Military Engineer Services Tender

View complete overview of Nagaland MES Tender

Military Engineer Services - MES Tender

Works
Paints and Enamels
Electrical and Electronics
Electrical Works
Eprocure
Opening Date17 Apr 2024
Closing Date6 May 2024
Tender Amount₹ 40,00,000 
Notes
Download

Costs

Summary

Repair Maint Of Old Lt Oh Lines Ug Cables Mccbs Lt Poles Painting With All Accessories In Ne Zone At Rms

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M & L for dry Sand cushioning in trenches for protection of cable including watering and consolidation etc complete all as specified and as directed. Note: Punned thickness shall be considerd for measurment purpose

48.6

-

-

... More
M & L for well burnt brick sub class B old size laying in trenches perpendicular to axis of the cable for protection of electric cable etc complete all as specified and as directed.

4800

-

-

... More
Supply & laying GI tubing 'light grade' galvanised, with all fittings, fixed to walls, poles, ceilings complete for protection of cables of size 40 mm dia bore including taking out unsv GI tubing etc complete all as specified and as directed. Make:- Jindal/TATA/Prakash surya

120

-

-

... More
Supply and laying or fixing or passing through pipe, LT XLPE insulated armured heavy duty cable 1100 volt grade ISI marked with aluminium conductor multi stranded cross sectional area 10 sq mm 2 core etc complete all as specified and as directed.

800

-

-

... More
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium stranded conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed with nominal cross sectional area 6 sq. mm 2 core etc complete all as specified and as directed. Note:- (i) all connections are uniformally dressed and connected/ jointing of cable with suitable size of lugs.

600

-

-

... More
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium stranded conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed with nominal cross sectional area 4 sq. mm 2 core etc complete all as specified and as directed.

600

-

-

... More
Supply and fixing two core FRLSH PVC insulated stranded aluminium conductor cable of size 2.5 sq mm, 1100 volts grade ISI marked etc complete all as specified and as directed.

500

-

-

... More
S&F in replacement of LED street light fitting driver ISI marked of capacity 60 Watt as per sample etc complete all as specified and as directed.

30

-

-

... More
S&F in replacement of LED street light fitting driver ISI marked of capacity 70 Watt as per sample etc complete all as specified and as directed.

25

-

-

... More
S&F in replacement of LED street light fitting driver ISI marked of capacity 90 Watt as per sample etc complete all as specified and as directed.

15

-

-

... More
S&F in replacement of LED street light fitting driver ISI marked of capacity 120 Watt as per sample etc complete all as specified and as directed.

15

-

-

... More
Supply and fixing in replacement of Rigid non-metallic PVC conduit 20mm medium grade ISI marked fixed to the pole by using suitable size of clamps, nuts bolts and washers for drawing of service connection wire for electric installation as per IS 9537 part 3 etc complete all as specified and as directed.

500

-

-

... More
S & F PVC street light junction boxes of size 380mmx225mmx140mm with front openable shutter and locking arrangement with onesuitable size rating 6-32 Amps MCB, mounted on dwin rail, connectors including fixing to pole with MS flat iron clamp 25mm x 3mm size with nuts and bolts washers, etc. complete including taking down unserviceable one etc complete all as specified and as directed.

60

-

-

... More
Material and labour for GI bracket for fixing of street light fitting , made out of 40 mm bore GI pipe,light grade of length not less than 1.20 mtr,45 degree bend to shape and fixed on pole with 2 Nos of FI clamps of 40x5 mm of suitable length fixed by means of bolts,nuts &washers including taking out old unsv bracket etc complete all as specified and as directed.

100

-

-

... More
Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing, heat resistant, corrosion resistantcomplete with driver, suitable size of bracket incl nuts, bolts, washers etc including thermal management in multiple optics with IP 65/66 protection complete. Including taking down old unsv light fittings etc complete all as specified and as directed.

105

-

-

... More
All as per item No 18 (here-in-before) but cap 70 watts.

90

-

-

... More
All as per item No 18 (here-in-before) but cap 90 watts.

49

-

-

... More
All as per item No 18 (here-in-before) but cap 35 watts.

54

-

-

... More
Material and labour in replacement of unsv LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics, environmental friendly,corrosion resistant, and equipped with IP66 protection complete with driver and lamp suitable for tower lights as application including openign and fixing of nuts, bolts and washers on existing high mast/tower/wksp structure properly etc complete all as specified and as directed.

35

-

-

... More
M & L for replacement of MCB SP-240 volt 6 Amp to 32 Amp 10 KA capacity having C-curve characteristics connected with suitable lugs etc complete all as specified and as directed.

60

-

-

... More
All as per item No 23 (here-in-before) but MCB SPN 32 Amp, 240 volts 10 KA.

25

-

-

... More
M & L for Steel tubular swaged poles Type 410-SP-31 (9 meter Long) including cast iron base plate finial tapper plug, bolts, cap, mild steel bolts, nuts and screws etc including applying two coats of black bituminous paint internally and externally up to planting depth and applying two coats of aluminium paints over acoat of aluminium primer (externally from top of PCC coping) confirming to IS 2713-1980 complete all as specified and as directed. (Earth work and concrete foundation shall be measured and paid separately under relevant items of Sch 'A') .

9

-

-

... More
M & L for PCC (1:3:6) type C-2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete for pole foundation etc complete all as specified and as directed.

4.57

-

-

... More
M & L for PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) as in coping including necessary use & waste of form work etc complete all as specified and as directed.

1.11

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.