Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.
Costs
EMD
₹ 66,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_682174_1Tender No
8985Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Transformer capacity 300KVA to 400 KVA
4
-
-
Transformer capacity 500KVA to 630 KVA
2
-
-
Material and Labors for shifting of transformer from one area to another area of ITR and placing in position including installation testing and commissoning as per site requirement complete all as specified and directed.
2
-
-
M&L for lightning arresters suitable voltage 11000 volts expulsion type complete with all fittings, transmission class,discharge capacity 65 kilo amp. Make :JAIPURIA/RASHTRIYA/oblum/Alstom
4
-
-
Supply only digital over current and earth fault relay operated on 85-275 volts Aux supply and sec current of 5 Amps including necessary connection initial calibration and testing complete all as directed by Engineer-in-Charge.Make: Ashida/GE/ECE
2
-
-
Disconnection and taking out of unserviceable supervision relay any type from existing HT VCB panel in any position and supplying, installation, commissioning & testing of electronic type Product cod trip supervision relay 24 V to 110 V DC. Make - Cromption Model No. TH 30
7
-
-
S&F Digital type Volt meter 0-15KV, PT operated 110 Volt input complete all as specified and directed. Make - AE/ Nippen
6
-
-
S&F Digital type Ampmeter CT operated, 5 Amp input complete all as specified and directed. Make - AE/ Nippen
8
-
-
M&L for Filtration and Dehydration of transformer oil of Transformers / OCBs / Oil switches at different location of ITR Chandipur with filtration cum dehydration machine to achieve desired level of di electric strength of transformer oil including testing complete as specified and all as directed by engineer in charge.
Note- The quoted rate shall deem to incl for the cost of centrifuging the transformer oil by means of electrical operated centrifuging machine .
(ii) The contrator shall test the di electric strength of oil of each transformer before dehydration & filtration and after completion of dehydration and filtration process he shall submit record of the same. Each sample of oil shall be tested with a transformer oil test machine at site in presence of concerned JE/ Engr- in- Charge. The contractor will have to arrange correctly calibrated Transformer Oil Test machine. for this purpose. (iii) Old unserviceable oil obtained if any shall be deposited in the MES store complete all as directed by Engr- in- Charge .
10500
-
-
Supply only insulation oil in Transformer Oil tank having Di-electric strength not less than 60 KV at 2.5 mm electrode gap for 60 sec confirming to IS-335 and ISI marked all as spsecified and directed by Engineer-in-Charge. Make: POWER/GULF
950
-
-
Supply and filling in repair/replacement of silica gel in existing breather assembly.
Make : MB Supplier/Pooja industries/Goyal electric works
10
-
-
Supply & fixing in repair/replacement of breather for 400/500 KVA Transformer.
Make : MB Supplier/Pooja industries/Goyal electric works
8
-
-
Supply & fixing in repair/replacement of breather for 200/250 KVA Transformer.
Make : MB Supplier/Pooja industries/Goyal electric works
10
-
-
S/F in replacement of HT bushing with stud, brass terminal 6 Nos.brass nuts and washers, gaskets, insulator etc suitable for (11/0.433 KV) 50 KVA TO 630 KVA Transformer complete in all respect & all specified. Make : Neelachal Transformers Pvt Ltd/Power & Distribution transformer
8
-
-
S/F in replacement of .LT bushing with stud, brass terminal 6 Nos.brass nuts and washers, gaskets, insulator etc suitable for 50 KVA TO 300 KVA Transformer complete in all respect & all specified. Make : Neelachal Transformers Pvt Ltd/Power & Distribution transformer
8
-
-
Supply and fix Temperature gauge suitable for transformer of capacity above 100 KVA and upto 400 KVA complete all as specified and as directed.
3
-
-
All as per item No. 15 but suitable for transformer of capacity 500 KVA to 630 KVA
4
-
-
Disconnection and taking out unserviceable distribution Transformer of capacity 250 KVA 11/0.415 KV from sub station No.- I and MRS for the following phase of worksspecified and directed:-
Note :-
(i) Cost of Supply and fixing of nuts, bolts, washers fevicol sleeves cotton tapes etc shall be deemed to be included in quoted rate.
(ii) Necessary test of Transformer shall be carried out by factory as per is in presence of MES representative and Test report shall be submitted to the department.
(iii) All item above are having tentative quantity and specification and may change as per ground requirment.
-
-
-
Dismantling the Transformer of 400/600 KVA, 11/0.415 KVA capacity and transporting the Transformer from Sub station to workshop and draining out oil and storing aside lifting of core and winding assembly, further dismantling and segregation of HT/LT serviceable and unserviceable winding, taking out old worn out insulator, separators set for strip, inspection and further necessary repair and carrying out cleaning of complete transformer, removing of all worn out gasket/Jointing materials, oil seals. Segregation of all serviceable spares/ accessories/ components for reuse and replacement of unserviceable spares/accessories/ components with new materials and reassembling and transporting the transformer to sub stn after carrying out repair including dehydration and testing and commissioning complete all as specified and directed.
3
-
-
Materials for HT/LT winding of Transformer super enameled copper wire/strip of appropriate cross section and turn as per existing all as directed.
180
-
-
Materials for re-insulation by wrapping with new insulation paper after taking down old burnt insulation including assembly and connection for 200/250 KVA, 11/0.433 KV Transformer all as specified and directed.
5
-
-
Carrying out replacement of all Gasket using rubber cork sheet of 6.0 mm thick including providing gasket cement adhesive all as specified and directed.
5
-
-
M&L for taking proper shut down, disconnecting incoming / out going cable, control cable from 11 KV OCB/VCB of any type and capacity upto 630 amps and carrying out complete servicing / overhauling, resetting of all electrical and mechanical parts for easy and proper operation, greasing of moving / revolving / sliding parts in VCB Panel, calibration of relays, meters incl thorough cleanining with air blower / vacuum cleaner, decarbonising & providing mineral jelly to all arcing contacts of the VCB panel, and serviceability check from local / remote control panel including replacement of unserviceable minor spare parts viz. nut / bolt / washer / connecting wire / insulation tape / sleeves etc complete including reassembling complete parts reconnecting incoming / outgoing cable, testing on load and all as specified and directed by Engr-in-Charge. Note- 1. Unserviceable items other than minor parts to be replaced will be meaured and paid seperately as supply only under revelent items in the schedule. However, cost of certain minor spares viz nut / bolt / washer / connecting wire / insulation tape / sleeves etc. if required shall deem to be included in the cost of repair of the item.
2. The spare parts to be replaced shall be of reputed brand / make and shall be of same type, design, specifications etc to match with the existing and as per the recommendation of OEM.
3. Complete servicing and calibration work shall be carried out by qualified and reputed service engineer only.
6
-
-
Supply only of following items for maintenance of OCB/VCB of 11 KV, 400/630 Amps capacity :-
-
-
-
Supply only VCB closing coil,Aux supply110V DC,24V DC,30VDC suitable of make - siemens
2
-
-
Supply only VCB triping coil Aux supply110V DC,24V DC,30VDCsuitable of make-Siemens & ABB
2
-
-
Supply only Bus bar spout L1,L2,L3 for 11KV VCB/OCBsuitable of make - Siemens & ABB
2
-
-
Supply only Spouts L2 suitable for VCB Make- Siemens & ABB
2
-
-
Supply only Spouts L3 suitable for VCB Make- Siemens & ABB
2
-
-
Supply only three phase 11 kv resin cast type PT with 3.15 amps fuse on primary side.
1
-
-
11 KV resin cast CT ratio -100/50/5 +5A
2
-
-
11 KV resin cast CT ratio -200/100/5A
2
-
-
Master trip relay(coil voltage= 110 DC) contact configuration 3 NO + 2- NC (H/R) Burden high
4
-
-
Three element voltage operated auxiliary relay (coil voltage = 110 V DC) contacts :2 NO (H/R) for each elements case size : 1/2 NH flag : Yes Make Ashida/Alstom
6
-
-
One phase digital ammeter (96 sqmm) -flush mounted (C1 : 0.5) Aux supply = 110 V AC
8
-
-
One phase digital voltmeter (96 sqmm) -flush mounted PT ratio : 11 KV /3 /110 V/3(C1 : 0.5) Aux supply = 110 V AC to measure line L-L voltage
8
-
-
Digital MFM meter (Aux supply = 110 V AC, Size 96 mm x 96 mm ,C1 : 0.55 RS -485 port on modbus.
1
-
-
Breker control switch TRIP- NEUTRAL -CLOSE, 25 AMP, 660 V AC having 1 TRIP & 1 CLOSE contact indicating plate size 75 x75 mm with marking TRIP-NEUTRAL CLOSE.
9
-
-
Supply only selector switch for local&remote 2pole2 way amp 10amps colour gray volts220V
3
-
-
Supply only Ammeter selector switch 3 way and off
4
-
-
Supply only Voltmeter selector switch (3 way and off) R-Y,Y-B,B-R off
4
-
-
Supply only Indication lamps
6
-
-
Supply only Base with fuse link -25 amps
4
-
-
Supply only MX0 22E type auxiliary contactor (2 -No+2-NC) supply voltage = 110 V DC
4
-
-
Supply only one nos anti condentation space heater
4
-
-
Supply only 7" thermostate
4
-
-
Supply only anti pumping relay suitable for Siemens make VCB
4
-
-
Supply only spring charging of motor aux supply
1
-
-
Supply only flower contact
2
-
-
Supply only vaccuum interrupter for 11 KV VCB
1
-
-
Supply only support insulator for 11 KV VCB/OCB
4
-
-
Supply only big gear assembly
1
-
-
Supply only rubber solute for VCB trolley bussing
6
-
-
Supply only limit switch for VCB.
2
-
-
M & L in replacement of wiring of IDMT relay/CT/trip relay complete with 2.5 sqmm copper flexible conductor cable including their numbering and make system serviceable complete testing of IDMT relay complete all as specified and directed.
4
-
-
Disconnecting and taking out existing unserviceable current transformer of any description and in any position and Supply, installation, commissioning and testing of cast resin type 11 KV current transformer having ratio of 100+50/5 A having protection core class 5P10, burden of 15 VA and metering core class 1.0 and burden of 15 VA breaking cap of 13.1 KV for 1.0 second all as specified and directed. (Make :- Jyoti /Skipper /Kappa/ Alstom/ Crompton greaves.)
2
-
-
Disconnecting and taking out existing unserviceable current transformer of any description and in any position and Supply, installation, commissioning and testing of cast resin type 11 KV current transformer having ratio of 200+100/5 A having protection core class 5P10, burden of 15 VA and metering core class 1.0 and burden of 15 VA breaking cap of 13.1 KV for 1.0 second all as specified and directed. (Make :- Jyoti /Skipper /Kappa/ Alstom/ Crompton greaves.)
1
-
-
M&L for MS cross arm , bracing supports , clamps and back plate fabricated from structural steel sections holding nut,bolts and washers including necessary welding , bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive two coat of synethetic enamel paint over a coat of red oxide primer complete including taking down old unserviceable MS cross arm complete all as directed.
2
-
-
Supply & fix jumper of two pole/four pole structure with aluminium conductor steel reinforced of any size on existing HT two pole/four pole structure using new aluminium binding wire including reconnecting all connections by means of suitable size lugs/thimbles including taking down old aluminium conductor jumper complete all as directed by Engr-in-Charge.
0.2
-
-
Supply, fixing , commissioning and testing in replacement of outdoor type , 11 KV gang operated switch with drop out fuse assay complete of current rating upto 400 Amps 4 insulator Vertical type triple pole each pole consisting of galvanized steel based HT insulator as per IS non ferrous knife and spring loaded contacts, arching horns of adequate section to break magnetizing current of the transformers horizontol Gi of adequate length for phase separation , adequate length of GI pipe operation from ground level and operating handle with locking arrangement complete in both OFF and ON positions. All ferrous parts hot dripped galvanized and non ferrous heavily tinned to with stand weather suitable for Vertical mounting on existing structure including taking out old us GOD complete all as specified and directed.Make:- Jaipuria/BHEL/Pactil
2
-
-
Supply, fixing , commissioning and testing in replacement of outdoor type , 11 KV gang operated switch with drop out fuse assay complete of current rating upto 200 Amps 4 insulator Vertical type triple pole each pole consisting of galvanized steel based HT insulator as per IS non ferrous knife and spring loaded contacts, arching horns of adequate section to break magnetizing current of the transformers vertical GI of adequate length for phase separation , adequate length of GI pipe operation from ground level and operating handle with locking arrangement complete in both OFF and ON positions. All ferrous parts hot dripped galvanized and non ferrous heavily tinned to with stand weather suitable for vertical mounting including taking out old GOD complete all as specified and directed.Make:- Jaipuria/BHEL/Pactil
2
-
-
Supplying ,fixing danger notice board of 1.6 mm thick mild steel sheet , viterous enamelled white , with letters , figures and conventional skull and bones in signal red colour and fixed with MS clamps , bolts for HT 25X20 cm size complete all as specified and directed.
15
-
-
M & L for painting of two pole/four pole structur including cross arms,chanel etc complete structure after scraping old paint with two coats synthetic aluminium paint after applying one coat of zinc oxide primer complete all as directed by Engr-in-Charge
8
-
-
M & L for painting of OCB's from inside and outside by applying two coats of synthetic enamel paint (Smoke grey) after scraping and removing old paint and writing SM/MES No., Incoming and outgoing details complete all as specified and directed by Engr in charge
12
-
-
M & L for calibration of earth fault relay ,and over load relay with accuracy of OCB/VCB and setting and testing the tripping system as directed by Engr-in-charge and servicing of OCB/VCB , cleaning the rust and dust of metal part and applying lubrication to all moving parts complete all as specified and directed by Engr-in-charge
10
-
-
M&L for painting in two coats with first quality of synthetic enamelled paint over a coat of red oxide primer after complete removal of existing finish to step up / step down transformer of capacity 50 to 500KVA incl writing of its corrosponding MES No / Sl No / maintenance date etc complete all as spd and as directed by Engr- in- Charge.(Note: Proper shutdown including dismantling of primary / secondary connections and refixing the same to be ensured)
22
-
-
M&L for post type, porceline, vitreous, brown insulator including one cast Iron post with nuts, bolts washers etc of tensile strength 2050 kg hight 254 mm, insulation part dia 176mm and pitch circle dia 76mm top and bottom as per IS 731, 2544 and 5350 sutable for 11 KV grade including taking down old insulator all as directed by Engineer-in-Charge Make : JAIPURIA/RASHTRIYA/oblum
15
-
-
M& L for Earthing complete with galvanised steel earth plate eletcrode of size 60x60cm x 6.0 mm thick electrode as buried directly in ground (earth pit not less than 3mtr below normal ground level connected to GI earth strip 32mm x 6mm thick by means of bolts nuts,check nuts and washers at complete etc all as shown in electrical plate No-3 of SSR part-1 connected to earthing test point all as specified or indicated including PCC pit in PCC(1:3:6) type CI cast iron frame 50mm thick pre cast RCC (1:1½ :3) nominal mix cover slab reinforced with 8mm dia mild steel bar including necessary excavation earth work in soft/loose soil and disposal of spoil to a distance n.exc 50mtr and funnel with watering pipe wire mesh GI protection pipe 40mm bore including testing complete including taking out old us earthing material all as specified and directed by Engineer-in-Charge. (Note - Earthing lead and GI protection pipe beyond 7.5 mtr shall be measured and paid deparately)
8
-
-
Supply, fixing and testing dry type 11 KV/ 3/110V/ 3 potential transformer (PT) suitable for 11 KV , 3 phase , 50 Hz , class 1A, 50 VA complete suitable for VCB 11 KV including taking out old unserviceable PT any type
2
-
-
Supply and fixing Dew guard is a passive solution for mitigation of condensation of tempreture between -30 deg C + 90 deg C, it is halogen free and silicon free, environment friendly and can be disposed of in regular trash of size 150 x 250 x 2 mm including fixign arrangement with strong addishve double sided tap all as spd and directed by engrs in charge. Cat Part No HDG X 150 Make Dew Guard of Hansal
15
-
-
Power pack of suitable capacity contained maintenance free battery and charger to provide auxilary power supply to the VCB all as per OEM recommendation or directed by EIC.
1
-
-
Excavation in trenches in any type of hard/dense soil n exc 1.5 mtr in width and n. exc 1.5 mtr in depth and getting out all as required for laying of cables,Foundation filling of poles or stays.
18.9
-
-
Returning filling, in including spreading ,leveling, watering and well ramming in layers not exc 25 cm each all as required.
11.34
-
-
Removing excavated material to a distance not exceeding 50 meters and depositing where directed at a level not exc 1.5 mtr above the starting point.
7.56
-
-
M & L for good quality dry sand cushioning to under ground electric cable and under the cable for protection , cable on layer of 8 cm thick before laying the cable and second layer of 15 cm thick after laying the cable all as specified and directed by Engr-in-Charge. Note : Sand shall be fined sand as specifed and punned thickness shall be measured and paid.
1.53
-
-
Supply and laying un-reinforced precast conrete cable cover suitable for 11000 volts grade HT UG cable laid the length of cover prependicular to the direction of cable of class HV type 1 flat size 300 mm x 180 mm x 40 mm all as directed.
389
-
-
Supply and laying connecting and testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured heavy duty electric power cable with aluminium conductor 11000V grade cross sectional area 95 Sq mm 3 core complete all as specified and directed.
80
-
-
M&L GI pipe light grade with all fitting laid in trenches and under road/floor/culverts along with pole etc 80mm bore.
20
-
-
M & L for cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable size 95 sqmm
6
-
-
Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable size 95 sqmm
5
-
-
M&L for checking and finding pin point location of fault in HT 11 KV UG cable of any size with the help of fault locating mobile machine complete all as directed.
Note : (i) Rate for rent of the fault locating mobile machine, charges for operator, engineer, electricians etc are deemed to be included in the quoted rate.
(ii) Fault should be located and repaired within 12 hours
3
-
-
Material & labour for Stay assembly complete with accessories such as MS stay plate of size 300mmx300mmx6mm thick, stay rod 20mm dia, stay bow, nuts, bolts and check nuts of GI including GI stay strand of size 7/4 mm all as shown in electrical plate No. 1 of SSR Part-I of 2009 or directed by Engr-in-charge.
Note: Earth work ( Excavation, Returning & refilling and removal), PCC, stay clamp and loop type insulators will be measured and paid separately under relevant schedule items).
10
-
-
M&L for Loop type insulator large size with overall dimensions 90x140mm with clearance of hole 25.5 mm vitreous white brown or green complete all as specified.
10
-
-
Supplying and laying synthetic Rubber insulated mats of size 2m x 1m x 2.5 mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety all as specified and directed .
8
-
-
Plain cement concrete (1:4:8) type D-2 (Using 40 mm graded crushed stone aggregate) as in foundation for poles mass concretes or in any indicated positions etc complete all as specified
1
-
-
Plain cement concrete (1:3:6) type C-2 (Using 40 mm graded stone aggregate) as in foundation filling and mass concrete for stay complete all as specified
0.5
-
-
Plain cement concrete (1:2:4) type B-2 (Using 20 mm graded stone aggregate) for coping of pole complete all as specified
2
-
-
Supplying and laying synthetic insulating mat of size 2Mtr x 1 Mtr x 19 mm class B, dielectric strength 45KV, complete all as specified and directed
8
-
-
M&L for sprading of agreegate for loose filling of hard core broken to gauge n exc 63mm graded complete all as specified and directed.
4
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%