Military Engineer Services Tender
Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.
Costs
EMD
₹ 2,32,000Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_682707_1Tender No
8946/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
(ix) Supply of 200 mm MS B-Class exhaust piping with insulation and aluminum sheet cladding on MS supports for extension to existing exhaust piping with bellows /connectors as required as required for the works. (x) Electric control panel with necessary wiring and all its accessories for smooth of DG with RECD system (xi) Support provided by OEM : Pre supply and inspection, Installation feasibility study at site, Health check-up of existing DG, Type Approved RECD with complete Solution, Educating Dept Staff on usage and operation and maintenance procedure. (xii) Installtion and commissioning of RECD by authrised and approved OEM only
-
-
-
Scope of work : (i) Emission control system with PRV, Inlet & outlet pipe, Structure with removable ladder and Electric panel with all accessories.
(ii) Performance / Characteristic curves at rated load - Under vendor scope
(iii) The output result of RECD shall be as per CPCB-II norms, irrespective of the manufacturer's technology
(vi) Secondary emission : Bidder shall submit the declaration that there is no secondary emission
(v) Noise emission : No increase in noise level after installation of retrofit device
(vi) No by-pass arrangement in RECD allowed to let the pollutants in open environment
(vii) Testing - Genset shall be tested on all load pattern available at site during post RECD installation
(viii) Warranty in all respect of 02 years post completion of work is applicable in RECD installation
(ix) Contractor shall furnish manufacturer's written instruction and requirement about use and maintenance of RECD system, its operation and maintenance schedule.
-
-
-
Notes :-(i) Retro-fit emission control system should be as per Statutory Authorities recommendations to achieve minimum specified particulate matter capturing efficiency of at least 70%. The emission control system shall be type tested and approved from CPCB approved laboratories as per guideline of NGT and MoHUA. (ii) Retro-Fit emission control system of suitable rating or sizes shall be installed or retrofitted in existing exhaust pipe with required modifications and suitable design compatible for respective model of diesel engine prime mover of DG sets and have safety precautions to ensure no damage to the engine operations under any circumstances (iii) Safety system provided to engine from higher back pressure, engine vibration, and high temperature operations to avoid any malfunction, it should be within the limits as recommended by DG OEM. The retrofit system manufacturer to coordinate and submit certificate from DG OEM.Cost for the same is deemed to be included in the quoted cost. (iv) The emission reduction will be verified after the installation of unit at site by any of the air pollution labs approved by CPCB.Contractor will submit the necessary certficate.Cost for the same is deemed to be included in the quoted cost.(v) The unit quoted cost includes all necessery RCC civil foundation/MS structure for installation of RECD structures as per recommendation of Manufacturer and as directed by GE. (vi) Make of existing DG set -Kirloskar Oil Engine Ltd/Greaves
-
-
-
All as per item No. 1.01 above but for capacity 380 KVA DG Set Note- Make of existing DG set -Kirloskar Oil Engine Ltd
1
-
-
All as per item No. 1.01 above but for capacity 250 KVA DG Set Note- Make of existing DG set -Greaves/Kirloskar Oil Engine Ltd
5
-
-
All as per item No. 1.01 above but for capacity 125 KVA DG Set Note- Make of existing DG set -Greaves
2
-
-
All as per item No. 1.01 above but for capacity 100 KVA DG Set Note- Make of existing DG set -Greaves
1
-
-
All as per item No. 1.01 above but for capacity 82.5 KVA DG Set Note- Make of existing DG set -Kirloskar Oil Engine Ltd
4
-
-
All as per item No. 1.01 above but for capacity 62.5 KVA DG Set and Emission limits as per CPCB-II norms : PM 2.5 0.3g/kW-hr, CO 3.5 g/KW-hr, Nox+HC 4.7 g/kW-hr Note- Make of existing DG set -Kirloskar Oil Engine Ltd
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%