Military Engineer Services Tender

Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.

Military Engineer Services - MES Tender

Works
Eprocure
Opening Date23 Jan 2021
Closing Date12 Feb 2021
Tender Amount₹ 45,00,000 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L for TMT Bars 5 mm dia & over upto & including 10 mm dia in stirrups, spaces & binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.90mm dia or securing with clips. Complete all as specified & as directed.

131.88

-

-

... More
Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.

40

-

-

... More
M&L Brick work using fly ash bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed.

40

-

-

... More
Taking down cement plaster on brick or concrete surface including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.

200

-

-

... More
M&L for rendering 15mm thick in CM 1:6 on brick or concrete surface, finishing even and smooth without using extra cement complete all as specified and directed.

600

-

-

... More
M&L for preparation of new plastered or unplastered surfaces of walls and applying two coats of cement based paint complete all as specified and directed

300

-

-

... More
M&L for preparation of new plastered or unplastered surfaces of walls and applying three coats of white wash complete all as specified and directed

300

-

-

... More
M&L preparation of old painted surfaces of walls and applying one coat of cement based paint complete all as specified and directed.

2000

-

-

... More
M&L preparation of old painted surfaces of walls and applying one coat of white wash complete all as specified and directed.

1000

-

-

... More
Demolition of Cement Concrete (unreinforced) of any description & in any position not otherwise specifically provided for complete all as specified and directed.

76.15

-

-

... More
M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed.

17.4

-

-

... More
M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in surface channels and drains complete all as specified and directed.

3.75

-

-

... More
M&L Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc complete all as specified and directed.

150

-

-

... More
M&L for add or deduct for each 25mm girth or part thereof over or under 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc complete all as specified and directed.

75

-

-

... More
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth for foundation etc or for shafts, wells cesspits manholes pier holes etc not exceeding 10 Sqm on plan and not exceeding 1.5 m depth in soft /loose soil etc complete all as specified and directed

21

-

-

... More
Returning, filing in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in any type of soil etc complete all as specified and directed

10

-

-

... More
Removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.

11

-

-

... More
S&F reinforced concrete pipes, class NP-2, laid and jointed complete with collars of 300mm dia as in repair complete all as specified and directed.

15

-

-

... More
S&F reinforced concrete pipes, class NP-2, laid and jointed complete with collars of 450mm dia as in repair complete all as specified and directed.

15

-

-

... More
M&L for 50 mm High density polyethelyene pipes (HDPE) of pressure rating 6kgf/sqcm laid in trenches complete all as specified and directed.

20

-

-

... More
M&L for hard core of gauge n exc 63 mm, deposited, spread and levelled in layers n exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed.

30

-

-

... More
M&L for 100 mm thick cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as sub base of floor complete all as specified and directed.

200

-

-

... More
M&L for 50 mm thick cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate as in path/hard standing surface finished even and smooth without using extra cement complete all as specified and directed.

100

-

-

... More
M&L for forming construction joints 50 mm x 10 mm wide filled with sealing compound Grade A complete all as specified & directed.

5.5

-

-

... More
M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in lintels upto 1.5 m clear span, coping, benching, bed block, lintel band, plinth courses etc and similar work including weathering,slightly rounded or chamfered angles and throating including necessary form work complete all as specified and directed.

4.5

-

-

... More
M&L for complete removal of existing treatment on walls and applying two coats of cement based paint complete all as specified and directed

1000

-

-

... More
S&F 110mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed

20

-

-

... More
S&F 110mm bore PVC (SWR) bends any radius complete all as specified and as directed

5

-

-

... More
M&L for Demolition and breaking up drain pipe (salt glazed ware, AC or reinforced concrete ) set in cement mortor for 300 mm to 450 mm internal dia of pipe complete all as specified and directed.

30

-

-

... More
M&L for complete removal of existing treatment and preparation stone surface and applying two coats of colourless silicon water repellent of make Nitocote SN 522 or equivalent on stone walls complete all as specified and directed.

300

-

-

... More
M&L for preparation of old painted surfaces and applying one coat of synthetic enamel paint in concrete surface complete all as specified and directed.

300

-

-

... More
M&L preparation of old painted floor surfaces and applying one coat of floor coat apex floor guard of asian paint or equivalent paint complete all as specified and directed.

7212

-

-

... More
Supply, installing, testing and commissioning of out door type panel of size not less than 1000 x 1000 x 500 mm of factory made Polycarbonate (shock proof, rust free, corrosion free , acid and chemical resisitant, fire retardant having high impact, made of halogen and silica free recuclable material), UV resistant, having internally embedded high grade gasket made of Polyurethane, should withstandglow wire test at 960 C , should be flame retardent , the panel should hold test certificate (CPRI) with switchgear assemblies as per IEC 60 439-1 following testers performed and passed satisfctorily (a) Temp rise (b) Dielectric properties (3) Short Circuit withstand current - rated peak & short time withstand current and rated conditional short circuit current (4) Effectiveness of protective circuits (5) Clearence & creep age distance (6)Mechanical operation , complete with necessary faoundation work as directed by the Engr-in-Charge and making proper connections, terminals, thimbles etc incl the following components etc complete all as specified :- Bus Bar 04 Nos 600 Amps (03 Nos) and 400A (01 Nos), not less than 30 cm in a separate Bus Bar chamber Volt Meter, 96mm2 flush type rated 0-500 V Digital type with instrument fuses & Volt slectro swithc with interconnections -01 Set , alongwith Amp-Meter, 96mm2 flush type rated 300A, digital type CT Operated with 03 Nos CTs and Amp Selector switch complete with inter connections -06 Sets , both in separate instumental chamber .including one spare comprtment LED Indicating lamps R,Y,B-01 Set (a) MCCB 400 Amps , 4 Pole- 415 Volts /36 KA , 50Hz -01 No (I/C) (b)MCCB 250 Amps , 4 Pole 415 Volts/ 25 KA, 50Hz -06 Nos (O/G)

4

-

-

... More
All as per above item no 36 but of following specification (a) MCCB 250 Amps , 4 Pole- 415 Volts /25 KA , 50Hz -01 No (I/C) (b)MCCB 100 Amps , 4 Pole 415 Volts/ 16 KA, 50Hz -04 Nos (O/G)

4

-

-

... More
Supply, installing, testing and commissioning of out door type panel of size not less than 900 x 900 x 300 mm of factory made Polycarbonate (shock proof, rust free, corrosion free , acid and chemical resisitant, fire retardant having high impact, made of halogen and silica free recuclable material), UV resistant, having internally embedded high grade gasket made of Polyurethane, should withstandglow wire test at 960 C , should be flame retardent , the panel should hold test certificate (CPRI) with switchgear assemblies as per IEC 60 439-1 following testers performed and passed satisfctorily (a) Temp rise (b) Dielectric properties (3) Short Circuit withstand current - rated peak & short time withstand current and rated conditional short circuit current (4) Effectiveness of protective circuits (5) Clearence & creep age distance (6)Mechanical operation , complete with necessary faoundation work as directed by the Engr-in-Charge and making proper connections, terminals, thimbles etc incl the following components etc complete all as specified :- Bus Bar 04 Nos 250 Amps (03 Nos) and 100A (01 Nos), not less than 30 cm in a separate Bus Bar chamber Volt Meter, 96mm2 flush type rated 0-500 V Digital type with instrument fuses & Volt slectro swithc with interconnections -01 Set , alongwith Amp-Meter, 96mm2 flush type rated 300A, digital type CT Operated with 03 Nos CTs and Amp Selector switch complete with inter connections -06 Sets , both in separate instumental chamber LED Indicating lamps R,Y,B-01 Set (a) MCCB 160 Amps , 4 Pole- 415 Volts /25 KA , 50Hz -01 No (I/C) (b) MCCB 63 Amps, 4 Pole, 415 Volts/16 KA , 50Hz -03 Nos (O/G)

2

-

-

... More
All as per above item no 38 but of following specification (a) MCCB 250 Amps , 4 Pole- 415 Volts /25 KA , 50Hz -01 No (I/C) (b) MCCB 160 Amps, 4 Pole, 415 Volts/16 KA , 50Hz -06 Nos (O/G) (c) Onload Change over switch 315A

1

-

-

... More
M&L in replacemnet of earthing complete with galvanised iron strip 32mm x 6mm and galvanised iron earth plate electrode 600x600x6mm thick, burried directly in ground(earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 2.25 meters below normal ground level, connected to galvanised earth lead wire 32x6mm dia by means of bolts, nuts, check nuts and washers of GI or steel and GI pipe 'L' grade of 40mm dia for protection of earth lead and 20mm dia GI pipe 'M' grade for watering with wire wash funnel etc as shown in electrical plate No. 5 of SSR part - I (2009) connected to earthing test point all as specified or indicated including testing on completion as per IE rule.

42

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.