Indian Oil Corporation Limited Tender
Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.
Indian Oil Corporation Limited - IOCL Tender
Machinery and Tools
Eprocure
Opening Date10 Dec 2022
Closing DateCancelled
Tender AmountRefer Documents
Costs
EMD
₹ 74,290Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2022_ERBBS_160211_1Bid Award Id
ViewTender No
SERPL/BBS/TS/2022-23/074Tender Authority
Indian Oil Corporation Limited ViewPurchaser Address
-Website
http://https://www.iocl.com/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Special_Instructions_to_the_Bidders_20220221v1a.pdf
BOQ Items
CU,6CX2.5 mm²,2XWY: LT Cables FRLSH - Copper Cables-1.1 KV, XLPE insulated, extruded PVC type ST-2 inner sheathed, galvanized armour ed, PVC type ST-2 overall sheathed, Stranded, FRLSH, C2, Smoke density40%
260
-
146.02
Power cables LT : OD upto 20 mm: Cable Laying - Laying of all type of cables LT (PVC / XLPE / Armoured/Unarmoured/Power/ Control/ Si gnalling) in trenches, in cable racks, in trays, in protective pipes, poles, columns, in conduits, in panels and on structures etc.; including the supply and installation of all required materials such as fixing clamps, screws, cable straps, tags, etc. as required (other than the supply of the conduits, cables, pipes, cable racks, trays, poles, structures and panels) complete in all respect, i ncluding cost of all labour, tools, consumable materials, etc. and cutting the cables in required lengths as per drawings, specifica tion and directions of Site Engineer / Engineer-in-Charge:
260
-
32.85
FLAME PROOF PUSH BUTTON: Supply of M/s. BALIGA/CEAG-FCG/FLEXPRO make painted flameproof, weatherproof on-off, 20a rated push button with FLP gland suitable for a supply voltage of 415V, 3 ph, 50 C/S, AC as per IS-2148, 1968 IS: 2147 for IP- 55. The supply must be accompanied with approved certificate from CMRS, Dhanbad and CCE, Nagpur, BIS for flameproof ness as per is-2 148 suitable for Div. I gas group I, IIA, IIB area
2
-
6784.83
PUSH BUTTON / CONTROL STATION STAND: Supplying and erection of Push Button Station/Control Station with MS channel grouted with PCC including excavation alignment,erection and connection of Push Button, connection of contro l cable, earthing including supply and fixing of saddles, nuts, bolts etc. and painting wth two coats of bituminous aluminium paint/ synthetic enamel paint over a coat of red oxide primer all complete with labour and materials as per drawing and the direction of En gineer-in- Charge (Push Button will be supplied by Owner free of cost)
2
-
1420.77
Supply installation and commissioning of panel consisting of 2nos soft starter based panel including one incomer (1000A) with ACB
1
-
1215000
Providing end termination of power/control cable including cutting, stripping, providing & fixing lugs, cable insulation, providing & glanding double compression heavy duty FLAME PROOF TYPE brass cable gland conforming to IS-12943 (Dowell's or approved equivalent) , wherever specified, providing aluminium lugs, crimping/soldering, as necessary, restoration of insulation/clamping of cable, tagg ing with aluminium tag,earthing of armour, connection to the equipment terminals etc. all complete with labour and materials as per standard and direction of the Engineer-incharge
8
-
5173.34
Making straight through joints for medium voltage PVC armoured power & control cables (upto 1.1 KV grade) including cutting, stripp ing of cable insulation, including supply of heat shrinkable TUBULAR straight through cable jointing kit of Raychem / CCI / approved equivalent make with ferrules. All complete with labour and materials as per drawings , specifications and directions of Engineer in charge. 3 / 3.5 / 4 x 400 sqmm
4
-
11781.35
Supply and laying of rcc pipe with collers jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement :2 fine s and) for road crossing Pipes are to be laid after ramming and consolidating the ground with bricks, stone chips etc. to avoid any settlement afterwards. Job includes supply of all labor and all materials required and executed as per direc tion of site engineer. 300 mm dia. R.C.C. pipe
50
-
892.91
Earthing with bare 6 SWG GI wire, providing and connecting equipments with earth bus bar including supply and fixing of bare GI wire of following sizes and making connection with equipment by means of GI bolts, nuts, washers, copper lugs etc. all complete with lab our and materials as per direction of Engineer-in-Charge.
300
-
28.89
Cutting road and making good the same including supply of extra quantities of materials I.e. aggregate, moorum screening, red bajri and labour required. Bituminous portion
25
-
3572.12
Supply ,fabricating and installing following sizes of GI cable trays (ladder type) including horizontal and vertical bends, reduce rs, tees, cross members and other accessories as required and duly suspended from the ceiling and / or fix to steel / RCC/PCC column s, beams, or any other structure members with GI suspenders, angles, channels etc. complete as per the direction of Engineer-in-Char ge. Supports to be provided at an interval of 2 m. Length of 3-Mtr.,Width-450 mm with side riser of 100 mm (Complete with Coupler plate & SS bolt nut) Size: 450 x 100 x 3 mm with Cable Tray Cover on GI having Zn uniform coating not less than 120 Microns.
1000
-
1604.47
Supplying, fabricating, errecting,placing & fixing in position MS structural works of the following type using built up sections fo r truss, claddings, bracings, purlins, supporting frames made of joists, tubes, pipes, channels, angles, plates, flats, bars etc. in cluding cutting to required size welding of joints, fixing anchor plates, including bolts, threading, nuts, washers, sleeves etc. in cluding preparation of detailed fabrication drawings & submission to EIC for approval before start of fabrication,complete in all re spects inclusive of cost of all labour, materials, tools tackles etc. as per drawings, specifications, & direction of EIC. (excludin g cost of concrete work) Hot dip galvanised as per IS: 2629 & tested as per IS: 2633 7 IS: 6745) of approved make with quntity of zinc coating not be less th an 9 N/mw of surface area (0.12 mm uniform thickness)
3
-
148734.63
One coat of high build, self priming, rust encapsulating polyamidoamine cured epoxy mastic coating (80 % solid by volume) to a dry f ilm thickness of 100 microns by AIRLESS SPRAY application followed by one coat of Epoxy MIO (80% solid by volume) with minimum 100 microns DFT by AIRLESS SPRAY application, followed by two coats of isocyanate acrylic aliphatic PU coat (50% solid by vol.) with each coat minimum 50 microns DFT by AIRLESS SPRAY application including supply and application of paints, strip coat on all wel d joints / projections, supply of all equipments, tools & tackels, labour etc. as per specifications of manufacturer and directio ns / instruction of the EIC / Site Engineer
50
-
599.46
Mechanical Works
-
-
-
Motor Operated Pumping Unit, Motor Operated pumping unit (Split Casing) Flow :- 650 Kl/Hr Head :- 30 M as per technical specifications
2
-
1132343.99
Dismantling of Piping Aboveground and equipments, Dismantling of Piping Aboveground and equipments_R as per Direction of EIC/Site engineer
3
-
20275.65
Equipment Installation : Motor driven Pumping units Installation, Motor Driven Transfer Pumping Unit Installation: Taking delivery of Motor Driven Pumping units having electrical motor & centrifugal pump and accessories etc,from designated storage location within the pump / terminal station, shifting and placing the equipments on the pre-constructed foundation, levelling, grouting and aligning the equipment, assembling together of all sub-assemblies, auxiliaries, mountings, fittings, interconnecting piping etc., carrying out trial run of motor on no load, coupling the electrical motor with the pump, making final alignment, checking and testing of the complete pumping unit and completing the work in all respects in accordance with the specification, drawings, manufacturer's installation instructions, technical specifications and as per the instruction of the Site Engineer / EIC. Note: Electrical & Instrumentation connections are not included in this item. Transfer Pumping Unit.
3
-
36476.62