Military Engineer Services Tender
View complete overview of Nagaland MES Tender
Costs
EMD
₹ 96,000Document Cost
₹ 500Tender Fee
Refer Documents
Summary
Repair Maint Of Refrigerator Deep Freezer Vrf Ac Plants And Tower Ac At Rajbari Area Dimapur And Rms
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_650429_1Bid Award Id
ViewTender No
8731/C/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Taking down carefully copper/ aluminium point wiring (light, fan, socket or power) complete, including fitting & fixtures such as switches with board, ceiling roses, pendents, bell/buzzer, bell push, lamp holders, regulators, sockets, light fittingsetc. removing materials from site and making good to the disturbed surfaces of walls, ceiling floors etc. including making good the disturbed surfaces and paint touch up to match with the existing surface complete all as specified and as directed.
15
-
-
... More
All as per item No-4 here-in-before but with 2.5 Sq mm for 3 pin 15 Amps socket point controlled by one switch on independent board and 2.5 Sq mm copper conductor green in colour as earth continuity conductor connected to common earth dolly complete all as specified and as directed.
15
-
-
... More
M&L Switch socket combination 2 in 1, 5A/16A, 5 in 1 flush type complete all as specified and directed by Engr-in-Charge.
15
-
-
... More
M & L for taking down/ Disconnecting unserviceable Deep frezzer/ Refrigerator compressor and supply and fix new sealed rotary / reciprocating compressor with built-in OLP, thermostat including brazing the suction / discharge lines suitable for existing model of filling the gas and testing on all as specified and directed by Engineer - in - Charge following cooling appliances.
-
-
-
... More
For refrigerator/ deep frezzer 90 to 195 ltr capacity
10
-
-
... More
For refrigerator/ deep frezzer 200 to 410 ltr capacity
16
-
-
... More
Supply & charging the Refrigerarent R-134 or as existing refrigerant to Refrigerators/ deep freezer up to 195 ltr capacity including repairing the leakage if any and testing complete all as specified & directed by Engineer-in-charge
28
-
-
... More
All as per item No 8 here-in-before but for 200 ltrs to 410 ltrs capacity
42
-
-
... More
Taking down/ Disconnect unserviceable Deep frezzer/ Refrigerator PCB (Printed Circuit Board) and supply and fix new PCB suitable for existing model of following cooling appliances, all as specified and directed by Engineer - in - Charge.
-
-
-
... More
Upto 195 ltrs
19
-
-
... More
200 to 410 ltrs
26
-
-
... More
Disconnect and remove unserviceable Refrigerator coolling chamber and supply and fix new colling chamber suitable for existing model of following cooling appliances, all as specified and directed by Engineer - in - Charge.
Make : Kirlosker/Tecumseh/ Sriram/ Voltas/Carrier.
-
-
-
... More
Upto 195 ltrs
16
-
-
... More
200 to 410 ltrs
22
-
-
... More
Taking down unserviceable condensing coil unit and supply and fix new condensing coil unit suitable for Refrigerator of capacity upto 310 Ltrs complete all as specified and directed by Engineer-in-Charge
18
-
-
... More
M & L for Fan Motor of suitable for refrigerator/ deep freezer as per existing model and make for fwg capacities:-
-
-
-
... More
Upto 195 ltrs
16
-
-
... More
200 to 410 ltrs
32
-
-
... More
M&L for replacement of the following parts/items of refrigerator/Deep Freezer 190 ltr to 410 ltr capacity,complete all as specified and directed.
-
-
-
... More
Starting capacitor of capacity 10 MFD/20MFD.
Make : Asian/Keltern/Unistar/EPSCO/Keal/as per existing
120
-
-
... More
Running capacitor of 30 MFD/36 MFD capacity.
Make : Asian/Keltron/Unistar/EPSCO/Keal/as per existing
100
-
-
... More
Running/Fanmotor capacitor of 4 to 6 MFD.
Make : Asian/Keltron/Unistar/EPSCO/Keal/as per existing
80
-
-
... More
Starting relay open type for refrigerator Make: Renutral/Shriram/Indfoss/as per existing
60
-
-
... More
Overload protector for refrigerator Make: Renutral/Shriram/Indfoss/as per existing
55
-
-
... More
Thermostat for Refrigerator Make : Renutral/Shriram/Indfoss/as per existing
40
-
-
... More
Wiring kit for Refrigeration/Deep Freezer
32
-
-
... More
Refrigerator/Deep freezer filter
30
-
-
... More
Selector switch as per sample
18
-
-
... More
Timer switch suitable for refrigerator/deep freezer of capacity 90 to 410 ltrs.
Make - LG,Whirlpool, bluestar
45
-
-
... More
Door gasket with magnetic strip for upto 195 ltrs refrigerator
8
-
-
... More
Door gasket with magnetic strip for 200 to 410 ltrs refrigerator/deep freezer
20
-
-
... More
Biometal for Deep freezer/Refrigerator
26
-
-
... More
Sensor as per existing sample
40
-
-
... More
Pin type / screw type bulb suitable for 90 ltr to 360 ltr. Refrigerator.
25
-
-
... More
Door switch, 230 volt for refrigerator
16
-
-
... More
M & L for Flushing and leak testing the complete system Refrigerator and deep freezer with nitrogen gas and making good leaking portion by brazing and topping up compressor oil complete all as specified and as directed by Engineer in charge. Note: Cost of brazing and topping up of compressor oil is deemed to be included in quoted rate.
32
-
-
... More
Material and labour for replacement of door lock with keys-2 nos. for any capacity of refrigerator as per sample approved by Engr-in-Charge complete all as specified and directed by Engr-in-Charge.
2
-
-
... More
Material and labour for replacement of PVC accessories and suitable for upto 195 Ltrs Cap. Refrigerator complete of matching size/ as per sample complete all as specified and directed by Engr-in-Charge.
24
-
-
... More
Material and labour for replacement of PVC accessories suitable for upto 320 ltrs capacity refrigerator as per sample, complete of matching colour complete all as specified and directed by Engr-in-Charge.
40
-
-
... More
Material and labour for replacement of refrigerator door handle of 165 to 320 Ltrs Capacity of any make and model complete all as specified and directed by Engr-in-Charge.
20
-
-
... More
S&F MCB SPN upto 40 Amp, 10 kA, ISI Marked complete all as specified and directed by Engr-in-Charge.
20
-
-
... More
Sunpply and fixing of 4.00 Sqmm 3 core multi stranded copper conductor cable (FRLSH) 1100 Volt grade drawn through 20/25 mm dia PVC Casing Caping after and inclduing taking down existing submain wiring complete all as specified and as directed.
50
-
-
... More
M&L for permanent type stiker of size 100 x 50 mm having following details in letters not exceeding 25 mm, complete all as specified and as directed. (i) Machine Srl No______________. (ii) MES No___________________. (iii) Date set to work.____________. (iv) PRB Page No ______________. (v) Location___________________.
100
-
-
... More
Attending day to day complaint to find out the fault of Refrigeration, deep freezer, tower ac and VRF AC plant all as directed by Engr-in-charge.
250
-
-
... More
M& L for servicing of IVRFB-10THN VRF Air Conditioners including inspecting ACs for standing pressure and find out type of gas used, washing outdoor unit by jet pressure including clean the all parts of indoor/ outdoor unit and dry the all parts with clean cloth and testing on completion of proper servicing complete all as directed by the Engineer-in- Charge.
12
-
-
... More
M& L for servicing of IVRFB-14THN VRF Air Conditioners including inspecting ACs for standing pressure and find out type of gas used, washing outdoor unit by jet pressure including clean the all parts of indoor/ outdoor unit and dry the all parts with clean cloth and testing on completion of proper servicing complete all as directed by the Engineer-in- Charge.
12
-
-
... More
M& L for servicing of IVRFB-16THN VRF Air Conditioners including inspecting ACs for standing pressure and find out type of gas used, washing outdoor unit by jet pressure including clean the all parts of indoor/ outdoor unit and dry the all parts with clean cloth and testing on completion of proper servicing complete all as directed by the Engineer-in- Charge.
6
-
-
... More
Comprehensive, preventive, and periodical maintenance of VRF AC plant by OEM or authorised partner of OEM (Make blue Star) including Fixing/ Labour Charges for replacing of defective components/ accessories of complete VRF AC unit of cap upto 16 HP all as required at site and directed by Engr-in-charge for the following:-
9
-
-
... More
Supply of VRF ODU controller for VRF AC Plant of 10/14/16 HP capacity complete all as specified and directed by Engr-in-Charge.
4
-
-
... More
Supply of drive for ANB78FVA SIAM compressor for 14 HP capacity complete all as specified and directed by Engr-in-Charge.
4
-
-
... More
Supply of VRF ODU Fan controller V3.0 for VRF AC plant of 10/14/16 HP capacity complete all as specified and directed by Engr-in-Charge.
6
-
-
... More
Supply of compressor scroll 3 Ph/50 Hz ANB78FVSMT complete all as specified and directed by Engr-in-Charge.
1
-
-
... More
Supply of DMUB6D1BL DC Motor 560 W 3/4 inc complete all as specified and directed by Engr-in-Charge.
4
-
-
... More
Supply of capacitor PCB for IVRF cap 14/16 HP complete all as specified and directed by Engr-in-Charge.
4
-
-
... More
Supply of IVRF Noise filter PCB-14 HP complete all as specified and directed by Engr-in-Charge.
4
-
-
... More
Supply of IVRF bridge rectifier for 14/16 HP complete all as specified and directed by Engr-in-Charge.
3
-
-
... More
Supply of VRF ODU power board for 10/14/16 HP cap complete all as specified and directed by Engr-in-Charge.
2
-
-
... More
Supply of IVRF Communication PCB for cap 10/14/16 HP cap complete all as specified and directed by Engr-in-Charge.
6
-
-
... More
Supply of Temp sensor SE VRF ODU DLT for cap 10/14/16 HP complete all as specified and directed by Engr-in-Charge.
1
-
-
... More
Supply of Temp sensor VRF ODU ambient OH for cap 10/14/16 HP complete all as specified and directed by Engr-in-Charge.
3
-
-
... More
Supply of Drive for ANB78FVA SIAM compressor for 16 HP capacity complete all as specified and directed by Engr-in-Charge.
2
-
-
... More
Supply of compressor scroll 3 Ph/50 Hz ANB78FVSMT for cap 16 HP complete all as specified and directed by Engr-in-Charge.
2
-
-
... More
Supply of drive for ANB66FVA SIAM Compressor for VRF cap 10 HP complete all as specified and directed by Engr-in-Charge.
3
-
-
... More
Supply of Compressor scroll 3 Phase/50 HZ ANB87FVNMT SIAM for VRF cap 10 HP complete all as specified and directed by Engr-in-Charge.
2
-
-
... More
Supply of DMUB8D1BL DC motor DMUB 750W 5/8 PANASON complete all as specified and directed by Engr-in-Charge.
3
-
-
... More
Supply of IVRF Noise filter PCB-10 HP complete all as specified and directed by Engr-in-Charge.
2
-
-
... More
Supply of IVRF capacitor PCB -10HP complete all as specified and directed by Engr-in-Charge.
3
-
-
... More
Supply of VRF FREE Large Cassette PCB complete all as specified and directed by Engr-in-Charge.
2
-
-
... More
Supply of VRF HI-Wall PCB complete all as specified and directed by Engr-in-Charge.
2
-
-
... More
Supply of Room Temp Sensor complete all as specified and directed by Engr-in-Charge.
1
-
-
... More
Supply of Liquid Temperature sensor complete all as specified and directed by Engr-in-Charge.
4
-
-
... More
Supply of Gas Temp sensor complete all as specified and directed by Engr-in-Charge.
4
-
-
... More
Material and labour for filling up and charging of R-410 refrigerant or suitable for Tower AC and VRF AC Plant complete all as specified and directed by Engr-in-Charge.
60
-
-
... More
Supply and fix fan motor including fan blade suitable for 3/4/8 Ton Tower AC, as per existing sample complete all as specified and directed by Engr-in-Charge.
3
-
-
... More
Supply and fix Blower motor with blower suitable for 3/4/8 Ton Tower AC, as per existing sample complete all as specified and directed by Engr-in-Charge.
3
-
-
... More
Supply and fix PCB indoor unit suitable for 3/4/8 Ton Tower AC, as per existing sample complete all as specified and directed by Engr-in-Charge.
4
-
-
... More
Supply and fix PCB outdoor unit suitable for 3/4/8 Ton Tower AC, as per existing sample complete all as specified and directed by Engr-in-Charge.
3
-
-
... More
Supply and fix Swing motor suitable for 3/4/8 Ton Tower AC, as per existing sample complete all as specified and directed by Engr-in-Charge.
4
-
-
... More
Supply and fix Swing Blade suitable for 3/4/8 Ton Tower AC, as per existing sample complete all as specified and directed by Engr-in-Charge.
3
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements