Military Engineer Services Tender
View complete overview of Nagaland MES Tender
Costs
EMD
₹ 97,160Document Cost
₹ 500Tender Fee
Refer Documents
Summary
Special Repair To Bldg No T 11 T 39 And T 76 Or Line Of Asc Bn Provn Of Lightening Conductor In Bldg No P 401 Adm Block Of Fd Hosp Provn Of Geysers For Jco Or Bathroom Of Asc Bn Under Age Br Ii At Rms
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_660483_1Bid Award Id
ViewTender No
8747/C/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Dismantling wall and ceiling board fibre, pulp insulation etc or insulation boards any thickness including cover fillets etc complete all as specified and as directed.
362
-
-
... More
S & F for 4 mm thick of size 600x600mm HSPC (high pressure Steam Cured) pre-Painted self embossed, textured designer board E-Board Classic to be fixed Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre. fixed in ceiling flat or Sloping etc complete all as specified and as directed.
362
-
-
... More
S&F for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws etc complete all as specified and as directed.
598.7
-
-
... More
S&F for pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws etc complete all as specified and as directed.
60
-
-
... More
Dismantling wrought iron or mild steel work of any description not otherwise provided for etc complete all as specified and as directed.
0.11
-
-
... More
S&F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S 1161-1979 grade St.-240 etc complete all as specified and as directed.
100
-
-
... More
M&L for rolled mild steel in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc conforming to Fe 410-W (Gde-E 250) quality-A etc complete all as specified and as directed.
300
-
-
... More
S & F second class hardwood weather boarding, clean sawn, plain, 20 mm thick or feather edged 15 mm to 20mm thick and fixed with 30mm laps etc complete all as specified and as directed.
50
-
-
... More
M&L for second class hardwood as in scantlings clean sawn timber fixed etc complete all as specified and as directed.
2
-
-
... More
M & L for plain fillets, square, rectangular or triangular in section clean sawn, secured with nails 2nd class hard wood exc 13 and n.exc 25 sqcm etc complete all as specified and as directed.
10
-
-
... More
M&L for rendering 15 mm thick in CM (1:4) on one side of lathing finished even and smooth without using extra cement etc complete all as specified and as directed.
300
-
-
... More
M&L for rendering 12 mm thick in CM (1:6) on other side of lathing finished even and smooth without using extra cement etc complete all as specified and as directed.
300
-
-
... More
S & F 0.71 mm dia wire netting of galvanised steel wire of size 12 mm mesh fixed with tinned tack of wire staple etc complete all as specified and as directed.
300
-
-
... More
Taking down Chowkhat or frames exceeding 1.5 Sqm but not exceeding 4 Sqm each etc complete all as specified and as directed.
6
-
-
... More
Taking down Chowkhat or frames not exceeding 1.5 Sqm each with shutters(Without taking off shutters from the frames) etc complete all as specified and as directed.
28
-
-
... More
All as per item No. 18.00 (here-in-before) but exceeding 1.5 Sqm but not exceeding 4 Sqm each `
2
-
-
... More
Material & labour 2nd class hardwood plain, solid straight chowkhats and frames, wrought, framed rebated on the solid,rounded or chamfered, put together with glue pinned at joints etc complete all as specified and as directed.
0.3
-
-
... More
S&F factory made 30mm thick, flush shutter, solid core construction, with particle board core and plywood face panels etc complete all as specified and as directed.
12
-
-
... More
M&L for 35mm thick factory made 2nd class hard wood Glazed and skelton shutter, open rebated and prepared to receive glass, gauge etc. devided into squares with plain chamfered or rounded, mitred and rebated sash bars edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc. sizes of members of shutters as specified in SSR Part-I Section-8 clause 8.24(a) etc complete all as specified and as directed.
12
-
-
... More
S&F Powder Coating aluminium ( minimum thickness of powder coationg 50 micron) frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and as directed.
150
-
-
... More
S&F for powder coating aluminium window and ventilator shutters, fixed type without sash bar, aluminium section of size 40 x 18 x 1.29mm thick including necessary joining cleats, glazing clips, rubber packing, handle , tower bolt anodised aluminium snap beading, screws etc complete all as specified and as directed.
30
-
-
... More
M&L for sheet glass 3mm thick ordinary quality, pin headed type and glazing with oil putty or wooden beads not exceeding 0.5 Sqm in each pane etc complete all as specified and as directed.
20
-
-
... More
S&F mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 18mm, fixed with tinned tacks or galvanized wire staples etc complete all as specified and as directed.
20
-
-
... More
S & F 100 size stainless steel butt hinges etc complete all as specified and as directed.
24
-
-
... More
S & F 75 size stainless steel butt hinges etc complete all as specified and as directed.
10
-
-
... More
Supply & Fixing 150 mm Aluminium handles, cast type, anodised etc complete all as specified and as directed.
8
-
-
... More
Supply & Fixing 100 mm Aluminium handles, cast type, anodised etc complete all as specified and as directed.
4
-
-
... More
S & F 150 mm Aluminium, anodised, barrel tower bolts of extruded section and fixed
8
-
-
... More
S & F 200 mm Aluminium, anodised, barrel tower bolts of extruded section and fixed etc complete all as specified and as directed.
16
-
-
... More
S & F 300 mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast-aluminium alloy and fixed etc complete all as specified and as directed.
7
-
-
... More
S&F in repairs mild steel 300 mm, ordinary rat tail rod pattern springs including roller and roller plate etc complete all as specified and as directed.
7
-
-
... More
Taking down cement plaster on brick walls including raking out joints hacking for key, scrubbing down with water etc complete all as specified and as directed.
350
-
-
... More
M&L for rendering 15mm thick in CM (1:6) on fair faces of brick work or concrete surfaces finished fair and even without using extra cement etc complete all as specified and as directed.
200
-
-
... More
M&L for rendering 15mm thick in CM (1:4) other than fair faces of brick work or concrete surfaces finished even and smooth without using extra cement etc complete all as specified and as directed.
100
-
-
... More
M&L for preparation of new plastered or un plastered surface of walls including cornices, pilasters etc and applying two coats of cement base paintover a coat of primer etc complete all as specified and as directed.
500
-
-
... More
M&L for 2 mm thick Birla white putty/JK white wall care putty on walls etc complete all as specified and as directed.
500
-
-
... More
M&L for applying two coats of oil bound distemper on new plastered surfaces of walls including preparation of surface etc complete all as specified and as directed.
500
-
-
... More
M&L for preparation of new surfaces of steel and iron work of any description over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of redoxide primer on new surfaces in any tint etc complete all as specified and as directed.
20
-
-
... More
All as per item No. 41.00 (here-in-before) but applying two coats of synthetic enamel paint over a coat of pink wood primer on new wooden surfaces .
15
-
-
... More
M&L for preparation of old surfaces of steel and iron work of any description over 10 cm width or girth not otherwise described and applying one coat of synthetic enamel paint in any tint etc complete all as specified and as directed.
20
-
-
... More
M&L for preparation of old painted wood and wood based surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint in any tint etc complete all as specified and as directed.
30
-
-
... More
M&L for Preparation of old decorated surfaces by washing, scrubbing down, and applying one coat of oil bound distemper on walls etc complete all as specified and as directed.
300
-
-
... More
M&L preparation of old surfaces of walls applying one coats of cement base paint etc complete all as specified and as directed.
300
-
-
... More
Demolition of Cement concrete of any description and in any position not otherwise specifically provided for etc complete all as specified and as directed.
6
-
-
... More
M&L for 75 mm thick PCC (1:3:6) type C-2 , (using 40 mm graded stone aggregate)as in plinth protection/aprons/path laid to slope of 1:12, finished fair and even without using extra cement with and including all necessary formwork to divide tha area in panels, finishing exposed edges fair or rounding or chamfering where directed and providing 10 mm wide joints throughout thickness of plinth protection duly filled with mastic filling (one part of hot bitumen 85/25 and three part of fine sand by weight) etc complete all as specified and as directed.
130
-
-
... More
M&L for cement concrete type C-2 (1:3:6) (using 40 mm graded stone agg) as in surface channels and drains etc complete all as specified and as directed.
0.5
-
-
... More
M&L for Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement incl firms moulds etc complete all as specified and as directed.
100
-
-
... More
S&F 20mm dia Harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc complete all as specified and as directed.
100
-
-
... More
S&F Plain mild steel wire,Dia of wire in mm 2.50 galvanised class 3, in detached work such as for mosquito nets and fixing to straining bolts, hooks, eyes, etc complete all as specified and as directed.
0.4
-
-
... More
Demolition of brick work built in cement mortar or cement lime mortar including all quoins, arches etc complete all as specified and as directed.
2
-
-
... More
Material & labour for brick work with sub class 'B' bricks(using old size burnt bricks) straight or curved on plan to any radius in half brick thick walls built in CM 1:4 etc complete all as specified and as directed.
87
-
-
... More
Demolition Stone slabs and tiles of any description or thickness in floors, aprons etc complete all as specified and as directed.
30
-
-
... More
M & L for PCC 25mm thick type B-0, (1:2:4) (using 12.5 mm graded stone aggregate) as in levelling corse of floor etc complete all as specified and as directed.
280
-
-
... More
M&L for Coloured /light shade vitrified ceramic tiles 10mm thick (square/regtangular) polished , area of each tiles exc 0.18 sqm but not exc 0.36 sqm as in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, laid over and including 15 mm thick screed bed or bedding layer in cement mortar (1:6) etc complete all as specified and as directed.
280
-
-
... More
All as per Item No. 57.00 (here-in-before) but in skirting etc over and including 10 mm thick bedding layer in CM 1:4.
20
-
-
... More
Taking down carefully copper/ aluminium point wiring (light, fan, socket or power) complete, including fitting & fixtures such as switches with board, ceiling roses, pendents, bell/ buzzer, bell push, lamp holders, regulators, sockets, light fittings etc., removing material from site and making good to the disturbed surfaces of walls, ceiling, floors etc. including making good the disturbed surfaces and paint touch up to match with the existing surface complete all as specified and as directed.
182
-
-
... More
M&L for Point wiring complete with two runs of 1.5 sqmm single core PVC insulated FR-LSH cable 1100 volts grade with multi-stranded copper conductors, drawn through and including PVC double locked Casing & caping including provision of 1.5 sqmm, FR-LSH, PVC insulated copper cable as earth continuity conductor connected to common earth dolly, including PVC rectagular box for mounting switches / sockets / regulators etc. with 3 mm thick plastic laminated sheet cover of suitable size as required at site and 50 mm deep complete all as specified and as directed. Make : Richa/Finolex/RR Kabel, Make of Caping & Casing : Prestoplast /Richa /Supreme
-
-
-
... More
(a) One light/Fan pointcontrolled by one, one way switch .
105
-
-
... More
(b) One 3 pin socket outlet 5 Amps on the same board with other switches.
5
-
-
... More
(c) One 3 pin socket outlet 5 Amps on the independent board
58
-
-
... More
All as per item No- 60.00 here-in-before but with 2.5 Sq mm for 3 pin 15 Amps socket point controlled by one switch on independent board and 2.5 Sq mm copper conductor green in colour as earth continuity conductor connected to common earth dolly etc complete all as specified and as directed.
34
-
-
... More
M&L for Switch piano flush type single pole, one way 6A etc complete all as specified and as directed. Make :Anchor/Legrand/Kinjal
110
-
-
... More
M&L for Socket outlet, 2 in 1, 5 pin 5A flush type etc complete all as specified and as directed.
5
-
-
... More
M&L for Switch Socket combination, 2 in 1, 3 pin 6A flush type etc complete all as specified and as directed.
58
-
-
... More
M&L for Switch Socket combination, 2 in 1, 5 pin 6A/16A flush type etc complete all as specified and as directed.
34
-
-
... More
M&L for stepped type electronic fan regulator 100 Watt socket size flush type on the existing phenolic laminated sheet etc complete all as specified and as directed.
28
-
-
... More
M&L for ceiling rose 3 terminal PVC/Polycarbonate isolated body with PVC round/squareblock complete all as specified and directed etc complete all as specified and as directed.
89
-
-
... More
M&L for sub main wiring with two runs of 4.0 Sq mm and one run of 4.0 Sq mm for earth wire with multi standard copper conductors of , 1100 volts grade, drawn through and including PVC double locked Casing & caping incl taking down old unsv complete all as specified and as directed etc complete all as specified and as directed.
135
-
-
... More
S&F for, LED light fitting 1 x20 W (4 FT), wall /surface mounted, integrated type with all accessories internally prewired and including connecting up with and including twin/three core twisted flexible copper conductor cable of suitable size in & incl flexible hose from ceiling rose to fitting complete all as specified and as directed etc complete all as specified and as directed.
43
-
-
... More
S&F for, LED light fitting 1 x9 W (2 FT), wall /surface mounted, integrated type with all accessories internally prewired and including connecting up with and including twin/three core twisted flexible copper conductor cable of suitable size in & incl flexible hose from ceiling rose to fitting etc complete all as specified and as directed.
4
-
-
... More
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling and connecting up with driver, three core flexible copper conductor of suitable size incl taking down etc complete all as specified and as directed.
16
-
-
... More
M&L for LED 1x25W Security light fitting, drawn through including GI bracket of suitable size light grade 1.4 mtr bend to shape and MS clamps made out of flat iron of size 40x4 mm -02 Nos including nuts, bolts, washer as required and connecting up with flexible copper cable of size 0.75 Sq mm 3 core from ceiling rose to the light fitting and taking down old unsv bldg security light etc complete all as specified and as directed.
13
-
-
... More
M&L for MCB Distribution board double door type SPN 8 way, sheet steel, powder painted, with neutral link & earth bar etc. and fixing MCBs of various rating capacity including taking down old unsv MCB DBs etc complete all as specified and as directed.
8
-
-
... More
M&L for MCB Distribution board double door type SPN 4 way, sheet steel, powder painted, with 200 Amp rated copper bus bar neutral link & earth bar etc. and fixing MCBs of various rating capacity etc complete all as specified and as directed.
5
-
-
... More
M&L for MCB SPN 32 Amps, 230 volts, 50 Hz suitable for fixing in MCB DB 'C' series etc complete all as specified and as directed.
5
-
-
... More
M&L for MCB SPN 40-63 Amps 'C' series, 230 volts, 50 Hz suitable for fixing in MCB DB incl taking down old unsv MCB etc complete all as specified and as directed.
3
-
-
... More
M&L for MCB SP 6-32 Amps 'C' series, 230 volts, 50 Hz suitable for fixing in MCB DB incl taking down old unsv MCB etc complete all as specified and as directed.
28
-
-
... More
Supply, Fixing and testing of vertical type wall mounted storage water heater of Capacity 25 Ltrs BEE 5 Star rated or minimum Standing Loss of 0.511 kWh , 240V, 50Hz with Maximum power consumption of 2KW , dry powder fero glass line coating technology for inner tank with incoloy heating element with minimum 4 years warranty , ABS outer body , 2 units of PVC connection pipe with length of 450mm length for hot and cold water supply with etc complete all as specified and as directed.
20
-
-
... More
Supply and laying tubes Medium grade galvanised GI tubing with all fittings, fixed complete to walls/poles/laid in floors/trenchs/road crossing of size 15 mm dia bore including etc complete all as specified and as directed.
56
-
-
... More
S&F Stop valves, cast copper alloy, fancy type, chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed etc complete all as specified and as directed.
20
-
-
... More
S&F 15mm bore Bib tap fancy type chromium plated with long shank etc complete all as specified and as directed.
20
-
-
... More
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) etc complete all as specified and as directed.
28
-
-
... More
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers etc complete all as specified and as directed. Old Exhaust fan shall be deposited to MES AGE(E/M) Store
1
-
-
... More
Taking down LT UG cable/ service connection of any size and M&L for laying of LT UG cable, XLPE insulated, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of 16 sq mm, 2 core complete all as specified and as directed. NOTE :- (i) Excavation and earth work, sand cushioning, cable protection cover, pipe etc. shall be measured and paid seperately under relevant items. Make : Havells/Richa/Gloster
150
-
-
... More
Taking down LT UG cable/ service connection of any size and M&L for laying of LT UG cable, XLPE insulated, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of 25 sq mm, 2 core complete all as specified and as directed. NOTE :- (i) Excavation and earth work, sand cushioning, cable protection cover, pipe etc. shall be measured and paid seperately under relevant items. Make : Havells/Richa/Gloster
100
-
-
... More
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth and getting out in soft/ loose soil etc complete all as specified and as directed.
35.41
-
-
... More
Returning filling in trenches including spreading leveling watering and well ramming in layers not exceeding 25 cm thick all etc complete all as specified and as directed.
16.53
-
-
... More
Removing of excavated material not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point etc complete all as specified and as directed.
18.91
-
-
... More
M&L for spread fine river sand in trenches complete all as specified ans as directed. NOTE: For measurement purpose, punned down thickness shall only be taken.
14.18
-
-
... More
M&L for laying brick sub class 'B' old size burnt bricks for cable protection of size 230mmx115mmx75mm etc complete all as specified and as directed.
1522
-
-
... More
Supply & laying tubes ' Medium grade' galvanised, with all fittings, fixed complete to walls, poles, ceilings or laid in floors/ trenches/ road crossing for protection of cables of size 40 mm dia bore including taking out unsv GI tubing etc complete all as specified and as directed.
24
-
-
... More
M&L for cross arms, bracings, supports, clamps and back plates fabricated from steel section including nuts, bolts, washers, welding bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of synthetic aluminium paint. (For MS Clamps and Hooks) etc complete all as specified and as directed.
0.5
-
-
... More
Supply and fixing for Air termination, single pointed aluminium rod 12mm dia and 300mm long complete all as specified and as directed.
6
-
-
... More
Supply and fixing of Aluminium strip 25 x 3.15mm with porcelain insulators saddles and fixing screws etc. for roof conductors above ground etc complete all as specified and as directed. Note:-
(a) All the roof conductors down conductors and air termination rod shall be mounted on suitable size porcelain insulators/saddles.
(b) Any portion of the lightning condcutor, air termination rod and the strip GI/Aluminium are not in contact with the building.
(c) The cost of porcelain insulators/saddle with fixing accessories is deemed to be included in quoted rate.
(d) Conductor shall be properly secured to the building.
(e) Due case taken to avoid leakage/damage in roof of the bldg, repair/replacement cost of the leakage deemed to be included in quoted rate.
(f) The lightning condcutor shall be secured at not more than 1.20 mtr apart for horizontal run and 1 mtr for vertical run.
140
-
-
... More
Supply and fixing for Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hexagonal head screw etc complete all as specified and as directed.
6
-
-
... More
Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised iron strip 32x 6mm as earthind lead by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of required size (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion etc complete all as specified and as directed. Note: Contractor should submit earth test report to Eng-in-charge.
6
-
-
... More
M&L for earthing complete with galvanized steel earth plate electrode of size 600x600x6mm thick buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of the earth plate not less than 1.5 mtr below normal ground level connected to galvanised earth lead wire 4 mm dia as earth lead connectd by means of bolts, nuts, washers and check nuts all as shown in electrical plate No 3 of MES SSR Part-I, including testing on completion complete all as specified and as directed. NOTE:- (i) The unit rate shall also included for earth work in hard/ dense soil, PCC (1:3:6) type C1 chamber, CI cover 10 m thick, funnel with GI watering pipe 20mm dia Medium grade, GI protection pipe light grade 15mm dia and wire mesh complete in addition to item No 1 (a) to (e) of preamble (notes) under sub heading earthing, specified on Sl Page No 389 of MES SSR Part-II. (ii) Earthing lead and GI protection pipe beyond 7.5m will be measured and paid separately. (iii) Test points shall be made of GI strip 32x6 mm bridge type mounted on insulators, where ever applicable
3
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements