Military Engineer Services Tender
Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.
Costs
EMD
₹ 50,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_671885_1Bid Award Id
ViewTender No
8965/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
M&L for Glazed ceramic coloured tiles 450 X 300 X 7mm thick set coloured tiles as in dado, skirting and vertical surfaces set and jointed in neat cement slurry and pointed in white or coloured cement to match with tiles, complete all as specified and directed.
50
-
-
M&L for Non Skid coloured ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.06 sqm but not exc 0.11 sqm in floors etc set & jointed in neat cement slurry and pointed in coloured cement, complete all as specified and directed.
15
-
-
M&L for Non Skid coloured ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exc 0.18 sqm in floors etc set & jointed in neat cement slurry and pointed in coloured cement, complete all as specified and directed.
75
-
-
Ditto all as per item 6 but in skirting, complete all as specified and directed.
7
-
-
M&L for vertified ceramic tiles 8 to 9 mm thick light shade (Square/ rectangular) polished area of each tiles exceeding 0.18 sqm but not exceeding 0.36 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or colour cement to match, complete all as specified and directed.
40
-
-
Ditto all as per item 8 but in skirting, complete all as specified and directed.
4
-
-
M&L for vertified ceramic tiles 8 to 9 mm thick light shade (Square/ rectangular) polished area of each tiles exceeding 0.42 Sqm but not exceeding 1.00 Sqm, in floors etc set and jointed in neat cement slurry and pointed in white or colour cement to match, complete all as specified and directed.
10
-
-
S&F fix in repairs grating doom 125 mm dia size of PTMT (minimum weight 40gms), complete all as specified and directed.
10
-
-
S&F PVC connection of 15mm size with PTMT nuts of length 600mm long complete all as specified and as directed.
9
-
-
S&F in repairs 10 Liters capacity, low level flusing cistern, PVC, white, with inlet ball valve, float, handle, flush pipe of polyethylene of low or high density of PVC, 32mm dia including brackets and connections to pipe, complete all as specified and as directed.
5
-
-
S&F in repairs wash down water closet (EWC) complete white with plastic water closet seat black closed pattern with flat bottom anc cover and mild steel chromium plated or aluminised hinging device and flush pipe of polythelene of low or density or PVC 32mm dia for low level flushing cistern, complete all as specified and directed.
5
-
-
S&F in repairs Vitreous china Squatting pan Orissa pattern of size 580mx440mm white with integral foot rests (excluding flushing cistern and flush pipe) complete including concrete bedding, complete all as specified and directed.
3
-
-
S&F in repairs vitreous china wash basin, white, flat back size 550x400mm, incl cutting for and pinning in ends of brackets or erecting stand but excl taps, pvc conections but incl brackets, waste pipe, waste coupling, complete all as specified and directed.
4
-
-
S&F in repair 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to walls including necessary brackets clamps or laid in trenches, complete all as specified and as directed.
18
-
-
S&F in repairs 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to walls including necessary brackets clamps or laid in trenches, complete all as specified and as directed.
20
-
-
S&F in repair 75mm bore PVC (SWR) junction single (Single "T") equal or unequal with access door, complete all as specified and as directed.
4
-
-
All as per item No 19 above but 110mm, complete all as specified and as directed.
5
-
-
S&F in repairs 75mm bore PVC (SWR) bends of any radius, complete all as specified and as directed.
7
-
-
All as per item No 21 above but 110mm, complete all as specified and as directed.
9
-
-
Taking down of steel tubing 15mm dia of pipe and connections, complete all as specified and as directed.
60
-
-
All as per item No 23 above but 20 mm, complete all as specified and as directed.
130
-
-
Supply and fix of 20 mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors, complete all as specified and as directed.
60
-
-
All as per item No 25 above but 25mm outer dia, complete all as specified and as directed.
130
-
-
Cutting chases, pinning in. making good to facings where required & pointing in cement mortar CM (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc. and cutting chases for concealed water tubing etc., and making good, cutting not exc 15 cm girth, complete all as specified and as directed.
60
-
-
S&F in repair 15mm dia fancy type CP bib taps, cast copper alloy with crutch or butterfly handle, screwed down, complete all as specified and as directed.
8
-
-
S&F in repairs 15mm dia fancy type CP pillar taps, cast copper alloy with capstan head, chromium plated screwed down fixed high pressure, long screwed shanks and fly nuts, screwed for iron pipe, complete all as specified and as directed.
6
-
-
S&F in repairs 15 mm dia CP concealed type stop valves/ angular stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or unions, complete all as specified and as directed.
8
-
-
Dismantling timber scantlings 40 sq. cm and over in section, in any position, complete all as specified and as directed.
1
-
-
Taking down asbestos cement corrugated or semi corrugated sheet in roof covering, complete all as specified and directed
320
-
-
S&F for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240, complete all as specified and as directed.
1050
-
-
M&L for applying two coat of synthetic enamel paint on new steel surface over a coat of red oxide incl preparation of surface of any description over 10 cm width or girth, complete all as specified and as directed.
75
-
-
M&L 0.50 mm thick pre painted galvalume aluminium zinc coating GI based corrugated steel sheet of any colour as in roof covering with self tapping screws, complete all as specified and as directed.
290
-
-
M&L 0.50 mm thick pre painted galvalume aluminium zinc coating GI based Plain steel sheet of any colour as in roof covering with self tapping screws, complete all as specified and as directed.
30
-
-
Taking out existing roof treatment and taking out existing plaster and wire brushing and cleaning the existing surface with water etc and removing rubbish to a distance not exceeding 1.50 Km, complete all as specified and as directed.
420
-
-
M&L for 25mm thick PCC (1:2:4), type B-0, (using 12.5mm graded stone aggregate), complete all as specified and as directed.
150
-
-
M&L for 3mm thick APP modified non-woven polyester reinforced bituminous membrane with mineral slate granules and flexible at -2 °C (Sika shield P 24 MG or equivalent) water proofing membrane weight not less than 3 Kg/sqm including one coat of bituminous primer for bitumen membrane @ 0.4 lit/sqm over plaster surface. Over the primer coat the membrane shall be laid using butane torch and sealing all the joints etc complete all as specified and directed. Note : The laying of membrane shall be got done through the authorised applicator of the manufacturer.
420
-
-
M&L for rendering 15 mm thick on brick work or concrete surfaces in cement mortar (1:4) finished surfaces even and smooth with WPC complete all as specified and as directed. (Note : WPC shall be measured and paid separately)
420
-
-
Treating existing water proofing roof treatment comprising the following specification and as directed :-
(a) Dismantling and stripping of Existing Roof treatment for damaged concrete of covering plaster by light chiseling until sound surfaces come up. That might affect adhesion are to be removed by wire brushing. The entire exposed surface shall be washed thoroughly with plenty of Clean water and then allowed to dry. Smooth concrete surfaces if any to be Roughened mechanically. ( Dr. FIXIT / Fosroc / SIKA / REDWOP Chemicals) (b) Sealing all surface shrinkage cracks on roof and pours shall be sealed with cementitious mortar mixed with A modified styrene butadiene emulsion. (Dr. FIXIT / Fosroc / SIKA/ REDWOP Chemicals)
(c) Supply and Apply, screed covering(PCC) (Cement / sand / aggregate 6mm down) average thickness of 25-30mm admixed with Plastcone AW+- integral waterproofing compound 150ml per 50 kg bag of cement & adding adhesives styrene butadiene emulsion with cement slurry to a uniform slope for easy drainage of water. ( Dr. FIXIT / Fosroc / SIKA / REDWOP Chemicals)
(d) Supply and Applying single coat of Acrylic based co-polymer for filling up surface pours by a brush on cleaned rendered sub substrate as priming coat. The coating needs to be prepared by mixing Acrylic based copolymer /Cement/water in ration 1 : 2 : 4 v/v. ( Dr. FIXIT / Fosroc / SIKA / REDWOP Chemical)
(e) Supply and applying two coats of POLYCOTE BB-X (white) is a two Component acrylic polymer modified elastomeric ,Waterproofing membrane with high Elongation ( 150% ) on top of screed by brush without Water dilution. ( Dr. FIXIT/Fosroc/SIKA/REDWOP)
510
-
-
Dismantling and stripping the damaged concrete of Column, beam, facia and slab etc. incl. covering plaster by light chiselling and other manual methods until sound concrete surfaces come up. Any trace of loose plaster, oil / grease, and moss / funguses if any or other materials that might affect adhesion are to be removed by wire brushing. The entire exposed surface shall then be washed thoroughly with plenty of clean water and then allowed to dry. Smooth concrete surfaces if any to be roughened mechanically, complete all as specified and as directed (Dr FIXIT/Fosroc/SIKA)
1.9
-
-
Epoxing the corroded reinforcement completely along its full circumference, cleaned to remove all loose scale and corrosion deposit applying rust removing chemical followd by removing the rust by emergy paper and cleaning the area thoroughly by water and allow it to dry. Sand blasting to remove residual deposit if necessary as per directive of manufacturer's instruction, complete all as specified and as directed (Dr FIXIT/Fosroc/SIKA)
14
-
-
Supply and Application of Epoxy Zinc rich primer on the prepared reinforced surface by brush, upto 4 storey height, the primer should have a minimum Specific gravity 1.75, minimum wet film thickness/coat 100 microns & Dry film thickness/coat 40 microns. Minimum Adhesive bond strength with steel is 1.5 N/mm2, complete all as specified and as directed (Dr FIXIT/Fosroc/SIKA))
14
-
-
Supply and fix of new TMT bars of approved Brand of requisite diameter by electro welding of length 25 to 5d on both the sides with the existing bar to required size and shape at the portion where the existing reinforcement has lost half of its sectional area followed by a coat of Epoxy Zinc rich primer as per the specification (Dr FIXIT/Fosroc/SIKA)
30
-
-
Formwork of smooth finish surfaces of column, beam, facia, slab etc. with required bracing / support incl. fixing and striking out after pouring of concrete at all levels with necessary scaffolding and staging, complete all as specified and as directed
23
-
-
Supply and Application Free flow non-shrink cementitious micro concrete to the affected beam, Column etc. where major spalling has taken place even the core concrete affected. The Micro concrete should have a Minimum 1day Compressive strength of 10 MPa and 28 days strength of 50 MPa, Minimum Tensile strength 2.0N/mm2 @ 28 days, Minimum Flexural strength 5N/mm2 @ 28 days tested as per BS4551 - 80, Expansion characteristics Unrestrained expansion As per ASTM C827 - 1987 1 to 4%. A general purpose Epoxy Bonding agent to be applied on the concrete surface before the application the mortar. The bonding agent should have minimum compressive strength 40 N/mm2 as per BS6319 Part 7. Minimum Flexral Strength 25 N/mm2 as per BS 6319 Part 3 and minimum bond strength as per ASTM C88111 N/mm2(Dr FIXIT/Fosroc/SIKA Chemicals).
1.18
-
-
Supply and Application Two component structural grade polymer modified reinstatement mortar where local spalling has taken place or shuttering is not possible. The Mortar can be applied from a minimum of 5mm to 15mm thickness in smaller vertical pockets and upto 100 mm thickness in horizontal applications. The mortar should have a minimum Compressive strength 12 N/mm2 in 1 Day and 45 N/mm2 in 28days. Minimum Flexural strength should be 8N/mm2 in 28 days.A modified styrene butadiene emulsion for use as a bonding aid and gauging liquid for cementitious systems to be mixed with cement slurry before the application of microconcrete to be used @ 6lit/bag of cement. The Bonding agent should have minimum Compressive Strength 24 N/mm2.Minimum Tensile Strength 3.5 N/mm2. Minimum Flexural Strength 6.5 N/mm2. Note: The Rate is based on an avg thickness. (Dr FIXIT/Fosroc/SIKA Chemicals)
24
-
-
Supply and Application Two component high build polymer modified cementitious reinstatement mortar where local spalling has taken place or shuttering is not possible. The Mortar can be applied in thicknesses from 15mm to 40mm thickness in vertical and 25mm in overhead situations. The Mortar should have a minimum Compressive strength 7 N/mm2 in 1 Day and 20 N/mm2 in 28days. Minimum Flexural strength should be 4.5 N/mm2 in 28 days. Minimum Tensile strength should be 1.7 N/mm2 in 28days. A general purpose epoxy bonding agent to be applied on the concrete surface before the application of mortar. The Bonding agent should have minimum Compressive Strength 40 N/mm2 as per BS 6319 Part 2. Minimum Tensile Strength 15N/mm2 as per BS6319 Part 7. Minimum Flexural Strength 25 N/mm2 as per BS 6319 Part-3 and Minimum Bond strength as per ASTM C881 11N/mm2. Note: The Rate is based on an avg. Thickness of 15mm.(Dr FIXIT/Fosroc/SIKA Chemicals)
20
-
-
M&L Applying Concure LP90 or equivalent over concrete and cement plaster as curing compound complete as per manufacturers instrcn, complete all as specified and as directed
57
-
-
M&L for removing the plant from walls & roof of the building with complete roots, applying recommended chemicals to prevent further growth as directed, making good the disturbed surface with PCC 1:2:4 and CM 1:3 and applying surface finishs to match the existing surface including removal of debris etc outside the premises complete all as specified & directed.
100
-
-
Demolition of brick work built in cement mortar incl quoin, arches etc, complete all as specified and directed.
4.5
-
-
M&L for brick work with flyash bricks old size, straight or curved on plan exc 6 m mean radius built in cement mortar CM (1:4), complete all as specified & directed.
4
-
-
All as per item No. 53 but except bricks (bricks obtained from item No - 52), complete all as specified & directed.
0.5
-
-
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified & directed.
150
-
-
M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar CM (1:6) and finished even and smooth without using extra cement, complete all as specified & directed.
50
-
-
M&L for 5 mm thick cement plaster in cement mortar CM (1:3) of ceiling, finished even and smooth without using extra cement, complete all as specified & directed.
20
-
-
M&L for rendering 15 mm thick on brick work or concrete surfaces in cement mortar CM (1:4) finished surfaces even and smooth, complete all as specified and as directed.
110
-
-
M&L three coats of white wash on newly plastered surfaces of ceiling including preparation of surfaces, complete all as specified and as directed.
40
-
-
M&L for preparation of new plastered surfaces of walls applying 1mm thick wall care putty to achieve smooth surface rubbing with sand paper and applying two coats of acrylic distemper over a coat of alkali-resiatant primer, complete all as specified and directed.
50
-
-
M&L for Finishing walls with Acrylic Smooth exterior coat paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm), complete all as specified and directed.
140
-
-
Demolition of cement concrete of any description and in any position not otherwise specifically provided for and removing rubbish to a distance not exceeding 1.50 Km complete all as specified and as directed.
6.5
-
-
M&L for rendering 10mm thick in cement mortar CM (1:4) on internal wall brick / concrete surfaces, finished even and smooth without using extra cement, complete all as specified and directed.
10
-
-
M&L for applying evenly a priming/tack coat with bituminous primer at 10 Kg per 10 Sq.m, complete all as specified and directed.
1
-
-
M&L for Sand filling under sunken floors or in foundations including watering and consolidation, complete all as specified and directed.
0.6
-
-
M&L for PCC (1:5:10) type E-2, using 40mm graded aggregate as in filling in Sunken floor, complete all as specified and directed.
1.5
-
-
M&L for 30mm thick PCC (1:2:4), type B-0, using 12.5mm graded aggregate as in sunken floor flooring, complete all as specified and directed.
10
-
-
Supply only integral water proofing compound (ISI marked) of approved make.
16
-
-
Disconnecting existing 500 or 1000 ltr tanks, setting aside (or lowering if required) for repairs and sifting to other place incl all required dammaged part of tanks, cleaning, etc. and hoisting if required reconnecting and re-fixing in position, complete all as specified and directed.
18
-
-
Demolition of unserviceable RCC over head tank (reinforcement cut as required to facilitate demolition) concrete of any description and in any position not otherwise specifically provided and remove the debris from the site complete all as specified and directed.
6
-
-
M&L 75 mm thick Cement concrete type C-1, (1:3:6) (using 20mm graded aggregate) with water proofing compound for PVC water tanks, complete all as specified and directed.
20
-
-
Dismantling water tanks of capacity exc 250 and n. exc 500 ltrs capacity, complete all as specified and directed.
4
-
-
S&F 500 litre capacity rotational moulded polythylene tripple layer water storage tank with cover and suitable locking arrangement (cylindrical vertical with closed top) hoisted and fixed in position all as per specified in SSR part-I, complete all as specified and directed.
4
-
-
S&F PVC ball valves high pressure with polythene float and fly nut complete, screwed for iron pipe of 20mm bore, complete all as specified and directed.
4
-
-
S&F in repair 20 mm CPVC Ball Valve (Gate Valve), complete all as specified and directed.
5
-
-
S&F in repair 25 mm CPVC Ball Valve (Gate Valve), complete all as specified and directed.
3
-
-
Schedule of Credit
-