Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2019_MES_302842_4Bid Award Id
ViewTender No
8156/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
One 3 pin socket outlet 5 Amps on the independent board
2
-
-
... More
All as per item No- 01 here-in-before but with 2.5 Sq mm for 3 pin 15 Amps socket point controlled by one switch on independent board and 2.5 Sq mm copper conductor green in colour as earth continuity conductor connected to common earth dolly complete all as specified and directed by Engr-in-Charge Make : RR Kable/Havells/Finolex/Richa
4
-
-
... More
M&L for Switch piano flush type single pole, one way 5A complete all as specified and directed by Engr-in-Charge
Make : Anchor/SSK/Plaza
57
-
-
... More
M&L for Socket outlet, 2 in 1, 5 pin 5A flush type complete all as specified and directed by Engr-in-Charge
Make:- Plaza/SSK/Hager
3
-
-
... More
M&L for Switch socket combination 2 in 1, 5A/16A, 5 in 1 flush type complete all as specified and directed by Engr-in-Charge
Make : Anchor/SSK/Plaza
6
-
-
... More
M&L for 20W LED, 4', Wall mounted LED batten, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver.etc with all accessories internally pre-wired and fixing the same on and including two Nos PVC blocks and connecting up with flexible copper cable of size 0.75 Sq mm 3 core from ceiling rose to the light fitting complete all as specified and directed by Engr-in-Charge
Make : Havells Cat No LHFYBYPNIA1W022 Regal (batten) & LHDLEFXD5LR020(LED Tube) or equivalent in Bajaj/Philips
2
-
-
... More
M&L for LED 1x20W building Security light fitting, drawn through including GI bracket of 25mm bore light grade bent to shape and fixed on wall with metal fastners 2 Nos 10mm dia incl drilling holes as required and connecting up with flexible copper cable of size 0.75 Sq mm 3 core from ceiling rose to the light fitting complete all as specified and directed by Engr-in-Charge
Make:-Havells Cat Pt No LHETBXU7PA6S020 or equivalent in Bajaj/Philips
1
-
-
... More
M&L for commercial RO plant 200 LPH with suitable cap water pump , filters , High pressure pump , membrane , electrical control panel including flow meters , pressure switch and gauges pipe fittings etc complete all as specified and directed by Engr-in-Charge
Make: Kent/Eureka forbes/Aqua Guard.
1
-
-
... More
M&L for rotational moulded polythylene water storage tanks of cap 1000 Ltr cylindrical vertical with closed top hoisted and fixed in position complete all as specified and directed by Engr-in-Charge
Make: Sintex/Polywell/Polycon/Rotax/Kilkamal
3
-
-
... More
M&L for PVC water container 20 Ltr cap for storage of treated water complete all as specified and directed by Engr-in-Charge
Make: Sintex/Polywell/Polycon/Rotax/Nilkamal
40
-
-
... More
M&L for GI tubes medium grade 25mm with all fittings and fixed to wall or laid in floor complete all as specified and directed by Engr-in-Charge
Make:- Jindal/TATA/Prakash surya
23
-
-
... More
All as per item No 12 above but 20mm dia for internal plumbing work complete all as specified and directed by Engr-in-Charge
Make:- Jindal/TATA/Prakash surya
10
-
-
... More
Cutting existing steel tubing 50mm dia for addition or alteration and screwing existing steel tubing to form connector in positioncomplete all as specified and directed by Engr-in-Charge.
1
-
-
... More
M&L for gun metal globe or gate valves 25mm dia with iron wheel head screwed both ends for iron pipe complete all as specified and directed by Engr-in-Charge
Make: Leader/Zoloto/L&T
1
-
-
... More
M&L for ball brass valves high pressure 20mm with polythene float and flynut complete screwed for iron pipe complete all as specified and directed by Engr-in-Charge
Make: Leader/Zoloto/RAMCO/L&T
1
-
-
... More
Bib taps cast copper alloy fancy type 20mm dia with crutch or butterfly handle screwed down for iron pipes complete all as specified and directed by Engr-in-Charge
Make: Leader/Zoloto/L&T.
1
-
-
... More
M&L for MCB Distribution board double door type SPN 4way, sheet steel, powder painted, with bus bar neutral link & earth bar etc. and fixing MCBs of various rating capacity complete all as specified and directed by Engr-in-Charge
Make:- Legrand/ABB/Siemens
1
-
-
... More
S&F for 15 mm bore GI Water tubing medium grade laid in floors or fixed in wall with GI fittings complete all as specified and directed by Engr-in-Charge
Make : TATA/ Jindal/ Surya
70
-
-
... More
S&F for 20 mm bore GI Water tubing medium grade laid in floors or fixed in wall with GI fittingscomplete all as specified and directed by Engr-in-Charge
Make : TATA/ Jindal/ Surya
53
-
-
... More
S&F 15 MM bore stop cock, cast copper alloy fancy type, chromium plated, screwed dowmn high pressure with crutch or butter fly handle, screwed both ends for iron pipe or for unious and fixed complete all as specified and directed by Engr-in-Charge.
7
-
-
... More
S&F 15 MM bore bib tap fancy type type chromium plated with long shank complete all as specified and directed by Engr-in-Charge.
4
-
-
... More
S&F PVC connections 15 mm size with PTMT nuts of length 600 mm complete all as specified and directed by Engr-in-Charge
8
-
-
... More
M&L for ceiling rose 3 terminal PVC/Polycarbonate isolated body complete all as specified and directed by Engr-in-Charge
Make : Anchor/SSK/Plaza
54
-
-
... More
M&L for sub main wiring with two runs of 4 Sq mm and one run of 4 Sq mm for earth wire with multi standard copper conductors, 1100 volts grade, drawn through and including PVC double locked Casing & caping including complete all as specified and directed by Engr-in-Charge
NOTE:- two runs of 4 Sq mm + one run of 4 Sq mm and one run of PVC casing & capping and its accessories of suitable size shall be measured as one unit length .
Make : RR Kable/Havells/Finolex/Richa
205
-
-
... More
S&F Exhaust fan metallic 300 mm sweep single phase 50 Hz AC, air flow rate of 900Cmh, and 1350 RPM including fixing on wall with suitale fastners, making holes of suitable size and making good distrubed surfaces area complete all as specified and directed by Engr-in-Charge
Make : Havells/Bajai/CG
20
-
-
... More
S&F Electric Storage water heater of 25 Ltrs capacity comlpete single phase 240 Volts complete all as specified and directed by Engr-in-Charge
Make : Havells/Bajai/CG/Usha
4
-
-
... More
S&F ceiling fan 1200 mm sweep single phase 50 Hz AC, including all fixing arrangements such as fan hook, fan clamp,nut, bolts etc complete all as specified and directed by Engr-in-Charge
Make : Havells/Bajai/CG/Usha
46
-
-
... More
M&L for MCB Distribution board double door type SPN 12 way, sheet steel, powder painted, with bus bar neutral link & earth bar etc. and fixing MCBs of various rating capacity including taking down old unsv MCB DBs complete all as specified and directed by Engr-in-Charge
Make:- Legrand Cat No 507622 or equivalent in ABB/Siemens
1
-
-
... More
M&L for MCB SPN 40 Amps, 230 volts, 50 Hz suitable for fixing in MCB DB 'C' series incl taking down old unsv MCB complete all as specified and directed by Engr-in-Charge
Make:- Legrand Cat No 408617 or equivalent in ABB/Siemens
9
-
-
... More
M&L for MCB SP 5-32 Amps, 230 volts, 50 Hz suitable for fixing in MCB DB 'C' series incl taking down old unsv MCB complete all as specified and directed by Engr-in-Charge
Make:- Legrand Cat No 408587 to 408595 or equivalent in ABB/Siemens
12
-
-
... More
Supply and erect Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.00 metres long), as per IS-2713 including painting with one coat of black bituminous paint through out internally and externally up to ground level and remaining external surfaces of poles shall be painted with two coats of aluminium paint over a coat of red oxide, zinc chrome primer including dismantling the old steel tubular pole, complete all as specified and directed by Engr-in-Charge
(Note: Excavation & earthwork , PCC foundation & coping shall be measured & paid separately)
2
-
-
... More
M&L for LED flood light 45 watt capacity with high luminious efficacy made up of pressure die cast aluminium housing with hight power LED as lighting source and lens embedded PC cover having Top Opening seperate driver compartment with IP 66 protection and impact resistance of IK07 with 10 KV Built in surge protection device including 1 x GI bracket made of light grade GI pipe 32 mm bore (1.5 mtrs length) and 40mm medium grade GI pipe (length nxe. 300mm) duly selded with steel pole at suitable height with provision of two Nos (Nut & bolts) for securing of GI bracket 32 mm bore. making electrical connection with flexible aluminium cable from line conductor to light fitting complete all as specified and directed by Engr-in-Charge.
Make : Havells/ Bajaj/ Crompton
2
-
-
... More
M&L for laying of LT UG cable, XLPE insulated, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of 16 sq mm, 2 core complete all as specified and directed by Engr-in-Charge
NOTE :- (i) Excavation and earth work, sand cushioning, cable protection cover, pipe etc. shall be measured and paid seperately under relevant items. Havells/Finolex/Polycab/RR Kabel
28
-
-
... More
M&L for laying of LT UG cable, XLPE insulated, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of 10 sq mm, 2 core complete all as specified and directed by Engr-in-Charge
NOTE :- (i) Excavation and earth work, sand cushioning, cable protection cover, pipe etc. shall be measured and paid seperately under relevant items.
80
-
-
... More
M&L PVC insulated armoured heavey duty electric cable with aluminiun conductor 1100 volts grade cross sectional area 35 Sqmm 4 core complete all as specified and directed by Engr-in-Charge Make : Polycab / Hevells/Finolex or equivelent
50
-
-
... More
M&L for laying of LT UG cable, XLPE insulated, galvanised steel strip or wire armoured heavy duty electric cable with aluminium conductor 1100 Volts grade cross sectional area of 25 Sqmm 3.5 Core including connection to existing DB complete all as specified and directed by Engr-in-Charge
Make : Havells/Polycab/Finolex
70
-
-
... More
M&L for cable connection to street light of 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed cable flat or circular 4 Sqmm twin core complete all as specified and directed by Engr-in-Charge
15
-
-
... More
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth and getting out in soft/ loose soil complete all as specified and directed by Engr-in-Charge
51.5
-
-
... More
Returning filling in trenches including spreading leveling watering and well ramming in layers not exceeding 25 cm thick all complete all as specified and directed by Engr-in-Charge
29.1
-
-
... More
Removing of excavated material not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all complete all as specified and directed by Engr-in-Charge
22.4
-
-
... More
M&L for spread fine river sand in trenches complete all as specified and directed by Engr-in-Charge NOTE: For measurement purpose, punned down thickness shall only be taken.
19.3
-
-
... More
M&L for laying brick sub class 'B' old size burnt bricks for cable protection of size 230mmx115mmx75mm complete all as specified and directed by Engr-in-Charge
2346
-
-
... More
M&L for Cement concrete in foundations, filling and mass, bed concrete for base plate, Type D2 (1:4:8) 40 mm grade aggregate complete all as specified and directed by Engr-in-Charge
0.16
-
-
... More
M&L for Cement concrete in foundations, filling and mass Type C2 (1:3:6) 40 mm grade aggregate complete all as specified and directed by Engr-in-Charge
1.26
-
-
... More
M&L for Cement concrete for coping above ground level, filling and mass Type B2 (1:2:4) 40 mm grade aggregate complete all as specified and directed by Engr-in-Charge
0.18
-
-
... More
M&L for replacement of HDPE pipes fixed to wall ceiling or floor of 25 mm bore complete all as specified and directed by Engr-in-Charge
11
-
-
... More
M&L for PVC pole junction boxes with inbuilt aluminuim bus bar (02 Nos) of suitable size fitted over bus bar insulator and fixing to pole complete all as specified and directed by Engr-in-Charge
Make :Sintex/Hensel/C&S.
2
-
-
... More
Supply,installation and testing Air conditioner split type 1.5 TR capacity 5 BEE rating invertor type wall mounted air cooled electric driven single phase 50 Hz AC supply.with cordless remote unit complete all as specified and directed by Engr-in-Charge
Make:- Voltas/Samsung/Bluestar
1
-
-
... More
M&L for servo voltage stablizer 5 KVA capacity single phase air cooled unbalance type microprocessor bassed digital disply in powder coated encloser with cooper winding ,wiring and termination and input correction range 180 Volts to 270 Volts and output voltage stablized at 230 volts +/-5% with minimum correction speed of 8 volts per secound as per IS-9815(Part I)/1994 with provision of low and high voltage cutoff relays complete all as specified and directed by Engr-in-Charge
Make Sinetrac/V Guard/Microtek
1
-
-
... More
M&L for single pole & neutral sheet metal encloser with a two pin and earth plug and socket complete with one single pole MCB of 20 Amp rating complete all as specified and directed by Engr-in-Charge
Make :- Legrand Cat No 507811 or equivalent in ABB/Siemens
4
-
-
... More
M&L for sub main wiring with 2x 2.5 Sq mm and 1x 2.5 Sq mm for earth wire with multi standard copper conductors FRLSH, 1100 volts grade, drawn through and including PVC casing caping all accessories fixed to wall, ceiling, floors etc. including making good the disturbed surfaces complete all as specified and directed by Engr-in-Charge
Make :- Havells/Finolex/Polycab
75
-
-
... More
Supply,installation and testing Air conditioner Window type 1.5 TR capacity 3 BEE rating invertor type wall mounted air cooled electric driven single phase 50 Hz AC supply.with cordless remote unit complete all as specified and directed by Engr-in-Charge
Make:- Voltas/Samsung/Bluestar
2
-
-
... More
M&L for servo voltage stablizer 4 KVA capacity single phase air cooled unbalance type microprocessor bassed digital disply in powder coated encloser with cooper winding ,wiring and termination and input correction range 175 Volts to 260 Volts and output voltage stablized at 230 volts +/-5% with minimum correction speed of 8 volts per secound as per IS-9815(Part I)/1994 with provision of low and high voltage cutoff relays complete all as specified and directed by Engr-in-Charge
Make:- Sinetrac /V Guard/Microtek
2
-
-
... More
M&L for cutting opening through brick wall made in cement mortar for door window and other openings or enlarging existing opening cutting out defective brick work for under pinning incl fixing and providing and removing shoring cleaning and stacking bricks removing surplus bricks hard core etc to store and rubbish not exc 50 m complete all as specified and directed by Engr-in-Charge
0.25
-
-
... More
S & F Ventilating fan metallic type of 450 mm sweep complete with louvres,1400 rpm single phase 240 Volt complete all as specified and directed by Engr-in-Charge
Make Havells, code No- Ventil Air-DX
2
-
-
... More
M&L for PVC rectangular block for mounting DBs etc of size 350x300x50 mm deep with 3 mm thick plastic plastic laminated sheet cover complete all as specified and directed by Engr-in-Charge
4
-
-
... More
M&L for 15 mm dia for downrod hanging the ceiling fan including drilling,holes complete all as specified and directed by Engr-in-Charge
7
-
-
... More
M&L for fan hook mad out of MS flat 50x6mm suitable to fix at truss complete as per sit requirement complete all as specified and directed by Engr-in-Charge,
16
-
-
... More
Supply and install single phase pure sine wave Inverter of 4 KVA or nearest cap with output AC Voltage 230 Volt 50 Hz including overload protection, surge protection, power saver, over charge protection and inclusive of 4 Nos external DC battries 130 AH maint free on wooden platformcomplete all as specified and directed by Engr-in-Charge
Make of UPS : Sukam/Luminous/Microtex.Make of bty: Exide/Amaron/TATA
1
-
-
... More
M&L for sub main wiring with two runs of 6 Sq mm and one run of 4.0 Sq mm for earth wire with multi standard copper conductors, 1100 volts grade, drawn through and including PVC double locked Casing & caping including complete all as specified and as directed. NOTE:- two runs of 6 Sq mm + one run of 4.0 Sq mm and one run of PVC casing & capping and its accessories of suitable size shall be measured as one unit length .Make : RR Kable/Havells/Finolex/Richa
23
-
-
... More
M&L for point wiring 2.5 Sqmm for 3 pin 15 Amps switch socket point on independent board along with one run of 2.5 Sqmm copper conductor green in colour as earth continuity conductor connected to earth dolly complete all as specified and directed by Engr-in-Charge
2
-
-
... More
M&L for MCB Distribution board double door type SPN 2 way, sheet steel, powder painted, with bus bar neutral link & earth bar etc. and fixing MCBs of various rating capacity complete all as specified and directed by Engr-in-Charge
Make:- Legrand Cat No 507620 or equivalent in ABB/Siemens
6
-
-
... More
S&F Isolator four pole 63 Amps, 415 Volt complete all as specified and directed by Engr-in-Charge
Make: Legrand , Hevells or equivelent
1
-
-
... More
M&L sheet metal enclosure for DB triple pole and nutral 4 way double doorcomplete all as specified and directed by Engr-in-Charge.
Make : Legrand/ Hevells or equivelent
1
-
-
... More
M&L for boring of hole under road , pavements, hardstanding by trenchless technoogy by using ultrasounding techniques and necessary machine for laying of cable including 50mm dia galvanized iron pipe light grade complete all as specified and directed by Engr-in-Charge
5
-
-
... More
M&L for boring of hole under road with mechanical arrangement suitable for insertion 100mm dia without disturbing the top surface of the road for passing the UG electric cable across the road complete all as specified and directed by Engr-in-Charge
6
-
-
... More
M&L for GI Tubing light grade 80mm bore under road crossing/on pole for protection of cable complete all as specified and directed by Engr-in-Charge
Make : Jindal/Tata/Nezone
6
-
-
... More
M&L Tube light grade galvanised with all fittings and and fixed complete to walls and ceiling or laid in floors of size 50 mm dia complete all as specified and directed by Engr-in-Charge.
Make : Jindal/ TATA/ Nezone
10
-
-
... More
Supply and fixing as in replacement for 2x2 surface mounting with clip LED luminarie 42w after mounting white poweder coated CRCA housing with high power LED's plane front frame with translucent cover fixed to the housing including LED lamp ,other accessories and necessary electric connection complete all as specified and directed by Engr-in-Charge
make ;HAVELLS PLUTO Neo PANEL series cat no LHEWEJP7P7L1W042 or equivalent approved make of Philips /Bajaj/Surya Roshni Ltd/WIPRO/Crompton.
20
-
-
... More
Supply and installation front Loading Washing Machine of capacity 15 Kg, electrically Heated, made out of stainless steel complete all as specified and directed by Engr-in-Charge
1
-
-
... More
Supply and installation hydro extractor of capacity - 15 kg, self balancing, rubber buffer type, foot brake type complete all as specified and directed by Engr-in-Charge
1
-
-
... More
Supply and installation Tumbler Dryer of capacity - 15 kg Electrically heated complete all as specified and directed by Engr-in-Charge
1
-
-
... More
Supply and fix Flat Bed Press, Head & bed Size- (1500x750) mm Electrically Heated complete all as specified and directed by Engr-in-Charge
1
-
-
... More
Taking down LT UG cable/ service connection of any size and M&L for laying of LT UG cable, XLPE insulated, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of 50 sq mm, 3.5 core complete all as specified and directed by Engr-in-Charge
Make : RR Kable/ Havells/ Richa NOTE :- (i) Excavation and earth work, sand cushioning, cable protection cover, pipe etc. shall be measured and paid seperately under relevant items
45
-
-
... More
Supply, installation, testing and commissioning of cubical type LT panel board indoor type manufactured by a CPR1 approved factory, made of MS angle iron 40 mm x 40 mm x 6 mm frame work and CRCA steel sheet of 3.15mm thick, totally enclosed dust & vermin proof, single door shutter in front side with necessary locking arrangement duly powder coated of approved shade over one coat of red oxide primer both internally and externally including grouting on PCC platform made out of PCC 1:3:6, all round the panel board with suitable size of busbar. The size of panel boards shall be suitable for housing the following accessories:-
INCOMING
(a) MCCB 4 pole, 160 Amps, 415 volts 25 kA-01 No
(b) Phase indicator lamp RYB-01 No
(c) Digital Voltmeter, 0-500V with selector switch-01No
(d) Digital Ammeter with selector switch & CT coil-01 Set
OUTGOING
(a) MCCB 3 pole, 63 Amps, 415 volt 16 kA-04Nos
(b) MCB 3 pole, 40 Amps, 230 volt 16 kA-02 Nos
1
-
-
... More
M&L for Rotational moulded polyethylene water storage tanks capacity 1000 ltr (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed by Engr-in-Charge
1
-
-
... More
M&L for Gun-metal, gate valves 40 mm with iron wheel head, screwed both ends for GI Pipe complete all as specified and directed by Engr-in-Charge
1
-
-
... More
M&L for Ball brass valves 40 mm high pressure with polythene float and flynut complete screwed for GI Pipe complete all as specified and directed by Engr-in-Charge
1
-
-
... More
M&L for Tubes medium grade, 40mm galvanised with all fittings laid in trenches complete all as specified and directed by Engr-in-Charge
28
-
-
... More
Supply, installation, RO Plant 8 Ltr capacity (single phase), having approx storage of 08 Ltr including all accessories complete all as specified and directed by Engr-in-Charge
Make : Bluestar/ Voltas/ Usha
2
-
-
... More
Supply, installation, testing and commissioning of water cooler fully stainless steel water cooled with UV less power consumption eco friendly refrigent 80 Ltr water storage faucets, electric driven single phase of capacity 40/80 ltr complete all as specified and directed by Engr-in-Charge
Make : Blue star/ Voltas/ Usha
2
-
-
... More
M&L for earthing complete with galvanized steel earth plate electrode of size 600x600x6mm thick buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of the earth plate not less than 1.5 mtr below normal ground level connected to galvanised earth lead wire 4 mm dia as earth lead connectd by means of bolts, nuts, washers and check nuts all as shown in electrical plate No 3 of MES SSR Part-I, including testing on completion complete all as specified and directed by Engr-in-Charge. NOTE:- (i) The unit rate shall also included for earth work in hard/ dense soil, PCC (1:3:6) type C1, CI cover 10 mm thick, funnel with GI watering pipe 20mm dia Medium grade, GI protection pipe light grade 15mm dia and wire mesh complete in addition to item No 1 (a) to (e) of preamble (notes) under sub heading earthing, specified on Sl Page No 389 of MES SSR Part-II. (ii) Earthing lead and GI protection pipe beyond 7.5m will be measured and paid separately. (iii) Test points shall be made of GI strip 32x6 mm bridge type mounted on insulators, where ever applicable.