Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.
Indian Oil Corporation Limited - IOCL Tender
Energy, Oil and Gas
Eprocure
Opening Date28 Apr 2020
Closing Date8 Jun 2020
Tender AmountRefer Documents
Costs
EMD
Refer DocumentsDocument Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Supply Of Special Check Valve (lot-3)
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2020_REFHQ_116165_1Bid Award Id
ViewTender No
25284124-8230-RQ-000-0133Tender Authority
Indian Oil Corporation Limited ViewPurchaser Address
-Website
http://https://www.iocl.com/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Special_Instructions_to_the_Bidders_20200228
Tech_Specs_Confirmation_Sheet
BOQ Items
... More
NOZZLE CHK VALVE,CS (NACE), 150,0, MFR. STD., FLGD, B16.5, RF, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A216 Gr.WCB, API 600 12, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, NACE REQ. ACC. TO NACE MR-0103, AND DOC.NO. PDRP-8440-SP-0026, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.
1
-
-
... More
NOZZLE CHK VALVE,AS (H2), 1500,0, MFR. STD., FLGD, B16.5, RTJ, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A217 Gr.WC6, API 600 5, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 25284124-8230-SP-000-0007, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.
1
-
-
... More
NOZZLE CHK VALVE,AS (H2), 1500,0, MFR. STD., FLGD, B16.5, RTJ, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A217 Gr.WC6, API 600 5, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 25284124-8230-SP-000-0007, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.
1
-
-
... More
NOZZLE CHK VALVE,AS (H2), 900,0, MFR. STD., FLGD, B16.5, RTJ, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A217 Gr.WC6, API 600 5, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 25284124-8230-SP-000-0007, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.
1
-
-
... More
NOZZLE CHK VALVE,AS (H2), 900,0, MFR. STD., FLGD, B16.5, RTJ, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A217 Gr.WC6, API 600 5, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 25284124-8230-SP-000-0007, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.
1
-
-
... More
NOZZLE CHK VALVE,CS (H2), 600,0, MFR. STD., FLGD, B16.5, RF, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A216 Gr.WCB, API 600 8, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 25284124-8230-SP-000-0007, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.
1
-
-
... More
NOZZLE CHK VALVE,CS (H2), 600,0, MFR. STD., FLGD, B16.5, RF, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A216 Gr.WCB, API 600 8, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 25284124-8230-SP-000-0007, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.
1
-
-
... More
NOZZLE CHK VALVE,CS (H2), 600,0, MFR. STD., FLGD, B16.5, RF, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A216 Gr.WCB, API 600 8, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 25284124-8230-SP-000-0007, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.
1
-
-
... More
NOZZLE CHK VALVE,CS, 600,0, MFR. STD., FLGD, B16.5, RF, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A216 Gr.WCB, API 600 8, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.
1
-
-
... More
NOZZLE CHK VALVE,SS, 600,0, MFR. STD., FLGD, B16.5, RTJ, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A351 Gr.CF8C, SS 321H + HF, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, CARBON CONTENT SHALL BE 0.04% OR HIGHER, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.
1
-
-
... More
NOZZLE CHK VALVE,CS (IBR), 600,0, MFR. STD., FLGD, B16.5, RF, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A216 Gr.WCB, API 600 5, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, IBR CERTIFICATE IN FORM IIIC REQUIRED., REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.
1
-
-
... More
NOZZLE CHK VALVE,SS, 150,0, MFR. STD., FLGD, B16.5, RF, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A351 Gr.CF8, API 600 12, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.
1
-
-
... More
NOZZLE CHK VALVE,AS (H2), 900,0, MFR. STD., FLGD, B16.5, RTJ, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A217 Gr.WC6, API 600 5, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 25284124-8230-SP-000-0007, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.
1
-
-
... More
NOZZLE CHK VALVE,SS, 300,0, MFR. STD., FLGD, B16.5, RF, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A351 Gr.CF8, API 600 12, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.
1
-
-
... More
NOZZLE CHK VALVE,AS(NACE+H2), 1500,0, MFR. STD., FLGD, B16.5, RTJ, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A217 Gr.WC6, API 600 12, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, NACE REQ. ACC. TO NACE MR-0103, AND DOC.NO. PDRP-8440-SP-0026, ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 25284124-8230-SP-000-0007, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.
1
-
-
... More
NOZZLE CHK VALVE,AS (H2), 900,0, MFR. STD., FLGD, B16.5, RTJ, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A217 Gr.WC6, API 600 5, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 25284124-8230-SP-000-0007, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.
1
-
-
... More
NOZZLE CHK VALVE,AS (IBR), 600,0, MFR. STD., FLGD, B16.5, RF, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A217 Gr.WC6, API 600 5, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, IBR CERTIFICATE IN FORM IIIC REQUIRED., REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.
2
-
-
... More
NOZZLE CHK VALVE,AS (H2), 900,0, MFR. STD., FLGD, B16.5, RTJ, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A217 Gr.WC6, API 600 5, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 25284124-8230-SP-000-0007, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.
1
-
-
... More
NOZZLE CHK VALVE,CS, 300,0, MFR. STD., FLGD, B16.5, RF, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A216 Gr.WCB, API 600 8, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.
1
-
-
... More
NOZZLE CHK VALVE,SS, 600,0, MFR. STD., FLGD, B16.5, RTJ, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A351 Gr.CF8C, SS 321H + HF, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, CARBON CONTENT SHALL BE 0.04% OR HIGHER, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.
1
-
-
... More
NOZZLE CHK VALVE,SS, 600,0, MFR. STD., FLGD, B16.5, RTJ, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A351 Gr.CF8C, SS 321H + HF, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, CARBON CONTENT SHALL BE 0.04% OR HIGHER, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.
1
-
-
... More
NOZZLE CHK VALVE,AS (H2), 1500,0, MFR. STD., FLGD, B16.5, RTJ, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A217 Gr.WC6, API 600 5, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 25284124-8230-SP-000-0007, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.
1
-
-
... More
NOZZLE CHK VALVE,CS, 150,0, MFR. STD., FLGD, B16.5, RF, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A216 Gr.WCB, API 600 8, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.
1
-
-
... More
NOZZLE CHK VALVE,CS (NACE), 600,0, MFR. STD., FLGD, B16.5, RF, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A216 Gr.WCB, API 600 12, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, NACE REQ. ACC. TO NACE MR-0103, AND DOC.NO. PDRP-8440-SP-0026, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.
2
-
-
... More
NOZZLE CHK VALVE,AS (H2), 1500,0, MFR. STD., FLGD, B16.5, RTJ, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A217 Gr.WC6, API 600 5, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 25284124-8230-SP-000-0007, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.
1
-
-
... More
NOZZLE CHK VALVE,AS (H2), 1500,0, MFR. STD., FLGD, B16.5, RTJ, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A217 Gr.WC6, API 600 5, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 25284124-8230-SP-000-0007, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.
1
-
-
... More
NOZZLE CHK VALVE,CS (NACE), 600,0, MFR. STD., FLGD, B16.5, RF, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A216 Gr.WCB, API 600 12, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, NACE REQ. ACC. TO NACE MR-0103, AND DOC.NO. PDRP-8440-SP-0026, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.
1
-
-
... More
NOZZLE CHK VALVE,CS (NACE), 600,0, MFR. STD., FLGD, B16.5, RF, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A216 Gr.WCB, API 600 12, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, NACE REQ. ACC. TO NACE MR-0103, AND DOC.NO. PDRP-8440-SP-0026, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.
1
-
-
... More
NOZZLE CHK VALVE,CS, 300,0, MFR. STD., FLGD, B16.5, RF, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A216 Gr.WCB, API 600 8, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.
1
-
-
... More
NOZZLE CHK VALVE,CS, 300,0, MFR. STD., FLGD, B16.5, RF, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A216 Gr.WCB, API 600 8, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.
1
-
-
... More
NOZZLE CHK VALVE,CS (H2), 600,0, MFR. STD., FLGD, B16.5, RF, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A216 Gr.WCB, API 600 8, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 25284124-8230-SP-000-0007, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.
1
-
-
... More
NOZZLE CHK VALVE,CS, 600,0, MFR. STD., FLGD, B16.5, RF, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A216 Gr.WCB, API 600 8, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.
1
-
-
... More
NOZZLE CHK VALVE,CS (H2), 600,0, MFR. STD., FLGD, B16.5, RF, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A216 Gr.WCB, API 600 8, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 25284124-8230-SP-000-0007, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.
1
-
-
... More
NOZZLE CHK VALVE,CS (H2), 600,0, MFR. STD., FLGD, B16.5, RF, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A216 Gr.WCB, API 600 8, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 25284124-8230-SP-000-0007, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.
1
-
-
... More
NOZZLE CHK VALVE,CS (H2), 600,0, MFR. STD., FLGD, B16.5, RF, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A216 Gr.WCB, API 600 8, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 25284124-8230-SP-000-0007, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.
1
-
-
... More
NOZZLE CHK VALVE,CS(NACE+H2), 600,0, MFR. STD., FLGD, B16.5, RF, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A216 Gr.WCB, API 600 12, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, NACE REQ. ACC. TO NACE MR-0103, AND DOC.NO. PDRP-8440-SP-0026, ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 25284124-8230-SP-000-0007, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.
1
-
-
... More
NOZZLE CHK VALVE,CS (H2), 600,0, MFR. STD., FLGD, B16.5, RF, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A216 Gr.WCB, API 600 8, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 25284124-8230-SP-000-0007, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.
1
-
-
... More
NOZZLE CHK VALVE,CS (H2), 300,0, MFR. STD., FLGD, B16.5, RF, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A216 Gr.WCB, API 600 8, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 25284124-8230-SP-000-0007, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.
1
-
-
... More
NOZZLE CHK VALVE,LTCS,NACE, 150,0, MFR. STD., FLGD, B16.5, RF, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A352 Gr.LCB, API 600 12, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, NACE REQ. ACC. TO NACE MR-0103, AND DOC.NO. PDRP-8440-SP-0026, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.
1
-
-
... More
NOZZLE CHK VALVE,LTCS,NACE, 300,0, MFR. STD., FLGD, B16.5, RF, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A352 Gr.LCB, API 600 12, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, NACE REQ. ACC. TO NACE MR-0103, AND DOC.NO. PDRP-8440-SP-0026, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.
1
-
-
... More
NOZZLE CHK VALVE,LTCS,NACE, 300,0, MFR. STD., FLGD, B16.5, RF, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A352 Gr.LCB, API 600 12, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, NACE REQ. ACC. TO NACE MR-0103, AND DOC.NO. PDRP-8440-SP-0026, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.
1
-
-
... More
NOZZLE CHK VALVE,CS, 150,0, MFR. STD., FLGD, B16.5, RF, DESIGN NON-SLAM TYPE,, NOZZLE CHK VALVE, INSTALLATION HORIZ. PIPELINE, PR-TEMP. RATING ASME B16.34, LEAKAGE RATE RATE C AS PER, BS EN 12266-1, A216 Gr.WCB, API 600 8, SPRING INCONEL X-750, COLD WORKED & AGE, HARDENED CONDITION, TO MAX HARDNES RC 50, ADD. INFORMATION, VALVE CASTING SHALL BE RADIOGRAPHED, REFER ATTACHMENT-1 FOR ADDITIONAL, REQUIREMENT.