Repair Maint Of Lt Bush Bar Feeder Pillar Boxes Maint Of Sub Stns Painting And Other Misc Works And Repair Maint Cleaning Of Sewage Line Drain Foot Path Hard Standing Under Age Br Ii At Rms
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_667676_1Bid Award Id
ViewTender No
8769/C/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Removing excavated material n.exc 50 m and depositing where directed at a level n exc 1.5 m above the starting point etc complete all as specified and directed.
113.91
-
-
M&L for spread fine river sand in trenches complete all as specified ans as directed. Note: For measurment,punned down thickness shall be measured.
129.6
-
-
M&L for laying brick sub class 'B' old size burnt bricks for cable protection of size 230mmx115mmx75mm etc complete all as specified and directed.
12800
-
-
Supply, laying & testing XLPE insulated screened PVC bedded galvanised steel strip or wire armoured, electric power cable (Heavy duty) with stranded aluminium conductor 1100 volts grade of size 10 Sqmm 2 core incl taking out old unsv cable from trenches etc complete all as specified and directed.
150
-
-
All as per item No 07 (here-in-before) but 16 Sqmm 4 core
150
-
-
All as per item No 07 (here-in-before) but 25 Sqmm 3.5 core
180
-
-
All as per item No 07 (here-in-before) but 35 Sqmm 3.5 core
250
-
-
All as per item No 07 (here-in-before) but 50 Sqmm 3.5 core
250
-
-
All as per item No 07 (here-in-before) but 70 Sqmm 3.5 core
200
-
-
All as per item No 07 (here-in-before) but 95 Sqmm 3.5 core
200
-
-
All as per item No 07 (here-in-before) but 120 Sqmm 3.5 core
180
-
-
All as per item No 07 (here-in-before) but 150 Sqmm 3.5 core
100
-
-
All as per item No 07 (here-in-before) but 240 Sqmm 3.5 core
150
-
-
M&L for replacement of heat shrinkable end termination cable jointing kit for PVC/XLPE insulated ,armoured electric cable of size 25 to 50 Sqmm 3.5 core 1100 Volts garde for indoor/outdoor use complete with jointing materials and accessories etc complete all as specified and directed.
15
-
-
All as per item No 17 (here-in-before) but electric cable of size 70 sqmm to 120 Sqmm 3.5 core
10
-
-
All as per item No 17 (here-in-before) but electric cable of size 150 sqmm to 185 Sqmm 3.5 core
10
-
-
All as per item No 17 (here-in-before) but electric cable of size 240 sqmm to 300 sqmm 3.5 core
10
-
-
All as per item No 17 (here-in-before) but electric cable of size 400 sqmm sqmm 3.5 core
6
-
-
M& L for replacement of Cable lugs with copper alloy tubular bimetallic terminals of size 10 Sqmm incl crimping with help of crimping tools etc complete all as specified and directed.MAKE:-DOWELLS/JAINS SONS OR EQUIVALENT AS APPROVED BY GE
40
-
-
All as per item No 22 (here-in-before) but of size 16Sqmm
40
-
-
All as per item No 22 (here-in-before) but of size 25sqmm
40
-
-
All as per item No 22 (here-in-before) but of size 35Sqmm
40
-
-
All as per item No 22 (here-in-before) but of size 50 Sqmm
40
-
-
All as per item No 22 (here-in-before) but of size 70 Sqmm
40
-
-
All as per item No 22 (here-in-before) but of size 95 Sqmm to 120 sqmm
60
-
-
M& L for replacement of Cable lugs with aluminium alloy tubular bimetallic terminals of size 25 Sqmm incl crimping with help of crimping tools etc complete all as specified and directed.MAKE:-DOWELLS/JAINS SONS OR EQUIVALENT AS APPROVED BY GE
50
-
-
All as per item No 29 (here-in-before) but of size 35Sqmm
80
-
-
All as per item No 29 (here-in-before) but of size 50 Sqmm
80
-
-
All as per item No 29 (here-in-before) but of size 70 Sqmm
80
-
-
All as per item No 29 (here-in-before) but of size 95 Sqmm
50
-
-
All as per item No 29 (here-in-before) but of size 120 Sqmm
50
-
-
All as per item No 29 (here-in-before) but of size 150 Sqmm
50
-
-
All as per item No 29 (here-in-before) but of size 185 Sqmm
50
-
-
All as per item No 29 (here-in-before) but of size 240 Sqmm
50
-
-
All as per item No 29 (here-in-before) but of size 300 Sqmm
30
-
-
All as per item No 29 (here-in-before) but of size 400 Sqmm
30
-
-
M & L for galvanised steel tubing 40 mm bore light grade laid in trenches, road crossings pole/wall etc. for cable protection including providing MS flat iron 50mm x 6mm clamps (02 Nos) complete all as specified and directed including taking down the existing UNSV steel tubing etc complete all as specified and directed.
30
-
-
All as per item No 40 (here-in-before) but 50mm dia.
42
-
-
All as per item No 40 (here-in-before) but 80mm dia.
48
-
-
M&L for Boring of holes under road / Cutting of roads for passing cable including make good damaged surface with cement concrete 1:4:8 type D2 ( using 40mm graded stone aggregate)/black bitumin carpet etc complete all as specified and directed.
5
-
-
Dismantling steel poles/struts, any size etc complete all as specified and directed.
5
-
-
Dismantling cross -arms of MS channel or angle sections etc complete and setting aside for re-use with in 50 mtr.
2
-
-
Dismantling insulators any type, any size etc complete all as specified and directed.
85
-
-
Dismantling stay assembly complete (demolition of concrete, etc. and excavation measured separately etc complete all as specified and directed.
5
-
-
Dismantling overhead ACSR conductor (steel reinforced) of any size from LT OH Lines from existing electric pole complete as specified and directed.
2.8
-
-
Dismantling earth wire or cradle guard of any type any size complete all as specified and directed.
1
-
-
Supply, install, test and commission out door type feeder pillar boxes 600mmx600mmx500mm (Bus bar chamber) with aluminium bus bar 400 amps - 04 Nos fixed over epoxy insulators and outer shell made out of 3.15 mm thick MS sheet supported with MS angle section 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform 90 cm above and 45 cm below the ground level, frame factory fabricated with front openable single door ( door hinged with body at 2 places with hinges ) lockable/open able by Keys having chromium plated 19 mm dia fancy lock, “U” type gasket shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, tested at factory approved from CPRI for 35 MVA rupturing capacity at 415 Volts factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:8623/93, etc complete all as specified and directed.
9
-
-
M & L for repair/maint of LT panel board by dismantling all cable connection i.e incoming and outgoings and trenching out cable / cable loop after digging, cutting burnt portion of cable, cleaning and fixing of lugs with crimping tool, cleaning of bus bar with emery paper, tightening of bus bar , re-fixing of cable with busbars/circuit breaker, by providing new bolts, nuts and washers cable lugs to be provided for all incoming and outgoing cables etc complete all as specified and directed.
43
-
-
Supply, installation, commissoning and testing of LT panel board, CPRI approved, kiosk type outdoor type, LT (415 volts, 50 Hz, 3 Phase with neutral, 4 wire supply), floor mounted, factory assembled, weather and vermin proof ( Protection Class IP-54), made out of 3.15 mm thick MS CRCA sheet of suitable size required for incomming and outgoings with front & rear opening doors duly hinged upto full door height with special steel hinges, rubber lining, bakelite sheet, locking arrangements, steel tower bolt both side of the doors, powder coated internally and externally, CRCA sheet for panel shall be mounted on 50mmx 50mm x 5mm angle iron frame and shall have channel base of appropriate size and mounted on PCC foundation built in PCC 1:3:6 type C-2 be using 40mm graded crushed stone aggregate including earthwork complete , platform height of the panel at least 2 feet from the ground level as recommended or directed by the Engineer in charge comprising of following.
INCOMING
(a) TPN Copper bus bar 1000 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators not less than 1.0 mtr long (b) MCCB 630 Amps 4 pole, 415 volts, adjustable thermal and fixed magnetic release with rupturing capacity 36 KA-01 No
(c) Voltmeter digital type 0-500Amps with in built selector switch-01 No
(d) Ammeter digital type 0-600 Amps with suitable size of CTs and inbuilt selector switch -01 No
(e) Phase indicator lamp neon type RYB (set of three)-01 set
2
-
-
OUT GOING
(a) MCCB 200 Amps 4 pole 415 Volts, adjustable thermal and fixed magnetic release with rupturing capacity 16 KA.-02 No
(b) MCCB 160 Amps 4 pole 415 Volts,adjustable thermal and fixed magnetic release with rupturing capacity 16 KA.-02 Nos
(c) MCCB 100 Amps, 3 pole 415 volts adjustable thermal and fixed magnetic release with rupturing capacity 10 KA - 02 No
(d) Two spare cabinet for accomadating MCCB 63 Amps for future expansion.
Note. (i) The quoted rate shall includes minor items such as lugs,Spreader links, nuts & bolts, washers, top insulators, sleeves, provision of extra holes in bus bar etc.
(ii) All internal wiring shall be done with suitable size of PVC insulated solid copper conductor FRLSH cable conforming to IS-694.
-
-
-
Supply, installation, commissoning and testing of LT panel board, CPRI approved, kiosk type outdoor type, LT (415 volts, 50 Hz, 3 Phase with neutral, 4 wire supply), floor mounted, factory assembled, weather and vermin proof ( Protection Class IP-54), made out of 3.154 mm thick MS CRCA sheet of suitable size required for incomming and outgoings with front & rear opening doors duly hinged upto full door height with special steel hinges, rubber lining, bakelite sheet, locking arrangements, steel tower bolt both side of the doors, powder coated internally and externally, CRCA sheet for panel shall be mounted on 50mmx 50mm x 5mm angle iron frame and shall have channel base of appropriate size and mounted on PCC foundation built in PCC 1:3:6 type C-2 be using 40mm graded crushed stone aggregate including earthwork complete , platform height of the panel at least 2 feet from the ground level as recommended or directed by the Engineer in charge comprising of following.
INCOMING
(a) TPN Copper bus bar 630 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators not less than 1.0 mtr long (b) MCCB 400 Amps 4 pole, 415 volts, adjustable thermal and fixed magnetic release with rupturing capacity 36 KA-01 No
(c) Voltmeter digital type 0-500Amps with in built selector switch-01 No
(d) Ammeter digital type 0-400 Amps with suitable size of CTs and inbuilt selector switch -01 No
(e) Phase indicator lamp neon type RYB (set of three)-01 set
4
-
-
OUT GOING
(a) MCCB 400 Amps 4 pole 415 Volts, adjustable thermal and fixed magnetic release with rupturing capacity 36 KA.-01No
(b) MCCB 200 Amps 4 pole 415 Volts, adjustable thermal and fixed magnetic release with rupturing capacity 16 KA.-01 Nos
(c) Two spare cabinet for accomadating MCCB 200 to 63 Amps for future expansion.
Note. (i) The quoted rate shall includes minor items such as lugs, nuts & bolts, washers, top insulators, sleeves, provision of extra holes in bus bar etc
(ii) All internal wiring shall be done with suitable size of PVC insulated solid copper conductor FRLSH cable conforming to IS-694..
-
-
-
M & L for Earthing complete with galvanized steel earth plate 60cm x 60cm x 6mm thick electrode, burried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to GI strip 32 x 6mm size up to test point by means of nuts, bolts, check nuts and washers of GI including excavation and earth work, PCC 1:3:6 type C-1 pit, 20mm bore dia GI pipe, medium grade pipe for watering arrangement and 15mm bore dia GI pipe, light grade for protection of earth wire, 50mm thick RCC 1:2:4 type B-1 cover reinforced with 8mm dia TMT bars @ 15cm C/C both ways and with handle made out of 10mm dia bars, funnel, wire mesh etc. as shown in electrical Plate No. 03 of SSR Part-I connected to earthing test point including taking down old unserviceable material and testing on completion complete all as specified and as directed.
6
-
-
M & L for Replacement of unserviceable MCCB 4 Pole, 415 V, Adjustable type, 160 Amps , 36 KA , AC 415 Volts complete all as specified and directed. including dismentling the existing with all connections & fixing the new with all connections using spreader link all as directed by Engg-in-charge.
3
-
-
M & L for Replacement of unserviceable MCCB 4 Pole, 415 V, Adjustable type, 200 Amps , 36 KA , AC 415 Volts complete all as specified and directed. including dismentling the existing with all connections & fixing the new with all connections using spreader link all as directed by Engg-in-charge.
4
-
-
M & L for Replacement of unserviceable MCCB 4 Pole, 415 V, Adjustable type, 250 Amps , 36 KA , AC 415 Volts complete all as specified and directed. including dismentling the existing with all connections & fixing the new with all connections using spreader link all as directed by Engg-in-charge.
3
-
-
M & L for Replacement of unserviceable MCCB 4 Pole, 415 V, Adjustable type, 400 Amps , 36 KA , AC 415 Volts complete all as specified and directed. including dismentling the existing with all connections & fixing the new with all connections using spreader link all as directed by Engg-in-charge.
4
-
-
M & L for Replacement of unserviceable MCCB 4 Pole, 415 V, Adjustable type, 630 Amps , 50 KA , AC 415 Volts complete all as specified and directed. including dismentling the existing with all connections & fixing the new with all connections using spreader link all as directed by Engg-in-charge.
2
-
-
Labour for laying,spreading and leveling graded coarse aggregate all as directed by Engineer-in -Charge
15
-
-
Demolition and breaking up drain pipes(salt glazed,stoneware, AC or reinforced concrete) set in cement 'mortar 150 mm dia fixed in position etc complete all as specified and directed.
100
-
-
Demolition of cement concrete in ground floors and pavings n.exc 15 cm thick above or below ground level etc complete all as specified and directed.
1
-
-
Demolition of brick work built in cement mortar or cement lime mortar including all quoins, arches etc complete all as specified and directed.
2
-
-
Demolition of reinforced cement concrete in ground floors and pavings n.exc 15 cm thick above or below ground level etc complete all as specified and directed.(Reinorcement cut as required to facilitate demolition)
0.1
-
-
Taking down cement plaster and raking out joints, hacking for key,scrubbing down with water built in cement mortar etc complete all as specified and directed.
50
-
-
Demolition of laid bedded and pointed in any mortar Stone slabs and tiles of any description or thickness in floors, aprons etc complete all as specified and directed.
10.1
-
-
M&L for Concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested in cement concreet 1:3:6 type c2 etc complete all as specified and directed.
100
-
-
DWCPE (SN8) 180 (OD)/163(ID) mm diameter Pipes laid on 150 mm thick bed with excavation depth( 0.70m – 1.65 m) in any type of soil, including manholes/drop manhole of standard size made of Brick masonry/ RCC/Precast RCC with SFRC ventilating cover and frame. Includes all items and activities to execute and make sewer line functional etc complete all as specified and directed.
100
-
-
Supply & fix in repair PVC (SWR) pipes single socketed in any length with rubber ring joints,but bore of pipe 150 mm dia laid in trenches or floors etc complete all as specified and directed.
10
-
-
Supply & fix in repair PVC (SWR) pipes single socketed in any length with rubber ring joints,but bore of pipe 110mm dia fixed to walls etc complete all as specified and directed.
10
-
-
Supply and fixing as in replacement 100mm dia grating doom with waste hole of PTMT (minimum weight 25gms) complete all as specified and as directed by the Engr-in-Charge.
4
-
-
All as per item No 71 (here-in-before) but bore of pipe 110 mm dia .
10
-
-
All as per item No 72 (here-in-before) but bore of pipe 75 mm dia .
10
-
-
Supply and fixing in repair 110/150 mm bore stack clamps out of 25mm by 3mm flat iron and round iron stays, including bolts and nuts and securing ends of stays to wall or roof for nominal bore etc complete all as specified and directed.
4
-
-
S & F in repair PVC (SWR) bends any radius 110 mm dia etc complete all as specified and directed.
5
-
-
S & F in repair PVC (SWR) bends any radius 75 mm dia
5
-
-
S & F in repair 110mm dia PVC (SWR) branch piece, single (single Y equal or unequal) etc complete all as specified and directed.
5
-
-
All as per item No 77 (here-in-before) but bore of pipe 75 mm dia.
4
-
-
S & F in repair 75mm dia, PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed.
3
-
-
S & F in repair PVC Gully trap 125/110mm, setting and jointing with solvent cement etc complete all as specified and directed.
6
-
-
Material and labour for brick work in cement mortar1:6 with sub class `B' bricks straight or curved on plan exceeding 6m mean radius etc complete all as specified and directed.
2
-
-
M&L for brick work with sub class 'B' bricks straight or curved on plan in any radius in half brick thick walls built in cement mortar 1:4, etc etc complete all as specified and directed.
20
-
-
M & L for rendering in 10 mm thick in cement mortar1:6 onfair faces of brick work, finished even and smooth without using extracement complete all asspecified.
10
-
-
M&L for cement concrete (1:2:4) type B1 (using 20 mm graded stone aggregate) as in copings including necessary formwork etc complete all as specified and directed.
1
-
-
Material and labour for deformed steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking endsand binding with mild steelwire (annealed) n.less than 0.9mm dia etc complete all as specified and directed.
50
-
-
All as per item No 85 (here-in-before) but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders .
50
-
-
M & L for precast RCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in manhole cover set in CM 1:4 including necessary form work etc complete all as specified and directed..
5
-
-
M&L for plain cement cement concrete (1:5:10) type E-2 using 40mm graded stone aggregate as in foundation filling and mass concrete etc complete all as specified and directed..
3
-
-
M&L for cement concrete (1:3:6) type C-2 using 20 mm graded stone aggregatre as in surface channels and drains including necessary form work complete.
2
-
-
M&L for 75 mm thick PCC (1:3:6) type C-2 , (using 40 mm graded stone aggregate)as in plinth protection/aprons/path laid to slope of 1:12, finished fair and even without using extra cement with and including all necessary formwork to divide tha area in panels, finishing exposed edges fair or rounding or chamfering where directed and providing 10 mm wide joints throughout thickness of plinth protection duly filled with mastic filling (one part of hot bitumen 85/25 and three part of fine sand by weight) etc complete all as specified and as directed.
30
-
-
M&L for Extra for forming fair finished surfaces of drain or channels, innergirth 30 cms, using extra cement including forms, moulds mitred/ stoppedends etc complete all as specified and directed.
50
-
-
Cleaning of Blockage IWC,EWC, Wash basin, gully trap, floor trap etc either by hand pump or by rodding or by any other means untill clear flow is observed all as specified and as directed by Engr in charge.
400
-
-
Carrying out opening of manholes,sewer line of any type and any depth removing the sludge/solid content from the manhole/sewer line by manual/ mechanical method and also cleaning the sewage line of any dia and at any depth either by water pressure or by any other flushing or roding and other suitable means at the discretion of the contractor at his own arrangements so as to remove the blockage and making the sewer lines and manhole fully functional to the entire satisfaction of Engineer-in-Charge also to remove the sludge/solid contents out of defence land including covering with a layer of earth and repositioning of the RCC/CI cover slab all as directed by the Engineer-in-Charge in SW Zone under. The complaint shall be cleared/rectified to the complete satisfaction of Engineer-in-Charge .
500
-
-
Desilting of septic tank/soakage pit of any size, type and any depth and removing the sludge/solid content from the septic tank/soakage pit by manual/ mechanical method or any other suitable means at the discretion of the contractor at his own arrangements and make the septic tank/soakage pit fully functional to the entire satisfaction of Engineer-in-Charge also to remove the sludge/solid contents out of defence land including covering with a layer of earth and repositioning of the RCC/CI cover slab all as directed by the Engineer-in-Charge in Sw Zone.
100
-
-
Cutting into exisiting manholes for connecting new drains, making good topipes and rendering ,cutting out existing benching and forming branch channel, halfround or 3/4 section in cement concrete1:2:4 type B smooth finished and reforming benching as required, internal dia of pipe150mm etc complete all as specified and directed.
50
-
-
Excavating in trenches not exceeding 1.5m wide and n.exceeding 1.5m in depth; for foundation , etc not exceeding 10sq.m on plan and not exceeding 1.5m in depth and gettingout insoft/ loose soil all as specifed.
5
-
-
Excavation over areas, n.exc 1.5m deep,and getting out for foundation, etc. soft/loose soil etc complete all as specified and directed.
5
-
-
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm In soft/ loose soil etc complete all as specified and directed.
4
-
-
Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point,in soils.
2
-
-
S&F in repairs vitreous china water closet (squatt pan) orrisa pattern 580x440 mm size pan white with front or back inlet with integral 'foot rests including provn of lime concrete bedding including connections to 'flushing cistern/pipe complete all as specified and directed including 100mm CI 'P' trap.
4
-
-
Supply and fixing as in replacement vitreous China wash down water closet pan (pedestal pattern) 110mm dia bore with ‘P’ or ‘S’ trap, front or back inlet, fixing bolts, with coloured PVC seat cover etc complete all as specified and directed.
Make: Parryware Cat No C0278 for water closet, Cat No C8071 EWC Standard for PVC seat cover or equivalent approved make.
2
-
-
M&L Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc complete all as specified and directed.
30
-
-
M&L for Brushing neat cement slurry with 3.0 Kg of cement per Sq meter etc complete all as specified and directed.
30
-
-
Material and labour for non skid ceramic coloured tiles 7 to 8mm thick (Square/rectangular) area of each tile exc 0.06 sqm but n.exc 0.11 sqm coloured in floor etc set and jointed in neat cement slurry and pointed in white cement with pigment to match the shade of tiles laid over and including 15mm thick screed bed in CM (1:4) etc complete all as specified and directed.
100
-
-
Material and labour for non skid ceramic coloured tiles 7 to 8mm thick (Square/rectangular) area of each tile exc 0.11 sqm but n.exc 0.18 sqm coloured in floor etc set and jointed in neat cement slurry and pointed in white cement with pigment to match the shade of tiles laid over and including 15mm thick screed bed in CM (1:4) etc complete all as specified and directed.
50
-
-
Material and labour for glazed ceramic coloured tiles of size 300x200x7mm thick as on vertical surfaces, set and jointed in neat cement slurry and pointed in white cement with pigment to match with the shade of tiles laid over and including 10mm thick cement plaster in CM (1:4) etc complete all as specified and directed.