Military Engineer Services Tender
View complete overview of Nagaland MES Tender
Costs
EMD
₹ 19,800Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_659965_1Bid Award Id
ViewTender No
8284/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
M & L for 15 mm thick rendering in cement mortar (1:4) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed
100
-
-
M&L for 15mm thick rendering in cement mortar (1:4), in two layers, under coat of 10 mm thick & top of 5 mm thick, to other than fair faces of brick or concrete wall surfaces, top layer 5 mm thick mixed with water proofing compound @ 3% by weight of cement or as per manufacture's instructions), finished even and smooth without using extra cement complete all as specified and as directed. Note : Water proofing compound will be measured and paid separately under relevant item of this schedule.
90
-
-
Supply only integral water proofing compound complete all as specified and as directed.
6.78
-
-
Demolition of plain cement concrete in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) complete all as specified and as directed.
0.5
-
-
M & L for PCC 1:2:4, type B1 (using 20 mm graded stone aggregate) as in coping, cills, hold fasts, fixing of post, water trough etc. including necessary formwork (straight or curved) complete all as specified and as directed.
0.5
-
-
Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
4
-
-
M & L for pre cast RCC cover slab, type B-1, 1:2:4 (Using 20 mm graded crushed stone aggregate ) as in manhole cover slab etc., and set in cement mortar 1:4 including necessary form work complete all as specified and as directed
4
-
-
M&L for RCC type 1:2:4 , type B-1 (using 20mm graded stone aggregate) as in Slabs supported on walls,sunshade, chajja, floors, roofs, landings, balconies etc. complete all as specified and as directed.
3
-
-
Use and waste of formwork to soffits and sides of suspended slabs such as roof slabs, floor slabs, landings sun shade, chajja, floors, roofs, landings, balconies etc., n exc 200 mm thick (horizontal or sloping) for fair finished surface of concrete complete all as specified and as directed.
25
-
-
Use and waste of formwork to edges of concrete flats, treads, breaks in floors, windows cills, concrete railings, openings in concrete walls, floor and roofs n.exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n. exc 20cm wide chajja not exceeding 10 cm wide in rough finished surfaces of concrete complete all as specified and as directed.
30
-
-
M & L for mild steel TMT bars 8 mm dia cut to length, bent to shape as required including cranking, bending spirally for hooping for columns,hooking ends and binding with mild steel wire(annealed) not less than 0.9mm dia as in reinforcement bar complete all as specified and as directed.
130
-
-
M & L for mild steel TMT bars 10 mm dia and over cut to length, bent to shape as required including cranking, bending spirally for hooping for columns,hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia as in reinforcement bar complete all as specified and as directed.
180
-
-
Cleaning of accumulated solid /semi solid liquid sludge from septic tank any size by mechanical pump with sewage collecting tank and collecting the sludge so removed in a container with mechanical transport for shifting to a distance exc 50 m distance and depositing in a shallow pit with a covering of loose/soft with of minimum 30 cm thick layer at an inhabitable location in the cantt areas as directed by Engr-in-Charge and sprinkling bleaching powder @ 01 kg per square metre for precaution of health hazard to the surrounding complete all as specified and as directed. Note: The unit quoted rate under this item shall deemed to be inclusive of bleaching powder, necessary earth work for earth pit for deposition of sludge etc)
215
-
-
Cleaning of manholes of depth from 1.0 m to 2.0 metre including de-sludging watering by mechanical pump solid, semi solid, flushing with water removing all sludge etc to a distance exc 50 m and buried in a shallow pit with a covering of soft/loose soil of minimum 30 cm thick layer and sprinkling bleaching powder @ 01 kg per square metre for precaution of health hazard to the surrounding complete all as specified and as directed.
Note: The unit quoted rate under this item shall deemed to be inclusive of bleaching powder, necessary earth work for earth pit for deposition of sludge etc
230
-
-
Cleaning of blockage sewage line manually and then with fresh water of pipe 100 mm dia / 150 mm dia in between man holes and passing rubber ball of suitable size through line to ensure all blockage perfectly clear to the entire satisfaction of Engineer-In-Charge complete all as specified and as directed.
300
-
-
De-sludging the solid sludge and depositing the wastage for cleaning aggregates obtained from soak well with new brick bats including using existing serviceable aggregates (minimum 50% for the purpose) including depositing the sludges/silt under trenches with minimum coverage 30cm earth on top, sprinkling bleaching powder @ 01 kg per square metre for precaution of health hazard to the surroundingcomplete all as specified and as directed.
Note: The unit quoted rate under this item shall deemed to be inclusive of bleaching powder, necessary earth work for earth pit for deposition of sludge etc
54
-
-
Cleaning / removal of blockage from Nahani trap, floor trap, gully trap, IWC, EWC including CI / PVC or any pipe complete all as specified and as directed.
450
-
-
Excavation in trenches not exc 1.50 m wide and not exc 1.50 m deep for foundation or for shafts, wells cesspits,man holes, laying of cable etc not exc 10 Sqm on plan and n exc 1.5m in depth and getting out in hard/dense soil complete all as specified and as directed.
15
-
-
Returning, filling, in soil including spreading, levelling, watering and well ramming in layers n.exc. 25cm thick complete all as specified and as directed.
3
-
-
Removing excavated soil to distance not exc. 50 m and depositing where directed at a level not exc. 1.5 m above the starting point etc complete all as specified and as directed.
12
-
-
S & F in repair 150 mm dia PVC (SWR) pipes, single socketed in any length with rubber ring joints laid in trenches as in waste / soil pipe complete all as specified and as directed.
28
-
-
S & F in repairs, 110 mm dia PVC (SWR) pipes, single socketed in any length with rubber ring joints laid in trenches complete all as specified and as directed.
50
-
-
M & L for concrete bed in cement concrete 1:3:6 type C-2 (using 40 mm graded stone aggregate) for drain pipes, 150 mm bore including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed.
20
-
-
M & L for concrete bed in cement concrete 1:3:6 type C-2 (using 40 mm graded stone aggregate) for drain pipes 110/100 mm bore including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed.
50
-
-
S & F in repair 75 mm dia PVC (SWR) pipes, single socketed in any length with rubber ring joints fixed to wall as in waste / soil pipe complete all as specified and as directed.
30
-
-
S&F stack clamps made out of 50 mmx 5 mm flat iron and 16 mm dia round iron stay including bolt and nut and securing ends of stay to wall or roof for 75 mm dia pipe complete all as specified and as directed.
7
-
-
S & F 110 mm dia PVC (SWR) junction, single, (single T) equal or unequal complete all as specified and directed.
7
-
-
S&F 110 mm dia PVC (SWR) reducer complete all as specified and directed.
7
-
-
S&F 110 mm dia PVC (SWR) bends with access door any radius complete all as specified and as directed
7
-
-
S&F 75 mm dia PVC (SWR) bends with access door any radius complete all as specified and as directed
7
-
-
S & F in repairs, Vitreous China Squatting Pan"Orissa pattern" size 580 mmx440 mm white with integral foot rest etc. ( excluding cistern and flush pipe) including S or P Trap and provision of concrete bedding and making good to floor complete all as specified and as directed.
7
-
-
M&L for Cutting into existing manholes for connecting new drains of 150 mm internal dia of pipe, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 smooth finished, and reforming benching as required complete all as specified and as directed.
6
-
-
M&L for Cutting into existing manholes for connecting new drains of 110 mm internal dia of pipe, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 smooth finished, and reforming benching as required complete all as specified and as directed.
6
-
-
Evaluation Notes How It Works ?