Military Engineer Services Tender
View complete overview of Nagaland MES Tender
Costs
EMD
₹ 98,640Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_669630_1Bid Award Id
ViewTender No
8795/C/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 50 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc all as specified and directed.
18
-
-
Supply and laying tubes Medium grade galvanised GI tubing with all fittings, fixed complete to walls/poles/laid in floors/trenchs/road crossing of size 15 mm dia bore including complete all as specified and as directed.
360
-
-
S&F Stop valves 15mm, cast copper alloy, fancy type, chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed all as per specified and as directed.
28
-
-
S&F 15mm bore Bib tap fancy type chromium plated with long shank all as per specified and as directed
64
-
-
M&L for sub main wiring with two runs of 4.00 Sq mm and one run of 4.00 Sq mm for earth wire with multi standard copper conductors, 1100 volts grade, drawn through and including PVC double locked Casing & caping including complete all as specified and as directed. NOTE:- Two runs of 4.00 Sq mm + one run of 4.00 Sq mm and one run of PVC casing & capping and its accessories of suitable size shall be measured as one unit length. Make:- Richa/RR Kabel/Finolex Make of caping/casing & PVC boxes :- Prestoplast/Finolex/supreme/Richa
45
-
-
M&L for sub main wiring with two runs of 2.5 Sq mm and one run of 2.5 Sq mm for earth wire with multi standard copper conductors, 1100 volts grade, drawn through and including PVC double locked Casing & caping including complete all as specified and as directed. NOTE:- Two runs of 2.5 Sq mm + one run of 2.5 Sq mm and one run of PVC casing & capping and its accessories of suitable size shall be measured as one unit length.
725
-
-
M&L for MCB Distribution board double door type SPN 4 way, sheet steel, powder painted, with 200 Amp rated copper bus bar neutral link & earth bar etc. and fixing MCBs of various rating capacity complete all as specified and as directed. Make:- Legrand/ABB/Siemens
3
-
-
Supply and fixing MCB SPN 32 amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and as directed. Make:- Legrand/ABB/Siemens
3
-
-
Supply and fixing MCB SP 6-32 amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and as directed. egrand/ABB/Siemens
6
-
-
M&L for metal clad AC socket point single pole and neutral enclosure with a tow pin and earth plug and socket complete with one single pole MCB SP 20 Amps complete all as specified and as directed.
19
-
-
Supply and fixing rotational moulded polythylene water storage tank capacity 500 ltr, double layer ISI Marked with lid cylindrical vertical with closed top hoisted mounted on staging /roof of OTM//Md Accn of the following capacity all as directed
60
-
-
Supply, laying/fixing and replacement of steel tubing galvanised medium grade with all fitting in trenches or fixed to walls, ceilings or laid in floors complete all as specified and directed of following sizes :-
-
-
-
20mm bore
225
-
-
25mm bore
330
-
-
M&L for cutting existing steel water tubing in position for alteration or addition for replacing damaged length/fittings etc of following size 20 mm bore etc complete all as specified and directed.
60
-
-
S & F in replacement of Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of 20 mm dia bore etc complete all as specified and directed.
60
-
-
S&F in replacement of ball brass valves ,high pressure with polythene float and flynut complete ,screwed for iron pipe or brass ferrule and fixed of size 20 mm dia bore ,including taking down old unserviceable ball valve etc complete all as specified and directed.
60
-
-
S & F MS plate of any size (as directed by Engineer-in- Charge) including cutting/welding complete all as specified and directed.
160
-
-
Supply and fix staging / frame work for water tanks using standard mild steel sections like angle iron / MS pipe / flat iron / sheets etc using steel of Fe 290 (Gde E-165) quality - A including necessary welding suitable to keep 500 ltrs PVC water tank complete all as specified and directed by Engr in charge.
425
-
-
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop copper strip of size 32 mm x 6 mm connected to test point complete all as specified and directed
15
-
-
M&L for test point terminal block made of gun metal or phosphorus bronze size 75 x 75 x 25 mm, drilled and screwed including 3 nos. 8 mm dia 25 mm long hex. Head screw complete all as specified and as directed.
6
-
-
Material & labour for Chemical earthing with copper plate electrode 90x60cmx5mm thick buried directly in ground vertically to a depth not less than 4.50 mtr below normal ground level with top edge of plate not less than 3.40 mtr below ground level & complete size of earth pit 1.60 x 1.60m, copper plate electrode connected to copper strip 50x 6mm as main earthing lead by means of tinned copper/brass bolts, nuts, check-nuts and washers besides brazing (copper strip 0.5 mtr shall be over lapped with copper plate by barzing) all as directed and connected to earth test point all as specified and testing on completion with and including necessary excavation and earth work in any type of soil, earth electrode, earthing lead from electrode to test point up to 7.5m, adequate quantity of charcoal common salt & magnesium sulphate in alternate layers of 100mm thick each x 6 layers all around the plate or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe, 40mm dia GI medium grade earth lead protection pipe, CI frame and cover, wire, copper lugs, mesh etc complete all as specified and directed.
6
-
-
Supply installation & testing of silent Diesel Engine driven generating set 415 volts, 3 phase 4 wire, engine as per IS:10001/ 10002 and Alternator as per IS: 13364 complete with relay panel and switch gears for automatic starting on main failure, control panel having meter and sound proof canopy as per CPCB norms IV and foundation etc. of capacity 40 KVA all as specified and directed by Engr-in-charge. Note:- Rates for AMF panel suitable for 40 KVA DG Set, Plinth/ foundation as per manufacturer manual and rates for commissioning and testing also included in quoted rate pl
1
-
-
Supply and laying under ground XLPE insulated PVC sheathed (Heavy duty) armoured 1100 volts grade aluminium conductor cable of size 35 Sqmm 3.5 core laid in trenches as per IS 7098 (Part I) including connection cable glands, aluminium lugs etc complete all as specified and as directed.
Note : Earth work, brick protection and sand cushioning and GI Pipe shall be measured and paid separately under respective item.
130
-
-
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron strip 25×4mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion.
8
-
-
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25x4mm galvanised iron strip etc complete all as specified and directed
20
-
-
Excavation in trenches, not exceeding 1.5 m wide and n. exc 1.5 m in depth for laying of cable for soft/ loose soil and getting out etc complete all as specified and directed
64.65
-
-
Returning, filling in including spreading, leveling, watering and well ramming in layers n. exc 25 cm apart for soft/loose soil etc complete all as specified and directed.
34.48
-
-
Removing of excavated surplus soil to a distance n. exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point etc complete all as specified and directed
30.17
-
-
M & L for dry Sand cushioning in trenches for protection of cable including watering and consolidation all as specified and directed.
Note: Punned thickness shall be considerd for measurment purpose
6.06
-
-
M & L for well burnt brick sub class B old size laying in trenches perpendicular to axis of the cable for protection of electric cable all as specified and directed.
2122
-
-
Supply & laying GI tubing 'light grade' galvanised, with all fittings, fixed to walls, poles, ceilings complete for protection of cables of size 40 mm dia bore including taking out unsv GI tubing complete all as specified and as directed.
36
-
-
Supply, installation, testing and commissioning of feeder Pillar, Powder coated CRCA steel sheet feeder pillar housing 2.0mm thick (minimum) 9 amp 2 conactors and raise lower push buttons for motors operation, incoming terminals of 25 sqmm and outgoing terminals of 16 sqmm for power cable and 2.5 sqmm for motors mounted on suitable foundation, factory made powder coated (CPRI approved) LT panel board, outdoor type, weather, dust and vermin proof (IP-64), made out of CRCA sheet 2mm thick with base frame of angle iron 25x25x3 mm suitable for 415 volts 3 phase, 50 Hz, 4 wire system with front side openable with single shutter, hinged and locking arrangement and slanted roof. The size of panel boards shall be suitable for housing the accessories given here under. The panel board shall comprise of following items with and including necessary connection complete all specified and directed :-
"(i) MCCB 63 Amp 4 pole 415 Volts AC with thermal magnetc adjustable type 16 KA lcs= 100% lcs-01 No
(ii) Digital Timer Switch, 16A, 50 Hz - 01 No
(iii) 40 Amps, 4 pole, Contractor suitable for automatic switch ON and OFF of the luminaries -01 No
(iv) DOL starter 3 Ph, 1HP -01No
(v) Aluminum bus bar 100 Amps (Min 15x3 mm) capacity of suitable length duly insulated with colour code -04 Nos
(vi) Digital voltmeter, square mouthed 96 mm square 0-500 volts with inbuilt selector switch -01 Nos
(vii) Digital Ammeter square mouthed 96mm square 0-50 Amps with CTs and selector switch -01 Nos
(viii) Phase indicator lamp LED clustar type RYB (Set of Three)- 01 Set
(x) Copper cable connection with lugs, aluminum cable gland for incoming & out going cables etc.
Note :- Quoted rates are inclusive of followings :-
(i) Contractor will get approved the Drawing of panel
(ii) Platform of suitable size in PCC 1:2:4 type B-1 minimum 40cm below NGL and 45 cm above from NGL duly plastered in CM 1:3 , 5MM thick and painted with two coat of cement based paint."
4
-
-
Supply and lay XLPE insulated PVC bedded galvanised steel strip or wire armoured electric power cables(heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 Sqmm 3.5 core etc complete all as specified and directed
250
-
-
Excavating in post holes (or similar holes) each n exc 0.5 cu. M, getting out, returning, filling in and raming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50m and making good surface in soft/ loose soil etc complete all as specified and directed
12
-
-
M&L for Plain Cement concrete type D-2, (1:4:8) (using 40mm graded stone aggregate) as in foundation filling and mass concrete etc complete all as specified and directed
5
-
-
S&F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S 1161-1979 grade St.-240 etc complete all as specified and directed
1100
-
-
S&F steel work in purlins including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S 1161-1979 grade St.-240 etc complete all as specified and directed.
500
-
-
S&F steel work in pillars trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S 1161-1979 grade St.-240 etc complete all as specified and directed
400
-
-
S&F plates (plain or chequered) channels. Square cut or notched ) (ordinary and counter sunk) forming holes, without any attachment, Fe 410-W etc complete all as specified and directed.
80
-
-
S&F mild steel bolts, purpose made, with hexagonal or square head one end and screwed the other end to be fitted with washer and one hexagonal or squre nut n exc 15cm long 12mm dia etc complete all as specified and directed
60
-
-
S&F mild steel bolts, purpose made, with hexagonal or square head one end and screwed the other end to be fitted with washer and one hexagonal or squre nut exc 30cm long and dia 25mm etc complete all as specified and directed
85
-
-
M&L for applying two coats synthetic enamel paint over a coat of red oxide primer on new steel surfaces of any des-cription, over 10cm in width or girth, not otherwise described including prepration of surface etc complete all as specified and directed
170
-
-
S&F Prepainted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws etc complete all as specified and directed
98
-
-
S&F Prepainted galvalume aluminium zinc coating GI based Plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws etc complete all as specified and directed
13.5
-
-
M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cm 1:6 complete all as specified and as directed.
11.6
-
-
M & L for hardcore of gauge not exceeding 63 mm of broken granite stone, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface etc complete all as specified and directed
22.5
-
-
M&L for 75 mm thick Cement concrete type D 2, (1:4:8) (using 40 mm graded granite stone aggregate) in sub base of flooring etc complete all as specified and directed
150
-
-
M & L for PCC (1:2:4) type B2 (using 40mm graded stone aggregate) 100 mm thick as in floor finishing cement concrete surface even and smooth without using extra cement including fixing of plastic dividing strips complete all as specified.
Note:- plastic dividing strips measured and paid seperetely as supply only.
150
-
-
Supply only plastic dividing strips, 1.5mm thick and width 28mm etc complete all as specified and directed.
84
-
-
M&L for Rendering 15mm thick cement plaster in CM 1:6 on brick work/concrete surfaces finished even and fair without using extra cement complete all as specified and directed.
20
-
-
M&L for rendering 15 mm thick cement plaster in CM 1:4 on brick work/concrete surfaces finished even and fair extra cement complete all as specified and directed.
20
-
-
M&L for preparation for newly plastered surfaces of walls and applying three coats of white wash complete all as specified and as directed
40
-
-