Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_675950_1Bid Award Id
ViewTender No
8978/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supply only Anti pumping device complete all as specified and as directed.
3
-
-
Supply only Worm wheel with work shaft suitable for HT VCB complete all as specified and as directed.
4
-
-
Supply only HRC fuse of existing capacity complete all as specified and as directed.
10
-
-
Supply only voltmeter complete all as specified and as directed.
4
-
-
Supply only Ammeter complete all as specified and as directed.
6
-
-
Supply only under over voltage relay CGV 24C complete all as specified and as directed.
5
-
-
Supply only TNC switch complete all as specified and as directed.
3
-
-
Supply only trip circuit healthy push button complete all as specified and as directed.
4
-
-
Supply only ZZ limit switch complete all as specified and as directed.
3
-
-
Supply only differential relay REF 615 complete all as specified and as directed.
5
-
-
Supply only of set of isolating contact assy 630A complete all as specified and as directed.
2
-
-
Supply only of UPPER SUPPORT - 450025001 complete all as specified and as directed.
1
-
-
Supply only of LOWER SUPPORT complete all as specified and as directed.
2
-
-
Supply only of SPOUT BUSHING UP TO 1250A (1 SET-6 NOS) - 450088057 complete all as specified and as directed.
1
-
-
Supply only of SET OF 3 Nos. SPOUT BUSHING WITH CC PARTS (Contact Plug) UPPER 630/800 AMP complete all as specified and as directed.
3
-
-
Supply only of SET OF 3 Nos. SPOUT BUSHING WITH CC PARTS (Contact Plug) LOWER 630/800AMP complete all as specified and as directed.
2
-
-
Supply only of SPOUT BUSHING WITH CC PART FOR "R" ,"Y" & "B" PHASE LOWER 630A/800A complete all as specified and as directed.
2
-
-
Supply only of SPOUT BUSHING WITH CC PARTS UPPER 1600 AMP - UNIVAC- (SET OF 3 Nos) 450088032 + 450V5512Q complete all as specified and as directed.
3
-
-
Supply only of Emergency Push to Trip assembly for PANEL (Ref.- W.O. V6921) - TRIP CABLE complete all as specified and as directed.
2
-
-
Supply only of VI (3" Dia) Type WL 34599 M3+ complete all as specified and as directed.
1
-
-
Supply only of VI (4"Dia) Type VL 33379 -109 complete all as specified and as directed.
1
-
-
Supply only of MOTOR & GEAR ASLY 110V AC/DC UMG 14 TYPE (DELCO MAKE PMR-5) complete all as specified and as directed.
2
-
-
Supply only of HOLDING CATCH ASSEMBLY complete all as specified and as directed.
4
-
-
Supply only of PUSH BUTTON BRACKET ASSEMBLY complete all as specified and as directed.
3
-
-
Supply only of CHARGED/DISCHARGED INDICATOR ASSEMBLY complete all as specified and as directed.
2
-
-
Supply only of MOTOR CHARGED MECHANISM ASLY UMG-14 WITH MOTOR & OPERATING COILS (Single Trip)-- UPTO 26.3KA complete all as specified and as directed.
4
-
-
Supply only of MOTOR CHARGED MECHANISM ASLY WITH DELCO MOTOR & OPERATING COILS { SUITABLE FOR 40KA NEW VCB's- BENCHMARK MECHANISM} complete all as specified and as directed.
3
-
-
Supply only of SPRING CHARGING HANDLE FOR HAND OPERATING complete all as specified and as directed.
3
-
-
Supply only of CLOSING SPRING ASSEMBLY complete all as specified and as directed.
2
-
-
Supply only of TRIPPING SPRING ASSEMBLY-450171005 (1SET-2NOS) complete all as specified and as directed.
3
-
-
Supply only of BREAKER POSITIONING LEVER WITH VCB FREE TO CLOSE/TRIP KNOB (ROLLER CAM SWITCH WITH RED KNOB 2 N/O) complete all as specified and as directed.
2
-
-
Supply only of Motor Bracket for Hand charge complete all as specified and as directed.
2
-
-
Supply only of Upper Terminal Plate Square (12mm Thick) complete all as specified and as directed.
2
-
-
Supply only of Lower Terminal Plate Square (12mm Thick) complete all as specified and as directed.
1
-
-
Supply only of POWER PACK (INPUT-230 VAC - OUTPUT-24 VDC) complete all as specified and as directed.
1
-
-
Supply only of 11kV INDOOR PT PRIMARY FUSE (3.15A) complete all as specified and as directed.
2
-
-
Supply only of BUTTERFLY SWITCH FOR MOTOR CUT-OFF complete all as specified and as directed.
2
-
-
Supply only of TIMER FOR MOTOR complete all as specified and as directed.
3
-
-
Supply only of TEST SERVICE LIMIT SWITCH complete all as specified and as directed.
4
-
-
Supply only of LED LAMP-RED, of SAP Code : 460232452D complete all as specified and as directed.
6
-
-
Supply only of LED LAMP-GREEN of SAP Code 460232453D complete all as specified and as directed.
4
-
-
Supply only of LED LAMP-BLUE of SAP code 460232456D complete all as specified and as directed.
5
-
-
Supply only of LED LAMP-AMBER of SAP Code 460232454D complete all as specified and as directed.
3
-
-
Supply only of LED LAMP-WHITE of SAP Code 460232457D complete all as specified and as directed.
3
-
-
Supply only of LED LAMP-YELLOW of SAP Code 460232460D complete all as specified and as directed.
3
-
-
Supply only 11 KV Current Transformer IS-2705, current ratio 100/5+5 Amp, rated frequency 50 Hz, STC 18.4 KA for 1 Sec, indoor type complete all as specified and as directed.
1
-
-
Material and Labour for decarbonsing/cleaning the cable compartment of Ring Main Unit 3 Way, 11 KV, consists of End joints,Current transformers, cable boots, bushings, by opening compartment cover by carefully switching off the main input cable supply and necessary switching ON of Earth switch of RMU thereby inspecting the end joints, current transformer, bushings and cable boots, checking the bushings for any flash overs/tracks, applying Becktol red solution to the bushings having moderate tracking, applying suitable HT insulated tape over anti tracking tube to prevent further tracking on, cleaning of end joints, CTs & cable boots with CTC and ensure proper decarbonisation and re-assembling complete all as directed by Engineer-in-Charge.
Note: The spare parts reqd for repair/replacement shall be measured and paid as supply only under relavant items and fixing of the same is deemed to be inclusive in this Item.
12
-
-
Supply only Contactor RT - 24VDC, suitable for RMU 11 KV including necessary electrical and mechanical connection complete all as specified and as directed.
4
-
-
Supply only Close Push button, suitable for RMU 11 KV, ncluding necessary electrical and mechanical connection complete all as specified and as directed.
4
-
-
Supply only Open push button, suitable for RMU 11 KV, ncluding necessary electrical and mechanical connection complete all as specified and as directed.
4
-
-
Supply only Operating handle Standard, suitable for RMU 11 KV, ncluding necessary electrical and mechanical connection complete all as specified and as directed.
3
-
-
M & L for repair of battery bank float cum booster charger by filling up distilled water in lead acid battery, cleaning of battery terminal, including repairing variable type rotary transformers (automatic battery charging system) suitable for input of 230 Volts AC 50 Hz single phase and having adjustable charging rate up to 100 AH at 110 V DC complete as specified and directed. Note : Batteries shall be measured & paid separetly under respective item of this schedule.
Note: The batteries reqd for repair/replacement shall be measured and paid as supply only under relavant item and fixing of the same is deemed to be inclusive in this Item.
1
-
-
Supply only 2 Volts 100 AH new maintenance free batteries dry type complete all as specified and directed.
55
-
-
M&L for Servicing & Repairs to Air-break switch (isolator) off load, rotating type, 33 KV, 800 Amps to 1250 Amps capacity, with proper alignment of isolator rotating blades, with fixed contact jaws, arcing horns, applying petroleum jelly to moving mechanism, cleaning and lubricating to isolator gear box assembly, tightening all nuts, bolts and clamps of jumpers etc, repairing to isolator gear box assembly and making in proper serviceable condition for smooth functioning, testing and commissioning on load complete all as specified and directed.
20
-
-
Supply, Lay of cable 1100 volts with PVC insulated and steel armoured with multi stranded copper conductor of the sizes 16 core 2.5 Sq mm complete all as specified and as directed.
110
-
-
Supply & Fix in replacement of Gasket for upto 3 MVA transformer (SRC RC 70C Grade) with including all required T&P for drain out and refilling transformer oil after proper filteration, comminissioning and testing complete complete all as directed.
2
-
-
Supply installing testing and commissioning in replacement the relay module Micom P111 making necessary cutting in the existing panel and necessary control wiring FRLS of size not less than 2.5 Sqmm and providing Ferules for identification and necessary spares for fixing complete to the entire satisfaction of the Engr-in-Charge.
1
-
-
M&L for Preparation of old painted inner/outer surfaces of indoor/out door HT/LT panels, through spray painting with two coat of synthetic enamel paint (RAL 7032) simens grey to achive smooth finish including writing of SM/MES No complete all as directed.
10
-
-
Supply and fix in repairs of Alarm annucator 12 window of model MBAS-0600 suitable for 33/11KV HT breaker complete all specified and directed.
1
-
-
Maint and servicing of APFC pannels of capicity 640 KVAR 11 KV online and their components, cleaning complete with blower and removing of deposited carbon particals from the terminals, adjusting relays and other parts up to certain limit as required including taking down old U/S parts and Accesories and calibrated as all as specified and directed.
Note: The spare parts reqd for repair/replacement shall be measured and paid as supply only under relavant item and fixing of the same is deemed to be inclusive in this Item.
4
-
-
Supply only high voltage HRC fuse of 100 Amps for capacitor bank complete all as specified and as directed.
3
-
-
Supply only high voltage HRC of 200 Amps fuse for capacitor bank complete all as specified and as directed.
3
-
-
Material & Labour for spreading and levelling of coarse graded stone aggregate (broken stone or boulders) of size 40 mm in sub - station yard to cover the complete area complete all as specified and as directed.
60
-
-
Removal of unwanted grass, plants and vegetations from E/M installations on Monthly basis for entire contract period including surface dressing and removal of grass ,plants and vegetations from site not less than 50mtr from starting point complete all as specified and directed
30
-
-
Material and labour for HT 11 KV (Earthed) grade heat shrinkable end termination jointing kit outdoor type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sqmm complete all as specified and as directed.
10
-
-
Material and labour for HT 11 KV (Earthed) grade heat shrinkable straight through jointing kit complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sqmm complete all as specified and as directed.
3
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements