Military Engineer Services Tender

View complete overview of Nagaland MES Tender

Military Engineer Services - MES Tender

Works
Healthcare and Medicine
Eprocure
Opening Date8 Apr 2024
Closing Date13 May 2024
Tender Amount₹ 8,10,00,000 
Notes
Download

Costs

Summary

Provn Of Dental Units At Rangapahar Mil Stn

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Lumpsum price worked out by the bidder/ tenderer for INTERNAL WATER SUPPLY as listed in Schedule 'A' Part-III.

1

-

151710.23

... More
Lumpsum price worked out by the bidder/ tenderer for INTERNAL ELECTRIFICATION as listed in Schedule 'A' Part-IV.

1

-

435782.05

... More
Lumpsum price worked out by the bidder/ tenderer for DEMOLITION/DISMANTLING as listed in Schedule 'A' Part-V.

1

-

33789.44

... More
Lumpsum price worked out by the bidder/ tenderer for TELEPHONE/INTERCOM as listed in Schedule 'A' Part-VI.

1

-

17137.26

... More
Lumpsum price worked out by the bidder/ tenderer for LIGHTNING PROTECTION as listed in Schedule 'A' Part-VII.

1

-

80064.8

... More
Lumpsum price worked out by the bidder/ tenderer for ROAD, PATH, CULVERT & HARDSTANDING as listed in Schedule 'A' Part-VIII.

1

-

640361.59

... More
Lumpsum price worked out by the bidder/ tenderer for EXTERNAL WATER SUPPLY as listed in Schedule 'A' Part-IX.

1

-

65824

... More
Lumpsum price worked out by the bidder/ tenderer for EXTERNAL ELECTRIFICATION as listed in Schedule 'A' Part-X.

1

-

683207.49

... More
Lumpsum price worked out by the bidder/ tenderer for SEWAGE DISPOSAL as listed in Schedule 'A' Part-XI.

1

-

173340.25

... More
Lumpsum price worked out by the bidder/ tenderer for AREA DRAINAGE as listed in Schedule 'A' Part-XII.

1

-

254699.1

... More
Lumpsum price worked out by the bidder/ tenderer for RETAINING WALL as listed in Schedule 'A' Part-XIII.

1

-

4974558.48

... More
Lumpsum price worked out by the bidder/ tenderer for COMPOUND WALL, FENCING & STEEL GATE as listed in Schedule 'A' Part-XIV.

1

-

657013.86

... More
Sch 'A' Sec-XV (Miscellaneous Items) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 siginifies this fact only.

-

-

-

... More
Supply and fix modular telephone/computer socket (RJ-11) with MS box, including inner and outer plate complete all as specified and directed.

12

-

-

... More
Material & Labour for Earthing with Galvanised Earth Plate Electrode 600x600x6.0mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with and including Galvanised Earth Strip of size 32x6.0mm by means of Bolts, Nuts, Check nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar with GI 40mm bore (dia) Light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc. 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, PGI Funnel with GI Watering Pipe 20mm bore (dia) Medium grade including necessary Excavation in Soft/Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion complete all as per specified and as directed.

24

-

-

... More
Supply and fix electric water heater, storage type steel body with OEM standard inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated alongwith 15 Amp top plug complete with all accessories such as safety valve, thermostate, NRV, PVC Hot & Cold connection pipe complete all as specified and directed.

13

-

-

... More
Supply and fix electric desert cooler run on single phase 230 Volt,50 Hz with water storage 55 Ltr, minimum air flow capacity 4000 cum, PVC plastic body heavy duty complete with all accessories all as directed.

7

-

-

... More
Supply, fix, installation, testing and commissioning of Split type inverter Air conditioner of capacity 1.5 ton rating 5 star having minimum ISEER value 5.0 with cordless remote operated on 230 Volt AC supply complete fixed on wall with suitable bracket for indoor and outdoor unit and connected with electric suply, testing on full load complete all as specified and directed.

5

-

-

... More
Supply, fix, installation, testing and commissioning of Split type inverter Air conditioner of capacity 2.0 ton rating 5 star having minimum ISEER value 5.0 with cordless remote operated on 230 Volt AC supply complete fixed on wall with suitable bracket for indoor outdoor unit and connected with electric suply, testing on full load complete all as specified and directed.

16

-

-

... More
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 150 V to 280 V with output voltage stabilized at 230 Volt with accuracy of +/- 2.5% and of cap 8 Amps (2.0 KVA) complete all as specified and directed.

5

-

-

... More
Supply and fix Voltage stabilizer suitable for Inverter AC of capacity between 1.5 TR to 2.0 TR for automatic operation, single phase naturally air cooled indoor type wall mounted & designed for input variation between 170 V to 270 V AC with output voltage stabilized at 230 V with accuracy of +/- 2.5% and of cap 15 Amps (4.0 KVA) complete all as specified and directed.

16

-

-

... More
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 135 V to 280 V with output voltage stabilized at 230 V with accuracy of +/- 2.5% and of cap 4 Amps ( 1.0 KVA) complete all as specified and directed.

2

-

-

... More
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 135 V to 280 V with output voltage stabilized at 230 V with accuracy of +/- 2.5% and of cap 2 Amps (0.5 KVA) complete all as specified and directed.

2

-

-

... More
Supply and installed Water Cooler Electric driven (single phase), having approx storage Capacity of 80 litres and nominal cooling capacity of 40 litres per hour driven on energy efficient compressor complete all as specified and directed.

2

-

-

... More
Installation and testing and commissioning of Refrigerator single door run on digital inverter technology with latest specification or features of capacity 190 Ltrs single door with 5 star rated complete all as specified and directed.

2

-

-

... More
Material and labour for Preparation of road surfaces and applying thermoplastic reflective paint in marking of minimum 2.5mm thick single coat as in center line and edge line road marking of 150/100mm width using thermoplastic paint (Hot application) white/yellow by indigenous modern propelled road marking machine as directed including all ingredients such as blinder, glass beads Titanium dioxide calcium carbonate inter fillers, thermoplastic requirement for glass beads shall be the table No. 800.4 of MOST specification including spraying of glass beads etc all as per manufacture instructions and as directed

10

-

-

... More
Material and labour for cutting of DI pipe 100mm dia and insertion of CI Tee equal of size 80mm x 100mm x 100mm including fitting and all jointing materials complete all as specified and directed.

1

-

-

... More
Supply & Fix 80mm bore sluice valve (operation-cap) both side flanged, ISI marked (IS No 14846-2000 class PN-1.6) having cast iron body, cast iron hand wheel, non rising type with brass spindle, cheek nuts and sliding gate type body including testing against any leakages complete all as specified and as directed.

1

-

-

... More
M&L for construction of brick masonry valve pit of size 1200 X 1200 X 1200 mm (internal dimension) one brick thick wall in CM 1:4 on 100mm thick PCC 1:4:8 type D-2 (40mm graded aggregate) as in foundation, and 15mm thick rendering in cement mortar (1:4) internally, externally up to 15cm below GL, providing valve pit cover made of 3mm thick MS sheet/plate, welded including provision of hinges, handle and locking arrangement including 40 X 40 X 6mm angle iron frame fixed on top of valve pit by means of hold fast 150mm long, embedded in PCC block 1:2:4 type B-1 (20mm graded aggregate) of size 230 X 200 X 100mm, including two coats of anti-corrosive paint over a coat of red oxide zinc Chrome primer and necessary earth work in soft/loose soil complete all as specified & directed.

1

-

-

... More
Materials and labour for laying brick sub class 'B' old size burnt bricks for cable protection of size 230mmx115mmx75mm complete all as specified and as directed.

2435

-

-

... More
Supply, installation, testing and commissioning floor mounted transformer of capacity 160 KVA step down, outdoor type, 3 Phase, 50 Hz, AC oil immersed, air naturally cooled (ONAN type), EEL 2 rated with external cooling tubes/radiators, double wound core type, copper wound having voltage ratio 11 KV/433 V corresponding to principal tapping, Delta connected primary winding (HV side) and star connected on secondary winding (LV side) in accordance with vector group DYN -11 with neutral brought out on LV side and, constant output so as to alter/vary secondary voltage complete and conforming to IS-1180, of amendment for 2021, Maximum loses of transformer shall be energy efficiency level 2 as per IS-1180 : 2021, Temperature rise in oil 40°C and windings 45°C, Having percentage of impedence not more than 4.5 % complete with all standard fittings and accesssories, gauges, first filling of transformer oil etc complete all as specified and comprising with the following fittings and accessories :- (a) Externally hand operated off-circuit Tap Switch with position indicator and locking device. (b) Conservator with oil gauge, filling hole with plug & drain hole with plug.

1

-

-

... More
Sr Item No. 15.18 (Contd/…) (c) Under carriage with four plain rollers (d) Oil filling hole cum air release plug - 01 No (e) Drain valve cum sampling valve-01 No (f) Filter valve with plug - 01 No (g) Rating Plate & Diagram Plate - 01 No (h) Lifting lugs for Transformer - 02 Nos (j) Lifting lugs for lid -02 Nos (k) Earthing terminals - 02 Nos (l) Thermometer pocket - 01 No (m) Silica gel breather - 01 No Note : (i) The contractor shall provide BEE certified Transformer with the latest star rating offered by the Manufacturer. (ii) The transformer shall be tested in factory premises before despatch by the representative of Accepting Officer. (iii) The quoted rate shall also deemed to be included for transformer platform of size 2500 x 2500 x 1000 mm with PCC 1:4:8 type D2 foundation and brickwork all around in CM 1:6 including plastering, white washing complete all as specified and directed.

-

-

-

... More
Materials and labour for lightning arrester non-linear resister type conforming to IS-3070 (Part-III)-1993 complete, line discharge class-3, nominal discharge current 10 KA (peak), 12 KV rated system voltage peak value high current impulse on 4/10 micro sec, wave shape 65 KA (peak) assy suitable for 11 KV, long duration discharge class-II with insulation level not less than 28/75 KV and mounted on hot dip galvanised steel structure including all clamps, nuts, bolts and washers & connecting to earth complete on pole structure all as specified and directed.

2

-

-

... More
Supply and fixing triple pole mechanically operated air break isolator (GOD), vertical mounting, rotating type, mounted on insulator and steel frame with operating mechanism worked from ground level complete in all respect such as gun metal moving contacts and spring loaded gun metal fixed jaws, knife copper jumper strip etc, suitable for 11000 Volts grade, 50 Hz with 9 insulator of rating upto 200 Amps complete all as specified and as directed.

2

-

-

... More
Supply, install, testing and commissioning of main LT Panel board, TPN 415 volts, 50 HZ out door kiosk type of size 1.5m X 0.6m X 1m mounted on MS angle 50X50 mm 6 mm thick framework CPRI approved factory made, double door dust, vermin and weather proof IP-65, fabricated out of CRCA sheet not less than 3.15 mm thick with 2mm thick for internal compartment duly powder coated fixed on angle iron pedestal made out suitable size with cable chamber for individual feeders for incomming and outgoing connentions, one set of LED indicator lamp RYB with switch and fuse and the panel board shall be provided with proper ventillation including suitable size of cable alley copper bus bar suitable for carrying of current of 600 Amps with suitable connections from MCCB out going to main bus bar shall be carried out with TPN aluminium bus bars of suitable rating and connections from main bus bar to out going MCCBs (intake point) will be carried out with TPN bus bar as per MCCB rating duly insulated and colour coded heat shrinkable sleeve and shall be rigidly mounted on suitable size of bridge insulator including necessary PCC foundation of minimum 0.35 m height positioned and fixed with suitable nut, bolts, washers etc to the MC pedestal all as specified and directed comprising of the following:- incoming and outgoing feeders: Main Panel No 01

1

-

-

... More
Sr. Item No. 15.21(Contd/…) INCOMMING (a) MCCB 4 pole 315 Amps, 415 volt 50 hz 50 KA Ics=100%Icu, Adjustable overload setting (incoming)-01 No (b) LT bus bar for 3 phase 4 wire 600 Amps copper incl CTs of suitable cap -01 Set (c) 3Ph Multifunction Meter, Model B, class 1, 5A with Relay (d) LED type indicator lamp R-Y-B - 1 Set OUTGOING (a) MCCB 4 pole 250 Amps, 415 volt 50 hz 25 KA Ics=100% Icu, Fixed mag setting -01 No (b) MCCB 4 pole 63 Amps, 415 volt 50 hz 25 KA Ics=100% Icu, Fixed mag setting -01 No

-

-

-

... More
Supply, install, testing and commissioning of LT Panel board, TPN 415 volts, 50 HZ Out door kiosk type of size 1.0m x 0.6m x 1 m mounted on MS angle 50 x 50 mm 6 mm thick framework, CPRI approved factory made, double door dust, vermin and weather proof IP-65, fabricated out of CRCA sheet not less than 3.15 mm thick with 2mm thick for internal compartment duly powder coated fixed on angle iron pedestal made out suitable size with cable chamber for individual feeders for incomming and outgoing connentions, one set of LED indicator lamp RYB with switch and fuse and the panel board shall be provided with proper ventillation including suitable size of cable alley copper bus bar suitable for carrying of current of 400 Amps with suitable connections from MCCB out going to main bus bar shall be carried out with TPN aluminium bus bars of suitable rating and connections from main bus bar to out going MCCBs (intake point) will be carried out with TPN bus bar as per MCCB rating duly insulated and colour coded heat shrinkable sleeve and shall be rigidly mounted on suitable size of bridge insulator including necessary PCC foundation of minimum 0.35 m height positioned and fixed with suitable nut, bolts, washers etc to the MC pedestal all as specified and directed comprising of the following: incoming and outgoing feeders:(Bldg Panel)

1

-

-

... More
Sr Item No.15.22(Contd/....) INCOMMING (a) MCCB 4 pole 250 Amps, 415 volt 50 hz 25 KA Ics=100% Icu, Fixed mag setting -01 No (b) LT bus bar 3 phase 4 wire 400 Amps copper incl CTs of suitable cap -01 Set (c) 3Ph Multifunction Meter, Model B, class 1, 5A with Relay (d) LED type indicator lamp R-Y-B - Set OUTGOING (a) MCCB 4 pole 100 Amps, 415 volt 50 hz 25 KA Ics=100% Icu, Fixed mag setting-02 Nos (b) MCB SPN 40 Amps 10 KA-01 Nos

-

-

-

... More
Supply and fix PVC pole junction box of size 155 x 210 x 92 mm, IP 66/69 with 4 pole connectors, PVC cable gland (02 nos). Steel binding or holding kit, nut bolts etc suitable as street light control box complete all as specified and directed.

6

-

-

... More
Materials and labour for cutting existing road/cement concret/bituminous road of size not less than 50mm for laying of GI/CI pipe & makng good to the disturbed surfaces by providing PCC or same material after laying of pipe line and returning filling of soil complete all as specified and as directed.

6

-

-

... More
Supply, Installing, testing and commissioning DG set 160 KVA, six cylinder diesel engine, developing 178.8BHP @ 1500 RPM, Engine will be driven generating set, fully wired 415 volts, +/- 1.5%, 3 phase 4 wire 50 HZ, +/- 0.5% 0.80 PF of capacity 160 KVA, 128KW having continous rating at 1500 RPM, brushless self excited and suitable capacity diesel Engine to run rated KVA alternator as specified above all as per OEM standards & specifications turbo charged water cooled complete under NTP condition with provision for 10% overload for 1hr on 12hr running and common base plate frame engine standard instrumental panel, self exciting and self regulating control panel with accessories, self starter 12 volts with battery 180 AH , 12 volts -01 Nos system with battery charging unit SCR type and battery cable leads , exhaust pipe with cladding by asbestos rope, sound proof canopy including Retrofit device alongwith all required parts/accessories for mounting complete as per latest CPCB norms II etc. Diesel engine set as per IS 10001 and alternator as per IS -13364 with inbuilt electronic speed governer with micro processor based AMF control panel with floor mounted fuel tank not less than 12 hours running capacity including necessary anti vibration pads including standard control panel as recommended by the manufacturer .

1

-

-

... More
Sr. Item No. 15.25(Contd/.....) (a) The diesel engine comprising of following:- (i) Starter motor (ii) OEM standard fuel pump with Electronic Governor (iii) Dry type air cleaner (iv) Residential Silencer (v) First fill of Lube oil (vi) Lube oil filter (Replaceable element type) (vii) Fuel oil filter (Spin on type) (viii) Battery charging alternator (b) GEN SET CONTROLLER Following indication/LCD display shall be available in the Digital Gen Set controller:- (i) Lube oil pressure (ii) Battery voltge (iii) Engine RPM (iv) Fuel level in the day tank (v) Engine Running hours indication (vi) AC Current

-

-

-

... More
Sr. Item No. 15.25(Contd/.....) (vii) AC Voltage (viii) AC Frequency (ix) AC Power metering (x) Suitable CTs for dispalying the electrical parameters safety alarms required in the Digital Gen set controller. (xi) High engine tempreture (xii) Low lube oil pressure (xiii) Low radiator water level (xiv) Low fuel level (xv) Battery high voltage (xvi) Under/over speed safety trips required in the Digital Gen set controller. (xvii) High engine temperature (xviii) Low lube oil. (c) ALTERNATOR : Make Alternator, suitable to deliver rated output at 1500RPM, 380-440V 0.8 PF (lag), 50 Hz, three phase. In SPDP enclosure, self-excited & Self-regulated, Brushless. The alternator conforms to IS: 4722/BS EN 60034-1 & will suitable for tropical condition. Full load efficiency of the alternator offered should be above 90% class of insulation shall be H and temperature rise also limited to class H Enclosure shall confirm to IP23.

-

-

-

... More
Sr. Item No. 15.25(Contd/.....) (d) AUTOMATIC MAINS FAILURE (AMF) CONTROL PANEL: Factory made cubical type floor mounted LT panel board, outdoor kiosk type made out of MS angle not less than 25 x 2 x 5 mm, and 3.15 mm thick MS CRCA sheet, front opening type, protection class IP-65, dust , weather proof and vermin prooof duly powder coated after seven tank process, with electolytic grade copper bus bar of 400 Amps capacity for three phase and neutral wiring of adequate size PVC insulated multi standard copper conductor cable etc and also consisting of following:- (i) MCCB 415 Volts, 250 Amps, rating 4 pole 25 KA rupturing capacity, microprocessor based release for incoming supply overload, short circuit and earth fault protection- 02 (incoming from commercial and stand by supply) (ii) Ammeter 0-500 Amps, 96x96 mm square dial with selector switch 3 way -01 set (iii) Voltmeter 0-500 Amps, 96x96 mm square dial flush type ISI marked with rotary selector switch 3 way-01 set. (iv) Phase indicator lamps (R-Y-B) - 01 set (v) Frequency meter digital type 45 to 55 Hz-01 No (vi) KWH meter 3 phase unbalanced load 1200 Amps capacity incl CT coil-1 Set (vii) 4 pole 415 Volt Power contactor of suitable capacity (02 Nos) with auxiliary contacts. (viii) All standard relays, circuits and protection required for automatic operation of Gen Set. (ix) Battery Charger (PSMB based). (e) Base Frame: Suitable to couple above Engine & Alternator made from steel sheet metal. (f) Fuel Tank: 08 Hrs capacity, with inlet & outlet arrangement, air vent & drain plug arrangement. (g) Battery: 12 V 180 AH

-

-

-

... More
Sr. Item No. 15.25(Contd/.....) (h) Technical Specification of acoustic enclosure construction : Following are some technical features of Acoustic Enclosure :- (i) The enclosure is modular in construction. (ii) Base frame is made of sheet metal (iii) Durable industrial locking system is provided on doors. (iv) Doors are gasketed with high quality EDPN gasket. (j) Corrosion Resistance :- To make the enclosure weather proof :- (i) All sheet metal parts/components are hot dipped in seven tanks process, pre-treated and passivity. (ii) Sheet metal components are painted with P.P base power. (iii) Base frame is epoxy coated. (iv) Specially designed Residential Silencer is provded. (k) Acoustic Insulation : (i) Sound proofing of the enclosure done with quality Foam confirming of IS : 8183. (ii) Acoustic form shall be fire retarded and fire resistant. (iii) Attenuates are provided to control sound at entry and exit to and from the container. (iv) Specially designed Residentil Silencer is provided. (l) Ventilation and air circulation : Exhaust pipe is throughly insulated by covering it with glass wool and further gladded in Enclosure. (m) Electrical : Neutral Body earthing points at the sides of enclosure are isolated through Dough Moulded compound.

-

-

-

... More
Sr. Item No. 15.25(Contd/.....) (n) Safeties : Emergency push button to stop the DG Set from outside, Lub oil level, Lub oul pressure, Fuel level indicator, Coolant level, Canopy temperature, High engine temperature. Note : (i) Design/drawing/BOM of the DG set showing the dimension is to be obtained from the OEM/Auth supplier & is to be got approved from GE before placing final order to the manufacture. (ii) The cost of servicing including minor repairs/replacement such as topping up to coolent, engine /Lub diesel as well as Lub oil filters including periodical checking of the complete DG sets for the complete defects liability period and as when required is deemed to be included in the quoted rates. (iii) Any thing missed out in the technical specification but technically required for efficient working of DG sets in deemed to be included in the quoted rates. (iv) The quoted rates shall be deemed to be inclusive of first fill of engine oil & final successful acceptance test. (v) The quoted rate shall be deemed to be inclusive of 12 + 1 Hrs continous test run upto 110% load for one hour aty site as specified in the PS, in presence of rep of Accepting Officer all testing arrangements/ equipment, resistive load including POL shall be made available by the contractor.

-

-

-

... More
Material & Labour for RCC septic tank conventional type for 150 users design to carry sewage and sludge water constructed with RCC M-30 (Design Mix) including excavation in any type of soil earthwork, returning, filling in and removal of soil upto not exceeding 50m and as shown in TD drawing No. CESZ/2020/STD-02 sheet 1/2 & 2/2 and complete all as specified and directed.

1

-

-

... More
M & L for soakage well of size 3.0 m dia and 3.0 m effective depth including intercepting chamber and screen chamber, including excavation in any type of soil earthwork, returning, filling in and removal of soil upto not exceeding 50m and as shown in TD drawing No. CESZ/2020/TD-45, sheet 1/2 & 2/2 complete all as specified and directed.

1

-

-

... More
Supply, laying and testing of 160 mm nominal diameter High density polyethylene pipes (HDPE) of pressure rating PN4 as per IS : 14333 : 1996 for sewage line in any length, laid in trenches complete all as specified and as directed.

60

-

-

... More
Material & Labour for Construction of Steel gate 6.0m wide & 2.1m height with RCC pillar including excavation in any type of soil earthwork, returning, filling in and removal of soil upto not exceeding 50m and as shown in TD drawing No. CESZ/2017/TD-034, sheet 1/3 & 3/3 complete all as specified and directed.

2

-

-

... More
Material & Labour for Concealed Point wiring with 1.5 Sq. mm (nominal cross sectional area) PVC insulated and un-sheathed single core FRLSH copper cable 1100 volts grade with multi-stranded copper conductor in and including PVC rigid concealed conduit and conduit accessories alongwith continuous earth wire 1.5 Sq mm PVC insulated and un-sheathed single core FRLSH cable 1100 volts grade with multi-stranded copper conductor and connected to common earth dolly, with and including 1.6 mm thick cadmium plated sunk MS pressed steel terminal boxes with 3 mm thick plastic laminated sheet cover fixed with brass screws complete for one light/fan/bell/exhaust point controlled by one way switch.

335

-

-

... More
Material & Labour for Concealed Point wiring with 1.5 Sq. mm (nominal cross sectional area) PVC insulated and un-sheathed single core FRLSH copper cable 1100 volts grade with multi-stranded copper conductor in and including PVC rigid concealed conduit and conduit accessories alongwith continuous earth wire 1.5 Sq mm PVC insulated and un-sheathed single core FRLSH cable 1100 volts grade with multi-stranded copper conductor and connected to common earth dolly, with and including 1.6 mm thick cadmium plated sunk MS pressed steel terminal boxes with 3 mm thick plastic laminated sheet cover fixed with brass screws complete for one light point controlled by two way switch.

8

-

-

... More
Material & Labour for Concealed Point wiring with 1.5 Sq. mm (nominal cross sectional area) PVC insulated and un-sheathed single core FRLSH copper cable 1100 volts grade with multi-stranded copper conductor in and including PVC rigid concealed conduit and conduit accessories alongwith continuous earth wire 1.5 Sq mm PVC insulated and un-sheathed single core FRLSH cable 1100 volts grade with multi-stranded copper conductor and connected to common earth dolly, with and including 1.6 mm thick cadmium plated sunk MS pressed steel terminal boxes with 3 mm thick plastic laminated sheet cover fixed with brass screws complete for one socket outlet point 6 Amp on independent board.

92

-

-

... More
Material & Labour for Concealed Point wiring with 4 Sq. mm (nominal area) PVC insulated and un-sheathed single core FRLSH copper cable 1100 volts grade with multi-stranded copper conductor in and including PVC rigid concealed conduit and conduit accessories alongwith continuous earth wire 4 Sq mm PVC insulated and un-sheathed single core FRLSH cable 1100 volts grade with multi-stranded copper conductor and connected to common earth dolly, with and including 1.6 mm thick cadmium plated sunk MS pressed steel terminal boxes with 3 mm thick plastic laminated sheet cover fixed with brass screws complete for one16 Amps socket outlet on independent board.

62

-

-

... More
Supply and fix Piano switch single pole two way flush type 6 Amps, 230 volts, complete all as specified and directed.

16

-

-

... More
Material & Labour for Sub main wiring with two runs of single core FRLSH PVC insulated and unsheathed multistranded, copper conductor cable of size 1.5 Sq mm (nominal area), 1100 volts grade drawn through and including adequate size Steel conduit and accessories (IS-694 marked in PVC conduit) and fittings and one run of 1.5 Sq mm single core FRLSH multistranded copper conductor cable as earth continuity conductor. NOTES :- (a) Two runs of copper conductor, one run of earth wire and one run of conduit shall be measured as one run length.

24

-

-

... More
Material & Labour for Sub main wiring with two runs of single core FRLSH PVC insulated and unsheathed multistranded, copper conductor cable of size 1.5 Sq mm (nominal area), 1100 volts grade drawn through and including adequate size PVC conduit and accessories (IS-694 marked in PVC conduit) and fittings and one run of 1.5 Sq mm single core FRLSH multistranded copper conductor cable as earth continuity conductor. NOTES :- (a) Two runs of copper conductor, one run of earth wire and one run of conduit shall be measured as one run length.

98

-

-

... More
Material & Labour for Sub main wiring with two runs of single core FRLSH PVC insulated and unsheathed multistranded, copper conductor cable of size 4 Sq mm (nominal area), 1100 volts grade drawn through and including adequate size PVC conduit and accessories (IS-694 marked in PVC conduit) and fittings and one run of 4 Sq mm single core FRLSH multistranded copper conductor cable as earth continuity conductor. NOTES :- (a) Two runs of copper conductor, one run of earth wire and one run of conduit shall be measured as one run length.

252

-

-

... More
Material & Labour for Sub main wiring with four runs of single core FRLSH PVC insulated and unsheathed multistranded, copper conductor cable of size 4 Sq mm (nominal area), 1100 volts grade drawn through and including adequate size PVC conduit and accessories (IS-694 marked in PVC conduit) and fittings and one run of 4 Sq mm single core FRLSH multistranded copper conductor cable as earth continuity conductor. NOTES :- (a) Four runs of copper conductor, one run of earth wire and one run of conduit shall be measured as one run length.

48

-

-

... More
Sub main wiring with two runs of single core FRLSH PVC insulated and unsheathed multistranded, copper conductor cable of size 6 Sq mm (nominal area), 1100 volts grade drawn through and including adequate size PVC concealed conduit and accessories (IS-694 marked in PVC conduit) and fittings and one run of 6 Sq mm single core FRLSH multistranded copper conductor cable as earth continuity conductor. NOTES :- (a) Two runs of copper conductor, one run of earth wire and one run of conduit shall be measured as one run length.

248

-

-

... More
Sub main wiring with Four runs of single core FRLSH PVC insulated and unsheathed multistranded, copper conductor cable of size 10 Sq mm (nominal area), 1100 volts grade drawn through and including adequate size PVC concealed conduit and accessories (IS-694 marked in PVC conduit) and fittings and one run of 10 Sq mm single core FRLSH multistranded copper conductor cable as earth continuity conductor. NOTES :- (a) Four runs of copper conductor, one run of earth wire and one run of conduit shall be measured as one run length.

50

-

-

... More
Supply and fix epoxy powder coated Distribution Board VTPN 4way, 12 module 415 volt vertical type with provision as Incomer MCCB of 200 Amps 4 pole including terminals and outgoing MCBs with common bus-bar at incoming end of outgoing MCBs grouted/ flush to wall complete all as specified and directed

1

-

-

... More
Supply and fix Blank Plate for MCB DB of required size complete all as specified and directed

5

-

-

... More
Supply and fix MCCB 4 pole, 415 V, 200 Amps 36 KA including terminals capacity with adjustable thermal and magnetic release all as specified and directed.

1

-

-

... More
Supply and fix flame proof lighting distribution panel SPN 4 way incoming MCB 2 Pole, 16 Amp -01 No, outgoing MCB 1 pole 6 Amps -02 Nos with complete internal busbar & wiring upto terminals all as specified and directed.

1

-

-

... More
Supply and fix Energy saving ceiling molunted LED light fitting, 36 watt, size 2'X 2' feet 230 volts, Decorative ultra slim linear LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack. with electronic driver and high lumen output, 2.5 KV voltage surge protection, PF 0.98, THD 10% suitable for surface/pendant mounting complete with all accessories including and connecting of with twin core of PVC insulated 0.75 Sqmm copper conductor cable all as specified and directed.

73

-

-

... More
Supply and fix Energy saving ceiling molunted LED light fitting, 1 x15 watt, round shape 230 volts, Decorative ultra slim linear LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack. with electronic driver and high lumen output, 2.5 KV voltage surge protection, PF 0.98, THD 10% suitable for surface/pendant mounting complete with all accessories including and connecting of with twin core of PVC insulated 0.75 Sqmm copper conductor cable all as specified and directed.

9

-

-

... More
Supply and fix LED batten with inbuilt driver made out of high quality aluminum extruded housing and aluminium heat sink for mounting LEDs, mercury free and decorative end caps with maximum power consuption 20 watts with min system luminius efficiency lumen/watt100, CCT not less than 6500 K and CRI , operating voltage of 140-270 volts AC , PF0.90,2.5 KV surge protection and current THD 15% complete and including all other stranded accessories as per manufacturer instruction, internally pre wired including connecting up with twin core copper conductor flexible wire/cable complete all as specified

161

-

-

... More
Supply and fix LED batten with inbuilt driver made out of high quality aluminum extruded housing and aluminium heat sink for mounting LEDs, mercury free and decorative end caps with maximum power consuption 10 watts with min system luminius efficiency lumen/watt100, CCT not less than 6500 K and CRI , operating voltage of 140-270 volts AC , PF0.90,2.5 KV surge protection and current THD 15% complete and including all other stranded accessories as per manufacturer instruction, internally pre wired including connecting up with twin core copper conductor flexible wire/cable complete all as specified

15

-

-

... More
Supply and fix LED Security / street light fittings 25 watt wall mounting type extruded metal/ aluminium body and electronic LED driver, etc with all accessories internal prewired & including connecting up with 2 core flexible copper conductor cable with suitable size complete all as specified and directed.

21

-

-

... More
Fabricated, supply & fix bracket made of GI pipe 25mm dia 0.9 m long & 2 set of clamps made out of 30X5mm MS flat & fixed with anchor bolt suitble for 25 W security light fitting on wall complete all as specified and directed.

21

-

-

... More
Supply & Laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminum conductor served with an inner sheathed of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 6 sqmm nominal cross section in service connections including house service bracket (hook type) complete with 3.0 m long GI pipe 40mm dia med grade two nos 90 degree bends MS hook and stay or guy complete all as specified directed

85

-

-

... More
Supply & Fix ceiling mounted motion sensor for automatic light on/off range 8 meter, 3 wire with neutral, adjustable time delay 5 sec 30 min all as specified and as directed

19

-

-

... More
Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5m below ground level connetced with galvanised wire of 4mm dia by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 15mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke dust and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed.

7

-

-

... More
Supplying and laying of 40 mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors/trenches including special fittings like CPVC Brass fittings (Brass elbow, Brass Tee, Male threaded brass adaptor, Female threaded brass adaptor) complete all as specified and directed.

30

-

-

... More
Supplying and laying of 32 mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors/trenches including special fittings like CPVC Brass fittings (Brass elbow, Brass Tee, Male threaded brass adaptor, Female threaded brass adaptor) complete all as specified and directed.

130

-

-

... More
Supplying and laying of 20 mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors/trenches including special fittings like CPVC Brass fittings (Brass elbow, Brass Tee, Male threaded brass adaptor, Female threaded brass adaptor) complete all as specified and directed.

250

-

-

... More
Supply & fix cromium plated health faucet suitable for 15 mm bore pipe with 1.2m long flexible tube and wall hook including making connections complete all as specified and directed.

12

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.