Indian Oil Corporation Limited Tender

... More
Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.

Indian Oil Corporation Limited - IOCL Tender

Goods
Energy, Oil and Gas
Eprocure
Opening Date28 Apr 2020
Closing Date8 Jun 2020
Tender AmountRefer Documents 
Notes
Download

Summary

Supply Of Special Check Valve (lot-3)

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
NOZZLE CHK VALVE,CS (NACE), 150,0, MFR. STD., FLGD, B16.5, RF, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A216 Gr.WCB, API 600 12, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, NACE REQ. ACC. TO NACE MR-0103, AND DOC.NO. PDRP-8440-SP-0026, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.

1

-

-

... More
NOZZLE CHK VALVE,AS (H2), 1500,0, MFR. STD., FLGD, B16.5, RTJ, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A217 Gr.WC6, API 600 5, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 25284124-8230-SP-000-0007, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.

1

-

-

... More
NOZZLE CHK VALVE,AS (H2), 1500,0, MFR. STD., FLGD, B16.5, RTJ, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A217 Gr.WC6, API 600 5, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 25284124-8230-SP-000-0007, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.

1

-

-

... More
NOZZLE CHK VALVE,AS (H2), 900,0, MFR. STD., FLGD, B16.5, RTJ, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A217 Gr.WC6, API 600 5, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 25284124-8230-SP-000-0007, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.

1

-

-

... More
NOZZLE CHK VALVE,AS (H2), 900,0, MFR. STD., FLGD, B16.5, RTJ, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A217 Gr.WC6, API 600 5, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 25284124-8230-SP-000-0007, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.

1

-

-

... More
NOZZLE CHK VALVE,CS (H2), 600,0, MFR. STD., FLGD, B16.5, RF, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A216 Gr.WCB, API 600 8, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 25284124-8230-SP-000-0007, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.

1

-

-

... More
NOZZLE CHK VALVE,CS (H2), 600,0, MFR. STD., FLGD, B16.5, RF, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A216 Gr.WCB, API 600 8, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 25284124-8230-SP-000-0007, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.

1

-

-

... More
NOZZLE CHK VALVE,CS (H2), 600,0, MFR. STD., FLGD, B16.5, RF, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A216 Gr.WCB, API 600 8, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 25284124-8230-SP-000-0007, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.

1

-

-

... More
NOZZLE CHK VALVE,CS, 600,0, MFR. STD., FLGD, B16.5, RF, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A216 Gr.WCB, API 600 8, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.

1

-

-

... More
NOZZLE CHK VALVE,SS, 600,0, MFR. STD., FLGD, B16.5, RTJ, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A351 Gr.CF8C, SS 321H + HF, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, CARBON CONTENT SHALL BE 0.04% OR HIGHER, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.

1

-

-

... More
NOZZLE CHK VALVE,CS (IBR), 600,0, MFR. STD., FLGD, B16.5, RF, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A216 Gr.WCB, API 600 5, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, IBR CERTIFICATE IN FORM IIIC REQUIRED., REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.

1

-

-

... More
NOZZLE CHK VALVE,SS, 150,0, MFR. STD., FLGD, B16.5, RF, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A351 Gr.CF8, API 600 12, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.

1

-

-

... More
NOZZLE CHK VALVE,AS (H2), 900,0, MFR. STD., FLGD, B16.5, RTJ, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A217 Gr.WC6, API 600 5, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 25284124-8230-SP-000-0007, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.

1

-

-

... More
NOZZLE CHK VALVE,SS, 300,0, MFR. STD., FLGD, B16.5, RF, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A351 Gr.CF8, API 600 12, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.

1

-

-

... More
NOZZLE CHK VALVE,AS(NACE+H2), 1500,0, MFR. STD., FLGD, B16.5, RTJ, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A217 Gr.WC6, API 600 12, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, NACE REQ. ACC. TO NACE MR-0103, AND DOC.NO. PDRP-8440-SP-0026, ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 25284124-8230-SP-000-0007, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.

1

-

-

... More
NOZZLE CHK VALVE,AS (H2), 900,0, MFR. STD., FLGD, B16.5, RTJ, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A217 Gr.WC6, API 600 5, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 25284124-8230-SP-000-0007, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.

1

-

-

... More
NOZZLE CHK VALVE,AS (IBR), 600,0, MFR. STD., FLGD, B16.5, RF, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A217 Gr.WC6, API 600 5, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, IBR CERTIFICATE IN FORM IIIC REQUIRED., REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.

2

-

-

... More
NOZZLE CHK VALVE,AS (H2), 900,0, MFR. STD., FLGD, B16.5, RTJ, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A217 Gr.WC6, API 600 5, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 25284124-8230-SP-000-0007, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.

1

-

-

... More
NOZZLE CHK VALVE,CS, 300,0, MFR. STD., FLGD, B16.5, RF, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A216 Gr.WCB, API 600 8, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.

1

-

-

... More
NOZZLE CHK VALVE,SS, 600,0, MFR. STD., FLGD, B16.5, RTJ, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A351 Gr.CF8C, SS 321H + HF, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, CARBON CONTENT SHALL BE 0.04% OR HIGHER, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.

1

-

-

... More
NOZZLE CHK VALVE,SS, 600,0, MFR. STD., FLGD, B16.5, RTJ, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A351 Gr.CF8C, SS 321H + HF, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, CARBON CONTENT SHALL BE 0.04% OR HIGHER, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.

1

-

-

... More
NOZZLE CHK VALVE,AS (H2), 1500,0, MFR. STD., FLGD, B16.5, RTJ, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A217 Gr.WC6, API 600 5, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 25284124-8230-SP-000-0007, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.

1

-

-

... More
NOZZLE CHK VALVE,CS, 150,0, MFR. STD., FLGD, B16.5, RF, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A216 Gr.WCB, API 600 8, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.

1

-

-

... More
NOZZLE CHK VALVE,CS (NACE), 600,0, MFR. STD., FLGD, B16.5, RF, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A216 Gr.WCB, API 600 12, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, NACE REQ. ACC. TO NACE MR-0103, AND DOC.NO. PDRP-8440-SP-0026, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.

2

-

-

... More
NOZZLE CHK VALVE,AS (H2), 1500,0, MFR. STD., FLGD, B16.5, RTJ, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A217 Gr.WC6, API 600 5, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 25284124-8230-SP-000-0007, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.

1

-

-

... More
NOZZLE CHK VALVE,AS (H2), 1500,0, MFR. STD., FLGD, B16.5, RTJ, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A217 Gr.WC6, API 600 5, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 25284124-8230-SP-000-0007, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.

1

-

-

... More
NOZZLE CHK VALVE,CS (NACE), 600,0, MFR. STD., FLGD, B16.5, RF, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A216 Gr.WCB, API 600 12, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, NACE REQ. ACC. TO NACE MR-0103, AND DOC.NO. PDRP-8440-SP-0026, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.

1

-

-

... More
NOZZLE CHK VALVE,CS (NACE), 600,0, MFR. STD., FLGD, B16.5, RF, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A216 Gr.WCB, API 600 12, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, NACE REQ. ACC. TO NACE MR-0103, AND DOC.NO. PDRP-8440-SP-0026, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.

1

-

-

... More
NOZZLE CHK VALVE,CS, 300,0, MFR. STD., FLGD, B16.5, RF, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A216 Gr.WCB, API 600 8, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.

1

-

-

... More
NOZZLE CHK VALVE,CS, 300,0, MFR. STD., FLGD, B16.5, RF, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A216 Gr.WCB, API 600 8, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.

1

-

-

... More
NOZZLE CHK VALVE,CS (H2), 600,0, MFR. STD., FLGD, B16.5, RF, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A216 Gr.WCB, API 600 8, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 25284124-8230-SP-000-0007, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.

1

-

-

... More
NOZZLE CHK VALVE,CS, 600,0, MFR. STD., FLGD, B16.5, RF, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A216 Gr.WCB, API 600 8, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.

1

-

-

... More
NOZZLE CHK VALVE,CS (H2), 600,0, MFR. STD., FLGD, B16.5, RF, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A216 Gr.WCB, API 600 8, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 25284124-8230-SP-000-0007, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.

1

-

-

... More
NOZZLE CHK VALVE,CS (H2), 600,0, MFR. STD., FLGD, B16.5, RF, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A216 Gr.WCB, API 600 8, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 25284124-8230-SP-000-0007, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.

1

-

-

... More
NOZZLE CHK VALVE,CS (H2), 600,0, MFR. STD., FLGD, B16.5, RF, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A216 Gr.WCB, API 600 8, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 25284124-8230-SP-000-0007, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.

1

-

-

... More
NOZZLE CHK VALVE,CS(NACE+H2), 600,0, MFR. STD., FLGD, B16.5, RF, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A216 Gr.WCB, API 600 12, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, NACE REQ. ACC. TO NACE MR-0103, AND DOC.NO. PDRP-8440-SP-0026, ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 25284124-8230-SP-000-0007, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.

1

-

-

... More
NOZZLE CHK VALVE,CS (H2), 600,0, MFR. STD., FLGD, B16.5, RF, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A216 Gr.WCB, API 600 8, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 25284124-8230-SP-000-0007, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.

1

-

-

... More
NOZZLE CHK VALVE,CS (H2), 300,0, MFR. STD., FLGD, B16.5, RF, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A216 Gr.WCB, API 600 8, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 25284124-8230-SP-000-0007, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.

1

-

-

... More
NOZZLE CHK VALVE,LTCS,NACE, 150,0, MFR. STD., FLGD, B16.5, RF, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A352 Gr.LCB, API 600 12, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, NACE REQ. ACC. TO NACE MR-0103, AND DOC.NO. PDRP-8440-SP-0026, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.

1

-

-

... More
NOZZLE CHK VALVE,LTCS,NACE, 300,0, MFR. STD., FLGD, B16.5, RF, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A352 Gr.LCB, API 600 12, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, NACE REQ. ACC. TO NACE MR-0103, AND DOC.NO. PDRP-8440-SP-0026, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.

1

-

-

... More
NOZZLE CHK VALVE,LTCS,NACE, 300,0, MFR. STD., FLGD, B16.5, RF, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A352 Gr.LCB, API 600 12, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, NACE REQ. ACC. TO NACE MR-0103, AND DOC.NO. PDRP-8440-SP-0026, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.

1

-

-

... More
NOZZLE CHK VALVE,CS, 150,0, MFR. STD., FLGD, B16.5, RF, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A216 Gr.WCB, API 600 8, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.