenance free Safe Earthing Electrodes with ISI G.I. pipe dia 75mm as Secondary electrode with wall thickness of 2.6 mm and the Primary Earthing Electrode will be 50mm X 6mm X 1no M.S. hot dipped galvanized strip filled with a highly conductive & non-corrosive compound in between the Primary Earthing and the secondary Earthing, the Surface Area in will be 7,06,500sqmm for 3mtrs length and Cross Sectional Primary conducting area is 300 sq.mm. An Solid G.I. Base plat seals the unit at the bottom. (MES-GFC ground Filling compound will be provided in 25 kgs Bags.)(MES-GFC ground Filling compound will be provided in 25 kgs Bags.)(2 bags required for each earthing electrode.)

4

74000

18500

... More
2 X 500KVA SUBSTATION

1

-

-

... More
Supplying & installation of 100x116 mm RS Joist, 9 mtr long x 2 nosx23 Kg=414 Kg

755

61155

81

... More
Supplying & installation of Pressure Channel 100 x 50 x 6mm MS channel each 2.8 mtr. Long( 9.2 K.g. per mtr.)x2 Nos

288

25632

89

... More
Supplying & installation of S/S 2 Pole bressing chhanel 75 x 40 x 6mm MS channel each 2.8 mtr. Long( 6.8 K.g. per mtr.)x2 Nos

268

23852

89

... More
Supplying & installation of AB Swith & HG Fuse, Mounting Channel 75x40x6 -2.8 mtr.long, 4 nos.(6.8K.g. per mtr.)

135

12015

89

... More
Supplying & installation of Cantilever chhanel for supporting AB Switch arm, 75x40x6-1 mtr. Long, 2 nos.(6.8 K.g. per mtr.)

139.5

12415

89

... More
Contilever chhanel for supporting HG Fuse 50 x 50 x 6 mm MS Angel (1.0 mtrs. Long 2 nos.)4.5K.g. per mtr.

188

16732

89

... More
Supplying & installation of Angle for Cantilever arrrangement for AB Switch & HG Fuse 50 x 50 x 6 -2 mtr .each 2 nos.(4.5 K.g. per mtr.)

255

22695

89

... More
Supplying & installation of S/S 2P bressing Angle 50 x 50 x 6 mm - 2.8 mtr. Long 2 nos.(4.5 K.g. per mtr.) with side angel ( Total 9 mtr.)

298

26522

89

... More
Supplying & installation of Angle for mounting LT distribution Box 50 x 50 x 6 mm MS Angel -2.5 mtrs.each Long 2 nos.( 4.5 K.g. per mtr.)

358

31862

89

... More
Supplying & installation of 11KV AB Switch 3 Pole (1000 Amp.)

2

47246

23623

... More
Supplying & installation of 11KV HG Fuse 3 Pole (800Amp.)

2

30156

15078

... More
Supplying & installation of11 KV L.A. 12KV-10KA

6

22176

3696

... More
Supplying & installation of+B7 H.T.stay set ( Complete )

8

17736

2217

... More
Supplying & installation of H.T. Stay Insulator

8

2368

296

... More
Supplying & installation of H.T. Stay clamp (1.95 K.g./ Pair )

8

1872

234

... More
Supplying & installation of 7/10 SWG Stay Wire

123

13653

111

... More
Supplying & installation of of materials and installation of pipe earth electrode made out of 50mm dia class B G.I. pipe of 3.0 metre long with arrangements for fitting/ termination of G.I. flat / wire with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge.

20

112340

5617

... More
Supplying & installation of 25X5 MM G.I STRIP

133

13566

102

... More
Supplying & installation of 40x6mm GI Flat for nutral

78

6942

89

... More
Fixing of stay set with 0.5Cum cement concret foundation 1:3:6 size ( 900mmx600mmx900mm) using 40mm BHG metal with all labour and material except stay set , stay wire , stay insulator .

12

31116

2593

... More
Concreting of support C.C - 1:4:8 using 40mm BHG metal size - 5'x2'x2' = 20CFT = 0.570Cum Padding 900x600x150mm = 0.081 0.651Cum @ 3071.25= 1999.38 each

15

44340

2956

... More
Couping of support section 15''x15'' ( 3.9Cft) height 2'-6' ( 1' - 6'' above G.L & 1' - 0' below G.L ) in C.C 1:2:4 using 12mm BHG metal & curing for 5 days

15

11355

757

... More
Supplying & installation of Materials for Machinery work for Earth Pit,Charcoal, Salt etc including construction of earthing chamber (Size: 2"x2") and RCC slab cover

25

63550

2542

... More
Supplying and Laying of HT cable on existing pole 3cx240 sq. mm XLPE cable.,11kv ,2 runs For 500KVA

120

329040

2742

... More
Supplying and making out door end termination with cast resin compound aluminium lugs and other jointing materials for 3cx240 sq.mm size of PVC insulated armoured and PVC sheathed aluminium conductor cable of 1.1 KV grade as required.

8

218784

27348

... More
Supplying & installation of 50x6mm copper Z clamp for TFR LT 4nos x0.8kg each for connection of LT cable

125

155250

1242

... More
Supplying & installation of Red Oxide paint

50

6300

126

... More
All. Paint for painting of pole & transformer.

50

7000

140

... More
Black Paint for painting of angle & channel.

50

6300

126

... More
Supplying & installation ,fixing of Ms Nut , Bolt & Washer

285

31635

111

... More
Supply, erection , testing and commissioning of 500KVA 11000V / 433V, 3 phase 50 Hz, copper winding Delta-Star, Dyn11, Step-down, Cast Resin- Oil cooled type Transformer with On load tap changer from +10% to -15% in steps of 1.56%. with compelete inspection by concerned electrical inspector with proper testing certificate Cable termination box on HT and LT side. 1 no. CT ,class PS duly fitted and connected shall be provided for the neutral. Neutral shall be solidly earthed. The indications for the bucholz's relay, oil temperature, winding temperature, alarm to be indicated in the Main LT panel respectively. The transfromer shall be suitable for connecting sandwich type busduct from Main LT panel.

2

1097926

548963

... More
Supplying & installation of 100x116mm RS Joist 4mtr longx23kg for resting of LT cable

255

20655

81

... More
Construction of Plinth for TFR 6ft hight (below GL4ft)x10ftx0ft

1

44348

44348

... More
Barbed Fencing (size 15'x15' )with constn. of retaining wall ,erection of RCC fencing post, Sand filling and metal spreading, Fixing of Iron gril gate etc as per CESU specification

6

325956

54326

... More
Providing and fixing 25mm x 5 mm G.I strip on surface or in recess for connections etc. as required.

121

15730

130

... More
Sundries for survey , PVC tape, Ampire tape,Danger Board, small size nut & Bolt preparation of drawing cable socket etc

2

29566

14783

... More
Charges of Electrical distribution department with their leassoning charges ,inspection charges for departmental engineer-in charge with all type of testing whichever required for substation area ,charging of substion with tested ok etc as required to complete the job with supplying and installation of HT/ CT opprated type KWH metering system with 1000/5A CT range as per direction of Engg.-in-charge of concerned electricity supply company having provission for HT Measurement panel if necessary to complete the job as required.

1

355000

355000

... More
Security deposit for total maximum demand of office building which is chargeble from concerned elect. Dept (CESU) with all duties and also refundable . (@ Rs 4000.00/Kwt)

1

4000

4000

... More
Supervission charges for construction of o 11 KV HT OH line & LT destribution charges ,maintainance charges . (@6% of total sum of estimated cost for SUB STATION DETAIL ESTIMATE)

1

51400

51400

... More
SUBSTATION EQUIPMENTS: A. FP STRUCTURE

1

-

-

... More
Supply, installation & commissioing of 12KV outdoor FP structure and associated equipments with a set of Air break switch,a set of GOS operating handle,a set of lightning arrestors, DOLO fuses,insulators 0 swg cu wires,Alkathene tube and other necessary accessories as per local Electricity Board requirement., cross arms for cable pot head including jumper with support arrangement for cable riser to be included. .The rate shall be inclusive of foundation for poles all as per specification (4 Nos. 9.15 mtr long RSJ pole)

1

-

-

... More
Supply

1

263500

263500

... More
Installation

1

27800

27800

... More
HT METERING CUBICLE: Supply Installation, testing and commissioning of Central Electricty supply utility of orissa (CESU) certified outdoor 12KV Tariff Metering panel as per departmental technical specification.

1

-

-

... More
Supply

1

200000

200000

... More
Installation

1

20000

20000

... More
H.T VCB PANEL: Supply, installation, testing and commissioning of CESU certified H.T Breaker panel- outdoor VCB KIOSK extensible type for future requirement. The Panel shall be made out of 2.5mm cold rolled, mild steel, metal clad, free standing, totally enclosed, cubical type and compartmentalised suitable for operation on 12kV, 3phase, 50Hz, AC earthed system with busbar interconnections, control wiring, designation labels, Caution notices, pad locking facilities wherever required. Necessary space provision for entry of HT cables from the bottom through detachable gland plates.The Panel shall be finished with one coat of Air drying Epoxy primer and two coats of Epoxy paints of shade 631 0f IS:5Siemens Grey paint finish.

1

-

-

... More
Supply

1

655800

655800

... More
Installation

1

25000

25000

... More
CONTROL CABLES (COPPER) Supply, laying and testing of 1.1KV grade PVC insulated copper cables (YFY) as per specification. The rates quoted shall be for laying in trays, cable trenches (indoor and outdoor), pipes, etc. For buried cables, the are shall include excavation works for outdoor cable laying." "24 Core x 2.5 Sqmm Cable (PVC) Market rate"

80

240000

3000

... More
TERMINATION CONTROL CABLES (COPPER) Supplying and providing the end termination\s with copper lugs for all the above cables with Double compression brass cable glands, taping, crimping, gland and amour earthing, etc. complete as required. "24 Core x 2.5 Sqmm Cable (PVC) Market Rate"

4

12000

3000

... More
FENCING: Providing 2500mm high chain link fencing consisting of 50x50x6mm MS angle, vertical support, 2500mm high (space not exceeded 3M), 50x50x6mm MS angle 2800mm long bracing struts (in both directions) for every fifth post (andat change of directions of fence) and 8 guage chain link mesh 50x50mm fully streached and secured at MS angle verticals and horizontals with 6mm dia MS bolts, nuts and washers spaced at 150mm (min) using 25x5mm MS flat cover strips, 170mm long, bottom 75mm end of MS verticals and bracing struts to be split and 40mm embedded in 400x400x500 deep cement cencrete 1:3:6 including necessary welding and / or bolted connections of MS horizontals and bracing / struts to vertical posts excavation, cement concrete and painting one coat of primer and two coats of synthetic enamel paint to all exposed faces of steel work and chain link fencing, measurd nett area of fencing between external.

1

-

-

... More
Supply

20

100000

5000

... More
Installation

20

10000

500

... More
Supply and Installation of Gate for Substation along with Fencing, Frame size - 2.5M x 1.8M MS Angle - 50 x 6mm Chain Link - 8SWG GI Paint - 2coats of Red oxide & 2coats of enamel paint.

1

-

-

... More
Supply

1

15000

15000

... More
Installation

1

2000

2000

... More
Excavation of all types of soil up to 3 meters depth including getting out the excavated soil disposal of the excavated soil as directed with lead of 50 meters.

30

4440

148

... More
Providing and laying in position cement concerete 1:2:4 (1 Cement: 2 Coarse Sand: 4 graded stone aggregate 20mm nominal size) in foundation of pump, DG ste etc. including formwork etc as required including all cost, conveyance and royalty as per the direction of the EIC.

15

78287

5219.14

... More
Supplying,installation,testing and commissioning of SOLAR WATER HEATING SYSTEM with solar panel and suitable rated charge controller,CVT for constant output voltage for heater,all DC protection devicess ,including supplying ,fixing of charge controller, with all accessories including wirring and inter connection . ake-sukam/uniline

500

377500

755

... More
SOLAR PV WITH BATTERY BANK FOR EM. LIGHT Supplying, Erection, Fixing, connection & testing of 22 KW SOLAR PV with CHARGE CONTROLLER & INVERTER ,suitable size battery with bank (150Ah,12v 10 nos) including MCB box for inspection as required.(Govt. Approved make)

22

2090000

95000

1

-

-

... More
Design , Supply, Testing, Commissioning and obtaining statutory approval of approved Make Modular type VRV outdoor units equipped with highly energy efficient Scroll Compressors (ONLY) with all inverter compressor(s) with variable refrigerant temperature(VRT) technology, tensile strength of compressor body not less than 600 MPa having compressor motor of 6 pole , each outdoor unit have external static pressure not less than 78 Pa, special designed four faces heat exchanger, ODU dB level less than 65 at a distance 1 Meter, centrifugal fan for condenser, ODU having front suction & top discharge, Y-branch as required, outdoor unit support, auto check function for connection error, auto address setting, refrigerant cooled PCB circuit at ODU and capacity as mentioned below. VRV -X System shall be suitable for working on 49 °C ambient temperature, Refrigerant R 410A. with Powder coated MS Angle / Channel outdoor stand of suitable size to carry the weight of outdoor unit. The unit price shall be inclusive of full charge of Refrigerant Gas & Oil.(Cooling Only) Individual ODU Capacity not more than 20HP. Following are the ODU details.

1

-

-

... More
14 HP VRV X

2

406068

203034

... More
20 HP VRV X

2

557973

278986.5

... More
24 HP VRV X

1

360681

360681.75

... More
30 HP VRV X

2

870922

435461

... More
32 HP VRV X

7

3217669

459667

... More
36 HP VRV X

2

1020480

510240.25

... More
44 HP VRV X

3

1929934

643311.5

... More
46 HP VRV X

1

665912

665912

... More
50 HP VRV X

1

716485

716485.25

... More
52 HP VRV X

1

744396

744396.25

... More
54 HP VRV X

1

767058

767058.5

... More
58 HP VRV X

1

818681

818681.5

... More
IDU DETAILS: Design SITC Indoor Unit of approved make with Cordless Remote controller -VRV Round flow casstette type unit with inbuilt VRT technology.

1

-

-

... More
A. CASSETE AC UNIT

1

-

-

... More
0.75 TR Round Flow VRV Cassette AC with VRT

14

402990

28785

... More
1.00 TR Round Flow VRV Cassette AC With VRT

12

351576

29298

... More
1.65 TR Round Flow VRV Cassette AC with VRT

14

438102

31293

... More
2.0 TR Round Flow VRV Cassette AC with VRT

18

578664

32148

... More
2.6 TR Round Flow VRV Cassette AC with VRT

8

263568

32946

... More
3.0 TR Round Flow VRV Cassette AC with VRT

30

1090980

36366

... More
3.3 TR Round Flow VRV Cassette AC with VRT

9

333963

37107

... More
4.0 TR Round Flow VRV Cassette AC with VRT

25

944775

37791

... More
4.6 TR Round Flow VRV Cassette AC with VRT

28

1144332

40869

... More
B.Design SITC of DUCTABLE AC

1

-

-

... More
2.0 TR Ductable AC

6

190152

31692

... More
2.3 TR Ductable AC

10

380760

38076

... More
3.0 TR Ductable AC

2

80484

40242

... More
3.3 TR Ductable AC

2

80484

40242

... More
4.0 TR Ductable AC

2

84588

42294

... More
4.5 TR Ductable AC

1

50046

50046

... More
6.6 TR Ductable AC

8

567720

70965

... More
8.0 TR Ductable AC

6

448704

74784

... More
C.Design SITC of HI WALL SPLIT AC

1

-

-

... More
0.75 TR Hi Wall Split AC

1

21603

21603

... More
1.00 TR Hi Wall Split AC

2

44004

22002

... More
1.5 TR Hi Wall Split AC

3

72162

24054

... More
Design SITC of VRF new I-touch Manager controling HVAC system

1

125343

125343

... More
Design SITC of DOUBLE SKIN HORIZONTAL FLOOR MOUNTED AIR HANDLING UNITS of approved make. SITC of 9000 cfm24 TR

3

1098940

366313.56

... More
AHU ACCESSORIES: EEV KIT

6

119700

19950

... More
Communication Kit

6

17100

2850

... More
Wired Remote

6

10260

1710

... More
Design SITC of Y-Branches/ ODU Connector

204

775200

3800

... More
Design SITC of the Cu. refrigerant pipes with 19mm/13mm with nitrile rubber tube insulation of following sizes Gas line with 19mm thick insulation

1

-

-

... More
41.3mm

380

956216

2516.36

... More
34.9mm

365

762850

2090

... More
28.58mm

420

728574

1734.7

... More
22.2mm

260

371685

1429.56

... More
19.05mm

260

336908

1295.8

... More
15.88mm

630

753152

1195.48

... More
12.7mm

25

21375

855

... More
Liquid line with 13mm thick insulation

1

-

-

... More
19.05mm

645

814222

1262.36

... More
15.88mm

410

479864

1170.4

... More
12.7mm

360

394257

1095.16

... More
9.52mm

900

940500

1045

... More
6.35mm

25

19000

760

... More
Design, supply, fabrication & erection of air distribution GSS Ducting in accordance with the approved ducting lay out drawing, complete with all accessories, dampers, guide vanes, support, etc.

1

-

-

... More
24 G GP Sheet

2100

1645875

783.75

... More
22 G GP Sheet

1000

991860

991.86

... More
Design SITC of Acoustic insulation inside the SA Ducts with 12 mm thick F.G. & 36 G purported aluminium.

950

740354

779.32

... More
Design SITC of Providing insulation over the ducts with 13mm thick Aluminium foil faced nitrile fome insulation.

2150

1865942

867.88

... More
Design SITC of Providing & Connecting canvas in mouthpiece.

40

83245

2081.13

... More
Design SITC of approved make linear grills or extruded aluminium section finished with power coated or approved colour.

1

-

-

... More
Grill/Diffuser

150

1760116

11734.11

50

318813

6376.27

... More
Installation, testing and commisisoning of fire dampers including cost of material,labour and all sundries as per the direction of EIC.

90

1554216

17269.07

... More
Control & Transmission Wiring:Supply Installation Testing and Commission of Control wiring of 2 core x 1.5 sqmm copper in suitable conduits between indoor and outdoor units

3800

858116

225.82

... More
Supply Installation Testing and Commission of PVC drain pipe with 6mm thick nytrile tube insulation.

1

-

-

350

179770

513.63

130

75985

584.5

90

58980

655.34

... More
Design SITC of GI Slotted Tray for expose copper piping covered with GI sheet(22G) on terrace & in shaft if open.

1

-

-

... More
50mmx150mm X 50mm

30

29212

973.75

... More
50mmx300mm X 50mm

50

68633

1372.67

... More
Design Sitc of VRV systems including topping R410A gas as per site requirements

650

900932

1386.05

... More
Scaffolding, Out door unit base & Other miscelineous works

1

1771186

1771186

... More
Basement Ventilation: Design SITC of Vane Axial Fan with class H 300 Deg for 2 hrs Motor rating, for fire case you have to run both 66200 cfm axial fan with class H 300 Deg for 2 hrs Motor rating

1

-

-

... More
400 mm Dia model

5

331250

66250

... More
355 mm Dia model

9

569250

63250

... More
315 mm Dia model

15

888750

59250

... More
Lift & Stair case pressurization 40MM Static Direct driven Axial flow fan

1

-

-

... More
13000 CMH

3

204060

68020

... More
11000 CMH

1

63070

63070

... More
3400 CMH

2

85220

42610

... More
6500 CMH

3

142680

47560

... More
26000 CMH

1

82540

82540

... More
Design, Supply, installation, Testing & commissioning and statutory approval for Precision AC system along with accessories as per the following requirement :

1

-

-

... More
Supply of Floor Mounted, Downflow bottom discharge, Air Cooled DX type 10 TR ( 35KW) of sensible cooling capacity @ 10000 CMH Precision Air Conditioner units at Outdoor Ambient Condition @ 42 Deg C and inside room air tempareture of 22 deg C & 50% RH and with R-410 A Refrigerant Gas) & should work at part load (From 20% to 100%) with Variable Capacity digital scroll / Inverter compressor.

8

5520000

690000

... More
Installation & Commissioning considering IDU to ODU distance 20 mtr. Without grill.

8

1080000

135000

... More
True Floor insulation

1400

210000

150

... More
FIRE FIGHTING: A. FIRE PUMP ROOM EQUIPMENT

1

-

-

... More
Supply, erection, testing & commissioning of electrical motor driven main pump of horizontal centrifugal end suction backpull out type with gland packing and capable to deliver 2850LPM at 110MWC.The pump shall be coupled to TEFC motor of suitable HP with speed of 2900 RPM and complete set shall mounted on common base frame. The quoted rate shall includes providing & fixing of coupling, coupling gaurd,etc.Make-Kirloskar/Mather Platt

2

740000

370000

... More
Supply, installation, testing & commissioning of diesel Engine driven common stand by pump, horizontal centrifugal end suction backpull out type with gland packing and capable to deliver 2850LPM at 110MWC. The pump shall coupled to suitable HP of Diesel engine radiator water cooled type with speed of 1800RPM and complete set shall be mounted on common base frame. Batteries & battery leads with stand, Fuel tank ( for 6 Hrs. operation ) with stand & gauge glass, Fuel piping with valves. The quoted rate shall includes radiator water cooling piping(if reqired) coupling gaurd and other stanadrd accessories.Make-KSB/Kirloskar/Crompton Greaves/MatherPlatt

1

765800

765800

... More
Supply, erection, testing & commissioning of electrical motor driven Jockey pump of horizontal centrifugal end suction back pull out type with gland packing and capable to deliver 180LPM at 110MWC.The pump shall be coupled to TEFC motor of suitableHPwith speed of 2900RPM and complete set shall mounted on common base frame. The quoted rate shall includes providing & fixing of coupling, coupling gaurd etc.Make-KSB/Kirloskar/Crompton Greaves/MatherPlatt

2

246000

123000

... More
CONTROL PANEL FOR FIRE PUMPS: Fabricating & Supply, installing, testing and commissioning of compartmentalised common control panel for Electrical motor driven pumps and Diesel engine driven pumps.

1

438000

438000

... More
1100 V GRADE POWER / CONTROL CABLES: Supplying, laying, testing & commissioning of PVC outer sheateh, steel armoured, aluminium / copper conductor, 1100v grade power cables with glands etc.The cables shall be laid in tray / Hume pipe / in trenches/on walls/ floor etc. as required. For cables laid out door the rate shall exclude earth excavation providing brick and sand protection, refilling and compacting the earth.The minimum size of the cables shall as mentioned below,Make:Polycab/Gloster

1

76000

76000

... More
CABLE TRAY: Supplying and fixing of perforated G.I.sheet cable tray with neccessory angle iron suspension supports, anchor fasteners etc. complete. Maximum height of suspension shall not exceed 500 mm.Size of the tray shall be suitable for laying the above mentioned cables.

50

33000

660

... More
G.I. Earthing strips of 50mm x 6mm thick, strip shall be run on floor / ceiling / walls, from the equipment to the nearest Earth pit with neccessory accessories as required. ( Erath pit shall be executed by other agencies).

60

14700

245

... More
Supplying, installing, testing and commissioning of M.S. Pipes confirming to IS 1239 Pt - I Heavy grade with painting, suitable type of supports, anchor fasteners, bolts nuts, clamps, "U" bolt, malleable specials such as Reducers,Tees, elbows, flanges. Including cutting, Welding, fixing in / on walls, ceiling by using suitable supports etc, as per drawings. The quoted rate shall also include for chasing / chipping walls, making bore holes in walls / floor and making them good with filler material and finished in cement morter etc. complete.Make:Tata/Jindal

1

-

-

... More
250mm nominal dia

6

20100

3350

... More
200mm nominal dia

6

16680

2780

... More
150mm nominal dia

60

139920

2332

... More
80mm nominal dia

12

16440

1370

... More
Supplying, installing, testing and commissioning of ISI Mark Dual Plate Wafer Type Non-return valves ( PN 16) with required flanges, nuts, bolts and gaskets etc. complete.Make:Kartar/AIP/Veeson/CRI/Intervalve

1

-

-

... More
200 mm nominal dia for (2Elect+1Diesel Pump)

1

13100

13100

... More
150 mm nominal dia for (2Elect+1Diesel Pump)

3

30000

10000

... More
80 mm nominal dia for two nos J Pump

2

11200

5600

... More
Supplying, Installing, testing and commissioning ISI Mark CI butterfly valves( PN 16) slim seal standared lever operated type with required flanges, nuts, bolts etc. complete.Make:Kartar/AIP/Veeson/CRI/Intervalve

1

-

-

... More
250mm nominal dia(Tank Connection)

2

27000

13500

... More
150mm nominal dia(2 Elect+1 Diesel Pump)

6

53820

8970

... More
80mm nominal dia(For Jockey Pump)

4

17640

4410

... More
Supplying, Installing, testing and commissioning ISI Mark Rubber Bellow with required flanges, nuts, bolts etc. complete.Make:Kartar

1

-

-

... More
150mm nominal dia(2 Elect+1 Diesel Pump)

6

49800

8300

... More
80mm nominal dia(For Jockey Pump)

4

22400

5600

... More
Supplying, installing and commissioning C.I.flanged "Y Srainer" with suitable flanges, nuts, bolts, gaskets etc. complete.

1

-

-

... More
150mm dia.

3

37500

12500

... More
80mm dia.

2

17600

8800

... More
Supply and installation of Pressure switches of suitable range for pumpsets with Fittings like Ball Valve unions / colors / reducers etc.Make:Indfoss/Danfoss

5

29750

5950

... More
Supply and installation of Pressure gauges of suitable range for pumpsets with Fittings like Ball Valve,unions / colors / reducers etc.Make:H.Guru,Pricol

5

8500

1700

... More
Supplying and installation of Fire pressure vessel of 300mm dia and 2.0m high fabricated from 6-8 mm thick M.S. plate suitable for 10kg/sqcm. working pressure with accessories, painted with two coats of Postal red enamel outside over a coat of primer for automatic operation of pump.

1

43500

43500

... More
B. EXTERNAL HYDRANT AND TERRACE PIPING:

1

-

-

... More
Supplying, installing, testing and commissioning of M.S Pipes confirming to IS 1239 Pt - I Heavy grade with painting, suitable type of supports ( Shall be fabricated by M.S. Channel / Angle / Flat for above 50 mm dia), anchor fasteners, bolts nuts, clamps, "U" bolte, malleable specials such as Reducers,Tees, elbows, flanges. Including cutting, Welding, fixing in / on walls, ceiling by using suitable supports etc, as per drawings. The quoted rate shall also include for chasing / chipping walls, making bore holes in walls / floor and making them good with filler material and finished in cement morter etc. complete.Make:Tata/Jindal

1

-

-

... More
150 mm dia (Basement Ring Main)

200

466400

2332

... More
100 mm dia (Terrace Ring Main)

50

94200

1884

... More
80 mm dia (Hydrant Post)

42

57540

1370

... More
Supplying, Installing, testing and commissioning ISI Mark CI butterfly valves( PN 16) slim seal standared lever operated type with required flanges, nuts, bolts etc. complete.Make:Kartar/AIP/Veeson/CRI/Intervalve

1

-

-

... More
150mm nominal dia(For Ring Main and 4 Way )

4

35000

8750

... More
100mm nominal dia(For Terrace Piping))

6

41400

6900

... More
Supplying, installing and commissioning C.I.flanged "Y Srainer" with suitable flanges, nuts, bolts, gaskets etc. complete.

1

-

-

... More
100mm dia.(For Terrace Tank)

1

10580

10580

... More
Single headed hydrant valve as per IS 5290, made of S.S with 63 mm dia instantaneous outletof 80 mm dia fanged inelt ,Blank caps , chain and hand wheels etc complete.Make-Ronak/Kartar

6

34680

5780

... More
2 lengths of 15 M long, 63mm dia RRL hose with instataneuos couplings and Hoses shall be stored in side the hose cabinet.Make-Ronak/Kartar

12

54600

4550

... More
1 no. S.S short branch pipe with nozzle.Make-Ronak/Kartar

6

12990

2165

... More
M.S. Hose Cabinet fabricated out of M.S. sheet of 16 swg. with glass fronted ( 4mm thick glass with rubber beeding) and size of the Cabinet shall be 600 mm (L)x450mm(H)x250mm(Width).Quoted rate shall be includes Hinges, all fasteners etc, and Door shall be powder coated of approved colour both inside and out side.Make-Ronak/Kartar

6

24000

4000

... More
Supplying, installing and commissioning of fire brigade inlet inlet connection of 4 way with 4 nos. 63 mm dia. built - in Gun metal Non- return valves instantaneous coupling type arranged on 150 mm dia. Pipe manifold and connected to wet riser main .Make-Ronak/Kartar

1

10300

10300

... More
C. INTERNAL HYDRANT AND TERRACE:

1

-

-

... More
Supplying, installing, testing and commissioning of M.S Pipes confirming to IS 1239 Pt - I Medium grade with painting, suitable type of supports ( Shall be fabricated by M.S. Channel / Angle / Flat for above 50 mm dia), anchor fasteners, bolts nuts, clamps, "U" bolte, malleable specials such as Reducers,Tees, elbows, flanges. Including cutting, Welding, fixing in / on walls, ceiling by using suitable supports etc, as per drawings. The quoted rate shall also include for chasing / chipping walls, making bore holes in walls / floor and making them good with filler material and finished in cement morter etc. complete.Make:Tata/Jindal

1

-

-

... More
150mm nominal dia

6

13992

2332

... More
100mm nominal dia

124

233616

1884

... More
80mm nominal dia

9

12330

1370

... More
Supplying, Installing, testing and commissioning ISI Mark CI butterfly valves( PN 16) slim seal standared lever operated type with required flanges, nuts, bolts etc. complete.Make:Kartar/AIP/Veeson/CRI/Intervalve

1

-

-

... More
100mm nominal dia (For Riser and 2 way FSI)

4

27600

6900

... More
Single headed hydrant valve as per IS 5290, made of S.S with 63 mm dia instantaneous outletof 80 mm dia fanged inelt ,Blank caps , chain and hand wheels etc complete..Make-Eversafe/OMEX/BRG/CRC

30

173400

5780

... More
2 lengths of 15 M long, 63mm dia RRL hose with instataneuos couplings and Hoses shall be stored in side the hose cabinet..Make-Eversafe/OMEX/BRG/CRC

60

273000

4550

... More
1 no. S.S short branch pipe with nozzle..Make-Eversafe/OMEX/BRG/CRC

30

64950

2165

... More
Hose reel drum of swinging type with 19mm dia Rubber braided hose of 30M. length with Gate valve ( upstream) and Shut off nozzle, complete.Make:Eversafe,Gteck,Minimax

30

198000

6600

... More
M.S. Hose Cabinet fabricated out of M.S. sheet of 16 swg. with glass fronted ( 4mm thick glass with rubber beeding) and size of the Cabinet shall be 600 mm (L)x450mm(H)x250mm(Width).Quoted rate shall be includes Hinges, all fasteners etc, and Door shall be powder coated of approved colour both inside and out side.Make-Ronak/Kartar

6

64200

10700

... More
Supplying and installation of Fire Air vessel of 150mm dia and 1m high fabricated from 6-8 mm thick M.S. plate suitable for 10kg/sqcm. working pressure with accessories, painted with two coats of Postal red enamel outside over a coat of primer

2

30600

15300

... More
Supplying, installing and commissioning of fire brigade inlet inlet connection of 2 way with 2nos. 63 mm dia. built - in Gun metal Non- return valves instantaneous coupling type arranged on 150 mm dia. Pipe manifold and connected to wet riser main . Qouted rate shall be included with C.I. Butterfly valve, complete.Make:Eversafe,Gteck,Minimax

2

15300

7650

... More
Supplying, installing, testing and commissioning of Gun metal /Brass Forged chrome finished Ball valves with fittings of screwed end type.Make:Zoloto/Leader

1

-

-

... More
25mm dia.(Forhose reel)

30

35400

1180

... More
D. FIRE EXTINGUISHERS:

1

-

-

... More
Supplying, installing and commissioning Portable Fire extinguishers of following type & capacity.Make-Omex,Kanex,Safex

1

-

-

... More
Providing and fixing Co2 type fire extinguisher as per IS 2878 with discharge time of 10 sec to 18 sec and gas storage pressure of 85 kgf/sq cm with internal charge. i) Capacity 4.5kg (Wall Mounted)

54

334800

6200

... More
ABC chemical powder type fire extinguisher of 6 Kgs. Capacity, with initial filling in brand new cylinder with powder coated finish, fitted with Gun metal union, high pressure CO2 gas cartridge, discharge hose, wall mounting bracket etc. complete, confirming to IS:15683

75

191250

2550

... More
Providing and fixing 9 Litres capacity fire extinguisher water type Gas Pressure conforming to IS: 940 marking, fixed to wall.

15

36750

2450

... More
Providing and fixing Mechanical Foam of 9ltr Capacity

8

20400

2550

... More
Providing and fixing Clean of Agent of 4Kg Capacity

12

253200

21100

... More
Providing and fixing of clean agent Modular Type Extinguisher of 5 Kg Capacity

60

1152000

19200

... More
Providing and fixing of ABC type fire ball of 1.0kg of capacity .

250

775000

3100

... More
Fire Bucket

2

3800

1900

... More
E. AUTOMATIC FIRE ALARM SYSTEM:

1

-

-

... More
Analog Addressable Fire Alarm Control panel with battery back up for 8 hours normal operation and 15 minutes alarm operation. The control panel, battery charger etc, shall be UL / EN listed.The panel shall be 4 loops capacity and expandable to 6 loops. The panel shall consisting with 80 character LCD display and RS 485 for networking. Make-Firelite/GST/Morley IAS/EST

1

224259

224259.7

... More
Analogue Addressable Multi Sensor Smoke detector with programmable for timed automatic sensitivity selection with base, Junction box and other accessories as required and Cetectors shall be UL listed,Make-Firelite/GST/Morley IAS/EST

537

1460640

2720

... More
Addressable Single action Manual pull station having an integrally mounted addressabla module that monitors and reports contact status.Make-Firelite/GST/Morley IAS/EST

30

93838

3127.95

... More
Addressable Horn / Strobe wall mounted type rated at 82 dBA @ 3m for Audible annunciation and 75cd flashintg at 1 Hz for visual indication.Make-GST/EST/Morley IAS

30

97012

3233.75

... More
Analogue Addressable Fault isolator module capable of monitoring shorted loop circuit and automatically restore communications when shorted conditions are corrected,Make-Firelite/GST/Morley IAS/EST

35

84120

2403.45

... More
Supplying, installing, testing and commissioning of 2 runs of 1.5 sq. mm, PVC insulated copper wires confirming to IS standards and specifications.(For Alarm and water flow Detector)Make-Finolex,Polycab,R.R Kable

10000

970000

97

... More
Supplying, laying, testing and commissioning of Response Indicator for Above Ceiling Detector-Make-Firelite/GST/Morley IAS/EST

240

37200

155

... More
Supplying, laying, testing and commissioning of Addressable Beam Detector-Firelite/GST/Morley IAS/EST

2

86000

43000

... More
SIGNAGES: Providing and installing in position the following type of sign boards made out of 3mm thick "Opaque" PVC foam board with computer cut, PVC non-reflective self adhesive vinyle painted foam board, complete with mirror fasteners.

1

-

-

... More
Floor indentification signage ( ie, GROUND FLOOR …etc.) at each stair enclosure on every floor, indicating the floor number in words, lettering size shall be 7.5 cm with contrasting colour from back ground.Size shall be 15cm x 60cm.

20

10000

500

... More
Providing and fixing the signages "Fire Exit, Fire Exit Arrow Down,Fire Exit Arrow Left,Fire Exit Arrow Right"of 1.5cm height letters in white with green back ground.The size of the board shall be 25cm x 15 cm and shall be fixed at the height of 2 mts

80

40000

500

... More
Illumination Glow light for Exit Indication with Battery Back-up,Make-Agni Device/Prolite/Any ISI Make

100

430000

4300

... More
F. AUTOMATIC SPRINKLER SYSTEM:

1

-

-

... More
Supplying, installing, testing and commissioning of M.S. Pipes confirming to IS 1239 Pt - I Heavy grade with painting, suitable type of supports ( for above 50 mm dia, shall be fabricated by M.S. Channel / Angle / Falts etc), anchor fasteners, bolts nuts , clamps, "U" bolte, malleable specials such as Reducers,Tees, elbows, flanges. Including cutting, Welding, fixing in / on walls, ceiling by using suitable supports etc, as per drawings. The quoted rate shall also include for chasing / chipping walls, making bore holes in walls / floor and making them good with filler material and finished in cement morter etc. complete.Make:Tata,Jindal

1

-

-

... More
150mm nominal dia

48

111936

2332

... More
100mm nominal dia

168

316512

1884

... More
80mm nominal dia

246

337020

1370

... More
65mm nominal dia

258

297216

1152

... More
50mm nominal dia

264

253440

960

... More
40mm nominal dia

180

126360

702

... More
32mm nominal dia

300

172200

574

... More
25mm nominal dia

1560

748800

480

... More
Supplying, Installing, testing and commissioning CI butterfly valves ( PN 16) as per BS 5155 slim seal standared lever operated type with required flanges, nuts, bolts etc. complete.Make:Make:Kartar/AIP/Veeson/CRI/Intervalve

1

-

-

... More
150mm nominal dia

9

78750

8750

... More
100mm nominal dia

5

34500

6900

... More
Supplying, installing, testing and commissioning of hydraulically operated Sprinkler control valve, with water motor gong bell and trims as required, pressure gauges, drain valves, ball valves, check valves, strainers etc. complete. Alarm valve shall be UL Listed / FM approved.Make:HD,VIKING

1

-

-

... More
150mm dia

1

65600

65600

... More
Supplying, installing, testing and commissioning conventional Sprinkler quartzoid bulb type with 15mm screwed end connection of 68 deg. C. temperature rating,K 80 and orifice shall not be less than 6mm.Sprinklers shall be UL Listed / FM approved with Chrome finished.Make:Viking/HD/Minimax

1

-

-

... More
Pendent Standard sprinkler

631

246090

390

... More
Side Wall Upright sprinkler

210

81900

390

... More
Side Wall Sprinkler

50

20500

410

... More
Supplying, installing, testing and commissioning of Gun metal /Brass Forged chrome finished Ball valves with fittings of screwed end type.Make:Zoloto/Leader

1

-

-

... More
50mm dia.(Drainage )

15

49800

3320

... More
Supplying, installing, testing and commissioning of Stainless steel corrugated flexible pipe(hose) for dropping sprinklers below false ceiling, pipe shall be 16 bar pressure rating and 1500 mm long 25 mm dia with union / reducer collar, clamps etc. as required.Make:Easy flex/Omex/Uniflex

210

357000

1700

... More
Supplying, installing, testing and commissioning of Flow meter/waterflow DetectorMake:System sensor

1

-

-

... More
100mm dia

12

104400

8700

... More
Structural Item for Sprinler Piping Support(Hager,Tie Rod,Anchor Fastner etc)

1

100000

100000

... More
Supplying, installing, testing and commissioning solid state Amplifier of 300 W RMS out put in rack, including necessory control wires, jocks etc. complete.Make-Bosch/Ahuja/Cherytech

1

44500

44500

... More
Supplying, installing, testing and commissioning 6W wall mounted type speakers with talk back facility, in CRCA sheet fabricated housing, complete.Make-Bosch/Ahuja/Cherytech

30

60000

2000

... More
Supplying, installing, testing and commissioning of 2 runs of Speaker Wire

5000

465000

93

... More
BOUNDARY WALL:

1

-

-

... More
Earth work in excavation IN ALL KINDS OF SOILS by manual means overareas (exceeding 30 cm in depth, 1.5 m in width as well as 10sqm on plan) inculding disposal of excavated earth up to 50 m and lift upto 1.5m with all lead and lift including shoring, shuttering & dewatering (if required) with cost of all Labour, Labour cess ,Hire & Running charges of the water pumps, Sundries, T & P required for the work complete as directed by the Engineer- in- charge.

444.4

65771

148

... More
Earth work in hard soil or gravelly soil within 50m. Initial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per the direction of the Engineer-in-charge.+1.5m extra lift.

213.07

33809

158.68

... More
Supplying & Filling foundation trenches , plinth & ditches with clean course river sand well watered and rammed in layers not exceeding 23 c.m. in depth with all lead and lift including cost, conveyance, loading, unloading, stacking,royalties and all taxes of sand,cost & conveyance of water, cost of all Labour,labour cess,T&P required for the work etc. complete in all respect as directed by the Engineer- in -charge.

331.2

106215

320.7

... More
Back filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5m.

122.9

12130

98.7

... More
Providing and laying Plain cement concrete of proportion(1:3:6) in foundation and floors(i.e. below the base course of the flooring) using cement, 40mm. Size crusher broken H.G.Metal and screened and washed sharp river sand for mortar of approved quality and from approved quarry including hoisting, lowering and laying concrete to the required level, ramming, watering and curing etc. complete to required levels, laid in layers not exceeding 15cm thick in each layer including cost, conveyance, loading, unloading,royalities and taxes of all materials, cost of all labour,T&P required for the work including shoring,shuttering and dewatering(if required)including hire and running charges of water pump required for the work etc. complete in all respect as directed by the Engineer-in-charge.

29.6

117819

3980.4

... More
Providing and laying in position ready mixed M-25 grade concrete having compressive strength at 28 days test not less than 250 kg/ sq.cm for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying , including the cost of centering, shuttering finishing and excluding reinforcement including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, and hoisting, lowering, laying and compacting concrete, watering and curing and finishing the exposed surfaces smooth with cost, conveyance, royalties, taxes of all materials with all labour,Labour cess and T&P required for the work improve workability without impairing strength and durability as per direction of the Engineer - in - charge.

1

-

-

... More
RCC up to Plinth level: Footing

111.3

544546

4892.6

... More
RCC Columns footing top to F.G.L

4.8

43594

9082.2

... More
R.C.C in Retaining wall

57.7

372193

6450.5

... More
R.C.C in Plinth beam

6.7

34806

5195

... More
RCC above FGL level: RCC in col.

15.9

144406

9082.2

... More
R.C.C in Retaining wall

57.7

372193

6450.5

... More
R.C.C tie Band

10.7

97179

9082.2

... More
Cutting,straightening coiled or bent up HYSD/TMT Reinfocement Bars welding or jointing if necessary ,bending, binding,tying the grills as required for R.C.C. works,providing Fan Hooks where necessary and hoising,lowering and placing the same tin proper position according to the approved eesigns and drawings in all floors including cost, conveyance, loading, unloading and taxes or HYSD/TMT Reinforcement Bars and Binding wieres of 18 to 20 gauge required for the work cost of all labour,T&P and scaffolding complete in all respect as directed by the Engineer-in-charge(Payment will be made according to the actual/proper weight of HYSD/TMT Reinforcement Bars and Binding wires consumed in the particular work only)

264.8

1696838

6408

... More
Fly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12 c.m x 8 c.m in Foundation & Plinth having crushing strength not less than 75 kg per square c.m. with cement and screened & washed sharp sand for mortar after immersing the bricks for 6 (Six) hours in water before use in works with all necessary projections, splays cutting, circular moulding, corbelling, chamfering, watering and curing etc. including cost, coveyance, stacking, loading, unloading, royalties , all taxes ,cost of all labour,Labour cess ,scaffolding, sundries and T&P required for the works etc. complete in all respect as directed by the Engineer-in-charge.

118.1

416420

3526

... More
Providing 12mm. Thick cement plaster in cement mortar or mix(1:6) in all floors at all height with cement & screened and washed sharp river sand for mortar and finished smooth to the rough surface of the brick masonary walls after racking out the joints (alongwith providing grooves wherever necessary) including watering and curing,rounding of corners etc. complete with cost, conveyance, loading, unloading, royalities and taxes of all materials,cost of all labour,T&P, and scaffolding required for the work etc. as directed by the Engineer-in-charge.

1155.8

115811

100.2

... More
Providing 6 mm thick cement plaster in cement mortar of mix (1:4) at all height using screened & washed sharp river sand for mortar with approved quality of cement to the ceiling of the Roof Slab, Staircase, Beams, Columns,Landings, Railings,Chajja ,Fins ,Walls ,Jally and Shelves etc. including roughening, scraping, chiseling, cleaning, closed deep chipping with slurry treatment and finished smooth to all R.C.C. Surface including cost, conveyance, loading, unloading, royalties ,stacking and all taxes , cost of all Labour,Labour cess ,Sundries, T&P, Scaffolding, Watering, Curing etc. complete in all respect as directed by the Engineer- in- charge.

219.24

23370

106.6

... More
Priming one coat with af approved quality of water bound cement primer of APPROVED make including cost, conveyance and taxes of all materials & cost ,conveyance taxes of all labour with T & P required etc complete in all respect as per the direction of the Eng.-in-charge

1375

59675

43.4

... More
Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm.

1375

184250

134

... More
Supplying, fitting and fixing of M.S grills, grill gates with top and bottom rails, steel windows, steel doors, steel frames for doors and windows ( as per I.S. specification and as per approved drawings ) in proper position in all floors and at all height including making holes to brick walls/ R.C.C structure/wood work etc. and making good to the damaged walls/ structures with cement concrete (1:2:4) with black hard crusher broken granite stone chips of 12mm to 20mm size ( 20mm size not to exceeds 25% ) including watering and curing including cost, conveyance, loading, unloading, stacking, royalties and taxes of all materials, cost of all Labour, Labour cess ,Sundries, T&P required for the work etc.complete as per the direction of Engineer in charge ( W.I. / M.S. windows grills, grill gates, collapsible gates with top and bottom rails, steel windows, steel doors, steel frames for doors and windows, staircase and parapet railings square bar along with required nos. of nails and screws and other required materials of approved quality and approved size shall be supplied by the contractor at his own cost.)

6854.4

401667

58.6

... More
Painting with synthetic enamel paint of approved colour, shade and brand on New steel work in two or more coats as required to give an even shade including an under coat of suitable primer of approved brand and manufacturer including cost of all materials with taxes and transportation, loading, unloading, scaffolding, all labour, Labour cess, sundries, T&P, etc. complete as per the direction of the Engineer-in-charge including filling gaps with putties, scrapping, sand papering and cleaning the surface to make free from rusts, dusts and oily substances before applying primer etc. complete.

114.2

15382

134.7

... More
CC Road and Parking:

1

-

-

... More
Loosening, Leveling & Compacting original ground supporting embankment to faciliate placement of first layer of embankment, scarified to a depth 150mm, mixed with water at OMC and then compacted by rolling so as to achive minimum dry dencity as given in Table 300-2 for embankment construction.

989.1

20177

20.4

... More
Construction of granular sub-base by providing Close graded Granular subbase Grading-III material as per table 400-1, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density complete as per Clause 401 of MOSRT&H Specifications for Road & Bridge works

247.28

340034

1375.1

... More
Supplying & Filling foundation trenches , plinth & ditches with clean course river sand well watered and rammed in layers not exceeding 23 c.m. in depth with all lead and lift including cost, conveyance, loading, unloading, stacking,royalties and all taxes of sand,cost & conveyance of water, cost of all Labour,labour cess,T&P required for the work etc. complete in all respect as directed by the Engineer- in -charge.

164.85

52867

320.7

... More
Providing and laying Plain cement concrete of proportion(1:3:6) in foundation and floors(i.e. below the base course of the flooring) using cement, 40mm. Size crusher broken H.G.Metal and screened and washed sharp river sand for mortar of approved quality and from approved quarry inclduign hoisting, lowering and laying concrete to the required level, ramming,watering and curing etc. completek to required levels, laid in layers not exceeding 15cm thick in each layer including cost, conveyance, loading, unloading,royalities and taxes of all materials, cost of all labour,T&P required for the work including shoring,shuttering anddewatering(if required)including hire and running charges of water pump required for the work etc. complete in all respect as directed by the Engineer-in-charge.

256.14

1019539

3980.4

... More
Providing and laying in position ready mixed M-25 grade concrete having compressive strength at 28 days test not less than 250 kg/ sq.cm for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying , including the cost of centering, shuttering finishing and excluding reinforcement including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, and hoisting, lowering, laying and compacting concrete, watering and curing and finishing the exposed surfaces smooth with cost, conveyance, royalties, taxes of all materials with all labour,Labour cess and T&P required for the work improve workability without impairing strength and durability as per direction of the Engineer - in - charge.

384.21

1879785

4892.6

... More
Back filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5m.

236.7

23362

98.7

... More
ELECTRICAL PANEL ROOM:

1

-

-

... More
Earth work in excavation IN ALL KINDS OF SOILS by manual means overareas (exceeding 30 cm in depth, 1.5 m in width as well as 10sqm on plan) inculding disposal of excavated earth up to 50 m and lift upto 1.5m with all lead and lift including shoring, shuttering & dewatering (if required) with cost of all Labour, Labour cess ,Hire & Running charges of the water pumps, Sundries, T & P required for the work complete as directed by the Engineer- in- charge.

58.32

8631

148

... More
Supplying & Filling foundation trenches , plinth & ditches with clean course river sand well watered and rammed in layers not exceeding 23 c.m. in depth with all lead and lift including cost, conveyance, loading, unloading, stacking,royalties and all taxes of sand,cost & conveyance of water, cost of all Labour,labour cess,T&P required for the work etc. complete in all respect as directed by the Engineer- in -charge.

64.98

20839

320.7

... More
Providing and laying Plain cement concrete of proportion(1:3:6) in foundation and floors(i.e. below the base course of the flooring) using cement, 40mm. Size crusher broken H.G.Metal and screened and washed sharp river sand for mortar of approved quality and from approved quarry inclduign hoisting, lowering and laying concrete to the required level, ramming,watering and curing etc. completek to required levels, laid in layers not exceeding 15cm thick in each layer including cost, conveyance, loading, unloading,royalities and taxes of all materials, cost of all labour,T&P required for the work including shoring,shuttering anddewatering(if required)including hire and running charges of water pump required for the work etc. complete in all respect as directed by the Engineer-in-charge.

22.57

89837

3980.4

... More
Back filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5m.

11.03

1088

98.7

... More
Disposal of surplus excavted materials by mechanical means from the work side etc. complete. upto 5km. Lead

47.29

7148

151.17

... More
Providing and laying in position ready mixed M-25 grade concrete having compressive strength at 28 days test not less than 250 kg/ sq.cm for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying , including the cost of centering, shuttering finishing and excluding reinforcement including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, and hoisting, lowering, laying and compacting concrete, watering and curing and finishing the exposed surfaces smooth with cost, conveyance, royalties, taxes of all materials with all labour,Labour cess and T&P required for the work improve workability without impairing strength and durability as per direction of the Engineer - in - charge.

1

-

-

... More
All works upto plinth level

10.8

53740

4975.99

... More
Column from footing top to NGL

1.03

9354

9082.2

... More
Column from NGL to PL

0.32

2906

9082.2

... More
RCC in plinth beam

3.43

17818

5195

... More
RCC in column from PL to Ground floor roof lvl

4.86

44139

9082.2

... More
RCC in Roof beam

3.14

28518

9082.2

... More
RCC in roof slab

17.58

143066

8138

... More
Lintel

1.37

10637

7764.6

0.83

6444

7764.6

... More
Chajja

17.69

12043

680.8

... More
Cutting,straightening coiled or bent up HYSD/TMT Reinfocement Bars welding or jointing if necessary ,bending, binding,tying the grills as required for R.C.C. works,providing Fan Hooks where necessary and hoising,lowering and placing the same tin proper position according to the approved eesigns and drawings in all floors including cost, conveyance, loading, unloading and taxes or HYSD/TMT Reinforcement Bars and Binding wieres of 18 to 20 gauge required for the work cost of all labour,T&P and scaffolding complete in all respect as directed by the Engineer-in-charge(Payment will be made according to the actual/proper weight of HYSD/TMT Reinforcement Bars and Binding wires consumed in the particular work only)

41.42

265419

6408

... More
Fly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12 c.m x 8 c.m in Foundation & Plinth having crushing strength not less than 75 kg per square c.m. with cement and screened & washed sharp sand for mortar after immersing the bricks for 6 (Six) hours in water before use in works with all necessary projections, splays cutting, circular moulding, corbelling, chamfering, watering and curing etc. including cost, coveyance, stacking, loading, unloading, royalties , all taxes ,cost of all labour,Labour cess ,scaffolding, sundries and T&P required for the works etc. complete in all respect as directed by the Engineer-in-charge.

2.74

9576

3492.6

... More
Aerated Autoclaved Concrete blocks of size 625mmX200mmX200mm having compressive strength more than 4N/ sqmm confirming to IS:2185-Part-3-1984 & IS:6441-1972 of Lean/Aerolite or equivalent products in cement mortar of mix (1:6) using cement of approved quality, screened & washed sand for use in super structure including splays cutting, circular moulding , corbrlling, champering & similar such type of works, watering & curing etc. including cost, conveyance, royalty, loading, unloading of all materials, cost of labour, scaffolding, sundries, T & P required for the works etc. complete in all respect as directed by the Engineer-in-charge.

30.67

125057

4077.53

... More
Providing 12mm. thick cement plaster in cement mortar or mix(1:6) in all floors at all height with cement & screened and washed sharp river sand for mortar and finished smooth to the rough surface of the brick masonary walls after racking out the joints (alongwith providing grooves wherever necessary) including watering and curing,rounding of corners etc. complete with cost, conveyance, loading, unloading, royalities and taxes of all materials,cost of all labour,T&P, and scaffolding required for the work etc. as directed by the Engineer-in-charge.(Outer side)

268.14

26867

100.2

... More
Providing 12mm. Thick cement plaster in cement mortar or mix(1:6) in all floors at all height with cement & screened and washed sharp river sand for mortar and finished smooth to the rough surface of the brick masonary walls after racking out the joints (alongwith providing grooves wherever necessary) including watering and curing,rounding of corners etc. complete with cost, conveyance, loading, unloading, royalities and taxes of all materials,cost of all labour,T&P, and scaffolding required for the work etc. as directed by the Engineer-in-charge. (Inside)

156.54

15685

100.2

... More
Providing 6 mm thick cement plaster in cement mortar of mix (1:4) at all height using screened & washed sharp river sand for mortar with approved quality of cement to the ceiling of the Roof Slab, Staircase, Beams, Columns,Landings, Railings,Chajja ,Fins ,Walls ,Jally and Shelves etc. including roughening, scraping, chiseling, cleaning, closed deep chipping with slurry treatment and finished smooth to all R.C.C. Surface including cost, conveyance, loading, unloading, royalties ,stacking and all taxes , cost of all Labour,Labour cess ,Sundries, T&P, Scaffolding, Watering, Curing etc. complete in all respect as directed by the Engineer- in- charge

166.18

17714

106.6

... More
Priming one coat with af approved quality of water bound cement primer of APPROVED make including cost, conveyance and taxes of all materials & cost ,conveyance taxes of all labour with T & P required etc complete in all respect as per the direction of the Eng.-in-charge

590.86

25643

43.4

... More
Wall painting two coats with plastic emulsion of approved quality of premium brand such as Asian/ Berger/ ICI paints or equivalent of approved quality & colour at all heights to the interior surface of the wall to make an even finished surface including sand papering, applying putty wherever necessary including cost, conveyance, loading, unloading, stacking, all taxes , cost of all Labour , Labour cess,scaffoldings, staging, sundries,T&P etc. required for the work complete as directed by the Engineer-in-charge.

322.72

19911

61.7

... More
Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm.

268.14

35930

134

... More
25mm thick AS flooring with cement concrete in proportion (1:2:4) using black hard crusher broken granite chips laid in two layers , the bottom layer being 20mm thick and the top layer 6mm thick with cement punning laid over 100mm thick metal concrete including watering,curing etc complete including cost, conveyance royalties and taxes of all materials and cost of all labour with T&P required for the work etc complete in all respects as per the direction of the Engineer in charge.

130.79

30644

234.3

... More
Providing & fixing flexible PVC sheet with static dissipative properties in 2.0 mm,thickness single layer homogeneous in the size of 2m*23m with carbon backing,classification 34/43,meeting with EN 1081,with the value of r 10⁸ Ohms.results from independent testing demonstrate that it doesnt favour growth of bacteria.The static dissipative properties must be present through prioduct thickness.Homogeneous vinyl flooring with total weight 3000 g/m²,PUR reinforced,Abrasion group:4.0 mm³,residual idention 0.10 mm,castrol chair test qualified,dimensional stability0.40%.as per EN 434,static electrical charge EN 1081 good resistance to slip,scratch,chemical n& fire.No damage from furniture leg,slip resistance,R90.3,ESD is 100% recyclable,equivalent to Tarkett Primo SD.

130.79

230292

1760.78

... More
Providing & fixing PVC sheet wall covering in 1.30 mm thickness in the size 2m* 30m wit PU shield,with the testing results of inhibits the growth of bacteria.Homogeneous vinyl wall covering with total weight 2100 g/m2,dimensional stability 0.40%,wet room test qualified,good resistance to chemical & fire,available in various colour shade,equivalent to Tarkett Wallgard.

115.92

129243

1114.94

... More
Supplying, fitting and fixing of M.S grills, grill gates with top and bottom rails, steel windows, steel doors, steel frames for doors and windows ( as per I.S. specification and as per approved drawings ) in proper position in all floors and at all height including making holes to brick walls/ R.C.C structure/wood work etc. and making good to the damaged walls/ structures with cement concrete (1:2:4) with black hard crusher broken granite stone chips of 12mm to 20mm size ( 20mm size not to exceeds 25% ) including watering and curing including cost, conveyance, loading, unloading, stacking, royalties and taxes of all materials, cost of all Labour, Labour cess ,Sundries, T&P required for the work etc.complete as per the direction of Engineer in charge ( W.I. / M.S. windows grills, grill gates, collapsible gates with top and bottom rails, steel windows, steel doors, steel frames for doors and windows, staircase and parapet railings square bar along with required nos. of nails and screws and other required materials of approved quality and approved size shall be supplied by the contractor at his own cost.)

378

22150

58.6

... More
Painting two coats with synthetic enamel paint of approved colour, shade and brand on New wood/steel work in as required to give an even shade including an under coat of suitable primer of approved brand and manufacturer including cost of all materials with taxes and transportation, loading, unloading, scaffolding, all labour, Labour cess, sundries, T&P, etc. including filling gaps with putties, scrapping, sand papering and cleaning the surface to make free from rusts, dusts and oily substances before applying primer etc. complete.as per the direction of the Engineer-in-charge

28.8

3879

134.7

... More
Providing and fixing factory made uPVC white colour fixed glazed windows/ ventilators comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), , uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area upto 0.75 sqm.)

12.6

65109

5167.42

... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With Frosted glass panes of 4 mm thickness

12.6

10814

858.3

... More
2.5 cm thick grading concrete (1:2:2) on roof slab with 6mm size HG chips including all cost, conveyance, royalty & taxes etc.comp.to work site for new work as per the specification approved by the department & direction of E.I.C

130.79

29924

228.8

... More
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).

124.69

38778

311

... More
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover

10

21800

2180.01

... More
Providing and fixing ball bearing for rolling shutters as per drawing including cost of conveyance etc. as per the direction of the engineer incharge.

6

2275

379.29

... More
Extra for providing mechanical device chain and crank operation for operating rolling shutters. Exceeding 16.80 sqm in area

9.4

6806

724.07

... More
Providing fitting and fixing up partition walling OEL aluminum anodized section No.9210 and 9207 as single groove and double groove respectively as horizontal and vertical member and OEL section 4660 as Tapered clip for fixing up 12mm thick pre laminated board (Nova pan Make) and jointing angle No. 1855 with 6mm thk plain glass etc.

70.2

196412

2798.1

... More
Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontal side & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mm thick GI sheet ( Zinc coating not less than 120gm/m²) suitable for mounting 120 min Fire Rated Glazed Door Shutters. The frame shall be filled with Mineral wool Insulation having density min 96Kg/m³ . The frame will have a provision of G.I. Anchor fastners 14 nos ( 5 each on vertical style & 4 on horizontal style of size M10 x 80 ) suitable for fixing in the opening along with Factory made Template for SS Ball Bearing Hinges of Size 100x89x3mm for fixing of fire rated glazed shutter. The frame shall be finished with a approved fire resistant primer or Powder coating of not less than 30 micron in desired shade as per the directions of Engineer - in- charge . (Cost of SS ball bearing hinges is excluded).

14.4

17781

1234.85

... More
Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 min Fire Rating confirming to IS:3614 (Part II) or EN1634- 1:1999, tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mm wide and bottom rail of 110 mm x 60 mm made out of 1.6mm thick G.I. sheet (zinc coating not less than 120gm/m²) duly filled mineral wool insulation having density min 96 kg/m³ and fixing with necessary stainless steel ball bearing hinges of size 100x89x3mm of approved make, including applying a coat of approved fire resistant primer or powder coating not less than 30 micron etc all complete as per direction of Engineer-in-charge (panelling to be paid for seperately).

5.76

39394

6839.34

... More
Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions etc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c , including applying a coat of approved fire resistant primer/powder coating of not less than 30 micron on G.I. beading, & special ceramic tape of 5 x 20 mm size etc complete in all respect as per direction of Engineer-in-charge. The glass shall be clear, toughened, interlayered, non-wired fire resistant having 11 mm thickness of approved brand with 120 minutes of fire resistance both integrity & radiation control (EW120) and minimum 15 min of insulation (EI15) and having a sound reduction of 37dB and LT of 86%. Glass shall be compliant to class 2(B)2 category of Impact Resistance as per EN 12600. The glass should be manufactured in UL & TUV audited Facility and including UL-EU Certification.The maximum glazing size cannot be more than 1100 mm x 2200 mm (w x h) or 2.42 sq mts in total area. The test report for the complete system (Glazed Door or Partition) will be considered valid only if it contains the stamp and signature of the authorized signatory from the glass manufacturer.

5.76

196179

34058.91

... More
LANDSCAPING:

1

-

-

... More
Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure).

899.96

27097

30.11

... More
Supplying and stacking sludge at site including royalty and carriage upto 5 k.m. lead complete (sludge measured in stacks will be reduced by 8% for payment).

299.99

71367

237.9

... More
Supplying and stacking at site dump manure from approved source, including carriage upto 5 k.m. lead complete (manure measured in stacks will be reduced by 8% for payment) : Screened through sieve of I.S. designation 20 mm

149.99

24115

160.78

... More
Rough dressing the trenched ground including breaking clodswith cost of all Labour, Labour cess ,Hire & Running charges of the water pumps, Sundries, T & P required for the work complete as directed by the Engineer- in- charge.

2999.85

1799

0.6

... More
Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetationwith cost of all Labour, Labour cess ,Hire & Running charges of the water pumps, Sundries, T & P required for the work complete as directed by the Engineer- in- charge.

2999.85

5609

1.87

... More
Fine dressing of the ground with cost of all Labour, Labour cess ,Hire & Running charges of the water pumps, Sundries, T & P required for the work complete as directed by the Engineer- in- charge.

2999.85

4379

1.46

... More
Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge.

899.96

12365

13.74

... More
Grassing with selection No. 1 grass including watering and maintenance of the lawn for 60 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the grass and good earth shall be paid for separately). In rows 5 cm apart in both directions

2999.85

19919

6.64

... More
Providing & laying Selection no. 1 grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same, with sprinkler and maintenance for 30 days or more till the grass established properly as per direction of officer in charge.

2999.85

218809

72.94

... More
PAVED PATHWAY:

1

-

-

... More
Providing & laying of 80mm thick factory made cement concrete interlocking paver block of M-30 grade & approved make, varity, colour & size made by Block making machine with strong vibratory compaction of approved design & shape laid in required colour & pattern over 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete including cost, Conveyance, royalty, taxes of all materials, labour T&P etc, complete as per direction of Engineer-in-charge.

565.92

426137

753

... More
DRAIN:

1

-

-

... More
Supplying & Filling foundation trenches , plinth & ditches with clean course river sand well watered and rammed in layers not exceeding 23 c.m. in depth with all lead and lift including cost, conveyance, loading, unloading, stacking,royalties and all taxes of sand,cost & conveyance of water, cost of all Labour,labour cess,T&P required for the work etc. complete in all respect as directed by the Engineer- in -charge.

193.3

61991

320.7

... More
Providing and laying Plain cement concrete of proportion(1:3:6) in foundation and floors(i.e. below the base course of the flooring) using cement, 40mm. Size crusher broken H.G.Metal and screened and washed sharp river sand for mortar of approved quality and from approved quarry inclduign hoisting, lowering and laying concrete to the required level, ramming,watering and curing etc. completek to required levels, laid in layers not exceeding 15cm thick in each layer including cost, conveyance, loading, unloading,royalities and taxes of all materials, cost of all labour,T&P required for the work including shoring,shuttering anddewatering(if required)including hire and running charges of water pump required for the work etc. complete in all respect as directed by the Engineer-in-charge.

38.1

151653

3980.4

... More
Back filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5m.

99.17

9788

98.7

... More
Providing and laying in position ready mixed M-25 grade concrete having compressive strength at 28 days test not less than 250 kg/ sq.cm for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying , including the cost of centering, shuttering finishing and excluding reinforcement including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, and hoisting, lowering, laying and compacting concrete, watering and curing and finishing the exposed surfaces smooth with cost, conveyance, royalties, taxes of all materials with all labour,Labour cess and T&P required for the work improve workability without impairing strength and durability as per direction of the Engineer - in - charge.

1

-

-

... More
Foundation

31.8

155584

4892.6

... More
RCC wall

63.6

410251

6450.5

... More
Cover slab

31.8

258788

8138

... More
Cutting,straightening coiled or bent up HYSD/TMT Reinfocement Bars welding or jointing if necessary ,bending, binding,tying the grills as required for R.C.C. works,providing Fan Hooks where necessary and hoising,lowering and placing the same tin proper position according to the approved eesigns and drawings in all floors including cost, conveyance, loading, unloading and taxes or HYSD/TMT Reinforcement Bars and Binding wieres of 18 to 20 gauge required for the work cost of all labour,T&P and scaffolding complete in all respect as directed by the Engineer-in-charge(Payment will be made according to the actual/proper weight of HYSD/TMT Reinforcement Bars and Binding wires consumed in the particular work only).

114.4

733075

6408

... More
SECURITY SHED:

1

-

-

... More
Earth work in excavation IN ALL KINDS OF SOILS by manual means overareas (exceeding 30 cm in depth, 1.5 m in width as well as 10sqm on plan) inculding disposal of excavated earth up to 50 m and lift upto 1.5m with all lead and lift including shoring, shuttering & dewatering (if required) with cost of all Labour, Labour cess ,Hire & Running charges of the water pumps, Sundries, T & P required for the work complete as directed by the Engineer- in- charge.

38.88

5754

148

... More
Supplying & Filling foundation trenches , plinth & ditches with clean course river sand well watered and rammed in layers not exceeding 23 c.m. in depth with all lead and lift including cost, conveyance, loading, unloading, stacking,royalties and all taxes of sand,cost & conveyance of water, cost of all Labour,labour cess,T&P required for the work etc. complete in all respect as directed by the Engineer- in -charge.

24.68

7914

320.7

... More
Providing and laying Plain cement concrete of proportion(1:3:6) in foundation and floors(i.e. below the base course of the flooring) using cement, 40mm. Size crusher broken H.G.Metal and screened and washed sharp river sand for mortar of approved quality and from approved quarry inclduign hoisting, lowering and laying concrete to the required level, ramming,watering and curing etc. completek to required levels, laid in layers not exceeding 15cm thick in each layer including cost, conveyance, loading, unloading,royalities and taxes of all materials, cost of all labour,T&P required for the work including shoring,shuttering anddewatering(if required)including hire and running charges of water pump required for the work etc. complete in all respect as directed by the Engineer-in-charge.

4.42

17593

3980.4

... More
Back filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5m.

7.35

725

98.7

... More
Disposal of surplus excavted materials by mechanical means from the work side etc. complete. upto 5km. Lead

31.52

4765

151.17

... More
Providing and laying in position ready mixed M-25 grade concrete having compressive strength at 28 days test not less than 250 kg/ sq.cm for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying , including the cost of centering, shuttering finishing and excluding reinforcement including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, and hoisting, lowering, laying and compacting concrete, watering and curing and finishing the exposed surfaces smooth with cost, conveyance, royalties, taxes of all materials with all labour,Labour cess and T&P required for the work improve workability without impairing strength and durability as per direction of the Engineer - in - charge.

1

1

1

... More
Foundation

7.2

35226

4892.6

... More
Column from footing top to NGL

0.68

6175

9082.2

... More
Column from NGL to PL

0.22

1998

9082.2

... More
RCC in plinth beam

1.92

9974

5195

... More
RCC in column from PL to Ground floor roof lvl

2.16

19617

9082.2

... More
RCC in Roof beam

1.12

10172

9082.2

... More
RCC in roof slab

2.9

23600

8138

... More
Lintel

0.72

5590

7764.6

0.44

3416

7764.6

... More
Chajja

2.44

1661

680.8

... More
Cutting,straightening coiled or bent up HYSD/TMT Reinfocement Bars welding or jointing if necessary ,bending, binding,tying the grills as required for R.C.C. works,providing Fan Hooks where necessary and hoising,lowering and placing the same tin proper position according to the approved eesigns and drawings in all floors including cost, conveyance, loading, unloading and taxes or HYSD/TMT Reinforcement Bars and Binding wieres of 18 to 20 gauge required for the work cost of all labour,T&P and scaffolding complete in all respect as directed by the Engineer-in-charge(Payment will be made according to the actual/proper weight of HYSD/TMT Reinforcement Bars and Binding wires consumed in the particular work only)

16.4

105091

6408

... More
Fly Ash Brick Masonry in cement mortar of mix (1:6) using Fly Ash bricks of size 25c.m x 12 c.m x 8 c.m in Foundation & Plinth having crushing strength not less than 75 kg per square c.m. with cement and screened & washed sharp sand for mortar after immersing the bricks for 6 (Six) hours in water before use in works with all necessary projections, splays cutting, circular moulding, corbelling, chamfering, watering and curing etc. including cost, coveyance, stacking, loading, unloading, royalties , all taxes ,cost of all labour,Labour cess ,scaffolding, sundries and T&P required for the works etc. complete in all respect as directed by the Engineer-in-charge.

1.44

5029

3492.6

... More
Aerated Autoclaved Concrete blocks of size 625mmX200mmX200mm having compressive strength more than 4N/ sqmm confirming to IS:2185-Part-3-1984 & IS:6441-1972 of Lean/Aerolite or equivalent products in cement mortar of mix (1:6) using cement of approved quality, screened & washed sand for use in super structure including splays cutting, circular moulding , corbrlling, champering & similar such type of works, watering & curing etc. including cost, conveyance, royalty, loading, unloading of all materials, cost of labour, scaffolding, sundries, T & P required for the works etc. complete in all respect as directed by the Engineer-in-charge.

10.68

43548

4077.53

... More
Providing 12mm. thick cement plaster in cement mortar or mix(1:6) in all floors at all height with cement & screened and washed sharp river sand for mortar and finished smooth to the rough surface of the brick masonary walls after racking out the joints (alongwith providing grooves wherever necessary) including watering and curing,rounding of corners etc. complete with cost, conveyance, loading, unloading, royalities and taxes of all materials,cost of all labour,T&P, and scaffolding required for the work etc. as directed by the Engineer-in-charge.(Outer side)

78.28

7843

100.2

... More
Providing 12mm. Thick cement plaster in cement mortar or mix(1:6) in all floors at all height with cement & screened and washed sharp river sand for mortar and finished smooth to the rough surface of the brick masonary walls after racking out the joints (alongwith providing grooves wherever necessary) including watering and curing,rounding of corners etc. complete with cost, conveyance, loading, unloading, royalities and taxes of all materials,cost of all labour,T&P, and scaffolding required for the work etc. as directed by the Engineer-in-charge. (Inside)

65.68

6581

100.2

... More
Providing 6 mm thick cement plaster in cement mortar of mix (1:4) at all height using screened & washed sharp river sand for mortar with approved quality of cement to the ceiling of the Roof Slab, Staircase, Beams, Columns,Landings, Railings,Chajja ,Fins ,Walls ,Jally and Shelves etc. including roughening, scraping, chiseling, cleaning, closed deep chipping with slurry treatment and finished smooth to all R.C.C. Surface including cost, conveyance, loading, unloading, royalties ,stacking and all taxes , cost of all Labour,Labour cess ,Sundries, T&P, Scaffolding, Watering, Curing etc. complete in all respect as directed by the Engineer- in- charge

22.86

2436

106.6

... More
Priming one coat with af approved quality of water bound cement primer of APPROVED make including cost, conveyance and taxes of all materials & cost ,conveyance taxes of all labour with T & P required etc complete in all respect as per the direction of the Eng.-in-charge

166.82

7239

43.4

... More
Wall painting two coats with plastic emulsion of approved quality of premium brand such as Asian/ Berger/ ICI paints or equivalent of approved quality & colour at all heights to the interior surface of the wall to make an even finished surface including sand papering, applying putty wherever necessary including cost, conveyance, loading, unloading, stacking, all taxes , cost of all Labour , Labour cess,scaffoldings, staging, sundries,T&P etc. required for the work complete as directed by the Engineer-in-charge.

88.54

5462

61.7

... More
Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm.

78.28

10489

134

... More
Providing vitrified tile flooring using vitrified tiles having thickness of 8mm to 10mm conforming to IS 13755 of 600mmx1200mm (Plain Ivory) (homogeneous) of premium quality in floors, treads on steps and landings on 20mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened and washed sharp sand for mortar and fixing with neat white cement slurry,grouting the joints with neat white cement slurry mixed with required quantities of pigments of approved make to match the shades of the vitrified tile if required , watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour,Labour cess , sundries, T&P required for the work, complete in all respect as per specification and direction of Engineer-in-charge.

18

19882

1104.6

... More
Providing vitrified tile in dado/ skirting using vitrified tiles having thickness of 8mm to 10mm conforming to IS 13755 of 600mmx1200mm, (Plain Ivory) (homogeneous) in dado/ skirting,riser of steps,wall on on 12mm thick bed of cement mortar of mix (1:3) laid in proper slope and gradient with screened and washed sharp sand for mortar and fixing with neat white cement slurry,grouting the joints with neat white cement slurry mixed with required quantities of pigments of approved make to match the shadesof the vitrified tile if required watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, Labour cess ,sundries, T&P required for the work, complete in all respect as per specification and direction of Engineer-in-charge.

3.6

4399

1222.2

... More
Dressed seasoned sal wood work framed and fixed(wrought and put up) in truses, purlins, frames of doors, windows, ventilator and beams, including cost, conveyance, loading, unloading, stacking, royalties , all taxes, cost of all Labour, Labour cess , T&P required for the work , Watering , Curing for required days , cleaning the flooring space manually etc. complete in all respect as directed by the Engineer-in-charge.

0.1

4499

44994.4

... More
Providing , fitting & fixing of 32mm thick flush door shutter with 32mm thick BWR block board and paisting 4 mm thick veneer to both sides with adhesive and polishing throughly to its both sides including fitting & fixing of all fixtures like godrej make ofice lock haveing model. No. 9168. Godrej make door clouser having model no- 8340. including cost of all materials, all labour, all T&P etc. required for the work complete in all respect as per the direction of the Engineer-in-Charge.

3.78

34322

9080

... More
Supplying, fitting and fixing of M.S grills, grill gates with top and bottom rails, steel windows, steel doors, steel frames for doors and windows ( as per I.S. specification and as per approved drawings ) in proper position in all floors and at all height including making holes to brick walls/ R.C.C structure/wood work etc. and making good to the damaged walls/ structures with cement concrete (1:2:4) with black hard crusher broken granite stone chips of 12mm to 20mm size ( 20mm size not to exceeds 25% ) including watering and curing including cost, conveyance, loading, unloading, stacking, royalties and taxes of all materials, cost of all Labour, Labour cess ,Sundries, T&P required for the work etc.complete as per the direction of Engineer in charge ( W.I. / M.S. windows grills, grill gates, collapsible gates with top and bottom rails, steel windows, steel doors, steel frames for doors and windows, staircase and parapet railings square bar along with required nos. of nails and screws and other required materials of approved quality and approved size shall be supplied by the contractor at his own cost.)

86.4

5063

58.6

... More
Painting two coats with synthetic enamel paint of approved colour, shade and brand on New wood/steel work in as required to give an even shade including an under coat of suitable primer of approved brand and manufacturer including cost of all materials with taxes and transportation, loading, unloading, scaffolding, all labour, Labour cess, sundries, T&P, etc. including filling gaps with putties, scrapping, sand papering and cleaning the surface to make free from rusts, dusts and oily substances before applying primer etc. complete.as per the direction of the Engineer-in-charge

9.94

1338

134.7

... More
Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealant shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Three track three panels sliding window with fly proof SS wire mesh (Two nos. glazed & one no. wire mesh panels) made of (small series) frame 92 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area of window upto 1.75 sqm).

2.8

20985

7494.71

... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge . With float glass panes of 5 mm thickness

2.8

2441

872.08

... More
2.5 cm thick grading concrete (1:2:2) on roof slab with 6mm size HG chips including all cost, conveyance, royalty & taxes etc.comp.to work site for new work as per the specification approved by the department & direction of E.I.C

23.12

5289

228.8



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.