Military Engineer Services Tender
Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.
Costs
EMD
₹ 90,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_682146_1Tender No
8995/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
M & L for repairing to rusted out sheet of outdoor unit for package type AC by necessary patching work with 2 mm thick steel sheet with welding/ brazing as per site requirement to make complete working condition complete all as specified and directed.
16
-
-
Servicing of electric control panel/compressure control pannel board of package AC 5 TR to 17.5 TR, by replacing burnt wire as exisiting at site with new of same specification alongwith new base to hold relays, and any other fixtures which is deemed to fix in the control panel for its proper operation of AC system, with clipping and socketing and dressing properly complete including replacement of the unserviceable spares.
7
-
-
S&F in repair electronic timer 3-30 sec ,5 A,24 volt AC complete all as specified and directed.
10
-
-
S&F in repair power contactor model no. ML 3 for AC circuit with AC Coils voltage 220 Volt over load relay 10-25 Amps and 2NO+2NC front mounted block.
14
-
-
S&F in repair power contactor model no. ML 1.5 for AC circuit with AC Coils voltage 220 Volt over load relay 10-25 Amps and 2NO+2NC front mounted block.
10
-
-
S&F in repair of single phase preventer 230V AC complete all as specified and directed
10
-
-
S&F in repair power contactor model no. MNX-12 4 pole 10 Amps for AC circuit with AC Coils voltage 220 Volt.
16
-
-
Labour to Attaining breakdown of package AC plants of 5.5/8.75/11.0/16.5/26 TR capacity and repair to breakdown and all parts and items of control panels , PCB, and accessories to keeping in perfect working condition all as specified and directed.
17
-
-
S&F in repair/ replacement of unsv three phase Control PCB for package type AC plant of 5.5 TR Capacity and repair to breakdown comprising of all (suitable for Bluestsar/Voltas Make) all as specified and directed.
4
-
-
S&F in repair/ replacement of unsv three phase Control PCB for package type AC plant of 17 TR Capacity and repair to breakdown comprising of all (suitable for Bluestsar/Voltas Make) all as specified and directed.
3
-
-
S&F in repair three phase Control PCB for package type AC plant of 8.75 TR Capacity and repair to breakdown comprising of all (suitable for Bluestsar/Voltas Make) , all as specified and directed.
10
-
-
S&F in repair three phase Control PCB for package type AC plant of 11 TR Capacity and repair to breakdown comprising of all (suitable for Bluestsar/Voltas Make) , all as specified and directed.
2
-
-
S&F in repair three phase Control PCB for package type AC plant of 10 TR Capacity and repair to breakdown comprising of all (suitable for Bluestsar/Voltas Make) , all as specified and directed.
4
-
-
S&F in repair to terminal/ connector of any size available at site complete all as specified and directed.
45
-
-
S&F in repair fan capacitor of 10±2% mfd capacity suitable for out door unit of package type AC plant of 5.5/8.75/11/16.5 TR Capacity, (suitable for Blue Star/Carrier/Voltas Make) , all as specified and directed.
27
-
-
Supply and fixing in repair MCB TPN 63 Amps 450 V for connection of package/central type AC plant.
9
-
-
Supply and fixing in repair MCB TP 32 Amps 450 V for connection of package/central type AC plant.
9
-
-
S & F in repair Electronic overload motor protection relay range between 9-45 Amps
6
-
-
M/L for carrying out spray painting complete unit of Package unit Indoor & Outdoor of any make, model and capacity after dismantling, and painting on sheet metal enclosers internally and externally with two coats of synthetic enamel paint of approved make and shade after preparation of surface, re-assembling and reconnecting the AC unit at its installed location complete all as directed.
20
-
-
S&F in repair PVC Drain pipe of size 40 mm size suitable for package type AC of any capacity including provision of requisite PVC fasteners.
40
-
-
S&F in replacement of 25 mm thick closed cell Nitrile rubber sheet by applying of suitable adhesive as applicable to less then 4 degree temperature including takingdown old one complete all as specified and as directed.
7
-
-
Supply and fixing, V belt of suitable sizes for 5.5TR capacity Package type AC plant blower motor. Make : FENNER/Dunlop
8
-
-
Supply and fixing for V belt of suitable sizes for 8.75 TR capacity Package type AC plant blower motor; Make : FENNER/Dunlop
9
-
-
Supply and fixing for V belt of suitable sizes for 11.0 TR capacity Package type AC plant blower motor ; Make : FENNER/Dunlop
3
-
-
Supply and fixing for V belt of suitable sizes for 10.0 /17 TR TR capacity Package type AC plant blower motor ; Make : FENNER/Dunlop
3
-
-
Supply and fixing for V belt of suitable sizes for 16.5/26 TR capacity Package type AC plant blower motor ; Make : FENNER/Dunlop
2
-
-
Supply and fixing in repair/replacement of ball bearing for 5.5/8.75/11/16.5/26 TR package AC blower shaft bearing all as specified as required
7
-
-
M &L for Carrying out cleaning and de-scaling of iron deposited in shell and tube type condenser by using chemical suitable for Descalling for the condensor unit of the compressor with the help of monoblock pump set , recommended by manufacturer manual of the respective plant by using complete with satisfactory for Capacity 3x75 TR central type AC Plant all specified and directed by Engr - in charge. Note:- Descaling of all three condensor units done in this job.
1
-
-
M &L for Carrying out cleaning and de-scaling of iron deposited in shell and tube type condenser by using chemical suitable for Descalling for the condensor unit of the compressor with the help of monoblock pump set , recommended by manufacturer manual of the respective plant by using complete with satisfactory for Capacity 3x 85 TR central type AC Plant all specified and directed by Engr - in charge. Note:- Descaling of all three condensor units done in this job.
1
-
-
All as per Sl Item No. 31 here -in-before but compressor of capacity 3x 40 TR at Auditorium Bldg
(Make : VOLTAS or equivalent as approved)
Note:- Descaling of all three condensor units done in this job.
1
-
-
Supply only for Recharge/Top up Refrigerant R-22 in central type AC plant of various capacities complete all as specified and directed. Make : Mafron/Floron/Refron.
260
-
-
Labour for pressure testing / leak arresting , vaccumising with dry nitrogen gas / oil charging, incl replacing the unserviceable strainers all as required and testing complete for Central type Air Conditioning Plant of capacity existing at site.
Note :- Refrigerant Gas R-22/R- 410/413/407C and strainers will be measured and paid seperately under supply only items
3
-
-
Labour for pressure testing / leak arresting , vaccumising with dry nitrogen gas / oil charging, incl replacing the unserviceable strainers all as required and testing complete for central Air Conditioning Plant 40 TR to the 85 TR plants Note :- Refrigerant Gas R-22/R- 410/413/407C/R134a and strainers will be measured and paid seperately under supply only items
5
-
-
M & L for dismandling and repairing of pump set/ motor of capacity 7.5 HP for CHW/condenser punmp set and motor seperately cutting the burnt out wiring from slots and rewinding the ame by existing size and guage of super enamelled copper wire including varninshing ,heating,including replacing the gland packing, bearings and all rusted nut and bolts, washers and reassembling ,fixing the motor and pump at its position and connecting the suction and delivery water pipe and testing under working conditions complete all as directed .
10
-
-
All as per as above Sl Item No. 36 here-in-before but 10 HP capacity complete all as directed.
4
-
-
Supply Fabricate and fixing of MS angle/MS plate/flat/rod for cooling tower frame, CT fan base, cooling tower ladders, and all supports made out of suitable size along with welding/MS nuts, bolts and washers, hinges, locking arrangement including painting with two coats of synthetic enamel paint over one coat of red oxide primer including removimg existing unserviceable rusted one ,all as specified and directed by Engineer-in-Charge
490
-
-
S & F micro 'V' filter upto 10 micron 5 to 10 cm thick for AHU as per existing shape and size complete all as specified and as directed.
18.59
-
-
M & L for repair to damaged fiber of cooling tower by necessary cutting and patch work by casting with fiber material to match the existing complete all as specified and directed.
1.12
-
-
M & L for repairing of existing cooling tower by taking down all side FRP panel, spray nozzel, inside pipe network for spraying inside cooling tower,inlet pipe etc making leakproof ,necessary welding/fabrication work and reassembling the same complete all as specified and directed.
3
-
-
M & L for Supply , assembly and erection of outdoor Ducting by complete replacement of existing size and thickness of innner duct with GSS duct 120 GSM ( 20 SWG )rectangular/ Square boxed, incl all accessories such as MS Angles frame at ducts joints for support of ducts , corner, cleat, carriage bolt Gasket and appropriate sealant on longitudinal joints and Duct insulation against replacement of unsv duct of any size as per site with Nitrile rubber , 50 mm thick thermocol including other binding like CPRX for fixing/bonding of thermocol and hessian clothes as covering materials and finished with cement mortar / lath plaster with the help of wire mess of appropate size and finally painting two coat with suitable materials like snosam/distamper mixed with water resistance materials to match with existing surface complete all as specified and directed including taking down old unsv materials.
232
-
-
M&L for flushing of entirely MS chilled water flow network to removing sludges, algae, hard scale, forgein materials, from network of 3 x 85 TR central AC plant using suitaqble scraping brush to removable part of pipeline network and by suitable chemical using centrifugal pump to non removable section complete all as specified and directed.
1
-
-
All as per Item No. 43 above but for the capacity of 03 x 40 TR
1
-
-
M&L for flushing of entirely MS chilled water flow network to removing sludges, algae, hard scale, forgein materials, from network of 3 x 75 TR central AC plant using suitaqble scraping brush to removable part of pipeline network and by suitable chemical using centrifugal pump to non removable section complete all as specified and directed.
1
-
-
M & L for dismantling and taking out of cooling coil of AHU of 75 TR capacity and flushing out and cleaning to cooling coil tube and fins complete by using suitable chemical as per OEM recommendation to make it efficient and proper heat transfer and reassemble to AHU and testing complete all as specified and directed.
3
-
-
S & F repair oil seal ,O ring , carbon bushing of shaft of central type AC plant compressor of 75 TR capacity.
2
-
-
M & L for dismantling and taking out of cooling coil of AHU of 85 TR capacity and flushing out and cleaning to cooling coil tube and fins complete by using suitable chemical as per OEM recommendation to make it efficient and proper heat transfer and reassemble to AHU and testing complete all as specified and directed.
1
-
-
S & F repair oil seal ,O ring , carbon bushing of shaft of central type AC plant compressor of 85 TR capacity.
2
-
-
S&F MS pipe 100 mm dia heavy grade with all fittings laid in floors or fixed to walls and ceilings including taking down old MS pipe for Central AC Plant (Make : Tata steel/Jindal steel)
12
-
-
S&F UPVC pipe 150 mm dia with all fittings laid in floors or fixed to walls and ceilings including taking down old pipe for Central AC Plant
20
-
-
S&F in repair V-Belt A-34/A-37/A-38/A-52/A-54 includong taking down complete all as specified and directed.
8
-
-
All as per item no. above but here in before for AHU fan as per existing size B-71/B-79/B-84 V belt complete all as specified and directed.
6
-
-
Supply and fixing of PVC Fills as per existing size at site, blue/black colour, suitable for any type of cooling tower of central air conditioning plant
113
-
-
S&F in repair power contactor model no. MNX 25 for AC circuit with AC Coils voltage 220 Volt ,over load relay 25-45 Amps.
13
-
-
S&F in repair Safety valve 300 PSI of copper material suitable for 75 TR capacity Central/package type AC plant (as per existing make and model)
1
-
-
S&F in repair Safety valve 300 PSI of copper material suitable for 85 TR capacity Central/package type AC plant (as per existing make and model)
3
-
-
Supply and fixing GI tubing medium grade of 40 mm bore size with all fittings laid in trenches, floor, roof and wall and tank connection complete including cutting and thereading with all fittings like tee, elbow bend union reducer hex nipple etc and all as directed.
12
-
-
All as per as above Sl Item No 58 but bore size 25 mm
18
-
-
S&F in repairs gun metal gate valve of 40 mm bore size ISI marked with iron wheel head, screwed both ends for iron pipe including taking down the unserviceable existing ones
2
-
-
All as per as above Sl Item No 60 but bore size 25 mm
2
-
-
Supply and fix in repair PVC Ball valve 40mm bore (minimum wt 690 gms) ISI marked high presssure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed.
2
-
-
All as per Sl Item No. 62 above but 25mm bore (minimum wt 455 gms)
2
-
-
Supply & Fixing as in repair CI butterfly valve PN 1.6 size of dia150 mm , valve should fix at position including necessary connected work complete all as directed.
4
-
-
Supply and fixing in repair MCB SP 6-32 Amps, 10kA C curve for connection of package/central type AC plant.
16
-
-
S & F stainless steel Y strainer filter mesh including taking down old one for 150 mm dia strainer.
10
-
-
S& F in repair IVRF AC of 26 HP outdoor unit PCB fan card
1
-
-
S& F in repair IVRF AC of 26 HP Cassate AC master indoor unit PCB
1
-
-
S& F in repair IVRF AC of 26 HP outdoor unit Mother board PCB
1
-
-
M & L for replacement of old unsv expasion valve suitable for 85 TR central AC of Make Carrier including necessary work to make plant functional Complete all as specified and directed.
1
-
-
M&L for two coats of oil bound distemper over a coat of primer on plastered surfaces of walls of any description incl preparation of surfaces all as specified and as directed.
66
-
-
M & L for dismantling and taking out unserviceable and defective parts of compressor of chiller Units of Central type AC Plants of capacity 25 to 75 TR of any make,and model after disconnecting the discharge & suction line removal of necessary electrical connection etc. Dismantling compressor body complete and carry out the repair work as per the following :-
(a) Repairs to crank shaft, connecting rod, piston, piston pin valve plate by remetaling, cutting/grinding and polishing as required and by supply and replacing all spare parts with new one as required and directed.
(b) Repairs /fixing by replacing of all new discharge and suction reeds, big end and small end bush, all bearing, all piston rings, capillary drier cum filter with new one all as specified and directed .
(c) Repairs/fixing by replacing of all new kinds of gasket, washers, scappring made of Nylon/ Tuflon sheet/ rubber/fibre sheet as required with new one and all as directed.
(d) Repair of Oil pump kit by , dismantling and cleaning, greasing oiling along with new gasket all as required and directed.
(e) M & L for Repair/replacement of old u/s copper pipe line as per existing size and shape when found leaking/damage at the time of leak check including necessary flairing, brazing as required and replacement of end fittings made of copper including brass flange nuts, brass dead cap and brass pipe as per site requirement and as directed.( Note : - The cost of new Copper pipe is also included in the same job )
(f) Supply and fix in repair of all u/s rusted bolts, nuts and washers of any kind/made of any metalical/any size and shape as per site requirement with new one all specified and directed. (Note :- The cost of all types/sizes of new nuts , bolts and washers are included in the same job.
(g) After the repair work re-assembling the plant and check for leak in system with the help of Nitrogen gas. in case of any leak is detected the repair is to be carried out without any extra cost nitrogen/refrigerant gas. (h) After leak repair release Nitrogen and charge with refrigerant gas and testing to be carried out.
Note : The cost for Nitrogen gas for Leak test, Charging/top up of Compressor oil and refrigerant gas (R-22) and necessery spares will be measured & Paid separately against ser Items No-2 to 14 and ser items No-73 to 90 of this schedule.
1
-
-
Supply only Suction reed as per existing make and model .
4
-
-
Supply only Discharge reed as per existing make and model.
4
-
-
Supply only Main Bearing as per existing make and model
4
-
-
Supply only Thrust Bearing as per existing make and model
4
-
-
Supply 0nly Piston Pin as per existing make and model.
4
-
-
Supply only Piston as per existing make and model.
2
-
-
Supply only Piston Ring as per existing make and model
4
-
-
Supply only Discharge and Suction Ring as per existing make and model.
2
-
-
Supply only Gasket Set asper existing make and model
9
-
-
Supply only liquid line filter as per existing make and model .
4
-
-
Supply only internal suction filter as per existing make and model
4
-
-
Supply only by pass solenoid valve oil valve as per existing make and model.
2
-
-
Supply only Loading/unloading solenoid valve as per existing make and model
12
-
-
Supply and fix as in repair chiller/condensor water flow switch as per existing make and model
1
-
-
Supply and fix as in repair drier filter as per existing make and model
1
-
-
Supply and fix as in repair chiller/condensor water senser as per existing make and model
1
-
-
Supply and fix as in repair oil pump motor as per existing make and model
2
-
-
Supply and fix as in repair chiller pressure switch as per existing make and model
2
-
-
Supply and fix compressor oil heater 600W as per existing size for Central type AC plant of capacity upto 75 TR including taking down old unserviceable one all as specified and directed.
2
-
-
Supply and fix Water pressure gauge 8" up to 0-14 kg/cm.sq along with fittings to be fitted on water pipe line including taking down old unserviceable one all as specified and directed
11
-
-
S&F Rotational moulded polyethylene water storage tanks 1000 ltrs for chilled water makeup tank (cubical with closed top) hoisted and fixed in position all as per specified in SSR part -I
1
-
-
M&L for painting to complete chilled water type Central Air Conditioning plant of 75 TR capacity at Control Centre Bldg, including complete chiller unit, compressor, motor, condenser refrigerant pipe, water pipe, chilled water pipe line, AHU, cooling tower, LT panel board complete plant with two coat of synthetic enamelled paint including preparation of surfaces and as per colour code all as specified and directed by Engineer - in - charge .
3
-
-
M&L for one coat of synthetic enemel paiint over a coat of red oxide primer on steel surfaces over 10 cm width or grith complete including preparation of old surfaces of steel by scraping , rubbing all as specified and directed.
40
-
-
Servicing of electric control panel/compressure control pannel board of cenral AC 75 TR of existing make by replacing burnt wire as exisiting at site with new of same specification alongwith new base to hold relays, and any other fixtures which is deemed to fix in the control panel for its proper operation of AC system, with clipping and socketing and dressing properly complete including replacement of the unserviceable spares.
Note-U/S spares to be measured and paid seperately as supply only items under Item No. 97 to 101 of this schedule .
3
-
-
Supply only Relay holder 8 pin channel mounting type as per existing
10
-
-
Supplu only relay 8 pin type as per existing
10
-
-
Supply only timer switch
2
-
-
Supply only selector switch
1
-
-
Supply only denfoss make HP/LP cut out switch
1
-
-
S&F in replacement of overload switch of compressor motor for 75 TR Central AC plant
2
-
-
Supply and charging / top up of comressor oil in reciprocating type central AC plants, Type : HPL -68 or equivallent as per existing sample ( Make : SERVO/INDIAN OIL or equivallent as approved)
110
-
-
M&L for repairing of Chillar waterpipeline insulation 50 mm thick thermocol including other binding like CPRX for fixing/bonding of thermocol and plastic and hassain clothes as covering mterials and finished with cement mortar / lath plaster with the help of wire mess of appropate size and finally painting two coat with suitable materialslike samosan/distamper water resistance materials to match with existing surface complete all as specified and directed including taking down old unsv materials.
135
-
-
M&L for PVC tank insulation 50 mm thick thermocol including other binding like CPRX for fixing/bonding of thermocol and plastic and hassain clothes as covering mterials and finished with cement mortar / lath plaster with the help of wire mess of appropate size and finally painting two coat with suitable materialslike samosan/distamper including foundation for the PVC tank as per site complete all as specified and directed including taking down old unsv materials.
1
-
-
M & L for dismantling and taking out unserviceable and defective parts of compressor of chiller Units of Central type AC Plants of capacity 40 TR of any make,and model after disconnecting the discharge & suction line removal of necessary electrical connection etc. Dismantling compressor body complete and carry out the repair work as per the following :-
(a) Repairs to crank shaft, connecting rod, piston, piston pin valve plate by remetaling, cutting/grinding and polishing as required and by supply and replacing all spare parts with new one as required and directed.
(b) Repairs /fixing by replacing of all new discharge and suction reeds, big end and small end bush, all bearing, all piston rings, capillary drier cum filter with new one all as specified and directed .
(c) Repairs/fixing by replacing of all new kinds of gasket, washers, scappring made of Nylon/ Tuflon sheet/ rubber/fibre sheet as required with new one and all as directed.
(d) Repair of Oil pump kit by , dismantling and cleaning, greasing oiling along with new gasket all as required and directed.
(e) M & L for Repair/replacement of old u/s copper pipe line as per existing size and shape when found leaking/damage at the time of leak check including necessary flairing, brazing as required and replacement of end fittings made of copper including brass flange nuts, brass dead cap and brass pipe as per site requirement and as directed.( Note : - The cost of new Copper pipe is also included in the same job )
(f) Supply and fix in repair of all u/s rusted bolts, nuts and washers of any kind/made of any metalical/any size and shape as per site requirement with new one all specified and directed. (Note :- The cost of all types/sizes of new nuts , bolts and washers are included in the same job.
(g) After the repair work re-assembling the plant and check for leak in system with the help of Nitrogen gas. in case of any leak is detected the repair is to be carried out without any extra cost nitrogen/refrigerant gas. (h) After leak repair release Nitrogen and charge with refrigerant gas and testing to be carried out. Note : The cost for Nitrogen gas for Leak test, Charging/top up of Compressor oil and refrigerant gas R-22/(R-134a) and necessery spares will be measured & Paid separately
3
-
-
M & L for dismantling and taking out unserviceable and defective parts of compressor of chiller Units of Central type AC Plants of capacity 85 TR of any make,and model after disconnecting the discharge & suction line removal of necessary electrical connection etc. Dismantling compressor body complete and carry out the repair work as per the following :-
(a) Repairs to crank shaft, connecting rod, piston, piston pin valve plate by remetaling, cutting/grinding and polishing as required and by supply and replacing all spare parts with new one as required and directed.
(b) Repairs /fixing by replacing of all new discharge and suction reeds, big end and small end bush, all bearing, all piston rings, capillary drier cum filter with new one all as specified and directed .
(c) Repairs/fixing by replacing of all new kinds of gasket, washers, scappring made of Nylon/ Tuflon sheet/ rubber/fibre sheet as required with new one and all as directed.
(d) Repair of Oil pump kit by , dismantling and cleaning, greasing oiling along with new gasket all as required and directed.
(e) M & L for Repair/replacement of old u/s copper pipe line as per existing size and shape when found leaking/damage at the time of leak check including necessary flairing, brazing as required and replacement of end fittings made of copper including brass flange nuts, brass dead cap and brass pipe as per site requirement and as directed.( Note : - The cost of new Copper pipe is also included in the same job )
(f) Supply and fix in repair of all u/s rusted bolts, nuts and washers of any kind/made of any metalical/any size and shape as per site requirement with new one all specified and directed. (Note :- The cost of all types/sizes of new nuts , bolts and washers are included in the same job.
(g) After the repair work re-assembling the plant and check for leak in system with the help of Nitrogen gas. in case of any leak is detected the repair is to be carried out without any extra cost nitrogen/refrigerant gas. (h) After leak repair release Nitrogen and charge with refrigerant gas and testing to be carried out.
Note : The cost for Nitrogen gas for Leak test, Charging/top up of Compressor oil and refrigerant gas (R-22)/R-134a and necessery spares will be measured & Paid separately
3
-
-
Supply only Suction reed as per existing make and model .
12
-
-
Supply only Discharge reed as per existing make and model.
12
-
-
Supply only Main Bearing as per existing make and model
12
-
-
Supply only Thrust Bearing as per existing make and model
12
-
-
Supply 0nly Piston Pin as per existing make and model.
12
-
-
Supply only Piston as per existing make and model.
8
-
-
Supply only Piston Ring as per existing make and model
12
-
-
Supply only Discharge and Suction Ring as per existing make and model.
2
-
-
Supply only Gasket Set asper existing make and model
9
-
-
Supply only liquid line filter as per existing make and model .
4
-
-
Supply only internal suction filter as per existing make and model
4
-
-
Supply only by pass solenoid valve oil valve as per existing make and model.
9
-
-
Supply only Loading/unloading solenoid valve as per existing make and model
8
-
-
Supply and fix as in repair chiller/condensor water flow switch as per existing make and model
8
-
-
Supply and fix as in repair drier filter as per existing make and model
2
-
-
Supply and fix as in repair chiller/condensor water senser as per existing make and model
3
-
-
Supply and fix as in repair oil pump motor as per existing make and model
3
-
-
Supply and fix as in repair chiller pressure switch as per existing make and model
4
-
-
Supply and fix compressor oil heater 600W as per existing size for Central type AC plant of capacity 40 to 85 TR including taking down old unserviceable one all as specified and directed.
3
-
-
M&L for painting to complete chilled water type Central Air Conditioning plant of 85 TR capacity at Control Centre Bldg, including complete chiller unit, compressor, motor, condenser refrigerant pipe, water pipe, chilled water pipe line, AHU, cooling tower, LT panel board complete plant with two coat of synthetic enamelled paint including preparation of surfaces and as per colour code all as specified and directed.
3
-
-
All as per Sl Item No. 127 above but for 3X 40 TR Central AC Plant
3
-
-
Servicing of electric control panel/compressure control pannel board of cenral AC plant 40 TR to 85 TR of existing make by replacing burnt wire as exisiting at site with new of same specification alongwith new base to hold relays, and any other fixtures which is deemed to fix in the control panel for its proper operation of AC system, with clipping and socketing and dressing properly complete including replacement of the unserviceable spares.
Note-U/S spares to be measured and paid seperately as supply only items No. 130 to 134 under this schedule .
3
-
-
Supply only Relay holder 8 pin channel mounting type as per existing
10
-
-
Supplu only relay 8 pin type as per existing
10
-
-
Supply only timer switch
2
-
-
Supply only Catchall liquid line filter as per existing
1
-
-
Supply only denfoss make HP/LP cut out switch
1
-
-
S&F in replacement of overload switch of compressor motor for 85 TR Central AC plant
1
-
-
Supply and fixing compressor oil filter as per exisiting size complete all as specified and directed.
2
-
-
M&L for in replacement of Water strainer filter suitable for central AC plant of capcity 85 TR plant complete all as specified and directed.
2
-
-
M & L for replacement of U/S canvas cloth of package/central type AC planrs including provisiong of zip 150 mm lenth for opening and closing arrangements and properlly fasterners with bolts and nuts between the ducts all as directed.
3
-
-
M&L for repairing of AHU base frame by taking down exsisting parts and reassemble the same after providing required MS Angle/MS Cheqqured plate of 5 mm thick all supports made out of suitable size along with welding/MS nuts, bolts and washers, hinges, locking arrangement including painting with two coats of synthetic enamel paint over one coat of red oxide primer including removimg existing unserviceable rusted one and providing the insulation as per the exisisting and making all good as per eisisting to run the AHU uinit functional complete all as sirected.
3
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%