Repair Maint Cleaning Of Sewage Line Septic Tank Soakage Well In Ne Zone At Rms
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_662094_1Bid Award Id
ViewTender No
8760/C/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Demolition of brick work built in cement mortar or cement lime mortar including all quoins, arches etc complete all as specified and as directed.
41.92
-
-
Demolition of reinforced cement concrete in ground floors and pavings n.exc 15 cm thick above or below ground level etc complete all as specified and as directed.
7.5
-
-
Supply & fix DWCPE 180 (OD)/150 (ID)mm diameter pipes laid in trenches etc complete all as specified and as directed.
410
-
-
M&L for PCC (1:3:6) type C-2 (using 40mm grade stone aggregate) as in bed to 180 mm dia DWCPE/SWR /PVC pipes including packing under and haunching against the sides of pipes after they are laid and tested etc complete all as specified and as directed.
410
-
-
Supply & fix 110mm dia PVC (SWR) pipes single/double socketed in any length with rubber ring joints, laid in trenches or in floors and jointed etc complete all as specified and as directed.
195
-
-
M&L for PCC (1:3:6) type C-2 (using 40mm grade stone aggregate) as in bed to 110/100 mm dia SGSW /PVC pipes including packing under and haunching against the sides of pipes after they are laid and tested etc complete all as specified and as directed.
195
-
-
M & L for PCC (1:2:4) type B1 (using 20mm graded stone aggregate) as in for coping, haunching and the similar work weathering slightly rounded or chamfered edges and throating including formwork etc complete all as specified and as directed.
2.9
-
-
Taking down cement plaster and raking out joints, hacking for key, scrubbing down with water built in cement mortar etc complete all as specified and as directed.
150
-
-
Supply & fix 110mm dia PVC (SWR) pipes single/double socketed in any length with rubber ring joints, fixed to walls etc complete all as specified and as directed.
145
-
-
Supply & fix 75 mm dia PVC (SWR) pipes single/double socketed in any length with rubber ring joints, fixed to walls etc complete all as specified and as directed.
60
-
-
S & F PVC (SWR) bends any radius 110 mm dia etc complete all as specified and as directed.
60
-
-
S & F PVC (SWR) bends any radius 75 mm dia etc complete all as specified and as directed.
40
-
-
S & F PVC (SWR) Single T Equal & unequal any radius 110 mm dia etc complete all as specified and as directed.
40
-
-
S & F PVC (SWR) Single T Equal & unequal any radius 75 mm dia etc complete all as specified and as directed.
10
-
-
S & F 75mm dia PVC (SWR) vent cowl etc complete all as specified and as directed.
15
-
-
S & F 110mm dia PVC (SWR) branch piece, single (single Y equal or unequal) etc complete all as specified and as directed.
12
-
-
S& F stack clamp,110mm bore made out of 50mm by 5 mm flat iron and 16 mm dia round stays including bolts and nuts and securing ends of stay to wall or roof etc complete all as specified and as directed.
50
-
-
Material and labour for brick work in cement mortar1:4 with sub class `B' bricks(using old size burnt bricks) in one brick thick honey comb walling etc complete all as specified and as directed.
13
-
-
Material and labour for brick work in cement mortar1:4 with sub class `B' bricks straight or curved on plan exceeding 6m mean radius with old size bricks etc complete all as specified and as directed.
52
-
-
M&L for brick work with sub class `B' bricks (using old size burnt bricks)straight or curved on plan to any radius in half brick thick walls built in CM 1:4 etc complete all as specified and as directed.
65
-
-
M & L for rendering in 15 mm thick in cement mortar 1:4, on fair faces of brick work, finished even and smooth without using extra cement etc complete all as specified and as directed.
320
-
-
Material and labour for deformed steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) n.less than 0.9mm dia etc complete all as specified and as directed.
280
-
-
M & L for precast cement concrete (1:2:4) type B-1 using 20 mm stone aggregate as in manhole cover slabs round square or rectangular in shape and set in CM (1:4) etc complete all as specified and as directed.
8
-
-
Excavation over areas not exc. 1.50 m deep and getting out in soft/loose soil etc complete all as specified and as directed.
12
-
-
Excavation over areas exc. 1.50 m but not exc 3.00 m deep and getting out in soft/loose soil etc complete all as specified and as directed.
6
-
-
M&L RCC nominal mix Type B1, (1:2:4) (using 20mm graded stone aggregate) as in slabs suported on wall etc complete all as specified and as directed.
4.5
-
-
Form work to the soffits and side suspended slab finish even and smooth etc complete all as specified and as directed.
16.5
-
-
M&L for loose filling with broken bricks aggregate of gauge 80 to 150mm in soakage pits, soakage wells etc complete all as specified and as directed.
4.38
-
-
M&L for loose filling with broken bricks aggregate of gauge 40 to 80mm in soakage pits, soakage wells etc complete all as specified and as directed.
8.5
-
-
M&L for cement concrete (1:3:6) type C-2 (using 20 mm graded stone aggregatre) as in surface channels and drains etc complete all as specified and as directed.
13.5
-
-
M&L for Extra for forming fair finished surfaces of drain or channels, inner girth 30 cms, using extra cement including forms, moulds mitred/ stopped ends etc complete all as specified and as directed.
200
-
-
Carrying out manhole covers/gully traps of any type and any depth removing the sludge/solid content from the manhole/gully trap by manual/ mechanical method and also cleaning the sewage line of any dia and at any depth either by water pressure or by any other flushing or roding and other suitable means at the discretion of the contractor at his own arrangements so as to remove the blockage and making the sewer lines and manhole/gully trap fully functional to the entire satisfaction of Engineer-in-Charge also to remove the sludge/solid contents out of defence land including covering with a layer of earth and repositioning of the RCC/CI cover slab all as directed by the Engineer-in-Charge in NE Zone under. The complaint shall be cleared/rectified to the complete satisfaction of Engineer-in-Charge within 24 hours etc complete all as specified and as directed.
4250
-
-
Desilting of septic tank/soakage pit of any size, type and any depth and removing the sludge/solid content from the septic tank/soakage pit by manual/ mechanical method or any other suitable means at the discretion of the contractor at his own arrangements and make the septic tank/soakage pit fully functional to the entire satisfaction of Engineer-in-Charge also to remove the sludge/solid contents out of defence land including covering with a layer of earth and repositioning of the RCC/CI cover slab etc complete all as specified and as directed.
780
-
-
Cleaning of blockage IWC, EWC, Wash Basin, gully trap, floor trap etc either by hand pump or by rodding or by any other means untill clear flow is observed all as specified and as directed by Engr -in Charge
225
-
-
S&F in repair vitreous china wash down water closet (pedestal pattern) with plastic seat cover including PVC low level flushing cistern 10 ltrs capacity etc complete all as specified and as directed.
5
-
-
S&F in repair for vitreous china squatting pan, Orissa, pattern size 580 x 440 mm white with integral foot rests including connection to trap and to flushing pipe, anti-syphonage pipe etc complete including making good to floor with flush pipe with high or low level flushing cistern and connection to pipe etc complete all as specified and as directed.
5
-
-
Dismantling, floor, hearth or wall tiling including cement mortar bedding etc complete all as specified and as directed.
439.69
-
-
M & L for coloured non skid ceramic tiles 7 to 8 mm thick (square/rectangular) in section , area exceeding 0.06 sqm but not exceeding 0.11 sqm as in floors laid over and including 15mm thick screed bed or bedding layer of mortar for laying floor finishes in CM (1:6) set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles etc complete all as specified and directed.
30
-
-
M&L for Glazed ceramic colour tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of tiles laid over and including 10mm thick CM (1:4) backing coat etc complete all as specified and directed.
10
-
-
Cutting into exisiting manholes for connecting new drains, making good to pipes and rendering, cutting out existing benching and forming branch channel, half round or 3/4 section in cement concrete 1:2:4 type B smooth finished and reforming benching as required, internal dia of pipe 110/150mm etc complete all as specified and as directed.
80
-
-
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc complete all as specified and as directed.
192.6
-
-
M&L for PCC (1:2:4) type B-2 (using 40mm graded stone agg) 100mm thick as in sub base etc complete all as specified and as directed.
200
-
-
M&L for Machine pressed precast concrete interlocking paver block of any shape and size conforming to IS 15658-2006 of 60 mm thickness, M-35 Grade laid, jointed with grey cement and no pigment complete all as specified including preperation of formation bed over 25 mm thick sand cushioning and pointed in colour cement mortar 1:3 etc complete all as specified and as directed.
250
-
-
Excavation in trenches not exceeding 1.5m wide and n.exceeding 1.5m in depth; for foundation , etc not exceeding 10sq.m on planand not exceeding1.5m in depth and getting out in soft/ loose soil etc complete all as specified and as directed.
68
-
-
M& L Plain cement concrete (1:4:8 )Type D-2 using 40mm graded stone aggregate as in foundation filling and mass concrete etc complete all as specified and as directed.
3.9
-
-
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm In soft/ loose soil etc complete all as specified and as directed.
35
-
-
Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point,in soils etc complete all as specified and as directed.
51
-
-
M&L for chequered cement concrete tiles 200x200x25mm thick with 15mm thick screed bed or bedding layer of mortar for laying floor finishes in cement mortar 1:6, etc, set, jointed and pointed in neat cement slurry with grey cement and pigments etc complete all as specified and as directed.
149
-
-