Indian Oil Corporation Limited Tender

View complete overview of Nagaland IOCL Tender

Indian Oil Corporation Limited - IOCL Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date9 Aug 2023
Closing Date29 Aug 2023
Tender Amount₹ 20,85,564 
Notes
Download

Costs

Summary

Construction And Commissioning Of Rain Water Harvesting System On Buildings And Sheds At Lpg Bottling Plant Dimapur Nagaland

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
PVC Downpipe (160 mm ): Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion, Single socketed pipes.

64.8

47948

739.95

... More
PVC Downpipe (110 mm ): Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion, Single socketed pipes.

102.48

28613

279.21

... More
75 mm Coupler: Providing & fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion.

18

1282

71.24

... More
110 mm Coupler: Providing & fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion.

70

7547

107.82

... More
87.5° Bend of 75 mm: Providing & fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion.

28

2303

82.27

... More
87.5° Bend of 110 mm: Providing & fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion.

73

8676

118.85

... More
Single tee with door of 75 x 75 x 75 mm: Providing & fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion.

11

1408

128

... More
Single tee with door of 110x 110 x 110 mm: Providing & fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion.

50

9304

186.08

... More
Pipe clips for 75 mm dia. Pipe: Providing & fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work & fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.

28

7436

265.58

... More
Pipe clips for 110 mm dia. Pipe: Providing & fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work & fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.

85

22468

264.34

... More
Demolising work: Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars & disposal of unserviceable material outside site to an unobjectionable place as/ direction of Engineer-in-charge

24.83

57606

2320.05

... More
Demolition of Reinforcement Bars: Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineer-in-charge.

82.75

65392

790.24

... More
Hard Rock (Blasting Prohibited) chiesel/pneumatic drilling: Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed.

31.13

30788

989.04

... More
PCC for laying drainage pipe: Providing and laying in position ready mixed plain cement concrete, with cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for plain cement concrete work, including pumping of R.M.C. from transit mixer to site of laying & curing, excluding the cost of centering, shuttering finishing including cost of curing, admixtures in recommended proportions as per IS:9109 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of engineer in charge, ALL WORKS UPTO PLINTH LEVEL. Less cement used as per design mix (if any) will be recoverable separately. No extra payment against extra cement if used shall be payable.

1.25

9039

7231.67

... More
C&S for RCC in foundations,footings,bases of column: Centering and shuttering including strutting, propping etc. and removal of form work for RCC

10

2607

260.73

... More
PVC Drainage Pipe (110 mm ): Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion, Single socketed pipes.

150

41881

279.21

... More
PVC Drainage Pipe (160 mm ): Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion, Single socketed pipes.

85.8

63487

739.95

... More
PVC Drainage Pipe (75 mm ): Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion, Single socketed pipes.

18

3313

184.06

... More
M-15 grade plain cement concrete. (cement content considered @ 240 kg. /cum): Providing and laying in position ready mixed plain cement concrete, with cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for plain cement concrete work, including pumping of R.M.C. from transit mixer to site of laying & curing, excluding the cost of centering, shuttering finishing including cost of curing, admixtures in recommended proportions as per IS:9109 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of engineer in charge, ALL WORKS UPTO PLINTH LEVEL. Less cement used as per design mix (if any) will be recoverable separately. No extra payment against extra cement if used shall be payable.

2.64

19091

7231.67

... More
i) Foundations,footings,bases of column: Centering and shuttering including strutting, propping etc. and removal of form work for:

21.1

5501

260.73

... More
Refilling of Excavated Material: Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, within premises and lift upto 1.5m

13.19

2651

201.04

... More
RCC M 30 Slab: Providing and laying in position ready mixed M-30 grade concrete for reinforced cement concrete work using cement content as per approved design mix manufactured in fully automatic batching plant & transported to site of work in transit mixer for all leads having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering, finishing & reinforcement including cost of admixtures in recommended proportions as per IS:9109 to accelerate/ retard setting of concrete, improve workability without impairing strength & durability as per direction of Engineer-in-charge (Note :- Cement content considered in this item is @ 330 kg/cum. Less cement used as per design mix (if any) will be recoverable separately. No extra payment against extra cement if used shall be payable.

9

69761

7751.24

... More
TMT bars Fe - 500: Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels

353.25

26995

76.42

... More
Disposal of Excavated Material: Extra for levelling & neatly dressing of disposed soil completely as directed by engineer in charge

2.11

128

60.72

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, within premises and lift upto 1.5m

12.18

2448

201.04

... More
RCC M30: Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work using cement content as per approved design mix manufactured in fully automatic batching plant & transported to site of work in transit mixer for all leads having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering, finishing & reinforcement including cost of admixtures in recommended proportions as per IS:9109 to accelerate/ retard setting of concrete, improve workability without impairing strength & durability as per direction of Engineer-in-charge (Note :- Cement content considered in this item is @ 330 kg/cum. Less cement used as per design mix (if any) will be recoverable separately. No extra payment against extra cement if used shall be payable.

15.83

121691

7687.4

... More
Extra for providing richer mixes at all floor levels. Note:- Less cement over the specified cement content used is recoverable separately. No extra payment against extra cement if used shall be payable

15.83

1010

63.83

... More
Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786: Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels

621.33

47482

76.42

... More
Clearing grass and removal of the rubbish outside site premises and at an unobjectionable place.

147

861

5.86

... More
Lift 0.0 To 1.5 m Hard Rock (Blasting Prohibited) chiesel/pneumatic drilling: Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed.

103.05

101920

989.04

... More
Lift 1.5 To 3.0 m Hard Rock (Blasting Prohibited) chiesel/pneumatic drilling: Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed.

59.58

63857

1071.79

... More
Brick Work for recharge pit: Brick work in Cement mortar 1:4 (1 cement: 4 coarse sand) in superstructure in all shapes & sizes in superstructure ABOVE PLINTH & UP TO FLOOR V LEVEL

32.82

234594

7147.91

... More
Demolition of RCC Work: Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars & disposal of unserviceable material outside site to an unobjectionable place as/ direction of Engineer-in-charge

15.28

35450

2320.05

... More
Boulders - 5 cm to 20 cm: Supplying, filling, spreading & levelling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.

21.23

25777

1214.21

... More
Gravels - 5 mm to 10 mm: Supplying, filling, spreading & levelling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.

10.65

12931

1214.21

... More
Gravels - 1.5 mm to 2 mm: Supplying, filling, spreading & levelling gravels of size range 1.5 mm to 2 mm, in the recharge pit, over gravel layer for all leads & lifts, all complete as per direction of Engineer-in-charge.

4.22

5123

1214.21

... More
Precast RCC cover: Providing and fixing precast RCC cover on recharge pit

12

62544

5212.02

... More
Refilling of Excavated Material: Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, within premises and lift upto 1.5m

76.94

15468

201.04

... More
Disposal of Excavated Material: Extra for levelling & neatly dressing of disposed soil completely as directed by engineer in charge

85.69

5203

60.72

... More
‘Rainy’ FL-Series Dual Intensity Filters Rainy Filter FL-300

14

231355

16525.42

... More
‘Rainy’ FL-Series Dual Intensity Filters Rainy Filter FL-150

4

36779

9194.92

... More
‘Rainy’ FL-Series Dual Intensity Filters Rainy Filter FL-80

1

7203

7203.39

... More
GST @ 18%

1

318136

318136.83



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.