Military Engineer Services Tender

Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Eprocure
Opening Date5 Sep 2024
Closing Date26 Sep 2024
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
S & F in 1.00 mm thick mild steel rolling shutter strips duly pressed on both ends of vertical sides for interlocking locks for the required length of existing shutter as directed by Engg-in-Charge

48

-

-

... More
S&F heavy duty (C-class) pipe required to roll the rolling shutter over it of dia as required at site exc 50mm but nexc 100mm including necessary drilling , making key by shapers and nuts, bolts, washers as requird

12

-

-

... More
S&F in Safety lever locks mild steel with 4 levers for rolling shutters complete all as specified and directed.

0.5

-

-

... More
S&F in Ball bearing for rolling shutters complete all as specified and directed.

20

-

-

... More
M & L for preparation of new steel/iron surfaces exceeding 10cm width or girthand applying two coats of synthetic enamelled paint over a coat of red oxide primer including complete all as specified and directed.

96

-

-

... More
M&L for complete removing of old decorated surfaces of wall applying two coat of cement base paint and one coat primer complete all speciified and directedall as specified.

96

-

-

... More
Taking down and refixing in the same opening steel rolling shutter including oiling and greasing to required necessary fitting to functionall shutters as required bush, Spring. MS pipe , rod .lock. ball bearing, top cover, anchoring rod, hasp and staple and push pull or gear operating system , bevel gear box and crank handle etc complete all as specified.and directed.(area of rolling shutters exc 6 sqm but n. exc. 12 Sqm each ) (Note:- Necessary constituent items required during repair of rolling shutter shall be paid seperately in item No. 05,06,07,08 as given above .)

12

-

-

... More
M & L for preparation of old steel/iron surfaces exceeding 10cm width or girth and applying two coats of synthetic enamelled paint including complete all as specified and directed.

410

-

-

... More
Design,Supply and installation & commissioning of 60 KW DC dual gun fast EV charger maximum output power rating 60KW,Output DC voltage rating 200-1000VDC,outlet configuration-Dual Gun/CCS-2,max output current 200A,simultaneous charging DC power class HPC60(60kx/200A).Main inputs:-Input voltage 380/400/415 Vac,input voltage range 320 VAC-520VAC,Network connection-TN-S,AC wiring(3Ph(L1,L2,L3,N,PE),AC Power rating ~110A,65KVA @380VAC,Input Frequency(nominal) 50/60Hz,input Frequency Range 45-65Hz,THD5%(Nominal Input &50%,_ load100%,Power factor 0.98,Leakage Current30mA,Short Circuit Current Rating ~25 KA,Standby power 25Watt(@nom.Voltage), Backup battery-90Minutes(only forcontrollers not for charging)Protection and safety:-Surge protection-Integrated-IEC61000-4-5,Over Current-DC Output:202A,under voltage :-AC input:285 Vac phase to Phase,over voltage AC input:505 Vac Ph to Ph,over Tem:-Auto de-rated above 50 degree centi grade ambient,cut off at 75 degree ceti grade,over voltage cat-III,User interface and comms:-Display 7" TFT LCD Touch screen, Support language-English,Emergency switch-Available(Red mushroom push button)charge option/user Auth-RFID,Mobile app,OTP,QR Code,energy metering-included,visual indication(LED)-Presence of supply,state of charging,Error,RFID-MIFARE-ISO/IEC14443A/B,Connectivity-internet access via ethernet,modem 4G LTE,Communication protocol-OCPP v1.6j. Configuration:- Software update- OTA (Over the air)via OCPP server,Control and set up-OCPP v1.6j,local (passcode controlled). Mechanical:- Ingress Protection IP-54 acc.IEC 60529,Impact Resistance-IK10acc.IEC 62262, Dimensions(H*W*D)-1650*610*200mm,weight-125 kgs Approx,Charging cable length - 5 meters(standard Length),material- Texture finish power coating SECC,Mounting:-floor,cooling:-Forced Air(variable speed).Environmental:-Operating tep -30 degree centi grade to 75 degree centi grade(linear de-rating above 50 degree 50 degree centi grade),storage tem:--40 degree centigrade to 80 degree centi grade,altitude 2,000 meters(de-rating above 2,000 meters),Humidity(non condensing):-55 to 95%.Standards/Certifications:-Safety:-IEC-61851-1;IEC61851-21-2;IEC61851-23;IEC61851-24;IEC62196-1;IEC62196-2;IEC62196-3;IEC61000, Other -ARAI(AIS138 Part-2 Under Process), vehicle Communication-DIN70121,ISO15118,IEC61851.Quality:-Mean time between failure:- 150,000 hours,Mean time to repair:-1 hour on arrival at site,Design life:-10 years,Warranty:-1 year(standard extension available) Note-1:- Including providing monograms,symbol,instructions,brand advatise senthetic nylon colour phamplets,DOs and Dont's incl proper fixing arrangements etc without extra cost as per OEM directions/Recommendations.2. Making proper charging station as per OEM directions/norms connected necessary items measured and paid separately.Make:-- Terra Motors Charging Solutions Pvt Ltd, Model No.TCI60DC2GSL For 4 wheeler.

1

-

-

... More
Design,Supply and installation & commissioning of 4 wheeler, 22 KW, AC, slow charging, EV charger maximum output power rating 22KW,Output AC voltage rating 415 volts,50Hz, 5 wires( L1+L2+L3+N+PE),Output current type 415 volts,32Amps,no of outputs-01 Nos,Output cunnector rating -IEC62196/AC type-2,Ambient temperature-20 degree centi grade 55 degree centigrade,storage temperature 0 to 60 degree centi grade,humidity -5% to 95% non-condensing,display TFT screen 43'' push button,Emergency push button,visual indication supply /errors/state of charge,user authentication,using mobile application or QR code or RFID card or password login,surge protection,over current protection,under voltage protection,charger&CMS software-DCPP V1.6 or higher version,communication ethernet/wifi/gsm,IP-54,Charging cable length- 5 mtr,mounting type-wall/pole/any steel structure,all weather type enclosure, rating of charging capacity-7.4kw to 22 kw complete all as specified and directed.Make:- Terra Motors Charging Solutions Pvt Ltd, Model No.TCI 22 ACT2G For 4 wheeler.

1

-

-

... More
Design,Supply and installation & commissioning of 2/3 wheeler,3 pin, 3.3 KW, AC slow charging, EV charger maximum output power rating 3.3 KW,Output AC voltage rating 240 volts,50Hz, Output current type 220-240 volts,16 Amps,simultaneous EV charging qty-01 vehicle(3 -Pin socket),energy metering -class1(+1%),AC wiring single phase,earth fault detection,electrical safety-IEC60898-1,Tamper proof,emergency stop button,MCB, Surge protection, over currevt protection,under voltage, bluetoth,WiFi,GSM2G,Socket type/connector type-AC-001,IOT Enabled, metal body material enclosure,screen Display complete all as specified and directed..Make:- Terra Model:- KIWAMI/METAL-TCI-3.3AC,3 PIN for 2w/3wheeler 3.3 kw slow charging.

1

-

-

... More
Supply,Install,Testing and Commissioning of step down 11 KV transformer,level-2,Voltage rating 11KV/0.433 Volts,out door type of capacity 100 KVA,,3 Phase,4 Wire,50 Hz, oil cooled, core type, floor mounted, Delta/star connected maximum losses as defined in vector group DYN 11,Double copper wound ONAN manual type off load tap changing facility on HT side to vary secondary voltage from +/- 7.5 % in steps of 2.5 % continuous rating of capacity 100 KVA incl cable end box on both HT & LT side .The transformer shall be completed with all standard fittings and accessories, guages and including providing first fill transformer oil as as per indication level etc and confirming to IS :1180 and fittings and accessories of transformers shall confirm to IS 3639,335-1996 as amended and duly mounted on rollers as per load bearing capacity of transformer and the transformer shall have the following fittings/accessories fitted complete all as specified and directed.(i) HV Primary side consisting of 03 Nos porcelain insulated bushing with brass bushing rods and nuts,bolts and washersand 01 No cable end box as per OEM guage.(ii) LV Secondary side cosisting of 04 Nos porcelain insulated busthing with brass bushing rods and nuts,bolts and washers and 01 No cable end box as per OEM guage.(iii) Rating plate and terminal marking plate of HT/LT sides.(iv) Two earthing terminals for body earthing and two additional for neutral brought out on a bushing.(v) One number Thermometer dail type vapour presure type having range 0-120 degree centigrade with maxiumum temperature indicator and re-setting device to maximium tempratur including needle of temprature guage:max reading painted terminal.(vi) Lifting Lugs. (vii) Dehydrating silicagel breather. (viii) Oil level indicator with minium and maximum marking. (ix) Cooling Radiator.(x) Thermometer pocket.(x) Thermometer pocket. (xi) Drain valve with plug or cover plate. (xii) Conservator tank.(xiii) Oil filling hole with cover including funnel.(xiv) Air release device/plug.(xv) Thermometer 100 mm dia/stem type with metal guard having maximum temperature indication with resetting devices for transformer. (xvi) Winding temperature indicator.(xvii) Air release device for transformer.(xviii) First fill of suitable grade transformer oil confirming to IS and tested upto 60KV die electric strength.Make:- Indian transformers and electricals Pvt Ltd Gurgaon/ SEIMENS / SCHNEIDER / ABB or equivalent approved make.Note 1:- Information plate /Technical data plate as laid down in para 15.2 and 15.3 as per IS.Note 2:- Including making PCC foundation for transformer of size of 2.0 mtr X 2.0 mtr X 1.30 mtr (below ground level 0.3 mtr and above ground level 01 mtr and incl providing GI cattle fencing up to 1.50 mtr height all-around up to 2.5 mtr width from the transformer foundation corner to fence and suitable GI gate and locking arrangements complete all as directed by Engr-in-Charge.Note-3:- Exc,RFR,PCC and GI metal fencing with gate items will be measured and paid separately in relavent items.

1

-

-

... More
Supply, Install, Testing and Commissioning of 11/12 KV, Load Break Switch (LBS) , 3 Pole, incl providig dropout fuse units assembly with suitable fuses,Rating capacity 630 Amps,50 Hz which confirms to IEC 62271-1 standards Outdoor type in CRCA powder coated steel enclosure, 3 mm thick and the main frame is welded in steel structures fabricated load break switche Panel.The unique arc quenching mechanism makes it capable of breaking normal loads and fault loads.This can be operated on loads up to 1 MVA with epoxy insulators suitable rating, HT three pole busbar of rating 1.5 times capacity of LBS , double switch blades,forged contacts with arc quenching chamber, lagging pin and loop less current path. The nylon/FRP insulaton makes the switch light weight with greater electrical safety and mechanical strength load break switch panel and the contacts are mounted on epoxy insulators and operated the switch is also provided with stored energy tripping device and tripping intiantion by means of fuses rated short circuit making capacity upto 20 KA (RMS) 50 KA (PEAK) and make/break upto 630 Amps and mechanically interlocked earth switch and manually operated mechanical system and incoming and outgoing cable entries with necessarybase foundation in PCC 1:2:4 and the Manufactured shall be CPRI norms followed and drawings/circuit layout approval by Engr-in-Charge.Make:- Transguard/Maxwell/PCE/Power tech or equivalent approved make.

1

-

-

... More
M&L for galvanised iron metal fencing for 11 KV substation and including providing necessary fabrication work,welding, & drilling work,bending,cutting,nuts,bolts and washers etc for transformer fencing and gate with locking arrangements and necessary galavanised 100mm GI channels of length 2 meters heigh incl errection of channels 1.0 mtr below ground level and 1.5 mtr above ground level with proper foundation and coping two coats of red oxide primer and two coats of anti-corrosive silver paint complete all as specified and directed.

9

-

-

... More
Supply, laying & testing 11 KV grade cable XLPE/PVC insulated, screened, PVC bedded,galvanized steel strip or wire armoured, electric power cables (heavy duty ) with stranded aluminium conductor,11000 volts (Earthed) grade, of cross sectional area 95 sqmm,3 core complete all as specified and directed.Make:-Havells india Ltd/Polycab wires Pvt Ltd/Gloster cables Ltd(Note:-(i) Excavation,Earth work,sand cushioning,cable covers and cable protection pipes shall be measured and paid separately.)(ii) The cable shall be in one length unless otherwise directed by GE.

45

-

-

... More
Supply and fix cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 to120 sqmm complete all as specified and directed.Make: Raychem/M-Seal/Denson

1

-

-

... More
Supply and fix cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 to185 sqmm complete all as specified and directed.Make: Raychem/M-Seal/Denson

1

-

-

... More
Supply, install, testing and commissinoning LT panel board outdoor type of size 1400 mm long X1200 mm width X 600mm thickness(depth) with double door type suitable for working on 3 phase ,4 wire ,415 volts, AC ,50Hz, ,cubicle and shall have air ventilation arrangement,IP-54 Protection, floor mounted, free standing, dust and vermin proof, made out of 3.15 mm thick at outer sheet and 2.0 mm thick at internal compartments CRCA sheet and necessary angle/flat irons duly powder coated, hinged doors with rubber gasket, handles.Panel shall have front and rear opening,locking arrangement,cable alleys,cable entry holes for incoming and out going cables,busbar chamber and switch gear compartment,see through glass for indicator lamps, control copper wiring & safety fuses,earthing terminals,affix danger notice plate,aluminium busbar fixed on DMC/SMC insulators and all incoming and outgoing internal connection should be connected suitable rating aluminium bus bars only with RYB color code sleeves/taps, and the panel will be mounted on 50mmX50mmX6mm GI angle iron base frame of height 45 CM above GL as per site requirement and below GL 45 CM and including connecting up of existing incoming and out going cables by using new aluminium lugs and cable gland and connecting of earth strip and providing civil work/PCC foundation (1:2:4) type B1 with studs,bolts,nuts & washers as per site requirement. And complete all as specified and directed and including comprising of following:-Note:- (i) LT panel board manufactured by any manufacturer should be followed by CPRI norms/certified. (ii)The contractor shall be arranged General (SLD), circuit lay out drawings & Switch gear items makes submitted for prior approval by the Accepting Officer/Engineer -in-charge before procurement/ordering.(i) MCCB 250 Amps,4 pole, 35/36KA, 415 Volts thermal magnetic based-01 Nos incl spreader links of suitable ratings Make:-ABB/ Siemens/Schneider/Havells.(ii) MCCB 200 Amps,4 pole, 25KA, 415 Volts thermal magnetic based-01Nos incl spreader links of suitable ratings Make:-ABB/ Siemens/Schneider/Havells.(iii) MCCB 160 Amps,4 pole, 25KA, 415 Volts thermal magnetic based-02 Nos incl spreader links of suitable ratings Make:-ABB/ Siemens/Schneider/Havells.(iv) MCCB 100 Amps,4 pole, 16KA, 415 Volts thermal magnetic based-01 Nos and 01 X spare compartments for MCCB incl spreader links of suitable ratings Make:-ABB/ Siemens/Schneider/Havells.(v) MCCB 63 Amps,4 pole, 16KA, 415 Volts thermal magnetic based-01 Nos 01 X spare compartments for MCCB incl spreader links of suitable ratingsMake:-ABB/ Siemens/Schneider/Havells.(vi) MCB 32 Amps,SPN, 10KA, 240 Volts thermal magnetic based-03 Nos Make:-ABB/ Siemens/Schneider/Havells.(vii) R,Y,B Phase indicating lamp -01 Set Make:- Jigo/L&T.(viii) Digital Ammeter (0 amps to 500 Amps) selector switch -01 No.Make:-AE/Selec.(ix) Ammeter Selector switch -01 No.Make:-AE/Kaycee.(x) 400/5A current transformer -03 No's Make:-Kappa.(xi) Digital Voltmeter( 0Volts to 500Volts)-01 No with ASS, Make:-AE/Kaycee.(xii) Volmeter selector switch -01 No with VSS Make:-AE /Kaycee.(xiii) Protection fuses& controll wiring -03 Nos Make:-Nippon.(xiv) Busbar aluminium TPN 400 amps rating suitable size -01 Set ( 04 Nos).

1

-

-

... More
M&L for danger notice plate of size 250 x 250mm and 1.6 mm thick galvanised steel plate,vitreous enammelled white, with letters,figures and conventional skull and bones in signal red colour and fixed with GI clamps,bolts and nuts of above size, for HT, 11000 volts grade complete all as specified and directed

1

-

-

... More
Material and labour for GI earth continuity strip of size 32x6 mm complete all as specified and directed.

16

-

-

... More
Material and labour for rubber mat of 1 mtr x 2 mtr x19 mm complete all as specified and directed

1

-

-

... More
Supply, laying & testing PVC insulated armoured, heavy duty electric cable with stranded aluminium conductor,1100 volts of cross sectional area 25 sqmm,4 core including testing complete all as specified and directed.Make:-Havells/polycab/Anchor

30

-

-

... More
Supply, laying & testing PVC insulated armoured, heavy duty electric cable with stranded aluminium conductor,1100 volts of cross sectional area 70 sqmm,4 core including testing complete all as specified and directed.Make:-Havells/polycab/Anchor

40

-

-

... More
Supply and providing river sand for cushioning with dry clean sand 15 cm below cable and 8 cm above the under ground cables and necessary fillings in the trenches and punning to provide required cover complete all as specified and directed.

2

-

-

... More
Excavation in trenches soft loose soil exceeding 1.5 mtr depth and not exc 3.0 mtr depth and not exceeding 1.5 mtr wide for foundations etc and getting out in soft loose soil complete all as specified and directed.

2

-

-

... More
Excavation in trenches , not exceeding 1.5 mtr wide and not exc 1.5 mtr depth for laying of cables, pipe lines, protection pipes and foundations etc and getting out in soft /loose soil complete all as specified and directed.

8

-

-

... More
Returning filling in soil including spreading leveling watering and well rammimg in layer n exc 25 cm complete all as specified and directed

4

-

-

... More
Removing excavated soil not exc 50 mtr ant depositing where directed at a level not exc 1.5 mtr above the starting point all as specified and directed

4

-

-

... More
Material and labour for PCC 1:4:8 type D2 using (40 mm graded stone aggregate) for making good of road cutting portion, mass concrete, filling of foundations etc including necessary use and waste of form work complete all as specified and directed

5

-

-

... More
Material and labour for PCC 1:3:6 type C2 using (40 mm graded stone aggregate) for making good of road cutting portion mass concrete, filling of foundations etc including necessary use and waste of form work complete all as specified and directed

5

-

-

... More
Material and labour for PCC 1:2:4 type B1 using (20 mm graded stone aggregate) for making foundation/base plinth and pole coping, foundation etc including necessary use and waste of form work complete all as specified and directed.

5

-

-

... More
Material and labour for earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directely in ground vertically ( earth pit not less than 2.25 metres deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including galvanised iron strip of size 32 X 6 mm from earth electrode to test point or up to 7.5mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate no 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade,GI funnel with wire mesh,including char coal, salt packed all around the earth electrode plate in layers,PCC earth pit chamber 1:3:6 type C1,RCC cover 1:2:4 type B1, including excavation,earth work in any strata and returning filling, removal of surplus soil and testing for required value complete all as specified and directed.

10

-

-

... More
Supply and fixing in repairs modular switch 1 way,16Amps,1module,240V, ISI Marked and suitable for existing type as per site requirement and including removing old usnv items complete all as specified and directed.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.