Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.

Bharat Sanchar Nigam Limited - BSNL Tender

Works
Eprocure
Opening Date6 Dec 2021
Closing Date15 Dec 2021
Tender Amount₹ 5,45,632 
This is an estimated amount, exact amount may vary.
Notes
Download

Summary

Attending Mv/lt Electrical Faults And Repairing Of Ei And Fans And Service Connection Cables Etc. For Various Tes/bts In Bhubaneswar Ba For The Year 2021-22. (zone-ii- Bhubaneswar City And Areas Under Bhubaneswar Sdca).

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Distance above 100 Kms and up to 200 Kms from Bhubaneswar

5

-

-

... More
Replacement of the faulty and burn out MCBs, Isolators etc. by new ones of following ratings MCBs and Isolators ISI marked as per IEC 60947-3 /MCBs 10 kA , C- Curve as per IEC 60947-2 in existing MCBDBs i/c connection testing etc. as required.(Make-Legrand / L&T / Schneider Electric / Siemens/Havells )

-

-

-

... More
63Amps 4 pole Isolator

5

-

-

... More
63Amps 4 pole MCB

10

-

-

... More
63 Amps DP MCB

3

-

-

... More
32Amps 3 pole MCB

3

-

-

... More
40Amps DP Isolator

5

-

-

... More
40Amps DP MCB

5

-

-

... More
6-32A SPMCB

10

-

-

... More
63 Amps 415V HRC Fuse links (L&T/Havells)

12

-

-

... More
100 Amps 415V Porcelain Fuse unit

6

-

-

... More
Replacement of the following burnt out/damaged cable/wires/lugs/sockets etc. by new one of following types, sizes and ratings PVC insulated FR copper conductor single core stranded flexible cable i/c laying / drawing in existing conduit/pipe, connection, testing etc. as required.

-

-

-

... More
25sqmm with copper socketings

10

-

-

... More
16sqmm with copper socketings

10

-

-

... More
10sqmm with copper socketings

20

-

-

20

-

-

... More
4sqmm

30

-

-

... More
1.5sqmm

50

-

-

... More
Replacement of the burnt out cables/wirings by the following sizes PVC insulated & PVC sheathed copper conductor multi core cable i/c fixing/laying on wall/ceiling with C clamps etc. as required.

-

-

-

... More
3 coreX2.5sqmm

20

-

-

... More
4 coreX2.5sqmm

10

-

-

... More
3 coreX4.0 sqmm

10

-

-

... More
Supply of the following sizes PVC insulated & PVC sheathed Aluminium conductor armoured cable 650/1100 V. grade confirming to IS : 7098 (Part-1) 1988 i/c transportation to respective sites etc. as required for replacement of faulty/burnt out cables.

-

-

-

... More
4 core 16 sqmm

100

-

-

... More
4 core 25 sqmm

30

-

-

... More
3.5 core 50sqmm

20

-

-

... More
Replacement of faulty service connection cables by new one of 2 core X4sqmm PVC insulated and PVC sheathed Aluminium conductor weather proof cable etc. as required.

50

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.

-

-

-

... More
Up to 35sqmm

20

-

-

... More
Above 35 sq. mm and up to 95 sq. mm

20

-

-

... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.

-

-

-

... More
Up to 35sqmm

50

-

-

... More
Above 35 sq. mm and up to 95 sq. mm (clamped with 25x3mm MS flat clamp)

50

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size Up to 35sqmm direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.

-

-

-

... More
Up to 35sqmm

20

-

-

... More
Above 35 sq. mm and up to 95 sq. mm (clamped with 25x3mm MS flat clamp)

20

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size Up to 35sqmm in the existing Duct/Air as required.

-

-

-

... More
Up to 35sqmm

100

-

-

... More
Above 35 sq. mm and up to 95 sq. mm (clamped with 25x3mm MS flat clamp)

20

-

-

... More
Replacement of damaged MV cable end terminations with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.

-

-

-

... More
4 X 16 sq. mm (28mm)

10

-

-

... More
4 X 25 sq. mm (28mm)

3

-

-

... More
3½ X 50 sq. mm (35mm)

3

-

-

... More
Replacement of faulty SDFUs/Change over switches by new ones of following ratings after dismantling the old defective ones, fixing, connection & testing etc. as required.

-

-

-

... More
32 Amps 415 volts TPN SDFU with DIN type HRC fuses (open execution type). (Make: L&T FN type, /Havells / L & T) .

2

-

-

... More
63 Amps 415 volts TPN SDFU with DIN type HRC fuses (open execution type). (Make: L&T FN type, /Havells / L & T) .

2

-

-

... More
63 Amps 415 volts TPN SDFU in Sheet steel enclosure with DIN type HRC fuses. (Make: L&T FN type, /Havells / L & T) .

2

-

-

... More
63Amp 4-pole on load change over switch open execution type (Make: HPL Socomec /Havells / L & T) .

2

-

-

... More
63Amp 4-pole on load change over switch in sheet steel enclosure , front handle type (Make: HPL Socomec /Havells / L & T) .

2

-

-

... More
125Amp 4-pole on load change over switch in sheet steel enclosure , front handle type (Make: HPL Socomec /Havells / L & T) .

2

-

-

... More
Replacement of faulty MCCBs by new ones of following ratings after dismantling the old defective ones, fixing, connection & testing etc. as required.

-

-

-

... More
63Amps 36 KA 3 pole 415 volts 50 Hz, with Magnetic Thermal over load release (L&T DN0-100D/Equivalent of Siemens/ABB/Havells)

2

-

-

... More
63Amps 36 KA 4 pole 415 volts 50 Hz, with Magnetic Thermal over load release (L&T DN0-100D/Equivalent of Siemens/ABB/Havells)

2

-

-

... More
100Amps 36 KA 3pole 415 volts 50 Hz, with Magnetic Thermal over load release (L&T DN0-100D/Equivalent of Siemens/ABB/Havells)

2

-

-

... More
100Amps 36 KA 4pole 415 volts 50 Hz, with Magnetic Thermal over load release (L&T DN0-100D/Equivalent of Siemens/ABB/Havells)

2

-

-

... More
Replacement of faulty and damaged FTL fittings by new one of following ratings, 65000K LED Batten suitable for operation on 140 volts to 270 volts AC, 50Hz i/c fixing and connection etc. as required. (Havells /Phillips / Surya / Polycab / Crompton)

-

-

-

... More
10 watt

5

-

-

... More
20 watt

10

-

-

... More
30 watt

5

-

-

... More
12 watt 6500K LED Ceiling Circular

5

-

-

... More
18 watt 6500K LED Ceiling Circular

5

-

-

... More
Polycarbonate Bulk head fitting with 6.5 watt 6000K LED lamp

5

-

-

... More
Supply of the following electrical accessories/components for Electrical Light Fittings i/c testing etc. as required.

-

-

-

... More
36 /40 watt Fluorescent Tube rods

50

-

-

... More
36/40 watt Electronic ballast for Fl. Tube fittings

30

-

-

... More
Starter for Fl. Fittings

50

-

-

... More
9 watt BC LED Lamp

10

-

-

... More
15 watt BC LED Lamp

10

-

-

... More
Angle/batten Holder

10

-

-

... More
Ceiling Rose 3 plate

10

-

-

... More
Replacement of the defective switches/sockets/lamp holders/ call Bells etc. by the new one of following ratings etc. as required. (Make- Anchor/Havells/Cona/ISI)

-

-

-

... More
6 /10 Amps 1 way modular type switch

10

-

-

... More
16/20 Amps 1 way modular type switch

5

-

-

... More
6 /10 Amps 1 way piano type switch

10

-

-

... More
20 Amps 1 way piano type switch

5

-

-

... More
6 /10 Amps 3pin modular type socket

5

-

-

... More
16/5 Amps 6 pin modular type socket

5

-

-

... More
6 Amps 3 pin piano type socket

10

-

-

... More
16 Amps 3 pin piano type socket

5

-

-

... More
Carry out repairing of Electrical Light Fittings by arranging qualified and trained man power and tools, tackles, ladders etc. i/c dismantling of defective/faulty components and fixing of new components i.e chokes, lamps, starters, interconnection wires, lamp holders etc. as required.

50

-

-

... More
Rewinding of 1200mm/1400mm ceiling fan by superior quality super enameled copper conductor i/c heat varnishing, testing etc. as required.

5

-

-

... More
Overhauling of Ceiling Fan i/c dismantling, heat varnishing of windings, greasing of bearings, refitting, testing etc. as required.

5

-

-

... More
Replacement of the defective Capacitors / Fan regulators/ bearings for ceiling fans etc. by the new one of following ratings etc. as required. (Make- Anchor/Havells/Cona/ISI)

-

-

-

... More
Stepped type Electronic Fan Regulator (Switch type)

5

-

-

... More
2.25 mfd 440 volts Capacitor for Ceiling Fan

10

-

-

... More
Bearings for Ceiling fans (6201 & 6202) etc. as required. (Make: SKF/SS)

10

-

-

... More
S/F of MCB protected Socket outlet 4 module with metal box comprising of 01no. 25Amps socket and 01no. 25Amps Plug and 01no. 25Amps "C" series SPMCB for Split AC units i/c connection, testing etc. as required. (Make- Legrand /Havells/HPL/Standard)

3

-

-

... More
Replacement of burn out Sockets/lugs of cables by new ones of following types and sizes i/c dismantling the burnt out portion of cables/wires, crimping/fixing of new sockets/lugs etc. (Dowell's / Comet / Hex Connect well / SS)

-

-

-

... More
For 4X16sqmm Al Conductor Armoured cable

2

-

-

... More
For 3.5/4X25/35sqmm Al Conductor Armoured cable

2

-

-

... More
For 3.5X50/70sqmm Al Conductor Armoured cable

4

-

-

... More
Supply of Hot pressed molded SMC Junction box, hinged double door type of following sizes suitable for application for fixing Electrical controls /switch gears/meters etc. with provision for cable entry/exit from bottom/side , locking arrangements including supply and fixing of 2nos 4 pole stud connectors, interconnections with suitable size single core PVC insulated copper conductor cable with copper sockets/lugs including fixing on existing pole / existing MS/GI angle stands etc. complete as required.

-

-

-

... More
Size not less than 650mmX350mmX250mm (inside dimensions) (Make-Sintex model: SINTEX JB-6535/SS)

2

-

-

... More
Size not less than 400mmX300mmX190mm (inside dimensions) (Make-Sintex model: SINTEX JB-4030/SS)

2

-

-

... More
Making suitable angle base frame made of 40mmX40mmX5mm MS angle for installation of mentioned SMC junction / meter boxes , cutting, welding, fabricating, grouting the same on ground with required PCC work complete as required.

4

-

-

... More
Supply and fixing of SMC Junction box of size 200mm x 140mm x 95mm (inside dimensions) with hinged door type including supply and fixing of 1no. 4 pole stud connector with nuts and bolts etc. as required. (Sintex GSJB2014/SS)

2

-

-

... More
Liaison with the Electricity DISCOMs for taking shutdown of LT/MV lines for checking, testing and replacement of faulty Service connection cable/Energy Meter/ Meter box/Feeder panel etc. and re energisation of power supply after replacement of faulty components as above / removal of faults etc. complete as required.

8

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.