Military Engineer Services Tender
Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.
Costs
EMD
₹ 40,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_691138_1Bid Award Id
ViewTender No
8538/BBSR/04/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Material and labour for fixing XLPE insulated, armoured heavy duty electric service cable with aluminium conductor, 1100 volts grade, cross-sectional area 6 sq mm 4 core, including taking down old UNSV cable complete all as specified and directed.
400
-
-
... More
Excavation in trenches, n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation or taking up / down electrical cables / pipe. and getting out in soft/loose soil concrete complete all as specified and directed.
59
-
-
... More
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick in soft/loose soil complete all as specified and directed.
48
-
-
... More
Removing excavated spoil to a distance n.exc. 50 m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
11
-
-
... More
M&L for sand cushion for under ground cable protection and consolidated and compacted with clean dry river sand complete all as specified and directed.
Note- Punned thickness will be measured at the time of measurement and payment.
8
-
-
... More
S&F bricks fly ash bricks locally available best quality laid in trenches over sand cushioning for cable protection complete all as specified and directed.
1600
-
-
... More
S&F in replacement 200 W LED highbay light fitting energy efficient light distribution with IP66 protection including all necessary clamps, nuts , bolts or fixing arrangement complete all as specified and directed.
20
-
-
... More
S&F in replacement street light 45W LED complete with die cast aluminium housing complete all internal protectionand driver circuits and lumen efficasy greater than 120lumens per watt complete all as specified and directed.
55
-
-
... More
S&F in replacement street light brackets made with40mm GI pipe (approx 2.1m length) with necessary febrication work to make decorative brackets with black paint on primer and necessary clamps for fixing on poles complete all as specified and directed. (Note : The bracket design will be directed by Eng-in-Charge)
55
-
-
... More
S&F in replacement flood light 100 W LED complete with internal driver and protection circuits and aluminium die cast housing and lumens not less than 130 Lumens per watt complete all as specified and directed.
40
-
-
... More
S&F in replacement decorative gate light LED 40W suitable for fixing on 40mm GI pipe complete with all internal driver and protection circuit complete all as specified and directed.
20
-
-
... More
S&F in replacement PVC insulated 1.5 sqmm 3 core copper cable for connecting junction box to street light fitting, testing and commissioning complete all as specified and directed.
320
-
-
... More
S&F in replacement PVC insulated 2.5 sqmm 3 core copper cable for connecting junction box to street light fitting, testing and commissioning complete all as specified and directed.
300
-
-
... More
Repairing of streel light fittings complete with dismantling from poles, repairing with necessary drivers/LED replacement and refixing on pole upto 60W complete all as specified and directed.
100
-
-
... More
Repairing of streel light fittings complete with dismantling from poles, repairing with necessary drivers/LED replacement and refixing on pole above 60 watt and upto 120W complete all as specified and directed.
60
-
-
... More
Repairing of flood light fittings complete with dismantling from poles, repairing with necessary drivers/LED replacement and refixing on pole above 120W and upto 200W complete all as specified and directed.
36
-
-
... More
S&F in replacement sheet metal enclosure TPN DB 415 volts 6 way double door type with 200amps rated bus bar for fixing MCB complete all as specified and directed.
7
-
-
... More
S&F in replacement MCB SPN 240 volts 6 to 32 Amps, 10 kA, 'C' curve complete all as specified and directed.
10
-
-
... More
S&F in replacement MCB TPN pole 415 volts 63 Amps, 10 kA, 'C' curve complete all as specified and directed.
7
-
-
... More
S&F in replacement MCB TPN pole 415 volts 100 Amps, 10 kA, 'C' curve complete all as specified and directed.
3
-
-
... More
S&F in replacement MCB SP 240 volts 6 to 32 Amps, 10 kA, 'C' curve complete all as specified and directed.
22
-
-
... More
S&F in replacement PVC insulated 4 core 2.5 Sq mm stranded copper conductor cable for connecting junction box to street light fitting, testing and commissioning complete all as specified and directed.
200
-
-
... More
Supply and fixing in replacement 250 Amp MCCB 4pole, 36 kA breaking capacity Adjustable Thermal & Fixed Magnetic complete all as specified and directed.
2
-
-
... More
Supply and fixing in replacement 160 Amp MCCB 4pole, 25 kA breaking capacity Adjustable Thermal & Fixed Magnetic complete all as specified and directed.
2
-
-
... More
Supply and fixing in replacement 100 Amp MCCB 4pole, 25 kA breaking capacity Adjustable Thermal & Fixed Magnetic complete all as specified and directed.
1
-
-
... More
S&F in replacement 63 Amps 4 way bus bar chamber with necessary fixing arrangement such as jointing material, nuts, bolts, washers and clamps etc complete all as specified and directed.
5
-
-
... More
S&F in replacement 100 Amps 4 way bus bar chamber with necessary fixing arrangement such as jointing material, nuts, bolts, washers and clamps etc complete all as specified and directed.
4
-
-
... More
Labour for Repair/maintainace of LT cable faults by disconnecting and taking out old existing LT cable of any sizes, in any position from trench/duct/panel and removing/excavating the outer surface of cable, examining cable and joints for defects and ascertaining suitability of cable for reuse, meggering, cutting out the defective portion of cable/joint, including taking out old serviceble PCC cable covers/Bricks or GI pipe of any type/size and relaying the cable with old serviceable bricks/PCC cable covers after repair/replacement of cable / jointing kit of any make or size of existing then make good the excavated area by returning/filling the same complete all as specified & directed. Note: (a) Using of new GI pipe or new jointing kit shall be deemed to included in quoted rate. (b) Excavation, refilling and sand/cable covers as used shall be deemed to included in quoted rate. (c) Irrespective of nature of complaint fault identification and necessary minor accessories as tape/lugs/nuts bolts/testing through test lamp or meggering for any fault identification and securing cables or connected switch gear after defect rectification is deemed to be included in the scope. (d) Necessary tools /safety eqpts like hand gloves/discharge tools/helmet/torch/gum boots and other safety equipments as per standard practice is to be deemed to be included and proovided by contractor. (e) The fuse of call/breakdown and defect identification to be attended immediately within 2 hrs and process for proper defect identification should be completed in continuation alongwith any further workmen or equipment required as defect rectification being essential service in nature and the cost is deemed to be included in scope of work and also as directed. (f) Contractor is completely responsible for the safety of manpower employed by him.(g) The contactor need to arrange necessary skilled manpower immediately to restore the essential electrical services.