Military Engineer Services Tender

... More
Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date28 Dec 2024
Closing Date25 Jan 2025
Tender Amount₹ 15,00,000 
Notes
Download

Costs

Summary

Certain Repair Replacement And Maintenance Of Internal Point Wiring And Industrial Socket Wall Mounted Fans Highbay Medium Bay Light At Rx Em Installation Officers Mess Jo Mess Airfield Area Shankarpur And Pps At Arc Charbatia

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Ditto as item No.2 hereinbefore but for One 3 pin socket outlet 5/6 Amps, on the independent board.

10

-

-

... More
Ditto as item No.2 hereinbefore but for One 3 pin socket outlet 5/6 Amps, on the same board with other switches

10

-

-

... More
All as per item No.2 hereinbefore but with 2.5 sqmm PVC insulated (FR-LSH) unsheathed copper cable multistranded conductor 1100 volts grade for one 3 pin 16 Amps socket out let controlled by one switch on independent board.

5

-

-

... More
Material and labour for point wiring for light point or fan point with 1.5 sqmm PVC insulated (FR-LSH) unsheathed copper cable multistranded conductor 1100 volts grade IS694-1990 controlled by one way switch including 1.5 sqmm PVC (FR-LSH) insulated unsheathed copper cable multistrand conductor 1100 volts grade for continuity earth wire connected to common earth dolly drawn through existing PVC/metallic conceal conduit complete and making good the disturbed surafce all as specified and as directed.(Note:- Sufficient electrician /helper and other required items are to be provided immediately for repair/replacement as and when intimated).

30

-

-

... More
Ditto as item No.7 hereinbefore but for bell point controlled by one bell push switch.

5

-

-

... More
Ditto as item No.7 hereinbefore but for One 3 pin socket outlet 5/6 Amps, on the independent board.

10

-

-

... More
Ditto as item No.7 hereinbefore but for One 3 pin socket outlet 5/6 Amps, on the same board with other switches

10

-

-

... More
All as per item No.7 above but with 2.5 sqmm PVC insulated (FR-LSH) unsheathed copper cable multistranded conductor 1100 volts grade for one 3 pin 15/16 Amps socket out let controlled by one switch on independent board.

5

-

-

... More
Material and labour for point wiring for light point or fan point with 1.5 sqmm PVC insulated (FR-LSH) unsheathed copper cable multistranded conductor 1100 volts grade IS 694-1990 controlled by one way switch including 1.5 sqmm PVC (FR-LSH) insulated unsheathed copper cable multistrand conductor 1100 volts grade for continuity earth wire connected to common earth dolly drawn through and including PVC casing capping medium grade of size 20mm with all accessories on wll/floor/ceiling etc with 16G MS pressed steel terminal box with 3mm thick laminated sheet cover for mounting of fittings like switch, socket and fan regulator and making good the disturbed surafce complete all as specified and directed.

15

-

-

... More
Ditto as item No.12 hereinbefore but for One 3 pin socket outlet 5/6 Amps, on the independent board.

8

-

-

... More
Ditto as item No.12 hereinbefore but for One 3 pin socket outlet 5/6 Amps, on the same board with other switches

8

-

-

... More
All as per item No.12 hereinbefore but with 2.5 sqmm PVC insulated (FR-LSH) unsheathed copper cable multistranded conductor 1100 volts grade for one 3 pin 6/16 Amps socket out let controlled by one switch on independent board.

4

-

-

... More
S & F switch piano, flush type, single pole one way 5/6 Amp complete all as specified and directed.

131

-

-

... More
S & F socket outlet 3 Pin, 6 Amp flush type complete all as specified and directed.

56

-

-

... More
S & F switch piano 16 Amp flush type complete all as specified and directed.

14

-

-

... More
S & F socket outlet 16 Amp flush type complete all as specified and directed.

14

-

-

... More
S & F stepped type electronic fan regulator flush type for ceiling fan on the phenolic laminated sheet complete all as specified and as directed.

16

-

-

... More
M & L for ceiling rose PVC/Polycarbonate, isolated body 63.5 x 23.5mm 3 terminals complete all as specified and directed.

55

-

-

... More
S & F bell push flush type, 5/6 Amp complete all as specified and directed.

10

-

-

... More
S & F buzzer ding dong AC 230 Volts single pole complete all as specified and directed.

10

-

-

... More
S & F lamp holder PVC polycarbonate complete all as specified and directed.

20

-

-

... More
Supply and fixing in replacement LED tube light fittings 1 x 20 watts, 230 volts, 4 feet long complete with all accessories internally pre-wired and including connecting up with twisted flexible cable of 0.75 sq mm 3 core copper conductor from ceiling rose to light fittings complete including taking down old UNSV light fitting complete all as specified and directed. Make:-Havells/Crompton/Bajaj/ Philips

60

-

-

... More
S & F 15 Watt LED lamp complete all as specified and directed.Make:- Crompton/havells/bajaj/ syska/ phillips

60

-

-

... More
Supply and fixing sheet metal enclosure DB SPN 240 volts 8 way double door type with suitable rated bus bar for fixing MCB, including taking down old UNSV DB complete all as specified and directed. Make-Indoasian /Havells/Legrand/C&S

1

-

-

... More
Supply and fixing sheet metal enclosure DB SPN 240 volts 6 way double door type with suitable rated bus bar for fixing MCB including taking down old UNSV DB complete all as specified and directed. Make-Indoasian /Havells/Legrand/C&S

8

-

-

... More
Supply and fixing sheet metal enclosure DB SPN 240 volts 4 way single door type with suitable rated bus bar for fixing MCB including taking down old UNSV DB complete all as specified and directed.Make-Indoasian /Havells/Legrand/C&S

4

-

-

... More
Supply and fixing sheet metal enclosure DB SPN 240 volts 2 way single door type with suitable rated bus bar for fixing MCB including taking down old UNSV DB complete all as specified and directed.Make-Indoasian /Havells/Legrand/C&S

3

-

-

... More
Supply and fixing MCB SPN 240 volts 6 to 32 Amps, 10 kA, 'C' curve complete all as specified and directed. Make Indoasian /Havells/Legrand/C&S

16

-

-

... More
Supply and fixing MCB SP 240 volts 6 to 32 Amps, 10 kA, 'C' curve complete all as specified and directed. Make Indoasian /Havells/Legrand/C&S

46

-

-

... More
Supply and fixing sheet metal enclosure with single pole and neutral enclosure with at two pin and earth plug and socket with one single pole MCB 20 Amp, 10 kA, 'C' curve operated on 240 volt AC supply complete all as specified and directed. Make Indoasian /Havells/Legrand/C&S

4

-

-

... More
Material and labour for sub main wiring with two single core PVC insulated, PVC sheathed stranded copper conductor (FRLSH) cable of size 2 x 6 sq mm unsheathed drawn in and including PVC conduit and 1 x 6 sq mm PVC insulated unsheathed copper conductor as continous earth continuity conductor drawn in including taking down old UNSV submain wiring complete all as directed and specified. Note : Two runs of 6 Sqmm copper wire,one run of 6 Sqmm wire & one run PVC Conduit shall be measured as one unit.

100

-

-

... More
Material and labour for sub main wiring using two single core PVC insulated, PVC sheathed stranded copper conductor (FRLSH) cable of size 2 x 4 sq mm unsheathed drawn in and including PVC conduit and 1 x 4 sq mm PVC insulated unsheathed copper conductor as continous earth continuity conductor drawn in including taking down old UNSV submain wiring complete all as directed and specified. Note : Two runs of 4 Sqmm copper wire,one run of 4 Sqmm wire & one run PVC Conduit shall be measured as one unit.

100

-

-

... More
Material & Labour for earthing with galvanised steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel using GI or steel wire 4 mm dia as earthing lead as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20 mm graded stone aggregate, pit, funnel, 20 mm dia GI medium grade watering pipe, 15mm dia GI medium grade earth lead protection pipe and pre-cast earth pit cover made of RCC (1:1.5:3) type A1 duly reinforced with 8 mm dia TMT bar @150 c/c both ways, one lifting handle made out of 10 mm dia TMT bar 250 mm long embedded in cover slab and cover, wire, copper lugs etc mesh, charcoal and common salt in alternate layer of 15cm thick complete all as specified and directed.

7

-

-

... More
S&F Earth continuity conductor or main earthing lead fixed to wall or inside wall or batten or recess or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron wire and making good the disturbed surface complete all as specified and directed.

30

-

-

... More
M&L for services of jointing/taping or checking the electrical connections and securing after defect rectification in existing points/connection/items for light/call bell/ fan/regulators/capacitor/ sockets/ switches/ceiling rose/ switch socket boards/ junction boxes /metal/MCB sockets/power sockets or connected circuits till MCB controll in DB/earthing complete and refixing the existing items after defect rectification, as and when required complete all as specified and directed. Note: (i) Sufficient electrician /helper and other required items are to be provided immediately for repair as and when intimated (ii) The defect rectification of all connected items in the same circuits/ switch socket board will be counted as one job only (iii) Necessary tapping jointing lugging, minor connecting wires and securing and other minor items to make good the defects is deemed to be included.

50

-

-

... More
S & F in replacement to old unserviceable switch piano 15/16 Amp flush type complete all as specified and directed. Note: Necessary tapping jointing lugging, minor connecting wires and securing and other minor items is deemed to be included.

10

-

-

... More
S & F in replacement to old unserviceable socket outlet 15/16 Amp flush type complete all as specified and directed. (Note: Necessary tapping jointing lugging, minor connecting wires and securing and other minor items is deemed to be included.

10

-

-

... More
S & F in replacement to old unserviceable stepped type electronic fan regulator flush type for ceiling fan on the existing phenolic laminated sheet etc complete all as specified and directed. (Note: Necessary tapping jointing lugging, minor connecting wires and securing and other minor items is deemed to be included.

10

-

-

... More
S & F in replacement to old unserviceable bell push flush type, 5/6 Amp complete all as specified and directed. (Note: Necessary tapping jointing lugging, minor connecting wires and securing and other minor items is deemed to be included.

10

-

-

... More
S & F in replacement to old unserviceable buzzer ding dong AC 230 Volts single pole complete all as specified and directed. (Note: Necessary tapping jointing lugging, minor connecting wires and securing and other minor items is deemed to be included.

2

-

-

... More
S & F in replacement to old unserviceable switch piano, flush type, single pole one way 5/6 Amp complete all as specified and directed. (Note: Necessary tapping jointing lugging, minor connecting wires and securing and other minor items is deemed to be included.

50

-

-

... More
S & F in replacement to old unserviceable socket outlet 5/6 Amp flush type complete all as specified and directed. (Note: Necessary tapping jointing lugging, minor connecting wires and securing and other minor items is deemed to be included.

30

-

-

... More
S & F in replacement to old unserviceable ceiling rose PVC/Polycarbonate, isolated body 63.5 x 23.5mm 3 terminals complete all as specified and directed.

10

-

-

... More
Supply and fixing in replacement to old unserviceable MCB SPN 240 volts 63 Amps, 10 kA, 'C' curve complete all as specified and directed. Make Indoasian/Havells Standard/Legrand. (Note: Necessary tapping jointing lugging, minor connecting wires and securing and other minor items is deemed to be included).

4

-

-

... More
Supply and fixing in replacement to old unserviceableMCB SPN 240 volts 6 to 32 Amps, 10 kA, 'C' curve complete all as specified and directed. Make Indoasian/Havells Standard/Legrand. (Note: Necessary tapping jointing lugging, minor connecting wires and securing and other minor items is deemed to be included).

8

-

-

... More
Supply and fixing in replacement to old unserviceable MCB SP 240 volts 6 to 32 Amps, 10 kA, 'C' curve complete all as specified and directed. Make Indoasian/Havells Standard/Legrand. (Note: Necessary tapping jointing lugging, minor connecting wires and securing and other minor items is deemed to be included).

20

-

-

... More
Supply and fixing MCB TPN 415 volts 63-100 Amps, 10 kA, 'B' curve complete all as specified and directed. Make- Make Indoasian/Havells Standard/Legrand.

2

-

-

... More
Supplying and fixing in replacement 1100 volts grade 6 sqmm heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular complete all as specified and directed.

100

-

-

... More
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor of size 10 sq. mm nominal cross section, 2 core in service connections including taking down old UNSV service cable complete all as specified and directed.

100

-

-

... More
Supply and fix in replacement of heavy duty pedestal fan at Air field hanger of 450mm sweep metal blades, AC 230V 50 Hz complete with supply cables and plug top. (Note: - Old userviceable fans to be deposited to ARC as the items are belong to ARC property and not to be creadited to contractor)

20

-

-

... More
Supply and fix in replacement of heavy duty wall fan at Air field hanger of 450mm sweep metal blades, AC 230V 50 Hz complete with supply cables and plug top complete with installation on wall with necessary arrangements complete all as specified and directed. (Note: - Old userviceable fans to be deposited to ARC as the items are belong to ARC property and not to be creadited to contractor)

20

-

-

... More
S & F in replacement pure sine wave 1000 VA inverter with input 12V DC and output 230V AC, 50 Hz complete all as specified and directed. (Note: - Old userviceable inverter to be deposited to ARC as the items are belong to ARC property and not to be creadited to contractor)

2

-

-

... More
S & F in replacement 12 V,200 AH Lead-Acid battery complete all as specified and directed. Make: - Exide invatubular /Luminous (Note: - Old userviceable battery to be deposited to ARC as the items are belong to ARC property and not to be creadited to contractor)

2

-

-

... More
Supply and fixing in replacement Triple pole and earth encolsure with a three pin and earth plug with socket complete with one triple pole 32 Amps MCB complete all as specified and directed.Make- Havells /C &S/Legrand/L&T

6

-

-

... More
Supply and fixing in replacement Triple pole and earth encolsure with a three pin and earth plug with socket complete with one triple pole 63 Amps MCB complete all as specified and directed. Make- Havells /C &S/Legrand/L&T

4

-

-

... More
S&F in replacement MCCB 63 Amps with enclosure, 4 pole, 16 KA breaking capacity fixed thermal and fixed magnetic setting fixed in existing panel and connected to old existing cable including necessary fixing arrangement lugs, gland etc complete all as specified and directed. Make - Havells /C &S/Legrand/L&T

2

-

-

... More
S&F in replacement MCCB 100 Amps with enclosure, 4 pole, 25 KA breaking capacity fixed thermal and fixed magnetic setting fixed in existing panel and connected to old existing cable including necessary fixing arrangement lugs, gland etc complete all as specified and directed. Make- Havells /C &S/Legrand/L&T

2

-

-

... More
S&F 200 W LED highbay light fitting energy efficient light distribution with IP66 protection including all necessary clamps, nuts , bolts or fixing arrangement including taking down old UNSV complete all as specified and directed. (Make:Crompton/Havells/C&S)

22

-

-

... More
S&F in replacement 32 Amps 415 Volts Single Pole & Neutral Switch fuse unit complete all as specified and directed. Make:- Havells/L&T/Legrand/C&S/HPL

10

-

-

... More
S&F 63 Amps 4 way bus bar chamber with necessary fixing arrangement such as jointing material, nuts, bolts, washers and clamps etc complete all as specified and directed.

3

-

-

... More
S&F 100 Amps 4 way bus bar chamber with necessary fixing arrangement such as jointing material, nuts, bolts, washers and clamps etc complete all as specified and directed.

3

-

-

... More
S&F, PVC insulated 4 core 2.5 Sq mm stranded copper conductor cable for connecting junction box to street light fitting, testing and commissioning complete all as specified and directed. Make: Plaza/ Gloster/Polycab/Havells.

200

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.