Military Engineer Services Tender
View complete overview of Nagaland MES Tender
Costs
EMD
₹ 86,440Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_MES_623227_1Bid Award Id
ViewTender No
8585/C/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Material & labour for brick work with sub class 'B' bricks(using old size burnt bricks) straight or curved on plan to any radius in half brick thick walls built in CM 1:4 etc complete all as specified and as directed.
10
-
-
M&L Brick work with sub class B bricks(using old size burnt bricks) straight or curved on plan exc 6.00 m mean radious built in CM 1:6 etc complete all as specified and as directed.
4
-
-
S & F second class hardwood weather boarding, clean sawn, plain, 20 mm thick or feather edged 15 mm to 20mm thick and fixed with 30mm laps etc complete all as specified and as directed.
20
-
-
S & F in repairs 0.71 mm dia wire netting of Stainless steel wire of size 12 mm mesh fixed with tinned tack of wire staple for bird proofing etc complete all as specified and as directed.
200
-
-
M & L for plain fillets, square, rectangular or triangular in section clean sawn, secured with nails 2nd class hard wood exc 13 and n.exc 25 sqcm etc complete all as specified and as directed.
50
-
-
Taking down Chowkhat or frames not exceeding 1.5 Sqm each with shutters(Without taking off shutters from the frames etc complete all as specified and as directed.
10
-
-
All as per item No. 09.00 here-in-above but exceeding 1.5 Sqm but not exceeding 4 Sqm each etc complete all as specified and as directed.
5
-
-
Taking down door chowkats with shutter exc 1.5 but not exc 4 sqm each (without taking off shutters from the frame) etc complete all as specified and as directed.
2
-
-
Taking down door shutter exc 1 sqmtr but nex 2 sqmtr each and removing to store etc complete all as specified and as directed.
2
-
-
S&F size of frame 125 x 60mm Pressed steel frames (thickness of MS sheet 1.25 mm)for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete all as specified and as directed.
10
-
-
S&F factory made 30mm thick, flush shutters, solid core construction, with particle board core and plywood face panels etc complete all as specified and as directed.
5
-
-
S&F Powder Coating aluminium colour frame for doors, windows, ventilators and partition etc with one or more rebates including joining cleat for fixing etc complete all as specified and as directed.
50
-
-
S&F Powder Coating aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats,glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc complete all as specified and as directed.
10
-
-
S&F for Powder Coating aluminium window and ventilator shutters, fixed type without sash bar, aluminium section of size 40 x 18 x 1.29mm thick including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc complete all as specified and as directed.
5
-
-
M&L for sheet glass 3mm thick ordinary quality, pin headed type and glazing with oil putty or wooden beads not exceeding 0.5 Sqm in each pane etc complete all as specified and as directed.
10
-
-
S&F mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 18mm, fixed with tinned tacks or galvanized wire staples etc complete all as specified and as directed.
10
-
-
S & F 100 size stainless steel butt hinges etc complete all as specified and as directed.
10
-
-
Supply & Fixing 150 mm Aluminium handles, cast type, anodised etc complete all as specified and as directed.
10
-
-
S & F 200 mm Aluminium, anodised, barrel tower bolts of extruded section and fixed etc complete all as specified and as directed.
5
-
-
S & F 300 mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast-aluminium alloy and fixed etc complete all as specified and as directed.
5
-
-
M&L for preparation of new plastered or un plastered surface of walls including cornices, pilasters etc and applying two coats of cement base paint including primer etc complete all as specified and as directed.
135
-
-
M&L for applying two coats of oil bound distemper on new plastered surfaces of walls including preparation of surface etc complete all as specified and as directed.
200
-
-
M&L for preparation of new surfaces of steel and iron work of any description over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of redoxide primer on new surfaces in any tint etc complete all as specified and as directed.
125
-
-
All as per item No. 26.00 here-in-before but applying two coats of synthetic enamel paint over a coat of pink wood primer on new surfaces etc complete all as specified and as directed.
5
-
-
M&L preparation of old surfaces of walls applying one coats of cement base paint etc complete all as specified and as directed.
110
-
-
M&L for Preparation of old decorated surfaces by washing, scrubbing down, and applying one coat of oil bound distemper on walls etc complete all as specified and as directed.
130
-
-
M&L for preparation of new ceiling surface and tthree coats of white wash on ceiling etc complete all as specified and as directed.
25
-
-
M&L for preparation of wall surface and applying three coats of white wash etc complete all as specified and as directed.
34
-
-
M&L for75 mm thick PCC (1:3:6) type C2 , using 40 mm graded stone aggregate in plinth protection/aprons/path laid to slope of 1:12, finished fair and even without using extra cement with and including all necessary formwork to divide tha area in panels, finishing exposed edges fair or rounding or chamfering where directed and providing 10 mm wide joints throughout thickness of plinth protection duly filled with mastic filling (one part of hot bitumen 85/25 and three part of fine sand by weight) etc complete all as specified and directed.
10
-
-
Demolition Stone slabs and tiles of any description or thickness in floors, aprons etc complete all as specified and as directed.
4.2
-
-
M&L for Virified Ceramic tiles (Light shade) 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.18 sqm but not exc 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles etc laid over and including screed bed of 15 mm thick in CM (1:6) complete all as specified and as directed.
10
-
-
M&L for coloured Non - skid Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over and including 15mm thick CM (1:4) screed bed etc complete all as specified and as directed.
10
-
-
All as per item No. 35.00 here-in-above but on vertical surfaces such as skirting , dado risers to steps over and including 10 mm thick backing coat in CM 1:4 .
10
-
-
M&L for coloured Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of tiles laid over and including 10mm thick CM (1:4) backing coat etc complete all as specified and as directed.
10
-
-
M&L cement concrete type C-2 (1:3:6) (using 40 mm graded stone aggregate) as in surface channels and drains etc complete all as specified and as directed.
1.1
-
-
M&L for Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement incl firms moulds etc complete all as specified and as directed.
20
-
-
Demolition of Cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and etc complete all as specified and as directed.
0.1
-
-
Dismantling wall and ceiling board fibre, pulp insulation etc or insulation boards any thickness including cover fillets etc complete all as specified and as directed.
152
-
-
S & F for 4 mm thick of size 600x600mm HSPC (high pressure Steam Cured) pre-Painted self embossed, textured designer board E-Board Classic to be fixed Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre. fixed in ceiling flat or Sloping etc complete all as specified and as directed.
110
-
-
Taking down cement plaster on brick walls including raking out joints hacking for key, scrubbing down with water etc complete all as specified and as directed.
250
-
-
M&L for rendering 15mm thick in CM (1:6) on fair faces of brick work or concrete surfaces finished fair and even without using extra cement etc complete all as specified and as directed.
209
-
-
M&L for rendering 15 mm thick cement plaster in CM 1:4 on brick work/concrete surfaces finished even and fair with WPC @ 2% by weight of cement content and without using extra cement etc complete all as specified and as directed.(Note:-WPC will be measured and paid separately)
110
-
-
M&L for rendering 5mm thick plaster in CM 1:3 on fair faces of brick or concrete work finished even and smooth without using extra cement as in ceiling etc complete all as specified and as directed.
25
-
-
Material & labour 2nd class hardwood plain, solid straight chowkhats and frames, wrought, framed rebated on the solid,rounded or chamfered, put together with glue pinned at joints etc complete all as specified and as directed.
0.1
-
-
Dismantling Plain corrugated steel sheeting, any gauge, thickness, including, Nanital or similar pattern roof covering etc complete all as specified and as directed.
708
-
-
S&F for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws etc complete all as specified and as directed.
821
-
-
S&F for pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws etc complete all as specified and as directed.
96
-
-
Dismantling wrought iron or mild steel work of any description not otherwise provided for etc complete all as specified and as directed.
0.6
-
-
S&F Rolled sections as in roof truss, purlins including cleats GDE Fe 410-0-or Fe 310-0 etc complete all as specified and as directed.
100
-
-
S&F for 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing complete all as specified and directed.
50
-
-
M&L for Solid PVC Wall Lining consisting of 5mm thick Plain or coloured with wood grains printed PVC sheet inclusive of solvent cement and fixing at site on PVC frame etc complete all as specified and as directed.
92
-
-
S&F 20mm dia Harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc complete all as specified and as directed.
30
-
-
S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment ( Fe 410-W Gde-E- 250 quality-A) etc complete all as specified and as directed.
110
-
-
M&L Polythene film, 50 micron thick, laid on a coat of bitumen primer, @ 0.30 to 0.50 kg per sqm etc complete all as specified and as directed.
60
-
-
M&L for taking down 10mm thick toughness glass, securing and refixing the same after changing the required fitting and fixtures complete all as specified and as directed
9
-
-
M&L 2nd class hard wood (treated with Anti – Termite treatements), clean sawn, in scantling timber frame and fixed with nails etc complete all as specified and as directed.
0.55
-
-
S&L 30mm Think 1st Class Hard Wood Planed one side & edges tongued and grooved or rebated (Teak Wooden Flooring 30mm (Rustic Grade) 92% Red.). Fixing With Screw, Fastener, Fevicol and Finished Water Base Polish etc complete all as specified and as directed.
60
-
-
S&F rubber pad of size 55 x 75mm, 10mm thick etc complete all as specified and as directed.
600
-
-
M&L for preparation of surfaces and applying two coats of water base polishing to wooden flooring etc complete all as specified and as directed.
66
-
-
S&F mild steel bolts, purpose made, with hexagonal or square head one end and screwed the other end to be fitted with washer and one hexagonal or squre nut n exc 15cm long 12mm dia etc complete all as specified and as directed.
20
-
-
S&F mild steel bolts, purpose made, with hexagonal or square head one end and screwed the other end to be fitted with washer and one hexagonal or squre nut exc 30cm long and dia 25mm etc complete all as specified and as directed.
20
-
-
Excavating in post holes (or similar holes) each n exc 0.5 cu. M, getting out, returning, filling in and raming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50m and making good surface in soft/ loose soil etc complete all as specified and as directed.
50
-
-
M&L for Plain Cement concrete type B-2, (1:2:4) (using 40mm graded stone aggregate) as in foundation filling and mass concrete etc complete all as specified and as directed.
6
-
-
S&F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S 1161-1979 grade St.-240 etc complete all as specified and as directed.
1909
-
-
Excavation in trenches n exc 10 sqm on plan, n exc 1.5 m deep and n exc 1.5m wide, getting out in any type of soil etc complete all as specified and as directed.
16.16
-
-
Surface excavation n exc 30 cm deep and averaging 15 cm deep and getting out in hard and dense soil etc complete all as specified and as directed.
82
-
-
M&L for broken stone or boulders Hardcore of gauge exc 63 mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface etc complete all as specified and as directed.
8.2
-
-
M&L Cement concrete in foundations, filling and mass concrete in (1:4:8) type D-2 using 40mm graded stone aggregate etc complete all as specified and as directed.
1
-
-
M&L Cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in sub base 100mm thick etc complete all as specified and as directed.
82
-
-
M&L Cement concrete (1:2:4) type B-2 using 40mm graded stone aggregate as in paving 100mm thick etc complete all as specified and as directed.
82
-
-
S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) includingdistance pieces, cleats etc. conforming Fe-410-W (Gde-E-250) quality -A and painted one shop coat of zinc chromate primer paint (including preparation of surfaces) at contractors workshop before fabrication etc complete all as specified and as directed.
425
-
-
M&L for forming contraction (Dummy) joints 65mm x 10mm wide, filled with sealing compound etc complete all as specified and as directed.
6
-
-
Supply only integral water proofing compound etc complete all as specified and as directed.
1
-
-
S&F 0.63mm plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drips and straight flashing (length and girth as fixed) wih grade of zink coating 275 etc complete all as specified and as directed.
5
-
-
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soils etc complete all as specified and as directed.
10.27
-
-
Removing Excavated soils not exceeding 50 M and depositing where directed at a level not exceeding 1.5 M above the starting point etc complete all as specified and as directed.
22.28
-
-
Supply & install Voltage stabilizer for automatic operation, three phase naturally oil cooled indoor type and designed for input variation between 300 V to 480 V with output voltage stabilized at output voltage range 415 ± 1 % phase to phase, 240V ± 1% phase to neutral and of capacity 25 KVA including necessary suitable foundation work with PCC approved by manufacturer etc complete all as specified and as directed.
1
-
-
Material and labour XLPE insulated, armoured heady duty electric cable with aluminium conductor, 1100 Volts grade, cross sectional area 70 Sqmm 3.5 core etc complete all as specified and as directed.
35
-
-
Material and labour XLPE insulated, armoured heady duty electric cable with aluminium conductor, 1100 Volts grade, cross sectional area 50 Sqmm 3.5 core etc complete all as specified and as directed.
30
-
-
Material and labour XLPE insulated, armoured heady duty electric cable with aluminium conductor, 1100 Volts grade, cross sectional area 35 Sqmm 3.5 core etc complete all as specified and as directed.
31
-
-
M&L for laying of LT UG cable, XLPE insulated, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of 25 sq mm, 4 core including taking down old unsv LT UG cable/ service connection complete all as specified and as directed. NOTE :- (i) Excavation and earth work, sand cushioning, cable protection cover, pipe etc. shall be measured and paid seperately under relevant items.
30
-
-
Materials and labour for sand filling around the cable with approved quality coarse sand for sand cushioning of Under ground cable including spreading and punning down to 23cm thickness complete all as specified and as directed.
4.86
-
-
Materials and labour for brick protection cover to underground cables with sub class ‘B’ over burnt brick of size 23 X 11.5 X 7.5 cm, (locally available best quality), laid dry and flat abutting each other with gaps not exceeding 10mm complete all as specified and as directed.
450
-
-
Supply & laying tubes ' light grade' galvanised, with all fittings, fixed complete to walls, poles, ceilings or laid in floors/ trenches/ road crossing for protection of cables of size 40 mm dia bore including taking out unsv GI tubing complete all as specified and as directed.
6
-
-
Supply, install, test and commission out door type feeder pillar boxes 600mmx600mmx500mm (Bus bar chamber) with aluminium bus bar 200 amps - 04 Nos fixed over epoxy insulators and outer shell made out of 3.15 mm thick MS sheet supported with MS angle section 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform 90 cm above and 45 cm below the ground level, frame factory fabricated with front openable single door ( door hinged with body at 4 places with hinges ) lockable/open able by Keys having chromium plated 19 mm dia fancy lock, “U” type gasket shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, tested at factory approved from CPRI for 35 MVA rupturing capacity at 415 Volts factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:8623/93,etc complete all as specified and as directed.
1
-
-
S&F installation and testing and commissioning of Split type inverter Air conditioner of capacity 2 ton rating 5 star with cordless remote operated on 230 Volt AC supply complete to wall with suitable bracket for indoor outdoor unit and connected with electric suply, testing on full load etc complete all as specified and as directed.
Make : Voltas/Blue star/Godrej/LG
Make:-Voltas,Blue star,LG
2
-
-
Supply and fixing Voltage stablizer for automatic operation single phase indoor type and designed for input variation between 90-300 volts with digital disply out put voltage stablizer at 230 Volts with energy of± 2.5 % and of capacity 5 KVA etc complete all as specified and as directed.
2
-
-
Supply and install vertical pack type Tower Air conditioner units indoor/outdoor complete with cordless remote control and with inbuilt air ioniser and Plasma filter for better indoor air quality with twin rotary compresser three phase units 415 volts 50 Hz of capacity 3.0 TR With eco friendly refrigerent.(MAKE:-VOLTAS/LG/BLUESTAR)a)
Note :- (i) Cutting holes in walls/ Window of any thickness for installation of AC etc, connection and making good the disturbed surface to match with the existing surface after work shall be done and rate is included in above rate .
(iii) Electrical cable required to connect outdoor unit with indoor unit and indoor unit to voltage stabilizer included in above rate.
(ii) copper piping/ drain piping/ insulation material/ tapping included in above rate.
2
-
-
Supply and fix Voltage stabilizer for automatic operation, three phase, naturally oil cooled, indoor type & designed for input variation between 340 V to 480 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second and of capacity 20 KVA etc complete all as specified and as directed.
1
-
-
M&L for Triple pole and earth encolsure with a three pin and earth plug with socket complete suitable for one triple pole MCB complete all as specified and as directed.
2
-
-
S&F MCB triple pole and neutral 415 volts 32 amps, with rupturing capacity 10 KA, 'B' curve type, with over load and short circuit protection etc complete all as specified and as directed.
2
-
-
S&F and testing factory made sheet metal enclosure for MCB DB TPN 4 way 415 volt with double door, IP - 43 protection duly with fixed in wall/ concealed in wall complete and making good disturbed surfaces of wall, floor etc including electric wire connection etc complete all as specified and as directed.
1
-
-
S&F MCB triple pole and neutral 415 volts 63 amps, with rupturing capacity 10 KA, 'B' curve type, with over load and short circuit protection etc complete all as specified and as directed.
1
-
-
S&F MCB triple pole and neutral 415 volts 40 amps, with rupturing capacity 10 KA, 'B' curve type, with over load and short circuit protection etc complete all as specified and as directed.
2
-
-
M&L for sub main wiring with Four runs of 6.00 Sq mm and one run of 6.00 Sq mm for earth wire with multi standard copper conductors, 1100 volts grade, drawn through and including PVC double locked Casing & caping including complete all as specified and as directed.
NOTE:- Four runs of 6.00 Sq mm + one run of 6.00 Sq mm and one run of PVC casing & capping and its accessories of suitable size shall be measured as one unit length.
Make:- Finolex/Havells/RR Kabel Make of caping/casing :- Prestoplast/Finolex/supreme
40
-
-
M&L for sub main wiring with two runs of 4.00 Sq mm and one run of 4.00 Sq mm for earth wire with multi standard copper conductors, 1100 volts grade, drawn through and including PVC double locked Casing & caping including complete all as specified and as directed. NOTE:- two runs of 4.00 Sq mm + one run of 4.00 Sq mm and one run of PVC casing & capping and its accessories of suitable size shall be measured as one unit length .Make:- Finolex/Havells/RR Kabel Make of caping/casing :- Prestoplast/Finolex/supreme
41
-
-
M&L for metal clad AC socket point single pole and neutral enclosure with a tow pin and earth plug and socket complete with one single pole MCB SP 20 Amps complete all as specified and as directed.
2
-
-
M&L for MCB Distribution board double door type SPN 4 way with 200 amps rated bus bar, sheet steel, powder painted, with neutral link & earth bar etc. and fixing MCBs of various rating capacity complete all as specified and as directed.
1
-
-
Supply and fixing MCB SPN 32 Amp rating 240V, 10KA 'C' curve miniature circuit Breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
2
-
-
M&L for earthing with galvanised steel earth plate 600x600x6 mm thick burried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level connected to galvanized iron 32 x 6 mm strip earth as earthing lead by means of bolts nuts check-nuts and washers of galvanized iron or steel besides welding at all joints as shown in drawings and including excavation and earth work GI pipe light grade 15mm bore for protection of GI wire from earth electrol to earth dolly including earth earth test point of galvanized iron or steel of size 75x75x25 mm supplying and laying char coal dust common salt PCC 1:2:4 type B-1 chamner and MS angle frame 40 x 40 x 3 mm and RCC cover 40 mm thick (1;2:4) type B-1 using 20 mm graded stone aggregate reinforced with 6 mm dia round bars @ 75 mm C/C both ways with MS handle 12 mm dia GI funnel and wire mesh 20 mm dia GI pipe light grade for watering all as shown in drawing and connected to earth test point including testing complete all as specified and directed.
1
-
-
Material & Labour for earthing with galvanised steel earth plate electrode of size 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead wire 4 mm by means of bolts, nuts check nuts and washers of galvanised iron or steel as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified orindicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1, RCC (1:1.5:3) type A1 precast cover (54cmx54cmx5cm) duly reinforced with including 8 mm dia TMT bar @ 150mm c/c both ways, one lifting handle made of 8mm dia TMT bar, embeded in precast cover slab, funnel, 20mm dia GI medium grade watering pipe, 15mm dia GI light grade earth lead protection pipe, chorcoal and common salt in alternatee layer complete all as specified and directed by Engr-in-Charge.
2
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements