Military Engineer Services Tender
Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.
Costs
EMD
₹ 70,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_658854_2Bid Award Id
ViewTender No
8935/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
M&L for 5mm thick cement plaster in cement mortar CM (1:3) on ceiling, and finished the surface even and smooth without using extra cement complete all as directed.
50
-
-
Dismantling and stripping the damaged wall of covering plaster by light chiseling and other manual methods until damp surfaces clean up. That might affect adhesion are to be removed by wire brushing. The entire exposed surface shall be washed thoroughly with plenty of clean water and then allowed to dry. (Dr. FIXIT / Fosroc / SIKA /HINDCON/ REDWOP Chemicals)
70
-
-
Sealing all surface shrinkage gaps on brick wall and pours shall be sealed with cementitious mortar mixed with a modified styrene butadiene emulsion. (Dr. FIXIT / Fosroc / SIKA / HINDCON/REDWOP Chemicals)
70
-
-
Supply and Applying single coat of Polycote NPW crystalline waterproofing System against negative sides of hydrostatic heads of water for damp proofing, apply by brush. (Dr. FIXIT / Fosroc / SIKA / HINDCON/REDWOP Chemicals )
70
-
-
Supply and Apply, covering plaster at removed damage wall surface for 10 mm thick with mixing ratio (1:4) Cement : Sand, adding adhesives styrene butadiene emulsion for plastering and finished the surface even and smooth all as directed by EIC. (Dr. FIXIT / Fosroc / SIKA / HINDCON/REDWOP Chemicals)
70
-
-
M&L three coats of white wash on newly plastered surfaces of ceiling including preparation of surfaces complete all as specified and as directed.
50
-
-
M&L preparation of old plaster surfaces and two coat of white wash on ceiling complete all as specified and as directed.
2000
-
-
All as per Sl Item No 1.009 but as in wall complete all as specified and as directed.
650
-
-
M&L for providing and applying wall care putty of 0.50mm to 1.0 mm thickness over plastered surface of wall to prepare the surface even and smooth.
410
-
-
M&L for preparation of new plastered surfaces of walls and applying two coats of acrylic distemper (ready mixed) having VOC content less than 50gms/litre of approved manufacturer of required shade and colour complete, as per manufacturer specification over a coat of alkali-resiatant primer complete all as specified and directed.
320
-
-
M&L for preparation of old plastered surface on wall and applying two coat of acrylic distemper including a coat of primer complete all as specified and as directed.
6810
-
-
M&L preparation of old surfaces and applying one coat of synthetic enamel paint to wooden surfaces over 10 cm width or girth complete all as specified and as directed.
1980
-
-
M&L preparation of old surfaces and applying one coat of synthetic enamel paint to steel surfaces over 10cm width or girth complete all as specified and as directed by EIC.
180
-
-
Dismantling floor hearth or wall tiling, granite stone including cement mortar bedding (but not backing) and rubbish off the premises.
355
-
-
M&L rendering 10mm thick cement plaster in CM (1:4) on fair faces of brick work for fixing of wall tiling.
102
-
-
M&L for 15 mm thick screed bed or bedding layer of mortar in CM (1:6) for laying floor finishes for non skid ceramic and granite tiles.
253
-
-
M&L Glazed ceramic colour tiles in vertical surface 450 x 300 x 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of tiles complete all as specified and directed.
80
-
-
M&L Non Skid colour ceramic tiles 7 to 8mm thick area of each tile exceeding 0.06 sqm but not exc 0.11 sqm in floors etc set & jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles complete all as specified and directed.
25
-
-
M&L Non Skid coloured ceramic tiles 7 to 8mm thick area of each tile exceeding 0.11 sqm but not exc 0.18 sqm in floors etc set & jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles complete all as specified and directed.
146
-
-
All as per Sl Item No 1.021 but in skirting.
15
-
-
M&L for Vitrified ceramic tiles 8 to 9mm thick light shade (Square/rectangular) polished area of each tiles not exceeding 0.36 Sqm, in floors etc set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of tiles complete all as specified and directed.
70
-
-
All as per Sl Item No. 1.023 but in skirting
7
-
-
M&L granite slab (of any type) 18-20 mm thick machine cut, bedded and jointed with gray cement slurry and pointed with white cement with admixture of pigments to match the shade of granite stone including cutting and polishing complete.
12
-
-
S&F in repairs stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples, etc. complete all as specified and as directed.
25
-
-
S&F Brass CP wall mixer of 15 mm dia for mixing hot & cold water screwed down for iron pipe and fixed in repair
6
-
-
Taking down chowkhats or frames with shutters (without taking off shutters from frame) area not exceeding 2.0 Sqm each complete all as directed.
5
-
-
S&F of solid PVC door frame of size 50mmx47mm made out of 5mm single side prelam PVC sheet & edges will be painted to match with prelam sheet reinforced with MS square tube, suppling and fixing in opening complete.
24
-
-
S&F of factory made solid panel PVC door shutter 30mm thick (Style) consisting of frame made out of M.S tubes for top and bottom rails. M.S frame shall be covered with heat moulded plain colour PVC 'C' channel moulded both side Prelam PVC sheet strip of 20mm width stuck inside with solvent cement for stiles prelam PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail; Panelling of both side Prelam PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement.
6.8
-
-
S&F 100 mm size of Stainless steel hinges complete all as specified and directed. (ISI Marked)
15
-
-
S&F 125 mm long extruded Aluminium alloy handles, fabricated type anodised complete all as specified and directed.
50
-
-
S&F 125 mm long extruded Aluminium anodized barrel tower bolt of extruded section and fixed complete all as specified and directed.
10
-
-
Taking up or down GI water tubing and connecting incl cleaning for refixing or removal to stores for 15mm bore.
60
-
-
Taking up or down GI water tubing and connecting incl cleaning for refixing or removal to stores for 20mm bore.
130
-
-
Supplying and laying of 20mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified.
60
-
-
Supplying and laying of 25mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified.
130
-
-
S&F in repairs wash down water closet (EWC) complete white with plastic water closet seat black closed pattern with flat bottom anc cover and mild steel chromium plated or aluminised hinging device and flush pipe of polythelene of low or density or PVC 32mm dia for low level flushing cistern complete
9
-
-
S&F Plastic water closet seat cover soft closed white with bottom and cover fixed with aluminium hinging device as in repair.
5
-
-
Supply and fix Vitreous china Squatting pan Orissa pattern of size 580mx440mm wite with integral foot rests (excluding flushing cistern and flush pipe) complete including concrete bedding as in repairs
5
-
-
Supply and fix PVC valveless syphonic action type flushing cistern 10 lit capacity low level white with inlet, ball valve, float and handle including brackets and 32mm PVC flush pipe in repairs.
15
-
-
S&F PVC connection 15mm size with PTMT nuts of length 600mm as in repair
15
-
-
S&F PVC connection 15mm size with PTMT nuts of length 450mm as in repair
12
-
-
S&F vitreous china wash basin, white, flat back size 550x400mm, incl cutting for and pinning in ends of brackets or erecting stand but excl taps, pvc conections but incl brackets, waste pipe, waste coupling in repairs
12
-
-
S&F sheet glass 3.00 mm thick, ordinary quality and glazing with beads fixed with metal/wood panel pin in square n exc 0.5 Sqm each as in repair
4
-
-
Dismantling water tanks of capacity exc 250 and n. exc 500 ltrs capacity.
6
-
-
Dismantling water tanks of capacity exc 500 and n. exc 1000 ltrs capacity.
5
-
-
S&F 500 litre capacity rotational moulded polythylene tripple layer water storage tank with cover and suitable locking arrangement (cylindrical vertical with closed top) ,ISI marked, hoisted and fixed in position all as per specified in SSR part-I.
6
-
-
S&F 1000 litre capacity rotational moulded polythylene tripple layer water storage tank with cover and suitable locking arrangement (cylindrical vertical with closed top) ,ISI marked, hoisted and fixed in position all as per specified in SSR part-I.
5
-
-
S&F PVC ball valves high pressure with polythene float and fly nut complete, screwed for iron pipe of 20mm bore in all as directed.
11
-
-
S&F in repair 15mm dia fancy type CP bib taps, cast copper alloy with crutch or butterfly handle, screwed down fixed all as directed.
15
-
-
S&F in repairs 15mm dia fancy type CP pillar taps, cast copper alloy with capstan head, chromium plated screwed down fixed high pressure, long screwed shanks and fly nuts, screwed for iron pipe all as directed.
18
-
-
S&F in repairs 15 mm dia CP concealed type stop valves/ angular stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or unions all as directed.
27
-
-
S&F stainless steel sink, 0.80mm thick for kitchen with plug, waste pipe, washer including cantilever cast iron bracket, connecting union overall size 915 mm x 460 mm with bowl size 410 mm x 330 mm x 160 mm fixed in repair
4
-
-
S&F stainless steel sink, 0.80mm thick for kitchen with plug, waste pipe, washer including cantilever cast iron bracket, connecting union overall size 495 mm x 420 mm with bowl size 410 mm x 330 mm x 160 mm fixed in repair
3
-
-
S&F 600mm x 450mm bevelled edge mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plug with chromium plated brass screws and cup washers without Aluminium frame fixed in repair
12
-
-
S&F Soap dish, any type, fixed to plugs with chromium plated brass screws complete as in repair all as specified and directed.
5
-
-
S&F in repairs Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified.
10
-
-
S&F sheet glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard railing 60 cm long in repairs.
8
-
-
S&F in repair shower rose fancy type chromium plated 120 mm (minimum) size with swivel joints suitable for 15 mm bore pipe including shower arm chromium plated 15 mm dia, 190 mm (minimum) long complete all as specified and directed.
8
-
-
S&F in repair Brass CP tubular towel rail, 20mm dia, "D" type, 60 cm long between flanges all as directed.
8
-
-
S&F in repair stainless steel fancy type 20mm dia curtain rod of 1.25mm thick wall thickness with bracket and all accessories (Note : Necessary bracket including in this items in every curtain rod to be fitted)
130
-
-
Dismantling boarding, any description, fixed in any position with screws complete all as specified and directed.
35
-
-
S&F 18-19 mm Venerred decorative plywood, grade1 (with BWR resin) with decorative face veneers on both faces, fixed with screws to timber frame work complete all as specified and directed.
30
-
-
S&F 18-19 mm Prelaminated particle board, interior grade, prelaminated both sides with decorative choice laminations fixed with screw to timber frame work including second class hardwood beading all around complete all as specified and directed.
5
-
-
M&L 2nd class hardwood Plain fillets. square, rectangular or triangular in section, clean sawn, secured with nails or brads of sectional area exc 6 Sqcm but n.exc 13 Sqcm incl 02 coats of synthetic enamel paint over a coat of primer including taking down old fillets all as directed.
40
-
-
S&F 100mm long Hasp and Staple, safety type, aluminium anodised with mild steel hinge pin including bolt to hinge plate and fixed with screws.
18
-
-
S&F 100 mm size aluminium anodised barrel tower bolt of extruded section complete all as specified and directed .
36
-
-
S&F continuous (piano) hinges, width of flaps 30mm, mild steel, bright finish or electro galvanised all as directed and specified.
70
-
-
S&F in repair 20 mm CPVC Ball Valve (Gate Valve) all as per specified and directed.
6
-
-
S&F in repair 25 mm CPVC Ball Valve all as per specified and directed.
8
-
-
SCHEDULE 'A' PART-II (E/M PORTION)
-
-
-
Taking down carefully copper / aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling rose, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc.
738
-
-
M&L Point wiring with two runs of FRLSH grade PVC insulated unsheathed mulri-stranded copper conductor of size 1.5 Sqmm (phase & neutral) and one run of 1.5 Sqmm FRLSH grade PVC insulated unsheathed multi-stranded copper conductor for earth continuity wire to be drawn in and including PVC rigid conduit (medium grade) of size not less than 20 mm dia concealed in wall / ceiling, etc. and conduit accessories with concealed wiring, sunk MS sheet metal switch/Terminal box 1.2 mm thick and hylum switch board cover 3.0 mm thick fixed with brass screws with cap washers for one light / fan point controlled by one 5/6 amps, one way switch including all necessary wall cutting and making good disturbed surface with cement mortar 1:6 or PCC 1:3:6, type C-0 and matching with existing surfaces complete all as directed and specified.
316
-
-
All as per item No. 2.002 above but for 5 Amps independent switch point wiring with 2 x 1.5 mm2 copper conductor cable as main wire and 1.5 mm2 copper conductor cable as earth continuity conductor.
118
-
-
All as per item No. 2.002 above but on same board for 5 Amps switch point wiring with 2 x 1.5 mm2 copper conductor cable and 1.5 mm2 copper conductor cable as earth continuity conductor.
66
-
-
All as per item No. 2.002 above but for 5 /15 Amps independent switch point wiring with 2 x 4.0 mm2 copper conductor cable and 4.0 mm2 copper conductor cable as earth continuity conductor.
63
-
-
All as per item No. 2.002 above but for one bell / buzzer point controlled by one push button on the same board with other switches independent with 1.5 mm2 copper conductor cables.
20
-
-
Taking down Sub main / Sub circuit wiring of any type and size including conduit / casing capping / batten wiring complete all as directed.
280
-
-
M&L for Submain / Sub circuit wiring using three runs of FRLSH grade PVC insulated unsheathed, multistranded, copper conductor cable of size 4 Sqmm to be drawn in and including PVC concealed conduit 25 mm dia (medium grade).
Note : Three runs of 4 Sqmm copper wire and one run of conduit pipe shall be measured as one unit.
220
-
-
All as per Ser Item No. 2.008 above but in PVC casing caping (medium duty) of size not less than 20 mm width.
Note : Three runs of 4 Sqmm copper wire and one run of casing caping shall be measured as one unit.
60
-
-
M&L Point wiring with two runs of FRLSH grade PVC insulated unsheathed mulri-stranded copper conductor of size 1.5 Sqmm (phase & neutral) and one run of 1.5 Sqmm FRLSH grade PVC insulated unsheathed multi-stranded copper conductor for earth continuity wire to be drawn in and including PVC casing caping (medium duty) of size not less than 20 mm width and accessories, sunk MS sheet metal switch / Terminal box 1.2 mm thick and hylum switch board cover 3.0 mm thick fixed with brass screws with cap washers for one light / fan point controlled by one 5/6 amps, one way switch including all necessary wall cutting and making good disturbed surface with cement mortar 1:6 or PCC 1:3:6, type C-0 and matching with existing surfaces complete all as directed and specified.
80
-
-
All as per item No. 2.010 above but for 5 Amps independent switch point wiring with 2 x 1.5 mm2 copper conductor cable as main wire and 1.5 mm2 copper conductor cable as earth continuity conductor.
32
-
-
All as per item No. 2.010 above but on same board for 5 Amps switch point wiring with 2 x 1.5 mm2 copper conductor cable and 1.5 mm2 copper conductor cable as earth continuity conductor.
18
-
-
All as per item No. 2.010 above but for 5 /15 Amps independent switch point wiring with 2 x 4 mm2 copper conductor cable and 4.0 mm2 copper conductor cable as earth continuity conductor.
20
-
-
All as per item No. 2.010 above but for one bell / buzzer point controlled by one push button on the same board with other switches or independent with 1.5 mm2 copper conductor cables.
5
-
-
S&F Switch piano, flush type, single pole, one way 5 Amps, 240V complete all as directed by Engineer-in-Charge.
438
-
-
Fixing in repair switch piano, flush type single pole, one way 5 Amps including connection.
42
-
-
S&F as inreplacement of call bell Dingdong, 230V AC, single pole
25
-
-
S&F Switch piano, flush type, single pole, one way 15 Amps, 240V complete all as directed by Engineer-in-Charge.
38
-
-
Fixing in repair switch piano, flush type single pole, one way 15 Amps including connection.
5
-
-
S&F as inreplacement bell push, flush type, 5 Amp.
25
-
-
M&L as inreplacement switch socket combination 2 in 1, 5 Amps flush type including connection.
137
-
-
Fixing in repair switch socket combination 2 in 1, 5 Amps flush type including connection.
13
-
-
M&L as inreplacement switch socket combination multipurpose 5 in 1, 5/16 Amps controlled by one switch.
40
-
-
Fixing in repair switch socket combination multipurpose 5 in 1, 5/16 Amps controlled by one switch.
5
-
-
M&L as inreplacement socket outlet 2 in 1, 3 pin, 5 amp flush type controlled by one switch.
142
-
-
Fixing in repair switch socket outlet 2 in 1, 3 pin, 5 amp flush type controlled by one switch.
8
-
-
M&L as inreplacement socket outlet 2 in 1, 3 pin, 5 and 15 amp flush type controlled by one switch.
38
-
-
Fixing in repair switch socket outlet 2 in 1, 3 pin, 5 and 15 amp flush type controlled by one switch.
5
-
-
M&L as in replacement ceiling rose PVC poly carbonate, isolated body with three terminals including connection.
196
-
-
M&L as in replacement stepped type electronic fan requlator flush type 230/240 volts complete all as specified.
52
-
-
Fixing in repair stepped type electronic fan requlator flush type 230/240 volts complete all as specified.
6
-
-
M&L as in replacement lamp holder angular type PVC / Polycarbonate type insulated body with back plate suitable for batten fittings.
145
-
-
Fixing in repair lamp holder angular type PVC / Polycarbonate type insulated body with back plate suitable for batten fittings.
10
-
-
S&F in repair LED type intigrated batten fitting indoor decorative polycarbonate housing & diffuser with integrated LED driver 20W white all as directed.
91
-
-
All as per Item No. 2.034 above but 10W.
10
-
-
Taking down ceiling fan of any type, any make and any sweep for repairing, opening the body and blade, checking for repalcement of unserviceable minor spares like nut, bolt, bush, clamp & down rod as required and cleaning, overoiling, greasing, replacement of unserviceable spare by new one, re-assembling of all components in original position, testing and hanging up the same complete all as specified and as directed by the Engr-in-Charge.
Note : New spare parts required for replacement shall be measured and paid seperately as 'Supply only"
89
-
-
Supply only Ball bearing of size 6201/6202/6203 for ceiling fan of 1200/1400mm Sweep complete all as specified and as directed.
Make : TATA / SKF
40
-
-
Taking down exhaust fan of any type, any make and any sweep for repairing, opening the body and blade, checking for repalcement of unserviceable minor spares like nut,bolt,bush & clamp as required and cleaning, overoiling, greasing, replacement of unserviceable spare by new one, re-assembling of all components in original position, testing and fixing up the same complete all as specified and as directed.
Note : New spare parts required for replacement shall be measured and paid seperately as 'Supply only"
32
-
-
Supply only Ball bearing 2001 / 2002 / 2003 for exhaust fans complete all as specified and as directed.
Make : TATA / SKF
13
-
-
Supply only capacitor 220 volts, 2.5 mfd suitable for ceiling fan.
Make : SARADA / TIBOCON / UNIVERSAL.
60
-
-
All as per item No. 2.040 above but 3.5 mfd capacity and ditto.
15
-
-
S&F in repair Hanging clamp for ceiling fan with MS flat of size 25 x 3 mm and 250mm long including rubber reel, nuts, bolts and washers etc. complete including taking down old unserviceable one, all as directed.
32
-
-
Material and labour for painting of ceiling fan of size 1200mm/ 1400mm sweep with down rod upto 2.00 mtr long with two coats of synthetic enamel spray white paint including preparation old painted surface including writing of MES No. with letters not exceeding 15cm height complete all as specified and as directed.
40
-
-
Material and labour for painting of Exhaust fan of of sweep 230mm to 450mmm with two coats of synthetic enamel spray white paint including preparation old painted surface including writing of MES No. with letters not exceeding 15cm height complete all as specified and as directed.
16
-
-
Rewinding of ceiling fan, 1200mm and 1400mm sweep with synthetic enamel copper wire including insulation of starter with polyster paper / manllex paper with cotontak binding, heat varnished and complete all as specified and as directed.
43
-
-
All as per item No. 2.045 above but for exhaust fan of sweep 230mm to 450mmm.
15
-
-
Supply and fixing as in replacement M.S. galvanised louvers suitable for exhust fan of size 300/230mm sweep complete all as specified and as directed.
23
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements