Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.
Costs
EMD
₹ 24,000Document Cost
₹ 500Tender Fee
Refer Documents
Summary
Repair Replacement And Maintenance Of E/m Installations Sub Stations, Lt Panel Boards And Other Allied Works At Ins Chilka Under Ge Chilka
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_700025_1Tender No
GE/CHL/8116 OF 2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
General condition schedule of credit Special condition and Particular Specification
BOQ Items
... More
Supply and fixing in replacement 160 Amp MCCB 4pole, 36 Ka Cat Part No: TAB250NX160AC4P of HPL breaking capacity Adjustable type complete all as specified and directed by Engr-in-Charge. or Equivalent Make: Havells/ABB/Hager/Schneider
2
-
-
... More
Supply and fixing in replacement 125 Amp MCCB 4pole, 25 kA Cat Part No:TAB250CX125AC4P of HPL breaking capacity Adjustable Type complete all as specified and directed by Engr-in-Charge. or Equivalent Make: Havells/ABB/Hager/Schneider
2
-
-
... More
Supply and fixing in replacement 100 Amp MCCB 4pole, 16 kA Cat Part No: TAB160DX100AC4P of HPL breaking capacity Adjustabletype complete all as specified and directed by Engr-in-Charge.or Equivalent Make: Havells/ABB/Hager/Schneider
1
-
-
... More
Supply and fixing in replacement 63 Amp MCCB 4pole, 16 kA Cat Part No: TAB160DX063AC4P of HPL breaking capacity Adjustable type complete all as specified and directed by Engr-in-Charge. or Equivalent Make: Havells/ABB/Hager/Schneider
1
-
-
... More
M&L for Cement Concrete 1:4:8 B-2 Type(40mm graded aggregate) as in Foundation of Poles, Stays, etc. including Formwork (as required) and including demolition of existing concrete and removal debrises from site etc all complete all as specified and as directed.
1.5
-
-
... More
M&L for pre-cast RCC 1 : 2 : 4, type B-1 using 20 mm graded stone aggregate as in cover slabs for man holes/cable trench cover slab ,septic tank etc, set in cement mortar I : 4 and including demolition of existing concrete and removal debrises from site etc allcomplete all as specified and as directed.
2.3
-
-
... More
S&F TMT bars 10 mm dia and over , cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and as directed.
180
-
-
... More
S & F in repairs Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work for portion framed and hung as gates, including pintle hinges , atops hand made sliding bolt etc conforming to Fe.290.Gde-E-165
340
-
-
... More
S & F in repair MS screw bolts of dia 5-10 mm/Anchor Fastner ( machine made ) with hexagonal or square at one end and screwded with other end or screwed both ends length of bolt n exc 5cm long complete all as directed by engineer in charge
10
-
-
... More
M & L for servicing of LT panels/Feeder piller box of any size by complete cleaning of panel and bus bar at chamber with CRC solution, and welding the door using arc welding and fixing of hinges/Locking Handles/latches and necessary nut, bolts, washers and made it completely functional for open/close and incl checking of incoming and out going cable connections, Re-fixing of existing Cables, ACBs & MCCBs, and repair to connected PCC foundation and frame works, rewiring of control and power wiring of LT panel/Feeder with suitable size of FRLS cable but not less than 1.5 sqmm, replaceing of various unserviciable ON/OFF switches, lugs/Gland/Base plate/indicating Lamp/CT Coil etc making the panel fully functional including numbering the LT panel/feeder box and marking on panels (incoming and locations of outgoing MCCBs), to the satisfaction of Engr-in-Charge complete all as specified and as directed. Note : Cost is inclusiveof Minor parts such as lugs, gland, nuts, bolts, washers, locking handle, latches, ON/OFF switches, Base Plate but Excluding Ammeter, Voltmeter, CT Coil, Indicating Lamp.
16
-
-
... More
M&L for painting of LT panel by spraying two coats of Synthetic enammled paint of ivory colour over a coat of red oxide primer after cleaning of rusty panel surface of both inside/ outside by emery paper and necesary preparation of old steel surface complete all as specified and as directed.
50
-
-
... More
M & L for Earthing complete with galvanized earth plate electrode 600 x 600 x 6 mm buried directly in ground vertically to a depth of not less than 2.25 mtr below ground level connected to galvanised iron strip 32x6mm dia means of nut, bolts and washers made out of galvanized iron mild steel and 40 mm dia GI pipe "light grade" for protection of earth lead/Strip and connected to control board or main switch or as directed by Engineer -in-Charge including earthing pit in PCC (1:3:6) type C1 for chamber & Pre-cast RCC cover of size 380 x 380 x 40 mm with one handle made out of 8 mm dia round bar, 20 mm dia GI pipe light grade for watering funnels , wire mesh and provided charcoal or coke of alternative layers of 15 cm including necessary earth work complete.
5
-
-
... More
Material and labour for fixing XLPE round sheathed , stranded copper conductor cable, 1100 volts grade, cross-sectional area 2 core 6 sq mm , including taking down old UNSV cable complete all as directed.
100
-
-
... More
S&F in repairs aluminium lugs suitable for LT UG XLPE aluminium/copper conductor cable including nuts,bolts,washers and PVC tape. complete all as specified and as direcred for following sizes.
(a) 25 Sqmm LT UG XLPE aluminium/copper conductor cable
12
-
-
... More
(b) 16 sqmm LT UG XLPE aluminium/copper conductor cable.
16
-
-
... More
(c) 10 sqmm LT UG XLPE aluminium/copper conductor cable.
16
-
-
... More
(d) 06 sqmm LT UG XLPE aluminium/copper conductor cable.
20
-
-
... More
supply only Labour and highskilled electrician for findout of LT cable faults by disconnecting and taking out old existing LT cable of any sizes, in any position from trench/duct/panel and removing/excavating the outer surface of cable, examining cable and joints for defects and ascertaining suitability of cable for reuse, cutting out the defective portion of cable/joint, including taking out old serviceble PCC cable covers/Bricks or GI pipe of any type/size and relaying the cable with old serviceable bricks/PCC cable covers after repair/replacement of cable / jointing kit of any make or size of existing then make good the excavated area by returning/filling the same complete all as specified & directed. Note: (a) Using of new GI pipe or new jointing kit will be paid separately in concerned items (b) Excavation, refilling and sand/cable covers as used will be paid separately. (c) Irrespective of nature of complaint fault identification and necessary minor accessories as tape/lugs/nuts bolts/testing through test lamp or meggering for any fault identification and securing cables or connected switch gear after defect rectification is deemed to be included in the scope. (d) Fault finding Machine will be supplied by department but necessary tools /safety eqpts like hand gloves/discharge tools/helmet/torch/gum boots and other safety equipments as per standard practice is to be deemed to be included and proovided by contractor.
15
-
-
... More
Supply and fix in replacement of self powered relay having contact rating 5 amps, 220v AC,with Over current , Short circuit , Earth fault protection for Ring main unit system. Relay should have a front USB port for laptop interface, LCD display,10 event records, 5 fault records, min 2 setting group and keypad for setting parameters for the relay all as directed by engineer in charge. Cat NO: CSDPR-V2-200 of C&S Electric/L&T/Legrand/Siemens Note: after installation relay setting, calibration & test must be done by authorised OEM and testing report shall be submitted by contractor before processing payment .
5
-
-
... More
Supply and fix in replacement of power battery bank sealed Valve regulated lead acid(VRLA) battery nominal voltage 2V/cell , Ah capacity-200 Ah, cell type : 2V-200 Ah capacity with stand suitable for standby backup/ DC supply to 09 nos VCBs Pannel digital metering unit of main receiving system . Model no:IP9021 of Amara Raja or equivalent Amaron Quanta/Exide/Luminious Note:Battery Warrenty minimum 2 year and Warrenty card must be handed over to AGE E/M office by contractor bofore payment claim.
56
-
-
... More
Supply and fix in replacement of relay battery compact size high energy efficient sealed lithium cell battery 3 v, 2500mAh capacity for RMU Relay. Make: Duracell/Panasonic/Eveready/Maxwell
10
-
-
... More
Supply & fixing testing and commissioning in replacement CPRI approved vermin/weather proof LT panel board canopy outdoor type type factory made duly finished, double door, cubical type floor mounted of suitable size , Made out minimum 2.0 mm thick CRCA sheet powder coated mounted on angle iron frame (50mmx50mmx6 mm thick) from structure , three phase 440 volts with suitable high conductivity epoxy painted aluminium bus bars of 800 Amps rating - 04 Nos. mounted on porcelain insulators, drill for out going connection, prewired using suitable size of copper wire, using proper lugs / thimbles including din rail for fixing of MCCBs/MCBs, cable glands of suitable sizes for incoming and outgoing cables , including necessary locking arrangement complete all as specified and directed including the necessary PCC work and with and including following :- Note: (i) Contractor will submit drawing for approval, (ii) Cost included dismanteling of old unserviceable panle/busbar chamber including necessary terminmation/jointing in the replaced panel in complete):- Main Incoming : MCCB 400 Amp, microprocessor type 36 KA, 4 Pole - 01 No(Incomer)
Main Outgoing: (a) MCCB 250 Amp, microprocessor type 36 KA, 4 Pole - 1 Nos (b) MCCB 125 Amp, adjustable 25 KA, 4 Pole - 03 Nos (c) MCCB 200 Amp, adjustable 36 KA, 4 Pole - 01 Nos (Spare) (e) Digital Ammeter with CTs & Selector switches (f) Digital Voltmeter & Multifunction meter (g) RYB phase indicator.
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%