Indian Oil Corporation Limited Tender
Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.
Indian Oil Corporation Limited - IOCL Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date29 Jul 2024
Closing Date12 Aug 2024
Tender Amount₹ 13,39,947
Costs
EMD
0Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PDR_179333_1Bid Award Id
ViewTender No
PDO1S24122Tender Authority
Indian Oil Corporation Limited ViewPurchaser Address
-Website
http://https://www.iocl.com/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Bidders_help_Document_for_Preferencial_ Bidding_20230207_v1
Special_Instructions_to_the_Bidders_20230207_version_1a
BOQ Items
CABLE LAYING ON TRAYS / STRUCTURES : Horizontal and vertical laying of different instrument cables (Signal / Power / Control / Alarm / Thermocouple / RTD etc.) of different sizes and types (armoured/ unarmoured) in cable "trays/ wall and steel structures upto any height , fixing of " galvanized clamps and screws for fixing cables on to the trays/ "structures etc., providing aluminium cable tags at both the ends " "of the cable, testing and transportation from stores to site, " "unpacking, straightening, dressing of cable & returning the empty " "drums with unused cable, if any to stores complete with labour " "and materials as per the drawings, specifications and directions " of the engineer-in-charge. NOTE : Cables will be supplied by owner free of cost.
-
-
-
Cable Size: Overall diameter upto 20 mm
5000
158300
31.66
LAYING OF LT POWER/ CONTROL/ TELEPHONE/ INSTRUMENT/ CCTV/ COMPUTER AND OTHER CABLES ON CABLE TRAYS/ STRUCTURES Horizontal and vertical laying of one or more armoured / unarmoured PILCA / PVC insulated and PVC sheathed / XLPE LT power (voltage grade upto 1.1 KV)/ control/ telephone/ instrument/ CCTV/ computer and other cables on cable racks/ wall and steel structures upto any height, fixing of saddles, aluminium strip, number tags ( if required), testing plus transportation from stores to site, unpacking, straightening, dressing of cable, fixing with clams/ cleats as required and returning the empty drum with unused cable, if any, to stores etc. all complete with labour and materials as per the drawings, specifications and directions of the Engineer-in-charge. NOTE: Cables will be supplied by the Owner free of cost.
-
-
-
Overall diameter upto 35 MM
2000
96500
48.25
LAYING OF LT POWER/ CONTROL/ TELEPHONE/ INSTRUMENT/ CCTV/ COMPUTER AND OTHER CABLES IN TRENCHES Horizontal and vertical laying of one or more armoured / unarmoured PILCA / PVC insulated and PVC sheathed / XLPE LT power (voltage grade upto 1.1 KV)/ control/ telephone/ instrument/ CCTV/ computer and other cables of following sizes in pre-excavated cable trench or existing trench / RCC or Hume or Stoneware or Metal pipe / masonry duct, fixing of number tags ( if required), testing plus transportation from stores to site, unpacking, straightening, dressing of cable and returning the empty drum with unused cable, if any, to stores etc. all complete with labour and materials as per the drawings, specifications and directions of the Engineer-in-charge. NOTE: Cables will be supplied by the Owner free of cost.
-
-
-
Overall diameter upto 35 MM
1000
44620
44.62
TEMPORARY CABLE LAYING ON SURFACE Temporary laying and fixing of LT power/control/telephone cables on surface as required including carriage, handling, testing, cutting, sealing, fixing with clamps / cleats etc., transporation of cable from stores to site and returning the empty drum with unused cable, if any, to stores etc. all complete with labour and materials as per the drawing, specification and direction of the Engineer-in-charge. NOTE: 1) Cables will be supplied by the Owner free of cost.
-
-
-
Overall diameter upto 35 MM
5000
116950
23.39
CABLE DISMANTLING / PULL OUT Dismantling/pulling out the LT/HT, PVC/XLPE, power/ control/ telephone/ computer, armoured/ unarmoured cables of various voltage grades/types/ sizes / makes from the trench (upto 1.5 metres deep) / pipes / structures / racks or trays, rolling it into empty cable drums, returning the filled up cable drums to the store/ another site including transportation of empty cable drums from stores to site and filled up cable drums from site to stores/another site, etc. including cutting of cables at joints/ termination, dismantling of clamps etc. all complete with labour and materials as per directions of the Engineer-in-Charge.
-
-
-
Overall diameter upto 35 MM
5000
152500
30.5
GI PIPE LAYING (INCLUDING COST OF PIPE) Providing and laying medium quality, Class-B galvanised steel pipes of Tata / Jindal or approved equivalent make conforming to IS-1239 [Part-I] in underground trenches, on steel, concrete or similar structures including cutting, threading, bending, supply & installation of supports, clamps, small iron structures, spacer, seats, plugs, bush, fittings / fixtures like bends, tees, nipples, reducers etc. all complete as per specification, drawing and direction of Engineer-in-charge. Item includes sealing of pipe ends & joints with bushes and bitumen based fillings and such other miscellaneous works so as to make piping water tight.
-
-
-
25 mm dia
20
4202
210.13
50 mm dia
20
7524
376.2
SUPPLYING AND FIXING OF GI ROUTE MARKER Suppplying cable route marker with 10 cm x 10 cm x 5 mm thick GI plate with inscription thereon, bolted/ welded to 35 mm x 35 mm x 6 mm angle iron, 60cm long and fixing the same in ground as required. Job includes painting with one coat of redoxide and finishing paint.
20
10914
545.73
SUPPLY & FIXING OF PVC CASING / CAPING Providing and fixing following size of PVC casing and caping on surface as required. Note: Only ISI marked caping and casing shall be used.
-
-
-
20 MM X 10 MM
1000
64580
64.58
25 MM X 10 MM
1000
67450
67.45
SUPPLY & FIXING OF RECESSED PVC CONDUIT Supply and fixing of following size of PVC conduit alongwith the accessories in recess including cutting the wall and making good the same in case of recessed, conduit as required: Note: Only ISI marked conduits shall be used.
-
-
-
25 mm
100
10836
108.36
SUPPLY & FIXING OF PVC CONDUIT ON SURFACE Supply and fixing of following size of PVC conduit alongwith the accessories in surface including cutting the wall and making good the same in case of recessed, conduit as required: Note: Only ISI marked conduits shall be used.
-
-
-
25 mm
100
9588
95.88
EXCAVATION OF EARTH FOR CABLE / PIPE LAYING FOR ELECTRICAL WORK Excavation of earth for cable trenches / laying of G.I. pipes for cable work in all types of soils including saturated soil upto a max. depth of 1.5 metres including shoring, strutting and bailing out of water (if necessary), backfilling and compacting in layers not exceeding 20 cm. thick to the finished ground level and disposal and dressing of excess earth within a lead of 50 metres all complete with labour and materials as per standards, drawings, specifications and directions of Engineer-in-charge.
200
63016
315.08
Cutting road and making good the same including supply of extra quantities of materials i.e. aggregate, moorum screening, red bajri and labour required:
-
-
-
Bituminous portion.
3
10880
3626.8
SHIFTING OF PANEL/ MOTOR/ EQUIPMENT Transportation from the store to the site or from worksite to worksite within battery area or within township of panel, motor and any other equipment alongwith all necessory accessories without any damage. All complete with labour, materials, necessary tools/ tackles and shifting vehical/ mode as per the direction of Engineer-in-Charge. Unit shall be read as EACH in place of TON
-
-
-
Small equipment requiring tractor trailer but not requiring crane / hydra etc. (beyond 100 kg.) Unit shall be read as EACH in place of TON
10
14630
1463.07
REMOVAL OF RCC SLAB UPTO 150 MM THICK Removal of RCC slab upto 150 mm thick and of any size placed above the cable trench, handling carefully without any damage of the slab and cable beneath it and keeping it back in position after laying / removing the cable and sealing the same between RCC covers with cement & sand. job complete in all respect with labours and materials and as per direction of engineer-in-charge.
50
4124
82.48
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge:
-
-
-
Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix).
2
3350
1675.09
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work up to plinth level :
-
-
-
1:2:4 (1 cement : 2 coarse sand (Zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources).
2
14383
7191.74
SUPPLY & FIXING OF MISC MOSAIC WIRING ACCESSORIES Supply, fixing and connection of 250 V below given mosaic wiring accessories of M/s MDS or approved equivalent inlcuding supplying and fixing of nuts, bolts, etc. complete with labour and materials as per direction of the Engineer-in-Charge.
-
-
-
RJ 45 UTP category 6 - 2 module information outlet - tool less
300
131214
437.38
OTDR (Optical time-domain reflectometer) Testing of OFC "Optical Time Domain Reflectometer (OTDR) should be calibrated for the index of refraction of the fiber to be tested. Attenuation shall not exceed 0.56dB/kms at 1310 nm and 0.40dB/kms at 1550 nm and no discontinuities greater than 0.1dB over a distance of less than 300 feet shall be allowed. OTDR repots/ traces clearly annotating each splice and the measured loss, shall be submitted to the Engineer-in-Charge for review and approval. The Contractor shall report any discontinuities greater than those specified for the fiber."
20
33900
1695
OFC Cable- OFC Cable- Fusion Splicing Including supply of 1.5 meter SMF/MMF (Single mode/Multimode Optical Fiber) Pigtail "General Requirements:- Each fibres shall be spliced by the fusion method. Splice loss shall not exceed a bi-directional average of 0.10 dB per splice for a complete fiber run or a maximum of 0.15 dB bidirectional averages for any single splice at 1310 and 1550 nanometers. At least one and one-half revolutions of the splice tray of fiber shall be left on each end of fiber after splicing. Splice Materials: At each splice point splice organizer trays/junction box shall be provided to contain and protect the bare fibers and splices. The splice trays shall be layered above the transition/storage compartment and shall be easily slipped into place on two studs and secured with a hold down strap. Each tray shall be made of injection-molded plastic and have a hinged clear plastic cover for maximum fiber protection that allows for visible inspection of the fibers. All splices shall be protected with a heat-shrink sleeve containing protective sleeve and housing. No more than 12 splices shall be placed in one tray unless the engineer approves any changes."
300
110235
367.45
SPLICING CHAMBER
10
106491
10649.12
FIXING OF LIU
15
2248
149.92
FIXING OF WALL MOUNT RACK
15
2248
149.92
LAYING OF HDPE IN TRENCHES/TRAYS
3000
43200
14.4