Military Engineer Services Tender

View complete overview of Nagaland MES Tender

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date18 Apr 2024
Closing Date7 May 2024
Tender Amount₹ 47,00,000 
Notes
Download

Costs

Summary

Repair Maint Of Air Conditioning Water Cooler At Rajbari Area Dimapur And Rms

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L for Switch Socket combination, 2 in 1, 5 pin 6A flush type etc complete all as specified and as directed.

15

-

-

... More
M&L for Switch Socket combination, 2 in 1, 5 pin 6A/16A flush type etc complete all as specified and as directed.

20

-

-

... More
Supply and fixing sub-main wiring with PVC insulated & unsheathed two run of 4.0 Sqmm single core multi stranded copper conductor cable (FRLSH) 1100 Volt grade along with one run of 4.0 Sqmm PVC insulated & Unsheathed copper conductor cable (FRLSH) 1100 Volt grade connected to common earth dolly as earth continuty conductor, drawn through 20 mm dia PVC Casing Caping after and inclduing taking down existing submain wiring complete all as specified and as directed.

40

-

-

... More
Supply and fixing sub-main wiring with PVC insulated & unsheathed two run of 6.0 Sqmm single core multi stranded copper conductor cable (FRLSH) 1100 Volt grade along with one run of 6.0 Sqmm PVC insulated & Unsheathed copper conductor cable (FRLSH) 1100 Volt grade connected to common earth dolly as earth continuty conductor, drawn through 20 mm dia PVC Casing Caping after and inclduing taking down existing submain wiring complete all as specified and as directed.

50

-

-

... More
M&L for MCB Distribution board double door type SPN 8 way sheet steel powder painted with bus bar neutral link & earth din rail, recessed with wall surfaces by chase cutting and making good disturbed surfaces of wall etc complete all as specified and as directed.

6

-

-

... More
M&L for MCB Distribution board double door type SPN 4 way sheet steel powder painted with bus bar neutral link & earth din rail, recessed with wall surfaces by chase cutting and making good disturbed surfaces of wall etc complete all as specified and as directed.

6

-

-

... More
S&F MCB Single pole 5 to 30 Amp, 10 kA, ISI Marked etc complete all as specified and as directed.

48

-

-

... More
S&F MCB SPN upto 40 Amp, 10 kA, ISI Marked etc complete all as specified and as directed.

12

-

-

... More
M& L for servicing of following Air Conditioners including inspecting ACs for standing pressure and find out type of gas used, dismantling the AC indoor unit, seperate the Grill, Air filter, PCB and use the protector cover for indoor unit and washing the cooling coil, condenser coil, air fillter,swing blade, fan blade, grill of outdoor unit by jet pressure including clean the all parts of indoor/ outdoor unit and dry the all parts with clean cloth and re-assembling the complete unit and re-installing in its original position and testing on completion of proper servicing complete all as directed by the Engineer-in- Charge.

-

-

-

... More
(a) Window type AC upto 2.0 TR capacity

120

-

-

... More
(b) Split type AC upto 2.0 TR capacity indoor and out door unit complete

240

-

-

... More
(c) Casette AC of 2 to 4.0 TR capacity indoor and out door unit complete .

24

-

-

... More
(d) Tower AC of capacity upto 3/4/8 TR indoor and out door unit complete.

16

-

-

... More
M & L for disconnect and remove unserviceable main PCB/ display PCB and Supply and fix new main PCB/ dispaly PCB suitable for existing model of following cooling appliances complete all as specified and as directed by the Engineer-in-Charge.

-

-

-

... More
(a) Window AC upto 2 TR

16

-

-

... More
(b) Split AC 2 TR

8

-

-

... More
(c) Split AC 1.5 TR

20

-

-

... More
(d) Casette AC of 4.0 TR Capacity

4

-

-

... More
(e) Tower AC of capacity upto 4 TR

4

-

-

... More
Taking out the unserviceable burnt fan motor from the following cooling appliances and supply and fix new fan motor suitable for existing model complete all as specified and directed by Engineer-in-Charge.

-

-

-

... More
(a) Window Air Conditioner of Capacity upto 2.0 TR.

22

-

-

... More
(b) Split Air Conditioner of Capacity upto 2.0 TR.

26

-

-

... More
(c) Casette/ Tower AC of capacity upto 4 TR

4

-

-

... More
Taking down unserviceable blower motor of split type air conditioner and supply and fix new blower motor including Blower suitable for existing model of indoor unit of split type air conditioner of capacity upto 2.0 TR including necessary connections and testing on completion complete all as specified and as directed by Engineer - in- Charge.

12

-

-

... More
Taking down unserviceable Swing motor of split type air conditioner and supply and fix new Swing motor suitable for existing model of indoor unit of split type air conditioner of capacity upto 2.0 TR including necessary connections and testing on completion complete all as specified and as directed by Engineer - in- Charge.

18

-

-

... More
Disconnect and remove unserviceable Spilt/Window AC compressor and supply and fix new sealed rotary / reciprocating compressor including brazing the suction / discharge lines suitable for existing model of following cooling appliances and testing on all as specified and directed by Engineer-in-Charge.

-

-

-

... More
(a) 1/1.5 TR window type/split type Air Conditioner.

9

-

-

... More
(b) 2.0 TR window type/split type Air Conditioner

6

-

-

... More
(c) 4TR Casette/ Tower type Air Conditioner

2

-

-

... More
Flushing and leak testing the complete system Spilt/Window AC and Water cooler with nitrogen gas and making good leaking portion by brazing and topping up compressor oil complete all as specified and as directed by Engineer in charge. Note: Cost of brazing and topping up of compressor oil is deemed to be included in quoted rate.

20

-

-

... More
Taking out unserviceable air filter and supply and fix new air filter cleanable, indigenous of suitable size for the window / split type air conditioners of capacity upto 4.0 TR complete all as specified and as directed by the Engineer-in-Charge.

8

-

-

... More
Taking out unserviceable condensor fan blades and supply and fix new condensor fan blades of existing/suitable model for the window type/out door unit of split type air conditioner of capacity upto 2.0 TR complete all as specified and as directed by Engineer-in Charge.

18

-

-

... More
Taking down old unserviceable thermal insulation and Supply and fix and new thermal insulating puff for suction and discharge copper tubes of split type air conditioner of capacity upto 4.0 TR, neatly tying the ends with PVC insulation tape complete all as specified and directed by Engineer- in Charge. Note Old insulation puff will be dumped at nearby dustbin.

30

-

-

... More
Filling the gaps between wall and refrigerant piping with white cement to prevent rodents entry and finishing smoothly to match with sorroundings etc complete all as specified and as directed.

25

-

-

... More
Supply and fix in replacment Window/ split AC remote upto 4 ton capacity as per sample etc complete all as specified and as directed.

20

-

-

... More
Taking down unserviceable condensing coil unit and supply and fix new condensing coil unit suitable for window / split type AC of capacity upto 2.0TR, as per the existing, etc complete all as specified and as directed.

4

-

-

... More
Pumping down the AC, taking carefully the indoor and outdoor units along with voltage stablizer of split type air conditioner of capacity upto 2.0 TR by disconnecting all electrical connections, suction and discharge lines from its installed position and shifting to another location, making hole into brick/stone wall & filling back with white cement where directed and installing the indoor and outdoor units alongwith stablizer at specified location and connecting all the electrical, suction and discharge lines, topping up the gas as required and testing on completion for proper functioning complete all as specified and directed by Engineer-in-Charge. (Note: Gas, Copper tube, Insulation puff, Connecting wire as required additional shall be measured seperately under relevant item).

40

-

-

... More
Taking down unserviceable plug and socket of any description, supply and fix single pole and neutral enclosure with two pin and earth plug and socket along with a 20 to 30Amps rated SP MCB, 230 volt, 50 HZ as required at site, etc complete all as specified and as directed.

30

-

-

... More
Supply and fix in replacment Window AC front grill capacity upto 2 ton as per existing sample etc complete all as specified and as directed.

25

-

-

... More
Checking the AC indoor unit for water leaks, cleaning the choked drain out pipe lines aligning with proper slope and fix the problem etc complete all as specified and as directed.

60

-

-

... More
Taking down unserviceable single pole contactor and M& L for single pole contactor for out door unit of Air conditioner of capacity up to 2.0 TR etc complete all as specified and as directed.

20

-

-

... More
Taking down Existing unserviceable Indoor assembly and Supply and fix new Indoor assembly of split type AC of Capacity upto 1.5/2.0 TR as per existing model or as approved by GE complete, connecting wires, copper lines and testing all as specified and any make as per site requited as directed by Engineer-in-charge. Note: Old Indoor assembly will be deposited in the AGE E/M store.

4

-

-

... More
Material and Labour for replacement of worn out window AC foundation frame, 0.75 Mtr height, frame work made out of angle iron 50 x 50x 3 mm, including cutting welding brazing soldering , including painting black colour ( two coats ) synthetic enamelled paint over a coat of red oxide primer etc and finishing, complete all as specified and as directed by Engineer-in-Charge.

2

-

-

... More
Taking down Existing unserviceable Outdoor unit assembly and Supply and fix new outdoor unit assembly of split type AC of Capacity upto 1.5/2.0 TR as per existing model or as approved by GE complete, connecting wires, copper lines and testing all as specified and any make as per site requited as directed by Engineer-in-charge. Note: Old Indoor assembly will be deposited in the AGE E/M store.

4

-

-

... More
Replacing of defective components/ accessories suitable for window/Split type AC of capacity 1.5/2 TR as required at site and directed by Engr-in-charge for the following:-

-

-

-

... More
(a) Running capacitor powder filled 50+2 MFD as approved (Make: Usha/Keltron/uptron/epcos ).

180

-

-

... More
(b) Starting capacitor powder filled 100/120 MFD as approved ( Make : Usha/Keltron/Uptron).

150

-

-

... More
(c) Capacitor for blower motor suitable for window type AC 6 MFD Make: Sriram/renutral/Usha

80

-

-

... More
(d) Over load protector for the window type AC 1.5/2 TR (Make : Sriram/renutral/Whrilpool)

50

-

-

... More
(e) Thermostat switch assembly suitable for window / split type AC of cap1.5/2 TR as approved ( Make : Renutral/Denfoss/Sriram/Cosmos )

45

-

-

... More
(f) Starting relay suitable for window / split type AC of cap 1.5/2 TR as approved ( Make : Sriram/ Renutral/Whrilpool)

30

-

-

... More
(g) Kiny form of size 1/4", 1/2", 5/8'' and 3/8''

60

-

-

... More
(k) Flair nut brass of size 1/4", 1/2", 5/8'' and 3/8''

40

-

-

... More
(l) Capilary tube of size 1/32" or as per sample

6

-

-

... More
(m) Copper tube of size 1/4'' with insulation matterials

120

-

-

... More
(n) Copper tube of size 1/2'' with insulation matterials

120

-

-

... More
Material and labour for replacement of condensed water drain pipe of length 5 Mtr for split type/ window AC complete including providing saddle with clamping arrangement (old unsv pipe dumped at nearly dustbin) etc complete all as specified and as directed.

100

-

-

... More
Material and labour for replacement of copper discharge tube of size 3/8" duly nylon insulated etc complete all as specified and as directed.

40

-

-

... More
Material and labour for replacement of copper suction tube of size 5/8" duly nylon insulated etc complete all as specified and as directed.

40

-

-

... More
M&L for for taking down unsv secondary PCB of indoor/outdoor unit of Three phase ACs capacity upto 4 Ton and suppy and fix new secondary PCB of existing make, complete all as specified and as directed.

4

-

-

... More
Material & labour for filling up & charging of R-22 refrigerant to the cooling appliances etc complete all as specified and as directed.

65

-

-

... More
Material & labour for filling up & charging of R-32 refrigerant to the cooling appliances etc complete all as specified and as directed.

40

-

-

... More
Material & labour for filling up & charging of R-134(A)/410 refrigerant to the cooling appliances etc complete all as specified and as directed.

20

-

-

... More
Material & labour for filling up & charging of R-410(A)/R-22 refrigerant to the cooling appliances etc complete all as specified and as directed.

25

-

-

... More
S & F Copper conductor, 6 sqmm 4 Core PVC insulated and sheathed multistrand cable etc complete all as specified and as directed.

100

-

-

... More
S&F wall mounted Stand suitable for fixing out door unit of split AC upto 2 Ton including all accessories etc complete all as specified and as directed.

20

-

-

... More
Replacement of unserviceable components/ parts such as power circuit board (PCB) time relay, socket outlet, regulators/toggle switch, voltmeter ,indicator lamp, circuit wiring fuse etc including rewinding of transformer & painting voltage stabilizer of cap upto 5 KVA etc complete all as specified and as directed.

40

-

-

... More
M&L for checking of Water cooler of any make / capacity in location and position at any site in AA RMS including necessary servicing i.e. making good electrical including copper terminal, cleaning , drain water system including replacement of hose clamp etc . complete , cleaning condensor , condenser fan motor , door gasket , cleaning storage water tank cleaning and testing for proper functioning ofwater cooler all as directed by Engr-in-Charge.( The rates are deemed to be included for maintaining complete and proper record of machine ie: make with srl no ,SM no. capacity, date of servicing , user signature after servicing , concerned JEs signature all as directed by Engineer in-charge )

180

-

-

... More
Disconnect and remove unserviceable water cooler compressor and supply and fix new sealed rotary / reciprocating compressor with built-in OLP, thermostat including brazing the suction / discharge lines suitable for existing model water cooler capacity upto 120 ltrs per hours, filling the gas and testing on all as specified and directed by Engineer - in - Charge. Make : Kirlosker/Tecumseh/ Sriram/ Voltas/Carrier.

20

-

-

... More
Disconnect and remove unserviceable over load protector and supply and fix new overload protector (OLP) suitable for Water cooler capacity of upto 120 Ltrs complete all as specified and directed by Engineer-in-Charge. (Make-Blue star, Godrej, Voltas)

22

-

-

... More
Material and Labour for replacement of copper filter and capillary tube of water cooler cooling capacity upto 60 Ltr/hrs, complete all as specified and as directed.

25

-

-

... More
Material and Labour for replacement of condensor fan motor as per sample HP-1/32, RPM-1300 suitable for water cooler having cooling cap upto 60 Ltr/hr with clips and motor fixing stand with fan bladeISI marked, complete all as specified and as directed.

22

-

-

... More
Material and Labour for replacement of condensor fan motor as per sample HP-1/16, RPM-1300 suitable for water cooler having cooling cap upto120 Ltr/hr with clips and motor fixing stand with fan blade ISI marked, complete all as specified and as directed.

15

-

-

... More
Material and Labour for Repalcement of thermostat switch with knob for water cooler, having cooling capacity 40/60/150 Ltrs/hr, complete all as specified and as directed. (Make : Rasnutrol/ Indfoss /Annapurna)

40

-

-

... More
Sunpply and fixing of 4.00 Sqmm 4 core multi stranded copper conductor cable (FRLSH) 1100 Volt grade drawn through 20/25 mm dia PVC Casing Caping after and inclduing taking down existing submain wiring complete all as specified and as directed.

100

-

-

... More
Material and Labour for replacement of drain PVC pipe, 25/ 32 mm bore for cooling cap upto 120 Ltr /Hrs 90 cms in length with two Nos mild steel clamps and necessary brass screws etc, (old drain PVC pipe dumped near by dustbin) etc complete all as specified and as directed.

20

-

-

... More
Material and Labour for replacement of SS drain water tray made out of 24 gauge stainless Steel sheet of size of 30x12x5 cm deep with necessary GI screws and PVC drain water connection arrangement of size not less than 25 mm dia, etc complete all as specified and as directed.

4

-

-

... More
Material and Labour for replacement of water storage tank top lid complete made out of 22 gauge mild steel sheet of existing shape and size for water cooler cap 80Ltrs., platic sheet of appropriate thickness on one side with door gaskit including , aluminium hinges 50 mm long 2/3 nos. and making good and painting with approved colour to match the existing colour, complete all as specified and as directed.

2

-

-

... More
Material and Labour for replacement of worn out bottom base of water cooler foundation frame made out of 1.6mm thick MS sheet for water cooler, & frame work made out of angle iron25x25x3 mm, including cutting welding brazing soldering , making holes for sealed unit , condenser with condensor fan motor , including painting black colour ( two coats ) synthetic enamelled paint over a coat of red oxide primer etc and finishing, etc complete all as specified and as directed.

2

-

-

... More
Taking out unserviceable push button tap and supply and fix new Self-closing taps, cast copper alloy, chro-mium plated, screwed of size 15 mm dia bore suitable for water cooler complete all as specified and directed by Engieer- in - Charge. Zoloto/Leader/HM/Shakti/Prayag.

15

-

-

... More
M&L for permanent type stiker of size 100x 50 mm having following details in letters not exceeding 15 mm, complete all as specified and as directed. (i) Machine Srl No______________. (ii) MES No___________________. (iii) Date set to work.____________. (iv) PRB Page No ______________. (v) Location___________________.

175

-

-

... More
Material and labour for painting to water cooler of storage cap. 150/120/80 Ltrs spray painting with two coats of synthetic enamelled paint (first quality) including preparation of surface, etc complete all as specified and as directed.

6

-

-

... More
Material and labour for PVC float valve 15 mm bore with PVC float, ball ISI marked complete with check nut/socket/GI nipple, complete all as specified and as directed. by Engineer-in-Charge Make: PRAYAG/ POLYTUFF/OR EQUIVALENT AS APPROVED BY GE

40

-

-

... More
Material and labour for replacement of aluminium fan blade for condenser fan motor (as per sample) suitable for water cooler having cooling capacity 60/150 Ltr/hrs water cooler, complete all as specified and as directed.

10

-

-

... More
Material and labour for replacement of condenser unit complete suitable for 40 Ltr/hrs cap. Water cooler including gas charging flushing out the system brazing, welding and jointing the suction reed and discharge reed complete all as per direction of Engineer-in-Charge

3

-

-

... More
Material and labour for replacement of condenser unit complete suitable for 60 to 120 Ltr/hrs cap. Water cooler including gas chargin flushing out the system brazing, welding and jointing the suction reed and discharge reed complete all as per direction of Engineer-in-Charge

3

-

-

... More
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 4 sq. mm nominal cross section in service connections etc complete all as specified and as directed.

120

-

-

... More
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 6 sq. mm nominal cross section in service connections etc complete all as specified and as directed.

100

-

-

... More
Attending day to day complaint to find out the fault of split ac, window ac, Casette ac and water cooler all as directed by Engr-in-charge.

400

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.